Microbiology. Applied to Protecting the Line

Total Page:16

File Type:pdf, Size:1020Kb

Microbiology. Applied to Protecting the Line 3M Food Safety Division Microbiology. Applied to protecting the line www.3M.com/foodsafety/us Increase Productivity & Profitability to Your Business by 3M Food Safety Product Cost 45% Product Cost Saving Increase Productivity • 45% Reducing labor cost, saving utilities • Ability to increase productivity in food processing. and equipments of sample preparation 3M rapid solution help to detect contamination, • The shelf-stable, thin design takes up 85% less space faster time to results. Making faster decision. than agar dishes, freeing incubator and storage space and significantly reducing biohazardous waste • Control the production process better than ever. Higher product quality and Reduce overall costs, such as reducing waste, reducing Break down. OFF ON Fas te ISO r HACCP GMP Brand Protection Inventory Management • Establish brand credibility. Reliable • Release product to the hands of consumers faster. testing results with the global standard Company faster gaining profit • Reduce risk of product from the Recall • Reduce cost of storage inventory concerns. and Reject. Making trust from business partners. 2 Increase Laboratory Productivity by 3M Food Safety Product Product 3M Food Safety Cost 45% Cost Saving Accuracy • 45% Reduce the cost of labor, • Provide accurate results to Make decisions saving utilities and equipments correctly. Increase effectiveness of laboratory for sample preparation. • Build the credibility of laboratory with your • Reduce the cost of acquisition lab partners and auditors with the international equibments or the expansion of the method standards laboratory. Space less than 85% of Agar. Time 50% Software Time • Faster time to result.The product is designed to reduce steps and timing compared to the traditional method. Trend Analysis • Reduce unnecessary running time down to 50%. such as glass washing, agar • Software was designed effective preparation. 3M Rapid Solution is ready test plan.Can be aggregated and to use products analyzed. The information to be • Make your time to money-Other aspects, derived risk assessment for such as request the quality standards such management, effectively as ISO17025, BRC Lab Efficiency • 80% Increasing QA personnel efficiency • Improves consistency across technicians, shifts and plants 3 Water-soluble gelling agents. Applied to advancing agility. Over 30 years, food safety professionals around the world have put their trust in 3M Petrifilm™ Plates. That’s because these ingenious “little red dots” have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality. 3M Petrifilm™ 3M Petrifilm™ 3M Petrifilm™ Rapid Aerobic Count Plate Aerobic Count Plate Plate Reader (PPR) • Broad performance for food, • Easy interpretation-Red Colonies • Fast results in just 4 seconds per plate Beverage & Environmental samples • Broad performance for in Food, • Eliminates variation between technicians • Fast results. Get accurate results in Beverage & Environmental samples • Reduces the chance for human error 24 hours (excluding dairy powders). • Provide accurate, efficient, • Reads bar code labels consistent results in 48 hours. • Improves data 3M Petrifilm™ 3M Petrifilm™ 3M Petrifilm™ Enterobacteriaceae Count Plate Coliform Count Plate Rapid Coliform Count Plate • Easy interpretation-Red • Easy interpretation-Red Colonies • High coliform contamination can be Colonies, yellow colored zones with gas bubbles detected beginning at 4 hours with (acid), with or w/o gas bubbles • Provide accurate, efficient, consistent distinctive yellow zones. • Provide accurate, efficient, results in 24 hours. • Presumptive coliforms may be recorded consistent results in 24 hours. • Broad performance for Food, Beverage at 14 hours. • Identify