On the Raman Spectrum of Plutonium Dioxide: Vibrational and Crystal Field Modes

Total Page:16

File Type:pdf, Size:1020Kb

On the Raman Spectrum of Plutonium Dioxide: Vibrational and Crystal Field Modes On the Raman Spectrum of Plutonium dioxide: vibrational and crystal field modes M. Naji1, N. Magnani1, L. J. Bonales3, S. Mastromarino1, 2, J.-Y. Colle1, J. Cobos3, D. Manara1,* 1European Commission, Joint Research Centre, Institute for Transuranium Elements, P.O. Box 2340, 76125 Karlsruhe, Germany. 2Università degli Studi di Roma "La Sapienza", Piazzale Aldo Moro 5, 00185 Rome, Italy. 3Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas, CIEMAT Avenida Complutense, 40, 28040 Madrid, Spain. The Raman spectrum of plutonium dioxide is studied both experimentally and theoretically. Particular attention has been devoted to the identification of high-energy modes at 2120 cm-1 and 2625 cm-1, whose attribution has so far been controversial. The temperature dependence of both modes suggests an electronic origin. Crystal Field (CF) calculations reported in this work shows that these two modes can be respectively assigned to the Γ1 → Γ5 and Γ1 → Γ3 CF transitions 5 within the I4 manifold. These two modes, together with the only vibrational line foreseen by the group theory for the -1 Fm-3m PuO2 symmetry – the T2g Pu-O stretching mode observed at 478 cm – can thus be used as Raman fingerprint of fcc plutonium dioxide. PACS number(s): 78.30.Am, 07.35.+k, 62.50.+p I. INTRODUCTION temperature-independent magnetic susceptibility14 is compatible with its Γ1 singlet ground state (which is Plutonium dioxide spectroscopy can have important expected from the simple argument that the CF states applications in nuclear waste management, nuclear for Pu4+ ions in a given ligand geometry should roughly forensic and safeguard activities. 1, 2 In particular, the be the inverse as those for U4+).15 However, this single- Raman spectrum of plutonium dioxide (PuO2) has been ion picture turns out to be problematic upon further studied in a few research laboratories in the last couple inspection, in particular because the energy gap of decades. 3-6 Plutonium dioxide crystallises in the fcc between the two lowest CF levels detected by inelastic fluorite-like structure, belonging to the Fm-3m space neutron scattering (INS) is much smaller than the value group. The factor group theory at the Γ point for this which was estimated from magnetic measurements (in type of crystal symmetry was fully derived by order to maintain a constant paramagnetic susceptibility Shimanouchi et al. 7. It foresees only one triply up to 1000 K); this issue is still an open problem today. degenerate T2g (LO1) Raman active vibrational mode, It must be remarked that INS is only sensitive to the Γ1 and one infrared active T1u mode at a lower energy. → Γ4 transition, and a complete spectroscopic 5 Since the work by Shimanouchi et al., these modes have investigation of the lowest I4 manifold is still lacking been experimentally observed for various actinide and would be highly desirable in order to test it against dioxides and other fluorite-like materials,8-11 including current theories. plutonium dioxide. 4, 5, 12 However, the Raman spectrum Experimentally, in addition to INS, electronic Raman of plutonium dioxide was reported up to higher Raman scattering (ERS) played a crucial role to determine the -1 12 16 shift energies (beyond 1500 cm ) only recently. A few various split LSJ manifolds of the 4,5f ions. In UO2, crucial features of the high-energy part of the PuO2 ERS elucidate the manifestation of the strong electron– Raman spectrum remain to-date unclarified, which has phonon interactions in the resonant coupling between ′ ′ 4+ not permitted a satisfactory definition of a precise nLO (n = 1–4) phonons and 3퐻4 → 3퐹2 U Raman fingerprint for PuO2. Among those features, the intermultiplet CF excitations. Consequently, one would most remarkable are two strong peaks consistently expect that the Raman effect would be of some interest 12 -1 observed by Sarsfield et al. at 2120 ± 10 cm and in the study of CF transitions in PuO2. 