1rcu a 1on

NWHO Series Light, Medium & Heavy Weight Oil Applications Applicatious

• Flange Heater Design light and Medium Weight Oil (20 - 23 W/ ln2) Ideal for temperature maintenance and for • 2- 14" Carbon Steel Pipe Body, improving flow characteristics of oils. They 150 Lb Construction are also used to heat Heat Transfer Oils under proper conditions.

2 • 1-200 kW Heavy or Fu el Oil (5 -15 W/ln )-Heating heavy oils reduces the viscosity, thereby im­ • 120, 240 and 480V, 1 & 3 Phase proving flow and process efficiency. Preheating fue l oils provides better atomization at the • General Purpose, Moisture burners and allows the use of lower grade fuel Resistant Terminal, Moisture oils. ResistanVExplosion Proof Enclosure Features Terminal Enclosures-Standard stock heater • 0.475" Dia. Steel Sheath terminal enclosures are El General Purpose. 2 Elements (12 - 23 Wlln ) Moisture ResistanVExplosion Proof E2 and Moisture Resistant E4 Enclosures are available • With & Without Thermostat as assembly stock. • UL, CSA, ATEX and Other Third Elements- Sturdy 0.475' diameter steel Party Approval, Listing or sheath elements provide superior strength and Certification Available on Many rigidity. Chromalox elements utilize high quality Models resistance wire lor coil construction. The coil is surrounded with high purity magnesium Wiring- Wiring terminals are spaced to pro­ oxide which is compacted to a dense solid to vide proper arcing and creepage clearances. ensure high thermal conductivity and dielectric Termination insulators provide electrical isola­ strength. tion between the terminals and the grounded Flanges- Carbon Steel Flanges are standard metal sheath to enhance personnel safety and on 3' and larger light and heavy weight oil equipment service life. Heavy duty jumper circu lation heaters. Flange dimensions conform straps and other terminal parts assure tight to ANSI B16.5 standards. connections and an extra margin of current carrying capacity. Vessels- Chromalox vessels consist of a pipe body, nozzles and end cap. The pipe body Control s-All stock and assembly stock and nozzles are ASTM A53B carbon steel pipe. heaters come equipped with mechanical AR The end cap or disk is ASTM A516 Grade 70 thermostats. These thermostats are suitable carbon steel plate. Mounting lugs are welded for most applications. Explosion-resistant and to the pipe wall. The vessel is wrapped with liquid-tight thermostats are provided on E2 thermal insulation and covered with a painted and E4 units, respectively. sheet metal jacket. WARNING - Hazard of Fire. These de· Baffle Assemblies - Internal baffle assem­ vices functi on as temperature controls only. blies are provided lor Chromalox circulation Because they do not fail-safe, an approved heaters for use in heating highly viscous or temperature and/or pressure safety control heavy fuel oils. Baffles reduce the internal must be used for safe operation. Consult cross sectional area thereby increasing the Controls section of this catalog . velocity of the fluid in contact with the heating Control Panels- Integral or remote mounted element sheaths. Increasing the velocity of control panels with electronic controls and the fluid reduces the tendency of heavy oils to solid state (SCR) or contactor power con­ overheat and break down or carbonize. trollers can be provided using virtually any combination of control devices. Consult the Co ntrols section for details. C:hronnalox ® ------~'111'1' 1rcu a 1on

NWHO&NWHOB Light & Medium Weight Oil Applications (cont'd) Specijicatio11s and Orderiug Informatio1l Dimensio11s {Inches)

NWH0-06

2" Pipe lnlet - ~~- 7- 1 :-fz---,..~=',.--..:.:.:::.:.::::::::::::__J ~ 8-5/8 _,..

NWH0-18

(3) 1" Conduit Openings

2·1/2" Pipe ~ Outlet 2 Mig. lugs Ea. with three 3/4" A - 10x1-1/8" Deep Holes on 1·3/4" Centers

2·1/2" Pipe - Stock Status: S = stock NS = non-stock Inl et To Order-specify model, volts, phase, kW, PCN and quantity. Note - Refer to the Controls section for control panels.

NWH0-27

(3) 1" Conduit - Openings

3" Pipe Outlet ~- 2 Mtg. l ugs Ea . with three 3/4" A · 10x1-1 /8" Deep Holes on 1·3/4" Centers 3" Pipe Inlet

C:hronnalox ® ------~*111119' 1rcu a 1on

NWHOR & NWHORB Dimeusious (Jucbes) Medium, Heavy & N\'(/JiOR-03 Fuel Oil Applications

3 -14" ANSI Blind Flange Design 1" Pipe Oullet 2 Mtg. l ugs Ea . • 3- 14" Carbon Steel Pipe Body, with two 3/8' - ..... A 150 lb Construction 16x1-1/2" Deep \ Hol es on 1-1 /4" Centers • 3-120kW T I y • 240 and 480V, 1 & 3 Phase 1" Pipe Inlet-,. 3/4' NPT '---gr=::_ • General Purpose, Moisture Pipe Plug Resistant Terminal, Moisture Note -Add 2' to A dimension tor E2 Resistant/Explosion Proof enclosure. Enclosure Applicatious Vessel - Pipe body and nozzles are ASTM • 0.475" Dia. Steel Sheath low A53B carbon steel pipe. The end disk is ASTM Watt Density Elements (12 - 15 Medium and Heavy Weight Oil - Low watt A516 Grade 70 carbon steel plate. Provided 2 W/ln ) density reduces the risk of damaging highly with thermal insulation and painted sheet viscous fluids. Improve flow ability of fuel oils. metal jacket. With & Without Side Mounted AR Thermostat (60 - 250°F) Features Wiring- Convenient field wiring termin als are provided for easy installation. Terminal Enclosure- E1 General Purpose • Ul, CSA, ATEX and Other is standard. E2 Moistu re ResistanVExplosion Controls - Series 03 and 06 stock and as­ Third PartyApproval, listing or Proof or E4 Moisture Resistant Enclosures sembly stock heaters come eq uipped with side Certification Available available. mounted thermostat. Series 18, 27 and 45 are furnished without thermostat. Elements-0.475' diameter steel sheath elements. WARNING - Hazard of Fire. These devices function as temperature controls only. Be­ Flange - 3- 14' ANSI B-16.5 Blind flange cause they do not fail-safe, an approved tem­ with 1/2' thermowell for th ermostat bulb and a perature and/or pressure safety control must 1/8' NPT threaded opening fo r a th ermocouple be used for safe opera ti on. Consult Controls or RTD. section of this catalog.

Specifications aud Orderiug 11lformatio1l Dimensions (ln.) Ckt & WI. kW Volts Phase Mode l Stock PCN (lbs.) Series 03 - 3 inch 150 lb carbon steel vessel- 3 steel elements (15 W/ln2) with side mounted thermostat - 1" NPT pipe inlet and outlet 3 240 1- 1 32-15/16 22-1/2 16-1/2 NWHOR-03-003P-E1 NS 010760 70 3 240 1-3 32-15/16 22-1/2 16-1/2 NWHOR-03-003P-E1 NS 101995 70 3 480 1-1 32-15/16 22-1/2 16-1/2 NWHOR-03-003P-E1 NS 010815 70 3 480 1-3 32-15/16 22-1/2 16-1/2 NWHOR-03-003P-E1 NS 010840 70 4 240 1-1 42-15/16 32-1/2 26-1/2 NWHOR-03-004P-E1 NS 010874 80 4 240 1-3 42-15/16 32-1/2 26-1 /2 NWHOR-03-004P-E1 NS 010903 80 4 480 1-1 42-15116 32-1/2 26-1/2 NWHOR-03-004P-E1 NS 010938 80 4 480 1-3 42-15/16 32-1/2 26-1/2 NWHOR-03-004P-E1 NS 010962 80 6 240 1-1 55-7/16 45 39 NWHOR-03-006P-E1 NS 010997 94 6 240 1-3 55-7/16 45 39 NWHOR-03-006P-E1 NS 102234 94 6 480 1-1 55-7/16 45 39 NWHOR-03-006P-E1 NS 011041 94 6 480 1-3 55-7/16 45 39 NWHOR-03-006P-E1 s 102250 94 ,.. Stock Status: S = stock NS = non-stock To Order-Specify model, volts, phase, kW, PCN and quantity.

Chromalox®______irculation

Dimensio11s (lnc!Jes} NWHOR & NWHORB NWHOR-45 Heavy & Fuel Oil Applications (Baffled) Specificntious and Orderi11g biformntio1l A c Mtg.lug 8 Centers

(3) 1" Conduit Openings

2·1tz" Pipe Outlet 2 Mig. Lugs Ea . with three 3/4" A -10x1-1/8" Deep Holes on 1·3/4" Centers Stock Status: S =stock NS = non-stock 2·1tz" Pipe - To Order - Specify model, volts, phase, kW, PCN and quantity. Inlet Note - Refer to the Controls section for control panels.

NWHORB-27 Orderiug Model Medium , Heavy and Fuel Oil biformntimt NWHO Oil Circulation Heater (3) 1" Conduit _.-_--~ --,.--.,.. Openings R Low Watt Density Elements To Order - Complete the 8 Internal Baffles Model Number Code Number of Elements using the Matrix 03 Three 27 Twenty Seven provided. 06 Six 45 Forty Five A 18 Eighteen Code kW

003P 3 020P 20 060P 60 3" Pipe 004P 4 025P 25 070P 70 Inl et 006P 6 030P 30 090P 90 OOBP 8 035P 35 125P 125 010P 10 040P 40 150P 150 012P 12 045P 45 175P 175 NWHOR-AA 015P 15 050P 50 200P 200 018P 18 Faceot\,M Code Terminal Enclosure ··~ E1 General Purpose .... '···w ,,. E2 Moisture ResistanUExplosion Resistant E4 Moisture Resistant j=j: 4}7%~7-3/4 - • 18~~ Se~::::~ries 8-13/16 - • 27 Series NWHORB18 030P E1 Typical Model Number Chronnalox®------l'lfilf' Circulation

GCHI & GCHIB Dimensiom (Inches) Steam, Air & Gas GCHI-03 Applications to 750°F1 3(4" NPT Pipe Plug

• 3 -18" ANSI Blind Flange Design 2 Mig. Lu gs Ea. with two 3(8" • 16xH(2" • 3- 18" Carbon Steel Pipe Body, Oeep Holes 150 Lb Construction (750°F Max. on H f4" Vessel and 1600°F Max. Sheath Centers Temp.)! For Stainless Steel Thermostat Pipe Body Construction, Refer to GCHIS Series Circ ulation Heaters. 1" Conduit Opening

• 3- 350kW Applicatiom Vessel - Pipe body and nozzles are • 240 and 480V, 1 & 3 Phase ASTM A53B carbon steel pipe. The end disk Steam, Air and Gas - Higher kW ratings for is ASTM A516 Grade 70 carbon steel plate. • General Purpose, Moisture larger industrial and commercial gas heating Provided with thermal insulation and painted Resistant Terminal, Moisture applications. sheet metal jacket. ResistanVExplosion Proof Enclosure Features Baffl e Assembly-Internal baffle assemblies are provided on GCHIB-18 models. Baffles re­ • 0.475" Dia. I NCOLOY~ Sheath Terminal Enclosure- E1 General Purpose duce the internal cross sectional area thereby 2 is stan dard. E2 Moisture Resistan UExplosion Elements (15 - 23 Wnn ) increasing the velocity of the gas. Increas- Proof or E4 Moistu re Resistant available. ing th e gas velocity reduces the operating temperature of the elements and the shell of • 3 and 5" with Side Mounted Elements- 0.475' diameter INCO LOY~ the vessel. Thermostat (200 - 550°F), 8, 1 0, sheath elements. 14 and 16" without Thermostat Wiring- Convenient fi eld wiring terminals Flange - 3 -10 ' ANSI B-16.5 flange with are provided fo r easy installation. • CSA and Other Third Party 1/2' thermowell for thermostat bulb and a Approval, Listing or Certification 1/8' NPT threaded opening for a Controls- Series 03 and 06 stock and as­ Available thermocouple or RTD. sembly stock heaters come equipped with side mounted thermos tat. Series 18, 27, 45 and 108 are furnished without thermostat. Specifications and Orderiug Iufomzatiou Dimensions (ln.) Ckt & WI. kW Vo lts Phase Model Stock PCN (Lbs.) Series 03 - 3 inch, 150 lb carbon steel vessel - 31NCOLOY• elements' (23 W/ln2) with thermostat 3 240 1-1 32-15/16 22-1 /2 16-1/2 GCHI-03-003P-E1 NS 013240 62 3 240 1·3 32-15/16 22-1/2 16-1/2 GCHI-03-003P-E1 s 103915 62 3 480 1-1 32 -15/16 22-1/2 16-1/2 GCHI-03-003P-E1 NS 013258 62 3 480 1-3 32-15/ 16 22-1/2 16-1/2 GCHI-03-003P-E1 s 103958 62 4.5 240 1-1 42-15/16 32-1/2 26-112 GCHI-03-04P5-E1 NS 013266 72 4.5 240 1-3 42- 15/16 32-1/2 26-1/2 GCHI-03-04P5-E1 NS 104070 72 4.5 480 1-1 42-15/16 32-1/2 26-1/2 GCHI-03-04P5-E1 NS 013274 72 4. 5 480 1-3 42-15/16 32-1/2 26-1/2 GCHI-03-04P5-E1 s 104117 72 6 240 1-1 55-7/16 45 39 GCHI-03-006P-E1 NS 013282 94 6 240 1-3 55-7/16 45 39 GCHI-03-006P-E1 s 104230 94 6 480 1-1 55-7/16 45 39 GCHI-03-006P-E1 NS 013290 94 6 480 1-3 55-7/16 45 39 GCHI-03-006P-E1 s 104272 94 ,.. Stock Status: S = stock NS =n on-stock To Order-Specify model, volts, phase, kW, PCN and quantity.

1. Outlet gas temperature must be kept below both maximum sheath and vessel temperature or element and heater damage may occur. Contact your Local Chromalox Sales office for application assistance. Chronnalox ® ------l*~¥14'1 1rcu at1on

GCHI & GCHIB Steam, Air & Gas Applications to 750°F1 (cont'd.) Specifications and Orderiug Iufomllltio1l Dimeusiom (Incbes) GCHI-45, 72, 108

Stock Status: S = stock NS = non-stock To Order-Specify model, volts, phase, kW. PCN and quantity.

1. Recommended temperature limits for all GCH heaters with carbon steel vessels and INCOLOY• elements are 1600•F maximum for the sheath temperature and GCHI-M 7so•F maximum for the vessel temperature at 5 psi pressure maximum. Exceeding these recommendations will void the factory warranty. Outlet gas temperatures must be kept below both the maximum sheath and vessel temperature or element and vessel damage may occur. Contact your Local Chromalox Sales office for assistance Face of in determining the gas flow characteristics and proper heater selection. Heaters Mig. Lu gs supplied without controls. / Pipe Body

Other Note - Refer to the Controls section for control panels. "'

Ordering Model Steam, Air and Gas to 7so•p l11Jonnatio1z GCHI Gas Circulation Heater - INCOLOY3 Elements- Steel Vesse l B Internal Baffles To Order - Complete the Cod e Number of Elements Model Number 03 Three 45 Forty Five using the Matrix 06 Six 72 Seventy Two provided. 18 Eighteen 108 One Hundred Eight 27 Twen!X Seven Code kW 003P 3 040P 40 150P 150 04P5 4.5 050P 50 200P 200 006P 6 060P 60 225P 225 009P 9 070P 70 250P 250 012P 12 075P 75 300P 300 020P 20 080P 80 325P 325 025P 25 090P 90 350P 350 030P 30 125P 125 Code Terminal Enclosure E1 General Purpose E2 Moisture ResistanVExplosion Resistant E4 Moisture Resistant I GCHI 45 072P E1 Typical Model Number

Chromalox® Circulation

Dimensious (Inches) NWHIS NW'H/S-03 Pure Water & Mildly Corrosive Solution Applications Specificatious aud Orderi11g biformatiou

1" Pipe Oull e l~-

2 Mig. Lugs Ea. wilh lwo 318" - 1611 ·1/2" Deep Holes on 1-1/4" Cenlers

1" Pipe Inle i 3/4" NPT Pip e Pl ug NWHIS-06

NWHIS-18 Stock Status: S = stock NS = non-stock To Order-Specify model, volts, phase, kW, PCN and quantity. (3) 1" Conduil Op enings Note - Refer to the Controls section for control panels.

