REMOTE TERMINAL UNIT DT-10Tsp

Total Page:16

File Type:pdf, Size:1020Kb

REMOTE TERMINAL UNIT DT-10Tsp Development, Production and Engineering of Industrial Electronics Zagreb REMOTE TERMINAL UNIT DT-10TSp Monitoring and Control Program NU-140015E Application Remote terminal unit DT-10 TSp is a part of the range of number of local terminals, measurement and protection remote terminal units series DT-10TS, custom developed devices (e.g. UST-3, NR-300, IK-5(10,20), MT-30(40), for control complex distribution and industrial substations, TP-10). Besides data acquisition, each local terminal has distribution switchgears 10 (20) kV. Remote terminal its own indication, with display of the monitored values. unit DT-10TSp is used in modular expandable switchgears Local terminals can be located, depending on the plant's for remote monitoring and control of complex switchgear. demands, in low voltage, medium voltage or remote part The monitoring and control functions can be extended of the plant (separate cabinet) and connected together by with functions of earth and short-circuit fault indication, optical or RS485 communication. Figure 1. shows the measurement, protection, automation, registration and Remote terminal unit DT-10TSp for monitoring and analysis of power quality and alarming. Info terminal IT-3, control grid connection of renewable energy source. The as a central unit in the system, ensures dynamic display of system includes remote monitoring, control, fault the plant’s state on the graphic LCD display and allows indication and protection. remote and local control of the switchgear. Switchgear As the Remote Terminal Unit is a distributed system, and control can be performed remotely from remote control each local terminal represents an autonomous unit (own center (radio link, Ethernet connection, GPRS or optical microprocessor, own indications-display, own power connection). Depending on the plant's complexity, besides supply), Remote Terminal Unit meets the most demanding Info terminal IT-3, Remote Terminal Unit contains various reliability and availability specifications. RTU DT-10TSp CABINET 14.07.10 20:15 REMOTE TERMINAL UNIT DT-10TSp LOCAL REMOTE COM1 COM2 ETH1 ETH2 RUN TIME SYNC TERMINAL POLJA TP-10 1NADZAŠSTTIRUTA JNI>NA 9ADZAŠSTTIRUTA JNIoA 1 2NADZAŠSTTIRUTA JNI>A 10ZAŠPRTIEOTA S. ODNAP. Uo NADNAPONSKA 0 3ZAŠTITA U> 1 NADNAPONSKA 4ZAŠTITA U> 12RAD NA MREŽI PODNAPONSKA IZOLIRANI POGON 5ZAŠTITA U< 13 6PODNAPONSKA 14IZVAN POGONA ZAŠTITA u< 7NADZAŠFRTIEKVTAENTNA 15 E 8POZAŠDFRTIEKVTAENTNA 16 LOKALNONL APAJANJE PRIHV. RESET C DALJINSKID KVAR TEST ALARMSIRENE RS 485 (F.O.) D GPRS network L MT-40 AM-16 TP-10 UST-3 11121231341451561678C1C2 910 ALARM MONITOR AM-16 TERMINAL POLJA TP-10 1 AUXILIARY VOLTAG E 48V DC OFF 9 T RIP COIL OF F =1SO- 2 NAD STRU JNA NAD STRU JNA 1 1 ZAŠTITA I> 9 ZAŠTITA Io HV F USE OFF =1SO- 1 SYNCHRONIZING RELAY FAILED MJERNI TERMINAL MT-40 NAD STRU JNA ZAŠTITA O D 2 10 2 ZAŠTITA I> > 10 PRE OST. NA P. U o MC B VOLTAG E OF F =1 SO-1 BUSBAR MCB 48 V DC OFF NAD NAPO NSKA 3 11 0 3 ZAŠTITA U> 11 I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 I12 I13 I14 I15 I16 NAD NAPO NSKA 4 PROT ECT ION FAIL ED 12 BUSBAR SUPERVISION FAI LURE 4 ZAŠTITA U>> 12 RAD NA MR EŽI PO DNAP ONS KA PROT ECT ION OFF BUSBAR PROTECTIO N ZONE "A" 5 13 IZOL IRAN I PO GO N PROG 5 13 ZAŠTITA U< PO DNAP ONS KA UST-3 IZVAN POG ONA 6 MC B VOLTAG E OF F = 1SO-3 14 BUSBAR PROTECTIO N ZONE "B" 6 ZAŠTITA u<< 14 NAD FREKVE NTNA HV F USE OFF =1SO- 3 STAR POINT TR. PROTECTION 7 ZAŠTITA 15 7 15 FAI LE D O1 O2 O3 O4 O5 O6 O7 O8 A1 A2 COMM ON E PO DFREK VENTNA STAR POINT TR. PROTECTION 8 ZAŠTITA 16 8 SYNCHRONIZING RELAY FAILED 16 OF F LOKA LNO NAPA JAN JE SY S LA MP TE ST AL AR M L TE ST PR I H V. RESET ON FA IL C DAL J INSKID KVAR ALA R M SI R E NE Internet T 1718 19 20 21 22 23 24C3 A1 A2 A2 B2 +,L -,N VPN Q1Q1 Q1 Q1 Q1 Q0 Q31 Q31 STATUS WAN SCADA COM 1 WAN KONCENTRATOR MOBILNE MREŽE USB COMPACT FLASH SCADA KM2M 0 R1 R2 COM Q8 Is I>I>>IE 14 A 1,5 IS 20 IS 0,4 IS RESET PRORADA t>t>>tE ZAŠTI TE V-INV 15 s 40 m s 6 s IsI>I>>It>t>>E t E MT-DIALOG 2 PQ VISION MT-DIALOG 2 IPQS BAZA NR-300 PODATAKA MT-DIALOG 2 EXPERT ITK-200 SWITCHGEAR 10(20) / 0,4 kV EN50160 IEC 61000-4-30 Figure 1. Remote Terminal Unit