contamination- in Food, & Environmental samples. • Confirming results are available at 24 hours. Beverage & Environment samples 3M Petrifilm™ 3M Petrifilm™ 3M Petrifilm™ High-Sensitivity Coliform Count Plate E.Coli/Coliform Count Plate SELECTIVE E.Coli Count Plate • accommodates 5 mL samples • 2 in 1 for detect E.coli & Coliforms • Fast results. Get accurate and detection of low levels of confirmed • Confirmed Coliform andE. coli results in 24 hours. coliforms in 24 hours. results in 24-48 hours. • Broad performance for all Food • Broad performance for Food, and Beverage. Beverage & Environmental samples. • Enumerate - E coli colonies are blue 4 Simple Prompt. Precise. Productive. 3M Petrifilm™ Rapid 3M Petrifilm™ 3M Petrifilm™ 3M Petrifilm™ Environmental Yeast & Mold Count Plate Yeast & Mold Count Plate Staph Express Count Plate Listeria Count Plate • Provide accurate, efficient, • Provide accurate, efficient, • Provide accurate, efficient, • Rapid results in 27-31 hours consistent results in 48 hours. consistent results in 3-5 days consistent results in 24 hours. from sample collection. • Proven as reliable as DRBC and • Identify yeast & mold in Food, • ConfirmStaphyloccoccus • Safer method: no enrichment, DG-18 spread plate methods, Beverage & Environmental aureus -Red-violet colonies. no culture transfers. as well as acidified PDA and samples. • Disk can be used to identify • Quantitative results allow YGC agar pour plate methods • Yeasts Colonies: small, blue - Staph aureus from all suspect identification of hot spots • Can be used with both low and green colonies with defined colonies. in plant and track progress high water activity food edges & no foci. against Listeria over time. • Broad performance for Food • Mold Colonies: large, variably- & Beverage & Environmental colored colonies with diffuse samples. edges & center foci. Water Testing Maximized 3M Petrifilm™ Aqua Plates are sample-ready media that replace conventional agar, petri dishes, media pads and disposable filter funnels used in the microbial testing of water. Each plate contains a water-soluble gelling agent, nutrients and indicators in a dry, shelf-stable format. 3M Petrifilm™ Aqua 3M Petrifilm™ Aqua 3M Petrifilm™ AQUA 3M Petrifilm™ AQUA Heterotrophic Count Plate Coliform Count Plate Yeast & Mold Count Plate Enterobacteriaceae Count Plate (AQHC) (AQCC) (AQYM) (AQEB) • Utilizes the convenience and • Utilizes the convenience and • Utilizes the convenience and • Utilizes the convenience and efficiency of the 3M Petrifilm™ efficiency of the 3M Petrifilm™ efficiency of the 3™ Petrifilm™ efficiency of the 3M Petrifilm™ Plate platform. Plate platform. Plate platform. Plate platform. • Provide fast, accurate results in • Deliver reliable testing results • Provide fast, accurate results in • Detects Enterobacteriaceae enumerating heterotrophic for your bottled water. enumeration of yeast and mold in bottled water. bacteria in the bottled water • Confirm coliform results in in bottled water industries. • Results in 24 hrs.. industry. 24 hrs. • Results in 3-5 days. • Results in 48 hrs. 5 Isothermal DNA amplification. Applied to protecting the process. 3M Molecular Detection Instrument • Smaller footprint than a standard notebook computer that requires significantly less space than the market leading rapid methods. • Robust instrument that is solid state, portable with no need for recalibration, requires minimal maintenance, and provides automatic diagnostics at start up. • Powerful software that allows operation of up to four instruments simultaneously from one computer. 