Page 1 CHAPTER 21. ELECTRICAL CODE ARTICLE I. THE CHAPTER 21. ELECTRICAL CODE ARTICLE I. THE ELECTRICAL CODE Sec. 21.0010 Short Title. This Chapter will be known and may be cited as “The Electrical Code.” Sec. 21.0030 National Electrical Code Adopted. Certain documents, copies of which are filed in the office of the Building Commissioner, said copies being marked and designated as the 2008 National Electrical Code, as published by the National Fire Protection Association are hereby adopted along with its annexes as the Electrical Code of the City of Webster Groves, Missouri, for the control of buildings and structures as herein provided; and each and all terms of the 2008 National Electrical Code are hereby referred to, adopted and made a part hereof as if fully set out in this ordinance with the additions, insertions, deletions and changes prescribed in this Ordinance. Sec. 21.0040 Jurisdictional Titles. Throughout the 2009 International Code Council Electrical Code – Annex H, Administration and Enforcement, whenever the terms “Name of Jurisdiction” or “Local Jurisdiction” appear, it shall be deemed to mean “Webster Groves, Missouri.” Likewise whenever the “Code Official” appears it shall be deemed to mean the “Building Commissioner.” Sec. 21.0050 Jurisdictional Titles. Throughout the 2008 National Electrical Code, whenever the terms “Name of Jurisdiction” or “Local Jurisdiction” appear, it shall be deemed to mean “Webster Groves, Missouri.” Likewise whenever the “Code Official” appears it shall be deemed to mean the “Building Commissioner.” Sec 21.0200 Amendments to National Electric Code Chapter 2 – Wiring and Protection 210.12 Arc-Fault Circuit Interrupter Protection. (A) Definition. An arc-fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de- energize the circuit when an arc fault is detected. (B) Dwelling Unit Bedrooms. All branch circuits that supply 125-volt, single-phase, 15- and 20- ampere outlets installed in dwelling unit bedrooms shall be protected by an arc-fault circuit interrupter listed to provide protection of the entire branch circuit. Exception: Smoke detectors, overhead lighting circuits, and dedicated outlets located in bedrooms. Sec. 21.0400 Amendments to National Electrical Code Chapter 4 – Equipment for General Use 406.11 Tamper-Resistant Receptacles in Dwelling Units. In all areas specified in 210.52, 125-volt, 15- and 20-ampere receptacles shall be listed tamper-resistant receptacles. Exception: Receptacles in the following locations shall not be required to be tamper-resistant: (1) Receptacles located more than five and one half (5½) feet above the floor. (2) Receptacles that are part of a luminaire or appliance, Page 1 THE CODE OF WEBSTER GROVES - 2018 Electrical Code Chapter 21 (3) A single receptacle or a duplex receptacle for two appliances located within dedicated space for each appliance that, in normal use, is not easily moved from one place to another and that is cord-and-plug connected in accordance with 400.7(A)(6), (A)(7), or (A)(8), (4) Nongrounding receptacles used for replacements as permitted in 406.3(D)(2)(a). Sec. 21.1000 Amendments to National Electrical Code Annex A – Product Safety Standards ANNEX A – Product Safety Standards is adopted without amendment. This annex is not a part of the requirements of this NFPA document but is included for informational purposes only. Sec. 21.1100 Amendments to National Electrical Code Annex B – Application Information for Ampacity Calculations ANNEX B – Application Information for Ampacity Calculations is adopted without amendment. This annex is not a part of the requirements of this NFPA document but is included for informational purposes only. Sec. 21.1200 Amendments to National Electrical Code Annex C – Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size ANNEX C – Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size is adopted without amendment. This annex is not a part of the requirements of this NFPA document but is included for informational purposes only. Sec. 21.1300 Amendments to National Electrical Code Annex D – Examples ANNEX D – Examples is adopted without amendment. This annex is not a part of the requirements of this NFPA document but is included for informational purposes only. Sec. 21.1400 Amendments to National Electrical Code Annex E – Types of Construction ANNEX E – Types of Construction is deleted in its entirety and amended by inserting the following: Types of Construction are those identified in the 2009 edition of the International Code Council’s International Building Code. Sec. 21.1500 Amendments to National Electrical Code Annex F – Availability and Reliability for Critical Operations Power Systems; and Development and Implementation of Functional Performance Tests (FPT’s) for Critical Operations Power Systems Annex F – Availability and Reliability for