DT-10TSp for monitoring and control grid connection of renewable energy source Main features - multiprocessor distributed system - communication protocol MODBUS RTU (TCP), IEC 870-5-101(104), IEC 61850 - plant's size and distribution of equipment defines the number and the disposition of the local terminals - data polling and event driven communication with the control center - the system can be easily expanded - self-test and availability indication of each local terminal - optical or RS 485 communication link between Info and central unit Terminal IT-3 and local terminals - local indication of the plant states and measuring values - communication between the remote control center and (alphanumeric or graphic LCD display and LED Remote Terminal Unit via different media (radio link, segments) Ethernet, GPRS, optical line) - own power supply of every local terminal (optional - event logging with 1ms time resolution redundant power supply) Functional Description Remote Terminal Unit DT-10TSp (Fig. 2) is a Fault indicator IK-5(10,20) is used for earth fault and short multiprocessor distributed system. Basic system circuit fault indication. components are: Info terminal, local terminals, power Power supply unit provides an uninterruptible power supply unit and communication unit. Local terminals used supply for the Remote Terminal Unit even in case of the in DT-10TSp are: Monitoring and Control Terminal UST- main power supply failure. 3, Measuring Terminals series MT, Fault indicator IK, Info Terminal IT-3 is a multiprocessor device equipped Alarm Monitor AM, protection relay NR and Feeder with touch screen LCD. IT-3 is connected via RS 485 or Terminal TP-10. optical link with local terminals. Graphic LCD dynamically Monitoring and control terminal UST-3 is used for remote displays the complete plant’s state and the communication control and indication of the status of switching devices in state. It is possible to configure additional local alarming expandable switchgear. for the most important signals on the LCD (12 channels). Measuring terminal series MT is used for measurement and Software IT DIALOG is intended for local and remote registration of electric quantities in the low voltage and monitoring and control of complex switchgears. The medium voltage part of the switchgear and power quality software provides measurement and registration monitoring (EN 50160, IEC 61000-4-30). functions for power system quantities and power quality Alarm monitors series AM are used for continuous analysis. monitoring of the alarm contacts in the switchgear. The It is possible to select different communication units plant size defines the number and the size of Alarm (radio-modem, Ethernet switch, GPRS, optical link etc.) Monitors. depending on the type of communication medium between Protection relay NR-300 is used for power transformers the control center and Remote Terminal Unit. over current protection. RMU Q1Q1 Q1 Q1 Q1 Q0 Q31 Q31 Q8 IK-5IK-5 IK-5 NR-300 F.O. 230V AC VF UST-3 AM-16 MT-40 TP-10 F2 48V DC RS 485 (F.O.) F3 F4 F5 F6 FN ETHERNET SDI F1 862 P15 BAT MV switchgear apparatus REMOTE TERMINAL UNIT DT-10TSp power supply Figure 2. Remote monitoring and control in MV switchgear 10(20)/0,4kV Technical specifications System architecture: ........................... multiprocessor distributed system Control center communication: .................................. radio link, telephone line, GPRS, optical link, Ethernet Communication among Info Terminal and local terminals: .... RS 485 or F.O. Communication protocols with control center: ............................. MODBUS RTU(TCP), IEC 60870-5-101(104), IEC 61850 Power supply: ...................................... each local terminal and Info Terminal has its own power supply (AC or DC) - double power supply is optional Operation temperature: ...................... standard 0oC...+50oC extended -20oC...+60oC Dimensions: ........................................ for TS 10(20)/0.4kV typically 500x500x210 mm System components: Info terminal ..................................... IT-3 ............................. multiprocessor unit for communication between local terminals and control center (HMI) Monitoring and Control Terminal UST-3 .......................... monitoring, control, signaling Feeder Terminal TP-10 .......................... measurement, monitoring, control, feeder protection Measuring terminal MT-10SQ .................... power values measurement and analysis: 3x phase voltage (RMS), 3x line voltage (RMS), 3x phase current (RMS), MD currents, current histogram, current daily diagram, power (P, Q, S), power factor (cos ), energy (active and reactive), frequency Measuring terminal MT-30(40) ................... power quality analysis, EN 50160, IEC 61000-4-30 class S, class A Overcurrent relay NR-100(300) ............... transformer overcurrent protection Sensor Conditioning Unit PP-10 ........................... non-conventional voltage transformer Alarm monitor AM-8(16) .................... state signaling by means of 8(16) LED components Detailed technical specifications can be found in the leaflets of separate devices. Development, Production and Engineering of Industrial Electronics 10020 Zagreb, Froudeova 56, tel/fax +385 1 6520 688 .
Recommended publications
  • 8130 Remote Terminal Unit
    8130 Remote Terminal Unit Collect and transmit data from multiple storage tanks to a central system or host using a single tank gauge interface for inventory, alarm and control. Highlights •Easily expandable through the use of plug‐in interface modules ‐ reduces cost by integrating all analog, digital and serial data inputs and outputs •Multiple host ports ‐ adapts to your needs and redundancy requirements • Supports multiple tank gauge protocols ‐ connect your existing equipment at less cost • Digital and analog I/O connectivity ‐ allows simple tank farm alarm integration •Fully compatible with FuelsManager ‐ tank inventory management made easy • 8130 RTU and gauge configuration data can be exported to other applications, such as Microsoft Excel® or Access® ‐ document all tank gauge equipment Host Communication •Remote configuration of your tank gauges ‐ means less on‐tank The 8130 RTU connects to most types of sensors or actuators on activities, resulting in less personnel risk your site, and to PLCs and DCS computers. It combines with FuelsManager software to provide an extremely cost efficient and FuelsManager® reliable tank inventory system. It also provides fully redundant host ports and is compatible with a variety of other host systems through the industry standard MODBUS™ protocol. Configuration and Programming Remote programming can be accomplished from the host or locally Network using a PC with the Windows‐based configuration program Communications Field ViewRTU. This tool simplifies configuration and diagnostics, Instruments
    [Show full text]
  • Remote Terminal Unit ENCS-3M
    Remote terminal unit ENCS-3m Manual ENCS.403500.001. Rev 3.2016 Table of contents Table of contents Introduction .................................................................................................. 3 Glossary .................................................................................................... 4 1 General information .......................................................................... 5 2 Design, dimension, naming convention ..................................................... 6 3 Features ......................................................................................... 8 3.1 Device poll and sync time ............................................................. 8 3.2 Telecontrol .............................................................................. 8 3.3 Spontaneous transmission ............................................................. 8 3.4 Cyclic transmission ..................................................................... 8 3.5 Background scan ........................................................................ 8 3.6 IEC 60870-5-101–2006 and IEC 60870-5-104-2004 support ........................ 8 3.7 GOOSE (IEC 61850 8-1) ................................................................. 9 3.8 Configuration ............................................................................ 9 4 Specification .................................................................................. 10 4.1 Interfaces .............................................................................
