Electrically-Compatible PV Modules

Total Page:16

File Type:pdf, Size:1020Kb

Electrically-Compatible PV Modules TECHNICAL BRIEF Electrically-Compatible PV Modules Updated 08/01/2012 The photovoltaic (PV) modules on this list have been verified for electrical compatibility with Enphase Microinverters over the cell temperature range of -25C to +75C. This document is intended as a means of reference and is not an exhaustive list of compatible modules. For applications outside of this temperature range, the system designer should verify that the module voltage and/or current would not exceed the microinverter model's nameplate ratings under all expected environmental conditions. The module specification sheet contains all of the necessary module information to make this determination. The ASHRAE Handbook (www.ashrae.org) is the recommended source for weather data. Check for updates to this document at http://www.enphase.com/support/downloads. Electrical versus Mechanical Compatibility The modules on this list are not verified for mechanical compatibility with Enphase Microinverters. To ensure mechanical compatibility, be sure to order the correct connector type for both microinverter and PV module from your distributor. CAUTION regarding Mechanical Compatibility of DC Connectors: Be aware that inclusion on this list indicates electrical compatibility, but does not guarantee mechanical compatibility of the PV module connectors. Be sure to order the correct connector type for both microinverter and PV module from your distributor. Enphase Microinverters must be ordered for specific module connector types. Microinverters are manufactured with two types of DC connectors for mating with PV modules. These are MC-4 and Tyco connectors. The polarity of the DC connectors on the microinverter varies with the type of connector: • When your microinverters are built with MC-4 compatible (S12/S22) connectors: The positive DC output of the PV module (+) connects to the microinverter connector labeled negative (-). • When your microinverters are built with Tyco (S13/S23) connectors: The positive DC output of the PV module (+) connects to the microinverter connector labeled positive (+). However, Tyco connectors can vary in polarity. With Tyco connectors either the male or female connector may be positive, but only the MALE positive will mate with Enphase Microinverters with S13/S23 connectors. Be sure to order the correct connector type for both microinverter and PV module from your distributor. As a rule, the electrically-positive output of the PV module always connects to the positive input of the microinverter. However, PV modules come with a variety of labels. For more information, refer to “Mating Microinverters with PV Modules for Correct Polarity” under the Enphase downloads at http://www.enphase.com/support/downloads. During installation, the status LED of each microinverter emits six green blinks one to two minutes after DC power is applied. This verifies normal operation and correct polarity of connections. 1 Copyright © 2012 Enphase Energy 08/01/2012 Electrically-Compatible PV Modules Determining Appropriate Module Size The appropriate module power rating for a given application depends on the specifics of that installation. Our paper, PV Module “Module Rightsizing” for Microinverters (see “Whitepapers” under the Enphase downloads at http://www.enphase.com/support/downloads), outlines specific factors to consider when determining optimum module power rating. A generally accepted practice is to use a module with an STC power rating of 1.2 times the AC power output rating of the inverter. Many system designers use a multiplier of 1.25 or 1.3. For an M190 Microinverter, this would suggest a module power rating of 228W to 250W (STC). The