CONSUMABLE CATALOG Onelab 1.12.1 CONSUMABLE CATALOG Onelab 1.12.1

Total Page:16

File Type:pdf, Size:1020Kb

CONSUMABLE CATALOG Onelab 1.12.1 CONSUMABLE CATALOG Onelab 1.12.1 SUM ON A C B L Y E B B Y E L C B O A N S U M CONSUMABLE CATALOG OneLab 1.12.1 CONSUMABLE CATALOG OneLab 1.12.1 OneLab Design & Execute Unique software for the design and execution of lab protocols. The pace of innovation in current day biological research demands the highest levels of reproducibility and traceability. Andrew Alliance, a Waters Company, has developed an intelligent cloud-based software environment called OneLab within which experiments can be intuitively designed, repeatably executed, and tracked through a rapidly evolving ecosystem of connected devices and accessories that it is building together with partner organisations. Andrew Alliance has developed the Andrew+ Pipetting Robot and the Pipette+ Intelligent Pipetting System, both of which seamlessly connect with OneLab. Andrew Alliance is an eco-friendly CO2-Neutral Certified Company, dedicated to developing sustainable solutions. Andrew Alliance is constantly adding new capabilities, accessories and consumables to OneLab as indicated by this catalog which is updated on a regular basis. 1 500 Compatible Incompatible « on-the-fly » : Numeric value : compatible only with minimum volume in uL on-the-fly dispensing which must be present in the consumable to avoid collisions. For more information about the care and use of Dominos and Devices, please check out our articles in the Andrew Alliance Help Center. https://help.andrewalliance.com 2 /170 CONSUMABLE CATALOG OneLab 1.12.1 TABLE OF CONTENTS WebSeal 2 mL 96-deep well U-bottom plate ..........................................................................88 BOTTLES & RESERVOIRS WHEATON® 500 μL 96-well U-bottom medium μLplate® ...................................................89 Agilent 6-column reagent reservoir ........................................................................................... 4 Axygen® 12-well reservoir, 12-channel trough ........................................................................ 5 Axygen® 8-well reservoir, 8-channel trough ............................................................................ 6 TIPS Sartorius 10 μL to 1200 μL Optifit non-filtered tips ...............................................................90 Axygen® 96 V-bottom single well reservoir ............................................................................. 7 Sartorius 10 μL to 1200 μL Safetyspace™ filter tips ...............................................................92 Clickbio, VBLOK 200 mL V-bottom reservoir ............................................................................ 8 Sartorius 10 mL Optifit non-filtered tips .................................................................................94 Corning® 500 mL easy-grip storage bottle ............................................................................. 9 DURAN® 100 mL clear glass bottle .........................................................................................10 Sartorius 5 mL Optifit non-filtered tips ...................................................................................95 DURAN® 250 mL clear glass bottle .........................................................................................11 Sartorius 5 mL Safetyspace™ filter tips ...................................................................................96 ILS, 12-channel reagent reservoir ............................................................................................12 INTEGRA 10 mL multichannel reservoir ..................................................................................13 Nalgene™ 125 mL narrow-mouth HDPE bottle ......................................................................14 TUBES & VIALS Nalgene™ 15 mL HDPE diagnostic bottle ................................................................................15 10 mL flat-bottom screw cap test tube ...................................................................................97 Nalgene™ 175 mL square wide-mouth HDPE bottle .............................................................16 13x84mm collection tube, virus preservation medium ........................................................98 Nalgene™ 60 mL narrow-mouth HDPE bottle ........................................................................17 16x100mm collection tube, COPAN UTM® medium.............................................................99 PYREX® 500 mL wide-mouth storage bottle ..........................................................................18 16x100mm collection tube, IMPROVIRAL™ medium ...........................................................101 16x100mm collection tube, virus preservation medium ....................................................102 ACC, Pyrotube® 16x90mm depyrogenated glass tube.......................................................103 CHIPS & DEVICES Agilent 2 mL crimp-top vial in Genevac 48x holder .............................................................104 24-well photoredox block assembly ........................................................................................19 Agilent 2 mL crimp-top vial in Waters 48x holder ................................................................105 24x 4 mL aluminum multi-well reaction block .......................................................................20 Axygen® 1.5 mL Maxymum Recovery® snaplock microtube ............................................106 24x 8 mL aluminum multi-well reaction block .......................................................................21 BRAND® 1.2 mL 8-strip tubes in 96x rack ............................................................................107 48x 2 mL aluminum multi-well reaction block .......................................................................22 CELLSTAR® 50 mL conical centrifuge tube ...........................................................................108 96-well photoredox block assembly ........................................................................................23 Charles River, 16×90mm endotoxin-free glass tube ...........................................................109 ProteinSimple, Wes/Jess plate ..................................................................................................24 Chemglass, 20 mL screw-top reaction vial............................................................................110 Unchained Labs, Big Lunatic plate ...........................................................................................25 Corning® 1.2 mL 8 cluster tube-strip in 96x rack ................................................................111 Corning® 50 mL conical centrifuge tube ..............................................................................112 Cryo.s™ 2 mL external thread tube in Waters 48x holder ..................................................113 COLUMNS EndoGrade® 5 mL glass test tube .........................................................................................114 Ostro protein precipitation & phospholipid removal 96-well plate .....................................27 ArcticWhite, 400 μL 96-well filter plate, hydrophilic PVDF, 0.45 μm ....................................28 Eppendorf 0.5 mL DNA LoBind® microtube ........................................................................115 MACHEREY-NAGEL, NucleoBond Xtra Midi column ...............................................................29 Eppendorf 1.5 mL Safe-Lock tube ..........................................................................................116 MACHEREY-NAGEL, NucleoSpin® 96 virus binding plate .....................................................30 Eppendorf 2 mL Safe-Lock tube .............................................................................................118 MultiScreen®HTS HV clear 96-well filter plate, 0.45 μm pore size ......................................31 Falcon® 14 mL round bottom test tube ...............................................................................119 Oasis HLB 96-square well plate, 30 mg sorbent/well ............................................................32 Falcon® 15 mL conical centrifuge tube.................................................................................120 Oasis HLB 96-square well plate, 60 mg sorbent/well ............................................................33 Falcon® 15 mL conical tube in Sapidyne 60x rack ..............................................................121 Oasis HLB 96-well μElution plate, 2 mg sorbent/well ............................................................34 Falcon® 5 mL round bottom test tube .................................................................................122 Oasis method development 96-well μElution plate, 2 mg sorbent/well .............................35 Falcon® 50 mL conical centrifuge tube.................................................................................123 Oasis PRiME HLB 96-well μElution plate, 3 mg sorbent/well ................................................36 Firmenich, 20 mL C15 B glass vial ..........................................................................................125 Oasis PRiME HLB 96-well plate, 10 mg sorbent/well .............................................................37 Fisherbrand™ 0.5 mL free-standing microtube ...................................................................126 Oasis PRiME HLB 96-well plate, 30 mg sorbent/well .............................................................38 Fisherbrand™ 2 mL skirted conical microtube .....................................................................127
Recommended publications
  • Determination of the Identity of an Unknown Liquid Group # My Name the Date My Period Partner #1 Name Partner #2 Name
    Determination of the Identity of an unknown liquid Group # My Name The date My period Partner #1 name Partner #2 name Purpose: The purpose of this lab is to determine the identity of an unknown liquid by measuring its density, melting point, boiling point, and solubility in both water and alcohol, and then comparing the results to the values for known substances. Procedure: 1) Density determination Obtain a 10mL sample of the unknown liquid using a graduated cylinder Determine the mass of the 10mL sample Save the sample for further use 2) Melting point determination Set up an ice bath using a 600mL beaker Obtain a ~5mL sample of the unknown liquid in a clean dry test tube Place a thermometer in the test tube with the sample Place the test tube in the ice water bath Watch for signs of crystallization, noting the temperature of the sample when it occurs Save the sample for further use 3) Boiling point determination Set up a hot water bath using a 250mL beaker Begin heating the water in the beaker Obtain a ~10mL sample of the unknown in a clean, dry test tube Add a boiling stone to the test tube with the unknown Open the computer interface software, using a graph and digit display Place the temperature sensor in the test tube so it is in the unknown liquid Record the temperature of the sample in the test tube using the computer interface Watch for signs of boiling, noting the temperature of the unknown Dispose of the sample in the assigned waste container 4) Solubility determination Obtain two small (~1mL) samples of the unknown in two small test tubes Add an equal amount of deionized into one of the samples Add an equal amount of ethanol into the other Mix both samples thoroughly Compare the samples for solubility Dispose of the samples in the assigned waste container Observations: The unknown is a clear, colorless liquid.