2620 ± 10 cm-1. Despite some attempts, the nature of The experimental part of this study was carried out these two lines could not be clearly defined. Sarsfield with the help of an original encapsulation technique, et al. 12 analysed in depth various possible attributions described in a very recent publication.17 Among other for them, both in terms of higher-order phonon things, this technique permits, for the investigation of combinations and surface impurity modes, but could not such highly radioactive materials, the use of different find any satisfactory assignment. Finally, these authors excitation laser sources, and the employment of the suggested that these lines might have an electronic triple subtractive spectrometer configuration. The first origin. feature is important for the analysis of resonant and In this respect, there is a vast literature discussing the energy dispersive modes and for the detection of crystal field (CF) potential of UO2 and NpO2, fluorescence features in the Raman spectra; the second particularly in relation to their peculiar low-temperature is necessary for the study of low-energy Raman lines 13 magnetic properties. Less attention has been devoted and anti-Stokes peaks. In particular, the study of the T2g to PuO2, mainly because, at a first sight, its anti-Stokes band, carried out in this research for the 1 very first time on PuO2 in parallel to the Stokes in this research is a Jobin-Yvon T 64000 equipped with spectrum, allowed us to reasonably estimate a a 1800 grooves per mm grating, a low noise liquid temperature dependence of the observed Raman modes, nitrogen cooled symphony CCD detector, a subtractive especially the above-mentioned high-energy bands. pre-monochromator (in triple mode) which allows Moreover, CF calculations performed in the present access to anti-Stokes spectrum lines while blocking the research soundly support the attribution of these high- elastic Rayleigh line. Excitation sources used in this energy lines to PuO2 CF transitions. Such a conclusion, work are the 488 nm (2.53 eV) or 514.5 nm (2.41 eV) together with the already sound theoretical and lines of an Ar+ Coherent® Continuous Wave (CW) experimental description of the vibrational part of the laser or the 647 nm (1.91 eV) or 752 nm (1.65 eV) lines Raman spectrum, allows us to propose a consistent of a similar Kr+ laser. Both laser sources have a Raman fingerprint for plutonium dioxide. controllable nominal power up to 1.5 W. Typical laser power values at the sample surface ranged between 5 II. EXPERIMENTAL METHODS mW and 300 mW, whereby the highest power values were used in order to heat the sample in situ. The power A. Samples impinging the sample surface was measured by a Coherent® power-meter placed at a position The current Raman spectroscopy measurements were corresponding to the sample surface. It is lower by performed on a solid polycrystalline PuO2 disk, approximately a factor 5 than the actual power at the prepared following the procedure described by De exit of the laser cavity. Using the long focal x50 Bruycker et al. 18 The starting material was based on objective and the single spectrometer mode permits a beads obtained by gel-supported precipitation (SOL– good spectral resolution (± 1 cm-1) independently of the GEL). A disk-shaped sample of 8–9 mm in diameter surface shape, with a spatial resolution of 2 µm x 2µm and about 1 mm in thickness was obtained using a bi- on the sample surface. The spectrograph is calibrated directional press. The samples were then sintered in an with the T2g excitation of a silicon single crystal, set at -1 20 atmosphere of Ar + H2 with 1500 ppm of H2O to obtain 520.5 cm . The instrument is calibrated on a daily dense material. In order to obtain stoichiometric basis prior to measurements. material (O/M=2.00) and remove the defects produced during the fabrication, the PuO2 sample was subjected C. Temperature determination to two consecutive heat treatments under a flow of air at 1423 K for 8 hours. Already after the first heat a) Stokes and anti-Stokes Raman peak analysis treatment the measured weight gain of the sample corresponded to stoichiometric PuO2 separately For Raman laser heating experiments, the Raman measured by thermo-gravimetry (TG). Since, in laser was used as an excitation and heating source. The addition, no further change was noticed after annealing laser power