Trane Fan Powered and Bypass Humidifiers

Trane Fan Powered and Bypass Humidifiers

Fan Powered and Bypass Humidifiers THUMD500APA00B - Fan Powered Humidifier THUMD300ABA00B - Large Bypass Humidifier THUMD200ABM00B - Small Bypass Humidifier THUMD500A THUMD200A/300A PUB. NO. 22-1821-02 © 2009 Trane Features and Benefits Features: THUMD500A Features: THUMD200,300A • Flow Through Fan Powered Humidifier • THUMD300A Bypass delivers up to 17 Gallons per day • High Performance Humidifier Delivers up to 18 Gallons • THUMD200A delivers up to 12 Gallons per day. per Day • THUMD300A Automatic Humidifier Control and O.D. • Humidifies an Average Home of up to 2100 SqFt Sensor for up to 50% more Humidity • Automatic Humidifier Control with O.D. Sensor for up to • THUMD200A Manual Humidifier Control 50% more Humidity • UV Resistant Cabinet and Scale Control Insert • Front Cover Access for easy replacement of humidifier • Front Cover Access for easy replacement of humidifier pad. pad. • Aluminum Humidifier Pad Treated with Ceramic Clay • Aluminum Humidifier Pad Treated with Ceramic Clay for Enhanced Pad Performance for Enhanced Pad Performance • Reliable Brass Solenoid Valve w/Stainless Steel Valve • Reliable Brass Solenoid Valve w/Stainless Steel Valve Seat Seat • UV Resistant Cabinet and Scale Control Insert • Field Convertible Duct Connection, Left or Right Side • Saddle Valve • Built in Summer / Winter Damper • Polyslate Gray Housing matches Furnace Cabinet Color • Saddle Valve • 120V Power Line Cord • Polyslate Gray Housing matches Furnace Cabinet Color • 24/120 V Transformer Optional Equipment OPTIONAL EQUIPMENT FOR HUMIDIFIERS Large Humidifier Pad 13”x10” ................................................................................................... BAYPAD02A1310A4 [] Small Humidifier Pad 9-7/8”x9-5/8” ............................................................................................BAYPAD01A1010A4 [] Automatic Humidifier Control ...................................................................................................... TCONTH01AAUTOA[ ] Current Sensing Relay .............................................................................................................. BAYRLY10ASENSA [ ] Adapter Plate (Duct Mount) ...................................................................................................... BAYPLT01AMHCOA [ ] 4 Packaged 10 per carton. 2 Pub. No. 22-1821-02 General Data MODEL THUMD500APA00B THUMD300ABA00B THUMD200ABA00B RATED VOLTS/PH/HZ 120/1/60 24/1/60 24/1/60 RATE GALLONS / DAY 18 17 12 Water Feed Rate (Gal/hr) 6 6 3 AIRFLOW Fan Bypass Bypass Water Flow Drain Drain Drain 120 V LINE CORD Yes N/A N/A Min. Brch. Cir. Ampacity 3 10 N/A N/A LOW VOLTAGE 24V 60 Hz Amps .1 0.50 0.50 VA(Max) 2.4 12 12 Watts 2.4 6 6 CONNECTIONS Water (Potable) inlet 1/4-in Copper Tubing 1/4-in Copper Tubing 1/4-in Copper Tubing Water Drain 1/2-in plastic hose 1/2-in plastic hose 1/2-in plastic hose Bypass Opening (Duct) N/A 6 in round 6 in round DIMENSIONS Crated (in.) 18.4 x 17.2 x 13.5 18.7 x 15.0 x 11.5 15.8 x 15.2 x 11.5 Uncrated (in.) H x W x D 18.3 x 15.8 x 11.0 17.8 x 14.1 x 9.4 14.9 x 13.8 x 9.4 Duct