    [Show full text]
  • 15.0 Hazardous Waste Disposal
    LABORATORY SAFETY MANUAL Revised June 2018 Emergency Contact Information In case of emergency: 911 Security Services: (daytime) 705-474-7600 ext. 5555 (cell phone) 705-498-7244 Laboratory Safety Coordinator: 474-3450 ext. 4180 Emergency Procedures** Chemical Spill On Body • Rinse affected area immediately for 15 minutes using emergency shower, if required. • Care must be taken to avoid contamination with face and eye(s). In Eye(s) • Immediately flush eye(s) using emergency eyewash station for a minimum of 15 minutes. In Laboratory • Assess the scene. If the situation is beyond your capabilities, contact your supervisor. • If safe to do so, turn off any ignition sources if flammable material is present. • Use spill kits to assist in spill containment. • Dispose of waste material with other hazardous waste. Fire • If you hear the Fire Alarm ring continuously evacuate the building immediately. • If you hear the Fire Alarm ring intermittently be alert however evacuation is not necessary. • If Fire Alarm changes from intermittent to continuous evacuate immediately • If you detect a fire, do not attempt to extinguish it yourself unless you are capable and it is safe to do so. Report the injury/incident to your supervisor as soon as possible. ** This is to be used as a quick reference only. For more detailed information, please refer to section 8.0 Emergency Procedures. Laboratory Safety Manual – Nipissing University 2 Table of Contents Acknowledgements ...................................................................................................
    [Show full text]
  • Gas Generator Bottle Introduction SCIENTIFIC This Gas Generator Setup Provides an Easy Way to Generate and Collect Gas
    Gas Generator Bottle Introduction SCIENTIFIC This gas generator setup provides an easy way to generate and collect gas. Specific instructions are provided for the generation of hydrogen gas using zinc and acid. Concepts • Generation of gases • Water displacement Materials Hydrochloric acid solution, HCl, 3 M Glass plates or Sulfuric acid solution, H2SO4, 3 M Glass tubing Mossy zinc, Zn, 6 g Pneumatic trough Water, tap Rubber tubing Bent glass tubing* Silicone grease packet* Gas collecting bottles or tubes, 3 or 4 Thistle tube* Gas generator bottle* Two-hole rubber stopper* *Materials included. Safety Precautions Hydrochloric acid solution is toxic by ingestion and inhalation and is severely corrosive to skin, eyes and other tissues, as is sulfuric acid solu- tion. Hydrogen gas is a highly flammable gas and a severe fire hazard. Exercise extreme caution when testing the gas and keep the gas generator away from flames. Wear chemical splash goggles, chemical-resistant gloves, and a chemical-resistant apron. This activity requires the use of hazardous components and/or has the potential for hazardous reactions. Please review current Material Safety Data Sheets for additional safety, handling, and disposal information. Procedure 1. Set up the apparatus as shown in the figure to the right. Lubricate the glass tubing and thistle tube with silicone grease before inserting into the stopper. Make sure Thistle tube the water level is above the platform. Prepare bottles for collecting gas by water Two-hole rubber stopper displacement. To do this, fill each gas collecting bottle (or tube) over the brim with tap water, and then cover each with a flat glass plate.
    [Show full text]
  • Laboratory Equipment Reference Sheet
    Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position.