Ordering Model Pure Water and Mildly Corrosive Solution biformation NWH Water Ci rculation Heater IS INCOLOY~ Elements- Stainless Steel Vessel To Order­ Complete the Code Number of Elements Model Number 03 Three using t11e Matrix 06 Six provided. 8 Eighteen Code kW 006P 6 040P 40 150P 150 012P 12 050P 50 175P 175 018P 18 075P 75 200P 200 NWHIS-AA 024P 24 100P 100 030P 30 125P 125 Code Terminal Enclosure ,:, ;~::: , {?} "" .... E1 General Purpose E2 Moisture ResistanVExplosion Resistant E4 Moisture Resistant 3·3/8 • • 03 Series 4·17/32 • • 06 Series 7·3/4 • - • 18 Series 8·13/16 • - • 27 Series NWH 03 006P E1 Typical Model Number Chromalox 1rcu ation

GCHIS, GCHISB & GCHISR High Temperature Gas Applications to 1200°F1 Specijicatious and Ordering Infomzation Dhmmsions (Inches) GCHIS-03

2 Mtg. lugs Ea . wllh two 3/8" - 16x1-1,T Deep Holes on 1-1/4" Centers

2 Mtg. l ugs ~---i=- 2· Pipe Ea. with two Outlet 3/8"- 16x1-1/T Deep Holes on 1-114" Centers 8 A

1:---1--t-2" PIpe Inlet

GCHISB-18

Stock Status: S =stock NS =non-stock To Order-Specify model, volts, phase, kW, PCN and quantity. 2·1/T 1. Recommended temperature limits for all GCH heaters with stainless steel vessels and Pipe Outlet INCOLOY• elements are 16000 F maximum for the sheath temperature and 12000 F 2 Mig. lugs maximum for the vessel temperature at 5 psi maximum pressure. Exceeding these Ea. with three recommendations will void the factory warranty. Outlet gas temperatures must be kept 3/4" - 10x1-1/8" below both the maximum sheath and vessel temperatures or element and vessel Deep Holes damage may occur. Consult factory representative for assistance in determining the on 1-3/4" gas flow characteristics and proper heater selection. Centers 2-1/2" Pipe Inlet Other Note - Refer to the Controls section for control panels.

(3) 1" Conduit Openings

Chromalox®______Circulation

GCHCIS DimellSions (Iucbes) Small Capacity/Low Flow Gas Applications

• Cartridge Heater Design

• Stainless Steel Pipe Body 8

• 0.5-3 kW I 3(4. 14· { NPT Inlet I---. • 120 and 240V, Single Phase ...:!

INCOLOY8 Sheath Elements (37 W/ln2) ,

• General Purpose, Moisture Resistant Terminal, Moisture Heater with E2 Terminal Enclosure. ResistanVExplosion Proof Enclosure Specificatious aud Ordering bifomratiou • Internal Overtemperature Protection (type K T/C)

• Process Temperature Sensor in Outlet (type J T/C)

Applications

Gas - Designed to efficiently hea t gases, particularly allow-flow rates and relatively high To Order-Specify model, volts, phase, kW, PCN and quantity. temperatures. (Outlet temperatures to 600°F.) 1. Order Electronic Controls separately for remote mounting. Consult Controls section for details. Features 2. Special voltage and wattage ratings available. Contact your Local Chromalox Sales office. Terminal Enclosure- Avai lable with E1 General Purpose or E2 Moisture ResistanV Ordering Model Small Capacity/Low Flow Gas Explosion Proof. biformation GCH Gas Circulation Heater Cartridge Heater Element- INCOLOY3 Cartridge Element To Order­ c sheath and spiral woun d baffle fo r efficient heat IS INCO LOY®Sheath- Stainless Steel Vessel transfer. Complete the Model Number Code Number of Elements Vessel- Stainless Steel (304) construction of using the Matrix 01 One all wetted parts. provided. ------Code Watts------Thermal Insulation - High temperature pipe OP50 500 002P 2,000 insulation inside protective outer jacket. 001P 1,000 003P 3,000 Process Control -Accurate process control Code Terminal Enclosure using a Type J thermocouple located in the E1 General Purpose heater outlet. E2 Moisture ResistanVExplosion High Limit Sensor - Integral overtemperature Resistant protection using a Type K thermocouple located I inside the cartridge heating element sheath. GCHCIS 01 OP50 E1 Typical Model Number Installation - Compact rugged design permits easy installation.

C:hronnalox®______~,lfiEI' 1rcu a 1on

Circulation Heater Systems ASME & Custom Engineered Units Features Kilowatt Selections- Custom units can Mounting lugs or Mounting Saddles - Spe­ produce the required kilowatt ratings with ele­ cial mounting Jugs or mounting configurations are available. Mounting saddles are provided • ASME Certification to Section I, ment watt densities carefully selected for the specific media. with slotted mounting holes to allow for Ill, IV and VIII, Div. 1 PED expansion. • Custom Vessel Designs and Flanges, Fittings, Nozzles and Nozzle Orien­ Configurations Per Customer tation -Special nozzles, nozzl e flanges and Specifications nozzle orientation can be designed to meet virtually any customer requi rement. • Custom Designed Mechanical Distributed Wattage Elements- Help co ntroi -.;;J;a• and Solid State Controls and vessel wall temperatures on high temperature Control Panels gas circu lation heaters.

• Variety of Vessel Materials Control Panels -Integral or remote mounted Available Including Carbon Steel control panels with electronic controls and and 300 Series Stainless Steels solid state (SCR) or contactor power con- trollers can be provided using virtually any • Standard and Special Kilowatt combination of control devices. Consult the Co ntrols Section for details. Ratings Ordering Information-Selection and design • Standard and Special Voltages of a custom or ASME circulation heater system requires critical engineering judge­ • NEMA 1, 4, 7 & 12 Control Vessel Pressure-Temperature Ratings­ ment. Chromalox representatives can help you determine the correct specifications for your Panels and E1 , E2 and Non-ASME and ASME ratings to 2500 lbs and E4 Terminal Enclosures operating temperatures to 1500°F are avail­ application. To properly design your entire system you should clearly define the following: able. low temperature and cryogenic designs • Third Party Certifications and ratings are also available. The following forms PE306 or PE307 can be Available on Many Units used to help specify the correct circulation Se1·ies Momzted System heater system fo r your application. Voltage Ratings- Standard and special volt­ For further assistance in specifying and de­ Applications ages up to 600 volts. tailing your requirements, consult your local Chroma lox Sales office. Customer Specifi cations -Chromalox satis­ Electronic Controls and Control Panels­ fies many customer requirements using exist­ Electronic controls and panels for process and ing stock sub-components from our extensive overtemperature control are available mounted inventory. However, when an application calls on the units or as remote units. for a heater other than a catalog item, stock or assembled stock design, Chromalox has Process Thermocouples and Sensors ­ many special features and variations that can Thermocouples or RTD sensors can be be added to circulation heaters to meet special mounted in vessel nozzles. customer req uirements. Overheat Thermocouples on Sheath- Ther­ mocouples can be mounted on the element sheath(s) to sense sheath temperature and protect th e heater. High Temp erature Standoffs for Termi nal Enclosures-Terminal enclosures on high temperature heaters can be mounted with standoffs to reduce enclosure te mperatu res.

C:hronnalox®------~'lfE~II• 1rcu at1on

Circulation Heater Systems ASME & Custom Engineering Specifications (cant' d) Form PE307 Page 1 of 2 Customer Name: ------Reference: ------Date: - - - --

16.5 Orientation Number 18.1. 18.2 Mountin g Lug or Mounting Saddl e Orientation Number (1, 2, 3 or 4)

Or ie l ~ 1 A 10 8

Orlenlalion

9, 17 3, 4, 5

16.1, 16.2, 1 Flanged Nozzles 16.1. •n.,..-.-­ 16.4 Localion NPT No~zz~l es~- 16.4location

Note - Drawing is for Illustration Purposes Only. The flange size, number of heating elements, terminal enclosure configuration etc., will vary according to options selected.

Opemting Conditions 4. FLANGE AND VESSEL MATERIAL: 1. HEATED MEDIUM: 0 Carbon Steel o Carbon Steel-Galvanized 2. TEMPERATURE IN: OF TEMPERATURE OUT: OF o 304 Stain less Steel o Other (Specify) 3. FLOW RATE: SCFM or GPM or 5. FLANGE RATING: 0 Class 150 0 Class 300 0 Oth er (Specify) Lbs/Hr or 0 Other (Specify) 6. HEATING ELEMENT WATI DENSITY: 0 6.5 W/ln2 0 15 W/ln2 4. OPERATING PRESSURE: psig. 0 23W/In2 o 45 W/ln2 0 Other (Specifv! 5. DESIGN TEMPERATURE: °F Max. °F Min. 7. HEATING ELEMENT SHEATH MATERIAL: 6. DESIGN PRESSURE: psig. o Stee l o Copper 0 304 Stainless Steel 7. 0 Indoor o Outdoor o 31 6 Stainless Steel 0 INCO LOY~ 8. HAZARDOUS AREA ENVIRONMENT: o Other (Specify) Class Div. Group 8. TERMINAL SEALS: 0 Yes o No 9. AMBIENT TEMPERATURE: OF o Silicone Resin (450°F) 0 Silicone Fluid (500°F) Heater Specificatious (Check All Thnt Apply) 0 RTV (450°F) 0 Epoxy (250°F) 1. RATING: 0 Hermetic (Maximum 1000°F Sheath Temperature) Volts Phase Kilowatts o Oth er (Specify) 2. NUMBER OF ELECTRICAL CIRCUITS: o Standard 9. TERMINAL ENCLOSURE: 0 General Pu rpose o Ot her: No. of Circuits kW/Circuit 0 Moisture Resistant 0 Explosion Proof 3. NOMINAL FLANGE &VESSEL SIZE/NO. HEATING ELEMENTS: 10. TERMINAL ENCLOSURE STANDOFFS: o Yes o No 0 3'/3 0 6"/12 0 8'/18 0 4' 0 6' 0 Other (Specify) 0 10'/27 0 12'/36 0 14'/45 11. BODY FLANGE GASKET: 0 16'/72 0 18'/108 0 Other (Specify) o Standard 0 Spiral Wound 0 Other (Specify) Chronnalox®------l'lfiQII Circulation

Circulation Heater Systems Custom Engineering & Manufacturing

Chromalox has the engineering and manufac­ The heaters and control panel are rigidly A wide variety of solid state and electro-me­ turing capability to provide complete circula­ mounted on a sturdy metal frame . Control chanical controls can be found in the Controls tion heater systems for most process heating sensing devices are pre-wired to the heater. section of this catalog. applications. These systems are engineered The only installation required is to connect the for the specific requirements of kilowatts, flow piping system to the heater inlet and outlet These Control panels maintain process tem­ rate, fluid velocity, pressure, temperature and an d wire the power connection to the control peratures and can provide high limit control. On-off or proportioning type solid state con­ space limitations of each application. panel. trols complete with stepdown transformer, line Experienced ASME certified welders ensure Electrical enclosures are available for indoor, fusing , pilot lights, contactors or SCR's, and the structural integrity of large pressure vessel outdoor and hazardous areas. cooling fan as necessary are pre-wired and circulation heater. mounted in an enclosure. Outdoor hazardous Chromalox circulation heater systems can area enclosures are also available. If standard products and options do not fit include complete Control Panels, integrally your requirement, contact your local Chromal­ mounted or separate, to greatly reduce the ox Sales office for further technical assistance. time spent installing and starting up the appli­ cation. By pre-engineering systems with all the Custom engineered circulation heaters are skid correct components, including sophisticated mounted for easy installation, and supplied temperature and power controllers optimum with an integral control panel. performance is enhanced while guess work is minimized.

Chrornalox®------l'lfi2'1 ac age ystems

Packaged Systems Overview

Packaged , ------System 1 I Heat Transfer Systems Vaporizers Type I ~------===~~----~ • Heat Transfer Systems I Hot Oil Systems I I I Hot Water Systems • Large Tank Immersion Heaters L- - • Steam and Hot Water Steam Boilers I large Tank Heaters

Applicntious Increasing Operating Temperature Chromalox Packaged Systems are safe, versatile and easy to use heati ng systems for commercial and industrial applications. Applicatiou E11giueering Staudm·ds & Specials Pre-engineered and constructed with carefully matched components, the systems provide The Chromalox sales and service organization Chromalox has many standard and stock units easy installation and trouble-free operation in has the tech nical capabilities and equipment which will fit many of the more common heat­ the end user's application. to satisfy virtually any heating or heating and ing applications. However, Chromalox cuc•n•,-••-• Heat Transfer Systems- Ch romalox Pack­ cooling re quirement. To assist you in calc ulat­ ers are not limited to "Standards". Chromalox aged Heat Transfer Systems come complete ing requirements for the more common pro­ specializes in designing systems to match with integral controls and can be used to heat cess applications, we use three computerized specific process requirements and a special and pump hot or cold flu ids such as water, heat loss programs: system designed for your unique application. Some of the more common special require- water-glycol solutions and a wide variety of • Platen Mold and Die Heating Calculations heat transfer fluids including Oowtherm~ . ments include special ratings, sizes and con ­ Therminol~ and Syltherme 800. Optional cool­ • Jacketed Vessel Heating Calculations figurations such as a multiple zone systems ing modules are available. where each zo ne is an independent system of • Roll Heating Calculations. heating and cooling sections mounted on a Large Tank Heating System s- Chromalox common base. All work is performed in th e strictest con­ Packaged Large Tank Heating Systems are fidence. The Chromalox organization is the uniquely designed to heat large storage tanks Hundreds of other options are available most experienced and diversified manufactur­ located above or below ground and contain­ including solid state temperature controllers er in the electric heating business. Whatever ing highly viscous fluids or heat sensitive with proportional or relay output, solid state your heating requirements, you ca n depend materials. se quence rs, ti mers. alarms, solid state power on the technical know-how of your Chromalox controllers (SCR's), recorders, programmable Steam & Hot Water Boilers - Chromalox field representatives. Backed by highly skilled contro llers or recorders with digital comm uni­ Packaged Electric Steam and Hot Water engineers and modern manufacturing facili­ cations linked to your computer or distributed Boilers are safe and versatile heat sources ties, Chromalox field sales engineers can help process system (OPS). that produce low or high pressure steam determine your re quirements and provide you or hot water for commercial and industrial with high quality equipment, properly selected, processes and for comfort heating applica­ sized and applied. tions. Chromalox electric boilers can be used Note -The Chromalox sales organization anywhere steam is requ ired and electric power ca n provide its customers with heat loss is available. They are packaged units that oper­ calculations, design layouts and equipment ate from existing distribution voltages, making recomme ndations as a courtesy and on a no­ installati on simple. charge basis. Neither Chromalox or its factory representatives assume any liability for the final selection, suitability or performance of the heating equipment in the end application, except as defined in our published equipment warranty at the back of this catalog.