3M Molecular Detection Assay 3M Molecular Detection Assay 3M Molecular Detection Salmonella Listeria Matrix Control • Utilizes the convenience and efficiency of • Utilizes the convenience and efficiency of • Verify that new or unknown matrices are not the 3M Molecular Detection System platform. the 3M Molecular Detection System platform. inhibitory to amplification. • Proven cost effective tool for the detection • Proven cost effective tool for the detection • Ready-to-use and pre-dispensed reagents. of Salmonella in enriched food, feed and of Listeria in enriched food and environmental • Only two transfer steps after enrichment. food process environmental samples. samples. • Closed-tube system reduces risk of amplicon contamination. 3M Molecular Detection Assay 3M Molecular Detection Assay 3M Buffered Peptone Water Broth (ISO) E.coli O157 (inc. H7) L.monocytogenes 3M Modified Listeria Recovery • Utilizes the convenience and efficiency of • Utilizes the convenience and efficiency of Broth/Supplement the 3M Molecular Detection System platform. the 3M Molecular Detection System platform. • Proven cost effective tool for the detection • Proven cost effective tool for the detection • 3M dehydrated media assist in keeping of E. coli O157, including H7, in enriched of Listeria monocytogenes in enriched foo your lab practices. food samples. and environmental samples. • Convenient: flexibility of options, make what you need when you need it. • Easy. Consistent. 6 Introducing the next generation of 3M Molecular Detecion Assays: Isothermal DNA Amplification and Bioluminescence Detection — to bring you the next generation of 3M Molecular Detection Assays for an accurate reliable molecular solution with increased productivity. Allowing you to make critical decisions faster, streamline your process and protect your business — and your bottom line. 3M Molecular Detection Assay 2 3M Molecular Detection Assay 2 3M Molecular Detection Assay 2 - Salmonella - Listeria - E.coli O157 (inc. H7) • One assay protocol and fewer steps than • One assay protocol and fewer steps than • One assay protocol and fewer steps than most tests reduces
Recommended publications
  • Determination of the Identity of an Unknown Liquid Group # My Name the Date My Period Partner #1 Name Partner #2 Name
    Determination of the Identity of an unknown liquid Group # My Name The date My period Partner #1 name Partner #2 name Purpose: The purpose of this lab is to determine the identity of an unknown liquid by measuring its density, melting point, boiling point, and solubility in both water and alcohol, and then comparing the results to the values for known substances. Procedure: 1) Density determination Obtain a 10mL sample of the unknown liquid using a graduated cylinder Determine the mass of the 10mL sample Save the sample for further use 2) Melting point determination Set up an ice bath using a 600mL beaker Obtain a ~5mL sample of the unknown liquid in a clean dry test tube Place a thermometer in the test tube with the sample Place the test tube in the ice water bath Watch for signs of crystallization, noting the temperature of the sample when it occurs Save the sample for further use 3) Boiling point determination Set up a hot water bath using a 250mL beaker Begin heating the water in the beaker Obtain a ~10mL sample of the unknown in a clean, dry test tube Add a boiling stone to the test tube with the unknown Open the computer interface software, using a graph and digit display Place the temperature sensor in the test tube so it is in the unknown liquid Record the temperature of the sample in the test tube using the computer interface Watch for signs of boiling, noting the temperature of the unknown Dispose of the sample in the assigned waste container 4) Solubility determination Obtain two small (~1mL) samples of the unknown in two small test tubes Add an equal amount of deionized into one of the samples Add an equal amount of ethanol into the other Mix both samples thoroughly Compare the samples for solubility Dispose of the samples in the assigned waste container Observations: The unknown is a clear, colorless liquid.