was then increased stepwise and the the samples for a second time, it was considered that Stokes/anti-Stokes Raman spectra were collected at PuO2.00 stoichiometry had been reached. A lattice different powers. parameter of 0.5396(1) Å was measured by X-ray The absolute temperature (TSAS) was derived from the diffraction (XRD), corresponding to the literature value ratio (RSAS) between the experimental intensities of the 19 for PuO2. The average crystallite size measured by anti-Stokes and Stokes T2g peaks according to Bose- XRD and estimated with the help of scanning electron Einstein statistics. Prior to these calculations, Stokes microscopy (SEM) on a polished surface, was (5 ± 3) and anti-Stokes Raman spectra were corrected for the µm. instrumental response according to the procedure The isotopic composition of the plutonium employed described elsewhere.21, 22 Despite the instrumental was checked by High Resolution Gamma Spectroscopy correction, the value of TSAS can represent the real (HRGS) to be 93.4 wt.% 239Pu and 6.4 wt.% 240Pu. sample temperature in a rather inaccurate fashion, due Traces (<0.2 wt.%) of 241Pu and 241Am stemming from to uncontrollable sample-dependent factors affecting the β-decay of 241Pu were detected by Thermal Ionisation intensities of the Stokes and anti-Stokes lines, such as Mass Spectrometry (TIMS). impurity fluorescence, roughness scattering etc. Therefore, the value of TSAS should be considered as B.
Recommended publications
  • Experimental Γ Ray Spectroscopy and Investigations of Environmental Radioactivity
    Experimental γ Ray Spectroscopy and Investigations of Environmental Radioactivity BY RANDOLPH S. PETERSON 216 α Po 84 10.64h. 212 Pb 1- 415 82 0- 239 β- 01- 0 60.6m 212 1+ 1630 Bi 2+ 1513 83 α β- 2+ 787 304ns 0+ 0 212 α Po 84 Experimental γ Ray Spectroscopy and Investigations of Environmental Radioactivity Randolph S. Peterson Physics Department The University of the South Sewanee, Tennessee Published by Spectrum Techniques All Rights Reserved Copyright 1996 TABLE OF CONTENTS Page Introduction ....................................................................................................................4 Basic Gamma Spectroscopy 1. Energy Calibration ................................................................................................... 7 2. Gamma Spectra from Common Commercial Sources ........................................ 10 3. Detector Energy Resolution .................................................................................. 12 Interaction of Radiation with Matter 4. Compton Scattering............................................................................................... 14 5. Pair Production and Annihilation ........................................................................ 17 6. Absorption of Gammas by Materials ..................................................................... 19 7. X Rays ..................................................................................................................... 21 Radioactive Decay 8. Multichannel Scaling and Half-life .....................................................................
    [Show full text]
  • Nuclear Engineering and Technology 49 (2017) 1489E1494
    Nuclear Engineering and Technology 49 (2017) 1489e1494 Contents lists available at ScienceDirect Nuclear Engineering and Technology journal homepage: www.elsevier.com/locate/net Original Article Large-volume and room-temperature gamma spectrometer for environmental radiation monitoring * Romain Coulon , Jonathan Dumazert, Tola Tith, Emmanuel Rohee, Karim Boudergui CEA, LIST, F-91191 Gif-sur-Yvette Cedex, France article info abstract Article history: The use of a room-temperature gamma spectrometer is an issue in environmental radiation monitoring. Received 29 April 2016 To monitor radionuclides released around a nuclear power plant, suitable instruments giving fast and Received in revised form reliable information are required. High-pressure xenon (HPXe) chambers have range of resolution and 15 May 2017 efficiency equivalent to those of other medium resolution detectors such as those using NaI(Tl), CdZnTe, Accepted 4 June 2017 and LaBr :Ce. An HPXe chamber could be a cost-effective alternative, assuming