Critical Operations Power Systems; and Development and Implementation of Functional Performance Tests (FPT’s) for Critical Operations Power Systems is adopted without amendment. This annex is not a part of the requirements of this NFPA document but is included for informational purposes only. Sec. 21.1600 Amendments to National Electrical Code Annex G – Supervisory Control and Data Acquisition (SCADA) Page 2 THE CODE OF WEBSTER GROVES - 2018 Electrical Code Chapter 21 Annex G – Supervisory Control and Data Acquisition (SCADA) is adopted without amendment. This annex is not a part of the requirements of this NFPA document but is included for informational purposes only. Sec. 21.1700 Amendments to National Electrical Code Annex H – Administration and Enforcement ANNEX H – Administration and Enforcement is deleted in its entirety and amended by inserting the following: Annex H Article 1 SCOPE SECTION 101 GENERAL 101.1 Title. These regulations shall be known as the electrical Code – Administrative Provisions of the City of Webster Groves, Missouri and shall be cited as such and will be referred to herein as “this code.” 101.2 Purpose. The purpose of this code is to provide minimum standards to safeguard life or limb, health, property and public welfare by regulating and controlling the design, construction, installation, quality of materials, location, operation, and maintenance or use of electrical systems and equipment. 101.3 Scope. This code shall regulate the design, construction, installation, alteration, repairs, relocation, replacement, addition to, use or maintenance of electrical systems and equipment. SECTION 102 APPLICABILITY 102.1 General. The provisions of this code shall apply to all matters affecting or relating to structures and premises, as set forth in 101. 102.1.1 Existing installations. Except as otherwise provided for in this article, a provision in this code shall not require the removal, alteration or abandonment of, nor prevent the continued utilization and maintenance of, existing electrical systems and equipment lawfully in existence at the time of the adoption of this code. 102.1.2 Maintenance. Electrical systems, equipment, materials and appurtenances, both existing and new, and parts thereof shall be maintained in proper operating condition in accordance with the original design and in a safe, hazard-free condition. Devices or safeguards that are required by this code shall be maintained in compliance with the code edition under which installed. The owner or the owner’s designated agent shall be responsible for the maintenance of the electrical systems and equipment. To determine compliance with this provision, the code official shall have the authority to require that the electrical systems and equipment be reinspected. Page 3 THE CODE OF WEBSTER GROVES - 2018 Electrical Code Chapter 21 [EB] 102.1.3 additions, alterations and repairs. Additions, alterations, renovations and repairs to electrical systems shall comply with the provisions of the International Existing Building Code and this code, as applicable. [EB] 102.1.4 Change in occupancy. The provisions if the International Existing Building Code shall apply to all buildings undergoing a change of occupancy. 102.1.5 Moved buildings. Electrical systems and equipment that are a part of buildings or structures moved into or within the jurisdiction shall comply with the provisions of this code for new installations. 102.2 Differences. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. 102.3 Other laws. The provisions of this code shall not be deemed to nullify any provisions of local, state or federal law. 102.4 Validity. In the event any part of provision of this code is held to be illegal or void, this shall not have the effect of making void or illegal any of the other parts or provisions thereof, which are determined to be legal; and it shall be presumed that this code would have been adopted without such illegal or invalid parts or provisions. 102.4.1 Segregation of invalid provisions. Any invalid part of this code shall be segregated from the remainder of this code by the court holding such part invalid, and the remainder shall remain effective. 102.5 Application of references. References to article or section numbers, or to provisions not specifically identified by number, shall be construed to refer to such articles, sections or provisions of this code. 102.6 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Annex A and such codes and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between provisions of this code and referenced codes or standards, the provisions of this code shall apply. Exception. Where enforcement of a code provision would violate the conditions of the listing of the equipment or appliance, the conditions of the listing and manufacturer’s instructions shall apply.