Chronnalox® ------~•11·111' Packaged Systems

Heat Transfer Systems Application Data Heat Tmmfer Systems- Reference Guideliues Heat Operating Operating Heat Transfer Systems can be categorized Transfer Pressure Tern . Maximum (grouped) by the type of flu id used in transfer­ Fluid ( si I (oF kW' Model Page ring the heat to the process. Water and Water/ Water Atmospheric 300 600 CMX 0-5 Glycol systems can be used for temperatures Atmospheric 250 24 MWS D-6 up to 300°F. Special heat transfer fluids and Atmospheric 250 600 CWG 0-9 oils can operate up to 750°F and the fluid Oil Atmospheric 550 24 CMXO 0 -11 Atmospheric 650 500 MOS D-12 vaporizer systems utilize vapor phase heat en­ Atmospheric 650 400 COS-8 0-15 ergy to give a higher heat of 750°F with lower Atmospheric 600 600 PFC D-17 operating pressures (150 psig). OiVPressurized 200 750 600 CLS-A 0-19 The Reference Guidelines and General Vapor 50 750 300 CHlV D-25 Specifications give more information to help System Options 0-22 your selection. Detailed product information II"' 1. Higher kW ratings available. Contact your Local Chromalox Sales office. appears in the following pages. Be11ejits & Advautages Heater Burnout Protection-Every heating Optional Controls- All Chromalox heat Reliable and Proven Designs - Backed by chamber has an overtemperature cutout which transfer systems are available with the latest almost1 00 years of engineering and manufac­ will de-energize the heater in case of an over­ state-of-the-art solid state controls. These turing of electric heating equipment, Chro­ temperature condition. include microprocessor-based, recording and malox electric fluid heat transfer systems are SCR power controllers that can control fluid safe, versatile and easy to use, pre-engineered Matched Components - All Chromalox stan­ temperatures to ± 1° F. For a complete selec­ heating or heating and cooling systems which dard and special systems are pre-engineered tion of optional controls refer to the Controls operate at existing distribution voltages (208 with correctly sized and matched components section. - 600 Volts). such as pumping rate versus pipe line size, amperage draw versus electrical Safe and Reliable Electrical Wiring- All wir­ parts to ensure total system performance. ing complies with the National Electrical Code. Heat Trmzsfer Systems- General Specijicatio11s

Operating Max. Pressure Temp . Operating I Rating & IConnection Model I System Type I Application I (oF) I kW1 I Mbh ~ I Pressure I ASME Construction Type Mold Temperature CMX 125 Lb. Controller Water/Glycol 50- 250' 4.5-24 15.3-81.8 Atmospheric N/A3 Threaded NPT Heat Transfer MWS 150 Lb. Non-Pressurized Water/Glycol 50 -300 50-600 307-2,047 Atmospheric Optional Welded Flanged Heat Transfer CWG 1 150 Lb. Non-Pressurized Water/Glycol 50-250 6 - 600 20.5-2,047 Atmospheric Optional Welded Flanged Heat Transfer WMHTS' Water/Glycol 50-2501 6- 1,200 20.5-4,094 150 Lb. NPTor Multiple Zone 125 psig Optional Welded Flanqed Heat Transfer Heat Transfer CMXO 50-550 6 - 24 3 125 Lb. Non-Pressurized Fluid/Oil 20.4- 81.9 Atmospheric N/A Welded NPT Heat Transfer MOS Heat Transfer 50-650 50-500 171-512 Atmospheric Optional 150 Lb. 150 Lb. Non-Pressurized Fluid/Oi Welded Flanged Heat Transfer Heat Transfer 50-650 9-400 30.7- 1,365 Atmospheric Optional 150 Lb. 150 Lb. cos Non-Pressurized Fluid/Oil Welded Flanqed Heat Transfer Heat Transfer PFC 50-600 9-600 30.7-2,047 150 Lb. 150 Lb. Non-Pressurized Fluid/Oil Atmospheric Optional Welded Flanqed Heat Transfer CLD Heat Transfer 50-750 9-600 30.7-2,047 150 psig 300 Lb. 300 Lb Pressurized Fluid/Oil Standard Welded Flanqed Heat Transfer CLS Syltherm• 800 100-750 9-600 30.7-2,047 300 Lb. 300 Lb. Pressurized 200 psig Standard Welded Flanqed Heat Transfer OMHTS4 Heat Transfer 50-750 9-1,200 30.7 - 4,094 300 Lb. 300 Lb. Multiple Zone Fluid/Oil 200 psig Optional Welded Flanqed Heat Transfer Dowtherm• CHlV -20 - 750 15-300 51.2-1,024 150 psig 300 Lb. 300 Lb. Vaporizer Therminol8 Standard Welded Flanqed ,. 1. Indicates standard models. Models available in other configurations. 2. Indicates standard design kW. Higher kW ratings available. 3. N/A indicates not available or not applicable. 4. Contact your Local Chromalox Sales office. 5. Mbh is the ASME & ANSI standard for one thousand British Thermal Units per hour. Other Notes - Use these selection guidelines as a reference to the availability of Chromalox Packaged Heat Transfer and Large Tank Heater Systems. If ~ou cannot find a system with all of the features required for your application, contact your Local Chromalox Sales o 1ce. Chromalox®______ac age ystems tnl croTHEI\M' CMX Water Circulating Applications Chromalox microTHERMTM CMX Series Temperature Controller Circulating Water Temperatu re Controllers are compact, versatile and completely self­ • Water and Water/Glycol contained water heating and cooling systems. Solutions to 250°F The CMX series products can be used in any .. application where precision temperature con­ trol of a heating and cooling water circulation • 4.5- 24 kW (15- 82 Mbh) system is needed. They are particularly useful in the plasti cs industry as mold temperature 240 and 480V, 3 Phase, 60 Hz controllers. • 125 Lb Carbon Steel • Injec tion Molding Machines- Options Construction Thermoplastics and Thermosets • Alternate Voltages available for 208 and • Platens and Dies • Heavy Duty 0.430" Dia. 575V, 3 Phase, 60 Hz, and 240, 380 and INCOLOV® Sheath Elements • Rolls, Laminating and Calendering 415V, 3 Phase, 50 Hz distribution systems • Alternate Pumps rated 1.5, 3, 5 or 7.5 hp • 3/4 HP Cast Iron Bronze Fitted • Pipeline Heating and Tracing with pumping capac ities to 80 gpm Centrifugal Pump (30 gpm • Jacketed Vessels and Ta nks @ 70 psi TDH @ 20 psi TDH) The built-in electronic temperature and • Power Controllers- Electronic Solid State • Electronic PID Temperature and process controller features separate PID algo­ (SCR) Process Control (Dual Display) rithms for heat and cool control modes, dual display of setpoint and process temperatures • Surge Reduction Valve and simple configuration parameters with • Built-in Diagnostics with • Digital Communication Interface alphanumeric cues. Even though micro­ Indicators for Pump Overload, TH ERMTMsys tem s are sophisticated and state • Expanded Open or Closed-loop Cooling Low Water Pressure and of the art, they are easy to use and require Overtemperature ve ry little training to program and operate. • High Temperature Operation to 275°F Standard NPT threaded piping co nnections • Electrical Enclosure Door Interlock • Compact, Portable Cabinet with provide for convenient hook up to external Casters piping. • IEC Style "dry contact" Power Contactor. • Features Easy Access Service Specifications and Ordering bifonnatiou • NEMA 1 Electrical Enclosure with 120V Control Transformer and Mercury Contactors for Quiet Operation and Long Life

• Dual Pressure Gauges Monitor Pressure To and From Process

• Open or Closed-Loop Cooling (3.8 Ft2 Heat Exchanger)

• Automatic Air Purge Valve

• Large Diameter (1-1/4" NPT) Process Piping Connections

• ASME 125 psig Relief Valve

Chromalox®______ac age ys ems

MWS Water and Water/Glycol System (cont'd) Sta11dard Features Benefits Electronic Process Control ...... Precise process control Element Overtemperature Protection ...... Protect elements and flu id from ove rh eating Air-Cooled Mechanical Seal...... No external cooling needed Insulated Heating Chamber ...... Maximize efficiency by minimizing heat loss Discharge Pressure Gauge ...... Confirm pump operating performance Compact Footprint ...... Space saving design Fully Pre-wired & Tested ...... Ready to operate on site Centrifugal Pump ...... Minimize piping configuration Temperature rating to 3oo·F (150.C) ...... Covers most applications 150# ANSI Flange Conn ection ...... Easy fit up to in sta lled piping Start I Stop buttons with Motor Starter ...... Complete operating system Pilot Lights for Power, Heater, & Pump ...... Visual indication of system operation

Optious

• Electronic Solid State (SCR) Trim Power Control (standard on 300-600 kW units) • Strainer • Powder Coated or Stainless Ste el Side Coverings I Support • Dedicated Fill Connections • NEMA 4 or 4X (Stainless) Construction • Class 1, Div 2 Hazardous Area Rating (with purge) • Panel Disconnect Switch • Heater On/Off Switch • Suction Pressure Guage • Inlet I Outlet 150# Gate Valves • Drain I Bleed Values • Digital Overtemperature Controller • Relief Valve • AS ME Design & Certified, Section VIII, for 1o o psi at 3oo·F (1 50.C) • Heat Exchanger (shipped loose for customer installation) • Expansion Tank (shipped loose for customer installation) • Liquid Level Switch for expan sion Tank

Chromalox®______ac age ystems

CWG Hot Water Heat Transfer System

• Water and Water/Glycol Applicntiom Solutions to 250oF Chro malox CWG Series Hot Water Heat Trans­ 6-400 kW (15 -1,365 Mbh) fe r System s can be used in closed-loops with water or water-glycol mixtures to a maximum operating temperature of 250°F. Applications • 240, 480 and 550V, include heating only or heating and cooling 3 Phase, 60 Hz of jacketed vessels, rolls, heat exchangers, platens, dies an d molds requiring high and • 150 Lb Welded Steel uniform temperature throughout the process. Construction Fenhtres • Heavy Duty 0.475 " Dia. Copper Sheath Elements All exposed sides have heavy 16 gauge sheet metal panels for ope rator protection. Optiom • Cast Iron Bronze Fitted Special two-part epoxy paint, chemica lly • Expansion Tank (recommended) Centrifugal Pump with Cast resistant to heat transfer fl uids, assures good Steel Strainer (Capacities to looks and ease of cleaning fo r years. • Float and Level Switches 200 gpm @ 100 psi TDH) Standard NPT threaded piping connections • Open and Closed-loop Cooling Modules • Electronic Digital Temperature provide convenient hook up to ex1ernal piping. • Alternate Pumps and Pump Manufacturers and Process Control All electrical construction conforms to NEG standards with fusing on all internal circuits. • Electronic Process Controls • NEMA 1 Electrical Enclosure with Circuit Breaker, On-Off WARNING - In hazardous areas, pipe sur­ • Solid State Power Controllers Switches, Pilot Lights and 120V faces co uld achieve temperatu res high enough to cause auto-ignition of the hazardous • Electronic Sequencers, Recorders, Monitors Control Transformer (Standard) materials present. Consult Article 500 of the and Time Clocks National Electrical Code for further information • Other Voltages and Ratings to 1, 200 kW • NEMA 4, 12 and Explosion on the maximum allowable temperatures for a Available Resistant (Class I, Group D, specific application. Div. I see Note 1) Electrical Enclosures Available Specifictltio11S 1111d Orderiug Iuformfltiou • Dual Pressure Gauge Monitors Pump Inlet and Discharge Pressure

Bypass Safety Relief Line Protects Pump (Blocked Flow)

Manual Inlet and Outlet Valves for Isolation of Process

Manual Air Bleed Drain Valves

• ASME 125 psig Relief Valve

• Optional ASME Certification to Section IV or VIII for 125 psig @ 250°F

C:hronnalox ®------~·~··1•1 ac age ystems

nli croi'HEI\M" - CMXO Applicatious Chromal ox Compact Oil Temperature Co ntrol· Circulating Oil lers are enginee red to operate up to 550°F at atmospheric pressure (non-pressurized). Th ey Temperature Control are particularly useful in the plastics industry for use with plastic materials that require System higher temperatures than can be achieved by hot water systems. • Heat Transfer Fluids to 550°F • Injection Molding Machines- Thermos- ... plastics and Thermosets • 6-24 kW (15- 81Mbh) • Platens and Dies • 240 and 480V, 3 Phase, 60 Hz • Rolls, Laminating and Calendering • • Non-Pressurized (Atmospheric) • Pi peline Heating and Tracing Operation • Jacketed Vessels and Tanks

• 0.430" Dia. Steel Features (Jon not in

Chromalox®______Packaged Systems

Sttmdm·d Features Beuefits

MOS Electronic Process Control ...... Precise process co ntrol Hot Oil System Element Overtemperature Protection ...... Protect elements and fluid from overheating (cont'd.) Air-Cooled Mechanical Seal...... No external cooling needed Insulated Heating Chamber ...... Maximize eff iciency by minimizing heat loss Discharge Pressure Gauge ...... Confirm pump operating performance Compact Footprint ...... Space saving design Fully Pre-wired & Tested ...... Ready to operate on site Centrifugal Pump ...... Minimize piping configuration Temperature rating to 6oo·F...... Covers most applications 150# ANSI Flange Connections ...... Easy fit up to installed piping Start I Stop buttons with Motor Starter ...... Complete operating system Pilot Lights for Power, Heater, Pump ...... Visual indication of system operation

Optiom

• 65o·F Operation • Electronic Solid Slate (SCR) Power Control • Strainer • Powder Coated or Stainless Steel Side Coverings • Dedicated Fill Connection • NEMA 4 or 4X (Stainless) Construction • Class 1, Div 2 Hazardous Area Rating (with purge) • Panel Disconnect • Heater On/Off Switch • Suction Pressure Guage • Inlet I Outlet #150 ANSI Gate Valves • Drain I Bleed Valves • Digital Overtemperature Controller • ASME Designed and Certified, Section VIII, tor 100 psi at600/650.F • Higher Flow Pump (350-500 kW units only) • Heat Exchanger (shipped loose tor installation) • Expansion Tank (shipped loose tor installation) • Liquid Level Switch tor Expansion Tank

C:hronnalox ® ------~•E·•mfl' ac age ystems

COS-B Hot Oil System •

• Heat Transfer Fluids' to 650°F

• 9 - 400 kW (31 - 1,365 Mbh)

• 240 and 480V, 3 Phase, 60 Hz2

• Non-Pressurized (Atmospheric) Operation

• 150 Lb Carbon Steel Construction

• Long Life 0.475" Dia. Steel Applicatiom Comtntctiou Sheath Elements Chromalox COS Hot Oil Heat Transfer Systems Chromalox COS systems are ruggedly con­ are engineered to operate up to 650°F at structed and completely self contained (except • Positive Displacement, High­ atmospheric pressure (non-pressurized). They for the optional external expansion tank). All Temperature Pump with lnline are used with Mobiltherm~, Ucone, Calo ri a® Chromalox hot oil heat transfer systems have Strainer and other medium temperature heat transfer similar components and construction features. fluids' which do not require pressurization to All systems come complete with heaters, • Bypass Relief Valve Protects operate at temperature. controls, pumps, valves, safety devices and System (Factory Set 45 psi) necessary plumbing. Systems are factory COS heat transfer systems use a cold tested and ready to operate. • Electronic Digital Temperature expansion tank (optional) that is open to the and Process Control atmosphere. A cold expansion tank eliminates the need for nitrogen (N2) purging and reduces • Suction and Discharge Pressure the tendency of heat transfer flu ids to oxidize and deteriorate. Gauges Monitor Pump Performance 1jpical Piping Sc!Jematic Jot· No11-Presmrized (Atmosp!Jeric) COS Systems

• NEMA 1 Electrical Enclosure Eleclronlc Optional Low Complete with Circuit Breaker, Temperalure Heat Exchanger Fluid Level ~ [" Conlrol (Optional) Control f ~ Contactors, Fusing, Switches, I I I Transformers and Pilot Lights r-~- Air Bleed L r' '-Sight Glass I lr I 1 r'{, ~ L- L I 1 =)'] L--..._---,-,---' • External Cold Expansion Tank : fl ~ I I ' (Optional) with Atmospheric 1 1 '\.. Expansion Tank 1===~~ - _J Vent l .., ,-..,,.J: Air Bleed } I I ~ : ;-,. To Process Water Out '-150 Lb Flange Water In 150 Lb Flange Chromatox -...... _ Heater t Pressure >;:::::=::t;'"-;n::::;-;:=i....:t::~==l From Process Gauge (D IS\ ::=-c charge) '4 ?- Gate Valves -c- Fill Line Strainer """'- Flexible Pipe Pressure Gauge (Suction) "--Posillve Displacement Pump

Notes - 1. For a complete list of compatible heat transfer fluids, contact your Local Chromalox Sales office. 2. Other voltages available, contact your Local Chromalox Sales office. Chromalox®______Packaged Systems

PFC-B

Hot Oil System Ill Ill 0 0 0 •• ~ • Heat Transfer Fluids1 to 600°F i•;••• o.• •• - • 9- 600 kW (31 - 2,047 Mbh)2

240 and 480V, 3 Phase, 60 Hz3

• Non-Pressurized (Atmospheric) Operation

• 150 Lb Carbon Steel Construction

• Long Life 0.475" Dia. Steel Sheath Elements

• High Temperature Centrifugal Pump with Labyrinth Seal Ring Applications Coustntction - Requires No External Cooling up to 600°F Chromalox PFC Hot Oil Heat Transfer Systems PFC systems are ruggedly constructed and are engineered to operate up to 600°F at completely self contained (except for the • Bypass Relief Line Protects atmospheric pressure (non-pressurized). They optional external expansion tank). They are System in Case of Blocked Flow are used with Mobiltherm®, Uco n~. Ca l or i a~ similar to the COS system except they use a and other medium temperature heat transfe r high temperature centrifugal pump instead of Electronic Digital Temperature fluids• which do not require pressurization to a positive displacement pump. The centrifugal operate at temperature. pump has a labyrinth seal ring which does not and Process Control require cooling up to its maximum operating PFC systems use a cold expansion tank temperature of 600°F. PFC systems come • Suction and Discharge Pressure (optional) that is open to the atmosphere. complete with heaters. controls, pumps, Gauges Monitor Pump A cold expansion tank eliminates the need valves, safety devices and necessary plumb­ for nitrogen (N ) purging and reduces the Performance 2 ing. Systems are factory tested and ready to tendency of the heat transfer fluid to oxidize operate. • NEMA 1 Electrical Enclosure and deteriorate. Complete with Circuit Breaker, Contactors, Fusing, Switches, Transformers and Pilot Lights

• External Cold Expansion Tank (Optional) with Atmospheric Vent

WARNING -In hazardous areas, pipe sur­ faces could achieve temperatures high enough to cause auto-ignition of the hazardous materials present. Consult Article 500 of the National Electrical Code for fu rther information on the maximum allowable temperatures for a specific application. A. PumpinQ rate based on 100 ft. total discharge head (TDH) using heat transfer fluid with a viscos•ty of approximately 100 SSU @ ?O•F.

Other Notes - 1. For a list of compatible heat transfer fluids, contact your Local Chromalox Sales office. 2. kW ratings above 600 (to 1,200 kW) available. 3. Other voltages to 575V available.

