Sight Glass Level Gauges Data Sheet Sight Glass Level Gauges

Total Page:16

File Type:pdf, Size:1020Kb

Sight Glass Level Gauges Data Sheet Sight Glass Level Gauges Level Measurement Sight Glass Level Gauges Data Sheet Sight Glass Level Gauges Description Accessories Level Gauges for direct reading of Iiquid levels in vessels and ■ Drain and vent tanks. ■ Illumination ■ Heating Applications ■ Scale ■ Refineries ■ Frost protection ■ Off-shore ■ Ultraviolet protection ■ Oil and gas ■ Corrosion protection ■ Power stations ■ Lining/coating PTFE/Halar, rubber ■ Chemical plants ■ Thermofluid oil installations Certificates ■ Refrigerating plants ■ Test certificates according to DIN EN 10204 ■ Cyrogenic services ■ Sour gas regulation NACE ■ Tests to customers requirements Rating ■ Pressure rating PN 6 – 250 Neccessary data ■ Operating temperatures from – 200 up to + 400 °C Glass type, Design pressure (p), Design temperature (T), center to center distance (ME), visible length (SL), materials, Product groups process connection, ex classification, quantity ■ Reflex type ■ Transparent type with glass or mica Special constructions available upon request. ■ Refraction type For further details please use our datasheets. ■ Tubular type Chambers ■ fixed, flanged, pivoted, screwed or weldable ■ interrupted or continuous visible length Materials ■ Forged steel, stainless steel, suitable for pressure equipment according to EN or ASME ■ Particularly corrosion resistant materials as Duplex, Monel, Inconel, Hastelloy, Titanium, etc. Shut-off valves ■ handwheel or quick closing lever ■ with ball check ■ flanged or union connection Data Sheet Sight Glass Level Gauges ∙ 06/2013 Page 1 of 54 Sight Glass Level Gauges Type Overview Basic- Pressure Gauge Internal Body type Connection Actuation Special Page Type rating valve connection 700.12 CL 300 reflex, transparent side-side fixed 760.51..52 nipple handwheel 8 700.12A CL 900 reflex, transparent side-side fixed 760.51..52 nipplel handwheel 9 700.13 CL 300 reflex, transparent side-side fixed 760.56..57 nipple Schnellschluss offset 10 700.13A CL 600 reflex, transparent side-side fixed 760.56..57 nipple Schnellschluss offset 11 700.21 CL 300 reflex, transparent top-bottom pivoted 760.53 nipple handwheel offset 12 700.21A CL 900 reflex, transparent top-bottom pivoted 760.53 nipple handwheel offset 13 700.23 CL 300 reflex, transparent top-bottom pivoted 760.58 nipple Schnellschluss offset 14 700.23A CL 600 reflex, transparent top-bottom pivoted 760.58 nipple Schnellschluss offset 15 700.26 CL 1500 reflex, transparent side-side fixed 760.51..52 nipple handwheel 16 700.27 CL 1500 reflex, transparent top-bottom pivoted 760.53 nipple handwheel offset 17 reflex, transparent 700.46 CL 300 top-bottom without/with 18 large chamber reflex, transparent 700.31 CL 300 without 19 open back, bridge-weld pad reflex, side plates 700.B1 CL 300 side-side fixed integrated rigid handwheel 20 hingedr 700.B3 PN 40 reflex top-bottom integrated rigid handwheel 21 reflex, side plates 700.B5 PN 40 top-bottom 760.11 nipple lever 23 hinged reflex, pressure frame 700.B7 PN 40 backside 760.11 nipple lever 24 15° diagonally 700.C0 PN 40 transparent backside integrated rigid handwheel 25 700.C4 PN 63 transparent backside integrated rigid handwheel 26 700.C5 PN 100 transparent backside 760.68 union lever 27 up to CL handwheel + 700.C6 reflex, transparent side-side fixed 760.18 flanged double shut-off 28 600 lever 700.C7 PN 100 red-green backside 760.68 nipple handwheel 29 handwheel + 700.C8 PN 160 refraction, mica backside 760.18 nipple double shut-off 30 lever handwheel + 700.CA CL 1500 refraction, mica backside 760.19 nipple double shut-off 31 lever glass tube 13,5 mm, 700.A1 PN 10 top-bottom pivoted screwed handwheeld 32 steel, glass protection glass tube 13,5 mm, 700.A2 PN 10 top-bottom pivoted screwed handwheel 33 Ms, glass protection glass tube 13,5 mm, 700.A3 PN 10 top-bottom pivoted screwed handwheel 34 SS, glass protection glass tube 13,5 mm, 700.A4 PN 10 top-bottom pivoted without screwed 35 SS, glass protection glass tube 16 mm, 700.01 CL 150 top-bottom pivoted 760.01 screwed handwheel offset 36 glass protection, ZGH*) glass tube 16 mm, 700.03 CL 150 top-bottom pivoted 760.03 screwed lever offset 37 glass protection, ZGH*) *) GH = Glass holder in-between Page 2 of 54 Data Sheet Sight Glass Level Gauges ∙ 06/2013 Valves Type Overview Pressure