Uhsn Hydraulic Cylinders
Total Page:16
File Type:pdf, Size:1020Kb
HYDRAULIC CYLINDER S Contact : Istanbul Deri OSB. Karadeniz Cad. UHSN 13-2 Parsel No : 11 Orhanlı/TUZLA/ISTANBUL/TURKEY Nominal Pressure 250 Bar (25MPa) Phone : (0216) 394 17 36-37 Fax :(0216) 394 22 92 Mail : [email protected] ISO 6022 Web: www.uzunhidrolik.com HYDRAULIC CYLINDERS Technical Data The installation dimensions and types of mounting of the cylinders comply with the standarts DIN 24333 and ISO 6022. Mounting Types : 6 Piston : Ø 40 – 200 mm Piston Rod : Ø 25 – 140 mm Stroke : max 3000 mm (Special stroke length deviating from standard to max. 9000 mm available on request at any time, but depends on the piston Ø, piston rod Ø and the mounting position) Nominal Pressure : 250 bar Test Pressure : 375 bar The specified operating pressures apply to applications with shock-free operation with regard to excess pressure and/ or external loads. Hydraulic Fluid : DIN 51524 HL, HLP Polyol-Ester : HFD-U Hydraulic Fluid Temperature Range: HL, HLP : (-40°C) – (+120°C) HFD-U : (-40°C) – (+120°C) Fluid temperature range : (-40°C) – (+120°C) Viscosity range: 20 – 380 mm²/s ( can be higher by lower temperature) Paint: Hydraulic cylinders are primered with a coating of min. 40 µm + 40 µm topcoat RAL 5010. Paint colors may vary according to demand. Other colors upon request. The paint and primer coat coding order information will be given as additional information. Notice : The sketches can vary from real application . Please contact us for any related question UZUN HIDROLIK SAN ve TIC A.S. 2 ENCODING ORDER Examples of Coding : UHSN-S-S-MP5-100/56-500-P-0/3-C-3-G-A-TF-W, Paint: RAL 5010 Remarks : 1) In special cylinders (UHSN-S-X- ...) size may vary. 2) Unless otherwise stated 0/0 valve connections, ventilation is 3/3. 3) Max. available stroke length page 4 and admissible stroke length observe page 15 and 16 UZUN HIDROLIK SAN ve TIC A.S. 3 Note : Theoretical force ( efficiency not taken into account. ) Tolerances according to ISO 6020-1 Installation WC XC² XO² XS¹ ² XV² ZP² Dimensions Stroke Tolerances Mounting Types MF3 MP3 MP5 MS2 MT4 MF4 Stroke Tolerance Tolerance Tolerance Tolerance Tolerance Tolerance Tolerance ≤ 1250 ± 2 ± 1,5 ± 1,5 ± 2 ± 2 ± 1,5 2 1250 - 3149 ± 4 ± 3 ± 3 ± 4 ± 4 ± 3 5 3150 - 8000 ± 8 ± 5 ± 5 ± 8 ± 8 ± 5 8 ¹ : Stroke length included ² : No Standardized UZUN HIDROLIK SAN ve TIC A.S. 4 MOUNTING TYPE OVERVIEW CYLINDER COMMON PARTS UZUN HIDROLIK SAN ve TIC A.S. 5 BASIC VERSION MOUNTING TYPE : ALL UHSN-S-S AL MM EE EE KK A NV ØD ØDA ØD4 PJ WA X1 Y ZB Ø Ø 7) 7) 25 19 40 ³ M20 x 1,5 28 88 50 34 G1/2 M22 x 1,5 120 18 41 83 282 28 22 32 27 50 M27 x 2 36 102 65 34 G1/2 M22 x 1,5 120 18 48,5 98 305 