Guide to Microplate Readers a One-Stop Solution for Your Microplate Detection Needs Choose the Microplate Reader That Best Suits Your Research Needs

Total Page:16

File Type:pdf, Size:1020Kb

Load more

Guide to microplate readers A one-stop solution for your microplate detection needs Choose the microplate reader that best suits your research needs ™ Thermo Scientific microplate readers Fluoroskan FL provide flexibility, performance, and Multiskan FC Multiskan SkyHigh Fluoroskan Luminoskan fluorometer and ease of use for a variety of microplate Considerations photometer spectrophotometer fluorometer luminometer luminometer Varioskan LUX scanning multimode reader Absorbance, fluorescence assays. Whether you need to Fluorescence, Applications Absorbance Fluorescence Luminescence Optional: time-resolved fluorescence (TRF), luminescence measure fluorescence, absorbance, luminescence, AlphaScreen readout luminescence, or time-resolved Absorbance and fluorescence excitation: 200–1,000 nm fluorescence, or perform AlphaScreen™ Fluorescence emission: 370–840 nm assays, we offer a microplate reader Fluorescence: Luminescence: 360–670 nm solution to meet the needs of your excitation: 320– specific workflow. With a portfolio of Excitation: 320– 700 nm; TRF excitation: fixed to 334 nm Wavelength range 340–850 nm 200–1,000 nm 700 nm; emission: 270–670 nm emission: 360–670 nm (spectral scanning 200–840 nm) dedicated and modular, upgradeable 360–800 nm TRF emission: 400–700 nm Luminescence: multimode readers, we also offer (spectral scanning 270–840 nm) solutions that fit your current budget 270–670 nm AlphaScreen excitation: fixed to 680 nm with options to meet your lab’s AlphaScreen emission: 400–660 nm future needs. Monochromator for UV-Vis absorbance Not required for most and fluorescence intensity Thermo Scientific plate readers Wavelength selection Filters Monochromator Filters applications Filters Filters can be used when necessary Filters for luminescence when necessary, TRF, have a number of features to AlphaScreen assays help you save time and maximize ™ ™ Thermo Scientific µDrop 6–1,536 wells productivity, including: 96 wells and µDrop™ Duo Plates, Plate format 6–384 wells 6–384 wells 6–384 wells (fluorometry, TRF, luminometry, AlphaScreen assays) (384 wells optional) 6-48 well plates*, 96 and • Auto-calibration 384 well plates µDrop and µDrop Duo Plates/6–384 wells (absorbance) Incubation Optional Yes Yes Yes Yes Yes • Easy export to Microsoft™ Excel™ format Shaking Yes Yes Yes Yes Yes Yes Dispensers No No Optional (to three)** Optional (to three)** Optional (to three)** Optional (to two) • Automation readiness with Top (standard) robot compatibility Top/bottom reading NA NA Top/bottom† Top Top/bottom† Bottom (optional)† • No limit to the number of computers Cuvettes No Optional No No No With μDrop Plate on which you can install the intuitive Gas control module No No No No No Optional Thermo Scientific™ SkanIt™ Software • Ready-to-use protocols available in an extensive online protocol library For more information, go to thermofisher.com/platereaders * Maximum plate height with lid 19.5 mm. ** Third dispenser requires additional installation. † Instruments with bottom-read capabilities feature multilocation reads per well. 2 Fluoroskan FL Multiskan FC Multiskan SkyHigh Fluoroskan Luminoskan fluorometer and Considerations photometer spectrophotometer fluorometer luminometer luminometer Varioskan LUX scanning multimode reader Absorbance, fluorescence Fluorescence, Applications Absorbance Fluorescence Luminescence Optional: time-resolved fluorescence (TRF), luminescence luminescence, AlphaScreen readout Absorbance and fluorescence excitation: 200–1,000 nm Fluorescence emission: 370–840 nm Fluorescence: Luminescence: 360–670 nm excitation: 320– Excitation: 320– 700 nm; TRF excitation: fixed to 334 nm Wavelength range 340–850 nm 200–1,000 nm 700 nm; emission: 270–670 nm emission: 360–670 nm (spectral scanning 200–840 nm) 360–800 nm TRF emission: 400–700 nm Luminescence: (spectral scanning 270–840 nm) 270–670 nm AlphaScreen excitation: fixed to 680 nm AlphaScreen emission: 400–660 nm Monochromator for UV-Vis absorbance Not required for most and fluorescence intensity Wavelength selection Filters Monochromator Filters applications Filters Filters can be used when necessary Filters for luminescence when necessary, TRF, AlphaScreen assays ™ ™ Thermo Scientific µDrop 6–1,536 wells 96 wells and µDrop™ Duo Plates, Plate format 6–384 wells 6–384 wells 6–384 wells (fluorometry, TRF, luminometry, AlphaScreen assays) (384 wells optional) 6-48 well plates*, 96 and 384 well plates µDrop and µDrop Duo Plates/6–384 wells (absorbance) Incubation Optional Yes Yes Yes Yes Yes Shaking Yes Yes Yes Yes Yes Yes Dispensers No No Optional (to three)** Optional (to three)** Optional (to three)** Optional (to two) Top (standard) Top/bottom reading NA NA Top/bottom† Top