C:hronnalox®------~•1·1111'' ac age ystems

CLS-A Hot Oil System liJlll • Heat Transfer Fluids' to 750°F 0 0 ... ~ • 9 - 400 kW (31 - 1,365 Mbh) •• ~.i.i (Up to 1, 200 kW Optional) •••• - • 240 and 480V, 3 Phase, 60 Hz

• Pressurized Operation - ASME Certified to 200 psig @ 750°F

• 300 Lb Carbon Steel Construction

• Long Life 0.475" Dia. Steel Sheath Elements

• High Temperature Centrifugal Applicatiom Coustntctiotl Pump with Water-Cooled Chromalox CLS Hot Oil Heat Transfer Systems Chromalox CLS Hot Oil Heat Transfer Systems Mechanical Seal are engineered to operate up to 750°F at a are ruggedly constructed and completely self pressure of 200 psig. They are used with contained (except for the optional external • Bypass Relief Line Protects Syltherm~ 800 and other high temperature expansion tank). All CLS systems come System in Case of Blocked Flow heat transfer fluids' which require heated lines complete with heaters, controls, pump valves, to prevent crystallization of the media and safety devices and necessary plumbing. The • Electronic Digital Temperature pressurization to operate at temperature. high temperature cast steel centrifugal pump and Process Control is provided with a water cooled mechanical CLS systems use a pressurized hot expan­ seal designed for continuous operation at a sion tank (optional) that is heated by hot heat maximum temperature of 750°F. CLS systems • Suction and Discharge Pressure transfer fluid flowing through it. The expan­ are factory tested and ready to operate. Gauges Monitor Pump sion tank is ASME coded for 650°F @ 200 psig with an ASME safety relief valve. Nitrogen (N ) Performance 2 purging is required. • NEMA 1 Electrical Enclosure Complete with Circuit Breaker, TYpical Pipiug Schematic for Pressurized CLS Systems Contactors, Fusing, Switches, Heat Transformers and Pilot Lights Electronic Temperature Control Exchanger Low Level Fluid \ r- (Optional) Control (Optional) "~,t, If'. • . : : / ASME Sight Glass • ASME Safety Relief Valve (Set @ tlr""l~ - AtrBieed ';J \ 200 psig)

WARNING -In hazardous areas, pipe sur­ faces could achieve temperatures high enough to cause auto-ignition of the hazardous materials present. Consult Article 500 of the National Electrical Code for further information on the maximum allowable temperatures for a specific application. Note 1 - For a complete list of compatible heat transfer fluids, Chromalox®______contact your Local Chromalox Sales office. _ ac aged ystems

System Options Applicatious Siz ing An expansion tank is an essential component Expansion tanks should be sized based on Expansion Tanks to all heat transfer systems. Heat transfer the amount of thermal expansion of the heat fluids expand with an increase in temperature. transfer fluid in the system. The actual size of Dimensions (Inches) Expansion tanks allow for and contain the the tank should be at least double the antici­ increase in volume due to temperature. In pated increase in fluid volume. Tank capacity CWG addition, cold expansion tan ks provide a "seal" should be increased if the process piping is on the system reducing oxidation of the fluid. extensive and contains a significant volume of They also add to the net positive suction head fluid. The following tables indicate the typical

AI (NPSH) on the inlet to the pump. tank sizes for most systems. -... I I Steel Tmzks Non-ASME mted 75 psigfo,· MWS, CWG, MOS, COS and PFC C B Heat Transfer Systems - includes sight glass, 1 11 NPT vent and 314 11 NPT or I I 150 Lb. •fomged system comzection. ! I

COS/PFC

_I Stock Status: S =stock NS =non-stock AB To Order-Specify tank capacity, system type, kW, PCN and quantity. I c I Steel Tanks ASME rated 200 psig @ 650°F for CLS He11t Transfer Systems ­ y includes ASME reliefvalve, reflex type sight glass and two I 11 300 Lb. flanged 0• 11 ) y y system connectio11S. Two I/4 NPTfittiugs are providedfor nin·ogen (N1 I _...1-- 3/4"150 lb. Fig. p urge comzections. I ~ - A- .-1

CLS

Stock Status: S =s tock NS =non-stock To Order-Specify tank capacity, system type, kW, PCN and quantity.

C:hronnalox ® ------~•11·111'1 ac age ystems

Impedance Heating System

• Uniform, Indirect Heating

• Distances of up to Several Miles in Length

• 1kW to Several MW of Power

• Low Voltage Operation in the Shown Above: Impedance Heating Skid System Process (less than SOV) Fluid ?";r Outlet • Temperatures to 1aoo·F

• Watt Densities up to 190 W/in2

• Hazardous Area Certifications Available u

Shown Above: Heat Transfer and Process liquifications

Desct-iptiou • Uniform Healing • rather than having Impedance style heating, through the Joule localized 'hot spots' for transfering energy, effect, uses the pipe itself as the heating Impedance heating allows for even, smooth source. This allows uniform heating around heating along the entire circumference and the process with miminal impact on the instal­ length. lation site. • Simple Installation ·As compared to Applicatiou - Heat Tmusfer & electric heating elements, additional piping, valves, wiring, etc are not needed to ac· Process LiquificatiollS commodate Impedance heating. Impedance Impedance is a unique solution for raising the utilizes the pipe itself and minimizes the temperature of a process stream. Impedance amount of eqipment needed. uses the pipe itself to transfer heat, so no piping modifications are requ ired. Common • Efficient, Compact area for heat transfer­ applications include fluids that are th ermally Impedance heating allows higher watt densi· sensitive and/or highly viscous. An impedance ties to be used due to increased velocities system is also ideally suited for fluids that and lower pressure drops. may solidify in the piping and need liquefied • Indirect Heating Contact ·There are no prior to pumping. Impedance can gradually concerns of corrosion on a heater sheath as and evenly warm a process, such as paraffin, the process is only heated by the pipe. from a coagulated state to a fully liquid state for pumping. • Can handle warm up or temperature main· tenance conditions • Impedance heating can Applicatiou -Heat Tmciug and be use for simply maintaining pipe tempera· Freeze Protectiou lures or adding additional power to heat-up Impedance heating is perfectly suited for pipe liquid flow. Impedance can also be used to maintenance temperatures. Applications liquify coag ulated fluids when re-starting a include processes that require continuous, system. steady heat input or freeze protection for a fire • No routine maintainence needed - Imped­ water pumping system. Another common ap­ ance has no moving parts that require ser­ plication is for corrosive environments where vicing or that can cause costly shutdowns direct immersion heating is not desired. on operations. Advautages • No double jacketing • Steam or oil traced • Accurate temperature control to +-1 ·F - lines have additional hazards of frozen lines, Available SCR power control can accurately or leaky connections. Impedance totally monitor and control desired temperature eliminates these concerns. C:hronnalox ® ------~•l· lfill' Packaged Systems

CHTV Heat Transfer Fluid Vaporizer

• Heat Transfer Fluids (Vapor Phase) to 750°F

• 15-300 kW (51 -1,024 Mbh)

• 240 and 480V, 3 Phase, 60 Hz Applicntious Features

• Pressurized Operation - ASME Chromalox CHTV Heat Transfer Fluid Vapor­ No pumps are needed for gravity retu rn sys­ Certified to Section VIII, Div. 1 ize rs are designed for use in textile, chemica l, tems. Low operating pressures. Hartford loop 150 psig @ 750°F petrochemica l and other industries requir­ piping for gravity return systems. Wirin g and ing high temp eratures and low operating fusing conform to NEG requirements. pressures in their manufacturing processes. • 300 Lb Carbon Steel Optiom Construction They operate to 750°F using Dowtherm~ A or J, Therminol~ VP-1 and other organic vapor phase heat transfer fluids. • Alternate Voltage and kW Ratings • OCE Open Coil Elements Removable w/o Draining Tank • Electronic Solid State (SCR) Power Advn1ltnges Co ntrollers. Digital Communication lnte available • Hartford Loop Piping Prevents Vapor system s transfer more heat energy per Siphoning of Fluid in Gravity pound of heat transfer medium than compa­ • Cond ensate Return Pumps Return Systems rable liquid phase systems. As the fluid vapor condenses to a liquid in the process piping, it • NEMA 4 (CHTVW) or Class I, Group D. Div. 1 • Pressure Control and Sequencer releases the latent heat of vaporization. Unlike El ectrical Enclosures (CHTVX) available steam, heat transfer fl uids operate at relatively for Process Control • Available wi thout Control Panel or without low pressures at elevated temperatures. Hartford Loop Piping • Operating Pressure Gauge Dowtherm®A only has a pressure of 102 psia @ 695°F. • Other Applications for Fluid Vaporization in­ • Over-Pressure Cutout Switch cluding Kerosene, Propane or Gasoline and Cryogenic Applications for Liquified Natural • Fluid Level Switch Locks Out Gas and Nitrogen Heating Elements if Low-Fluid Level Occurs Specificatious nud Orderi1lg bifomlfltiou IOperating Dimensions (ln.) I • Reflex Type High Pressure Vol. Tank No. WI. Liquid Level Sight Glass kW Btuh (Gal.) H W 0 Dia. Circ. Model Stock PCN (lbs. 15 51 ,180 15.7 50 36 80 16 1 CHTV-316-15 NS - 750 20 68,240 19.4 50 36 94 16 1 CHTV-316-20 NS - 850 • 5" Dia. Dial Type Thermometer 25 78,500 23.6 50 36 11 0 16 1 CHTV-316-25 NS - 975 with Thermowell 30 102,360 27.2 50 36 124 16 1 CHTV-316-30 NS - 1,075 40 136,480 35.6 50 36 156 16 2 CHTV-316-40 NS - 1,375 • ASME Relief Valve 50 157 000 43.5 50 36 186 16 2 CHTV-316-50 NS 1 600 40 136.480 75 60 48 95 24 2 CHTV-624-40 NS - 1,400 50 157,000 106 60 48 111 24 2 CHTV-624-50 NS - 1.650 NEMA 1 Electrical Enclosure 60 204,720 137 60 48 125 24 2 CHTV-624-60 NS - 1,800 Complete with Circuit Breaker, 75 235,500 168 60 48 149 24 3 CHTV-624-75 NS - 2,150 Contactors, Fusing, Switches, 100 341 200 218 60 48 187 24 3 CHTV-624-100 NS 2 600 100 341,200 218 66 54 111 30 3 CHTV- 1230-1 00 NS - 2,650 Transformers and Pilot Lights 125 392,500 222 66 54 129 30 4 CHTV-1230-125 NS - 3,000 150 511 ,800 263 66 54 149 30 4 CHTV-1230-150 NS - 3,400 175 549,500 300 66 54 167 30 6 CHTV-1230-175 NS - 3,850 WARNING - In hazardous areas, pipe sur­ 200 682 400 340 66 54 187 30 6 CHTV-1230-200 NS 4 300 faces cou ld achieve temperatures high enough 225 767,700 379 72 60 149 36 6 CHTV-1836-225 NS - 5,000 to cause auto-ignition of the hazardous 250 853,000 417 72 60 162 36 6 CHTV-1836-250 NS - 5,600 materials present. Consult Article 500 of the 275 938,300 455 72 60 175 36 6 CHTV-1836-275 NS - 6,000 National Electrical Code for further information 300 1.023 600 490 72 60 187 36 6 CHTV- 1836-300 NS 6,400 on the maximum allowable temperatures for a Stock Status: S = stock NS = non-stock Ill" To Order-Specify model, volts, phase, kW, options and quantity. spec ific application. Chromalox®______Packaged Systems

RSTO - Uuitary lmmersiou Heate1·s SHO Suction Heaters Large Tank Metal sheath or open coil elements are Heating of viscous materials, in large storage inserted into an assembly of 3' Schedule 40 tanks, to pumping temperatures. Maintaining NPS steel pipes. The pipes are welded into an an entire tank of viscous fluids such as fuel Heaters adapter box for convenient field welding of th e oil or asphalt at pumping temperatures is very entire assembly to the header of a steel tank. costly. In many applications it is not practical Application & The heaters are self co ntained with built-in or economical because the tanks are located controls mounted in a weather proof electrical underground or are not insulated. Equipment Selection enclosure. (cont'd)

Flange Heaters Optional Heaters

STFX, Small Tank and LTFX Large Tank STFX, LTFX and RSTO Immers ion Heaters Flange Heaters allow tank heating elements are available with explosion resistant electrical to be changed without draining the tank. They enclosures and/or adapter flanges in place of provids low watt density heeating over a large tile adapter box. surface area while providing precise tempera­ tu re control.

Allow lor Tank ,.-

-~-l r-- - Auld Level .Jfil.

' ~$ WARNING - In hazardous areas, pipe surfaces could achieve temperatures high Allow lor Tank enough to cause auto-ignition of hazardous lnSUYhOO and BolnOQ -1 materials present. Consult Article 500 of the 36' Min. Element FlUid National Electrical Code for further information r- Removal DIStance 1 level on the maximum allowable temperatures for a ~Jtflll:llj].fl1l.flilll}, f if m:.. specific application. Open·CoUEtemeniS - ~ ModellTFX ... ,-...- ...- Tank

STFX 1 - 25 3.4- 85 0-29

LTFX 4 - 240 13.6- 816 0 -30

0-31 Packaged Systems

Ordering Guidelines Open Coil Heaters

Ordering Model large Tank Healing Systems Info mwti o 11 OCE Open Coil Element To Order­ Code length (nearest Ft.) Specify model, 19 19 volts, phase, kW, ~------Code Wattage PCN (where available) and 125 12.5 kW (use actual kilowatt in three digits i.e. 5 kW=050 or 0.5 kW=005) options desired. Code Pipe Size (Schedule 40) Complete model 2 2' NPS number using the 3 3' NPS matrix provided. Code Voltage 20 208 24 240 38 380 41 415 48 480 57 575 Code Phase 1 Single 3 Three I OCE 19 125 3 24 3 Typical Model Number

Note - NEMA 4 or 4X terminal enclosure kit is available for field installation by contacting your local Chromalox Sales office.

C:hronnalox ® ------~•l·fEfl·• Packaged Systems

STFX Small Tank Flange Heater (cont'd)

Steel Flange, 304 Stai11less Steel applicatiom Model Specifications - 40 wlitr (6.2 w!CIIr) ApplicatiollS

Applicatiou Recommmded wlirr w/in1 Oil I (w/cm1) I Wate r ------40 (6.2) Water or Water/Glycol Mix Light Weight 20 (3.1) Mildly Corrosive Medium Weight 10 (1.6) Severely Corrosive Heavy Weight 5 (1) ····------·------·-- Note: To maximize heater life, the unit selection requires critical engineering judgement by the plant engineer in the selection of proper heater materials and watt density.

C:hronnalox ® ------~•&·11'1' ackaged Systems

STFX Small Tank Flange Heater (cont'd)

Orderi11g bifonllatiou

To Order- Complete model number using the matri x provided. Model Small Tank Heating Systems STFX Small Tank Flange Heater Code Thermowell Material S 304 Stainless Steel I lncoloy 800 X Other Material Code Flange Material (Blank) Carbon Steel s 304 Stainless Steel X Other Materi al

01 Five 02 Six 03 Seven 04 (.;OOe wanage 004P5 4.5 kW (use actual kilowatt in three digits) Code Terminal Housing Style E4 Moisture Resi stant E2 Explosion I Moisture Resistant Code Non-Standard Feature (Blank) Catalog PCN item XX Custom Feature Code Voltage 208 208V 240 240V 380 380V 415 415 v 480 480V 600 600V Code Number of circuits 1 One 3 Three 2 Two 4 Four Code Phase 1P Single Phase 3P Three Phase Code Kilowatts 4.5 kW

STFX s s -03 -004P5 -E4 480V 1 -3P 4.5kW Typtcal Model Number Example of Final Model Description: STFXSS-03-004PS·E4 480V 1·3P 4.5kW

Note - Shaded sections of the model build table are not a finite list. Items such as Number of Tubes, Length, Wattage, and Voltage should be adjusted to match design. C:hronnalox ® ------~•l·lfllf' Packaged Systems

Replaceable Type "J" Open-Coil (OC E) LTFX Thermocouple in a Thermowell for Removeable Heating Elements Overtemperature Sensing Large Tank Flange Heater (cont'd)

2" or 3" Schedule 40 Pipe 150# ANS I Flange Connection

Note: Explosion Resistant Control Panels are available. t-=::~~~....:;:.,;-=-=,___,r-...,:.::'--lf--...:.="-+--=--+-.:...._-l----'~--1--'----'""-".::...._-+-....:..--+-.::;_-lf----'-.::;_----l However, installing the control r.:;~~~~-=-=':-lf--~:-lf--~~+-~-+-:----t----'~--t--7::---''=!:,--t-7--+-7:--lf---=::---l panel outside the hazardous lo­ ~~~~~~§...-lf-~~f-~?--l-..:?--4-!..-+---!~-+_g.,....:..J~.!!._~-~--t-~-lf--5i!----lcat ion may offer significant cost H=;;~~g~~Hf-~~f--~~+-+-+---:~+~~-+..!?:~~~--4-~-4-f:...-lf----:-g._-l savings. Please refer to section ~~~~~~§...-ll-~~f-~?--l-..:?--4---.!§-+...... ::!¥¥-+...!!:!..,-:.~¥!!..~-..:!---t-£_-lf-...... !..!L---I 'H' of the catalog for available panel options.