Type Actuation Connection body Thruway Pattern Stem thread Page rating 760.51 CL 1500 handwheel nipple straight inline inside 38 760.52 CL 1500 handwheel nipple angle inline inside 39 760.53 CL 1500 handwheel nipple angle offset inside 40 760.56 CL 600 quick closing valve nipple straight inline inside 41 760.57 CL 600 quick closing valve nipple Eck inline inside 42 760.58 CL 600 quick closing valve nipple angle offset inside 43 760.01 CL 1500 handwheel nipple angle offset inside 44 760.03 CL 600 quick closing valve nipple angle offset inside 45 760.11 CL 300 quick closing valve nipple angle inline inside 46 760.18 CL 900 handwheel / lever nipple angle inline inside 47 760.19 CL 1500 handwheel / lever nipple angle inline inside 48 760.68 CL 600 quick closing valve nipple straight inline inside 49 Sight Glass Level Gauges Accessories Type Description Page 709.0XXX Illumination Transparent Sight Glass Level Gauges 50 Sight Glass Level Gauges Connections 51 Frost protection / Flat glasses / Gaskets 52 Mica and gasket / Mica packages PDESIGN / Corrosion protection / Pointer low water 53 Corrosion protection with mica / Corrosion protection and anti-adhesive / Scale / Heating 54 Data Sheet Sight Glass Level Gauges ∙ 06/2013 Page 3 of 54 Functional Description Sight Glass Level Gauges Reflex glass type acc. to DIN 7081 Incident light is reflected at the reflex grooves of the sight glass plate covered by gas and is broken into the liquid in the part covered by medium. The liquid level is visible as a dark bar, the gaseous space as a silvery bar. Sight direction Sight direction Gaseous phase Liquid phase Transparent glass type acc. to DIN 7081 Incident light is reflected at the reflex grooves of the sight glass plate covered by gas and is broken into the liquid in the part covered by medium. The liquid level is visible as a dark bar, the gaseous space as a silvery bar. Sight direction acc. to DIN 7081 Refraction type with mica sheets The incident light of a lamp is guided through the two mica sheet packages in an angle and passes the medium between them. In gaseous phase the light is guided straight forward and passes both mica packets, in liquid the light is refracted away. The liquid level is visible as a black bar and the gas as a bright bar. Sight direction Refraction type with mica sheets Page 4 of 54 Data Sheet Sight Glass Level Gauges ∙ 06/2013 Design Sight Glass Level Gauges The main part of the sight glass level gauge is the chamber. cases up to 400 °C. Borosilicate glass is standard quality. For A duct for the medium (or heating agent) is machined into the conditions above the natural mineral mica is used. The process gauge body as well as the support surfaces for the gaskets connection normally is equipped with gauge valves. Drain valves and glasses or micas. Glass plates and/or micas are mounted are used for draining the gauge and are generally mounted on with gasket and cushion and are fixed with the cover plate or the lower end of the gauge body. In Special cases a vent valve pressure frames and bolts. The glass plates used for sight can be installed on the upper end. glass level gauges correspond to DIN 7081 and are suitable for temperatures up to 243 °C (280 °C when protected with mica) for steam, up to 300 °C for other Iiquids, and in special Gauge body Glass Contains the liquid duct, the level corresponds with the level Glass plates according to DIN 7081, made of Borosilicate- in the vessel. Glass, quartz, Aluminum silicate Cover Cushion Clamping for Glass plate. Mechanical protection between cover and glass Gasket Bolt / Nut Recessed sealing between liquid duct and ambient Take up the forces of the pressure inside. Gauge body Cover Bolt Gasket Glass Nut Cushion Data Sheet Sight Glass Level Gauges ∙ 06/2013 Page 5 of 54 Gauge valves Functional description The gauge valves are used to shut off the the vessel against or a handwheel. All gauge valves are equipped with a ball the level gauge. The actuation can be done by a lever (120°) check as a safety device.. Functional principle ball check ball check at leakage situation during putting situation in normal into operation operation The ball check is a safety device which is used in all gauge causing flow of liquid, the ball is driven to the seat by the valves. It’s task is to avoid heavy leakage after breaking of a liquid (L1p > 0,5 bar). This closes the valve and stops heavy