Recommended publications
  • “Complying with All Laws” During Design and Construction by Eric Pempus, AIA
    Submitted August 9, 2016 “Complying with all laws” during design and construction By Eric Pempus, AIA Consider this situation: You have been awarded a commission to design a building for a new client. You propose using the AIA’s Standard Form of Agreement B101 as your owner-architect contract, but the client insists you sign a version of the B101 “with just a few minor changes.” You notice that one of those changes requires you to “comply with all laws, rules, and regulations," rather than, as the B101 states, to “review laws, codes, and regulations applicable to the Architect’s services.” That changed language should be setting off alarm bells for you. One of the most overlooked yet dangerous pitfalls for an architect is a provision in a legal document requiring a design professional to “comply with all laws, rules, and regulations" or similar language. However, such a provision can create a trap for an unsuspecting architect. The problems with “complying with all codes” A large number of laws apply to the design and construction of buildings. These laws govern: life safety (national model building codes as well as local variations) fire protection accessibility (ADA as well as local requirements) zoning occupant safety (e.g., OSHA) sustainable design wetlands preservation public health historic preservation and employment (federal, state, and local). It may in fact be impossible to comply with all laws that apply to a particular project because those laws may have contradictory provisions. To illustrate this point, the Advisory
    [Show full text]
  • Why Homeowners Should Not Obtain the Building Permit for Construction Projects
    MASSACHUSETTS FEDERATION OF BUILDING OFFICIALS, Inc. .. .. ,~> . A.:t' ··.·• President - Dan Walsh Past Presidents Vice President - Curtis Meskus David Moore, Steve Frederickson Treasure - David Jensen Paul Tacy, Robert Camacho Secretary - Michael Mendoza Why homeowners should not obtain the building permit for construction projects. Massachusetts homeowners are allowed to obtain their own building permit for renovations and improvements to their homes. Obtaining your own building permit comes with significant responsibility and risk. Professionals recommend that only homeowners with significant experience and skill renovating homes and up to date knowledge of building codes pull their own permits. Before you decide to apply for your own building permit be sure you know what will be required to comply with the new Massachusetts building code and all related state and local requirements. Not knowing can cause significant project delays and inconvenience and potentially cost you thousands of dollars to rectify mistakes. For example, if work on a project is halfway done and it is not compliant with structural or energy code you may have to remove the work and replace it to meet the new code. The Risks of Homeowner - Obtained Permits Excluded from the Guaranty Fund: When the homeowner obtains a building permit they are not eligible to access the Guaranty Fund established by the Home Improvement Law, M.G.L. c142A. This fund was created to protect homeowners from losses incurred as a result of contractor or sub-contractor work performed in a poor or un-workmanlike manner, or work that is in violation of common law or code. For example if a homeowner obtains the building permit and hires a contractor who abandons the job because he priced it too low, the money lost cannot be recovered from the Guaranty Fund.
    [Show full text]
  • ELECTRICAL CODE* ______*Editor’S Note: Ordinance No
    ARLINGTON COUNTY CODE Chapter 7 ELECTRICAL CODE* __________ *Editor’s note: Ordinance No. 09-11, adopted April 28, 2009, amended Chapter 7, in its entirety, to read as herein set out. __________ § 7-1. Title and Scope. § 7-2. Definitions. § 7-3. Availability of Codes. § 7-4. Administration and Enforcement. § 7-5. Reserved. § 7-6. Permits and Fees. § 7-7. General Provisions. § 7-1. Title and Scope. A. Title. This chapter shall be known as the "Arlington County Electrical Code" and may be so cited. B. Scope--New electrical systems. This Code shall apply to electrical systems and to parts thereto which are hereafter installed in buildings of the occupancy classifications enumerated in the Virginia Uniform Statewide Building Code. (Ord. No. 89-25, 9-23-89); Ord. No. 07-13, 9-18-07, effective 10-1-07; Ord. No. 08-08, 4-19-08, effective 7-1-08; Ord. No. 09-11, 4-28-09) § 7-2. Definitions. The following words and terms, when used in this chapter, shall have the following meanings unless the context clearly indicates otherwise: “Building Official” means the Inspection Services Division Chief of Arlington County or his designee. “Construction Code Inspector” means a qualified person charged with the inspections of all electrical systems and electrical work performed in the County. (Ord. No. 89-25, 9-23-89; Ord. No. 95-14, 8-8-95; Ord. No. 97-7, 4-12-97; Ord. No. 07-13, 9-18-07, effective 10-1- 07; Ord. No. 08-08, 4-19-08, effective 7-1-08; Ord. No.
