Reference: Mesh Micron Conversion Chart Reference: Principles Of
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Dial Caliperscalipers at the Conclusion of This Presentation, You Will Be Able To…
Forging new generations of engineers DialDial CalipersCalipers At the conclusion of this presentation, you will be able to… identify four types of measurements that dial calipers can perform. identify the different parts of a dial caliper. accurately read an inch dial caliper. DialDial CalipersCalipers GeneralGeneral InformationInformation DialDial CalipersCalipers are arguably the most common and versatile of all the precision measuring tools. Engineers, technicians, scientists and machinists use precision measurement tools every day for: • analysis • reverse engineering • inspection • manufacturing • engineering design DialDial CalipersCalipers FourFour TypesTypes ofof MeasurementsMeasurements Dial calipers are used to perform four common measurements on parts… 1. Outside Diameter/Object Thickness 2. Inside Diameter/Space Width 3. Step Distance 4. Hole Depth OutsideOutside MeasuringMeasuring FacesFaces These are the faces between which outside length or diameter is measured. InsideInside MeasuringMeasuring FacesFaces These are the faces between which inside diameter or space width (i.e., slot width) is measured. StepStep MeasuringMeasuring FacesFaces These are the faces between which stepped parallel surface distance can be measured. DepthDepth MeasuringMeasuring FacesFaces These are the faces between which the depth of a hole can be measured. Note: Work piece is shown in section. Dial Caliper shortened for graphic purposes. DialDial CalipersCalipers NomenclatureNomenclature A standard inchinch dialdial calipercaliper will measure slightly more than 6 inches. The bladeblade scalescale shows each inch divided into 10 increments. Each increment equals one hundred thousandths (0.100”). Note: Some dial calipers have blade scales that are located above or below the rack. BladeBlade The bladeblade is the immovable portion of the dial caliper. SliderSlider The sliderslider moves along the blade and is used to adjust the distance between the measuring surfaces. -
A Guidebook to Particle Size Analysis Table of Contents
A GUIDEBOOK TO PARTICLE SIZE ANALYSIS TABLE OF CONTENTS 1 Why is particle size important? Which size to measure 3 Understanding and interpreting particle size distribution calculations Central values: mean, median, mode Distribution widths Technique dependence Laser diffraction Dynamic light scattering Image analysis 8 Particle size result interpretation: number vs. volume distributions Transforming results 10 Setting particle size specifications Distribution basis Distribution points Including a mean value X vs.Y axis Testing reproducibility Including the error Setting specifications for various analysis techniques Particle Size Analysis Techniques 15 LA-960 laser diffraction technique The importance of optical model Building a state of the art laser diffraction analyzer 18 LA-350 laser diffraction technique Compact optical bench and circulation pump in one system 19 ViewSizer 3000 nanotracking analysis A Breakthrough in nanoparticle tracking analysis 20 SZ-100 dynamic light scattering technique Calculating particle size Zeta Potential Molecular weight 25 PSA300 image analysis techniques Static image analysis Dynamic image analysis 27 Dynamic range of the HORIBA particle characterization systems 27 Selecting a particle size analyzer When to choose laser diffraction When to choose dynamic light scattering When to choose image analysis 31 References Why is particle size important? Particle size influences many properties of particulate materials and is a valuable indicator of quality and performance. This is true for powders, Particle size is critical within suspensions, emulsions, and aerosols. The size and shape of powders influences a vast number of industries. flow and compaction properties. Larger, more spherical particles will typically flow For example, it determines: more easily than smaller or high aspect ratio particles. -
Units and Conversions