glass or mica window or leakages due to other reasons. The leakage. ball is located below the seat. As soon as there is leakage Operation directions of quick closing valve and handwheel valve valve open open 120° 120° 120° C O O C 120° O C C O O C O C O C quick closing valve (QC) valve valve closed closed actuation direction actuation direction handwheel (HW) left (LI) right (RE) closing direction always right View direction onto vessel left (LI) front (VO) right (RE) Complete specification for view direction and valve orientation Sight direction actuation direction valve actuator valve type e. g. view direction left, actuation direction right, quick closing, angle type: LI-RE-SS-Eck Page 6 of 54 Data Sheet Sight Glass Level Gauges ∙ 06/2013 Arrangement of Sections Flat glasses acc. to DIN 7081 L SL A>=45 backside view glass type 2 standard normal indication interrupted uninterrupted indication with bypass Visible length
Recommended publications
  • Steamboating Guide Edition 2 2010
    Steamboating SampleGuide Pages Second Edition Steamboating Guide Edition 2 2010 Edited by Roger Calvert and Rob van Es The contributors and editors of this publication have made every effort to ensure the accuracy and relevance of the data presented and the validity and appropriateness of the recommendations made. It is, however, ultimately the responsibility of the owner of a boat to check the data and take the final decisions, in the context of the proposed design. If necessary, appropriate professional advice should be sought. Neither the contributors, the editors, nor the SBA can accept responsibility for any direct or indirect consequences arising from the use of the data or from following the recommendationsSample of this publication. Pages Copying of parts or the whole of this document by members of the SBA is permitted, subject to the terms published on the SBA web site. Otherwise, copying is not permitted without the permission of the SBA, except as allowed under copyright law. Table of Contents Preface Section A – Introduction 1 Hulls 1-1 2 Boiler Types 2-1 3 Engine Types 3-1 4 Fuels 4-1 Section B – Steamboat Operations 5 Boiler Fittings 5-1 6 Steam Plant Installation 6-1 7 Boiler Operation and Maintenance 7-1 8 Steam Ancillaries 8-1 9 Boat Handling Advice 9-1 10 Boiler Inspection and Testing 10-1 11 Trailers and Towing 11-1 Section C – Technical 12 Propulsion 12-1 13 Valve Setting 13-1 14 Data and Performance 14-1 15 Boiler Design Considerations 15-1 16 Workshop Techniques 16-1 Glossary 17-1 Index 18-1 Sample Pages Preface The aims and objects of the Steam Boat Association are: (i) To foster and encourage steam boating and the building, development, preservation and restoration of steam boats and steam machinery, by all possible means.
    [Show full text]
  • Instruction Manual GS-4 Daylight Live Steam Alcohol Fired
    Instruction Manual GS-4 Daylight Live Steam Alcohol Fired Southern Pacific GS-4 4-8-4 No. 4449 ACCUCRAFT COMPANY 33268 Central Avenue Union City, CA 94587 ACCUCRAFT Tel: 510 324-3399 T R A I N S Fax: 510 324-3366 email:[email protected] Copyright 2005 GS-4 Daylight Live Steam – Alcohol Fired GS-4 Daylight Live Steam – Alcohol Fired Prototype Information: NOTES: Californians who witnessed the early runs of the Southern Pacific red, orange and black consists declared them to be “the most beautiful trains in the world”. The striping on locomotive, tender, and the length of the train presented a bright, cheery image to a nation emerging from the Great Depression. In 1941, Lima built 28 GS4-class 4-8-4s, and were numbered from 4430 -- 4457. No. 4449 was the only Daylight painted GS-class preserved after lying stationary for years in a park in Portland, Oregon, she was resurrected in red, white and blue livery in 1975 to pull the American Freedom Train around the U.S.A to commemorate the Bicentennial of American Independence. Since then, the 4449 has been meticulously maintained. Today, the 4449 is occasionally run on special trips. 1 10 GS-4 Daylight Live Steam – Alcohol Fired GS-4 Daylight Live Steam – Alcohol Fired General information About 4. Place taped locomotive on Accucraft GS-4 Daylight Model: a level flat surface. Carefully cut the tape along the wood board side Operating a model live-steam 3. Always make sure the fire is surface. Be sure to cut both sides locomotive is much different from out before refueling the locomotive.