36 30 40 32 63 M33 x 2 45 120 78 42 G3/4 M27 x 2 133 21 56,5 112 348 45 36 50 41 80 M42 x 2 56 145 100 42 G3/4 M27 x 2 155 24 69,5 120 395 56 46 63 50 100 M48 x 2 63 170 125 47 G1 M33 x 2 171 27 82 134 442 70 60 80 65 125 M64 x 3 85 206 150 47 G1 M33 x 2 205 31 100,5 153 520 90 75 90 75 140 M72 x 3 90 226 170 58 G11/4 M42 x 2 219 31 109,5 166 580 100 85 100 85 160 M80 x 3 95 265 190 58 G11/4 M42 x 2 235 35 129,5 185 617 110 95 110 95 180 M90 x 3 105 292 220 58 G11/4 M42 x 2 264 40 143,5 194 690 125 110 125 110 200 M100 x 3 112 306 245 58 G11/4 M42 x 2 278 40 150,5 220 756 140 120 * Ø AL : Piston Ø * Ø MM : Piston rod Ø * Bleeding : With view to the piston rod, the position is offset by 90° in relation to the line connection (clockwise) * ØD4 max. 1 mm deep ³ : Piston Ø not standardized * S : Stroke * For flange connection , see separate table on pages 12 and 13 UZUN HIDROLIK SAN ve TIC A.S. 6 MOUNTING TYPE : MP3 – MP5 MP3 ; MP5 ; Dimensions MP3 and MP5 AL MM EE EE CD CX EW EX KK A NV ØD ØDA ØD4 WA X1 PJ Y EP L LT L1 MR MS M1 XC X0 Ø Ø 7) 7) H9 H7 h12 h12 25 19 40 ³ M20 x 1,5 28 88 50 34 G1/2 M22 x 1,518 41 120 83 25 25 22 25 25 53 53 8 32 32 32 282 282 28 22 32 27 50 M27 x 2 36 102 70 34 G1/2 M22 x 1,518 48,5 120 98 32 32 27 32 32 61 61 8 40 40 40 305 305 36 30 40 32 63 M33 x 2 45 120 78 42 G3/4 M27 x 221 56,5 133 112 40 40 32 40 40 74 74 8 50 50 50 348 348 45 36 50 41 80 M42 x 2 56 145 100 42 G3/4 M27 x 224 69,5 155 120 50 50 40 50 50 90 90 10 63 63 63 395 395 56 46 63 50 100 M48 x 2 63 170 125 47 G1 M33 x 227 82 171 134 63 63 52 63 63 102 102 12 71 71 71 442 442 70 60 80 65 125 M64 x 3 85 206 150 47 G1 M33 x 231 101 205 153 80 80 66 80 80 124 124 16 90 90 90 520 520 90 75 90 75 140 M72 x 3 90 226 170 58 G11/4 M42 x 231 110 219 166 90 90 72 90 90 149 149 16 100 100 100 580 580 100 85 100 85 160 M80 x 3 95 265 190 58 G11/4 M42 x 235 130 235 185 100 100 84 100 100 150 150 16 112 112 112 617 617 110 95 110 95 180 M90 x 3 105 292 220 58 G11/4 M42 x 240 144 264 194 110 110 88 110 110 180 180 20 129 129 129 690 690 125 110 125 110 200 M100 x 3 112 306 245 58 G11/4 M42 x 240 151 278 220 125 125 102 125 125 206 206 20 145 145 145 756 756 140 120 *AL : PistonØ *MM : Piston rod * S : Stroke * ³ : Piston Ø not standardized * 7) For flange connection, see separate table on pages 12 and 13 *D4 max. 1 mm deep * Bleeding : With view to the piston rod, the poisiton is offset by 90° in relation to the line connection (clockwise) UZUN HIDROLIK SAN ve TIC A.S. 7 MOUNTING TYPE : MF3 UHSN-T-S-MF3 Dimensions MF3 AL MM EE EE ØRD ØFB FC UC KK A NV ØD ØDA ØD4 Y PJ X1 NF PK VD WA WC ZB ZM & Ø Ø 7) 7) f8 H13 js13 Ø-1 25 19 40 ³ M20 x 1,5 28 88 50 34 G1/2 M22 x 1,583 120 41 52 11 115 25 120 