    [Show full text]
  • Remote Terminal Unit
    MITSUBISHI ELECTRIC ME-RTU User´s Manual Remote Terminal Unit Art. no.: 278247 30.10.2019 INDUSTRIAL AUTOMATION Version B MITSUBISHI ELECTRIC Version check About this Manual The texts, illustrations, diagrams and examples in this manual are provided for information purposes only. They are intended as aids to help explain the installation, operation, programming. If you have any questions about the installation and operation of any of the products described in this manual please contact your local sales office or distributor (see back cover). You can find the latest information and answers to frequently asked questions on our website at https://eu3a.mitsubishielectric.com. MITSUBISHI ELECTRIC EUROPE B.V. reserves the right to make changes to this manual or the technical specifications of its products at any time without notice. User’s Manual Remote Terminal Unit ME-RTU Art. no.: 278247 Version Changes / Additions / Corrections A 07/2014 pdp First edition B 07/2019 pdp Compliant with FW version 3.00 IEC 60870-5-104 Master, IEC 61850 Client added BO AV info added IEC 60870-5-101/104 device profile updated IEC 60870-5-104 Master status BFM fixed Fuse specifications added Safety Guidelines For use by qualified staff only This manual is only intended for use by properly trained and qualified electrical technicians who are fully acquainted with the relevant automation technology safety standards. All work with the hard- ware described, including system design, installation, configuration, maintenance, service and test- ing of the equipment, may only be performed by trained electrical technicians with approved qual- ifications who are fully acquainted with all the applicable automation technology safety standards and regulations.
    [Show full text]
  • The Scada Review: System Components, Architecture, Protocols and Future Security Trends
    American Journal of Applied Sciences 11 (8): 1418-1425, 2014 ISSN: 1546-9239 © 2014 A. Shahzad et al ., This open access article is distributed under a Creative Commons Attribution (CC-BY) 3.0 license doi:10.3844/ajassp.2014.1418.1425 Published Online 11 (8) 2014 (http://www.thescipub.com/ajas.toc) THE SCADA REVIEW: SYSTEM COMPONENTS, ARCHITECTURE, PROTOCOLS AND FUTURE SECURITY TRENDS 1 1 1 2 Shahzad, A., S. Musa, A. Aborujilah and M. Irfan 1Malaysian Institute of Information Technology (MIIT), University Kuala Lumpur, Malaysia 2Windfield College, Kuala Lumpur, Malaysia Received 2014-01-15; Revised 2014-05-13; Accepted 2014-05-27 ABSTRACT The Supervisory Control and Data Acquisition (SCADA) system has prominent place and play important roles within real time industrial communication included “electric stations, oil stations and water purification plants”. In this study; the SCADA System main components, architecture and important protocols, which have been used in SCADA message transmission are reviewed. After review, the current research changes the direction (Section: Future Work) to the security of SCADA system and the existing methods or security methods that have been deployed within the SCADA system. This review also gives directions to secure SCADA network communication. Keywords: Supervisory Control and Data Acquisition (SCADA) System, Protocols, Security Trends 1. INTRODUCTION to Master Terminal Station (MTU) for monitoring and controlling the entire SCADA system. Usually, SCADA 1.1. SCADA System Components system is divided into five main components/parts (illustrated in Fig. 1) “included Master Terminal Unit The SCADA system is based on hardware included (MTU), Remote Terminal Unit (RTU) and Human “Master Terminal Unit (MTU), Remote Terminal Units Machine Interface (HMI) historian” and SCADA (RTUs)” or/and actuators and sensors and software communication media or link (Stouffer and Kent, 2006; included Human Machine Interface (HMI) or other user Musa et al ., 2013b).
