Interpreting the Requirements of Articles 500-516 of the NEC®

Total Page:16

File Type:pdf, Size:1020Kb

Interpreting the Requirements of Articles 500-516 of the NEC® Interpreting the Requirements of Articles 500-516 of the NEC® 2017 National Electrical Code® Review A Guide for the Use of Appleton™ Products in Hazardous Locations TABLE OF CONTENTS Introduction 1 General Information 3 NEC® ARTICLES 100, 500 THROUGH 516 – TEXT AND COMMENTARY Article 100 – Definitions 11 Article 500 – Hazardous (Classified) Locations, Class I, II, and III, Divisions 1 and 2 Changes to Article 500 19 500.1 Scope — Articles 500 Through 504 19 500.3 Other Articles 19 500.4 General 19 500.5 Classifications of Locations 19 500.6 Material Groups 22 500.7 Protection Techniques 24 500.8 Equipment 26 500.9 Specific Occupancies 30 Article 501 – Class I Locations Changes to Article 501 31 501.1 Scope 31 501.5 Zone Equipment 31 501.10 Wiring Methods 31 501.15 Sealing and Drainage 35 501.17 Process Sealing 43 501.20 Conductor Insulation, Class I, Divisions 1 and 2 44 501.25 Uninsulated Exposed Parts, Class I, Divisions 1 and 2 44 501.30 Grounding and Bonding, Class I, Divisions 1 and 2 44 501.35 Surge Protection 45 501.100 Transformers and Capacitors 45 501.105 Meters, Instruments, and Relays 45 501.115 Switches, Circuit Breakers, Motor Controllers, and Fuses 47 501.120 Control Transformers and Resistors 47 501.125 Motors and Generators 48 501.130 Luminaires 50 501.135 Utilization Equipment 53 501.140 Flexible Cords, Class I, Divisions 1 and 2 54 501.145 Receptacles and Attachment Plugs, Class I, Divisions 1 and 2 55 501.150 Signaling, Alarm, Remote-Control, and Communications Systems 56 Article 502 – Class II Locations Changes to Article 502 57 502.1 Scope 57 502.5 Explosionproof Equipment 57 502.6 Zone Equipment 57 502.10 Wiring Methods 57 502.15 Sealing, Class II, Divisions 1 and 2 60 502.25 Uninsulated Exposed Parts, Class II, Divisions 1 and 2 60 502.30 Grounding and Bonding, Class II, Divisions 1 and 2 61 502.35 Surge Protection — Class II, Divisions 1 and 2 61 i 2017 CODE REVIEW TABLE OF CONTENTS 502.100 Transformers and Capacitors 61 502.115 Switches, Circuit Breakers, Motor Controllers, and Fuses 62 502.120 Control Transformers and Resistors 62 502.125 Motors and Generators 63 502.128 Ventilating Piping 64 502.130 Luminaires 64 502.135 Utilization Equipment 65 502.140 Flexible Cords — Class II, Divisions 1 and 2 66 502.145 Receptacles and Attachment Plugs 67 502.150 Signaling, Alarm, Remote-Control, and Communications Systems; and Meters, Instruments, and Relays 67 Article 503 – Class III Locations Changes to Article 503 69 503.1 Scope 69 503.5 General 69 503.6 Zone Equipment 70 503.10 Wiring Methods 70 503.25 Uninsulated Exposed Parts, Class III, Divisions 1 and 2 71 503.30 Grounding and Bonding — Class III, Divisions 1 and 2 71 503.100 Transformers and Capacitors — Class III, Divisions 1 and 2 72 503.115 Switches, Circuit Breakers, Motor Controllers, and Fuses — Class III, Divisions 1 and 2 72 503.120 Control Transformers and Resistors — Class III, Divisions 1 and 2 72 503.125 Motors and Generators — Class III, Divisions 1 and 2 72 503.128 Ventilating Piping — Class III, Divisions 1 and 2 72 503.130 Luminaires — Class III, Divisions 1 and 2 72 503.135 Utilization Equipment — Class III, Divisions 1 and 2 73 503.140 Flexible Cords — Class III, Divisions 1 and 2 73 503.145 Receptacles and Attachment Plugs — Class III, Divisions 1 and 2 73 503.150 Signaling, Alarm, Remote-Control, and Local Loudspeaker Intercommunications Systems — Class III, Divisions 1 and 2 74 503.155 Electric Cranes, Hoists, and Similar Equipment — Class III, Divisions 1 and 2 74 503.160 Storage Battery Charging Equipment — Class III, Divisions 1 and 2 74 Article 504 – Intrinsically Safe Systems Changes to Article 