Fluorolog®-3 with Fluoressence™

Total Page:16

File Type:pdf, Size:1020Kb

Fluorolog®-3 with Fluoressence™ Fluorolog-3 Operation Manual rev. G (2 May 2014) Fluorolog®-3 with FluorEssence™ Operation Manual www.HORIBA.com/scientific rev. G i Fluorolog-3 Operation Manual rev. G (2 May 2014) Copyright © 2002–2014 by HORIBA Instruments Incorporated. All rights reserved. No part of this work may be reproduced, stored, in a retrieval system, or transmitted in any form by any means, including electronic or mechanical, photocopying and recording, without prior written permission from HORIBA Instruments Incorporated. Requests for permission should be requested in writing. Origin® is a registered trademark of OriginLab Corporation. Alconox® is a registered trademark of Alconox, Inc. Ludox® is a registered trademark of W.R. Grace and Co. Teflon® is a registered trademark of E.I. du Pont de Nemours and Company. Windows® and Excel® are registered trademarks of Microsoft Corporation. Information in this manual is subject to change without notice, and does not represent a commitment on the part of the vendor. May 2014 Part number J81014 ii Fluorolog-3 Operation Manual rev. G (2 May 2014) Table of Contents 0: Introduction ................................................................................................. 0-1 About the Fluorolog®-3 ........................................................................................................................... 0-1 Chapter overview .................................................................................................................................... 0-2 Disclaimer ............................................................................................................................................... 0-4 Safety summary ...................................................................................................................................... 0-6 Risks of ultraviolet exposure ................................................................................................................... 0-9 Additional risks of xenon lamps ............................................................................................................ 0-11 1: Requirements & Installation ............................................................................. 1-1 Surface requirements ............................................................................................................................ 1-1 Environmental requirements. .................................................................................................................. 1-2 Electrical requirements .......................................................................................................................... 1-3 Installation ............................................................................................................................................... 1-4 2: System Description ....................................................................................... 2-1 Overview ................................................................................................................................................. 2-1 Configurations ......................................................................................................................................... 2-3 3: System Operation ......................................................................................... 3-1 Turning on the system ............................................................................................................................ 3-1 Checking system performance ............................................................................................................... 3-3 Useful materials for characterizing system and samples ..................................................................... 3-16 4: Data Acquisition ............................................................................................ 4-1 Introduction ............................................................................................................................................. 4-1 Experiment Menu button......................................................................................................................... 4-2 Previous Experiment Setup button ......................................................................................................... 4-4 Auto Run Previous Experiment button ................................................................................................... 4-5 Make Overlay File button ........................................................................................................................ 4-6 3D Scan to 3D Profile button ................................................................................................................. 4-7 Run JY Batch Experiments button .......................................................................................................... 4-9 Real Time Control button ...................................................................................................................... 4-11 Create/Use Calibration Curve from CWA Data button ......................................................................... 4-12 2D Intensity Map button ........................................................................................................................ 4-16 Launch DataStation button ................................................................................................................... 4-17 Running an unknown sample ............................................................................................................... 4-18 Using corrected signals in FluorEssence™ .......................................................................................... 4-23 5: Optimizing Data ........................................................................................... 5-1 Cuvette preparation ............................................................................................................................... 5-1 Sample preparation ............................................................................................................................... 5-2 Running a scan on a sample .................................................................................................................. 5-4 Data collection techniques ...................................................................................................................... 5-6 Correcting data ..................................................................................................................................... 5-12 6: System Maintenance ..................................................................................... 6-1 External Case ........................................................................................................................................ 6-1 Lamp-housing exhaust filters .................................................................................................................. 6-1 Xenon lamp ............................................................................................................................................. 6-2 Installing an optional new photomultiplier tube ..................................................................................... 6-17 Reference signal detector ..................................................................................................................... 6-18 Gratings ................................................................................................................................................ 6-19 Mirrors ................................................................................................................................................... 6-22 Automated 4-position turret .................................................................................................................. 6-23 iii Fluorolog-3 Operation Manual rev. G (2 May 2014) 7: Troubleshooting ............................................................................................ 7-1 Chart ....................................................................................................................................................... 7-1 Using diagnostic spectra ....................................................................................................................... 7-3 Further assistance .................................................................................................................................. 7-8 8: Producing Correction Factors ........................................................................... 8-1 Introduction ............................................................................................................................................. 8-1 Types of Correction-Factor Kits .............................................................................................................. 8-2 Generating emission correction factors with the F-3026 Correction Factor Kit ...................................... 8-3 Calculating emission correction factors .................................................................................................. 8-8 Calculating excitation correction factors ................................................................................................. 8-9 Using correction-factor files .................................................................................................................