Units and Conversions This unit of the Metrology Fundamentals series was developed by the Mitutoyo Institute of Metrology, the educational department within Mitutoyo America Corporation. The Mitutoyo Institute of Metrology provides educational courses and free on-demand resources across a wide variety of measurement related topics including basic inspection techniques, principles of dimensional metrology, calibration methods, and GD&T. For more information on the educational opportunities available from Mitutoyo America Corporation, visit us at www.mitutoyo.com/education. This technical bulletin addresses an important aspect of the language of measurement – the units used when reporting or discussing measured values. The dimensioning and tolerancing practices used on engineering drawings and related product specifications use either decimal inch (in) or millimeter (mm) units. Dimensional measurements are therefore usually reported in either of these units, but there are a number of variations and conversions that must be understood. Measurement accuracy, equipment specifications, measured deviations, and errors are typically very small numbers, and therefore a more practical spoken language of units has grown out of manufacturing and precision measurement practice. Metric System In the metric system (SI or International System of Units), the fundamental unit of length is the meter (m). Engineering drawings and measurement systems use the millimeter (mm), which is one thousandths of a meter (1 mm = 0.001 m). In general practice, however, the common spoken unit is the “micron”, which is slang for the micrometer (m), one millionth of a meter (1 m = 0.001 mm = 0.000001 m). In more rare cases, the nanometer (nm) is used, which is one billionth of a meter. -
Nanomaterials How to Analyze Nanomaterials Using Powder Diffraction and the Powder Diffraction File™
Nanomaterials How to analyze nanomaterials using powder diffraction and the Powder Diffraction File™ Cerium Oxide CeO2 PDF 00-064-0737 7,000 6,000 5,000 4,000 Intensity 3,000 2,000 1,000 20 30 40 50 60 70 80 90 100 110 120 Nanomaterials Table of Contents Materials with new and incredible properties are being produced around the world by controlled design at the atomic and molecular level. These nanomaterials are typically About the Powder Diffraction File ......... 1 produced in the 1-100 nm size scale, and with this small size they have tremendous About Powder Diffraction ...................... 1 surface area and corresponding relative percent levels of surface atoms. Both the size and available (reactive) surface area can contribute to unique physical properties, Analysis Tools for Nanomaterials .......... 1 such as optical transparency, high dissolution rate, and enormous strength. Crystallite Size and Particle Size ������������ 2 In this Technical Bulletin, we are primarily focused on the use of structural simulations XRPD Pattern for NaCI – An Example .... 2 in order to examine the approximate crystallite size and molecular orientation in nanomaterials. The emphasis will be on X-ray analysis of nanomaterials. However, Total Pattern Analysis and the �������������� 3 Powder Diffraction File electrons and neutrons can have similar wavelengths as X-rays, and all of the X-ray methods described have analogs with neutron and electron diffraction. The use of Pair Distribution Function Analysis ........ 3 simulations allows one to study any nanomaterials that have a known atomic and Amorphous Materials ............................ 4 molecular structure or one can use a characteristic and reproducible experimental diffraction pattern. -
Chapter 5 Dimensional Analysis and Similarity