504 75 504.1 Scope 75 504.2 Definitions 75 504.3 Application of Other Articles 75 504.4 Equipment 75 504.10 Equipment Installation 75 504.20 Wiring Methods 76 504.30 Separation of Intrinsically Safe Conductors 76 504.50 Grounding 77 504.60 Bonding 78 504.70 Sealing 78 504.80 Identification 78 Article 505 – Zone 0, 1, and 2 Locations Changes to Article 505 79 505.1 Scope 79 ii 2017 CODE REVIEW TABLE OF CONTENTS 505.2 Definitions 79 505.3 Other Articles 80 505.4 General 80 505.5 Classifications of Locations 81 505.6 Material Groups 82 505.7 Special Precaution 83 505.8 Protection Techniques 83 505.9 Equipment 84 505.15 Wiring Methods 88 505.16 Sealing and Drainage 90 505.17 Flexible Cords and Connections 94 505.18 Conductors and Conductor Insulation 95 505.19 Uninsulated Exposed Parts 95 505.20 Equipment Requirements 95 505.22 Increased Safety “e” Motors and Generators 95 505.25 Grounding and Bonding 96 505.26 Process Sealing 96 Article 506 – Zone 20, 21, and 22 Locations for Combustible Dusts or Ignitable Fibers/Flyings Changes to Article 506 99 506.1 Scope 99 506.2 Definitions 99 506.3 Other Articles 100 506.4 General 100 506.5 Classification of Locations 100 506.6 Material Groups 101 506.7 Special Precaution 101 506.8 Protection Techniques 102 506.9 Equipment Requirements 103 506.15 Wiring Methods 104 506.16 Sealing 106 506.17 Flexible Cords 106 506.20 Equipment Installation 106 506.25 Grounding and Bonding 107 Article 510 – Hazardous (Classified) Locations – Specific Changes to Article 510 109 510.1 Scope 109 510.2 General 109 Article 511 – Commercial Garages, Repair and Storage Changes to Article 511 111 511.1 Scope 111 511.2 Definitions 111 511.3 Area Classification, General 111 511.4 Wiring and Equipment in Class I Locations 112 511.7 Wiring and Equipment Installed Above Class I Locations 113 511.8 Underground Wiring 114 iii 2017 CODE REVIEW TABLE OF CONTENTS 511.9 Sealing 114 511.10 Special Equipment 114 511.12 Ground-Fault Circuit-Interrupter Protection for Personnel 115 511.16 Grounding and Bonding Requirements 115 Article 513 – Aircraft Hangers Changes to Article 513 117 513.1 Scope 117 513.2 Definitions 117 513.3 Classification of Locations 117 513.4 Wiring and Equipment in Class I Locations 117 513.7 Wiring and Equipment Not Installed in Class I Locations 117 513.8 Underground Wiring 118 513.9 Sealing 118 513.10 Special Equipment 118 513.12 Ground-Fault Circuit-Interrupter Protection for Personnel 119 513.16 Grounding and Bonding Requirements 119 Article 514 – Motor Fuel Dispensing Facilities Changes to Article 514 121 514.1 Scope 121 514.2 Definition 121 514.3 Classification of Locations 121 514.4 Wiring and Equipment Installed in Class I Locations 126 514.7 Wiring and Equipment Above Class I Locations 126 514.8 Underground Wiring 126 514.9 Sealing 127 514.11 Circuit Disconnects 127 514.13 Provisions for Maintenance and Service of Dispensing Equipment 127 514.16 Grounding and Bonding 127 Article 515 – Bulk Storage Plants Changes to Article 515 129 515.1 Scope 129 515.3 Class I Locations 129 515.4 Wiring and Equipment Located in Class I Locations 129 515.7 Wiring and Equipment Above Class I Locations 129 515.8 Underground Wiring 132 515.9 Sealing 132 515.10 Special Equipment — Gasoline Dispensers 132 515.16 Grounding and Bonding 132 Article 516 – Spray Application, Dipping, Coating, and Printing Processes Using Flammable or Combustible Materials Changes to Article 516 135 516.1 Scope 135 516.2 Definitions 135 516.4 Area Classification for Open Containers 136 516.5 Area Classification for Spray Application Processes 137 516.6 Wiring and Equipment in Class I Locations 140 516.7 Wiring and Equipment Not Within Classified Locations 141 iv 2017 CODE REVIEW TABLE OF CONTENTS 516.10 Special Equipment 141 516.16 Grounding 143 516.18 Area Classification