Optiounl Accessories PCN I Description 308355 12" - Type • J" TIC for customer install 308064 12" - RTD for customer install 308670 Thermowell for TIC or RTD 327783 Type J Extension wire 100ft. 308873 Type J Extension wire 200 ft. 327791 Type J Extension wire 500 ft. 308881 TvPe J Extension wire 1000 ft. 308144 RTD Extension wire 50 ft. 308152 RTD Extension wire 200 ft. 308160 RTD Extension wire 1000 ft. 073139-031 Universal Support Stand (Stainless Steel) 073139-032 Universal Support Stand (Carbon SteeQ ,. Note- Chromalox adjustable support stand helps to ensure ease of installation and minimal on-site fabrication. Chromalox®______ac aged Systems

LTFX Large Tank Flange Heater (cont'd.)

Certificatio11s

E4 Moisture Resistant Enclosure Certifications North America Canadian Eu ropean International I Designation(s) I Designation(s) I Designalion(s) I Designation(s) Rating NEMA4 NEMA4 IP66 IP66 Agency(s) Manufacturers @· CE declaration c us ® ®· Manufacturers declaration

E2 Moisture ResistanVExplosion Proof Enclosure Certifications North America Canadian European International I Deslgnation(s) I Designation(s) I Designation(s) I Deslgnation(s) Rating Explosion Explosion Explosion Explosion Resistant Resistant Resistant Resistant Agency(s) CSAus CSA ATEX IECEx Ratings· Class I, Div. 1 Groups Class I, Div. 1 Groups Ex d IIBtH2 Gb B. C& D B. C & D ( Eo359 Tl to T6 © 11 2G Ex d IIBt H2 Gb T1 to T6 Class II, Div. 1 Class II, Div. 1 IP66 IP66 Groups E. F & G Groups E. F & G Class I Zone 1 Class I Zone 1 AEx d Ex d liB+ H2 Gb liB+ H2 Gb T1toT6 Tl toT6 -so·c < Ta < t60'C 'Note: Temps over T3 (200'C) require stand-offs for third-party listing. Refer to IECEx and ATEX certificates fo r sta nd -o ff dimensions.

C:hronnalox ® ------~•E·fE'I• ac age ys ems

RSTO-B Unitary Electric Immersion Heater

• 15 -26 Ft. Immersed Length

• 15-72 kW (51 -246 Mbh)

• 240 and 480V, Three Phase (600V Available) Feahtres • 3 W/Jn2 on Pipe (Heating) Surface Easy Maintenance and Service - Flexible and switches. Electronic process temperature • Weather Proof Electrical OCE elements can be bent in a vertical plane control mounted in door and accessible from Enclosure on a 12 inch minimum radius and require only outside the enclosure. Optional time clock. 3 feet for installation or removal. • Holding Temperatures 175 - 375°F Optional Explosion Resistant Electrical Weather Proof Electrical Enclosure com­ (Optional Control 20 - 120°F) Enclosures for hazardous locations, special pletely wired with safety interlocked ci rcuit co nstruction material, stainless steel and breaker, overtemperature controls, pilot lights others.

Applications Specificatious a11d Ordering Information Chromalox RSTO and RST Unitary Electric Immersion Heaters provide low watt density heating over a large heated surface with precise temperature control for such materials as asphalt, fuel oil, pitch and tar, liquid sugar, molasses, lube oils, linseed oil and other heat sensitive materials. Unitary heaters are installed in large tanks above or below ground (requires access to one tank end). RSTO immersion heaters are recommended for general purpose applications and cramped locati ons. Open coil (OCE) heating elements are housed in 3' Schedule 40 NPS steel pipe and are removable without draining the tank. A liquid-tight adapter box5 is provided for welding the heater assembly to the tank header.

Stock Status: S =stock NS = non-stock To Order-Specify model, volts, phase, kW, overall immersed "B" length and quantity. 1. Heated length is 4 • shorter than B dimension. 2. Other voltages available, contact your Local Chromalox Sales office. 3. Suffix "T" indicates optional 7 day 24 hour time clock. Suffix "F" indicates flange mounting instead of adapter box. 4. Special ratings, immersion lengths and configurations available. 5. Optional adapter flange available in place of adapter box. Complete details and dimensions of adapter box, adapter flange and enclosures are available from your Local Chromalox Sales office.

C:hronnalox®------4'11·filijM ac age ys ems

~e SHO c us Suction Heater - Asphalt Dimensions (lucbes) SHO & Fuel Oil Applications Outlet for Horizontal 18" -150 Lb. 3*- 150 Lb . Fig. Installations Mating Fig. ~ J A ~~

• 1 0" Carbon Steel Pipe Body and Heater Flange, 150 Lb Construction (Pipe Sizes from 5 - 20" available) ©)~~~Inl~et ~- B ~ 18" 150 Lb ANSI B16.5 Tank Mounting Flange Matched to 10" Applicatious Features Pipe Body (Mating Flanges from Heating of viscous materials, in large storage Termin al En closure - SHO circulation heat­ 10 - 30" available) tanks, to pumping temperatures. Maintaining ers are designed to be installed outdoors in an entire tank of viscous fluids such as fuel exposed areas. Enclosures are designed to be 30 - 40kW Standard (1 0 - 200kW oil or asphalt at pumping temperatures is very Moisture Resistant or Moisture and Explosion available) costly. In many applications it is not practical Resistant. or economical because th e tan ks are located Low Watt Den sity Elements make the • 240 and 480V, Three Phase (Up underground or are not insulated. to 600V available) heaters safe to use on most viscous liquids. Type SHO Suction Oil Heaters are a cost­ Carbonization is minimized. • Moisture Resistant and Moisture effective solution to this problem. Suction Vessel - Pipe body and nozzles are galva­ / Explosion Resistant Terminal heaters are specifically designed to heat only nized ASTM A53B carbon steel pipe. Heater that amount of material that is to be pumped Enclosure and mounting flanges are ANSI 816.5 150 Lb from a large storage tank. The outlet nozzle galvanized carbon steel. Asse mbly provided • 0.475" Dia. Steel Sheath Low is attached to the pump suction. The heater with therm al insulation and painted sheet heats the material inside the heater pipe body Watt Density Elements (5 Wlln2) metal jacket. which is then drawn through the heater into the suction side of the pump. This technique Thermostats and High Limit Controls- SHO saves substantial energy costs since it is not suction heaters should be provided with Class I, Division 1, Groups B,C,D necessary to heat the entire contents of the temperature controls to control fluid outlet tank to draw off relatively small amounts of te mperatures and limit internal tempera- Class II, Division 1, Groups E,F,G viscous materials. tures under abnormal or no-flow conditions. Class Il l, Division 1 Depending on customer specifications, SHO Complete weather-proof construction makes Class I, Zone 1 heaters may be supplied with factory equipped these heaters perfect for installation in large AR therm ostats, high limit cutouts or other outdoor storage tanks. Large heater inlet pro­ AEx d IIB+A2 T1-T6 Chromalox controls. vides smooth, full-flow through the heater. Control Panels- Integral or remote mounted control panels with electronic controls and solid state (SCR) or co ntactor power con­ trollers can be provided using virtually any combination of control devices. Consult the Controls section for details. Specificatious aud Orderiug bifonnatiou

More Information is Available Online CD on Tank Heating. Stock Status: S =stock NS =non-stock Bookmark Your Browser to To Order-specify model, volts, phase, kW, PCN and quantity. www.chromalox.com Note - It is recommended that a butterfly valve with a worm gear assembly be installed on the intake flange for ease of maintenance or replacement of the heater and Select Manuals. assembly. Contact your Local Chromalox Sales office for assistance. Chromalox®______c age ys ems

Steam Boilers Selection Guidelines

With the pressure and capacity known, con- Steam Boilers- Selection Guideliues tinue the selection process by consulting the Maximum I Maximum I detailed product pages for the models listed in Pressure Temp. th e accompanying table. (psig) (•F) kW I Descripti on I Mode l I Page 90 331 3-15 Compact CMB D-45 90 331 16-20 Special CAS 0-46 90 331 6- 180 Vertical CES-B D-47 90 331 6- 180 Stainless Steel CSSB-A D-49 135 358 150- 1,620 High Capacity CHS 0-51 235 401 6- 180 Medium Pressure CHPES-A D-53 Optional EQuipment D-55 Custom Engineering & Manufacturing D-58

Adva11tages Ch romalox Packaged Electric Boilers of1er the Simple, Safe Operation- Most electric advantage of electricity as th e heat source to boilers can be operated by custodial personnel provide low or high pressure steam or hot wa­ with a minimum of training. ter. Building and installation costs are reduced Fast Start Up and Recovery- Boilers can substantially over fuel fired boilers since fuel be turned on and be up to pressure within tanks, chimneys, flue s, ven ts and complex minutes. Long warm up times or co mplicated piping required fo r foss il fue l fired boil ers are start up proced ures are unnecessary. eliminated. Minimal Maintenance - Electric boilers Packaged boilers comply with all the requi re­ only requi re a periodic or daily "blow down" ments of relevant UL and GSA Standards and to maintain their efficiency. (An optional auto­ and the Canadian Registration (CRN). Boilers matic blow down system ca n be purchased to are completely assembled and tested under ensure continuous reliability of operating conditions to rigid quality standards planned maintenance.) prior to release fo r shipment. Chromalox Reduced Operating Costs- Electric boilers electric boilers are ready to install and need can provide steam "on demand" using auto­ only a water feed source and an electric power matically contro ll ed electric power. Operating hook-up to produce fast , economical high­ costs can be controlled by reducing or elimi­ quality steam. Energy conversion efficiencies nating "idling" or "standby" operation when approaching 100% are possible. th e is not needed. Cleanliness- No fumes or products of combustion. Boilers may be installed in alcoves, under counters or in other restricted spaces.

Electric Hot Wlzter & Steam Boilers - General Specificatiom

I Operating I Temf. I Vesse l Pressure I Connection Model I Description Pressure (psig) (•F I kW I Mbh2 Rating (psig) Type CMB Compact Steam Boiler 0-90 212 -331 3- 15 10 - 51 100 NPT CES-B Vertical Steam Boiler 0-90 212 - 331 6 - 180 21 - 614 100 NPT CAS Special Steam Boiler 0 -90 212- 331 16 - 20 55-68 100 NPT CSSB-A Stainless Steel Steam Boiler 0 - 90 212-331 6 - 180 21 -614 100 NPT CHPES-A Medium Pressure Vertical Steam Boiler 0 -235 212 - 401 6 - 180 21 -614 250 NPT CHS High Capacity Horizontal Steam Boiler 0-135 212- 358 150 - 1,620 512-5,527 150 NPT and Flanged GCH' Steam 0-150 212 - 800 1 - 350 3-1 ,194 150 NPT or Flanaed Notes - 1. See Circulation Heater section. 2. Mbh is ASME & ANSI standard for thousand British thermal units per hour.

C:hronnalox ® ------~•l·l#ilf' ac age ystems

CMB Compact Dimeusions (Inches) Steam Boiler CMB-3 --).. 1/2" IPS Inl ei and 1/4" 1PS Oullel • Steam Pressures to 90 psig

• Steam Capacity (9 - 45 Lbs!Hr @ 0 - 90 psig) H I • 3-15kW(10-51Mbh)

• 120, 208, 240 and 480 Volt, 1 & 3 Phase (600V Available) Feattn·es W- • ASME Section I Pressure Vessel Pressure/Temperature Control easily adjusts Carbon Steel Code "M" operating pressure. Pi lot light indicates when CMB-6 through -15 (1 00 psi g) (CRN Available) bo iler is on and element is heatin g. 1/2" 1PS Steam Pressure Gauge provides visual indica­ Inlet and 0.430" Dia. Copper Sheath tion of steam pressure. Outlet Heating Elements with Run Dry Protection Mechanical Float Valve Water Feeder can be connected directly to water main, eliminating • Automatic Mechanical Float complicated feed water piping3• Valve Water Feeder with Inlet Water Level Sight Glass allows constant visual 3 Check Valve observation of water level in the generator. Electronic Low Water Cutoff Safe, Reliable Operation is assured by a (Single Probe) separate low water cutoff that shuts down the generator if it accidentally runs low on water. • Water Level Sight Glass and Blow Down Drain Valve

• Pressure Gauge (0 - 160 psig)

ASME Safety Relief Valve

Applications

CMB Low Pressure Steam Generator­ Delivers 9 to 45 lbs. of steam per hour at 0 - 90 psig, and is used in many manufactur­ ing processes. The CMB's small size and small capacity make it an ideal "point of use" steam source in industrial plants, computer rooms, laboratories, hospitals, jewelry stores, steam rooms and other spot heating applica­ tions. The CMB is also ideal for stand-by operations which require small amounts of steam or humidification during off season periods when the main plant boiler may be shut down. Stock Status: S = stock NS =non-stock To Order-Specify model, volts, phase, kW and PCN. All CMB steam generators are inspected to rigid quality standards. They are factory 1. At 212•F with SQ•F feed water. 2. Other voltages are available. Contact your Local Chromalox Sales office. tested under operating conditions and are 3. For proper operation, the automatic water feed control unit requires a water supply ready to operate. pressure of 10 psig greater than the operating pressure of the steam generator. Chromalox®------am age ys ems

CES-B ® Vertical Steam Boiler ~· • Steam Pressures to 135 psig 0 • Steam Capacity (18 - 542 Lbs/Hr @ 0 - 135 psig) @ • 6- 180 kW (21 - 614 Mbh)

• 208, 240 and 480 Volt, Features Low or High Pressure Water Feed or Conden ­ 1 & 3 Phase (600 V Available) sate Return System for feed. CES-B Stock Steam Boilers are Trimmed at 100 psig for operation to 90 psig - They are Heavy Duty Vacuum Breaker prevents • ASME Section I Pressure Vessel also available (on order) with 15, 30, 50 and siphoning of condensate in condensate return Carbon Steel Code "M" 150 psig trim. Boilers tri mmed at 150 psig systems. (100 psig) (CAN Available) can be operated up to 135 psig correspond­ Automatic Blow Down System eliminates daily ing to 353·F. Boilers trimmed at 150 psig use manual blow-down maintenance. • 0.430 Dia. Copper Sheath a special ASME Section I, Code "S" pressure Heating Elements vessel. All catalog CES boilers are UL Listed Blow Down Separator for blow down of a and CSA Certified. boiler where steam and hot water cannot be • One or Two Operating Controls discharged directly into a drain. Manual Reset High Limit Optioual Eqttipmeut Electronic Water Level Control with automatic • Mechanical Float Water Feed Auxiliary Electronic Low Water Cutoff ­ water feed and low water cutoff (dual probe). This option is requ ired by some state or local Control with Low Water Cutoff Proportional Control with electronic solid state boiler codes. sequencer for modulated pressure co ntro l. • Pressure Gauge, Water Level Sight Glass and Blow Down 7ypical CES-B Con.stmction Drain Valve(s) _,..-..,.--- Opera ling Pressure Controt(s) • ASME Safety Relief Valve Steam Pressure Gauge Pressure Reifel • Optional Transformer Manu al Reset High Lim it Control

ASME Nameplate (under

Applicatious

CES-B Medium Capacity Steam Boilers are sized to match the most common requi re­ Automatic Slowd own ~N.J~ r- r·aoaaType Pump Control Control (Optional) and low Water Culell ments for steam in many commercial applica­ ti ons, laboratories, hospitals and industrial Power Fuses, Conlactors plants. CES-B boilers are ideal for stand-by & Terminal Blocks operations requiring high pressure steam in remote areas of an industrial plant which Carbon Steel ASME might incur excessive pi pe losses or expensive Pressure Vessel piping costs to supply from a central steam Heating Elements supply. They are ideal for off season periods Insula lion when steam is needed for critical processes or humidification when the main boiler is shut down. Automatic Bl owdown Valve (Optional) Drain/Biowdown Valves

Chromalox®______Note - A water feed system_ or condensate___ return system_ ____ is required. See Optiona_ l Equipme nt. Packaged Systems

CSSB-A Stainless Steel Vertical Steam Boiler

• Steam Pressures to 90 psig

• Steam Capacity (18 - 542 Lbs/Hr @ 0 - 90 psig)

• 6- 180 kW (21 -614 Mbh)

• 208, 240 and 480 Volt, 1 & 3 Phase (600V Available)

• ASME Section I Pressure Vessel Stainless Steel Code " M" (1 00 psi g) (CRN Available)