M215 should be paired with modules up to 265W (STC). Electrically-Compatible PV Modules The following table lists PV modules that are electrically compatible with Enphase Microinverters. Columns one and two list the brand and model for each PV module. Column three lists the Enphase Microinverter models that can be paired with that PV module. WARNING: The Enphase M215 Microinverter works ONLY with 60-cell modules. Damage to equipment can occur if the M215 is connected to a 72-cell module. In the list below, any 72-cell (or higher) modules are noted as being compatible only with other Enphase Microinverters. Electrically-Compatible PV Modules Manufacturer Name Model Number Enphase Microinverter 1Soltech 1STH-235 M215, M190 or D380 1Soltech 1STH-240 M215, M190 or D380 1Soltech 1STH-245 M215, M190 or D380 1Soltech 1STH-250 M215, M190 or D380 AIDE Solar XZST-155W/24V M190 or D380 AIDE Solar XZST-160W/24V M190 or D380 AIDE Solar XZST-165W/24V M190 or D380 AIDE Solar XZST-170W/24V M190 or D380 AIDE Solar XZST-175W/24V M190 or D380 AIDE Solar XZST-180W/24V M190 or D380 AIDE Solar XZST-185W/24V M190 or D380 AIDE Solar XZST-220W M215, M190 or D380 AIDE Solar XZST-220W(M) M215, M190 or D380 AIDE Solar XZST-230W M215, M190 or D380 AIDE Solar XZST-230W(M) M215, M190 or D380 aleo solar AG S_18.210 M215, M190 or D380 aleo solar AG S_18.215 M215, M190 or D380 aleo solar AG S_18.220 M215, M190 or D380 aleo solar AG S_18.225 M215, M190 or D380 aleo solar AG S_18.230 M215, M190 or D380 aleo solar AG S18U240 M215, M190 or D380 aleo solar AG S18U245 M215, M190 or D380 aleo solar AG S18U250 M215, M190 or D380 aleo solar AG S70U245 M215, M190 or D380 aleo solar AG S79U235 M215, M190 or D380 aleo solar AG S79U240 M215, M190 or D380 Alps Technology Inc ATI 1650-155 M190 or D380 Alps Technology Inc ATI 1650-165 M190 or D380 Alps Technology Inc ATI 1650-175 M190 or D380 2 Copyright © 2012 Enphase Energy 08/01/2012 Electrically-Compatible PV Modules Electrically-Compatible PV Modules Manufacturer Name Model Number Enphase Microinverter American Solar ASW-230P M215, M190 or D380 American Solar ASW-235M M215, M190 or D380 American Solar ASW-235P M215, M190 or D380 American Solar ASW-240M M215, M190 or D380 American Solar ASW-240P M215, M190 or D380 American Solar ASW-250M M215, M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-5M-160 M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-5M-165 M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-5M-170 M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-5M-175 M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-5M-180 M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-5M-185 M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-6M30-200 M215, M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-6M30-210 M215, M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-6M30-220 M215, M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-6M30-230 M215, M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-6M30-240 M215, M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-6M30-250 M215, M190 or D380 Amerisolar (Worldwide Energy & Mfg USA) AS-6P30-240 M215, M190 or D380 Andalay Solar, Inc. ST175-1 M190 or D380 Antaris Solar AS P6 230 M215, M190 or D380 Antaris Solar AS P6 235 M215, M190 or D380 Antaris Solar AS P6 240 M215, M190 or D380 ASP (Advanced Solar Photonics) AP-220PK M215, M190 or D380 ASP (Advanced Solar Photonics) AP-225PK M215, M190 or D380 ASP (Advanced Solar Photonics) AP-230PK M215, M190 or D380 ASP (Advanced Solar Photonics) AP-235PK M215, M190 or D380 ASP (Advanced Solar Photonics) AP-240PK M215, M190 or D380 ASP (Advanced Solar Photonics) Blackstar ASP-240M M215, M190 or D380 ASP (Advanced Solar Photonics) Blackstar ASP-245M M215, M190 or D380 Astronergy CHSM 6610M-205 M215, M190 