for Temporary Membrane Enclosures 143 516.23 Electrical and Other Sources of Ignition 144 516.29 Classification of Locations 144 516.35 Areas Adjacent to Enclosed Dipping and Coating Processes 146 516.36 Equipment and Containers in Ventilated Areas 146 516.37 Luminaires 146 516.38 Wiring and Equipment Not Within Classified Locations 146 516.40 Static Electric Discharges 147 APPENDIXES Appendix A-1: Class I Flammable Gases And Vapors 149 Appendix A-2: Class II Combustible Dusts 155 Appendix B-1: Applicable Product Standards 159 Appendix B-2: NEMA Enclosure Definitions 161 Appendix B-3: Comparison Between NEMA Enclosure Type Numbers and IEC® Enclosure Classification Designations 162 Appendix C: Standards, Testing and Certification 164 Appendix D: Quick Selection Guide — Equipment for Hazardous Locations 166 Appendix E-1: Lighting and Power Diagrams: Class I, Divisions 1 and 2, Group B; Class I, Zones 1 and 2, Groups IIA, IIB + H2 170 Appendix E-2: Power Diagram: Class I, Division 1, Groups C and D, Class I, Zone 1, Groups IIA, IIB 172 Appendix E-3: Lighting Diagram: Class I, Division 1, Groups C and D; Class 1, Zone 1, Groups IIA and IIB 174 Appendix E-4: Lighting and Power Diagram: Class I, Division 2, Groups C and D; Class I, Zone 2, Groups IIA and IIB 176 Appendix E-5: Power Diagram: Class II, Divisions 1 and 2, Groups E, F and G; Class II, Zones 21 and 22 178 Appendix E-6: Lighting Diagram: Class II, Divisions 1 and 2, Groups E, F and G; Class II, Zones 21 and 22 180 Appendix E-7: Lighting and Power Diagram: Class I, Zone 1; Class I, Zone 2 182 v 2017 CODE REVIEW NOTES vi 2017 CODE REVIEW INTRODUCTION PURPOSE OF THE REVIEW Material taken from the National Electrical Code is reprinted with permission from NFPA 70®-2017, National Electrical Code®, • Assist in interpreting the requirements of Articles 500-516 Copyright © 2016, National Fire Protection Association, Quincy, of the 2017 NEC®.
Recommended publications
  • 2020 National Electrical Code® Style Manual
    2020 NATIONAL ELECTRICAL CODE® STYLE MANUAL 1 FOREWORD August 2020 The National Electrical Code® is used nationally and internationally as the basis for safeguarding persons, buildings, and their contents from hazards arising from the use of electricity. It is vitally important that the text be as explicit as possible, and that maximum consistency be achieved in the language used in the text. The Code contains those provisions considered necessary for safety and thus is widely used as a basis for legal enforcement in the installation of electrical conductors and equipment in buildings and certain other premises (as detailed in the Code itself); this places a major responsibility on those involved in the preparation of document text to use forms of expression that promote uniform interpretation. The National Electrical Code Correlating Committee has recognized these responsibilities and has issued this manual. Preparation and Date of Adoption. This manual was originally prepared by the Editorial Task Group of the National Electrical Code Committee and adopted by the National Electrical Code Correlating Committee on May 13, 1969. It was amended September 22, 1975, October 11, 1984, October 12, 1989, and May 9, 1994. In January 1999, the Correlating Committee Task Group on the Usability of the NEC rewrote the manual. It was adopted by the National Electrical Code Correlating Committee on March 19, 1999 and by the Standards Council on April 15, 1999. It was amended March 1, 2001, January 15, 2003, and August 9, 2011, August 2015, and December 2020. 2 TABLE OF CONTENTS Foreword ........................................................................................................ 2 Chapter 1 General 4 1.1 Purpose ............................................................................................