Recommended publications
  • Glossary Physics (I-Introduction)
    1 Glossary Physics (I-introduction) - Efficiency: The percent of the work put into a machine that is converted into useful work output; = work done / energy used [-]. = eta In machines: The work output of any machine cannot exceed the work input (<=100%); in an ideal machine, where no energy is transformed into heat: work(input) = work(output), =100%. Energy: The property of a system that enables it to do work. Conservation o. E.: Energy cannot be created or destroyed; it may be transformed from one form into another, but the total amount of energy never changes. Equilibrium: The state of an object when not acted upon by a net force or net torque; an object in equilibrium may be at rest or moving at uniform velocity - not accelerating. Mechanical E.: The state of an object or system of objects for which any impressed forces cancels to zero and no acceleration occurs. Dynamic E.: Object is moving without experiencing acceleration. Static E.: Object is at rest.F Force: The influence that can cause an object to be accelerated or retarded; is always in the direction of the net force, hence a vector quantity; the four elementary forces are: Electromagnetic F.: Is an attraction or repulsion G, gravit. const.6.672E-11[Nm2/kg2] between electric charges: d, distance [m] 2 2 2 2 F = 1/(40) (q1q2/d ) [(CC/m )(Nm /C )] = [N] m,M, mass [kg] Gravitational F.: Is a mutual attraction between all masses: q, charge [As] [C] 2 2 2 2 F = GmM/d [Nm /kg kg 1/m ] = [N] 0, dielectric constant Strong F.: (nuclear force) Acts within the nuclei of atoms: 8.854E-12 [C2/Nm2] [F/m] 2 2 2 2 2 F = 1/(40) (e /d ) [(CC/m )(Nm /C )] = [N] , 3.14 [-] Weak F.: Manifests itself in special reactions among elementary e, 1.60210 E-19 [As] [C] particles, such as the reaction that occur in radioactive decay.
    [Show full text]
  • Fluorescence Spectroscopy and Chemometrics in the Food Classification − a Review
    Czech J. Food Sci. Vol. 25, No. 4: 159–173 Fluorescence Spectroscopy and Chemometrics in the Food Classification − a Review Jana SÁDECKÁ and Jana TÓTHOVÁ Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology, Bratislava, Slovak Republic Abstract Sádecká J., Tóthová J. (2007): Fluorescence spectroscopy and chemometrics in the food classification − a review. Czech J. Food Sci., 25: 159–173. This review deals with the last few years’ articles on various fluorescence techniques (conventional, excitation-emis- sion matrix, and synchronous fluorescence spectroscopy) as a tool for the classification of food samples. Chemometric methods as principal component analysis, hierarchical cluster analysis, parallel factor analysis, and factorial discrimi- nate analysis are briefly reminded. The respective publications are then listed according to the food samples: dairy products, eggs, meat, fish, edible oils, and others. Keywords: chemometrics; fluorescence spectroscopy; food analysis Fluorescence spectroscopy is a rapid, sensitive, distinguish. The analytical information contained and non-destructive analytical technique pro- in fluorescence spectra can be extracted by using viding in a few seconds spectral signatures that various multivariate analysis techniques that relate can be used as fingerprints of the food products several analytical variables to the properties of (dairy products, fishes, edible oils, wines, etc.). the analyte(s). The multivariate techniques most The application of fluorescence in food analysis frequently used allow to group the samples with has increased during the last decade, probably similar characteristics, to establish classification due to the propagated use of chemometrics. The methods for unknown samples (qualitative analysis) study by Norgaard (1995) can serve as a general or to perform methods determining some proper- investigation of how to enhance the potential of ties of unknown samples (quantitative analysis).