Top/bottom† Bottom (optional)† Cuvettes No Optional No No No With μDrop Plate Gas control module No No No No No Optional * Maximum plate height with lid 19.5 mm. ** Third dispenser requires additional installation. † Instruments with bottom-read capabilities feature multilocation reads per well. 3 A range of microplate readers for maximum flexibility and performance To measure absorbance • Fast operation: full spectrum (200–1,000 nm) of a well Thermo Scientific™ Multiskan™ FC is obtained in less than 10 seconds and a full 96-well Microplate Photometer microplate is read in 6 seconds A robust and reliable filter-based • Access to Connect or Microsoft™ OneDrive™ cloud-based instrument that can be used for a tools allows you to securely store, access, share, and wide variety of research and routine manage data remotely (touchscreen models) applications. It can be used as a stand-alone instrument or under PC control with intuitive thermofisher.com/multiskanskyhigh SkanIt Software. To measure fluorescence • Wide variety of applications, including ELISAs, endotoxin Thermo Scientific™ Fluoroskan™ assays, cytotoxicity assays, and growth curves Microplate Fluorometer • Shaking and incubation up to 50°C for Featuring excellent optical performance, temperature-sensitive assays the Fluoroskan Microplate Fluorometer is ideal for life science research applications • Proven performance and reliable day-to-day results such as fluorometric protein and enzyme studies, molecular through patented optical design and self-diagnostics interaction studies, and nucleic acid quantification, as well thermofisher.com/multiskanfc as reporter gene, fluorometric kinase, immunological, and cell-based assays. Thermo Scientific™ Multiskan™ • High sensitivity for both top and bottom reading SkyHigh Microplate • Onboard dispensers for precise initiation of Spectrophotometer kinetic reactions The Multiskan SkyHigh Microplate Spectrophotometer is easy to use • Can be equipped with up to three reagent dispensers for for any photometric or turbidimetric use during fast kinetic assays, such as Ca2+ flux assays research application, especially nucleic acid and protein thermofisher.com/fluoroskan analysis. It offers an optional easy-to-use graphic touchscreen user interface and multiple connectivity To measure luminescence options (USB, computer, or cloud). Thermo Scientific™ Luminoskan™ • Allows kinetic, spectral, and endpoint measurements for Microplate Luminometer a variety of applications Useful for a variety of luminometric research applications, the Luminoskan • Separates optimized measurement modes for absorption Microplate Luminometer is a compact and turbidimetric measurements and robust instrument offering plate format versatility, • Fast reading speed essential for kinetic applications fast reading speeds, and up to three dispensers. The Luminoskan luminometer provides simplicity and • Available in three different configurations: 1) touchscreen, reliability for increased efficiency of workflows. 2) cuvette and touchscreen, and 3) operated only with SkanIt PC Software • Fast reading speed essential for kinetic applications • Reads µDrop and µDrop Duo plates for microvolume • Onboard dispensers for precise initiation of analysis of DNA, RNA, and protein kinetic reactions • Models with a touchscreen have an easy-to-use interface • Capable of reading a 96-well plate in just 18 seconds, for stand-alone use, including ready-made protocols for essential for kinetic applications such as enzyme kinetic UV-based nucleic acid and protein quantification as well studies and phagocytosis assays as colorimetric protein quantification thermofisher.com/luminoskan 4 To measure fluorescence and luminescence Software for readout Thermo Scientific™ Fluoroskan™ FL Microplate SkanIt Software Fluorometer and Luminometer The intuitive interface of our updated SkanIt Software Featuring excellent optical performance, will guide you through the measurement process to help the Fluoroskan FL Microplate you get the results you need. With SkanIt Software, you Fluorometer and Luminometer is ideal have full control over the instrument settings for all your for fluorometric and luminometric Thermo Scientific microplate readers. SkanIt Software assays in life science research. The is available in two editions. The research edition is for Fluoroskan FL fluorometer and luminometer offers plate scientists working in life science research, and the drug format versatility, fast plate reading speeds, and up to discovery edition provides features to help you comply with three dispensers. the requirements of FDA 21 CFR Part 11. • High sensitivity for both top and bottom reading SkanIt Software makes microplate reading easy • Fast reading speed essential for kinetic applications SkanIt Software provides excellent usability and flexibility, even for the most challenging
Recommended publications
  • Use of Laboratory Equipement