    [Show full text]
  • METHODS & STANDARD OPERATING PROCEDURES (Sops)
    METHODS & STANDARD OPERATING PROCEDURES (SOPs) OF EMISSION TESTING IN HAZARDOUS WASTE INCINERATOR FOREWARD COVR PAGE TEAM CHAPTER TITLE PAGE NO Chapter - 1 Stack Monitoring – Material And Methodology For Isokinetic Sampling 1-28 Chapter - 2 Standard Operating Procedure (SOP) For Particulate Matter Determination 29-38 Chapter - 3 Determination Of Hydrogen Halides (Hx) And Halogens From Source Emission 39-54 Chapter - 4 Standard Operating Procedure For The Sampling Of Hydrogen Halides And Halogens From Source Emission 55-61 Determination Of Metals And Non Metals Emissions From Chapter - 5 Stationarysources 62-79 Standard Operating Procedure (Sop) For Sampling Of Metals And Non Chapter - 6 Metals & 80-97 Standard Operating Procedure (Sop) Of Sample Preparation For Analysis Of Metals And Non Metals Chapter - 7 Determination Of Polychlorinated Dibenzo-P-Dioxins And 98-127 Polychlorinated Dibenzofurans Standard Operating Procedure For Sampling Of Polychlorinated Chapter - 8 Dibenzo-P-Dioxins And Polychlorinated Dibenzofurans & 128-156 Standard Operating Procedure For Analysis Of Polychlorinated Dibenzo- P-Dioxins And Polychlorinated Dibenzofurans Project Team 1. Dr. B. Sengupta, Member Secretary - Overall supervision 2. Dr. S.D. Makhijani, Director - Report Editing 3. Sh. N.K. Verma, Ex Additional Director - Project co-ordination 4. Sh. P.M. Ansari, Additional Director - Report Finalisation 5. Dr. D.D. Basu, Senior Scientist - Guidance and supervision 6. Sh. Paritosh Kumar, Sr. Env. Engineer - Report processing 7. Sh. Dinabandhu Gouda, Env. Engineer - Data compilation, analysis and preparation of final report 8. Sh. G. Thirumurthy, AEE - - do - 9. Sh. Abhijit Pathak, SSA - - do - 10. Ms. Trapti Dubey, Jr. Professional (Scientist) - - do - 11. Er. Purushotham, Jr. Professional (Engineer) - - do - 12.
    [Show full text]
  • Laboratory Equipment Reference Sheet
    Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position.
    [Show full text]
  • Eight New Filter Bags from Whirl-Pak® Three New Hydrated Sponge
    NEW PRODUCTS Eight new filter bags from whirl-pak® Specially designed for use with homogenizer blenders. Extra-heavy PET film and special features for easier and more efficient testing. Additional sizes and styles on page 11. Vertical Filter Bags Bags use a special laminated PET film for durability and a vertical nonwoven filter to separate solids for easy pipetting of the liquid sample. Available with or without a closure, each bag contains a 250 micron polyester filter adhered vertically along the side of the 3 mil (0.76 mm) bag. Easy-pour side seal allows you to simply pour liquid out of the bag without also emptying solids. Hydrated PolySponge™ Bags B01586 — 55 oz. With Closure three new Hydrated sponge products from whirl-pak® Make environmental surface sampling faster and easier with these pre-moistened bags. Durable high-density polyurethane sponge is ready to use and resists tearing and fraying. Each is hydrated with HiCap™ Neutralizing Broth. Additional information on page 12. Hydrated PolyProbe™ HiCap™ is a registered trademark of World Bioproducts, LLC. ctured under a ufa qua n li Whirl-Pak® Bags are manufactured under a quality management system certified to ISO9001, except B01299, B01350, a t y M m o , , , , , , , and which require an additional processing step an t B01392 B01422 B01423 B01475 B01478 B01590 B01591 B01592 age fied ISO9001ment system certi done outside of regular production. • Standard Methods Says — Standard Methods (18th edition, 1992, section 9060A, sample containers) states “For some applications, samples may be collected in pre-sterilized plastic bags.” Whirl-Pak® bags meet this description.