Opening W x H 14-3/16 x 14-7/8 12.5 x 9.75 9-1/2 x 9-3/8 WEIGHT Shipping (lbs.) / Net (lbs.) 20 / 17 15 / 12 14 / 11 STANDARD EQUIPMENT (included) Humidistat Automatic Humidifier Control 24 V Automatic Humidifier Control 24 V Manual Humidifier Control 24 V Transformer N/A 120V / 24V 12 VA 120V / 24V 12 VA Water Valve Solenoid, 24 VAC Solenoid, 24 VAC Solenoid, 24 VAC Fan Motor 1/70 HP 120 VAC N/A N/A Relay SPST 24 VAC N/A N/A Saddle Valve Included Included Included Damper (Summer / Winter) N/A Included Included ACCESSORIES ( not included) Humidifier Pad Model No. BAYPAD02A1310A BAYPAD02A1310A BAYPAD01A1010A Size in. 13 x 10 x 1-11/16 13 x 10 x 1-11/16 9-7/8 x 9-5/8 x 1-11/16 Automatic Humidifier Control Included Included TCONTH01AUTOA Current Sensing Relay BAYRLY10ASENSA BAYRLY10ASENSA BAYRLY10ASENSA Duct Plate for Manual Humidifier Control N/A N/A BAYPLT01AMHC0A Pub. No. 22-1821-02 3 THUMD500APA00B FAN POWERED HUMIDIFIER 15.81 11.00 18.25 15.91 THUMD300ABA00B LARGE BYPASS HUMIDIFIER 17.84 15.5 14.1 9.44 THUMD200ABM00B SMALL BYPASS HUMIDIFIER SUMMER WINTER 14.88 12.69 SUMMER 13.81 9.44 4 Pub. No. 22-1821-02 TCONTH01AUTOA AUTOMATIC HUMIDIFIER CONTROL 5.91 1.89 4.22 OPEN PIN OUTDOOR C A A / TEMPERATURE V A 4 2 SENSOR SHUNTS SHUNT POSITION FOR OPERATION DURING "HEATING CALL" ONLY FOR OPERATION DURING "HEAT CALL" ONLY AUTOMATIC CONTROL AUTOMATIC CONTROL WIRING TERMIINALS WIRING TERMIINALS OUTDOOR OUTDOOR TEMPERATURE TEMPERATURE A /A A /A 24 VAC SENSOR 24 VAC SENSOR FURNACE FURNACE LOW VOLTAGE TERMINALS OUTDOOR OUTDOOR ACCESSORY SENSOR (2 VA MINIMUM) SENSOR TERMINALS B/C 120 VAC 120 VAC 24 VAC 24 VAC "HUM "HUM" W1 TRANSFORMER H N (FURNISHED) FAN POWERED HUMIDIFIER BYPASS HUMIDIFIER HUMIDIFIER CORD PLUGGED INTO 120 VAC POWER SOURCE FOR HUMIDIFIER OPERATION WHEN BLOWER IS ENERGIZED FOR HUMIDIFIER OPERATION WHEN BLOWER IS ENERGIZED AUTOMATIC CONTROL AUTOMATIC CONTROL WIRING TERMIINALS WIRING TERMIINALS OUTDOOR OUTDOOR 24 VAC A /A TEMPERATURE A /A TEMPERATURE SENSOR 24 VAC SENSOR OUTDOOR OUTDOOR SENSOR SENSOR 120 VAC 120 VAC "EAC" 120 VAC 24 VAC "EAC" 120 VAC 24 VAC TERMINALS TERMINALS TRANSFORMER ON FURNACE ON FURNACE TRANSFORMER (NOT SUPPPLIED) (FURNISHED) FAN POWERED HUMIDIFIER BYPASS HUMIDIFIER HUMIDIFIER CORD PLUGGED INTO 120 VAC POWER SOURCE Pub. No. 22-1821-02 5 MANUAL HUMIDIFIER CONTROL ( SHIP With THUMD200AB00B) 4.50 2.12 OFF 15 25 2.75 35 45 WHEN OUTSIDE TEMP IS -20 0 +20 % HUMIDITY RESET HUMIDITY T0 15% 25% 35% (SADDLE) VALVE WATER SUPPLY MANUAL HUMIDIFIER CONTROL 120 VAC 24 VAC TRANSFORMER (FURNISHED) CONNECT DRAIN LINE HERE THUMD200ABM00B SMALL BYPASS HUMIDIFIER 6 Pub. No. 22-1821-02 SUGGESTED BYPASS HUMIDFIER LOCATIONS RETURN AIR OPTIONAL FLUE NOT ALL MODELS SUPPLY AIR DOWNFLOW FURNACE Pub. No. 22-1821-02 7 Literature Order Number 22-1821-02 05/09 File Number 22-1821-02 Supersedes 22-1821-01 Date 05/09 Trane 6200 Troup Highway Tyler, TX 75707 SinceTrane has a policy of continuous product and product data improvement, it reserves the right to change www.trane.com design and specifications without notice..

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    8 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us