• 0.430 Dia. INCOLOY~ Sheath Featm·es Optiomd Equipmeut Heating Elements Stainless Steel Construction- Pressure All optional equipment (except blow down • One or Two Operating Controls vessel and all wetted parts are made of 304 separator) is available in stainless steel con­ Manual Reset High Limit stainless steel for ope ration with pure water. struction for compatibility with the basic boiler. Type 316 stainless steel construction is avail­ able. Auxiliary low Water Cutoff uses vertical ball • Float Water Feed Control float with electronic control. This option is with Low Water Cutoff Low Water Cutoff and Level Control - Float required by some state or local boiler codes. type constructed of stainless steel automati­ • Pressure Gauge, Water Level ca lly maintains correct water level in the boiler Proportional Control with electronic solid state Sight Glass and Blow Down and shuts down the boiler if the level drops sequencer for modulated pressure control. Drain Valve(s) be low safe operating limits. low or High Pressure Water Feed System (Required) fo r mounting on boiler or remote • ASME Safety Relief Valve Operating Controls- Al l stai nless steel pres­ sure controls provide accurate regulation of installation. steam pressure. Heavy Duty Vacuum Breaker prevents siphon­ ing of condensate from condensate return Applicatio1ls High Pressure Limit Control -All stainless steel manual reset pressure limit control shuts systems. CSSB All Stainless Steel Steam Boilers are down boiler if operating pressure exceeds set Automatic Blow Down System eliminates need specifically designed for use where the purity point. for daily manual blow-down maintenance. of the heating fluid must be maintained. Water level Sight Glass- Furnished with Typical applications include sterilizers and Blow Down Separator for blow down of a stainless steel valves, provides for constant autoclaves in research, biological and phar­ boiler where steam and hot water cannot be visual observa tion of the water level in the maceutical laboratories and humidification discharged directly into a drain. Blow down boiler. equipment for the electronics industry (solid sepa rato r uses city water for cooling. state substrates). Pressure Gauge, Safety Valve , Drain and CAUTION - The use of chlorina ted or regula r Blow Down Valves are constructed of stain­ CSSB boilers utilize de-ionized, deminerali zed tap water in stainless steel boilers is specifi­ less steel for compatibility with basic boiler. or distilled water to provide pure steam, free cally prohibited by the ASME Code. The feed of minerals or undesirable chemical addi­ CSSB Steam Boilers are Trimmed at 100 water for CSSB boilers must be distilled, tives. Pure steam eliminates the possibility of psig for operation to 90 psig and come de-ionized or demineralized water with a carry over of contaminants into the process. complete, factory tested and ready to operate. minimum specific resistivity of 1 megohm/ Boilers are available (on ord er) with 15, 30 em. Fai lure to use the correc t type of water will Note - A water feed system supplying dis­ and 50 psig. All catalog CSSB boilers are UL damage the equipment and void the factory tilled, de-ionized or demineralized water Listed. warranty. is required on all CSSB boilers. (See Caution note.)

C:hronnalox ® ------~•l·ll; ijl·• CHS ® High Capacity Horizontal Steam Boiler 0 ~- Steam Pressures to 135 psig

• Steam Capacity (452 - 4,882 Lbs/Hr @ 0 - 135 psig)

• 150-1,620kW (512- 5,527 Mbh)

• 208, 240 and 480 Volt, 1 & 3 Phase (600V Available)

• ASME Section I Pressure Applicatiolls long life Heating Elements - Conserva· Vessel Carbon Steel Code " S" lively rated flange mounted 0.475" dia. copper (150 psig) (CAN Available) CHS High Capacity Steam Boilers are unique· sheath heating elements provide uniform ly designed for larger commercial applications, water circulation and long life. laboratories, hospitals and industrial plants. • 0.475 Dia. Copper Sheath Full Port Blow Down Drain Va lves- Two Heating Elements CHS boilers are ideal for stand-by operations requiring high pressure steam in remote heavy duty gate or ball valves connected in areas of an industrial plant which might incur series for high pressure are supplied for boiler • Two or Three Operating blow down. Controls with Contactor Panels excessive pipe losses or expensive piping costs to supply from a central steam supply. (150 - 300 kW) Integral El ectri ca l Controls and Power Panels CHS boilers are particularly suited for use in with fuses and contactors mounted in heavy off season periods whe n steam is needed for • Proportional Operating Control gauge control cabinet(s) with hinged doors critical processes or humidification and the and captive fasteners. with Sequencer and Contactor main boiler is shut down. Panels (above 300 kW) Co ntrol Circuits are 120V/1/60 Hz (Standard) Featm·es - 220V/1 /50 Hz control circuits are available • Manual Reset High Limit for export boilers. Transformers are optional. Control with Stop at 90% of CHS Stock Boilers are Trimmed at 150 psig Safety Valve Setting for operation up to 135 psig corresponding to Manual On-Off Switch allows boiler control 353°F. They are also available with 15, 30, 50 and power circuits to be shut down locally. and 100 psig trim. All catalog CHS boilers are • Mechanical Float Water Feed Pilot light visually indicates when boiler UL Listed. Control with Low Water Cutoff control circuit is energized and th e boiler is Water Feed (Pump) Control and Low Water operating. • Auxiliary Low Water Cutoff Cutoff (McDonnell Miller #1 57) automatically Fiberglase Insulation material around the (Solid State) Control maintains correct water level and shuts off the entire pressure vessel minimizes heat loss and boiler when the water level in the boiler drops helps reduce energy costs. • Pressure Gauge, Water Level below safe limits. Sight Glass and Double Blow Down Drain Valves Water Level Sight Gla ss allows for constant visual observation of the water level in the Plztmbi11g Comzectio11s boiler during operation. Water Steam • ASME Safety Relief Valve Inlet I Outlet (Two on Boilers Over 1,1 00 kW) Auxiliary l ow Water Cutoff- Solid state Boiler I (NPT) (150 Lb . Flanged) control board with low voltage probe provides CHS 150. 420 4 backup protection for low water level in the CHS 495·945 I 1 I 6' CHS 1000.1620 I 1-1/2 I 6' boiler. ,.. A water feed or condensate return Steam Pre ssure Gauge with a range to 250 system is required on all CHS boilers. See Optional Equipment. psig provided for visual indication of steam pressure.

C:hronnalox ® ------~•11·1111' Packaged Systems

CHPES-A ® Medium Pressure Vertical Steam Boiler 0 • Steam Pressures to 235 psig ~- • Steam Capacity (18 - 542 Lbs/Hr @ 0 - 235 psig)

• 6-180 kW (21 - 614 Mbh)

• 208, 240 and 480 Volt, 1 & 3 Phase (600V Available)

• ASME Section I Pressure Vessel Carbon Steel Code " S" (250 psig) (CAN Available)

• 0.430 Dia. Copper Sheath Heating Elements CHPES Boi lers are Trimmed at 250 psig for Optionnl Equipment • One or Two Operating Controls operation up to 235 psig , come complete, Auxiliary Electronic Low Water Cutoff- Solid Manual Reset High Limit factory tested and ready to operate. CHPES boilers are UL Listed. State control board with low voltage probe provides backup protection for low water level • Mechanical Float Water Feed Fentttres in the boiler. This option is requi red by some Control with Low Water Cutoff state or local boiler codes. 250 Lb Medium Pressure Construction • Pressure Gauge, Water Level - Pressure vessel is manufactured to the Proportional Control wi th electronic solid state Sight Glass and Blow Down requirements of ASME Section I and code sequencer for modulated pressure control. Drain Valve(s) stamped "S". Electronic Level Control with automatic water feed and low water cutoff (dual probe). Low • ASME Safety Relief Valve Water Feed (Pump) Control and Low Water Cutoff (McD onn ell Miller #194) automatically cost alternative to mechanical float type water maintains correct water level and shuts off the feed control and low water cutoff. boiler when the water level in the boiler drops High Pressure Water Feed System tor remote below sa fe limits. Applicntions installation. Operating Controls- Pressure control(s} CHPES Medium Pressure Steam Boilers Condensate Return System for recovery of provide accurate regulation of steam pres­ steam condensate tor boiler water teed. can be used wherever steam and process sure. temperatures up to 400°F are req uired. Heavy Duty Vacuum Breaker prevents High Limit Pressure Control- Manual reset CHPES boilers produce steam at pressures siphoning of condensate in condensate return pressure limit control shuts down boiler if and temperatures considerably higher than systems. CES models which are limited to 135 psig maximum operating pressu re is exceeded. and 359°F. Automatic Blow Down System eliminates need Water Level Sight Glass- Provides fo r for daily manual blow-down maintenance. CHPES Boilers are Ideal for stand-by opera­ constant vis ual observati on of the water level tions requiring steam in remote areas of an in the boiler. Blow Down Separator for blow down of a industrial plant which might incur excessive boiler where steam and hot water can not be Steam Pressure Gauge with a range to 600 discharged directly into a drain. pipe losses or expensive piping costs to psig provided for visual indication of steam supply from a central steam supply. They are pressure. Note - A water teed or condensate return ideal for off season pe riods when steam is system is required on all CHPES needed for critical processes when the main Drain and Blow Down Valves- Facili­ boilers. See Optional Equipment. boiler is shut down. tate clea ning the boiler during blow down seq uen ce.

C:hronnalox ® ------1•~·1111' ackaged Systems

ES38038V Condensate CBS-I Blow Down Separator ­ Steam Boilers Return System Dimensious (Inches) Optional Equipment

Condensate Return Systems Chromalox condensate return systems are used wherever condensed steam can be collected for reuse in the boiler. Significant en­ ergy can be saved by returning hot condensate to the boiler for feed water. The condensed water is free from corroding minerals and contains a substantial amount of heat energy CondellSate Return System Selectiou which does not have to be rep lenished. CAUTION - Wh en a condensate system is used, a vacuum breaker must always be in­ stalled on the boiler to prevent the boiler from flooding during shut down. low and Medium Pressure Condensate Re­ turn Systems (150 psig maximum). Chromal­ ox condensate return systems (except model HPCS 3003) are designed fo r use with steam boilers operating up to 150 psig steam pres­ sures. The condensate systems consist of an Stock Status: S = stock NS = non-stock 11 gauge steel tank, motor, pump, float valve, To Order - Specify model number of condensate system, boiler model number, sight glass and associated plumbing. A 1/2" volts, phase, kW, PCN if applicable, and quantity. inlet is located on the tank for connection to a Note- local water supply for make up water. A "ve nt" A. Connections (NPT): Pump Out = 1' , Tank Return = 1-1/4" B. All motors can operate on 208V. Systems for boilers larger than 810 kW have is located on the top of the tank and is open horizontal tanks. Use ES38084V for all CES boilers with 135 trim. to the atmosphere. The "return" connection is plumbed to the trapped condensate return line Blow Dowu Separators from the process. Blow Down Separator Selecti01l Many state and municipal boiler codes do not The condensate tank has an internal ball check permit discharge of boiler blow down directly valve, a float and float arm which mechani­ into city sewers. Chromalox blow down sepa­ cally opens a valve, allowing make up water rators separate liquid from vapor during blow ~~__,.;:;.,....=~~"'*':-=+:...,_-+-=_.:.:.,:"'+"'==+-~~ to enter the tan k as the original supply is down and prevent the dangerous discharge depleted. The outlet of the pump is plumbed of live steam down city drains. The separator to the boiler water inlet check valve. Th e pump accepts water and flash steam from the boiler motor is wired to the boiler feed water control blow down, reducing temperatures and pres­ or motor starter. No further adjustments and/ Vtzcuum Brettker Systems or plumbing are requ ired other than plumbing sures to safe levels for subsequent discharge the condensate tank drain and drain valve to a to the sewer. After boiler shut down, the steam inside the proper waste connection. The separator is kept half full of cold water vessel condenses as the shell cools. This creates a vacuum which will siphon water into High Pressure Condensate Return Sys- before each blow down. The design utilizes the boiler from th e water feed or co ndensate tems (250 psig maximum). The Chromalox a water seal at the outlet which permits the HPCS3003 high pressure (250 psig maxi­ system to introduce cold water from the bot­ return system, flooding the boiler. A vacuum mum) condensate return system is specifically tom to mix with the hot water and boiler steam breaker permits outside air to enter into the designed for use with the CH PES-6 through blow down inside the separator. Flash steam shell to relieve the vacuum, thus prevent- 180 kW boilers whenever condensate is to be is absorbed by the cold water and allowed to ing excess water from being drawn into th e returned for reuse. pass to the outside through a vent. Chromalox vessel. The vacuum breaker consists of a blow down separator CBS is built and stamped valve with a spring loaded disc and associated The high pressure condensate return system piping, factory plumbed to the boiler. They can consists of a 30 gallon tank with an internal to Section VII I of the ASME Code. be used on all Chromalox boilers. make up water float valve, a 3 Hp three phase Bl ow down separators requ ire only plumbing motor (motor voltage will match the boiler's from the boiler blow down, hook-up to a cold }1/zcrmm Breaker Selectiou voltage), a special high-pressure pump and water supply line and connection to a drain. a sight glass. A motor starter and fuses can No electrical connections are required. Order WithUse IPressure Max. I be supplied as an option. Installation requi res options include a 0 - 30 psig pressure gauge, Model Boiler (psig) PCN wiring and field plumbing to the boiler with ES89369 minimum 1/2' NPT piping rated at 250 psig. 0- 200°F temperature gauge and a water sight glass gauge assembly. ES89369SS HPES89369 C:hronnalox®------4'11•imf'l ac aged Systems

Steam Boilers Circular sequencer operation and staging can n·mzsformers Optional Equipment be visualized by the referring to following illustration. The "0 " represents an element Transformers for control circuits and pump (cont'd) bundle in the de-energized position. The ... .. motors can be supplied to eliminate the need represents an element bundle which has been fo r separate 120 Vac power for control cir­ Elecn·ic Element Sequencers energized by the sequencer. cuits. Transformer primary voltage wi ll match boiler power voltage. Transformer second­ Sequencers are designed to apply power to VisualiZiltion ofProgressive Ci1·culnr ary voltage will be 120 Vac unless otherwise large kW boilers in progressive stages. Auto­ Sequencing specified. matic sequencing provides accurate and cost effective control, saving energy and minimiz­ Progression -> -> -> Transformer Selection- To select transform­ ing wear and tear on electrical components. er size. simply find the sum of all component Sequencing extends the life of the individual kVA requirements to be powered by the trans­ heating elements by rotating the load evenly former. A CES-72A with ES38083V condensate across all element bundles. Reacting to an in­ return system and 810158 automatic blow put signal from a factory installed proportional down system would require: pressure control, the sequencer energizes Basic Boiler 1/4 kVA and de-energizes each heating element circuit 0 = Stage "OFF" • = Stage "ON" ES38083V 3/4 kVA through individual power contactors. The se­ 810158 .1LZ.J0lA quencer programs a delay before start up and Total Required 1-112 kVA between each subsequent step to eliminate Electronic Auxiliary power surges. Once up to power and pressure, Factory Mounted & Wired the load is "fine-tuned" for close pressure Lorv Wlzter Cutoff Tra 11 sfo rmer control, with a minimum of over-shoot or droop. Each sequencer is pre-set to match An auxiliary low water cutoff can be used as the specific boiler and system requirements. a safe and reliable backup to the primary low In case of power interruption, the sequencer water cutoff control and is required by some restarts with all steps de-energized. Electronic state and local boiler codes. Auxiliary low wa­ solid state sequencers are available with up ter cutoff is provided by an electronic device to 20 steps or stages for efficient operation of with a solid state amplifier and a solid state any size Chromalox boiler. switch for operating the mechanical control relay. Operation is accomplished by sensing Electronic Sequencer Operation- Solid a minute current flow between submerged n·ansformer Sizing- Basic Boiler state progressive sequencers provide accurate contact probe and the boiler shell. When water electronic control of multistage loads of the level falls below safe operating level, the boiler Min. type used in Chromalox steam boilers. They is shut down. Auxiliary low water cutoffs are Basic Bo iler kVA Requi red CMB 6, 15 1/4 feature progressive circular sequencing standard on all CHS type steam boilers. CES CHPES CSSB 6-72 1/4 (first-on, first-off) which equalizes the operat­ CES 100-180, CHPES 100 1/2 ing time of each load and co ntactor. The con­ CHS 150-420 1/2 trol gives visual indication of each energized Elech·onic Level Control CHS 495-630 3/4 stage by means of integral solid state light CHS 720-1620 1 , Minimum size transformer offered emitting diodes. In the event of power inter­ is 1.0 kVA. ruption, all heating elements are immediately de-energized for safety. When power resumes, the control will restage the loads one at a time. Trausformer Sizitzg-Option Loading