Chapter 5 Dimensional Analysis and Similarity Motivation. In this chapter we discuss the planning, presentation, and interpretation of experimental data. We shall try to convince you that such data are best presented in dimensionless form. Experiments which might result in tables of output, or even mul- tiple volumes of tables, might be reduced to a single set of curves—or even a single curve—when suitably nondimensionalized. The technique for doing this is dimensional analysis. Chapter 3 presented gross control-volume balances of mass, momentum, and en- ergy which led to estimates of global parameters: mass flow, force, torque, total heat transfer. Chapter 4 presented infinitesimal balances which led to the basic partial dif- ferential equations of fluid flow and some particular solutions. These two chapters cov- ered analytical techniques, which are limited to fairly simple geometries and well- defined boundary conditions. Probably one-third of fluid-flow problems can be attacked in this analytical or theoretical manner. The other two-thirds of all fluid problems are too complex, both geometrically and physically, to be solved analytically. They must be tested by experiment. Their behav- ior is reported as experimental data. Such data are much more useful if they are ex- pressed in compact, economic form. Graphs are especially useful, since tabulated data cannot be absorbed, nor can the trends and rates of change be observed, by most en- gineering eyes. These are the motivations for dimensional analysis. The technique is traditional in fluid mechanics and is useful in all engineering and physical sciences, with notable uses also seen in the biological and social sciences. -
The Not So Short Introduction to Latex2ε
The Not So Short Introduction to LATEX 2ε Or LATEX 2ε in 139 minutes by Tobias Oetiker Hubert Partl, Irene Hyna and Elisabeth Schlegl Version 4.20, May 31, 2006 ii Copyright ©1995-2005 Tobias Oetiker and Contributers. All rights reserved. This document is free; you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation; either version 2 of the License, or (at your option) any later version. This document is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details. You should have received a copy of the GNU General Public License along with this document; if not, write to the Free Software Foundation, Inc., 675 Mass Ave, Cambridge, MA 02139, USA. Thank you! Much of the material used in this introduction comes from an Austrian introduction to LATEX 2.09 written in German by: Hubert Partl <[email protected]> Zentraler Informatikdienst der Universität für Bodenkultur Wien Irene Hyna <[email protected]> Bundesministerium für Wissenschaft und Forschung Wien Elisabeth Schlegl <noemail> in Graz If you are interested in the German document, you can find a version updated for LATEX 2ε by Jörg Knappen at CTAN:/tex-archive/info/lshort/german iv Thank you! The following individuals helped with corrections, suggestions and material to improve this paper. They put in a big effort to help me get this document into its present shape. -
A Comparative Study of Particle Size Distribution of Graphene Nanosheets Synthesized by an Ultrasound-Assisted Method
nanomaterials Article A Comparative Study of Particle Size Distribution of Graphene Nanosheets Synthesized by an Ultrasound-Assisted Method Juan Amaro-Gahete 1,† , Almudena Benítez 2,† , Rocío Otero 2, Dolores Esquivel 1 , César Jiménez-Sanchidrián 1, Julián Morales 2, Álvaro Caballero 2,* and Francisco J. Romero-Salguero 1,* 1 Departamento de Química Orgánica, Instituto Universitario de Investigación en Química Fina y Nanoquímica, Facultad de Ciencias, Universidad de Córdoba, 14071 Córdoba, Spain; [email protected] (J.A.-G.); [email protected] (D.E.); [email protected] (C.J.-S.) 2 Departamento de Química Inorgánica e Ingeniería Química, Instituto Universitario de Investigación en Química Fina y Nanoquímica, Facultad de Ciencias, Universidad de Córdoba, 14071 Córdoba, Spain; [email protected] (A.B.); [email protected] (R.O.); [email protected] (J.M.) * Correspondence: [email protected] (A.C.); [email protected] (F.J.R.-S.); Tel.: +34-957-218620 (A.C.) † These authors contributed equally to this work. Received: 24 December 2018; Accepted: 23 January 2019; Published: 26 January 2019 Abstract: Graphene-based materials are highly interesting in virtue of their excellent chemical, physical and mechanical properties that make them extremely useful as privileged materials in different industrial applications. Sonochemical methods allow the production of low-defect graphene materials, which are preferred for certain uses. Graphene nanosheets (GNS) have been prepared by exfoliation of a commercial micrographite (MG) using an ultrasound probe. Both materials were characterized by common techniques such as X-ray diffraction (XRD), Transmission Electronic Microscopy (TEM), Raman spectroscopy and X-ray photoelectron spectroscopy (XPS). All of them revealed the formation of exfoliated graphene nanosheets with similar surface characteristics to the pristine graphite but with a decreased crystallite size and number of layers. -