138 418 22 230 286 45 28 22 32 27 50 M27 x 2 36 102 70 34 G1/2 M22 x 1,598 120 48,5 63 13,5 13225 120155 4 18 22 244 316 45 36 30 40 32 63 M33 x 245 120 78 42 G3/4 M27 x 2 112 133 56,5 75 13,5 150 28 133 175 4 21 25 274 357 45 45 36 50 41 80 M42 x 2 56 145 100 42 G3/4 M27 x 2120 155 69,5 90 17,5 180 32 155 210 4 24 28 305 395 45 56 46 63 50 100 M48 x 2 63 170 125 47 G1 M33 x 2134 17182 110 22 212 36 171 250 5 27 32 340 439 45 70 60 80 65 125 M64 x 3 85 206 150 47 G1 M33 x 2153 205 100,5 132 22 250 40 205 290 5 31 36 396 511 45 90 75 90 75 140 M72 x 3 90 226 170 58 G11/4 M42 x 2166 219 109,5 145 26 285 40 219 330 5 31 36 430 551 45 100 85 100 85 160 M80 x 3 95 265 190 58 G11/4 M42 x 2185 235 129,5 160 26 315 45 235 360 5 35 40 467 605 45 110 95 110 95 180 M90 x 3 105 292 220 58 G11/4M42 x 2 194 264 143,5 185 33 355 50 264 410 5 40 45 510 652 45 125 110 125 110 200 M100 x 3 112 306 245 58 G11/4 M42 x 2220 278 150,5 200 33 385 56 278 440 5 40 45 550 718 45 140 120 *AL : Piston Ø *MM : Piston rod Ø ³ : Piston Ø not standardized * For main dimensions, see page 6 * S : Stroke * 7) For flange connection, see separate table on pages 12 and 13 * Bleeding : With view to the piston rod, the poisiton is offset by 90° in relation to the line connection (clockwise) UZUN HIDROLIK SAN ve TIC A.S. 8 MOUNTING TYPE : MF4 Dimensions MF4 AL MM EE EE ØBA ØFB FC NF UC KK A NV ØD ØDA ØD4 Y PJ WA X1 ZB VA ZP & Ø Ø 7) 7) H8 H13 js13 js13 Ø-1 25 19 40 ³ M20 x 1,5 28 88 50 34 G1/2 M22 x 1,583 120 18 41 282 52 11 115 25138 5 250 45 28 22 32 27 50 M27 x 2 36 102 70 34 G1/2 M22 x 1,598 120 18 48,5 305 63 13,5 132 25 155 4 265 45 36 30 40 32 63 M33 x 2 45 120 78 42 G3/4 M27 x 2112 133 21 56,5 348 75 13,5 150 28 175 4 298 45 45 36 50 41 80 M42 x 2 56 145 100 42 G3/4 M27 x 2120 155 24 69,5 395 90 17,5 180 32 210 5 332 45 56 46 63 50 100 M48 x 2 63 170 125 47 G1 M33 x 2134 171 27 82 442 110 22 212 36 250 5 371 45 70 60 80 65 125 M64 x 3 85 206 150 47 G1 M33 x 2153 205 31 100,5 520 132 22 250 40 290 6 430 45 90 75 90 75 140 M72 x 3 90 226 170 58 G11/4 M42 x 2166 219 31 109,5 580 145 26 280 40 325 5 465 45 100 85 100 85 160 M80 x 3 95 265 190 58 G11/4 M42 x 2185 235 35 129,5 617 160 26 315 45 360 7 505 45 110 95 110 95 180 M90 x 3 105 292 220 58 G11/4 M42 x 2194 264 40 143,5 690 185 33 350 50 405 10 550 45 125 110 125 110 200 M100 x 3 112 306 245 58 G11/4 M42 x 2220 278 40 150,5 756 200 33 385 56 440 10 596 45 140 120 *AL : PistonØ *MM : Piston rodØ *S : Stroke * ³ : Piston Ø not standardized * 7) For flange connection, see separate table on pages 12 and 13 *Bleeding : With view toto the piston rod, the positon is offset by 90° in relation to the line connection (clockwise) UZUN HIDROLIK SAN ve TIC A.S.