    Use of Laboratory Equipement

    USE OF LABORATORY EQUIPEMENT C. Laboratory Thermometers Most thermometers are based upon the principle that liquids expand when heated. Most common thermometers use mercury or colored alcohol as the liquid. These thermometers are constructed as that a uniform-diameter capillary tube surmounts a liquid reservoir. To calibrate a thermometer, one defines two reference points, normally the freezing point of water (0°C, 32°F) and the boiling point of water (100°C, 212°F) at 1 tam of pressure (1 tam = 760 mm Hg). Once these points are marked on the capillary, its length is then subdivided into uniform divisions called degrees. There are 100° between these two points on the Celsius (°C, or centigrade) scale and 180° between those two points on the Fahrenheit (°F) scale. °F = 1.8 °C + 32 The Thermometer and Its Calibration This section describes the proper technique for checking the accuracy of your thermometer. These measurements will show how measured temperatures (read from thermometer) compare with true temperatures (the boiling and freezing points of water). The freezing point of water is 0°C; the boiling point depends upon atmospheric pressure but at sea level it is 100°C. Option 1: Place approximately 50 mL of ice in a 250-mL beaker and cover the ice with distilled water. Allow about 15 min for the mixture to come to equilibrium and then measure and record the temperature of the mixture. Theoretically, this temperature is 0°C. Option 2: Set up a 250-mL beaker on a wire gauze and iron ring. Fill the beaker about half full with distilled water.
  • Oristm Cell Migration Assay – Tricoated

    Oristm Cell Migration Assay – Tricoated

    TM Oris Cell Migration Assay – TriCoated Product No.: CMATR1 & CMATR5 96-well, 2-D Assay for Investigating Cell Migration of Adherent Cell Lines on Three Coated Surfaces PROTOCOL & INSTRUCTIONS Table of Contents I. INTRODUCTION .................................................................................................. 2 II. ORISTM PLATE DIMENSIONS .............................................................................. 3 III. MATERIALS PROVIDED ...................................................................................... 3 IV. MATERIALS REQUIRED ...................................................................................... 3 V. CELL MIGRATION ASSAY – TRICOATED PROTOCOL .................................... 4 VI. DATA ACQUISITION ............................................................................................ 6 VII. ORDERING INFORMATION ................................................................................ 7 VIII. TERMS & CONDITIONS ...................................................................................... 7 Appendix I: Determining Optimal Cell Seeding Concentration ............................. 8 Appendix II: Determining Optimal Fluorescence Microplate Reader Settings ...... 8 Platypus Technologies, LLC 5520 Nobel Drive, Suite 100, Madison, WI 53711 Toll Free: 866.3296.4455 Phone: 608.237.1270 Fax: 608.237.1271 www.platypustech.com SP0034.06 Oris™ CELL MIGRATION ASSAY – TRICOATED I. INTRODUCTION The Oris™ Cell Migration Assay – TriCoated is a reproducible, sensitive, and flexible
  • Laboratory Glassware N Edition No

