Gas Fired Low Intensity Heaters Operating Principles of Two-Stage and Modulating Systems This white paper presents the operational characteristics of two-stage and modulating infrared heaters. Data presented represents an in-depth analysis of industry practices and on-site testing at our approved laboratory.

A Detroit Radiant Products Company White Paper December 2008 • LTL002.1109 • Rev 1.1

Detroit Radiant Products Company 21400 Hoover Road Warren, MI 48089 Tel: 586.756.0950 www.reverberray.com

© 2009 Detroit Radiant Products Co. A Detroit Radiant Products Company White Paper

Introduction

Traditional sizing of a building’s has typically been based on the maximum or worst-case heat loss analysis. However, the calculated maximum heat load is normally encountered for only 1-2% of the annual heating hours.

In an era of extreme concern for energy consumption, more efficient technologies have been developed. One proven technology entails adjusting heat output to perform to the changing demands of the environment. Significant energy savings and improved equipment longevity can be achieved by varying the flow of gas or both gas and air to the appliance.

A two-stage heater’s adjusts only the gas flow to the burner allowing for operation Infrared tube heaters gradually decrease in in a high and a low fire mode. During high fire operation, the gas and air mixture remains temperature over the length equivalent to that achieved while in single-stage operation. During low fire operation, gas of the heater. A well-designed flow through the burner is reduced while airflow remains a constant. This results in reduced tube heater can minimize the total output differential. fuel consumption and costs. In addition, an elongated flame is maintained, resulting in continued comfort levels during both firing stages.

In contrast, a modulating heater varies the amount of both air and gas flow to the burner to achieve this varied heat output. Unfortunately, reducing airflow to the combustion process of an infrared heater compromises the heat output pattern and also slows responsiveness. This results in inferior heat distribution and ultimately sacrifices comfort levels in the space.

Applicable Definitions

Two-Stage Operation: The ability of an infrared heater to operate at two predetermined rates; typically 65% (low fire) and 100% (high fire) of the maximum firing rate.

Modulation: The ability of an infrared heater to operate and adjust output according to demand. Adjustments occur between an upper and a lower limit; typically 65% (minimum) and 100% (maximum) of the maximum firing rate.

Radiant Efficiency:The radiant heat energy emitted by an appliance divided by the total energy available. A crucial factor in determining the effective performance of an infrared heater.

Thermal Efficiency: The total useful heat energy captured by an appliance divided by While commonly used as a measure of the efficiency of the heating value of the fuel supplied. A measurement of three factors which combine to heating appliances, thermal quantify the total energy available to the appliance. efficiency can be misleading when applied to an infrared Radiant Flux Density: A measurement of energy leaving a source, divided by a unit of heater. A common method time multiplied by an area of coverage. This is often interpreted as intensity, radiant output to achieve high thermal efficiencies is to allow an or coverage. Example: BTU/h per sq. ft. infrared heater to cool below the condensing point, thereby emitting very little radiant heat. A Detroit Radiant Products Company White Paper

Performance Comparison Operating Principles of Two-Stage and Modulating Systems

Temperature Curve Graph Response and Cycle Graph Typical response time of a low intensity infrared heater is 1000 90°

180 seconds. However, when e modulating, the response time will inevitably lag as a result Temp. Setpoint emperatur of the core design principle T

that prioritizes thermal ace efficiency. ube Surf T

0 65° 0 Tube Length 40 Time This graph depicts the temperature differential of Here we see the response time of a two-stage, the radiant tube exchangers over the length of the single-stage, and modulating heater starting from heater while operating at reduced output. the same initial conditions.

Single Stage Two-Stage Modulation

Two-Stage Flux Density Pattern Modulating Flux Density Pattern When speed is slowed in the combustion process, the burner flame is shortened. A shorter flame negatively impacts heater performance and comfort levels.

A two-stage heater operating at low fire has a A modulating heater operating at reduced output greater coverage and comfort area when compared results in a diminished comfort zone because of a to a modulating heater because of a longer flame. shortened flame and uneven heat pattern.

Product Comparison Chart TOPIC TWO-STAGE MODULATION Burner Flame Length Longer flame utilizing more air. Shorter flame utilizing less air. Controls Simple with a variety of options. Complicated and costly.* Emissions Lower CO2 and NOX. Higher emissions. Efficiencies Targets higher radiant efficiencies. Targets higher thermal efficiencies. Heat Distribution More even with higher exhaust temperatures. Less even with cooler exhaust temperatures. Heat Recovery Fast recovery. Slow ramp-up period. Product Life Even flame enhances longevity. Hot spots reduce longevity. Tube Temperatures Higher downstream tube temperatures. Hotter first tube section produces uneven output.

* Some models in the market require a specific controller in order to enable the operation of modulation. A Detroit Radiant Products Company White Paper

Frequently Asked Questions (FAQ’s)

Q: Why is modulation a technology not well suited for infrared heaters? A: Modulation was developed primarily to improve comfort levels in the space by reducing on/off cycles and optimizing thermal efficiencies. However, several key factors negate the usefulness of this technology when applied to a low intensity infrared heater. They include:

1. The reduced flame length caused by slowing air speed decreases comfort levels. This differential in the heat flux pattern is prominent because of the lack of an intermediary object in the transfer of thermal energy.

2. The maximum advantages of modulation occur when there is a greater turndown in energy input over a traditional two-stage unit. For example, some and residential modulating can modulate significantly (70% turndown) below their maximum input. However, when modulation is applied to an infrared heater, input reduction is limited by a fixed exchanger length in order to avoid condensation.

3. Ramp up and response time is reduced in infrared heaters utilizing modulation technology. Rather than focusing on heat recovery, modulation systems chase a false moving target of obtaining optimal thermal efficiencies, ultimately sacrificing heat recovery and response time. Q: Is two-stage more energy efficient than modulation? A: Two heaters with identical high- and low-limit firing rates will demonstrate similar energy saving benefits regardless of whether they utilize two-stage or modulation technology. Both heaters will prove beneficial over single-stage unitary heaters. Q: Is it true that a two-stage heater has a lower thermal efficiency rating than its modulating counterpart? A: Yes, a small percentage (1%-2%) of thermal efficiency is intentionally sacrificed in order to improve comfort levels, reduce harmful emissions and enhance radiant flux density patterns. Q: Is there a financial benefit to using two-stage versus modulation? A: The initial investment is typically lower with two-stage; therefore, the energy saving payback benefit is realized in a much shorter time period. In addition, the controls required for modulation are more complex and costly, potentially negating the payback benefit of variable output operation. The bottom line: two-stage heaters offer a reduced capital investment, shorter payback period and control simplicity.

Summary

Tests show that both types of heaters operate within a similar minimum and maximum firing range. The added costs and complexities required to modulate a heater within that range, in conjunction with adverse performance characteristics (due to the reduction of air output), call into question the logic of a modulating infrared heater. Re-Verber-Ray® two-stage heaters are proven energy saving appliances with proven product and application related features.

Detroit Radiant Products Company · 21400 Hoover Road · Warren, MI 48089 · 586.756.0950 · www.reverberray.com