    [Show full text]
  • LOWERING COSTS and SIMPLIFYING WORKFLOW with the Automate 2550 SYSTEM
    HACETTEPE UNIVERSITY FACULTY OF MEDICINE HOSPITAL CENTRAL AND STAT LABORATORIES LOWERING COSTS AND SIMPLIFYING WORKFLOW WITH THE AutoMate 2550 SYSTEM Laboratory profile › 1,040-bed hospital located in Ankara, Turkey › Provides uninterrupted 24/7 inpatient, outpatient and emergency services › Employs 6 professors, 6 associate Hacettepe University Faculty of Medicine Hospital is one of the leading professors and 130 operators university hospitals in Turkey. The university is well known for its › Performs up to 6.5 million geographical location and adoption of ground breaking technologies. biochemistry and hormone While the reference site is preferred by a large number of patients, it is tests annually of particular interest to specific patient populations seeking test results › Processes up to 2 million tests from a variety of panels. With many different systems performing on instruments in more than hundreds of standard and specialized tests, the hospital’s laboratories 20 different units are driven to ensure the delivery of results without error, while › Operates a Beckman Coulter containing costs and managing workload burden. standalone AutoMate 2550 pre- For more than 16 years, the facility—which has been held up as an and post-analytical automation system in the biochemistry example of excellence in its own region, as well as all over the country— laboratory, along with a Power has been using a standalone automation system with an aliquoter Processor system with two feature. With this technology, it has enhanced patient satisfaction,
    [Show full text]
  • Chapter 2 2.1 Description of Kit Items
    Manual of SEAT Friendly MCL Kit 7 Chapter 2 2.1 Description of Kit Items S.No. Item Name Figure/Setup Uses (Quantity/ kit) 1. Storage box opens on both sides. Contains necessary 1. Wooden box apparatus for doing with revolving experiments. top 2. Revolving top containing (1) dispensing bottles and vials for easy access to chemicals. 1. As a container for keeping liquids. 2. Microbeaker (10 mL) (12) 1. As a container for use in electrochemical experiments, 3. Beaker (50 thermochemistry experiments mL) preparation of salts, etc. (3) Steps for use 1. Bore the rubber cork to fit the stem of Hirsch funnel. 2. Cut the filter paper to fit the mesh of the funnel. The size should exactly fit the mesh, 4. Micro- neither big nor small. filtration 3. Fit the cork with funnel in unit the mouth of the boiling tube (2) (having a side tube). 4. Transfer the solution to be filtrated to the funnel. 5. Press the bulb with hand to evacuate it and place it on the side tube of the boiling tube while keeping it pressed. 6. Release the pressure. The bulb will suck the air inside the boiling tube allowing fast filtration. 8 Manual of SEAT Friendly MCL Kit S.No. Item Name Figure/Setup Uses (Quantity/Kit) 1. The watch glass is used to hold solids when being 5. Watch glass weighed. (2) 2. It should never be heated. 1. Flat plate with multiple “wells” used as micro test tubes. 2. Contains 96 rectangular matrix. 3. Each well of a micro plate typically holds somewhere between a few to a few hundred microlitres of liquid.
    [Show full text]
  • Laboratory Supplies and Equipment
    Laboratory Supplies and Equipment Beakers: 9 - 12 • Beakers with Handles • Printed Square Ratio Beakers • Griffin Style Molded Beakers • Tapered PP, PMP & PTFE Beakers • Heatable PTFE Beakers Bottles: 17 - 32 • Plastic Laboratory Bottles • Rectangular & Square Bottles Heatable PTFE Beakers Page 12 • Tamper Evident Plastic Bottles • Concertina Collapsible Bottle • Plastic Dispensing Bottles NEW Straight-Side Containers • Plastic Wash Bottles PETE with White PP Closures • PTFE Bottle Pourers Page 39 Containers: 38 - 42 • Screw Cap Plastic Jars & Containers • Snap Cap Plastic Jars & Containers • Hinged Lid Plastic Containers • Dispensing Plastic Containers • Graduated Plastic Containers • Disposable Plastic Containers Cylinders: 