    [Show full text]
  • 2020 National Electrical Code® Style Manual
    2020 NATIONAL ELECTRICAL CODE® STYLE MANUAL 1 FOREWORD August 2020 The National Electrical Code® is used nationally and internationally as the basis for safeguarding persons, buildings, and their contents from hazards arising from the use of electricity. It is vitally important that the text be as explicit as possible, and that maximum consistency be achieved in the language used in the text. The Code contains those provisions considered necessary for safety and thus is widely used as a basis for legal enforcement in the installation of electrical conductors and equipment in buildings and certain other premises (as detailed in the Code itself); this places a major responsibility on those involved in the preparation of document text to use forms of expression that promote uniform interpretation. The National Electrical Code Correlating Committee has recognized these responsibilities and has issued this manual. Preparation and Date of Adoption. This manual was originally prepared by the Editorial Task Group of the National Electrical Code Committee and adopted by the National Electrical Code Correlating Committee on May 13, 1969. It was amended September 22, 1975, October 11, 1984, October 12, 1989, and May 9, 1994. In January 1999, the Correlating Committee Task Group on the Usability of the NEC rewrote the manual. It was adopted by the National Electrical Code Correlating Committee on March 19, 1999 and by the Standards Council on April 15, 1999. It was amended March 1, 2001, January 15, 2003, and August 9, 2011, August 2015, and December 2020. 2 TABLE OF CONTENTS Foreword ........................................................................................................ 2 Chapter 1 General 4 1.1 Purpose ............................................................................................
    [Show full text]
  • Electrical Inspection Checklist for One-Family Homes Based on the 2020 National Electrical Code® (NEC®)
    Electrical Inspection Checklist for One-Family Homes Based on the 2020 National Electrical Code® (NEC®) NOTE: The Board of Electricity adopted the 2020 National Electrical Code (NEC) with an effective date of Nov. 17, 2020. Accordingly, the Department of Labor and Industry began enforcing the 2020 NEC on Nov.17, 2020. Electrical work authorized by permits issued on or after this date must comply with the 2020 NEC. Electrical license examinations are based on the requirements of the 2020 NEC beginning Jan. 1, 2021. However, due to concerns regarding the availability of 2-pole GFCI circuit breakers, the department delayed enforcement of the requirements for 250-volt GFCI receptacles and outlet requirements found in NEC 210.8(A) and 210.8(F). On April 5, 2021, DLI will begin enforcing the 250-volt GFCI receptacle and outlet requirements found in NEC 210.8(A) and 210.8(F). Industry circuit breaker manufacturers have confirmed that supply-chain challenges will be resolved in March 2021. Electrical work authorized by permits issued on or after April 5, 2021, must comply with the 2020 NEC. 001 An owner (i.e. homeowner) who files a Request for Electrical Inspection form (i.e. permit) with the Department of Labor and Industry or other electrical inspection authority is signing an affidavit and declaring they own and occupy the residence and they will personally perform all of the electrical work, including the planning and laying out of the electrical work. 002 The term “owner” is defined in law as a natural person who physically performs electrical work on premises the person owns and actually occupies as a residence or owns and will occupy as a residence upon completion of construction.
    [Show full text]
  • 20171 Minimum Design and Construction Requirements
    Virginia Housing Development Authority 20171 Minimum Design and Construction Requirements Requirements for All Developments The following requirements were created to address issues related to the design, construction, maintenance, marketing, life cycle costs and aesthetic concerns for developments utilizing low income housing tax credits (LIHTC), and/or developments financed by the Virginia Housing Development Authority (VHDA). Submission requirements for VHDA loan applications are listed on the Architectural & Engineering Review sheet which can be found at the conclusion of the Minimum Design and Construction Requirements (MDCR). Submission requirements for the LIHTC program are contained in the tax credit application. Drawings, specifications and scope of work are to comply with the latest applicable issue of the Virginia Uniform Statewide Building Code (USBC)2, International Building Code (IBC)3, other applicable Virginia and national codes, requirements of localities, prevailing design and construction practices and the Minimum Design and Construction Requirements of VHDA. Installation of materials, equipment, products, and building systems are to be per the manufacturers’ requirements, specifications, and recommendations. All developments are to comply with accessibility requirements of USBC. Requirements for New Construction SITE WORK 1. Finished floor elevations of buildings are to be a minimum of 8 inches higher than the adjoining finished grade. When achieving an 8 inch height separation is not feasible, due to accessibility requirements or other conditions, provide an alternate solution acceptable to VHDA. 2. Areas around buildings are to be graded to have a minimum 5% slope away from foundation walls for a minimum distance of 10 feet, per IBC. Install yard drains, storm inlets, or drainage pipes under concrete walks to drain properly if the space between foundation walls and concrete walks is less than 10 feet.