or D380 Astronergy CHSM 6610M-210 M215, M190 or D380 Astronergy CHSM 6610M-215 M215, M190 or D380 Astronergy CHSM 6610M-220 M215, M190 or D380 Astronergy CHSM 6610M-225 M215, M190 or D380 Astronergy CHSM 6610M-230 M215, M190 or D380 Astronergy CHSM 6610M-235 M215, M190 or D380 Astronergy CHSM 6610M-240 M215, M190 or D380 Astronergy CHSM 6610M-245 M215, M190 or D380 Astronergy CHSM 6610M-250 M215, M190 or D380 Astronergy CHSM 6610M-250 Wp M215, M190 or D380 Astronergy CHSM 6610M-255 Wp M215 Astronergy CHSM 6610M-260 Wp M215 Astronergy CHSM 6610M(BL)-220 M215, M190 or D380 Astronergy CHSM 6610M(BL)-225 M215, M190 or D380 Astronergy CHSM 6610M(BL)-230 M215, M190 or D380 Astronergy CHSM 6610M(BL)-235 M215, M190 or D380 Astronergy CHSM 6610M(BL)-240 M215, M190 or D380 3 Copyright © 2012 Enphase Energy 08/01/2012 Electrically-Compatible PV Modules Electrically-Compatible PV Modules Manufacturer Name Model Number Enphase Microinverter Astronergy CHSM 6610M(BL)-245 M215, M190 or D380 Astronergy CHSM 6610M(BL)-250 M215, M190 or D380 Astronergy CHSM 6610P-220 M215, M190 or D380 Astronergy CHSM 6610P-225 M215, M190 or D380 Astronergy CHSM 6610P-230 M215, M190 or D380 Astronergy CHSM 6610P-235 M215, M190 or D380 Astronergy CHSM 6610P-240 M215, M190 or D380 Astronergy CHSM 6610P-245 M215, M190 or D380 Astronergy CHSM 6610P-250 M215, M190, or D380 Atersa Grupo Elecnor A-230P M215, M190 or D380 Atersa Grupo Elecnor A-235P M215, M190 or D380 Atersa Grupo Elecnor A-240P M215, M190 or D380 Atersa Grupo Elecnor A-245P M215, M190 or D380 Atersa Grupo Elecnor A-250M M215, M190 or D380 Atersa Grupo Elecnor A-250P M215, M190 or D380 Atersa Grupo Elecnor A-255M M215 Auxin Solar AXN-M6T225 M215, M190 or D380 Auxin Solar AXN-M6T230 M215, M190 or D380 Auxin Solar AXN-M6T235 M215, M190, or D380 Auxin Solar AXN-M6T240 M215, M190 or D380 Auxin Solar AXN-M6T245 M215, M190, or D380 Auxin Solar AXN-P6T210 M215, M190 or D380 Auxin Solar AXN-P6T215 M215, M190 or D380 Auxin Solar AXN-P6T220 M215, M190, or D380 Auxin Solar AXN-P6T225 M215, M190 or D380 Auxin Solar AXN-P6T230 M215, M190 or D380 Auxin
Recommended publications
  • Solar Technical Appendix
    STRUCTURAL TECHNICAL APPENDIX 01/15/2015 for Residential Rooftop Solar Installations Structural Technical Appendix for Residential Rooftop Solar Installations (Appendix to California's Solar Permitting Guidebook's Toolkit Structural Document, based on the 2013 California Residential Code and 2013 California Building Code) STRUCTURAL TECHNICAL APPENDIX 01/15/2015 for Residential Rooftop Solar Installations Table of Contents Introduction 4 Overall Intent 4 Criteria for Expedited Permitting are not Limits for other Systems 4 Background/History 4 Purpose of the Structural Technical Appendix 5 Code Basis 5 California Residential Code (CRC) versus California Building Code (CBC) 5 Design Wind Speeds in CRC versus CBC 5 Organization of the Remainder of this Technical Appendix 6 Part 0. Region and Site Checks 8 Assumptions Regarding Snow and Wind Loads 8 Optional Additional Site Checks in Atypical Regions 9 Part 1. Roof Checks 15 Code Compliant Wood-framed Roof 15 1.A. Visual Review 15 Site Auditor Qualifications 15 Digital Photo Documentation 16 1.A.(1). No Reroof Overlays 16 1.A.(2). No Significant Structural Deterioration or Sagging 17 1.B. Roof Structure Data: 18 1.B.+ Optional Additional Rafter Span Check Criteria 18 Choose By Advantage 19 Horizontal Rafter Span Check 20 Prescriptive Rafter Strengthening Strategies 21 Roof Mean Height 22 Part 2. Solar Array Checks 24 2.A. "Flush-Mounted" Rooftop Solar Arrays 24 2.B. Solar Array Self-Weight 24 2.C. Solar Array Covers No More than Half the Total Roof Area 27 2.D. Solar Support Component Manufacturer's Guidelines 27 2.E. Roof Plan of Module and Anchor Layout 27 2.F.