    Laboratory Glassware N Edition No

    Laboratory Glassware n Edition No. 2 n Index Introduction 3 Ground joint glassware 13 Volumetric glassware 53 General laboratory glassware 65 Alphabetical index 76 Índice alfabético 77 Index Reference index 78 [email protected] Scharlau has been in the scientific glassware business for over 15 years Until now Scharlab S.L. had limited its sales to the Spanish market. However, now, coinciding with the inauguration of the new workshop next to our warehouse in Sentmenat, we are ready to export our scientific glassware to other countries. Standard and made to order Products for which there is regular demand are produced in larger Scharlau glassware quantities and then stocked for almost immediate supply. Other products are either manufactured directly from glass tubing or are constructed from a number of semi-finished products. Quality Even today, scientific glassblowing remains a highly skilled hand craft and the quality of glassware depends on the skill of each blower. Careful selection of the raw glass ensures that our final products are free from imperfections such as air lines, scratches and stones. You will be able to judge for yourself the workmanship of our glassware products. Safety All our glassware is annealed and made stress free to avoid breakage. Fax: +34 93 715 67 25 Scharlab The Lab Sourcing Group 3 www.scharlab.com Glassware Scharlau glassware is made from borosilicate glass that meets the specifications of the following standards: BS ISO 3585, DIN 12217 Type 3.3 Borosilicate glass ASTM E-438 Type 1 Class A Borosilicate glass US Pharmacopoeia Type 1 Borosilicate glass European Pharmacopoeia Type 1 Glass The typical chemical composition of our borosilicate glass is as follows: O Si 2 81% B2O3 13% Na2O 4% Al2O3 2% Glass is an inorganic substance that on cooling becomes rigid without crystallising and therefore it has no melting point as such.
  • PML Brochure

    PML Brochure

    PHYSICAL MEASUREMENT LABORATORY Gauging nature on all scales NIST.GOV/PML PHYSICAL MEASUREMENT LABORATORY (PML) The Physical Measurement Laboratory (PML), a major frequency, electricity, temperature, humidity, pressure operating unit of the National Institute of Standards and vacuum, liquid and gas flow, and electromag- and Technology (NIST), sets the definitive U.S. standards netic, optical, acoustic, and ionizing radiation. PML for nearly every kind of measurement in modern life, collaborates directly with industry, universities, profes- sometimes across more than 20 orders of magni- sional and standards-setting organizations, and other tude. PML is a world leader in the science of physical agencies of government to ensure accuracy and to measurement, devising procedures and tools that make solve problems. It also supports research in many continual progress possible. Exact measurements are fields of urgent national importance, such as manu- absolutely essential to industry, medicine, the research facturing, energy, health, law enforcement and community, and government. All of them depend on homeland security, communications, military defense, PML to develop, maintain, and disseminate the official electronics, the environment, lighting and display, standards for a wide range of quantities, including radiation, remote sensing, space exploration, length, mass, force and shock, acceleration, time and and transportation. IMPACTS ❱ Provides 700 kinds of calibration services ❱ Numerous special testing services NIST.GOV/PML | 2 NIST.GOV/PML
  • Chemostat Culture for Yeast Experimental Evolution

    Chemostat Culture for Yeast Experimental Evolution

    Downloaded from http://cshprotocols.cshlp.org/ at Cold Spring Harbor Laboratory Library on August 9, 2017 - Published by Cold Spring Harbor Laboratory Press Protocol Chemostat Culture for Yeast Experimental Evolution Celia Payen and Maitreya J. Dunham1 Department of Genome Sciences, University of Washington, Seattle, Washington 98195 Experimental evolution is one approach used to address a broad range of questions related to evolution and adaptation to strong selection pressures. Experimental evolution of diverse microbial and viral systems has routinely been used to study new traits and behaviors and also to dissect mechanisms of rapid evolution. This protocol describes the practical aspects of experimental evolution with yeast grown in chemostats, including the setup of the experiment and sampling methods as well as best laboratory and record-keeping practices. MATERIALS It is essential that you consult the appropriate Material Safety Data Sheets and your institution’s Environmental Health and Safety Office for proper handling of equipment and hazardous material used in this protocol. Reagents Defined minimal medium appropriate for the experiment For examples, see Protocol: Assembly of a Mini-Chemostat Array (Miller et al. 2015). Ethanol (95%) Glycerol (20% and 50%; sterile) Yeast strain of interest Equipment Agar plates (appropriate for chosen strain) Chemostat array Assemble the apparatus as described in Miller et al. (2013) and Protocol: Assembly of a Mini-Chemostat Array (Miller et al. 2015). Cryo deep-freeze labels Cryogenic vials Culture tubes Cytometer (BD Accuri C6) Glass beads, 4 mm (sterile; for plating yeast cells) Glass cylinder Kimwipes 1Correspondence: [email protected] © 2017 Cold Spring Harbor Laboratory Press Cite this protocol as Cold Spring Harb Protoc; doi:10.1101/pdb.prot089011 559 Downloaded from http://cshprotocols.cshlp.org/ at Cold Spring Harbor Laboratory Library on August 9, 2017 - Published by Cold Spring Harbor Laboratory Press C.
  • Increasing the Reproducibility of Serial Dilutions