    [Show full text]
  • Comparison of Life-Cycle Analyses of Compact Fluorescent and Incandescent Lamps Based on Rated Life of Compact Fluorescent Lamp
    Comparison of Life-Cycle Analyses of Compact Fluorescent and Incandescent Lamps Based on Rated Life of Compact Fluorescent Lamp Laurie Ramroth Rocky Mountain Institute February 2008 Image: Compact Fluorescent Lamp. From Mark Stozier on istockphoto. Abstract This paper addresses the debate over compact fluorescent lamps (CFLs) and incandescents through life-cycle analyses (LCA) conducted in the SimaPro1 life-cycle analysis program. It compares the environmental impacts of providing a given amount of light (approximately 1,600 lumens) from incandescents and CFLs for 10,000 hours. Special attention has been paid to recently raised concerns regarding CFLs—specifically that their complex manufacturing process uses so much energy that it outweighs the benefits of using CFLs, that turning CFLs on and off frequently eliminates their energy-efficiency benefits, and that they contain a large amount of mercury. The research shows that the efficiency benefits compensate for the added complexity in manufacturing, that while rapid on-off cycling of the lamp does reduce the environmental (and payback) benefits of CFLs they remain a net “win,” and that the mercury emitted over a CFL’s life—by power plants to power the CFL and by leakage on disposal—is still less than the mercury that can be attributed to powering the incandescent. RMI: Life Cycle of CFL and Incandescent 2 Heading Page Introduction................................................................................................................... 5 Background...................................................................................................................
    [Show full text]
  • Building a Photomultiplier Tube Testing Lab and Measuring Dark Rate
    Building a photomultiplier tube testing lab and measuring dark rate Suffolk County Community College and Brookhaven National Lab Lab Setup • Dark box set up to hold four Photomultiplier tubes simultaneously and output signals • Three step data collection 1. Discriminator 2. Delay Generator 3. Visual Scalar • Labview collects and files data and Oscilloscope shows signal outputs from PMTs Wiring Discriminator: The PMTs constantly output a signal (Dark current) regardless of whether or not it detected a photon. The discriminator sets a voltage that has to be exceeded for the signal to pass through. Delay Generator: The delay generator receives the input from the discriminator and outputs to the visual scalar. When active, the delay generator allows the signal to pass through, but only for a set period of time. Visual Scalar: The visual scalar receives the output from the delay generator and outputs the number of signals it receives. Dark Box “light tight” testing • The first problem we encountered with the dark box was there was there was a measureable difference in counts when testing with the lights on vs. the lights off. This meant that the box wasn’t completely sealed • We taped any visible weaknesses in the box and added a layer of foam tape between the box and the lid • We tested the modified box at several different voltages with the lights both on and off and the differences were negligible • The data is plotted above, the red line represents the data collected with the lights on and the black line represents the data with the lights off Dark Current • PMTs constantly output a very low signal whether or not the have detected a photon.
    [Show full text]
  • PHYSICS Glossary
    Glossary High School Level PHYSICS Glossary English/Haitian TRANSLATION OF PHYSICS TERMS BASED ON THE COURSEWORK FOR REGENTS EXAMINATIONS IN PHYSICS WORD-FOR-WORD GLOSSARIES ARE USED FOR INSTRUCTION AND TESTING ACCOMMODATIONS FOR ELL/LEP STUDENTS THE STATE EDUCATION DEPARTMENT / THE UNIVERSITY OF THE STATE OF NEW YORK, ALBANY, NY 12234 NYS Language RBERN | English - Haitian PHYSICS Glossary | 2016 1 This Glossary belongs to (Student’s Name) High School / Class / Year __________________________________________________________ __________________________________________________________ __________________________________________________________ NYS Language RBERN | English - Haitian PHYSICS Glossary | 2016 2 Physics Glossary High School Level English / Haitian English Haitian A A aberration aberasyon ability kapasite absence absans absolute scale echèl absoli absolute zero zewo absoli absorption absòpsyon absorption spectrum espèk absòpsyon accelerate akselere acceleration akselerasyon acceleration of gravity akselerasyon pezantè accentuate aksantye, mete aksan sou accompany akonpaye accomplish akonpli, reyalize accordance akòdans, konkòdans account jistifye, eksplike accumulate akimile accuracy egzatitid accurate egzat, presi, fidèl achieve akonpli, reyalize acoustics akoustik action aksyon activity aktivite actual reyèl, vre addition adisyon adhesive adezif adjacent adjasan advantage avantaj NYS Language RBERN | English - Haitian PHYSICS Glossary | 2016 3 English Haitian aerodynamics ayewodinamik air pollution polisyon lè air resistance