    [Show full text]
  • 90 INTRODUCTION to the National Electrical Code
    ARTICLE INTRODUCTION TO THE 90 NATIONAL ELECTRICAL CODE Introduction to Article 90—Introduction to the National Electrical Code Many NEC violations and misunderstandings wouldn’t occur if people doing the work simply understood Article 90. For exam- ple, many people see Code requirements as performance standards. In fact, the NEC requirements are bare minimums for safety. This is exactly the stance electrical inspectors, insurance companies, and courts take when making a decision regard- ing electrical design or installation. Article 90 opens by saying the NEC isn’t intended as a design specification or instruction manual. The National Electrical Code has one purpose only, and that’s the “practical safeguarding of persons and property from hazards arising from the use of electricity.” The necessity of carefully studying the NEC rules can’t be overemphasized, and the role of textbooks such as this one is to help in that undertaking. Understanding where to find the rules in theCode that apply to the installation is invaluable. Rules in several different articles often apply to even a simple installation. Article 90 then describes the scope and arrangement of the NEC. The balance of this article provides the reader with informa- tion essential to understanding the Code rules. Typically, electrical work requires you to understand the first four chapters of theNEC which apply generally, plus have a working knowledge of the Chapter 9 tables. That understanding begins with Article 90. Chapters 5, 6, and 7 make up a large portion of the Code, but they apply to special occupancies, special equipment, or other special conditions.
    [Show full text]
  • ISO Update Supplement to Isofocus
    ISO Update Supplement to ISOfocus October 2019 International Standards in process ISO/CD Agricultural and forestry tractors — Roll-over 12003-2 protective structures on narrow-track wheeled An International Standard is the result of an agreement between tractors — Part 2: Rear-mounted ROPS the member bodies of ISO. A first important step towards an Interna- TC 28 Petroleum and related products, fuels tional Standard takes the form of a committee draft (CD) - this is cir- and lubricants from natural or synthetic culated for study within an ISO technical committee. When consensus sources has been reached within the technical committee, the document is sent to the Central Secretariat for processing as a draft International ISO/CD 11009 Petroleum products and lubricants — Deter- Standard (DIS). The DIS requires approval by at least 75 % of the mination of water washout characteristics of member bodies casting a vote. A confirmation vote is subsequently lubricating greases carried out on a final draft International Standard (FDIS), the approval ISO/CD 13736 Determination of flash point — Abel closed-cup criteria remaining the same. method ISO/CD TR Petroleum products and other liquids — Guid- 29662 ance for flash point testing ISO/CD Lubricants, industrial oils and related prod- 12925-2 ucts (class L) — Family C (Gears) — Part 2: Specifications of categories CKH, CKJ and CKM (lubricants open and semi-enclosed gear systems) CD registered TC 29 Small tools ISO/CD 525 Bonded abrasive products — General requirements Period from 01 September to 01 October 2019 ISO/CD 5743 Pliers and nippers — General technical These documents are currently under consideration in the technical requirements committee.
    [Show full text]
  • Industrial MI Wiring Cable
    Industrial MI Wiring Cable Installation Manual for Alloy 825 Sheath Cable Wiring Systems Important Safeguards and Warnings WARNING: FIRE AND SHOCK HAZARD. nVent PYROTENAX mineral insulated (MI) industrial wiring cables must be installed in accordance with the requirements of national and local codes and standards, the installation instructions in this manual, and the customer’s specification. Read these important safeguards and carefully follow the installation instructions. • Ensure the cable has been stored properly and is in good condition prior to commencing installation. • Always use safe working practices when installing cables, observing OSHA and other national safety rules. • Store cables indoors in a clean, dry, covered area, if possible. • During the time that the cables are exposed and during cable pulling activities, protect cables from nearby or overhead work to prevent damage to the cable sheath. • Do not pull cables around corners that have sharp edges, such as corners in cable trays, or other obstructions. • Prevent damage to cables by removing any abrasions or sharp edges from surface of support system. • Damage to cables or components can cause sustained electrical arcing or fire. Do not energize cables that have been damaged. Damaged cable or terminations may need to be repaired or replaced. Damaged cable should be repaired by a qualified person. • When installing cables which may be exposed to hydrocarbon flash fires, use only steel or stainless steel in the support system. ii | nVent.com Table of Contents General Information
    [Show full text]
  • 2011 National Electrical Code Amendments
    541 DeKalb Avenue Sycamore, IL 60178 Building (815) 895-4434 Building & Engineering Department Engineering (815) 895-4557 Fax (815) 895-7572 2011 NATIONAL ELECTRICAL CODE AMENDMENTS The 2011 National Electrical Code (NEC), adopted in Section 9-4-1, Subsection A of the Sycamore City Code as the electrical code of the City, is amended and revised in the following respects: 1. Service Equipment – Disconnecting Means: Means shall be provided to disconnect all conductors in a building from the service entrance conductors. The service disconnecting means shall be installed at a readily accessible location either outside the building or inside the building nearest the point of entrance of the service conductors. The maximum distance from the point of entrance of service conductors to a readily accessible service disconnecting means shall be six (6) feet. 2. All residential, commercial and industrial electrical services shall be installed with rigid metal conduit (RMC) or intermediate metal conduit (IMC). PVC and service entrance cable is not allowed. Electrical metallic tubing (EMT) is permitted between the meter enclosure and the electrical panel only if compression fittings are used and provided the EMT exits the back of the meter enclosure and is not exposed to weather. 3. When additional grounding is required for hot tubs, spas or similar equipment, the grounding conductor is allowed to be located at the cold water pipe of that piece of equipment provided the ground clamp is accessible. If the ground clamp is not accessible, a minimum #8 insulated copper conductor shall be run from the motor or pump back to the electrical panel.