    Increasing the Reproducibility of Serial Dilutions

    Increasing the Reproducibility of Serial Dilutions Michael Beier* Abstract Pipetting serial dilutions reproducibly can be difficult because it is a time consuming and consequently error prone methodology, especially in 384 well plates. Based upon the assumption that your pipettes are properly maintained and calibrated, the human influence has the largest impact on pipetting results. Observing good pipetting practice helps immensely to improve reproducibility and accuracy. In this article we focus on a selection of good pipetting techniques, which if maintained offer the best chance of increasing and maintaining the reproducibility of your serial dilutions. Mixing is a key component of dilution protocols and in this article we additionally discuss different mixing parameters to help you achieve a homogenous sample. To maximize consistency of dilution assays, automating the process offers many benefits. For ensuring highly reproducible serial dilutions we outline what features an automated pipetting system should have and introduce the VIAFLO ASSIST – a product purpose designed for this task. Introduction to good pipetting practice Good pipetting practice describes guidelines covering the basic techniques to ensure that the pipettes are used in an optimal and reproducible manner. Before preparing your assay, you should perform a pre-wet of your pipette tips. Do this by aspirating and dispensing the full volume 2-3 times. This procedure not only equilibrates temperature differences between liquid and tip but also humidifies the dead air space inside the pipette and tip. Neglecting to perform a pre-wet can result in a smaller delivery volume in the first few dispenses, thereby introducing errors into your subsequent dilution steps.
  • Evos Cell Imaging Analysis Systems

    Evos Cell Imaging Analysis Systems

    Imaging, labeling, and detection solutions Microscopy | High-content analysis | Cell counting | Plate reading Minimizing the complexities of cellular analysis Our cellular analysis product portfolio combines the strengths of Invitrogen™ fluorescent reagents and a complete line of versatile analysis instrumentation. Select from a line of heavily peer-referenced platforms to make the discoveries that catalyze advances toward your research goals of tomorrow. Invitrogen™ EVOS™ imaging systems Our comprehensive imaging portfolio includes: • Cell imaging systems • Automated cell counting systems • High-content analysis systems Invitrogen™ Countess™ cell counters • Cell imaging reagents • Microplate readers All of our analysis systems are designed to work together— Thermo Scientific™ CellInsight™ from the initial cell culture check to more complex analyses. high-content analysis systems Discover more about your samples with automated cell counting, long-term live-cell imaging, automated multiwell plate scanning, and phenotypic screening. Thermo Scientific™ Varioskan™ LUX multimode plate reader Contents Microscopy Compact and portable imaging systems 4 EVOS imaging systems at a glance 5 EVOS M7000 Imaging System 6 Live-cell imaging with the Onstage Incubator 8 Image analysis with Celleste software 10 EVOS M5000 Imaging System 12 EVOS FLoid Imaging Station 14 EVOS XL Core Imaging System 15 EVOS vessel holders and stage plates 16 The power of LED illumination 17 EVOS objectives 18 Fluorophore selection guide 20 High-content analysis CellInsight high-content analysis platforms 22 CellInsight CX7 LZR High-Content Analysis Platform 24 CellInsight CX5 High-Content Screening Platform 25 HCS Studio Cell Analysis Software 26 Store Image and Database Management Software 27 Cell counting Countess II Automated Cell Counters 28 Plate reading Microplate readers 30 Microscopy Compact and portable imaging systems Now you can have an easy-to-use cell imaging platform From intimate hands-on demonstrations to presentations of where you want it and when you want it.
  • BROOKFIELD DIAL READING VISCOMETER with Electronic Drive