temperature stability and Available online 3 July 2017 3 reliability. The CEA LIST actively studied and developed HPXe-based technology applied for environ- mental monitoring. Xenon purification and conditioning was performed. The design of a 4-L HPXe de- Keywords: Xenon tector was performed to minimize the detector capacitance and the required power supply. Simulations fi Spectrometry were done with the MCNPX2.7 particle transport code to estimate the intrinsic ef ciency of the HPXe Environmental detector. A behavioral study dealing with ballistic deficits and electronic noise will be utilized to provide Detector perspective for further analysis. Radiation © 2017 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the Ionization chamber CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
    [Show full text]
  • 19 International Workshop on Low Temperature Detectors
    19th International Workshop on Low Temperature Detectors Program version 1.24 - Moscow Standard Time 1 Date Time Session Monday 19 July 16:00 - 16:15 Introduction and Welcome 16:15 - 17:15 Oral O1: Devices 1 17:15 - 17:25 Break 17:25 - 18:55 Oral O1: Devices 1 (continued) 18:55 - 19:05 Break 19:05 - 20:00 Poster P1: MKIDs and TESs 1 Tuesday 20 July 16:00 - 17:15 Oral O2: Cold Readout 17:15 - 17:25 Break 17:25 - 18:55 Oral O2: Cold Readout (continued) 18:55 - 19:05 Break 19:05 - 20:30 Poster P2: Readout, Other Devices, Supporting Science 1 22:00 - 23:00 Virtual Tour of NIST Quantum Sensor Group Labs Wednesday 21 July 16:00 - 17:15 Oral O3: Instruments 17:15 - 17:25 Break 17:25 - 18:55 Oral O3: Instruments (continued) 18:55 - 19:05 Break 19:05 - 20:30 Poster P3: Instruments, Astrophysics and Cosmology 1 20:00 - 21:00 Vendor Exhibitor Hour Thursday 22 July 16:00 - 17:15 Oral O4A: Rare Events 1 Oral O4B: Material Analysis, Metrology, Other 17:15 - 17:25 Break 17:25 - 18:55 Oral O4A: Rare Events 1 (continued) Oral O4B: Material Analysis, Metrology, Other (continued) 18:55 - 19:05 Break 19:05 - 20:30 Poster P4: Rare Events, Materials Analysis, Metrology, Other Applications 22:00 - 23:00 Virtual Tour of NIST Cleanoom Tuesday 27 July 01:00 - 02:15 Oral O5: Devices 2 02:15 - 02:25 Break 02:25 - 03:55 Oral O5: Devices 2 (continued) 03:55 - 04:05 Break 04:05 - 05:30 Poster P5: MMCs, SNSPDs, more TESs Wednesday 28 July 01:00 - 02:15 Oral O6: Warm Readout and Supporting Science 02:15 - 02:25 Break 02:25 - 03:55 Oral O6: Warm Readout and Supporting
    [Show full text]
  • Supplement to The
    Hahn-Meitner-Institut Berlin Supplement to the Annual Report 2001 Berlin 2002 Supplement Index Publications 3 Structural Research 4 Solar Energy Research 21 Information Technology 30 Conference Contributions / Invited Lectures 31 Structural Research 32 Solar Energy Research 62 Information Technology 77 Technology Transfer / Patents 79 Academic Education 83 Courses 84 Exams 87 Co-operation Partners and Guests 89 Structural Research 90 Solar Energy Research 99 Information Technology 103 External Funding 105 Structural Research 106 Solar Energy Research 108 Participation in External Scientific Bodies and Committees 111 Miscellaneous 115 Awards / Exhibitions / Fairs / Organization of Conferences and Meetings / Events 1. Edition June 2002 Supplement of the Annual Report 2001 HMI-B 585 Hahn-Meitner-Institut Berlin GmbH Glienicker Str. 100 D-14109 Berlin (Wannsee) Coordination: Maren Achilles Phone: +49 – (0)30 – 8062 2668 Fax: +49 – (0)30 – 8062 2047 E-mail: [email protected] A 2 HMI Annual Report 2001 Publications 2001 Publications HMI Annual Report 2001 A 3 Publications 2001 Structural Research Department SF1 Pappas, C.; Kischnik, R.; Mezei, F. Wide angle NSE : the spectrometer SPAN at Instruments and Methods BENSC Physica B 297 (2001) 14-17 Pappas, C.; Mezei, F. Reviewed Publications How to achieve high intensity in NSE spectros- copy? BENSC-Activities Proceedings of the ILL Millenium Workshop, 2001, p.318 Ehlers, G.; Farago, B;. Pappas, C; Mezei, F. A new IN11 with an almost 35 times higher Peters, J.; Treimer, W. counting rate than that of IN11C Bloch walls in a nickel single crystal Proceedings of the ILL Millenium Workshop, 2001 p. Phys. Rev. B 64 (2001) 214415 – 214422 316 Scheffer, M.; Rouijaa, M.; Suck, J.-B.; Sterzel, R.; Fitzsimmons, M.