    [Show full text]
  • Fluorescent Light-Emitting Diode (LED) Microscopy for Diagnosis of Tuberculosis
    Fluorescent light-emitting diode (LED) microscopy for diagnosis of tuberculosis —Policy statement— March 2010 Contents Abbreviations Executive summary 1. Background 2. Evidence for policy formulation 2.1 Synthesis of evidence 2.2 Management of declarations of interest 3. Summary of results 4. Policy recommendations 5. Intended audience References Abbreviations CI confidence interval GRADE grades of recommendation assessment, development and evaluation LED light-emitting diode STAG-TB Strategic and Technical Advisory Group for Tuberculosis TB tuberculosis WHO World Health Organization Executive summary Conventional light microscopy of Ziehl-Neelsen-stained smears prepared directly from sputum specimens is the most widely available test for diagnosis of tuberculosis (TB) in resource-limited settings. Ziehl-Neelsen microscopy is highly specific, but its sensitivity is variable (20–80%) and is significantly reduced in patients with extrapulmonary TB and in HIV-infected TB patients. Conventional fluorescence microscopy is more sensitive than Ziehl-Neelsen and takes less time, but its use has been limited by the high cost of mercury vapour light sources, the need for regular maintenance and the requirement for a dark room. Light-emitting diodes (LED) have been developed to offer the benefits of fluorescence microscopy without the associated costs. In 2009, the evidence for the efficacy of LED microscopy was assessed by the World Health Organization (WHO), on the basis of standards appropriate for evaluating both the accuracy and the effect of new TB diagnostics on patients and public health. The results showed that the accuracy of LED microscopy was equivalent to that of international reference standards, it was more sensitive than conventional Ziehl-Neelsen microscopy and it had qualitative, operational and cost advantages over both conventional fluorescence and Ziehl- Neelsen microscopy.
    [Show full text]
  • Chemiluminescence Western Blotting Technical Guide and Protocols
    TECH TIP Chemiluminescent substrates Chemiluminescence western blotting technical guide and protocols Introduction Types and considerations of chemiluminescence Western blotting is a powerful and commonly used tool western blotting to identify and quantify a specific protein in a complex HRP is the most popular enzyme used in western mixture. As originally conceived by Towbin et al., the blotting and will be discussed throughout this document technique enables indirect detection of protein samples as our example. The most suitable western blotting immobilized on a nitrocellulose or polyvinylidene fluoride substrates for HRP are luminol-based, and they produce (PVDF) membrane. In a conventional western blot, a chemiluminescent signal. Chemiluminescence is a protein samples are first resolved by sodium dodecyl chemical reaction that produces energy released in the sulfate–polyacrylamide gel electrophoresis (SDS-PAGE) form of light. In the presence of HRP and a peroxide buffer, and then electrophoretically transferred to the membrane. luminol oxidizes and forms an excited-state product that Following a blocking step, the membrane is probed emits light as it decays to the ground state. Light emission with a primary antibody (polyclonal or monoclonal) occurs only during the enzyme–substrate reaction and, that was raised against the antigen in question. After a therefore, once the substrate in proximity to the enzyme is subsequent washing step, the membrane is incubated with exhausted, signal output ceases. In contrast, colorimetric a secondary antibody conjugated to an enzyme that is substrates, such as diaminobenzidine (DAB), produce reactive toward the primary antibody. An enzyme such as precipitate that remains visible on the membrane even alkaline phosphatase (AP) or horseradish peroxidase (HRP) after the reaction has terminated.