    BROOKFIELD DIAL READING VISCOMETER with Electronic Drive

    BROOKFIELD DIAL READING VISCOMETER with Electronic Drive Operating Instructions Manual No. M00-151-I0614 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY with offices in : Boston • Chicago • London • Stuttgart • Guangzhou BROOKFIELD ENGINEERING LABORATORIES, INC. 11 Commerce Boulevard, Middleboro, MA 02346 USA TEL 508-946-6200 or 800-628-8139 (USA excluding MA) FAX 508-946-6262 INTERNET http://www.brookfieldengineering.com TABLE OF CONTENTS I. INTRODUCTION .....................................................................................5 I.1 Components .......................................................................................................5 I.2 Utilities ................................................................................................................6 I.3 Specifications .....................................................................................................6 I.4 Set-Up ................................................................................................................7 I.5 IQ, OQ, PQ .........................................................................................................7 I.6 Safety Symbols and Precautions .......................................................................8 I.7 Cleaning .............................................................................................................8 II. GETTING STARTED ..............................................................................9 II.1 Operation ...........................................................................................................9
  • ELISA Plate Reader

    ELISA Plate Reader

    applications guide to microplate systems applications guide to microplate systems GETTING THE MOST FROM YOUR MOLECULAR DEVICES MICROPLATE SYSTEMS SALES OFFICES United States Molecular Devices Corp. Tel. 800-635-5577 Fax 408-747-3601 United Kingdom Molecular Devices Ltd. Tel. +44-118-944-8000 Fax +44-118-944-8001 Germany Molecular Devices GMBH Tel. +49-89-9620-2340 Fax +49-89-9620-2345 Japan Nihon Molecular Devices Tel. +06-6399-8211 Fax +06-6399-8212 www.moleculardevices.com ©2002 Molecular Devices Corporation. Printed in U.S.A. #0120-1293A SpectraMax, SoftMax Pro, Vmax and Emax are registered trademarks and VersaMax, Lmax, CatchPoint and Stoplight Red are trademarks of Molecular Devices Corporation. All other trademarks are proprty of their respective companies. complete solutions for signal transduction assays AN EXAMPLE USING THE CATCHPOINT CYCLIC-AMP FLUORESCENT ASSAY KIT AND THE GEMINI XS MICROPLATE READER The Molecular Devices family of products typical applications for Molecular Devices microplate readers offers complete solutions for your signal transduction assays. Our integrated systems γ α β s include readers, washers, software and reagents. GDP αs AC absorbance fluorescence luminescence GTP PRINCIPLE OF CATCHPOINT CYCLIC-AMP ASSAY readers readers readers > Cell lysate is incubated with anti-cAMP assay type SpectraMax® SpectraMax® SpectraMax® VersaMax™ VMax® EMax® Gemini XS LMax™ ATP Plus384 190 340PC384 antibody and cAMP-HRP conjugate ELISA/IMMUNOASSAYS > nucleus Single addition step PROTEIN QUANTITATION cAMP > λEX 530 nm/λEM 590 nm, λCO 570 nm UV (280) Bradford, BCA, Lowry For more information on CatchPoint™ assay NanoOrange™, CBQCA kits, including the complete procedure for this NUCLEIC ACID QUANTITATION assay (MaxLine Application Note #46), visit UV (260) our web site at www.moleculardevices.com.
  • Dynapro® Plate Reader™ II User's Guide

    Dynapro® Plate Reader™ II User's Guide

    DynaPro® Plate Reader™ II User’s Guide M3101 Rev C Copyright © 2014, Wyatt Technology Corporation WYATT TECHNOLOGY Corp., makes no warranties, either express or implied, regarding this instrument, computer software package, its merchantability or its fitness for any particular purpose. The software is provided “as is,” without warranty of any kind. Furthermore, Wyatt Technology does not warrant, guarantee, or make any representations regarding the use, or the results of the use, of the software or written materials in terms of correctness, accuracy, reliability, currentness, or otherwise. The exclusion of implied warranties is not permitted by some states, so the above exclusion may not apply to you. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Wyatt Technology Corporation. ® DynaPro, DYNAMICS, Wyatt Technology, and its logo are registered trademarks of the Wyatt Technology Corporation. ™ Plate Reader and Protein Solutions are trademarks of Wyatt Technology Corporation. A variety of U.S. and foreign patents have been issued and/or are pending on various aspects of the apparatus and methodology implemented by this instrumentation. Table of Contents Chapter 1: Introduction Overview ............................................................................................................................6 The Instrument ............................................................................................................6
  • Information Technology Laboratory Technical Accomplishments