    [Show full text]
  • Gamma Ray Spectroscopy
    Gamma Ray Spectroscopy Ian Rittersdorf Nuclear Engineering & Radiological Sciences [email protected] March 20, 2007 Rittersdorf Gamma Ray Spectroscopy Contents 1 Abstract 3 2 Introduction & Objectives 3 3 Theory 4 3.1 Gamma-Ray Interactions . 5 3.1.1 Photoelectric Absorption . 5 3.1.2 Compton Scattering . 6 3.1.3 Pair Production . 8 3.2 Detector Response Function . 9 3.3 Complications in the Response Function . 11 3.3.1 Secondary Electron Escape . 11 3.3.2 Bremsstrahlung Escape . 12 3.3.3 Characteristic X-Ray Escape . 12 3.3.4 Secondary Radiations Created Near the Source . 13 3.3.5 Effects of Surrounding Materials . 13 3.3.6 Summation Peaks . 14 3.4 Semiconductor Diode Detectors . 15 3.5 High Purity Germanium Semiconductor Detectors . 17 3.5.1 HPGe Geometry . 18 3.6 Germanium Detector Setup . 18 3.7 Energy Resolution . 19 3.8 Background Radiation . 20 4 Equipment List 21 5 Setup & Settings 21 6 Analysis 23 6.1 Prominent Peak Information . 24 6.2 Calibration Curve . 24 6.3 Experiment Part 6 – 57Co ............................ 26 6.4 Experiment Part 6 – 60Co ............................ 28 6.5 Experiment Part 6 – 137Cs............................ 29 6.6 Experiment Part 6 – 22Na ............................ 31 6.7 Experiment Part 6 – 133Ba............................ 32 6.8 Experiment Part 6 – 109Cd............................ 34 6.9 Experiment Part 6 – 54Mn............................ 35 6.10 Energy Resolution . 37 6.11 Background Analysis . 39 1 Rittersdorf Gamma Ray Spectroscopy 7 Conclusions 43 Appendices i A 57Co Decay Scheme i B 60Co Decay Scheme ii C 137Cs Decay Scheme iii D 22Na Decay Scheme iv E 133Ba Decay Scheme v F 109Cd Decay Scheme vi G 54Mn Decay Scheme vii H HPGe Detector Apparatus viii I Raw Gamma-Ray Spectra ix References ix 2 Rittersdorf Gamma Ray Spectroscopy 1 Abstract In lab, a total of eight spectra were measured.