    [Show full text]
  • Introduction 1
    1 1 Introduction . ex arte calcinati, et illuminato aeri [ . properly calcinated, and illuminated seu solis radiis, seu fl ammae either by sunlight or fl ames, they conceive fulgoribus expositi, lucem inde sine light from themselves without heat; . ] calore concipiunt in sese; . Licetus, 1640 (about the Bologna stone) 1.1 What Is Luminescence? The word luminescence, which comes from the Latin (lumen = light) was fi rst introduced as luminescenz by the physicist and science historian Eilhardt Wiede- mann in 1888, to describe “ all those phenomena of light which are not solely conditioned by the rise in temperature,” as opposed to incandescence. Lumines- cence is often considered as cold light whereas incandescence is hot light. Luminescence is more precisely defi ned as follows: spontaneous emission of radia- tion from an electronically excited species or from a vibrationally excited species not in thermal equilibrium with its environment. 1) The various types of lumines- cence are classifi ed according to the mode of excitation (see Table 1.1 ). Luminescent compounds can be of very different kinds: • Organic compounds : aromatic hydrocarbons (naphthalene, anthracene, phenan- threne, pyrene, perylene, porphyrins, phtalocyanins, etc.) and derivatives, dyes (fl uorescein, rhodamines, coumarins, oxazines), polyenes, diphenylpolyenes, some amino acids (tryptophan, tyrosine, phenylalanine), etc. + 3 + 3 + • Inorganic compounds : uranyl ion (UO 2 ), lanthanide ions (e.g., Eu , Tb ), doped glasses (e.g., with Nd, Mn, Ce, Sn, Cu, Ag), crystals (ZnS, CdS, ZnSe, CdSe, 3 + GaS, GaP, Al 2 O3 /Cr (ruby)), semiconductor nanocrystals (e.g., CdSe), metal clusters, carbon nanotubes and some fullerenes, etc. 1) Braslavsky , S. et al . ( 2007 ) Glossary of terms used in photochemistry , Pure Appl.
    [Show full text]
  • Characterisation of Silicon Photomultipliers for the Detection of Near Ultraviolet and Visible Light
    Universit`adegli Studi di Trento { Dipartimento di Fisica Fondazione Bruno Kessler { Integrated Radiation and Image Sensors Characterisation of Silicon Photomultipliers for the detection of Near Ultraviolet and Visible light Cycle XXIX G. Zappala' Supervised by: N. Zorzi Abstract Light measurements are widely used in physics experiments and medical ap- plications. It is possible to find many of them in High{Energy Physics, As- trophysics and Astroparticle Physics experiments and in the PET or SPECT medical techniques. Two different types of light detectors are usually used: thermal detectors and photoelectric effect based detectors. Among the first type detectors, the Bolometer is the most widely used and developed. Its in- vention dates back in the nineteenth century. It represents a good choice to detect optical power in far infrared and microwave wavelength regions but it does not have single photon detection capability. It is usually used in the rare events Physics experiments. Among the photoelectric effect based detectors, the Photomultiplier Tube (PMT) is the most important nowadays for the de- tection of low{level light flux. It was invented in the late thirties and it has the single photon detection capability and a good quantum efficiency (QE) in the near{ultraviolet (NUV) and visible regions. Its drawbacks are the high bias voltage requirement, the difficulty to employ it in strong magnetic field environments and its fragility. Other widely used light detectors are the Solid{State detectors, in particular the silicon based ones. They were developed in the last sixty years to become a good alternative to the PMTs. The silicon photodetectors can be divided into three types depending on the operational bias voltage and, as a conse- quence, their internal gain: photodiodes, avalanche photodiodes (APDs) and Geiger{mode detectors, Single Photon Avalanche Diodes (SPADs).
    [Show full text]
  • Chem 257 Lecture for Exp. 8, 2004 1. Exp. 7 Report: to Be Handed in This Week, Along With: • Relevant Notebook Pages • Vial
    Chem 257 Lecture for Exp. 8, 2004 1. Exp. 7 Report: To be handed in this week, along with: • Relevant notebook pages • Vial containing triphenyl carbinol labeled with your notebook code, i.e., JST-I-38a 2. Exp. 8 Quiz. Be prepared for Quiz. 3. Required Reading. Lab Manual 8.1-10. 4. Relevant Material in Wade (5th): Ultraviolet spectroscopy 15-13 (p 666-672), 16-15 p(711-713), 18-5E (p 785-6). Friedel Crafts Alkylation: 17-11 (p 746-748) & p 980. Exp. 8. Fluorescence and Chemiluminescence. Purpose of the experiment: 1. Synthetic Organic Chemistry • Acquaint you with Friedel-Crafts acylation chemistry 2. Physical Organic Chemistry • Introduce you to photophysics • Acquaint you with chemiluminescent reactions 1 Photochemical Terms and Principles. Useful to consider a ground and excited state energy diagram for an organic molecule. Energy Level Diagram ISC S = singlet S T = triplet 1 A = Absorption F = Fluorescence T IC 1 P = Phosphorescence A ISC = Intersystem crossing E F P IC = Internal Conversion ISC Absorption of a photon Emmission of a photon Vibrational energy loss So Singlet State (S) • Spin paired. • Ground state usually a singlet (So). • First excited singlet state = S1 So S1 • Nth excited singlet state = S n ground excited Triplet State (T) • Spin unpaired. • Lowest triplet state is usually an excited state (T1). • Nth excited triplet state = Tn T T Exceptions: 0 1 • Oxygen is a ground state Ground excited triplet! (O2) 2 Selection rules. • Spin allowed transitions do not involve a change in spin state (Sn → Sm, Tn → Tm). • Thus ground singlet states are most easily excited to their first excited singlet states (So → S1).
