Manhole Inspection Form M2-16-36-P5-6E-9-4-1

Manhole Number M2-16-36-P5-6E-9-4-1 StructureHistoric Manhole Type Number SanitaryAdele 1 Manhole Year Installed 1978 Structure Type Sanitary Manhole Street west side Address 31525 Elevation 589.448 Weather Partly Cloudy Temperature 75° Ground Condition Dry Status At Surface Grade Location Field Pavment Condition N/A Traffic No Traffic at Location Inspector 1 JEM Inspector 2 HLW

Cover Type EJ 1040A Number of Cover Holes Solid Cover Catch Basin Cover Cover Insert No Cover Gasket Yes Cover Grade Cover is At Grade Grade Dist 0 Cover Fit Good Fit Cover Condition Good Frame Condition Good

Frame Offset 0 Frame Seal Condition Good Frame Seal Inflow None Frame Riser No Frame Riser Height Frame Riser Material N/A

Manhole Diameter 48 Manhole Depth 13.5 Chimney Depth 2.6 Chimney Construction Block Chimney Condition Good Chimney Inflow Low

Cone Shape Eccentric Cone Depth 33 Cone Construction Precast Cone Condition Good Cone Inflow None Cone Defect Location Wall/Cone Joint

Wall Construction Precast Wall Condition Good Wall Inflow Low Wall Defect Location Wall Joint Wall Defect Location 2 Wall Defect Location 3 Wall Defect Location 4 Wall Defect Location 5

Bench Construction Poured Bench Condition Good Bench Inflow None Channel Construction Poured

Channel Condition Good Channel Inflow None Channel Hydraulics Good Channel Exposure Yes Manhole Inspection Form M2-16-36-P5-6E-9-4-1

Step Construction Plastic Step Condition Good Surcharge Evidence

Pipe 1 Flow Inward Flow Pipe 1 Diameter 15 Pipe 1 Direction N Pipe 1 Depth 13.45 Pipe 1 Material Truss Pipe 1 Seal Condition Good Pipe 1 Drop Pipe 1 Comments

Pipe 2 Flow Outward Flow Pipe 2 Diameter 15 Pipe 2 Direction SE Pipe 2 Depth 13.5 Pipe 2 Material Other- See Comments Pipe 2 Seal Condition Good Pipe 2 Drop Pipe 2 Comments

Pipe 3 Flow Pipe 3 Diameter Pipe 3 Direction Pipe 3 Depth Pipe 3 Material Pipe 3 Seal Condition Pipe 3 Drop Pipe 3 Comments

Pipe 4 Flow Pipe 4 Diameter Pipe 4 Direction Pipe 4 Depth Pipe 4 Material Pipe 4 Seal Condition Pipe 4 Drop Pipe 4 Comments

Pipe 5 Flow Pipe 5 Diameter Pipe 5 Direction Pipe 5 Depth Pipe 5 Material Pipe 5 Seal Condition Pipe 5 Drop Pipe 5 Comments

Pipe 6 Flow Pipe 6 Diameter Pipe 6 Direction Pipe 6 Depth Pipe 6 Material Pipe 6 Seal Condition Pipe 6 Drop Pipe 6 Comments

Recommendation 1 Internal Chimney Seal Recommendation 2 Seal Wall Joints

Recommendation 3 Recommendation 4

Recommendation 5 Recommendation 6 Manhole Inspection Form M2-16-36-P5-6E-9-4-1

Recommendation 5 Recommendation 6

Recommendation 7 Recommendation 8

Manhole Rating 2 – Failure unlikely in 20 years Comments Cover not bolted, test well south (Good) wall. Seal 2 wall joints Manhole Inspection Form M2-16-36-P5-6E-9-4-1 Manhole Inspection Form M2-16-36-P5-6E-9-4-1 Manhole Inspection Form M2-16-36-P5-6E-9-4-1 Manhole Inspection Form M2-16-36-P5-6E-9-4-1 Manhole Inspection Form M2-16-36-P5-6E-9-4-1