    [Show full text]
  • LOWERING COSTS and SIMPLIFYING WORKFLOW with the Automate 2550 SYSTEM
    HACETTEPE UNIVERSITY FACULTY OF MEDICINE HOSPITAL CENTRAL AND STAT LABORATORIES LOWERING COSTS AND SIMPLIFYING WORKFLOW WITH THE AutoMate 2550 SYSTEM Laboratory profile › 1,040-bed hospital located in Ankara, Turkey › Provides uninterrupted 24/7 inpatient, outpatient and emergency services › Employs 6 professors, 6 associate Hacettepe University Faculty of Medicine Hospital is one of the leading professors and 130 operators university hospitals in Turkey. The university is well known for its › Performs up to 6.5 million geographical location and adoption of ground breaking technologies. biochemistry and hormone While the reference site is preferred by a large number of patients, it is tests annually of particular interest to specific patient populations seeking test results › Processes up to 2 million tests from a variety of panels. With many different systems performing on instruments in more than hundreds of standard and specialized tests, the hospital’s laboratories 20 different units are driven to ensure the delivery of results without error, while › Operates a Beckman Coulter containing costs and managing workload burden. standalone AutoMate 2550 pre- For more than 16 years, the facility—which has been held up as an and post-analytical automation system in the biochemistry example of excellence in its own region, as well as all over the country— laboratory, along with a Power has been using a standalone automation system with an aliquoter Processor system with two feature. With this technology, it has enhanced patient satisfaction,
    [Show full text]
  • Chapter 2 2.1 Description of Kit Items
    Manual of SEAT Friendly MCL Kit 7 Chapter 2 2.1 Description of Kit Items S.No. Item Name Figure/Setup Uses (Quantity/ kit) 1. Storage box opens on both sides. Contains necessary 1. Wooden box apparatus for doing with revolving experiments. top 2. Revolving top containing (1) dispensing bottles and vials for easy access to chemicals. 1. As a container for keeping liquids. 2. Microbeaker (10 mL) (12) 1. As a container for use in electrochemical experiments, 3. Beaker (50 thermochemistry experiments mL) preparation of salts, etc. (3) Steps for use 1. Bore the rubber cork to fit the stem of Hirsch funnel. 2. Cut the filter paper to fit the mesh of the funnel. The size should exactly fit the mesh, 4. Micro- neither big nor small. filtration 3. Fit the cork with funnel in unit the mouth of the boiling tube (2) (having a side tube). 4. Transfer the solution to be filtrated to the funnel. 5. Press the bulb with hand to evacuate it and place it on the side tube of the boiling tube while keeping it pressed. 6. Release the pressure. The bulb will suck the air inside the boiling tube allowing fast filtration. 8 Manual of SEAT Friendly MCL Kit S.No. Item Name Figure/Setup Uses (Quantity/Kit) 1. The watch glass is used to hold solids when being 5. Watch glass weighed. (2) 2. It should never be heated. 1. Flat plate with multiple “wells” used as micro test tubes. 2. Contains 96 rectangular matrix. 3. Each well of a micro plate typically holds somewhere between a few to a few hundred microlitres of liquid.
    [Show full text]
  • Laboratory Supplies and Equipment
    Laboratory Supplies and Equipment Beakers: 9 - 12 • Beakers with Handles • Printed Square Ratio Beakers • Griffin Style Molded Beakers • Tapered PP, PMP & PTFE Beakers • Heatable PTFE Beakers Bottles: 17 - 32 • Plastic Laboratory Bottles • Rectangular & Square Bottles Heatable PTFE Beakers Page 12 • Tamper Evident Plastic Bottles • Concertina Collapsible Bottle • Plastic Dispensing Bottles NEW Straight-Side Containers • Plastic Wash Bottles PETE with White PP Closures • PTFE Bottle Pourers Page 39 Containers: 38 - 42 • Screw Cap Plastic Jars & Containers • Snap Cap Plastic Jars & Containers • Hinged Lid Plastic Containers • Dispensing Plastic Containers • Graduated Plastic Containers • Disposable Plastic Containers Cylinders: 45 - 48 • Clear Plastic Cylinder, PMP • Translucent Plastic Cylinder, PP • Short Form Plastic Cylinder, PP • Four Liter Plastic Cylinder, PP NEW Polycarbonate Graduated Bottles with PP Closures Page 21 • Certified Plastic Cylinder, PMP • Hydrometer Jar, PP • Conical Shape Plastic Cylinder, PP Disposal Boxes: 54 - 55 • Bio-bin Waste Disposal Containers • Glass Disposal Boxes • Burn-upTM Bins • Plastic Recycling Boxes • Non-Hazardous Disposal Boxes Printed Cylinders Page 47 Drying Racks: 55 - 56 • Kartell Plastic Drying Rack, High Impact PS • Dynalon Mega-Peg Plastic Drying Rack • Azlon Epoxy Coated Drying Rack • Plastic Draining Baskets • Custom Size Drying Racks Available Burn-upTM Bins Page 54 Dynalon® Labware Table of Contents and Introduction ® Dynalon Labware, a leading wholesaler of plastic lab supplies throughout