    [Show full text]
  • Detecting, Monitoring, and Sampling Hazardous Materials
    Analyzing the Incident: Detecting, Monitoring, and Sampling Hazardous Materials Chapter Contents Exposure .......................................161 Thermal Imagers .......................................................188 Routes of Entry ..........................................................161 Infrared Thermometers .............................................188 Contamination versus Exposure ...............................162 Other Detection Devices .....................189 Acute versus Chronic Exposure ................................163 Halogenated Hydrocarbon Meters ............................189 Radiological and Biological Exposures ...164 Flame Ionization Detectors ........................................190 Exposure Limits .........................................................164 Gas Chromatography .................................................190 Radiological Exposures .............................................168 Mass Spectroscopy ...................................................191 Biological Exposures .................................................169 Ion Mobility Spectrometry ........................................192 Sensor-Based Instruments and Surface Acoustic Wave ..............................................192 Other Devices ...............................170 Gamma-Ray Spectrometer ........................................193 Oxygen Indicators .....................................................170 Fourier Transform IR .................................................194 Combustible Gas Indicators
    [Show full text]
  • Testing FLUKA on Neutron Activation of Si and Ge at Nuclear Research Reactor Using Gamma Spectroscopy
    Testing FLUKA on neutron activation of Si and Ge at nuclear research reactor using gamma spectroscopy J. Bazoa, J.M. Rojasa, S. Besta, R. Brunab, E. Endressa, P. Mendozac, V. Pomac, A.M. Gagoa aSecci´onF´ısica, Departamento de Ciencias, Pontificia Universidad Cat´olica del Per´u,Av. Universitaria 1801, Lima 32, Per´u bC´alculoAn´alisisy Seguridad (CASE), Instituto Peruano de Energ´ıaNuclear (IPEN), Av. Canad´a1470, Lima 41, Per´u cDivisi´onde T´ecnicas Anal´ıticas Nucleares, Instituto Peruano de Energ´ıaNuclear (IPEN), Av. Canad´a1470, Lima 41, Per´u Abstract Samples of two characteristic semiconductor sensor materials, silicon and ger- manium, have been irradiated with neutrons produced at the RP-10 Nuclear Research Reactor at 4.5 MW. Their radionuclides photon spectra have been measured with high resolution gamma spectroscopy, quantifying four radioiso- topes (28Al, 29Al for Si and 75Ge and 77Ge for Ge). We have compared the radionuclides production and their emission spectrum data with Monte Carlo simulation results from FLUKA. Thus we have tested FLUKA's low energy neutron library (ENDF/B-VIIR) and decay photon scoring with respect to the activation of these semiconductors. We conclude that FLUKA is capable of pre- dicting relative photon peak amplitudes, with gamma intensities greater than 1%, of produced radionuclides with an average uncertainty of 13%. This work allows us to estimate the corresponding systematic error on neutron activation simulation studies of these sensor materials. Keywords: FLUKA, neutron irradiation, nuclear reactor, silicon, germanium arXiv:1709.02026v2 [physics.ins-det] 21 Dec 2017 ∗Corresponding author Email address: [email protected] (J.
    [Show full text]
  • Progress in Investigation of Wwer-440 Reactor Pressure Vessel Steel by Gamma and Mossbauer Spectroscopy
    HR9800123 PROGRESS IN INVESTIGATION OF WWER-440 REACTOR PRESSURE VESSEL STEEL BY GAMMA AND MOSSBAUER SPECTROSCOPY J. Hascik1. V. Slugen', J. Lipka1, RKupca2, R Hinca', I. Toth', R Grone', P. Uvacik1 'Department of Nuclear Physics and Technology, Slovak University of Technology, Ilkovicova3, 81219 Bratislava, Slovakia 2NPP Research Institute, Trnava, Okruznd 5, Slovakia Abstract Gramma spectroscopic analyse and first experimental results of original irradiated reactor pressure vessel surveillance specimens are discussed in . In 1994, the new "Extended Surveillance Specimen Program for Nuclear Reactor Material Study" was started in collaboration with the nuclear power plants (NPP) V-2 Bohunice (Slovakia). The first batch of MS samples (after 1 year, which is equivalent to 5 years of loading RPV-steel) was measured and interpreted using the new four components approach with the aim to observe microstructural changes due to thermal and neutron treatment resulting from operating conditions in NPP. The systematic changes in the relative areas of Mossbauer spectra components were observed. 1 INTRODUCTION The reactor pressure vessel (RPV) is probably the most important component of a nuclear power plant (NPP) and its condition significantly affects the NPP's lifetime and operational characteristics. One of the basic requirements in nuclear reactor technique is ensuring the sufficient safety margin and reliability of used materials during their operational mechanical, thermal or radiation treatment [1]. In framework of Extended Surveillance Specimen Program 24 specimens, designed especially for MS measurement, were selected and measured in "as received" state, before their placement into the core of the operated nuclear reactor. Mossbauer spectra, which correspond to the basic material samples, show typical behaviour of dilute iron alloys and can be described with three [2,3] or four sextets.