    [Show full text]
  • Design P2P Energy Trading
    Design a Peer to Peer Energy Trading Model: Can Residents Trade Excess Renewable Solar Energy with Industrial Users? William Jackson, Lara Basyouni, Joseph Kim, Anar Altangerel, Casey Nguyen Microgrid Exchange System After 100%, energy goes into the ground. Excess Renewable Solar Excess Renewable Wasted Solar Energy Energy Solar Energy Area =2503 kWh Area =520 kWh 1 Overview • Context Analysis • Stakeholders • Problem/Need Statement • Confluence Interaction Diagram • Gap Analysis • Concept of Operations • IDEF0 Diagram • Model Simulation • System Requirements • Physical Hierarchy • Model Results • Model Verification Plan • Graphical User Interface • Business Case • System Applications • Conclusion 2 Context Analysis-Cheap Solar • Installed Solar: Price of Solar Energy Trend is projected to drop Opportunity: Lower upfront solar costs goes down to below $50 per mWh in 2024 from $350 per mWh in 2009 . for residential users. Challenge: Technology gap still exists with distribution battery energy storage systems. Those limitations on storage capacity could result in excess solar energy production during peak daytime hours going into the ground. Wasted Solar Energy 1200.00 1000.00 ) 800.00 W n Residential k ( Demand y 600.00 g r e n Residential n “The greatest challenge that solar power faces is energy storage. E 400.00 Solar Generated GMU ENGR Solar arrays can only generate power while the sun is out, so they 200.00 Demand can only be used as a sole source of electricity if they can produce 0.00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
    [Show full text]
  • GREEN AMERICAN GREENAMERICA.ORG in COOPERATION the Big Picture: Green America's Mission Is to Harness Economic Power for a Just and Sustainable Society
    SEPTEMBER/OCTOBER 2013 ISSUE 95 LIVE BETTER. SAVE MORE. INVEST WISELY. GREEN MAKE A DIFFERENCE. AMERICAN INSIDE 4 GMO INSIDE You want to eat organic, buy what you need TARGETS green and Fair Trade, and support renewable CHOBANI energy. But you worry that green can be YOGURT expensive. Is it possible to... REAL GREEN LIVING 6 Go Green FRACKING: THE SITUATION IS GETTING on a Budget? WORSE Page 12 REAL GREEN INVESTING 8 THE FOSSIL-FREE DIVESTMENT MOVEMENT EXPANDS 10 LEAD FOUND IN LIPSTICK SHOWS NEED FOR REFORM DID YOU KNOW? Growing your own salad mix can save you $17.55 for every square foot you plant. Tips for organic 4 ECO ACTIONS on a budget, 10 ACROSS GREEN AMERICA p. 16 23 GREEN BUSINESS NEWS 24 LETTERS & ADVICE Photo by zoryanchik / shutterstock Invest as if our planet depends on it Fossil Fuel Free Balanced Fund You should carefully consider the Funds’ investment objectives, risks, charges, and expenses before investing. To obtain a Prospectus that contains this and other information about the Funds, please visit www.greencentury.com, email [email protected], or call 1-800-93-GREEN. Please read the Prospectus carefully before investing. Stocks will fluctuate in response to factors that may affect a single company, industry, sector, or the market as a whole and may perform worse than the market. Bonds are subject to risks including interest rate, credit, and inflation. The Green Century Funds are distributed by UMB Distribution Services, LLC. 3/13 2 SEPTEMBER/OCTOBER 2013 GREEN AMERICAN GREENAMERICA.ORG IN COOPERATION The Big Picture: Green America's mission is to harness economic power for a just and sustainable society.
    [Show full text]
  • 2015 Annual Report About STR
    2015 Annual Report About STR STR manufactures encapsulants for the photovoltaic solar module industry. Our Photocap® encapsulants are of high quality due to our proprietary technology developed under contract to the predecessor to the U.S. Department of Energy in the late 1970s. Since pioneering this technology, we have the longest track record of field performance for solar encapsulants in the industry. For over 35 years, we have been advancing solar energy as a key renewable, safe and clean electricity source. We strive to be the best at what we do while maintaining the highest ethical standards. For more information about STR, please visit www.strsolar.com. STR-IQ Core Value System SAFETY The safety and well-being of our employees is our highest priority. TENACITY We pursue continuous improvement with persistent determination and view every challenge as an opportunity. RESPONSIBILITY We hold ourselves and each other accountable and strive to be a responsible corporate citizen of the communities in which we operate. INTEGRITY Integrity is at the core of everything we do, every product we make and every service we offer. QUALITY Quality is an integral part of every day and every job. FORWARD-LOOKING STATEMENTS This Annual Report may contain projections or other forward-looking statements regarding future events or the future financial performance of STR Holdings, Inc. We wish to caution you that these statements are only predictions and that the actual events or results may differ materially. We refer you to Forward-Looking Statements in section 7 of the Form 10-K, Management’s Discussion and Analysis of Financial Condition and Results of Operations.