45 - 48 • Clear Plastic Cylinder, PMP • Translucent Plastic Cylinder, PP • Short Form Plastic Cylinder, PP • Four Liter Plastic Cylinder, PP NEW Polycarbonate Graduated Bottles with PP Closures Page 21 • Certified Plastic Cylinder, PMP • Hydrometer Jar, PP • Conical Shape Plastic Cylinder, PP Disposal Boxes: 54 - 55 • Bio-bin Waste Disposal Containers • Glass Disposal Boxes • Burn-upTM Bins • Plastic Recycling Boxes • Non-Hazardous Disposal Boxes Printed Cylinders Page 47 Drying Racks: 55 - 56 • Kartell Plastic Drying Rack, High Impact PS • Dynalon Mega-Peg Plastic Drying Rack • Azlon Epoxy Coated Drying Rack • Plastic Draining Baskets • Custom Size Drying Racks Available Burn-upTM Bins Page 54 Dynalon® Labware Table of Contents and Introduction ® Dynalon Labware, a leading wholesaler of plastic lab supplies throughout
    [Show full text]
  • High School Chemistry
    RECOMMENDED MINIMUM CORE INVENTORY TO SUPPORT STANDARDS-BASED INSTRUCTION HIGH SCHOOL GRADES SCIENCES High School Chemistry Quantity per Quantity per lab classroom/ Description group adjacent work area SAFETY EQUIPMENT 2 Acid storage cabinet (one reserved exclusively for nitric acid) 1 Chemical spill kit 1 Chemical storage reference book 5 Chemical waste containers (Categories: corrosives, flammables, oxidizers, air/water reactive, toxic) 1 Emergency shower 1 Eye wash station 1 Fire blanket 1 Fire extinguisher 1 First aid kit 1 Flammables cabinet 1 Fume hood 1/student Goggles 1 Goggles sanitizer (holds 36 pairs of goggles) 1/student Lab aprons COMPUTER ASSISTED LEARNING 1 Television or digital projector 1 VGA Adapters for various digital devices EQUIPMENT/SUPPLIES 1 box Aluminum foil 100 Assorted rubber stoppers 1 Balance, analytical (0.001g precision) 5 Balance, electronic or manual (0.01g precision) 1 pkg of 50 Balloons, latex 4 Beakers, 50 mL 4 Beakers, 100 mL 2 Beakers, 250 mL Developed by California Science Teachers Association to support the implementation of the California Next Generation Science Standards. Approved by the CSTA Board of Directors November 17, 2015. Quantity per Quantity per lab classroom/ Description group adjacent work area 2 Beakers, 400 or 600 mL 1 Beakers, 1000 mL 1 Beaker tongs 1 Bell jar 4 Bottle, carboy round, LDPE 10 L 4 Bottle, carboy round, LDPE 4 L 10 Bottle, narrow mouth, 1000 mL 20 Bottle, narrow mouth, 125 mL 20 Bottle, narrow mouth, 250 mL 20 Bottle, narrow mouth, 500 mL 10 Bottle, wide mouth, 125
    [Show full text]
  • When Magnesium Metal Reacts with Hydrochloric Acid, Hydrogen Gas Is Produced
    Clements—Chemistry I H Molar Volume of a Gas When magnesium metal reacts with hydrochloric acid, hydrogen gas is produced. The volume of this gas can be measured by using a eudiometer. A eudiometer is a giant test tube that has graduated volume measurements. Knowing the number of moles of magnesium used, you can calculate the volume of hydrogen produced per mole of magnesium consumed. The balanced equation for this reaction also allows you to determine the volume that one mole of gas occupies as a recorded temperature and pressure. Procedure Half fill a tall cylinder with tap water, and place about 1O0mL of tap water in a 25O-mL beaker. Obtain ~1OmL of 3M hydrochloric acid in a graduated cylinder. Acquire a piece of magnesium ribbon and measure and record its mass to the nearest 0.OOlg. Roll the magnesium ribbon into a loose coil. Tie the coil with a piece of thread in such a manner that all of the loops of the coil are tied together. With a funnel, carefully pour ~10mL of 3M HCl (aq) into the eudiometer. Using the room temperature water in the 250-mL beaker, very slowly pour water from the beaker into the eudiometer which is in a slightly tipped position. Be careful to layer the water over the acid so that they do not mix thoroughly. Add enough water to fill the eudiometer completely. Using the thread, lower the magnesium coil into the water in the eudiometer to a depth of ~5cm. Insert the rubber stopper into the mouth of the eudiometer to hold the thread in position.
