Powered and Bypass

THUMD500APA00B - Fan Powered THUMD300ABA00B - Large Bypass Humidifier THUMD200ABM00B - Small Bypass Humidifier

THUMD500A THUMD200A/300A

PUB. NO. 22-1821-02 © 2009 Trane Features and Benefits

Features: THUMD500A Features: THUMD200,300A • Flow Through Fan Powered Humidifier • THUMD300A Bypass delivers up to 17 Gallons per day • High Performance Humidifier Delivers up to 18 Gallons • THUMD200A delivers up to 12 Gallons per day. per Day • THUMD300A Automatic Humidifier Control and O.D. • Humidifies an Average Home of up to 2100 SqFt Sensor for up to 50% more • Automatic Humidifier Control with O.D. Sensor for up to • THUMD200A Manual Humidifier Control 50% more Humidity • UV Resistant Cabinet and Scale Control Insert • Front Cover Access for easy replacement of humidifier • Front Cover Access for easy replacement of humidifier pad. pad. • Aluminum Humidifier Pad Treated with Ceramic Clay • Aluminum Humidifier Pad Treated with Ceramic Clay for Enhanced Pad Performance for Enhanced Pad Performance • Reliable Brass Solenoid w/Stainless Steel Valve • Reliable Brass Solenoid Valve w/Stainless Steel Valve Seat Seat • UV Resistant Cabinet and Scale Control Insert • Field Convertible Connection, Left or Right Side • Saddle Valve • Built in Summer / Winter • Polyslate Gray Housing matches Cabinet Color • Saddle Valve • 120V Power Line Cord • Polyslate Gray Housing matches Furnace Cabinet Color • 24/120 V Transformer

Optional Equipment

OPTIONAL EQUIPMENT FOR HUMIDIFIERS Large Humidifier Pad 13”x10” ...... BAYPAD02A1310A4 [] Small Humidifier Pad 9-7/8”x9-5/8” ...... BAYPAD01A1010A4 [] Automatic Humidifier Control ...... TCONTH01AAUTOA[ ] Current Sensing Relay ...... BAYRLY10ASENSA [ ] Adapter Plate (Duct Mount) ...... BAYPLT01AMHCOA [ ] 4 Packaged 10 per carton.

2 Pub. No. 22-1821-02 General Data

MODEL THUMD500APA00B THUMD300ABA00B THUMD200ABA00B RATED /PH/HZ 120/1/60 24/1/60 24/1/60 RATE GALLONS / DAY 18 17 12 Water Feed Rate (Gal/hr) 6 6 3 AIRFLOW Fan Bypass Bypass Water Flow Drain Drain Drain 120 V LINE CORD Yes N/A N/A Min. Brch. Cir. Ampacity 3 10 N/A N/A LOW VOLTAGE 24V 60 Hz Amps .1 0.50 0.50 VA(Max) 2.4 12 12 Watts 2.4 6 6 CONNECTIONS Water (Potable) inlet 1/4-in Copper Tubing 1/4-in Copper Tubing 1/4-in Copper Tubing Water Drain 1/2-in hose 1/2-in plastic hose 1/2-in plastic hose Bypass Opening (Duct) N/A 6 in round 6 in round DIMENSIONS Crated (in.) 18.4 x 17.2 x 13.5 18.7 x 15.0 x 11.5 15.8 x 15.2 x 11.5 Uncrated (in.) H x W x D 18.3 x 15.8 x 11.0 17.8 x 14.1 x 9.4 14.9 x 13.8 x 9.4 Duct Opening W x H 14-3/16 x 14-7/8 12.5 x 9.75 9-1/2 x 9-3/8 WEIGHT Shipping (lbs.) / Net (lbs.) 20 / 17 15 / 12 14 / 11 STANDARD EQUIPMENT (included) Automatic Humidifier Control 24 V Automatic Humidifier Control 24 V Manual Humidifier Control 24 V Transformer N/A 120V / 24V 12 VA 120V / 24V 12 VA Water Valve Solenoid, 24 VAC Solenoid, 24 VAC Solenoid, 24 VAC Fan Motor 1/70 HP 120 VAC N/A N/A Relay SPST 24 VAC N/A N/A Saddle Valve Included Included Included Damper (Summer / Winter) N/A Included Included ACCESSORIES ( not included) Humidifier Pad Model No. BAYPAD02A1310A BAYPAD02A1310A BAYPAD01A1010A Size in. 13 x 10 x 1-11/16 13 x 10 x 1-11/16 9-7/8 x 9-5/8 x 1-11/16 Automatic Humidifier Control Included Included TCONTH01AUTOA Current Sensing Relay BAYRLY10ASENSA BAYRLY10ASENSA BAYRLY10ASENSA Duct Plate for Manual Humidifier Control N/A N/A BAYPLT01AMHC0A