    [Show full text]
  • Building Codes and Housing
    Building Codes and Housing Building Codes and Housing David Listokin Rutgers University David B. Hattis Building Technology Inc. Abstract This article examines whether and to what extent building codes affect housing costs. It first describes these technical provisions, then considers how building codes could theoretically affect housing costs, and finally analyzes empirical studies on the subject. While the latter are dated and suffer from other limitations, the more rigorous quan­ titative analyses indicate that codes increase housing costs by 5 percent or less. Further, building codes are in a state of flux and we need to examine how the current generation of regulations affects housing. Thus, building codes merit contemporary investigation; however, these regulations have much less impact on housing costs compared to other regulations such as zoning and subdivisions requirements. Introduction and Summary This article considers the regulation of housing construction (single-family and multifamily, new construction and rehabilitation of existing buildings), focusing on the building code (a broad term specifically defined in this article). It first describes the building code and then traces its history. The history of the building code is important because numerous events and disparate parties have shaped the code, which currently is in a state of evolution. The code is moving toward two national model templates that influence local building code regulations, and away from the three regional-oriented model codes that have been influencing local regulations. In theory, the building code could adversely affect housing production and could increase housing costs through both substantive (technical) and administrative impediments. Examples of the former include restrictions of cost-saving materials and technologies and barriers to mass production; the latter encompasses such barriers as administrative conflicts among different administering parties (for example, building and fire departments) and inadequately trained inspectors.
    [Show full text]
  • Building Code Compliance: Managing the Risks
    Fall 2016 Building code compliance: managing the risks To many architects and engineers (A/E’s), the words Gail S. Kelley, P.E., J.D. ConstructionRisk, LLC “building code” have a distinctly negative connotation. This is not entirely surprising— the words often come up in the context of an obscure requirement that no one understands. Or even worse, two obscure requirements that appear to contradict each other. Being able to design to the applicable building code is a non-negotiable In agreeing to comply with applicable codes, Rather than developing an entire building element of an A/E’s work. however, the A/E should be careful to code, states generally base their codes on a Even if a contract does not understand exactly what they are agreeing to. model code developed by a standards require compliance with In addition, if there are aspects of the design organization. For most of the 20th century, that the A/E is not familiar with, or the there were three commonly-used model applicable codes, courts will project is in a jurisdiction in which the A/E codes in the U.S.: the Uniform Building Code generally find that failure to does not typically work, the A/E might want (UBC), the Building Officials Code comply with the building to consider using a code consultant. Administrators National Building Code (BOCA/NBC) and the Standard Building Code code is negligence. Model codes (SBC). The UBC was primarily used in the Building codes and standards are the midwestern and western states, the BOCA/ rules and guidelines that specify the minimum NBC was used in the northeastern states and acceptable level of safety for buildings and the SBC was used in the South.
    [Show full text]
  • General Q. How Can I File a Building Code Or Zoning Complaint?
    Inspectors Schedule Q. What are the inspectors’ office hours? A. The Building Inspector’s hours are 8:00-10:00am and 12:00-2:00pm M thru F. The Wiring Inspector’s hours are 8:00-9:00am and 2:30-4:00pm M thru F. The Plumbing and Gas Inspector’s hours are 8:00-9:00am and 3:00-4:00pm M thru F. Q. What are the inspection times? A. The building inspections are conducted from 10:00am-12:00pm and 2:00-3:30pm M thru F. The wiring inspections are conducted from 9:00am-2:30pm M thru F. General Q. How can I file a Building Code or Zoning Complaint? A. In order to file a complaint, click on the Request for Enforcement Link. Form must be filled out completely. Permits Information Q. Does a contractor need to register with Town of Wellesley before he/she can apply for a permit? A. All Contractors and Designees need to register with the Town before they can do work in the town. They must come to the Town Hall Building Department with the licenses they are registering. No photo copies will be excepted and contractor must appear in person. Q. When is a building, gas, plumbing, or electrical permit required? A. All work that is regulated by the Mass State Building Code 780 CMR 110.0 requires a permit. With very few exceptions, a permit is required for most building, gas, plumbing, or electrical work. Please error on the side of caution and contact the Building Department to verify if work to be performed requires a permit.