    [Show full text]
  • SCADA for Relay Technicians
    BONNEVILLE POWER ADMINISTRATION SCADA for Relay Technicians Tracy Kealy – BPA 2019 Hands-On Relay School Pullman, WA 1 BONNEVILLE POWER ADMINISTRATION Objectives • Overview of EMS and SCADA • Overview of DNP3 • Testing and troubleshooting DNP3 communications between IEDs and SCADA RTUs 2 2 BONNEVILLE POWER ADMINISTRATION EMS • Energy Management Systems (EMS) are computer applications used to monitor, control, and optimize performance of the generation and transmission system. Dispatcher / System Operator 3 EMS includes tools that: • Monitor current system conditions • Match generation to load • Allow dispatchers to control substation equipment • Allow dispatchers to perform “what if” scenarios • Alert dispatchers of abnormal system conditions 3 BONNEVILLE POWER ADMINISTRATION SCADA Supervisory Control And SCADA Data Acquisition 4 One application of EMS is SCADA. SCADA allows dispatchers to monitor current system conditions and control substation equipment remotely. 4 3/11/2019 BONNEVILLE POWER ADMINISTRATION SCADA – Supervisory Control And Data Acquisition Substation Control Center (Dispatch) Supervisory Control SCADA Master Data Acquisition ALARM PCB 13:45.127 RTU Remote Terminal Unit ALARM PCB 13:45.127 5 *Animated Slide. Periodically, the “SCADA master” at the control center will query or poll each of the RTUs for measurements (i.e. Bus voltage, breaker status, power flow) to gather system condition information. This is the Data Acquisition part of SCADA. Locally at the station, there may also be an HMI to provide indications at the station. When a dispatcher wants to remotely control a piece of substation equipment (i.e. trip a breaker, raise a tap changer, etc.), they can send a command through the SCADA master to an RTU.
    [Show full text]
  • PROTOCOL Translator DNP3 User Manual
    PROTOCOL Translator DNP3 User Manual Protocol Translator DNP3 User Manual Page 2 of 42 MultiTrode_MTT_DNP3_Manual_v1-0-9_R02.doc Protocol Translator DNP3 User Manual Revision Table Rev Detail of Change 01 Initial issue 02 Format and style update. This document is in support of the Multitrode Translator. Version 1.0.9 Revision 02 This document is valid for MultiTrode Translator firmware version 1.09 or newer. MultiTrode reserves the right to update this document without notification. MULTITRODE® and MULTISMART® are registered trademarks of MultiTrode Pty Ltd in Australia, USA and many countries worldwide. PUMPVIEW® is a registered trademark of MultiTrode Pty Ltd in Australia. Design registration is pending for the MultiSmart Pump Controller Remote and Base Modules in Australia, USA and many countries worldwide. Patents pending in Australia, USA and many countries worldwide. ©2007 MultiTrode Pty Ltd. This publication is protected by copyright. No part of this publication may be reproduced by any process, electronic or otherwise, without the express written permission of MultiTrode Pty Ltd. Although every attempt has been made to ensure the correctness of the information contained herein, no liability is accepted by Multitrode or its staff for any errata contained. MultiTrode_MTT_DNP3_Manual_v1-0-9_R02.doc Page 3 of 42 Protocol Translator DNP3 User Manual Page 4 of 42 MultiTrode_MTT_DNP3_Manual_v1-0-9_R02.doc Protocol Translator DNP3 User Manual Contents 1 Introduction ..............................................................................................................7
    [Show full text]
  • Security Hardened Remote Terminal Units for SCADA Networks
    University of Louisville ThinkIR: The University of Louisville's Institutional Repository Electronic Theses and Dissertations 5-2008 Security hardened remote terminal units for SCADA networks. Jeff Hieb University of Louisville Follow this and additional works at: https://ir.library.louisville.edu/etd Recommended Citation Hieb, Jeff, "Security hardened remote terminal units for SCADA networks." (2008). Electronic Theses and Dissertations. Paper 615. https://doi.org/10.18297/etd/615 This Master's Thesis is brought to you for free and open access by ThinkIR: The University of Louisville's Institutional Repository. It has been accepted for inclusion in Electronic Theses and Dissertations by an authorized administrator of ThinkIR: The University of Louisville's Institutional Repository. This title appears here courtesy of the author, who has retained all other copyrights. For more information, please contact [email protected]. SECURITY HARDENED REMOTE TERMINAL UNITS FOR SCADA NETWORKS By Jeffrey Lloyd Hieb B.S., Furman University, 1992 B.A., Furman University, 1992 M.S., University of Louisville, 2004 A Dissertation Submitted to the Faculty of the Graduate School of the University of Louisville in Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy Department of Computer Science and Computer Engineering J. B. Speed School of Engineering University of Louisville Louisville, Kentucky May 2008 SECURITY HARDENED REMOTE TERMINAL UNITS FOR SCADA NETWORKS By Jeffrey Lloyd Hieb B.S., Furman University, 1992 B.A., Furman University, 1992 M.S., University of Louisville, 2004 A Dissertation Approved on February 26, 2008 By the following Dissertation Committee members Dr. James H. Graham, Dissertation Director Dr.