Pub. No. 22-1821-02 3 THUMD500APA00B FAN POWERED HUMIDIFIER 15.81 11.00

18.25 15.91

THUMD300ABA00B LARGE BYPASS HUMIDIFIER

17.84 15.5

14.1 9.44 THUMD200ABM00B SMALL BYPASS HUMIDIFIER

SUMMER

WINTER 14.88

12.69 SUMMER

13.81 9.44 4 Pub. No. 22-1821-02 TCONTH01AUTOA AUTOMATIC HUMIDIFIER CONTROL

5.91 1.89

4.22

OPEN PIN OUTDOOR C A A

/ TEMPERATURE V A 4

2 SENSOR

SHUNTS

SHUNT POSITION

FOR OPERATION DURING "HEATING CALL" ONLY FOR OPERATION DURING "HEAT CALL" ONLY

AUTOMATIC CONTROL AUTOMATIC CONTROL WIRING TERMIINALS WIRING TERMIINALS OUTDOOR OUTDOOR TEMPERATURE TEMPERATURE A /A A /A 24 VAC SENSOR 24 VAC SENSOR

FURNACE FURNACE LOW VOLTAGE TERMINALS OUTDOOR OUTDOOR ACCESSORY SENSOR (2 VA MINIMUM) SENSOR TERMINALS B/C 120 VAC 120 VAC 24 VAC 24 VAC "HUM "HUM" W1 TRANSFORMER H N (FURNISHED)

FAN POWERED HUMIDIFIER BYPASS HUMIDIFIER

HUMIDIFIER CORD PLUGGED INTO 120 VAC POWER SOURCE

FOR HUMIDIFIER OPERATION WHEN BLOWER IS ENERGIZED FOR HUMIDIFIER OPERATION WHEN BLOWER IS ENERGIZED

AUTOMATIC CONTROL AUTOMATIC CONTROL WIRING TERMIINALS WIRING TERMIINALS OUTDOOR OUTDOOR 24 VAC A /A TEMPERATURE A /A TEMPERATURE SENSOR 24 VAC SENSOR

OUTDOOR OUTDOOR SENSOR SENSOR 120 VAC 120 VAC "EAC" 120 VAC 24 VAC "EAC" 120 VAC 24 VAC TERMINALS TERMINALS TRANSFORMER ON FURNACE ON FURNACE TRANSFORMER (NOT SUPPPLIED) (FURNISHED)

FAN POWERED HUMIDIFIER BYPASS HUMIDIFIER

HUMIDIFIER CORD PLUGGED INTO 120 VAC POWER SOURCE

Pub. No. 22-1821-02 5 MANUAL HUMIDIFIER CONTROL ( SHIP With THUMD200AB00B)

4.50 2.12

OFF 15

25 2.75

35 45 WHEN OUTSIDE TEMP IS -20 0 +20 % HUMIDITY RESET HUMIDITY T0 15% 25% 35%

(SADDLE) VALVE WATER SUPPLY MANUAL HUMIDIFIER CONTROL

120 VAC 24 VAC TRANSFORMER (FURNISHED) CONNECT DRAIN LINE HERE

THUMD200ABM00B SMALL BYPASS HUMIDIFIER

6 Pub. No. 22-1821-02 SUGGESTED BYPASS HUMIDFIER LOCATIONS

RETURN AIR

OPTIONAL NOT ALL MODELS

SUPPLY AIR

DOWNFLOW FURNACE

Pub. No. 22-1821-02 7 Literature Order Number 22-1821-02 05/09 File Number 22-1821-02 Supersedes 22-1821-01 Date 05/09 Trane 6200 Troup Highway Tyler, TX 75707 SinceTrane has a policy of continuous product and product data improvement, it reserves the right to change www.trane.com design and specifications without notice.