    [Show full text]
  • Measuring Peroxyoxalate Chemiluminescence Using a Spectrofluorophotometer No.A493
    LAAN-A-RF-E003 Application Spectrophotometric Analysis News Measuring Peroxyoxalate Chemiluminescence Using a Spectrofluorophotometer No.A493 Chemiluminescence is a phenomenon where molecules n Fluorescent Dyes Used in Glow Sticks are excited by a chemical reaction and then emit light Commercially marketed glow sticks are shown in Fig. 2. energy as they return to ground state. Chemiluminescence The oxalate ester and fluorescent dye solution are placed based on using oxalate esters features high-emission in a sealed thin-walled glass container and the glass efficiency and long emission time and provides container is placed inside a polyethylene tube together illumination for long periods without any electricity. with hydrogen peroxide solution to which a catalyst is Consequently, it is used for recreational, fishing, and many added. Bending the polyethylene tube breaks the glass other applications where it is commonly called glow sticks. container, which causes both solutions to mix together The following describes the luminescent process of and emit light. peroxyoxalate chemiluminescence and gives an example Examples of the fluorescent dyes used in glow sticks are of using an RF-6000 spectrofluorophotometer to measure shown in Fig. 3. Polycyclic aromatic fluorescent dyes are the emission spectra of glow sticks. used, which emit different colors based on the wavelength of light emitted when the fluorescent dyes change from excited to ground state. n Luminescent Process of Peroxyoxalate Chemiluminescence Peroxyoxalate chemiluminescence is caused by a chemical O RO O reaction between an oxalate ester and hydrogen peroxide O C within a fluorescent dye solution. As shown in Fig. 1, the C C + H2O2 2ROH + O C oxalate ester is oxidized by hydrogen peroxide to produce O OR O ROH and 1,2-dioxetanedione.
    [Show full text]
  • Biofluorescence
    Things That Glow In The Dark Classroom Activities That Explore Spectra and Fluorescence Linda Shore [email protected] “Hot Topics: Research Revelations from the Biotech Revolution” Saturday, April 19, 2008 Caltech-Exploratorium Learning Lab (CELL) Workshop Special Guest: Dr. Rusty Lansford, Senior Scientist and Instructor, Caltech Contents Exploring Spectra – Using a spectrascope to examine many different kinds of common continuous, emission, and absorption spectra. Luminescence – A complete description of many different examples of luminescence in the natural and engineered world. Exploratorium Teacher Institute Page 1 © 2008 Exploratorium, all rights reserved Exploring Spectra (by Paul Doherty and Linda Shore) Using a spectrometer The project Star spectrometer can be used to look at the spectra of many different sources. It is available from Learning Technologies, for under $20. Learning Technologies, Inc., 59 Walden St., Cambridge, MA 02140 You can also build your own spectroscope. http://www.exo.net/~pauld/activities/CDspectrometer/cdspectrometer.html Incandescent light An incandescent light has a continuous spectrum with all visible colors present. There are no bright lines and no dark lines in the spectrum. This is one of the most important spectra, a blackbody spectrum emitted by a hot object. The blackbody spectrum is a function of temperature, cooler objects emit redder light, hotter objects white or even bluish light. Fluorescent light The spectrum of a fluorescent light has bright lines and a continuous spectrum. The bright lines come from mercury gas inside the tube while the continuous spectrum comes from the phosphor coating lining the interior of the tube. Exploratorium Teacher Institute Page 2 © 2008 Exploratorium, all rights reserved CLF Light There is a new kind of fluorescent called a CFL (compact fluorescent lamp).
    [Show full text]