'II I Option Electrouic Solid State Sequencer Water Feed Systems ES99117 ISSl. HS99111 7 1/4 (Control Board) ES38002 ISSl. ES38020ISS\ 3/4 Note -For single probe auxiliary low water ES99157 1 cutoff (shown with plug-in control relay). HS38021 ES38020HP 1-1/2 Automatic Blow Down Systems Note -Electronic auxiliary low water cutoffs 81015A 8 SS I 1/2 are not appropriate for use with CSSB or other 811 15 81215 I 1/2 boilers using demineralized, de-ionized or 81025 I 1 distilled water. Contact your Local Ch romalox Condensate Return Systems Sales office for information on available stain­ ES38083V 3/4 less steel low water float switches fo r use with ES38084V 1 All 3-phase Condensate electronic auxiliary low water cutoffs. Return Systems (3 pole 1/4 motor starter required) C:hronnalox ® ------~•l·lfiDI' HACS Air Temperature Control Electric Heating System

· Portable, Forced Air Temperature Control System • 50, 100, and 150 kW Heating Capacity Descriptiou Advmztages · 480 V, 3 Phase, 60 Hz (600V Available) Chromalox Air Temperatu re Control Systems • Ch romalox Electric Heating Systems are provide durable, accurate temperature control environmentally friend ly, 100% efficient, and • Corrosion Resistant Painted for large capacity temporary heating applica­ produce zero emissions. Steel Construction tions. Welded steel construction, tubular elements, and industrial fan offer superior • Electrically generated heat produces no · Heavy Duty 0.475" Dia. durability and performance under heavy us­ moisture, and therefore no humidity. INCOLOY~ Sheath Tubular age and rough environments. • INCOLOY~ sheathed tubular heating ele· Elements ments provide long life and durability during Applications transport and setu p. · 3,000- 7,000 SCFM of Airflow from Industrial-Grade Fans • Temporary on-site comfort heat for large • Painted Carbon Steel construction ensures capacity special events. weather resistance, with Stainless Steel • Multi-stage Contactor System available for extreme environments. for Accurate Temperature • Interim comfort heating system during Control commercial construction prior to permanent • Multi-stage, contactor-based control system HVAC installati on. for accurate temperature control. • NEMA 4 Electrical Enclosure for • Curing plaster and drying of paint in com­ Outdoor Weather Protection • High limit temperature control and low limit mercial construction. airflow control ensures proper safety during • Fork Lift Accessible • Spot heating for personnel and freeze pro­ operation. • Four-Point Lug Lifting System tection for equipment in the event of a plant • All electrical enclosures are easily accessible shutdown. and are protected to NEMA 4 construction. · Use with Standard 20" Flexible Duct Options • Chromalox HAGS systems are built to resis t the rough handling and transportation of the • Stackable to Maximize Storage • Special Voltage and Wattage requirements renta l market. Various control and fan op­ • Special Form Factor and Envelope tions allow for maximum flexibility to meet • Emergency Stop Button and the varying needs of rental companies and Fan Delay on Shutdown • SCR Power Control Pa nel their clients. · Optional SCR Power Control • 304 Stainless Steel Construction System for High Accuracy • Variable Speed Fan Motor • Camlok Power Connections • Voltmeter, Ammeter, and kW Meters • Phase Reversal Switch

Standard Models

C:hronnalox ® ------~•m·Eftml·• EDU Load Bank Energy Dissipation Units

• Portable, Forced Air Cooled Energy Dissipation Unit

• 100 - 1000 kW Resistive Capacity

• 240 or 480 V, 3-Phase, 60 Hz (600V Available)

Corrosion Resistant Stainless Description Options Steel Construction Ch romalox EDU Load Banks provide durable, • Special Voltage and Wattage Requirements • Heavy Duty 0.475" Dia. precise energy control fo r applications req uir­ INCOLOY® Sheath Tubular ing from 1 kW to megawatt power capacity. • Voltmeter, Ammeter, and kW Meters Elements Stainless steel construction and INCOLOY • Load Management Module for 5 MW tubular elements offer superior durability and • 1 kW or 10 kW Load Step performance even with heavy usage and in • Remote Control with 25 ft. Cord Resolution extreme environments. • 'Wrong Voltage Applied' Indicator NEMA 3R Electrical Enclosure Applicatious • Camlok Power Connections for Outdoor Protection Applications include factory or field testing • Phase Reversal Switch • Standard Digital Keypad and of diesel generators, braking resistors for • Fan Delay Switch Display for Load Switching inverter drives. base loading of remote or standby power plants, battery discharge test­ • CE Approved Models Available • Optional Voltage/Dual Voltage ing, and UPS testing. and Wattage

• Optional Multifunction Digital Advmztages Readout Meter (V, A, kW, Hz) • INCOLOY sheathed tubular heating elements provide long life under harsh envi ronments. • Optional Selector Switches or Push Buttons for Load • Stainless steel construction of a Chromalox Switching load bank ensures strength and corrosions· resistance. • Optional Load Management Module for Combined Loads up • A multi-stage, contactor-based control sys­ to5MW tem with 1 kW res olution ensu res accurate control. • High limit temperature control and low limit airflow control ensures proper safety. • All electrical enclosures are protected to NEMA 3R construction. • Chroma lox EDU Load Banks can be used to satisfy National Fi re Protection Association (NFPA) requirements for emergency and standby power systems.

Chronnalox ® ------~•1·1121' EDP Portable Load Bank Energy Dissipation Units

• Portable, Forced Air Cooled Energy Dissipation Unit

• 115 kW Resistive Capacity

• Dual Voltage Capability Rated for 100% @ 240/480 V, 3 Ph, 60 Hz 75% @ 208 V, 3 Ph, 60 Hz Description • An aluminum exterior ensures the corrosion­ The Chromalox EDP Portable Load Bank is resistant cha racteristics needed for rough • Lightweight Aluminum specially designed for flexibility and ease-of­ Construction environments while making the EDP as light use. Its compact, lightweight design packs a as possible. lot of power and options. • Compact Helical Open Coil • A Multi-stage, contactor-based control sys­ Elements Applications tem with 5 kW resolution ensures accurate control. • 5 kW Load Step Resolution The features of the EDP make it ideal for ap­ plications involving small AC power systems, • Dual voltage capability allows for 100% of • Toggle Switches for Load including factory testing of generators, UPS the rated load to be applied at both 240 V Switching systems, battery banks, and turbines. and 480 V. The EDP wi ll also operate with 75% of rated load at 208 V. Advantages • Standard Camlok Power • High limit temperature control ensure s im­ Connections • Compact Helical Open Coil heating elements mediate shutdown in case of overheating. provide a compact design that fits a maxi­ • Chromalox EDP Load Banks can be used to • Standard Multifunction Digital mum amount of power into th e smallest satisfy National Fire Protection Association Readout Meter (V, A, kW, Hz) possible space. (NFPA) requirements for emergency and • 480/240/208 Volt Selector Switch standby power systems. Standard Models • General Purpose Enclosure for Indoor Use

EDP-0115TG5 95

Note: Dimensions in inches. I~~t-- --- 29-1 /4 ------l)>~l riiiiiifl 22-1/2 • • • • • L~

C:hronnalox®------1•~·'~*11' Process Air Heaters Overview

• Fintube® Heaters

Finstrip* Heaters

Circular Finstri p® Heaters

• High Temperature Duct Heaters

• Medium Temperature Duct Heaters

Low Temperature Duct Heaters Fintubee Elements- The finned tubular de­ subdivided into 48 Amp maximum circuits in sign provides the same benefits as the finned compliance with the National Electrical Code. Heat processing applications vary widely strip heater and additional featu res, allowing The heater is provided with a Type "K" thermo­ from indu.stry to industry. Curing, drying, for special bending configurations to provide couple attached to the sheath of one element heat treating, comfort heating, sterilizing and higher concentrations of installed kW for a to be used with a Chromalox high limit control. bonding represent just a few of th e many uses given area. The elements can be supplied with bulkhead threaded fittings, and may include Medium Temperature- App lication tem ­ for electrically heated air. Applications vary in peratures to 750°F are common for ADH type temperature from super cool cryogenic to high optional hermetically sealed terminals, or extra heavy wall th ickness for use in atmospheres duct heaters which feature INCOLOY1> sheath temperatures up to 1200°F. Chromalox electric tubular heating elements. These versatile units heaters can also be designed to heat special containing hazardous fumes or gasses. Ele­ ment diameters of 0.315" and 0.475" are stan­ are fully assembled and prewired with the atmospheres such as argon or nitrogen. elements subdivided into 48 Amp maximum Special materials and custom designs are dard, with high temperature aluminum painted steel sheath and fu rnace brazed fins being the circuits in compliance with the National Elec­ available for marine applications, power plants trical Code. or hazardous applications. most common materials. Stainless Steel or MONELe sheath and fins are also available for Low Temperature -Outlet air temperatures Chromalox can supply individual finned ele­ corrosive environments. to 440°F are typical for types CAB, CABB and ments for use in OEM equipment or entire duct DAB which use finned strip heater elements heater assemblies where we have complete Duct Heater Assemblies in an assembly which is then inserted in and control over the product including the ele­ bolted to existing ductwork. ments, frames and controls. Chromalox has High Temperature -Type ADHT is designed earned an outstanding rep utation for excep­ to provide outlet air temperatures up to tional quality, reliability and long life. 1200°F using conservative ly rated, low watt density, INCOLOY3 tubular elements. The Filmed Hentiug Elements heater includes three inches of high tem­ perature rated insulation below the mounting Finstrip3 Elements- Superior to open flange to reduce heat transfer to the wiring coil elements, the heating coil is completely enclosure. The elements are prewired and encased in a metal sheath, minimizing a shock hazard due to accidental contact with the Process Ail· Heaters- Selectiou Guideliues heater. The rigid metal sheath minimizes hot spots and electrical shorting, likely with open coil elements. Application temperatures to Type I Feature I kW Rating I Model I Page 565°F are typical using finned strip units. Fintubee 0.475" Fintube• 0.47-10 FTS & FTI E-3 0.315" Fintube4'1 0.5 - 6.2 FTS & FTI E-4 0.475' Single End 0.5- 4.3 SFTS & SFTI E-5 0.315" Sinole End 0.3 - 2.4 SFTS & SFTI E-7 Finstrip• Finstripfl 0.2- 4.1 OTF E-9 Circular Stria 1.9- 5.0 KSEF E-11 Air Duct Medium Temperature 5 - 270 ADH E-14 High Temperature 5 - 300 ADHT E-15 Low Temperature 6 - 100 CAB &CABS E-17 Round Duct 2.5 -5 DAB E-19 Custom Air HeatinQ Solutions E-20

Chromalox®______,: recess 1r and Radiant

FTS &FTI c'i\lus .475" Dia. ~· Fintube®Heaters Dimensions (InciJes) Heated ~:--- 8----).j 0.475 , • Steel Sheath (type FTS) A A A A ~ A ~ A ~ A A A ~ - ~ \\\\ \V Y\ \\\\ ~ t ·, • MONEL~ Sheath (type FTI) I C l>-1 • 475- 10,000 Watts l+------A:t1% ------:l>-j

• 120, 240 and 480 Volt Featu1·es • 60 W/Jn2 Type 4 Terminals - Standard. Integral parts Bending-Customer's minimum bending • 750°F Max. Sheath Temp. of the element are of high strength to resist radius, see Factory and Customer Bending (type FTS) bending during tightening of the wiring con­ Table in the FT Series Overview. nections. Type 4 terminal is a threaded exten­ • 900°F Max. Sheath Temp. sion of the cold pin. See standard terminal Stainless Steel Sh eath -Optional. Contact your Local Chromalox Sales office. (type FTI) detail in the FT Series Overview. Work Temperatures-See Allowable Watt Special Features- Sheath material, threaded Density & Heater Selection Graphs G-151 fittings, length, volts, watts, brackets, etc. through G-156 in Technical section of this Contact your Local Chromalox Sales office for Applications catalog. price and availability. Best suited for the following applications where space is limited. Specification.s a11d Ordering bifomzation • Drying • Heat Treating • Annealing • Load Banks • Curing Ovens, Dryers, Ducts, etc.

Advantages

The metal sheath isolates and protects the resistor wire from the environment. At the same time it maximizes heat transfer capability to the work. Fintu be® elements can be bent to put the heat where it works best. Fi ns greatly increase surface area and permit faster heat transfer to the air, resulting in lower element surface temperatures. High watt density permits use of fewer elements and a higher concentration of installed kW for a given area.

Fin tube~ heaters are ideal for both comfort and industrial process air applications.

Chrornalox®------I'DIB'I SFTS & SFTI .4 7 5" Dia. Single End Fin tube®Heaters

• Steel Sheath (type SFTS)

• MONEL* Sheath (type SFTI)

• 500 - 4,350 Watts Applicatious

• 120, 240 and 480 Volt Best suited for the following applications High Watt Density permits use of fewer ele­ where space is limited. ments or higher concentration of installed kW • 60 Wfln2 for a given area. • Drying Lead Wires, 1o · long, with silicone-impreg­ • 750°F Max. Sheath Temp. • Heat Treating (type SFTS) nated Fiberglas:& sleeves. Maximum wire • Annealing temperature is 200°C. • 900°F Max. Sheath Temp. • Load Banks Leads are attached to terminals inside a (type SFTI) ceramic terminal bushing. • Curing Ovens, Dryers, Du cts, etc. Applicatio1l Tips Advantages Terminal Block should be on outside of duct Versatile- Ideal for both comfort and indus­ or heating area. trial process air applications. Element Supports should be provided for Single-End Terminals simplify wiring and every two feel of element length. eliminate the need for return wire. Work Temperatures- See Allowable Watt Install More Elements in Same Space as Density & Heater Selection Graphs G-151 standard, double-end Fintube1). through G-156 in Technical section. No Bending required to put all terminals in the Special Features- Sheath material, threaded same plane. fittings, length, volts, watts, brackets, etc. Contact your Local Chromalox Sales office for Smaller Heating Duct or Chamber in some price and availability. cases. Bending is not recomm end ed for single end Construction- Element is co nstructed like elements. Contact your Local Chromalox Sales the standard single-end tubular element with office . the addition of continuous spiral fins (4 - 5 per inch) permanently furnace brazed to the Stainless Steel Sheath- Optional. Contact sheath. your Local Chrom alox Sales office for price and availability. Fins greatly increase surface area and permit faster heat transfer to the air, resulting in lower element surface temperatures.

Chrornalox®------I'Dill'l SFTS & SFTI .315" Dia. Single End Fintube®Heaters

• Steel Sheath (type SFTS)

• MONEL® Sheath (type SFTI)

• 325 - 2,400 Watts ApplicatiotJS Fins greatly increase sur face area and permit faster heat transfer to the air, resulting in lower • 120 and 240 Volt Best suited for the following applications element surface temperatures. where space is limited. • 60 Wlln2 High Watt Density permits use of fewer ele­ • Drying ments or higher concentration of installed kW for a given area. • 750°F Max. Sheath Temp. • Heat Treating (type SFTS) Lead Wires, 10 ' long, with silicone-impreg­ • Annealing nated Fiberglas®sleeves. Maximum wire temperature is 200°C. • 900°F Max. Sheath Temp. • Load Banks (type SFTI) Le ads are attached to terminals inside a • Curing Ovens, Dryers, Ducts, etc. ceramic te rminal bushing.

Advmztages Applicatiou Tips Versatile- Ideal for both comfort and indus­ Terminal Block should be on outside of duct trial process air applications. or heating area. Single-End Terminals simplify wiring and Element Supports should be provided for eliminate the need for return wire. every two feet of element length. Install More Elements in Same Space as Work Temperatures- See Allowable Watt standard, double-end Fintubee. Density & Heater Selection Graphs G-151 No Bending required to put all terminals in the thro ugh G-1 56 in Technical section. same plane. Special Features- Sheath material, threaded Smaller Healing Duct or Chamber in some fittings, length, volts, watts, brackets, etc. cases. Contact your Local Chromalox Sales office for price and availability. Construction - Element is constructed like the standard single-end tubular el ement with Bending is not recommended for single end the addition of continuous spiral fins (4 - 5 elements. Contact your Local Chromalox Sales per inch) permanently furnace brazed to the office. sheath.