    [Show full text]
  • Electrical Safety in the Workplace® ARTICLE 90 Introduction
    ARTICLE 90 — INTRODUCTION 90.2 NOTE: The following draft shows how the draft of the proposed 2012 edition of NFPA 70E looks based on NFPA ARTICLE 90 staff’s reading of the Committee Actions contained in the Introduction NFPA 70E Technical Committee Report of the Technical Committees on Electrical Safety in the Workplace (i.e., the Committee Actions in the Report on Proposals). NFPA Staff 90.1 Purpose. The purpose of this standard is to provide a frequently prepare and make available drafts such as this as practical safe working area for employees relative to the an aid to participants in reviewing Technical Committee hazards arising from the use of electricity. Reports. Participants are encouraged to review this Report on Proposals and to raise any issues they believe need reso- 90.2 Scope. lution through the making of appropriate comments. Please (A) Covered. This standard addresses electrical safety re- submit your public comments on the proposals, not on the quirements for employee workplaces that are necessary for draft. As mentioned previously, the draft is only an aid for the practical safeguarding of employees during activities reviewing the document, incorporating the proposals. such as the installation, inspection, operation, maintenance, For further information on NFPA codes and standards and demolition of electric conductors, electric equipment, development rules or on how to participate in the NFPA signaling and communications conductors and equipment, codes and standards development process, check the NFPA and raceways for
    [Show full text]
  • News Iso Standards: 2013/12
    NEWS ISO STANDARDS: 2013/12 ISO/IEC 2382-4: 1999 150.80 € ISO/IEC 2382-4 Information technology -- Vocabulary -- Part 4: Buy Organization of data ISO/IEC 17000: 2004 200.20 € ISO/IEC 17000 Conformity assessment -- Vocabulary and general Buy principles ISO 3167: 2002 85.80 € ISO 3167 Plastics -- Multipurpose test specimens Buy ISO/IEC 23008-2: 2013 309.40 € ISO/IEC 23008-2 Information technology -- High efficiency coding and Buy media delivery in heterogeneous environments -- Part 2: High efficiency video coding ISO 3297: 2007 127.40 € ISO 3297 Information and documentation -- International standard Buy serial number (ISSN) ISO 9912-2: 2013 85.80 € ISO 9912-2 Agricultural irrigation equipment -- Filters for microirrigation Buy -- Part 2: Strainer-type filters and disc filters ISO 9912-3: 2013 75.40 € ISO 9912-3 Agricultural irrigation equipment -- Filters for microirrigation Buy -- Part 3: Automatic flushing strainer-type filters and disc filters ISO 10957: 2009 104.00 € ISO 10957 Information and documentation -- International standard Buy music number (ISMN) ISO 17992: 2013 119.60 € ISO 17992 Iron ores -- Determination of arsenic content -- Hydride Buy generation atomic absorption spectrometric method ISO 11783-14: 2013 223.60 € ISO 11783-14 Tractors and machinery for agriculture and forestry -- Buy Serial control and communications data network -- Part 14: Sequence control ISO 27729: 2012 111.80 € ISO 27729 Information and documentation -- International standard Buy name identifier (ISNI) ISO 27730: 2012 85.80 € ISO 27730 Information
    [Show full text]
  • International Electrical Standards & Regulations
    International electrical standards & regulations AN OVERVIEW OF ELECTRICAL INSTALLATIONS Introduction to the installations world he world of electrical installations knowledge of the wiring suited to your specific Tis not always straightforward. regulations and standards requirements in terms of Working on an international project which are applicable in electrical installations and electrical engineers are often bewildered the specific country. communication networks. by the extensive amount of electrical This document compares Continuous innovation standards and wiring regulations which the basic framework