    [Show full text]
  • Devices of Basic and Applied Scientific Research Center
    أﺟﻬﺰة ﻣﺮﻛﺰ اﻟﺒﺤﻮث اﻟﻌﻠﻤﻴﺔ اﺳﺎﺳﻴﺔ و اﻟﺘﻄﺒﻴﻘﻴﺔ Devices of Basic and Applied Scientic Research Center Done by 2018 Ibtisam H. Al-Qahtani Content Introduction Research units labs information Key Devises at the Research Units Labs Research Units Labs Services Gamma -ray Spectroscopy X-Ray Diffractometer (XRD- 7000) Organic Elemental Analyzer Tot al Organic Carbon Analyzer (TOC) Fourier Transform Infrared Analysis System- (FTIR) Gas Chromatography – Mass spectrometer (GC-MS/MS) Microwave Digestion System Thermo-Gravimetric Analyzer (TGA) UV SolidSpec-3700 Inductively Coupled Plasma (ICP) LCMS - 8040 with APCI High Energy E-max Ball Energy Dispersive -X Ray Fluorescence spectrometers (EDXRF) Automated Surface Area Analyzer DXR Raman Microscope Analytical Scanning Electron Microscopy (VEGA 3) Atomic Absorption Spectrophotometer (AAS) TASLIMAGE Radon Dosimetry System Flash Chromatography Ion Chromatography System S 153- A Dual GasChromatograph (GC-2014 ) VITEK® 2 Compact DAKO ARTIZAN (Multi Strainer) DAKO Hematoxylin 1 - Introductiongreat atte lies in the scientific, intellectual and behavioural capacities of its sons . The need for Thestudies, Kingdom research of Saudi and Arabia learning has recently has become taken serious a cornerstone steps and insteps life toto reach thestrengthen greatest its possible position knowledge in science and of technology,the sciences achieve that ensureeconomic the renaissance well-being and of the humanaddress being, the andmost ensure important the problems superiority it faces of others,at the national as developed level . countries pay great attentionThese to scientific efforts stem research from the for desire its realization of good leadership that the togreatness move from of a nations natural lies in the scientific, intellectual and behavioural capacities of its sons.
    [Show full text]
  • Experiment 3 Gamma-Ray Spectroscopy Using Nai(Tl)
    ORTEC ® Experiment 3 Gamma-Ray Spectroscopy Using NaI(Tl) Equipment Required • SPA38 Integral Assembly consisting of a 38 mm x 38 mm • RSS8 * Gamma Source Set. Includes ~1 µCi each of: 60 Co, 137 Cs, NaI(Tl) Scintillator, Photomultiplier Tube, and PMT Base with 22 Na, 54 Mn, 133 Ba, 109 Cd, 57 Co, and a mixed Cs/Zn source (~0.5 Stand µCi 137 Cs, ~1 µCi 65 Zn). The first three are required in this • 4001A/4002D NIM Bin and Power Supply experiment. An unknown for Experiment 3.2 can be selected from the remaining sources. • 556 High Voltage Bias Supply • GF-137-M-5 * 5 µCi ±5% 137 Cs Gamma Source (used as a • 113 Scintillation Preamplifier reference standard for activity in Experiment 3.5). • 575A Spectroscopy Amplifier • GF-057-M-20 * 20 µCi 57 Co Source (for Experiment 3.9). • EASY-MCA-2K including USB cable and MAESTRO software • One each of pure metal foil absorber sets: FOIL-AL-30 , FOIL- (other ORTEC MCAs may be substituted) FE-5 , FOIL-CU-10 , FOIL-MO-3 , FOIL-SN-4 , and FOIL-TA-5 . • Personal Computer with a USB port and a recent, supportable Each set contains 10 identical foils of the designated pure version of the Windows operating system. element and thickness in thousandths of an inch (Foil-Element- Thickness). • TDS3032C Oscilloscope with a bandwidth ≥150 MHz. • RAS20 Absorber Foil Kit containing 5 lead absorbers from 1100 • C-34-12 RG-59A/U 75- Ω Cable with one SHV female plug and to 7400 mg/cm 2.