    [Show full text]
  • Solar Skyspace B
    Minnesota Journal of Law, Science & Technology Volume 15 Issue 1 Article 19 2014 Solar Skyspace B Kk K. DuVivier Follow this and additional works at: https://scholarship.law.umn.edu/mjlst Recommended Citation Kk K. DuVivier, Solar Skyspace B, 15 MINN. J.L. SCI. & TECH. 389 (2014). Available at: https://scholarship.law.umn.edu/mjlst/vol15/iss1/19 The Minnesota Journal of Law, Science & Technology is published by the University of Minnesota Libraries Publishing. Solar Skyspace B K.K. DuVivier* I. Introduction ........................................................................... 389 II. The Solar Skyspace Problem ............................................... 391 A. Technology Considerations ..................................... 391 B. Solar Skyspace B ...................................................... 394 III. The Rise and Fall of Solar Access Right Legislation ........ 395 A. Strongest State Solar Access Protections ............... 399 B. State Solar Easement Statutes ............................... 403 C. State Statutes Authorizing Local Regulation of Solar Access.............................................................. 406 D. Local Solar Ordinances .............................................. 408 E. Other Solar Legislation that Has Been Eroded ........ 412 IV. A Case for Stronger Legislative Protections for Solar Skyspace B ...................................................................... 414 A. Common Law Rationales ......................................... 415 1. Ad Coelum Doctrine ..........................................
    [Show full text]
  • Electrically-Compatible PV Modules Updated 12/30/11
    Technical Brief Electrically-Compatible PV Modules Updated 12/30/11 The photovoltaic (PV) modules on this list have been verified for electrical compatibility with Enphase Microinverters over the cell temperature range of -25C to +75C. This document is intended as a means of reference and is not an exhaustive list of compatible modules. For applications outside of this temperature range, the system designer should verify that the module voltage and/or current would not exceed the microinverter model's nameplate ratings under all expected environmental conditions. The module specification sheet contains all of the necessary module information to make this determination. The ASHRAE Handbook (www.ashrae.org) is the recommended source for weather data. Check for updates to this document at http://www.enphase.com/support/downloads. Electrical versus Mechanical Compatibility The modules on this list are not verified for mechanical compatibility with Enphase Microinverters. To ensure mechanical compatibility, be sure to order the correct connector type for both microinverter and PV module from your distributor. CAUTION regarding Mechanical Compatibility of DC Connectors: Be aware that inclusion on this list indicates electrical compatibility, but does not guarantee mechanical compatibility of the PV module connectors. Be sure to order the correct connector type for both microinverter and PV module from your distributor. Enphase Microinverters must be ordered for specific module connector types. Microinverters are manufactured with two types of DC connectors for mating with PV modules. These are MC-4 and Tyco connectors. The polarity of the DC connectors on the microinverter varies with the type of connector: • When your microinverters are built with MC-4 compatible (S12/S22) connectors: The positive DC output of the PV module (+) connects to the microinverter connector labeled negative (-).
    [Show full text]
  • Certain Crystalline Silicon Photovoltaic Products from China and Taiwan
    Certain Crystalline Silicon Photovoltaic Products from China and Taiwan Investigation Nos. 701-TA-511 & 731-TA-1246-1247 (Preliminary) Publication 4454 February 2014 U.S. International Trade Commission Washington, DC 20436 U.S. International Trade Commission COMMISSIONERS Irving A. Williamson, Chairman Shara L. Aranoff Dean A. Pinkert David S. Johanson Meredith M. Broadbent F. Scott Kieff Robert B. Koopman Director of Operations Staff assigned Christopher Cassise, Senior Investigator Andrew David, Industry Analyst Aimee Larsen, Economist David Boyland, Accountant Russell Duncan, Statistician Darlene Smith, Statistical Assistant Rhonda Hughes, Attorney James McClure, Supervisory Investigator Address all communications to Secretary to the Commission United States International Trade Commission Washington, DC 20436 U.S. International Trade Commission Washington, DC 20436 www.usitc.gov Certain Crystalline Silicon Photovoltaic Products from China and Taiwan Investigation Nos. 701-TA-511 & 731-TA-1246-1247 (Preliminary) Publication 4454 February 2014 CONTENTS Page Determinations ............................................................................................................................... 1 Views of the Commission ............................................................................................................... 3 Part I: Introduction ................................................................................................................ I‐1 Background ...............................................................................................................................