    Information Technology Laboratory Technical Accomplishments

    CONTENTS Director’s Foreword 1 ITL at a Glance 4 ITL Research Blueprint 6 Accomplishments of our Research Program 7 Foundation Research Areas 8 Selected Cross-Cutting Themes 26 Industry and International Interactions 36 Publications 44 NISTIR 7169 Conferences 47 February 2005 Staff Recognition 50 U.S. DEPARTMENT OF COMMERCE Carlos M. Gutierrez, Secretary Technology Administration Phillip J. Bond Under Secretary of Commerce for Technology National Institute of Standards and Technology Hratch G. Semerjian, Jr., Acting Director About ITL For more information about ITL, contact: Information Technology Laboratory National Institute of Standards and Technology 100 Bureau Drive, Stop 8900 Gaithersburg, MD 20899-8900 Telephone: (301) 975-2900 Facsimile: (301) 840-1357 E-mail: [email protected] Website: http://www.itl.nist.gov INFORMATION TECHNOLOGY LABORATORY D IRECTOR’S F OREWORD n today’s complex technology-driven world, the Information Technology Laboratory (ITL) at the National Institute of Standards and Technology has the broad mission of supporting U.S. industry, government, and Iacademia with measurements and standards that enable new computational methods for scientific inquiry, assure IT innovations for maintaining global leadership, and re-engineer complex societal systems and processes through insertion of advanced information technology. Through its efforts, ITL seeks to enhance productivity and public safety, facilitate trade, and improve the Dr. Shashi Phoha, quality of life. ITL achieves these goals in areas of Director, Information national priority by drawing on its core capabilities in Technology Laboratory cyber security, software quality assurance, advanced networking, information access, mathematical and computational sciences, and statistical engineering. utilizing existing and emerging IT to meet national Information technology is the acknowledged engine for priorities that reflect the country’s broad based social, national and regional economic growth.
  • Wellwash and Wellwash Versa Washers for Expanded Functionality Ease of Use, Convenience, and Versatility for Washing Microplates in ELISA Assays

    Wellwash and Wellwash Versa Washers for Expanded Functionality Ease of Use, Convenience, and Versatility for Washing Microplates in ELISA Assays

    Wellwash and Wellwash Versa washers for expanded functionality Ease of use, convenience, and versatility for washing microplates in ELISA assays Reliable and easy-to-use Thermo Scientifi ™c Wellwash™ microplate strip washers provide secure washing performance for routine and research ELISA applications. Wellwash washers feature a large color display with graphical user interface, local language versions, and non-pressurized bottles for optimal ease of use, convenience, and safety. The Thermo Scientifi ™c Wellwash™ Microplate Washer is the In addition, the Wellwash Versa washer off ers: basic model for washing 96-well plates. It is intended for • Very fast and simple instrument setup and use with use when only a few similar assays are run routinely. The color-coded tube fi ttings and liquid-level sensor cables Thermo Scientifi ™c Wellwash™ Versa Microplate Washer is the advanced model for 96-well plates that can also wash • Wide selection of wash heads for 96-well plates and cells and 384-well plates, off ering the enhanced fl exibility 1 x 16 wash head for 384-well plates needed for research use. • Specially designed 2 x 8-cell wash head for gentle washing of cells in a 96-well plate Wellwash and Wellwash Versa washers off er: • Easy setup of wash protocols through a large color • Two wash bottles and one rinse bottle for screen and a visual user interface increased fl exibility • A sweep mode to ensure an extremely low residual • Easy connection to automation systems volume in the well, resulting in excellent washing performance and reliable ELISA results Convenient and simple to use • Adjustable wash parameters, such as dispense and The large color screen makes Wellwash and Wellwash aspiration height and aspiration speed, for optimal Versa washers very easy and convenient to use.