    [Show full text]
  • Protecting Consumers. Improving Lab Efficiency. 3M™ Petrifilm™ Plates and Reader Simply Brilliant
    Protecting Consumers. Improving lab efficiency. 3M™ Petrifilm™ Plates and Reader Simply brilliant. This red dot changed microbiology. Imagine what it can do for your lab. In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, you want your lab to provide tests that are fast, reliable and consistently accurate. For more than 30 years, food safety professionals around the world have put their trust in 3M™ P e t r i fi l m ™ Plates. That’s because these ingenious “little red dots” have streamlined, standarised and simplifi ed the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality. Simply effi cient. Maximise productivity Improve consistency Plates are sample-ready, eliminating the time-consuming, cumbersome step of Compared to the variability associated with agar preparation, 3M’s preparing agar dishes. Plus, plates such as the E.coli/Coliform Count and Staph standardised formula improves consistency across technicians, shifts and Express Count plates go even further by eliminating the need for a subsequent plants – worldwide. Each lot of Petrifi lm plates goes through rigorous quality confi rmation step required with traditional agar methods. In a study conducted testing at our ISO 9001 certifi ed manufacturing facility. This reduces the need with 292 food-processing plants, companies increased their QA personnel for lot qualifi cations in operations making their own agar. More than 200 effi ciency by an average of 80.5%, saving an average of 3.7 hours per day of evaluations from peer-review publications and validating agencies worldwide technician time by using 3M™ Petrifi lm™ Plates.
    [Show full text]
  • High School Chemistry
    RECOMMENDED MINIMUM CORE INVENTORY TO SUPPORT STANDARDS-BASED INSTRUCTION HIGH SCHOOL GRADES SCIENCES High School Chemistry Quantity per Quantity per lab classroom/ Description group adjacent work area SAFETY EQUIPMENT 2 Acid storage cabinet (one reserved exclusively for nitric acid) 1 Chemical spill kit 1 Chemical storage reference book 5 Chemical waste containers (Categories: corrosives, flammables, oxidizers, air/water reactive, toxic) 1 Emergency shower 1 Eye wash station 1 Fire blanket 1 Fire extinguisher 1 First aid kit 1 Flammables cabinet 1 Fume hood 1/student Goggles 1 Goggles sanitizer (holds 36 pairs of goggles) 1/student Lab aprons COMPUTER ASSISTED LEARNING 1 Television or digital projector 1 VGA Adapters for various digital devices EQUIPMENT/SUPPLIES 1 box Aluminum foil 100 Assorted rubber stoppers 1 Balance, analytical (0.001g precision) 5 Balance, electronic or manual (0.01g precision) 1 pkg of 50 Balloons, latex 4 Beakers, 50 mL 4 Beakers, 100 mL 2 Beakers, 250 mL Developed by California Science Teachers Association to support the implementation of the California Next Generation Science Standards. Approved by the CSTA Board of Directors November 17, 2015. Quantity per Quantity per lab classroom/ Description group adjacent work area 2 Beakers, 400 or 600 mL 1 Beakers, 1000 mL 1 Beaker tongs 1 Bell jar 4 Bottle, carboy round, LDPE 10 L 4 Bottle, carboy round, LDPE 4 L 10 Bottle, narrow mouth, 1000 mL 20 Bottle, narrow mouth, 125 mL 20 Bottle, narrow mouth, 250 mL 20 Bottle, narrow mouth, 500 mL 10 Bottle, wide mouth, 125
    [Show full text]
  • Manual on Laboratory Testing of Fishery Products