    [Show full text]
  • Microbiology. Applied to Protecting the Line
    3M Food Safety Division Microbiology. Applied to protecting the line www.3M.com/foodsafety/us Increase Productivity & Profitability to Your Business by 3M Food Safety Product Cost 45% Product Cost Saving Increase Productivity • 45% Reducing labor cost, saving utilities • Ability to increase productivity in food processing. and equipments of sample preparation 3M rapid solution help to detect contamination, • The shelf-stable, thin design takes up 85% less space faster time to results. Making faster decision. than agar dishes, freeing incubator and storage space and significantly reducing biohazardous waste • Control the production process better than ever. Higher product quality and Reduce overall costs, such as reducing waste, reducing Break down. OFF ON Fas te ISO r HACCP GMP Brand Protection Inventory Management • Establish brand credibility. Reliable • Release product to the hands of consumers faster. testing results with the global standard Company faster gaining profit • Reduce risk of product from the Recall • Reduce cost of storage inventory concerns. and Reject. Making trust from business partners. 2 Increase Laboratory Productivity by 3M Food Safety Product Product 3M Food Safety Cost 45% Cost Saving Accuracy • 45% Reduce the cost of labor, • Provide accurate results to Make decisions saving utilities and equipments correctly. Increase effectiveness of laboratory for sample preparation. • Build the credibility of laboratory with your • Reduce the cost of acquisition lab partners and auditors with the international equibments or the expansion of the method standards laboratory. Space less than 85% of Agar. Time 50% Software Time • Faster time to result.The product is designed to reduce steps and timing compared to the traditional method.
    [Show full text]
  • Fisherbrand Reusable Glassware Brochure
    Glassware Disposable, Reusable and Specialty Table of Contents Glassware Beakers ............................................................................................................................................................................................................... 1 Bottles ..............................................................................................................................................................................................................1-2 Media ........................................................................................................................................................................................................... 1 Storage .....................................................................................................................................................................................................1-2 Burets ...............................................................................................................................................................................................................2-3 Cells ..................................................................................................................................................................................................................4-5 Spectrophotometer .................................................................................................................................................................................
    [Show full text]
  • 3M™ Petrifilm™ Aerobic Count Plates Introduction SCIENTIFIC Petrifilm™ Plates Are Designed to Determine Total Aerobic Bacterial Populations
    3M™ Petrifilm™ Aerobic Count Plates Introduction SCIENTIFIC Petrifilm™ plates are designed to determine total aerobic bacterial populations. The easy-to-use BIO FAX! Petrifilm plates contain a film coated with nutrients and gelling agents. You will be able to monitor environmental bacterial counts using a variety of methods. Three environmental sampling methods are described as well as the standard inoculation procedure. Concepts • Microbiology • Plate counting Materials Petrifilm Aerobic Count Plates Incubator Petrifilm Spreader Pipet Chip clips Tape, double-sided Cotton swab, sterile Test tube, screwtop Safety Precautions Wear chemical-resistant gloves while working with microbial organisms. After use, Petrifilm Aerobic Count Plates will contain viable cultures. Do NOT reopen the Petrifilm plates or handle unnecessarily. Wash hands thoroughly with soap and water before leaving the laboratory. Extreme caution should be exercised when handling culture materials, and students should be trained in aseptic techniques. Always clean work areas and wash hands after working with microbiological materials. Procedures Standard Inoculation 1. Place the Petrifilm Aerobic Count Plate on a flat surface. Carefully peel open the Petrifilm plate being careful not to touch the nutrient gel with your fingers. (See Figure 1.) 2. With a pipet perpendicular to the Petrifilm plate, place 1 mL of sample (inoculum) onto the center of the bottom film. (See Figure 2.) 3. Release the top film; allow it to drop. Do not roll top film down. (See Figure 3.) Figure 1. Figure 2. Figure 3. FLAT side RIDGE side Figure 4. Figure 5. Figure 6. © 2016 Flinn Scientific, Inc. All Rights Reserved. Publication No. 10163 1 061616 3M™ Petrifilm™ Aerobic Count Plates continued 4.
    [Show full text]