    [Show full text]
  • 90 INTRODUCTION to the National Electrical Code
    ARTICLE INTRODUCTION TO THE 90 NATIONAL ELECTRICAL CODE Introduction to Article 90—Introduction to the National Electrical Code Many NEC violations and misunderstandings wouldn’t occur if people doing the work simply understood Article 90. For exam- ple, many people see Code requirements as performance standards. In fact, the NEC requirements are bare minimums for safety. This is exactly the stance electrical inspectors, insurance companies, and courts take when making a decision regard- ing electrical design or installation. Article 90 opens by saying the NEC isn’t intended as a design specification or instruction manual. The National Electrical Code has one purpose only, and that’s the “practical safeguarding of persons and property from hazards arising from the use of electricity.” The necessity of carefully studying the NEC rules can’t be overemphasized, and the role of textbooks such as this one is to help in that undertaking. Understanding where to find the rules in theCode that apply to the installation is invaluable. Rules in several different articles often apply to even a simple installation. Article 90 then describes the scope and arrangement of the NEC. The balance of this article provides the reader with informa- tion essential to understanding the Code rules. Typically, electrical work requires you to understand the first four chapters of theNEC which apply generally, plus have a working knowledge of the Chapter 9 tables. That understanding begins with Article 90. Chapters 5, 6, and 7 make up a large portion of the Code, but they apply to special occupancies, special equipment, or other special conditions.
    [Show full text]
  • Electrical Code Amendment
    CITY OF GRAPEVINE Chapter 7, Buildings and Construction, Article III, Electrical Code ARTICLE III. ELECTRICAL CODE DIVISION 1. GENERALLY Sec. 7-30. Definitions. For the purposes of this article, hereinafter referred to as the electrical code or this code, the following terms, phrases, words, and their derivatives shall be construed as set out in this section: Approved: Acceptable to the building inspection division and/or the electrical board of appeals of the city. Authorized person: Any person, as defined in section 1-5, registered or licensed under the provisions of this code to do work as permitted under the specific provisions of this code. Buildings, building use: Words relating to buildings and building use, when not otherwise separately defined, shall have meanings which conform to the meanings set out in the zoning ordinance of the city; otherwise, they shall have their usual dictionary meanings. City: The territory within the corporate limits of the city, or the legally constituted governing body thereof, its agents and its officers. Conductor: A wire or cable or other form of metal suitable for carrying electric current or potential. Electrical apprentice: Any person who has been issued a license from the State of Texas as an electrical apprentice as provided for by state law. Electrical construction: All work and materials used in installing, maintaining, or extending a system of electrical wiring and all appurtenances, apparatus or equipment used in connection therewith, inside or outside of or attached to any building, structure, lot or premises. Electrical contractor: Any person who has been issued a license from the State of Texas as an electrical contractor as provided for by state law.
    [Show full text]
  • Industrial MI Wiring Cable
    Industrial MI Wiring Cable Installation Manual for Alloy 825 Sheath Cable Wiring Systems Important Safeguards and Warnings WARNING: FIRE AND SHOCK HAZARD. nVent PYROTENAX mineral insulated (MI) industrial wiring cables must be installed in accordance with the requirements of national and local codes and standards, the installation instructions in this manual, and the customer’s specification. Read these important safeguards and carefully follow the installation instructions. • Ensure the cable has been stored properly and is in good condition prior to commencing installation. • Always use safe working practices when installing cables, observing OSHA and other national safety rules. • Store cables indoors in a clean, dry, covered area, if possible. • During the time that the cables are exposed and during cable pulling activities, protect cables from nearby or overhead work to prevent damage to the cable sheath. • Do not pull cables around corners that have sharp edges, such as corners in cable trays, or other obstructions. • Prevent damage to cables by removing any abrasions or sharp edges from surface of support system. • Damage to cables or components can cause sustained electrical arcing or fire. Do not energize cables that have been damaged. Damaged cable or terminations may need to be repaired or replaced. Damaged cable should be repaired by a qualified person. • When installing cables which may be exposed to hydrocarbon flash fires, use only steel or stainless steel in the support system. ii | nVent.com Table of Contents General Information
    [Show full text]