    [Show full text]
  • The Feasibility of a Solar Feed-In Tariff Program for the State of Oregon: a Case Study of Eugene Water & Electric Board
    THE FEASIBILITY OF A SOLAR FEED-IN TARIFF PROGRAM FOR THE STATE OF OREGON: A CASE STUDY OF EUGENE WATER & ELECTRIC BOARD By BAOFENG DONG TERMINAL PROJECT Presented to the Department of Planning, Public Policy & Management, School of Architecture and Allied Arts, of the University of Oregon in partial fulfillment of the requirements for the degree of Master of Community and Regional Planning JUNE 2012 Committee: Dr. Robert F. Young (chair), Sibyl Geiselman “The Feasibility of a Solar Feed-in tariff Program for the State of Oregon: A Case Study of Eugene Water & Electric Board,” a terminal project prepared by Baofeng Dong in partial fulfillment of the requirements for the Master of Community and Regional Planning degree in the Department of Planning, Public Policy and Management. This project has been approved and accepted by: ____________________________________________________________ Dr. Robert F. Young, Chair of the Examining Committee Assistant Professor, Department of Planning, Public Policy and Management ________________________________________ Date Committee in Charge: Dr. Robert F. Young, Chair Sibyl Geiselman © 2012 Baofeng Dong i Acknowledgements I am very grateful for the guidance and great input from Professor Robert F. Young, assistant professor at the University of Oregon. I am fortunate enough to have had many constructive and inspiring conversations with him on sustainability, human civilization, and ecology. These conversations have helped me to frame and formulate my research on solar energy deployment. I would also like to thank Sibyl Geiselman and Colleen Wedin from EWEB; their input and professional experience have helped my project tremendously. Thanks also to Ray Neff from Oregonians for Renewable Energy Policy, whose previous terminal project on solar feed-in tariff inspired me to conduct this research and who also reviewed chapters of my project and helped refine my project.
    [Show full text]
  • Open Hakunthesis.Pdf
    THE PENNSYLVANIA STATE UNIVERSITY SCHREYER HONORS COLLEGE DEPARTMENT OF ENERGY AND MINERAL ENGINEERING ELECTRIFICATION OF FARMING STRUCTURES THROUGH ADAPTABLE SOLAR POWER SYSTEMS IN THE NORTHEAST UNITED STATES: AN ANALYSIS ON DECISION MAKING AND SOLAR UTILITY JENNAFER S. HAKUN SPRING 2018 A thesis submitted in partial fulfillment of the requirements for a baccalaureate degree in Energy Engineering with honors in Energy Engineering Reviewed and approved* by the following: Jeffrey Brownson Professor of Energy and Mineral Engineering Thesis Supervisor Sarma Pisupati Professor of Energy and Mineral Engineering Honors Adviser * Signatures are on file in the Schreyer Honors College. i ABSTRACT This study was conducted to determine an optimal design for a small-scale adaptable power system that could be used to provide energy for electricity loads in sustainable farming locations in the Northeast United States. This research project analyzed two locales in Pennsylvania. The first, was the Penn State Student Farm located in State College, PA representing a rural sustainable farm. The second, was the Mill Creek Urban Farm in Philadelphia, PA representing an urban sustainable farm. The Mill Creek Urban Farm had a higher price of electricity and the ability to easily connect to an electric grid while the Penn State Student Farm had a lower price of electricity and did not have the ability to connect to an electric grid. A stakeholder interview was conducted for each locale and a preference and risk aversion study was completed to determine the optimal design for both locales. Additionally, an electricity load analysis was done to establish the total amount of electricity needed at each locale.
    [Show full text]
  • Solar Poweroptimized Cart
    Solar Power­Optimized Cart (SPOC) Senior Design Project Documentation Due: December 2, 2013 Group #28 Members: Jacob Bitterman Cameron Boozarjomehri William Ellett Table of contents 1. Executive Summary 2. Project Description 2.1. Motivation 2.2. Goals 2.3. Objectives 2.4. Project Requirements and Specifications 2.5. Limitations 3. Research related to Project Definition 3.1. Existing Similar Projects and Products 3.2. Relevant Technologies 3.3. Strategic Components 3.3.1. Cart 3.3.2. Microcontroller 3.3.3. User Interface 3.3.4. Battery 3.3.5. Solar Array 3.4. Possible Architectures and Related Diagrams 3.4.1. Solar Array Architecture 3.4.2. Motor, Battery, Micro Controller Integration 3.4.3. Electrical Integration of Battery, Cart, Panels, and UI 3.4.4. User Interface Layout 4. Project Hardware and Software Design Details 4.1. Initial Design Architecture and Related Diagrams 4.2. Solar Array Subsystem 4.3. Cart Subsystem 4.4. Power Subsystem 4.5. User Interface Subsystem 5. Design Summary of Hardware and Software 5.1. Solar Cell Charge System 5.2. Battery Motor Integration 5.3. Sensor Integration 5.4. User Interface 5.4.1. Hardware components 5.4.2. Software I/O 5.5. Vehicle Mode Modeling 6. Project Prototype Construction and Coding 6.1. Part Acquisition and Bill of Materials 6.2. PCB Vendor and Assembly 6.3. Final Coding Plan 6.3.1. Eco System 6.3.2. Performance System 6.3.3. User Interface 6.3.4. Vehicle Monitoring Integration 7. Project Prototype Testing 7.1. Hardware Test Environment 7.2.