No less than 1 800 determines their decisions. of the standards. people are dedicated Therefore, it is essential full-time to research and Rely on the world’s Detailed knowledge for the design engineer development. On average, leading specialist of the wiring rules to obtain more detailed Legrand invests 5% of its As one of the world The purpose of this information by contacting sales each year in R&D. leading specialists document is to clearly the appropriate standards in wiring accessories, present the most and building regulations Sustainable Legrand actively participate frequently encountered organisations. Development: a priority to the elaboration of the sets of wiring rules, For many years, installation standards showing the main One of the most complete the Legrand Group at international (IEC), technical characteristics offer of the market has drawn strength regional (NEC) and local of each set of installation 130 000 catalogue items! from its values to ensure levels. Thus, the technical and main accessories For you, the wealth profitable, sustainable expertise of the Legrand standards. Obviously, on of the Legrand Group’s and responsible growth people makes it possible any given project, it is catalogue offer is the in its business.
    [Show full text]
  • Supply Circuit Disconnecting Means with Rotary Handles in Compliance with NFPA 79 and UL 508A
    www.eaton.com www.moeller.net Supply circuit disconnecting means with rotary handles in compliance with NFPA 79 and UL 508A Technical Paper Dipl.-Ing. Wolfgang Esser Supply circuit disconnecting means with rotary handles in compliance with NFPA 79 and UL 508A – Fulfilling key requirements of relevant North American standards – Abstract Introduction machinery, particularly those involving IEC style door mounted rotary handles, Differences between IEC and North In the IEC world the rotary handle is the its primary goal naturally is not to make American standards already become popular choice, and it’s by far the most component design more difficult, but apparent when discussing even the most widely encountered type of operating rather to provide industry floor person- basic of component accessories, such as handle for main disconnect switches in nel with an extra measure of protection the operating handle of a supply circuit these various countries. In the US and from electric shock through the use of disconnecting switch. For example, main Canada, the situation is markedly differ- suitable enclosures, specifically the disconnect switches equipped with door ent, and the use of similar rotary handles need for adequate interlocking provi- mounted rotary handles, and installed in for main disconnect switch applications sions with the supply disconnecting industrial control panels for industrial is not nearly as prevalent, chiefly due to means whenever there is the potential machinery applications, essentially the fact that the conventionally door for exposure to live equipment. require the use of an additional internally mounted operating handle separates The new supplementary handles Type mounted supplemetary handle in order to from the switch when the door is NZM…-XHB-DA(R)-NA from Eaton meet all of the requirements found in the opened, and this feature is considered Moeller fulfill all of the more stringent relevant North American standards deal- less than desirable.
    [Show full text]
  • Nummernverzeichnis Der Behandelten Normen