North Montco Technical Career Center in Partnership with Hunter
ModernModern AutomotiveAutomotive TechnologyTechnology ChapterChapter 66 AutomotiveAutomotive MeasurementMeasurement andand MathMath ChapterChapter 66 AutomotiveAutomotive MeasurementMeasurement andand MathMath z Describe standard and metric measuring systems z Identify basic measuring tools z Describe how to use basic measuring tools z List safety rules for measuring tools z Summarize basic math facts ChapterChapter 66 AutomotiveAutomotive MeasurementMeasurement andand MathMath 1. A TORQUETORQUE WRENCHWRENCH is used to apply a specific amount of turning force to a fastener. 2. A VACUUMVACUUM GAUGEGAUGE is commonly used to measure negative pressure or suction. TorqueTorque WrenchWrench TheoryTheory One foot-pound equals one pound of pull on a one-foot-long lever arm FlexFlex BarBar TorqueTorque WrenchWrench Uses a bending metal beam to make the pointer read torque on the scale DialDial IndicatorIndicator TorqueTorque WrenchWrench Very accurate type of torque wrench RatchetingRatcheting TorqueTorque WrenchWrench Torque value is set by turning the handle– fastener is tightened until it clicks VacuumVacuum TestTest Connect a vacuum gauge to the inlet - the negative pressure side of the pump ChapterChapter 66 AutomotiveAutomotive MeasurementMeasurement andand MathMath 3. A MICROMETERMICROMETER can easily measure to one ten-thousandth of an inch. 4. A FEELERFEELER GAUGEGAUGE is used to measure small clearances or gaps between parts. ChapterChapter 66 AutomotiveAutomotive MeasurementMeasurement andand MathMath Anvil Measuring Faces Barrel Spindle Thimble Frame PartsParts ofof aa MicrometerMicrometer ChapterChapter 66 AutomotiveAutomotive MeasurementMeasurement andand MathMath Each Blade of a Feeler Gauge is in .001 Increments ChapterChapter 66 AutomotiveAutomotive MeasurementMeasurement andand MathMath 5. A DIALDIAL INDICATORINDICATOR is used to measure part movement in thousandths of an inch. 6. The CONVENTIONALCONVENTIONAL MEASURINGMEASURING SYSTEMSYSTEM originated from sizes taken from the parts of the human body. -
Guide for the Use of the International System of Units (SI)
Guide for the Use of the International System of Units (SI) m kg s cd SI mol K A NIST Special Publication 811 2008 Edition Ambler Thompson and Barry N. Taylor NIST Special Publication 811 2008 Edition Guide for the Use of the International System of Units (SI) Ambler Thompson Technology Services and Barry N. Taylor Physics Laboratory National Institute of Standards and Technology Gaithersburg, MD 20899 (Supersedes NIST Special Publication 811, 1995 Edition, April 1995) March 2008 U.S. Department of Commerce Carlos M. Gutierrez, Secretary National Institute of Standards and Technology James M. Turner, Acting Director National Institute of Standards and Technology Special Publication 811, 2008 Edition (Supersedes NIST Special Publication 811, April 1995 Edition) Natl. Inst. Stand. Technol. Spec. Publ. 811, 2008 Ed., 85 pages (March 2008; 2nd printing November 2008) CODEN: NSPUE3 Note on 2nd printing: This 2nd printing dated November 2008 of NIST SP811 corrects a number of minor typographical errors present in the 1st printing dated March 2008. Guide for the Use of the International System of Units (SI) Preface The International System of Units, universally abbreviated SI (from the French Le Système International d’Unités), is the modern metric system of measurement. Long the dominant measurement system used in science, the SI is becoming the dominant measurement system used in international commerce. The Omnibus Trade and Competitiveness Act of August 1988 [Public Law (PL) 100-418] changed the name of the National Bureau of Standards (NBS) to the National Institute of Standards and Technology (NIST) and gave to NIST the added task of helping U.S. -
How Are Units of Measurement Related to One Another?