    ISSN: 1995-4875 CRFM Special Publication. No.14 Manual on Laboratory Testing of Fishery Products The SPS Project is funded by the European Union under the 10th Economic Development Fund and is being implemented by the Inter-American Institute for Cooperation on Agriculture (IICA) with the following regional Partners: the CARICOM Secretariat, the Caribbean Regional Fisheries Mechanism (CRFM), El Comité Nacional para la Aplicació n de Medidas Sanitarias y Fitosanitarias de la Repú blica Dominicana (CNMSF) and CARIFORUM. Manual on Laboratory Testing of Fisheries Products Copyright © 2016 by Caribbean Regional Fisheries Mechanism (CRFM) All rights reserved. Reproduction, dissemination and use of material in this publication for educational or non- commercial purposes are authorized without prior written permission of the CRFM, provided the source is fully acknowledged. No part of this publication may be reproduced, disseminated or used for any commercial purposes or resold without the prior written permission of the CRFM. Prepared by: Christine Froese, Megapesca Lda., December 2016, under contract to the Inter- American Institute for Cooperation on Agriculture (IICA), through the 10th EDF funded Sanitary and Phytosanitary Project Correct Citation: Froese, C, 2016. Manual on Laboratory Testing of Fishery Products. CRFM Special Publication. No.14. 89pp. ISSN: 1995-4875 ISBN: 978-976-8257-38-3 Cover Photo: Fishery Product Testing Laboratory, Saint Vincent Contents 1 INTRODUCTION ...............................................................................................................................
    [Show full text]
  • Next Generation Microbiology for the Future
    Next Generation Microbiology for the Future www.msk.or.kr | 1 2014 INTERNATIONAL MEETING of the MICROBIOLOGICAL SOCIETY of KOREA 2 | 2014 International Meeting of the Microbiological Society of Korea 2014 INTERNATIONAL MEETING of Next Generationthe MICROBIOLOGICAL Microbiology for the Future SOCIETY of KOREA Contents • Timetable ············································································································································ 4 • Floor Plan ··········································································································································· 5 • Scientific Programs ···························································································································· 6 • Plenary Lectures······························································································································· 23 PL1 ······································································································································· 24 PL2 ······································································································································· 25 PL3 ······································································································································· 26 PL4 ······································································································································· 27 • Symposia ··········································································································································
    [Show full text]
  • When Magnesium Metal Reacts with Hydrochloric Acid, Hydrogen Gas Is Produced
    Clements—Chemistry I H Molar Volume of a Gas When magnesium metal reacts with hydrochloric acid, hydrogen gas is produced. The volume of this gas can be measured by using a eudiometer. A eudiometer is a giant test tube that has graduated volume measurements. Knowing the number of moles of magnesium used, you can calculate the volume of hydrogen produced per mole of magnesium consumed. The balanced equation for this reaction also allows you to determine the volume that one mole of gas occupies as a recorded temperature and pressure. Procedure Half fill a tall cylinder with tap water, and place about 1O0mL of tap water in a 25O-mL beaker. Obtain ~1OmL of 3M hydrochloric acid in a graduated cylinder. Acquire a piece of magnesium ribbon and measure and record its mass to the nearest 0.OOlg. Roll the magnesium ribbon into a loose coil. Tie the coil with a piece of thread in such a manner that all of the loops of the coil are tied together. With a funnel, carefully pour ~10mL of 3M HCl (aq) into the eudiometer. Using the room temperature water in the 250-mL beaker, very slowly pour water from the beaker into the eudiometer which is in a slightly tipped position. Be careful to layer the water over the acid so that they do not mix thoroughly. Add enough water to fill the eudiometer completely. Using the thread, lower the magnesium coil into the water in the eudiometer to a depth of ~5cm. Insert the rubber stopper into the mouth of the eudiometer to hold the thread in position.
    [Show full text]