TO CONNECT THE UNIT TO USE THE UNIT

WIRING TO 24 V. BY PASS HUMIDIFIE R Press to select OFF, MANUAL or AUTO mode (if outdoor sensor is connected). OFF mode: The humidifier is turned off. E2 • JUMPER WIRE • MANUAL mode: The E2 will work to maintain the single selected. You can set your desired INTRODUCTION OUTDOOR TEMP. SENSOR humidity level by pressing or . The humidifier will Thank you for selecting the GENERALAire E2 Humidistat. (NOT USED IN MANUAL MODE) turn ON or OFF according to your manual setting. (The A professional technician should install the unit. humidifier will operate when the measured relative humidity falls more than 2% below the set point.) NOTE Please keep this manual handy as you use your Humidity will have to be lowered when weather is new product. It contains practical step-by-step HUMIDIFIER 24V. SOLENOID VALVE colder or if condensation is suspected. instructions, as well as technical specifications and OR 24V. DRUM MOTOR Suggested Setting Outdoor Temperatures warnings you should know about. 727-58 24 V. TRANSFORMER 15% -20˚F -29˚F OR 24 VAC POWER SUPPLY SWITCHED WITH OPERATION 20% -10˚F -23˚C OVERVIEW 25% 0˚F -18C 30% +10˚F -12˚C FRONT VIEW WIRING TO 1137, 1000 POWER HUMIDIFIE R 35% +20˚F - 7˚C 40% +30˚F - 1˚C • AUTO mode: The E2 will automatically raise the humidity as the outdoor temperature increases. This provides the highest possible humidity. The E2 will automatically lower the humidity as temperatures drop. OUTDOOR TEMP. SENSOR This minimizes the risk of condensation on cold (NOT USED IN MANUAL MODE) surfaces like windows. You can adjust the Auto Humidity Index Set Point from 0 (low) to 10 (high) by HUMIDIFIER CONTROL LEADS (YELLOW WIRES) pressing or . The Humidity Index is based on the

24V OUTPUT FROM HUMIDIFIER (RED WIRES) OR outdoor temperature and indoor humidity. The 727-58 24 V. TRANSFORMER SWITCHED WITH FURNACE OR humidifier will switch ON/OFF according to the OR 24 VAC POWER SUPPLY SWITCHED WITH FURNACE. calculated auto humidity index set point. Lower Index settings are for older homes with less insulation and 1. Operation modes WIRING TO DS-20 ELITE STEAM HUMIDIFIE R vapor barriers. Higher Index settings are for newer 2. Moisture is being added into the environment homes with complete vapor barriers, triple pane 3. Humidity / temperature reading GO JUMPER WIRE TAM windows and high R-value insulation. If condensation G occurs lower Index settings 2 points until condensation 4. : Toggle between OFF, MANUAL and AUTO TP OUTDOOR TEMP. SENSOR FUSE TP stops. modes (if outdoor sensor is connected) (NOT USED IN MANUAL MODE) ON GND DR NOTE If the outdoor temperature sensor fails, EV2 5. : Toggle between indoor humidity and indoor / TO STEAM G flashes and the unit will default to MANUAL mode. outdoor temperature displays (if outdoor sensor is HUMIDIFIER EV1 FIELD SUPPLIED • To toggle between indoor / outdoor temperature connected) 2 POLE SINGLE CONTROL EV3 THROW REL AY MODULE G 6. °C / °F: Select temperature unit FAC TORY INS TALLE D LS and indoor humidity: Press . JUMPER +VR LS 7. Wall mount cover. Squeeze top-bottom to open. FROM FAN SET CS • To change the temperature unit: Press °C / °F. POWER SUPP LY GND 8. Humidity index chart CS AB • To set the temperature / humidity offset in 9. Outdoor temperature reading is displayed AB ID2 GND MANUAL or AUTO mode: 10. Temperature / humidity setting is displayed C DIP ID1 Switch 1. Simultaneously press and when viewing the 11. Temperature / humidity offset is displayed NO SCR- 12500 AIR SCR+ PRESSURE R G V temperature or humidity reading. 12. Indoor temperature / humidity reading is displayed SWITCH 2. Use or to change the setting (-3 to 3). 13. / : Increase / decrease setting; enter humidity / temperature offset setting 3. Press and simultaneously or wait 5 seconds to confirm and move onto the next setting. BACK VIEW WIRING TO RS-20. ELITE ROOM STEAM HUMIDIFIE R

GO Lo or Hi will flash on the display when: TAM G MEASUREMENT LO HI TP o OUTDOOR TEMP. SENSOR FUSE TP Indoor temp. Below 0 C Above o o o (NOT USED IN MANUAL MODE ON (32 F) 37 C (99 F) GND o DR Outdoor temp. Below -40 C Above EV2 (-40oF) 50oC STEAM G o HUMIDIFIER EV1 (122 F) CONTROL EV3 Humidity Below 10% Above 90% MODULE G LS FACTORY +VR INSTALLED LS SET JUMPER CS GND CS PRECAUTIONS AB AB ID2 GND This product is engineered to give you years of DIP ID1 satisfactory service. Here are a few precautions: 1. Terminals for connection cables Switch SCR- Do not allow excess humidification. Excess SCR+ • TO MOUNT THE UNIT R G V humidity can cause condensation and enable mold and mildew growth. • Do not tamper with the unit’s internal components. WIRING TO DS-15, RS-15, CS-15, DS-35, The unit contains no user-serviceable parts. RS-35, CS-35 ELITE STEAM HUMIDIFIER • The contents of this manual may not be reproduced without the permission of the manufacturer. NOTE The technical specifications for this product and OUTDOOR TEMP. SENSOR N2 the contents of the user manual are subject to change (NOT USED IN MANUAL MODE) GND N1 without notice. AB AB SPECIFICATIONS GND IN TYPE DESCRIPTION NO C Dimensions 84 x 84 x 20 mm NC H x W x D (3.3 x 3.3 x 0.8 inches) C Weight 95.4 g (3.4 ounces) NO Temperature °C / °F unit GND 24V Temperature -0°C to 37°C NOTE MOUNT THE OUTDOOR SENSOR operating (32°F to 99°F) • To remove the humidistat from the base, squeeze range Mount the sensor outside the house: the louvered base at the top and bottom. Temperature 1°C (2 °F) • Do not mount on South side of the house or in • Before wall mounting, please remove the gasket. resolution Before return air duct mounting, please remove the direct sunlight. • Humidity range 10% to 90% breakout piece. • Place at least 4 feet away from any exhaust vent. If in air intake, place 1 foot or closer to outside wall. Humidity 1% TECHNICAL SUPPORT • • Place at least 6” higher than possible snow. resolution General Filters, Inc. Tel: 248-476-5100 • Do not route sensor wire near high voltage wires. Power 18-30 Volts, AC 43800 Grand River www.generalaire.com FORM NO 13144 REV A. Novi, MI 48375 USA