UNIT 1 Measurement How are Units of Measurement Related to One Another? I often say that when you can measure what you are speaking about, and express it in numbers, you know something about it; but when you cannot express it in numbers, your knowledge is of a meager and unsatisfactory kind... Lord Kelvin (1824-1907), developer of the absolute scale of temperature measurement Engage: Is Your Locker Big Enough for Your Lunch and Your Galoshes? A. Construct a list of ten units of measurement. Explain the numeric relationship among any three of the ten units you have listed. Before Studying this Unit After Studying this Unit Unit 1 Page 1 Copyright © 2012 Montana Partners This project was largely funded by an ESEA, Title II Part B Mathematics and Science Partnership grant through the Montana Office of Public Instruction. High School Chemistry: An Inquiry Approach 1. Use the measuring instrument provided to you by your teacher to measure your locker (or other rectangular three-dimensional object, if assigned) in meters. Table 1: Locker Measurements Measurement (in meters) Uncertainty in Measurement (in meters) Width Height Depth (optional) Area of Locker Door or Volume of Locker Show Your Work! Pool class data as instructed by your teacher. Table 2: Class Data Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Width Height Depth Area of Locker Door or Volume of Locker Unit 1 Page 2 Copyright © 2012 Montana Partners This project was largely funded by an ESEA, Title II Part B Mathematics and Science Partnership grant through the Montana Office of Public Instruction. -
Download (14Mb)
A Thesis Submitted for the Degree of PhD at the University of Warwick Permanent WRAP URL: http://wrap.warwick.ac.uk/125819 Copyright and reuse: This thesis is made available online and is protected by original copyright. Please scroll down to view the document itself. Please refer to the repository record for this item for information to help you to cite it. Our policy information is available from the repository home page. For more information, please contact the WRAP Team at: [email protected] warwick.ac.uk/lib-publications Anisotropic Colloids: from Synthesis to Transport Phenomena by Brooke W. Longbottom Thesis Submitted to the University of Warwick for the degree of Doctor of Philosophy Department of Chemistry December 2018 Contents List of Tables v List of Figures vi Acknowledgments ix Declarations x Publications List xi Abstract xii Abbreviations xiii Chapter 1 Introduction 1 1.1 Colloids: a general introduction . 1 1.2 Transport of microscopic objects – Brownian motion and beyond . 2 1.2.1 Motion by external gradient fields . 4 1.2.2 Overcoming Brownian motion: propulsion and the requirement of symmetrybreaking............................ 7 1.3 Design & synthesis of self-phoretic anisotropic colloids . 10 1.4 Methods to analyse colloid dynamics . 13 1.4.1 2D particle tracking . 14 1.4.2 Trajectory analysis . 19 1.5 Thesisoutline................................... 24 Chapter 2 Roughening up Polymer Microspheres and their Brownian Mo- tion 32 2.1 Introduction.................................... 33 2.2 Results&Discussion............................... 38 2.2.1 Fabrication and characterization of ‘rough’ microparticles . 38 i 2.2.2 Quantifying particle surface roughness by image analysis . -
Particle Size Analysis of 99Mtc-Labeled and Unlabeled Antimony Trisulfide and Rhenium Sulfide Colloids Intended for Lymphoscintigraphic Application
Particle Size Analysis of 99mTc-Labeled and Unlabeled Antimony Trisulfide and Rhenium Sulfide Colloids Intended for Lymphoscintigraphic Application Chris Tsopelas RAH Radiopharmacy, Nuclear Medicine Department, Royal Adelaide Hospital, Adelaide, Australia nature allows them to be retained by the lymph nodes (8,9) Colloidal particle size is an important characteristic to consider by a phagocytic mechanism, yet the rate of colloid transport when choosing a radiopharmaceutical for mapping sentinel through the lymphatic channels is directly related to their nodes in lymphoscintigraphy. Methods: Photon correlation particle size (10). Particles smaller than 4–5 nm have been spectroscopy (PCS) and transmission electron microscopy reported to penetrate capillary membranes and therefore (TEM) were used to determine the particle size of antimony may be unavailable to migrate through the lymphatic chan- trisulfide and rhenium sulfide colloids, and membrane filtration (MF) was used to determine the radioactive particle size distri- nel. In contrast, larger particles (ϳ500 nm) clear very bution of the corresponding 99mTc-labeled colloids. Results: slowly from the interstitial space and accumulate poorly in Antimony trisulfide was found to have a diameter of 9.3 Ϯ 3.6 the lymph nodes (11) or are trapped in the first node of a nm by TEM and 18.7 Ϯ 0.2 nm by PCS. Rhenium sulfide colloid lymphatic chain so that the extent of nodal drainage in was found to exist as an essentially trimodal sample with a contiguous areas cannot always be discerned (5). After dv(max1) of 40.3 nm, a dv(max2) of 438.6 nm, and a dv of 650–2200 injection, the radiocolloid travels to the sentinel node 99m nm, where dv is volume diameter.