    [Show full text]
  • FY-2010 Process Monitoring Technology Final Report
    PNNL-20022 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 FY-2010 Process Monitoring Technology Final Report CR Orton JJ Henkel JM Peterson SA Bryan JM Schwantes DE Verdugo AJ Casella EA Jordan RN Christensen JW Hines AM Lines SM Peper TG Levitskaia CG Fraga January 2011 PNNL-20022 FY-2010 Process Monitoring Technology Final Report CR Orton1 JJ Henkel3 JM Peterson1 SA Bryan1 JM Schwantes1 DE Verdugo1 AJ Casella1 EA Jordan1 RN Christensen2 JW Hines3 AM Lines1 SM Peper1 TG Levitskaia1 CG Fraga1 January 2011 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Pacific Northwest National Laboratory Richland, Washington 99352 1 Pacific Northwest National Laboratory, Richland, Washington 2 The Ohio State University, Columbus, Ohio 3 University of Tennessee, Knoxville, Tennessee Executive Summary The diversion of special nuclear materials (SNM) and the monitoring of process conditions within nuclear reprocessing facilities are of significant interest to international safeguards facility regulators (e.g., the International Atomic Energy Agency (IAEA)) as well as nuclear material reprocessing facility operators. For large throughput nuclear facilities, such as commercial reprocessing plants, it is difficult to satisfy the IAEA safeguards accountancy goal for detection of abrupt diversion. Process monitoring helps detect diversion by using process control measurements to detect abnormal plant operation. In recent years, the Office of Nuclear Safeguards and Security (NA-241) at the National Nuclear Security Administration (NNSA) has funded a Process Monitoring Working Group (PMWG) to study various mechanisms for diverting nuclear material from spent nuclear fuel (SNF) reprocessing facilities. Common approaches for diverting special nuclear material can occur via removal of separated bulk nuclear materials, or more likely, from minor modifications to processing conditions.
    [Show full text]
  • Other Major Instrumentation
    Major instrumentation, Department of Chemistry & Biochemistry - August 18, 2021 Category Instrument 1. Spectroscopy Agilent 6530 q-TOF LC/MS Diamond ATR Golden Gate Accessory 7700 Agilent ICP-MS inductively coupled plasma-mass spectrometer with laser ablation interface Thermo Nicolet Nexus 6700 FT-IR with HATR accessory Thermo Nicolet 380 FT-IR infrared spectrometer Thermo Nicolet Nexus 6700 FT-IR Bruker Avance 600 MHz NMR with Broadband and Variable Temperature Capabilities + $3,000 2013 workstation upgrade. Bruker Vertex 70 FT-IR Rudolph Research Polarimeter JEOL JMS-T100DART AccuTOF Mass Spectrometer with AP-MALDI and ESI Power Technology Laser system, Diod laser blue 405 nm and 50 MW outtput Beckmann Coulter Fluorescence DTX 880 multimode Plate Reader Thermo Nanodrop Spectrometer Biotek H4 Microplate Spectrophotometer Agilent Diode Array 8453 Spectrophotometer Quantech Fluorometer Biotek Eon Microplate Spectrophotometer RBD Sputter gun and accessories Hiden Analytical Mass Spectrometer and UHV chamber and Accessories Vacuum Pumps 16 inch spherical UHV chamber CHAM-5-16 Bruker DPX-300 NMR with QNP and Broadband Probes, and VT Accessory McAllister Tech Services - XYZ Manipulator system MB3004-SP Lamba Bio+ UV/Vis Spectrophotometers (SN 3104) Oriel Instruments Nitrogen Laser Shimadzu UV-1601 UV-Vis Spectrophotometer (SN A10753782123) Shimadzu UV-1601 UV-Vis Spectrophotometer SpectraTech Inspect IR LSI Nitrogen Laser Nicolet Avatar 370 FT-IR infrared spectrometer Agilent Diode Array 8453 Spectrophotometer Lambda 35 UV-Vis Spectrophotometer
    [Show full text]