    [Show full text]
  • Research.Pdf (644.2Kb)
    Off Grid Solar System for Profitable Energy Source in Missouri A Thesis Presented to the Faculty of the Graduate School University of Missouri-Columbia In Partial Fulfillment of the Requirements for the Degree Master of Science by NAHOM GHIRMATZION Dr. Thomas G. Engel, Thesis Supervisor MAY 2018 The undersigned, appointed by the Dean of the Graduate School, have examined the Thesis entitled SOLAR ENERGY FOR PROFITABLE ENERGY SOURCE IN MISSOURI Presented by Nahom Ghirmatzion A candidate for the degree of Master of Science And hereby certify that in their opinion it is worthy of acceptance. Professor Thomas G. Engel Professor Mark A Prelas Professor Robert V. Tompson JR. ACKNOWLEDGEMENTS This research was mainly on system design, that requires a lot of ideas, behind the mathematics part, that needs to put into consideration, and Dr. Engel played a major role on this research, and with out his guidance, I would not get to this end. And as this research also discusses the benefit of solar system in the future, his past experience in the area of solar systems, encouraged me to search more and understand that solar system is becoming more promising source of renewable energy. So, I would like to thank Dr. Engel for being a great advisor and for his enthusiasm in helping me to finish my research. ii TABLE OF CONTENTS ACKNOWLEDGEMENTS ...........................................................................................................ii LIST OF FIGURES.........................................................................................................................v
    [Show full text]
  • Long Island Solar Roadmap
    LONG ISLAND SOLARROADMAP Advancing Low-Impact Solar in Nassau & Suffolk Counties Acknowledgments The Nature Conservancy and Defenders of Wildlife wish to extend their sincere appreciation to all those who contributed to the Long Island Solar Roadmap. Members of the steering committee and consortium provided input throughout the past three years on the framework for the project, the research conducted to identify the challenges and opportunities for low-impact solar, and the strategies and actions that emerged to address them. Their input represents their personal opinions and does not necessarily reflect the official policies or positions of their employer or organization. The Nature Conservancy and Defenders of Wildlife take sole responsibility for the final content of this report. STEERING COMMITTEE Ryan Madden, Long Island Progressive Coalition Robert Boerner, PSEG Long Island Andrew Manitt, Sustainability Institute at Molloy College Michael J. Deering, Long Island Power Authority Ryan McTiernan, City of Long Beach Jossi Fritz-Mauer, PSEG Long Island Nicholas Palumbo, Suffolk County Community College Timothy Lederer, Long Island Power Authority George Povall, All Our Energy Tara McDermott, EmPower Solar & Long Island Gordian Raacke, Renewable Energy Long Island Solar & Storage Alliance Kyle Rabin, Long Island Regional Planning Council Sarah Oral, Cameron Engineering & Clean Energy August Ruckdeschel, Suffolk County Communities program lead for Long Island Kimberly Shaw, Town of East Hampton David G. Schieren, EmPower Solar & New York Lauren Steinberg, Town of East Hampton Solar Energy Industries Association LEADERSHIP TEAM Tara Schneider-Moran, Town of Hempstead Aimee Delach, Defenders of Wildlife CONSORTIUM MEMBERS Karen Leu, The Nature Conservancy Rachel Brinn, Town of North Hempstead Stephen Lloyd, The Nature Conservancy Lisa Broughton, Suffolk County Catherine Morris, Consensus Building Institute Robert Carpenter, Long Island Farm Bureau Jessica Price, The Nature Conservancy Sammy Chu, Edgewise Energy & U.S.
    [Show full text]