    [Show full text]
  • Remote Terminal Unit (RTU)
    Eaton Smart Grid solutions for Ring Main Units Remote Terminal Unit (RTU) The Remote Terminal Unit is a device for acquiring, processing, storing and transmitting information Measurement and control on the medium voltage (MV) and transformer side of a Ring Main Unit (RMU) will reduce the outage time and the possibility of outages. In more advanced applications with directional fault indicators and some logic, outages can be solved within seconds after a fault has occurred. After an anomaly has been detected, the RMU will automatically contact the operating center where the information is shown on a SCADA system and where actions can be taken to solve or prevent problems. A RTU can also measure Current and Voltage at the low voltage (LV) side of the RMU. By comparing these figures with the information from smart meters, deviations can be detected easily which indicates either a fault or an illegal power tap. Benefits of using RTU for Utilities Nowadays, utility companies are mainly looking for automated Eaton developed this Remote Terminal Unit (RTU) medium voltage solutions due to the focus of these two goals: especially focusing on Ring Main Units applications • Improve standard IEEE reliability indices: for the medium voltage grid. n SAIDI: System Average Interruption Duration Index (SAIDI) The RTU enables utilities to reduce the duration of power n SAIFI: System Average Interruption Frequency Index (SAIFI) outages. This reduces the downtime in three ways: • Overview of the grid (Voltage, Current, Direction, other • Customers do not
    [Show full text]
  • DNP 3.0, IEC 870-5-101 & Modbus
    M.Tech. Credit Seminar Report, Electronics Systems Group, EE Dept, IIT Bombay, submitted November 03 Comparison of protocols used in remote monitoring: DNP 3.0, IEC 870-5-101 & Modbus Jay Makhija (03307905) Supervisor: Prof. L.R.Subramanyan Abstract A brief introduction to IEC 870-5-101, DNP 3.0 and Modbus is presented together with the explanation of functionalities provided by these protocols. Comparison between these protocols, considering various aspects like architecture, functions performed by individual layers, device addressing and configuration parameter s etc is done. Here objective is to compare protocols not to conclude which one is better. Selection of protocol depends mainly on application, specific requirements and functions to be carried out, which protocol to be used for what purpose is discussed. 1. Introduction In a SCADA system, the RTU accepts commands to operate control points, set analog output levels, and provide responses, it sends status, analog, and accumulator data to the SCADA master station. The data representations sent are not identified in any fashion other than by absolute addressing. The addressing is designed to correlate with a database contained in the SCADA master station, and the RTU has no knowledge of which unique parameters it is monitoring in the real world. It simply monitors certain points and stores the information in a local addressing scheme. Figure 1 illustrates the data and control flow between a master station and one or more RTUs. SUPERVISORY CONTROLS TRIP/CLOSE C RAISE/LOWER O OPEN/CLOSE C M I STOP/START O COMPUTER M N SETPOINT/VALUES M I SYSTEM U T PARAMETER DOWNLOAD M N REMOTE N E CONTROL PROGRAMS* U T TERMINAL C R DATABASE CHANGES* N E UNIT A F ALARM PARAMETERS* C R T A A F I C T A O E STANDARD TIME SIGNAL I C N O E ANALOG DATA N ACCUMALATOR DATA DIGITAL DATA STATUS ALARM SEQUENCE OF EVENTS DIAGNOSTIC RESULTS ABNORMALITIES * Optional field MASTER COMMUNICATION FIELD STATION SYSTEM SITE(S) Figure 1 Master/RTU functional data/control flow [ref.