Chromalox®------OTF Finstrip®Air Heater

• Rust-Resisting Iron or Chrome Steel Sheath Dimeusious (Iucbes}

• 250 - 4,150 Watts

• 120 and 240 Volt

• Single Phase

• 225 - 565°F Max. Work Temp. A= Overall B = Mtg. Hole Centers • 1-1/2" Strip with Fins 2" Wide F = Finned

Specificatious and Orderiug lufomzatioll App/icatiom Dimensions (ln.) • Mount across Air Stream within Forced Air WI. (lbs.) Ducts Walls W/lnz Volts Model IStock PCN Rust-Resisting Iron Sheath - for Max. Sheath Temp. to 750•F • Use in Dryers, Ovens and other Process Air 250 11 120 10-1/2 9-1 /2 6-1/4 OTF-1 0 s 128004 2 Heating Equipment 350 15 120 10-1/2 9-1/2 6-1/4 OTF-10 s 128012 2 600 26 120 10-1/2 9-1/2 6-114 OTF-10 s 128020 2 • Comfort Heating in Ducts, Load Banks and 250 11 240 10-1/2 9-1/2 6-1/4 OTF-10 s 128039 2 350 15 240 10-112 9-1/2 6-1/4 OTF-10 s 128047 2 Humidity Controls 600 26 240 10-1/2 9-1/2 6-1/4 OTF-10 s 128055 2 ~ 500 18 120 12 11 7-3/4 OTF-12 s 128063 2 ff! • Many Air Blast and Convection requirements 750 27 120 12 11 7-3/4 OTF-12 s 128071 2 can be accommodated by the wide range of 250 9 240 12 11 7-3/4 OTF-1 2 s 128080 2 lengths, wattages and watt densities avail­ 500 18 240 12 11 7-3/4 OTF-12 s 128098 2 I able. 750 27 240 12 11 7-3/4 OTF-1 2 s 128100 2 900 24 120 14 13 9-3/4 OTF-1 4 s 128119 2 500 13 240 14 13 9-3/4 OTF-14 NS 128127 2 Applicatiou & Selectiou Guidelines 900 24 240 14 13 9-3/4 OTF-14 s 128135 2 325 8 120 15-1/4 14-1/4 11 OTF-15 s 128143 3 Maximum Work Temperatures- Finstrip® 1,000 25 120 15-1/4 14-1/4 11 OTF-15 s 128151 3 elements can generally be used in the ap­ 1 000 25 240 15-1/4 14-1/4 11 OTF-15 s 128160 3 500 10 120 17-7/8 16-7/8 13-5/8 OTF-18 s 128178 3 plications above, at maximum temperatures, 1,000 20 120 17-7/8 16-7/8 13-5/8 OTF-18 s 128186 3 without exceeding their capab ility, if properly 1,300 26 120 17-7/8 16-7/8 13-5/8 OTF-18 NS 128194 3 installed according to instructions packed with 500 10 240 17-7/8 16-7/8 13-5/8 OTF-18 s 128207 3 heater. 1,000 20 240 17-7/8 16-7/ 8 13-5/ 8 OTF-18 s 128215 3 1 300 26 240 17-7/8 16-7/8 13-5/8 OTF-1 8 s 128223 3 1,000 17 240 19-1/2 18-1/2 15-1/4 OTF-19 s 128240 3 Max. Outlet Air Temp . t•f) 1,500 26 120 19-1/2 18-1/2 15-1/4 OTF-19 s 128231 3 1 500 26 240 19-1/2 18-1/2 15-1/4 OTF-19 s 128258 3 Air Velocity Chrome 1,000 16 240 21 20 16-3/4 OTF-21 NS 128266 3 (Ft./Sec.) Iron Sheath Steel Sheath 1 550 26 240 21 20 16-3/4 OTF-21 NS 128274 3 Free A1r 750 10 240 23-3/4 22-3/4 19-1/2 OTF-24 s 128282 4 16 1,000 14 240 23-3/4 22-3/4 19-1/2 OTF-24 NS 128290 4 1 800 25 240 23-3/4 22-3/4 19-1/2 OTF-24 s 128303 4 1,250 16 240 25-1/2 24-1/2 21-1/ 4 OTF-25 NS 128602 4 Note- Maximum temperatures are based on 2 000 26 240 25-1/2 24-1/2 21-1/4 OTF-25 s 128610 4 15 W/ln2 density for iron sheath and 20 W/ln2 700 8 120 26-3/4 25-3/4 22-1/2 OTF-26 NS 128629 4 700 8 240 26-3/4 25-3/4 22-1/2 OTF-26 NS 128637 4 density for chrome steel sheath. If elements 1,350 16 240 26-3/4 25-3/4 22-1/2 OTF-26 s 128645 4 have a lower watt density, work temperature 2 000 24 240 26-3/4 25-3/4 22-112 OTF-26 NS 128653 4 may be increased; if watt density is higher, 1,500 16 240 30-1/2 29-3/8 25-1/4 OTF-30 s 128952 4 work temperature should be lower. 2 350 25 240 30-1/2 29-3/8 25-1/4 OTF-30 s 128670 4 1,000 9 240 35-7/8 34-7/8 30-5/8 OTF-36 s 128688 5 1,800 16 240 35-7/8 34-7/8 30-5/8 OTF-36 NS 128696 5 See Allowable Watt Density & Finstrip~ Heater 2 850 26 240 35-7/8 34-7/8 30-5/8 OTF-36 NS 128709 5 Selection Graphs G-1 07S and G-1 08S in the 2,000 16 240 38-1/2 37-5/8 33-1/4 OTF-38 s 128960 5 Technical section of th is catalog. 3,100 25 120 38-1/2 37-5/8 33-1/4 OTF-38 NS 128717 5 3100 25 240 38-1/2 37-5/8 33-1/4 OTF-38 s 128725 5 3 450 26 240 42-1/2 41-3/8 37-1/4 OTF-43 s 128733 6 Chromalox®------KSEF Preformed Circular Finstrip® Diuwzsio1zs (lncl~es) Air Duct Heater

• Rust-Resisting Iron or MONELe Sheath and Fins

• 1 ,950 - 5,000 Watts

• 120 and 240 Volt Applications Note - Maximum temperatures are based • Single Phase on 25 W/ln2• If elements have a lowe r watt • Heat moving Air or Gas in Round Ducts density, wo rk temperature may be increased; if watt density is higher, work temperatu re • Booster Heater in Process and Comfort should be lower. Heatin g Du cts Note - See Allowable Watt Density & Heater • Convert existing Forced Air Dryers and Selection Graphs G-107 S and G-108 S in the Ovens Technical section of this cata log. Applicatiou & Selectiou Guidelines Featm·es Maximum Work Temperatures- Finstripe elements can generally be used in the follow­ Durability is assured by rugged Chromalox ing applications at maximum temperatures, strip heater with locked -on fins. with out exceeding their capability, if properly Rapid Heat Transfer to air fro m larg e finned installed according to instructions packed with heaters. area. Nested Elements- Elements may be nested. AirVelocity ~ Open Con stru ction -Requires mounting (Ft./Sec.) [ !flln!IJea_tll_ !1\'l_O~L ~_!Illl~ 4 brackets to be fa bricated by user. 9 16

Specijicatio1zs a11d Orderi11g bifonnation

Stock Status: S = stock NS = non-stock To Order- Specify model, PCN, watts, volts and quantity.

Note - Chromalox can supply other sizes and ratings. Contact your Local Chromalox Sales office.

C:hronnalox ® ------~'11';''1 ADH &ADHT Series High Temperature Air Duct Heaters (cont'd.) ADHT- Dimemiom (Inches} (See Dimemiotzal Table) Ill~ II ADH- Dimmsio1ts (luches} (See Dimeusional Table}

Ill ..,

l .._ i _ ,..ll /~-- ~ H""" ~ Airllow \~ "'- Direclion IV X Hole- ~ Duel opening D Hole- Duel opening Is ~ D + 1/4 by M + 1/4 is D + 1/4 ""- byM+1/4 ~ Dimmsio11al Table ADH I ADHT

All Healers can be mounted in any position; lop, side or bottom entry. In high ambient temperature operations, least corrosrve action and least oxidation to the terminals wrll occur if heaters are mounted with terminals in the coolest possible ambient, usually on bottom or side of duct. Mlmumum duel size is A or L dimension plus 3/8' and 6 dimension plus 1·5/8', and 3' for msulatron housing. Electrical Table for ADH and ADHT Duct heaters For selecting the proper control panel for use with . ~~ro I Circuits the ADH and ADHT duct heaters, the number of cir­ cuits is of crucial importance. The Electrical tabl e, at 1 right, should be used for the purpose of determining the number of circuits in the panel. 1 1 Field Wiring- Refer to Graph ADHTB Terminal 1 Box Temperature field wiring selection guide in the ~ 1 technical section of this catalog (Section 1).

Gas tight construction should be considered if the gas pressure in the duct is at a higher relative pres­ sure than in the terminal box which is at room air pressure. Refer to ADH/ADHT terminal box tempera­ ture and field wiring selection guide showing the temperatu re in the terminal box at various gas outlet 4 temperatures. This guide is graph ADHTB located 4 in the Air and Gas Heating sec tion in th e technical 4; pages in the back of the catalog.

All slaMard crrcu11s are maxrmum ol 48 Amps For other I of circuoiS/amps per corcuol consulrtacrory 0 X denotes not standard Chromalox®------~'l'lf•' ADHT Application & Selectio11 Guidelines Air Velocity High Temperature Maximum Work Temperatures- Type ADHT heat­ (Fl./Sec.) I Max. Outlet Air Temp . (°F) ers can generally be used at the following maximum 4 1050 Air Duct Heater temperatures, provided the minimum air velocity is 9 1100 maintained uniformly through the heater. Maximum 16 1150 25 1200 temperatures are based on 20 W/ln2• 36 1200 • 5-300 kW Note -See Allowable Watt Density & Heater Selec­ tion Graphs in Technical section. • 240 and 480 Volt, Three Phase Note - An airflow type switch or other device is (Up to 600V Available) recommended to protect against loss of airflow. • INCOLQY® Sheath Elements

• 20 W/ln2

• 1200°F Max. Outlet Air Temp.

• Insulated Standoff Collar

TypeADHT Coustruction Rugged Construction Elemen ts - Sturdy 0.475' diameter INCOLOY~ sheath tubular elements are mounted to a heavy 1/4 or 3/8' thick steel flange. Element fasteners to allow for easy replacement. Corrosion-Resistant Terminal Enclosure- The element terminal enclosure is made of 16 gauge high-temperature, corrosion-resistant steel and includes 1' th ick high-temperature insulation to minimize temperatures in th e wiring area. Wiring Box- The 16 gauge wiring box encloses individual terminal blocks for each circuit. Threaded stud type terminals are provided to permit quick positive attachment of circuit wiring conductors. Insulation Housing -Includes 3' of high tem­ perature thermal insulation to reduce duct heat conducted into terminal enclosure. Overtemperature Protection -A type K thermo­ couple is welded to the element sheath surface to sense element temperature, and is wired to a terminal block located on the outer surface of the terminal housing. Momzting Generally mounted to a field fabricated stand off collar from the ductwork to position the heater such that the 3' insulation housing is in the same plane as the duct insulation. All Heaters can be mounted in any position; top, side or bottom entry. In high ambient temperature operations, least corrosive action and least oxidation to the te rminals will occur if heaters are mounted with terminals in the coolest possible ambient, usu­ ally on bottom or side of duct. Minimum duct size is A or L dimension plus 3/8' and B dimension plus 1·5/8', and 3' for insulation housing.

Chromalox®------~'lllfEI' rocess Air and Radiant

Terminal CAB &CABB Cover Low Temperature 4·3/16 Air Duct Heaters

• Side Terminals (type CAB) 10 • Bottom Terminals (type CABB) 3/4, 1, 1-1/4, 1-1/2. 1.., 2, 2-1/2 Combinallon I K.O. (each end) • 6- 100 kW Dimensious (Iucbes) Overtempemhtre Protectioll • 120, 208, 240 and 480 Volt

• 1 or 3 Phase

• Rust-Resisting Iron or Chrome Steel Sheath Elements

• 440°F Max. Outlet Air Temp.

Applicatiom • Sole Heat Source • Booster Heater in Process and Comfort Heating Ducts • Convert existing Forced Air Dryers and Ovens Comh·uctioll Applicatio11 & Selecti01z Guideli11es • With Blower and Duct, can be used to Fabricate simple Forced Air Drying Unit Rugged Finstrip• Elements are mounted in Selection Heater Size - Refer to Tech ni - a sturdy steel frame with narrow side of ele­ cal section for examples on determining kW Feahtres ments and fins facing the air flow. requirements. For quick estimating purposes, the following formula may be used for air at Simple Duct Tra nsition Sections may be used Finstrip• Elements, Exclusive Construc­ standard conditions: to adapt standard heater sizes to various duct tion- High-quality, coiled resistor wire is sizes to increase air velocities for better heat uniformly spaced over the width and length kW = SCFM x Temp. Rise (°F) transfer, lower sheath temperature and longer of the Fins trip• element, then embedded in 3000 high-grade refractory material which insulates element life. Maximum Work Temperatures- Type CAB the wire and transfers heat rapidly. Refrac­ and CABB heaters can generally be used at th e Field Wiring Terminals- Heavy duty 3/8. tory is then compressed to rock hard ne ss and following maximum temperatures, provided diameter bolts of either brass (iron sheath maximum density under tremendou s hydraulic the minimum air velocity is maintained uni­ units) or Stainless Steel (chrome steel sheath pressure to improve heat transfer from coil units) with necessary hardware are provided to sheath. Elements are oven baked at high formly through the heater. for field wiring connections. Terminals are temperatures to semi-vitrify and mature the located on the side for CAB units and on the refractory. Sheath material is either rust-resist­ Ai r Max. Outlet Air Tern . •f bottom for CABB units, and should be on the ing iron or chrome steel. Ve locity Iron Ch rome Steel outside of dueling. (Ft./Sec.) Sheath Sheath Sturdy Steel Frame -14 gauge cold rolled 4 200 Fins of aluminized steel are provided to im­ steel painted with high heat resisting black 9 90 330 prove heat transfer to the air. enamel paint. 16 220 440 Elements are individually replaceable. Internal Electrical Connections are made using a combination of buss bars and jumper Note- Maximum temperatures are based Terminal Cover Option is available to prevent straps consisting of either Manganese-Nickel on 26 W/ln2• If elements have a lower watt accidental contact with live electrical terminals density, work temperatures may be increased; (PCN 269720), one (1) requ ired per circuit. or MONEL®. if watt density is higher, work temperatures MONELe Sheath and MONEL* Fins are avail­ Mormti11g should be lower. able for humid co nditions. Model TDH heaters, using Fintubee elements are also available. Always install heaters in duct work with Note - See Allowable Watt Density & Heater Contact your Local Chromalox terminal box on bottom of heater. Type CAB Selection Graphs and Pressure Drop Curve Sales office. units should have field wiring terminals facing G-112S1 under Air & Gas Heating Data in the upstream to provide maximum cooling affect. Tec hnical section of this catalog. Secure to duct work using mounti ng holes on both vertical sides of heater. C:hronnalox ® ------~'11'1''1 DAB Round Low Temperature Dimetzsi07ts (Inches) Air Duct Heater

• 2.5-5 kW

• 240 Volt

• Single Phase

• Rust-Resisting Iron or MONEL

Rug ged KSEF Koilfine El ements UL Maximum Work Temperatures- Finstrip8 el­ ements can generally be used at the following Applications Recogn ized and CSA Certified, are enclosed in a spun steel round frame. maximum temperatures, without exceeding their capability, if properly installed according • Use in Dryers, Ovens and other Process Air Element - Rust-Resisting Iron or MONELe to instructions packed with heaters. Heating Equipment sheath. • Comfort Heating in Ducts, Load Banks and Mounting Gasket -Furnished with each Humidity Controls heater to minimize air leakage between the AirVelocity ~ heate r and the mounting surface or be tween (Ft./Sec.) ~· • Sole Heat Source heaters. 4 250 I 9 I 150 I 370 • Booster Heater in Process and Comfort BaHie- Steel baffle furnished to close the l 16 I 250 I 450 Heating Ducts center opening. When a multiple of units are inte rconnected, only the first and last heater Note - Maximum work temperatures are are closed. based on 25 W/ln2. If elements have a lower Features watt density, work temperature may be in­ creased; if watt density is higher, work Easy Installation in Round Ducts- Flange temperature should be lower. permits easy ganging of units to augment Note - See Allowable Watt Density & Heater heating capacity. Selection Graphs in Technical section. Air is Forced Over Elements Only- The center opening of all DAB units may be closed with a sheet steel baffle furn ished with the unit.

Specificatiotts a11d Orderi11g biformation Dimensions (ln.) WI. Watts Volts W/ln2 Model Stock PCN (lbs.) Rust-Resisting Iron Sheath - for Max. Sheath Temp. to 7SO•F 2,500 240 27 12-3/16 6-9/16 DAB-30 NS 264014 6 3,000 240 27 13-15/16 8-5/ 16 DAB-36 NS 264030 10 4,000 240 25 17-1 1/16 12-1/ 16 DAB-48 NS 264057 14 5 000 240 27 19-11/16 14-1/16 DAB-54 NS 264073 16 MONEL• Sheath - for Max. Sheath Temp. to soo•F 2,500 240 27 12-3/ 16 6-9/16 DAB-30M s 264022 6 3,000 240 27 13-15/16 8-5/16 DAB-36M NS 264049 10 4,000 240 25 17-11/ 16 12-1/16 DAB-48M NS 264065 14 5 000 240 27 19-11/16 14-1/ 16 DAB-54M NS 264081 16 II"' Stock Status: S =stock NS = non-stock To Order-Specify model. PCN, watts, volts and quantity.

Note - Chroma lox can supply other sizes and ratings. Contact your Local Chromalox S ales office.

C:hronnatox®------1'11'1ijll