    Nummernverzeichnis der behandelten Normen DIN Seite DIN Seite DIN Seite DIN 6-1 83 DIN 244 250 DIN 669 497 DIN 6-2 83 DIN 254* 94 DIN 670 497 DIN 13 252 DIN 267-2 339,340 DIN 671 497 DIN 13-1* 253 DIN 267-6 340 DIN 705 188 DIN 13-2* 253 DIN 267-10 340 DIN 720 189 DIN 13-3* 253 DIN 267-13 340 DIN 747 169 DIN 13-4* 253 DIN 267-24 340 DIN 748 170 DIN 13-5* 253 DIN 316 370 DIN 748-3 853 DIN 13-6* 254 DIN 319 237 DIN 780-1 209 DIN 13-7* 255 DIN 322 205 DIN 780-2 209 DIN 13-8* 255 DIN 323-1 20 DIN 781 272 DIN 13-9* 255 DIN 323-2 20 DIN 803 273 DIN 13-10* 255 DIN 332 148 DIN 804 274 DIN 13-11* 255 DIN 336 266 DIN 820-1 14,17 DIN 34* 82 DIN 405-1* 266 DIN 820-2 18,19 DIN 39 236 DIN 406-10 89 DIN 820-4 17 DIN 66 357 DIN 406-11 89 DIN 820-12 1025 DIN 74-1* 358 DIN 406-12 89 DIN 824 82 DIN 76-1 143 DIN 432 394 DIN 835 367 DIN 78 145 DIN 442 241 DIN 876 208 DIN 79 164 DIN 443 241 DIN 908 372 DIN 82 148 DIN 444 371 DIN 909 372 DIN 93 393 DIN 461 136 DIN 910 372 DIN 95 377 DIN 463 394 DIN 913 368 DIN 96 377 DIN 470 241 DIN 914 368 DIN 97 377 DIN 471 395 DIN 915 368 DIN 98* 236 DIN 472 395 DIN 916 368 DIN 99* 238 DIN 475 164 DIN 935 387 DIN 102 336 DIN 475-1 164 DIN 935-1* 387 DIN 103-1 263 DIN 475-2 164 DIN 938-2* 367 DIN 103-2 263 DIN 476-1 78 DIN 950* 234 DIN 103-3 263 DIN 476-2 78 DIN 974-1 359 DIN 103-4 263 DIN 502 206 DIN 974-2 359 DIN 109-1 173 DIN 504 206 DIN 979 387 DIN 109-2 173 DIN 505 206 DIN 988 207 DIN 111 173 DIN 509 149 DIN 1013-1 489 DIN 115-1 176 DIN 513-1 265 DIN 1013-2 489 DIN 115-2 176 DIN 513-2 265 DIN 1014-1 489 DIN 116 174 DIN
    [Show full text]
  • IS 12640-1 (2008): Residual Current Operated
    इंटरनेट मानक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public. “जान का अधकार, जी का अधकार” “परा को छोड न 5 तरफ” Mazdoor Kisan Shakti Sangathan Jawaharlal Nehru “The Right to Information, The Right to Live” “Step Out From the Old to the New” IS 12640-1 (2008): Residual Current Operated Circuit - Breakers for Household and Similar Uses, Part 1: Circuit-Breakers Without Integral Overcurrent Protection (RCCBs) [ETD 7: Low Voltage Switchgear and Controlgear] “ान $ एक न भारत का नमण” Satyanarayan Gangaram Pitroda “Invent a New India Using Knowledge” “ान एक ऐसा खजाना > जो कभी चराया नह जा सकताह ै”ै Bhartṛhari—Nītiśatakam “Knowledge is such a treasure which cannot be stolen” IS 12640 (Part 1) :2008 IEC 61008-1:1996 Indian Standard RESIDUAL CURRENT OPERATED CIRCUIT- BREAKERS FOR HOUSEHOLD AND SIMILAR USES PART 1 CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION (RCCBS) (First Revision ) ICS 29.120.50 @ 61S 2008 BUREAU OF INDIAN STANDARDS MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG NEW DELHI 110002 Apti 2008 Price Rs.
    [Show full text]
  • Electrician's Exam Preparation Guide to the 2017
    Buy this title complete here: http://bit.ly/2yP4hOJ $67.99 ELECTRICIAN’S EXAM PREPARATION GUIDE Tenth Edition Based on the 2017 NEC® by John E. Traister Revised and Updated by Rob Adair IncludesOnline inside the backPreview cover: Inside the back cover of this book you’ll find a software download certificate. To access the download, follow the instructions printed there. Contains all the questions in the book in interactive self-test software that makes studying almost fun. Each answer is explained, and shows the pertinent NEC® section at the click of the mouse. Use the study mode to get an immediate response on each answer. Use the exam mode for a timed exam — just like the real one, and see your grade when finished. ® Craftsman Book Company 6058 Corte del Cedro, Carlsbad, CA 92011 Buy similar Craftsman Book Co. titles here: https://www.Craftsman-Book.com Buy this title complete here: http://bit.ly/2yP4hOJ Acknowledgments We are indebted to several individuals and organizations who helped in the preparation of this book. One group is the electrical examining boards throughout the United States. A list of these organiza- tions appears in Appendix I of this book. The following were especially helpful in furnishing refer- ence materials or else helping with the production. National Fire Protection Association® (NFPA®) C. Keeler Chapman, Artwork John D. Lee, Sr., Question Verification & Code Consultant Portions of this publication are reprinted with permission from NFPA 70®-2017 National Electrical Code®, Copyright® 2016 National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject, which is represented only by the standard in its entirety.
    [Show full text]