    [Show full text]
  • Intelligent Remote Terminal Unit (Irtu) in the Iot Era
    November 2015 Intelligent Remote Terminal Unit (iRTU) in the IoT Era Author: Advantech E-mail: [email protected] www.advantech.com . Introduction . The power of the Internet of Things. (IoT) is enabled by the implementation of intelligent electronic devices and sensors on communication networks with real-time data exchange and control functionality between. the field and a control center. It allows utilities to have better visibility into the system conditions anywhere and at any time utilizing advanced automated applications that improve system reliability, efficiency, and customer service. Intelligent electronic devices include - inter alia - all kinds of Remote Terminal Units (RTUs), which are generally defined as a microprocessor-controlled electronic devices that interface objects in the physical world to a distributed control or SCADA system by transmitting telemetry data. Many manufactures of automation instrumentation including Advantech offers RTUs of different size and capabilities to fit into any custom applications. The processing power of RTU devises ranges from small 8 bit processors with minimal memory to larger sophisticated RTUs capable of managing hundreds of I/O points. RTU aspects and technical details in the era of IoT are discussed in the following. This includes positioning of RTUs in the manifold “landscape” of automation equipment as well as Advantech´s respective hard- and software offerings. RTUs in the “landscape” of automation equipment There is a continuous discussion in the automation market about the differences between DCS (Distributed Control Systems), PLC (Programmable Logic Controller), SCADA (Supervisory Control And Data Acquisition), RTU (Remote Terminal Unit) and PAC (Programmable Automation Controller). One basic distinction can be seen already from the expanded acronyms: SCADA includes Data Acquisition in addition to Control, while DCS and PLC contains only Control; and RTU includes Remote.
    [Show full text]
  • Remote Terminal Unit (RTU - A200)
    Delivering Value through Innovation... Remote Terminal Unit (RTU - A200) AMI with more than six years of expertise in Power System Protection has developed state of the art of the Automation Solutions. The whole family of AMI’s Remote Terminal Unit (RTU) and Feeder Remote Terminal Unit (FRTU) covers a broad spectrum of use with products of different sizes of various applications. The A200 is specifically architectured for use with medium to large numbers of data points, and is well -suited across a range. A200 Remote Terminal Unit (RTU), the building block of AMI Substation Automation System is designed to meet the present day utility and industry demands. The RTU is built on internationally well proven hardware and software platform gives the necessary ruggedness and the RTOS (Real-Time operating System) provides the multi-tasting and Real-Time data handling capability. APPLICATION HARDWARE • Gateway for communication between lEDs and Master Major Hardware Components : Station • Central Processing Unit (CPU) • Data concentrator for storing data from lEDs and • Digital Input Module (DI) transferring it to Master Station • Digital Output Module (DO) • Automation unit for building soft logic • Analog Input Module (AI) • Station level RTU for hardwired inputs • Power Supply Module (PSM) FEATURES 32-bit High Performance Industrial Grade CPU Core Supports IEC 61131 PLC Programming Language Standards operating at 400 MHz Frequency Digital Inputs: Multiples of 16 channels optimally isolated from Memory: Onboard 64 MB SDRAM and 256 MB Flash
    [Show full text]
  • Communication Requirements for a Hybrid VSC Based HVDC/AC Transmission Networks State Estimation
    energies Article Communication Requirements for a Hybrid VSC Based HVDC/AC Transmission Networks State Estimation Motaz Ayiad 1,2,*,† , Emily Maggioli 2, Helder Leite 2 and Hugo Martins 1 1 Efacec Automation, Grid Management Division, 4471-907 Porto, Portugal; [email protected] 2 Faculty of Engineering (FEUP), University of Porto, 4200-465 Porto, Portugal; [email protected] (E.M.); [email protected] (H.L.) * Correspondence: [email protected] † Current address: Via de Francisco Sá Carneiro Apartado 3078, 4471-907 Moreira da Maia, Porto, Portugal. Abstract: The communication infrastructure of the modern Supervisory, Control and Data Acquisition (SCADA) system continues to enlarge, as hybrid High Voltage Direct Current (HVDC)/Alternating Current (AC) networks emerge. A centralized SCADA faces challenges to meet the time requirements of the two different power networks topologies, such as employing the SCADA toolboxes for both grids. This paper presents the modern communication infrastructure and the time requirements of a centralized SCADA for hybrid HVDC/AC network. In addition, a case study of a complete cycle for a unified Weighted Least Squares (WLS) state estimation is tested on a hybrid HVDC/AC transmission network, based on Voltage Source Converter (VSC). The cycle estimates the elapsed times from the sensors up to the SCADA side, including the data acquisition and the WLS processing times. The case study is carried out on the Cigre B4 DC test case network with 43 virtual Remote Terminal Unit (RTU)s installed and 10 data concentrators, all connected through a fiber-based communication network. It is concluded that the time requirements can be fulfilled for a hybrid HVDC/AC network.
    [Show full text]