    [Show full text]
  • 1 11/19 DIVISION FIFTEEN MECHANICAL Section 15010
    DIVISION FIFTEEN MECHANICAL Section 15010 General Provisions Section 15050 Basic Materials and Methods Section 15250 Insulation Section 15350 Natural Gas Piping Section 15351 Compressed Air Piping System Section 15401 Domestic Water Piping System Section 15405 Soil, Waste, and Vent System Section 15406 Roof Drainage System Section 15420 Plumbing Equipment Section 15422 Domestic Recirculating Pump-ECM Section 15423 Domestic Recirculating Pump Section 15424 Domestic Electric Water Heaters Section 15425 Domestic Gas Water Heaters Section 15426 Condensing Domestic Gas Water Heater Section 15432 Domestic Water Pressure Booster System Section 15436 Small Rainwater Harvesting System (above ground) Section 15450 Plumbing Fixtures and Trim - Elementary Schools Section 15451 Plumbing Fixtures and Trim - Intermediate & High Schools Section 15500 Automatic Sprinkler System Section 15540 Fire Pump Assembly Section 15601 Atmospheric Modular Boilers Section 15604 Fuel Oil Piping & Accessories Section 15605 Fuel Oil Transfer Pumps Section 15607 Underground Storage Tank and Accessories Section 15608 Underground Storage Tank Removal Section 15616 Boiler and Water Heater Vent Section 15620 High Efficiency Boilers Section 15622 Cast Iron Boilers & Burners Section 15624 Steel Boilers and Burners Section 15625 Boiler Burner Replacement and Boiler Conversion Section 15651 Refrigeration Piping Systems Section 15655 Combination Split System Air Handler/Remote Air Cooled Condensing Units Section 15674 Water Cooled Chiller Section 15676 Air Cooled Chiller Section
    [Show full text]
  • 41-298 Optimizing the Steam Generation Cycle and Condensate
    Optimizing the Steam Generation Cycle and Condensate Recovery Process for Profit Donald Hite, Business Development Manager Magnetrol® International and Orion Instruments® Objective To identify key areas in the steam generation cycle and condensate As a consequence, the performance of any level technology relative to and waste heat recovery systems where cost-effective instrumentation instrument induced errors, calibration nuances, and vulnerabilities to solutions offer a tangible return on investment over the short term. process dynamics can have an immediate and adverse impact on fuel The goal is to reduce heat rate, environmental impact, fuel and water consumption while contributing negatively in other aspects of the process consumption, water treatment and maintenance costs in commercial be it makeup water requirements, excessive boiler blowdown, energy and heavy industries where steam generation is essential to the transfer, etc. Unfortunately, these other aspects of the process indirectly production processes. contribute to the inefficient use of fuel and hinder production throughput and product quality. Adding to this burden is the potential for damage Overview to expensive hardware resulting in forced outages, unscheduled, costly • Why control? maintenance, and production downtime. • Steam generation Boiler/steam drum “The U.S. pulp and paper industry—defined as Deaeration facilities engaged in the manufacture of pulp, paper, Blowdown and paperboard—consumes over $7 billion worth • Condensate and waste heat recovery of purchased fuels and electricity per year. Energy Cost benefits of condensate recovery efficiency improvement is an important way to reduce Condensate receiver tanks these costs and to increase predictable earnings, Pump protection especially in times of high energy price volatility.” Flash tanks and heat exchangers/condensers Berkeley National Laboratory • Water chemistry and treatment Environmental Energy Technologies Division, October 2009.
    [Show full text]
  • Guidance on Safe Operation of Steam Boilers
    Guidance on Safe Operation of Steam Boilers Ref: BG01 A joint document by the Safety Assessment Federation and The Combustion Engineering Association produced originally in consultation with the Health & Safety Executive. Guidance on the Safe Operation of Steam Boilers (Ref: BG01) A joint document by The Combustion Engineering Association and the Safety Assessment Federation originally produced in consultation with the Health & Safety Executive. Edition 2 – March 2019 © All rights reserved BG01 Guidance on the safe Operation of Steam Boilers Edition 2 – © 2019 Page 1 Guidance on the Safe Operation of Steam Boilers (Ref: BG01) Foreword This document, Guidance on the Safe Operation of Steam Boilers (BG01) has been developed and written by the Combustion Engineering Association (CEA) and the Safety Assessment Federation (SAFed) in consultation with other stakeholders within the boiler industry to help designers, managers and operators of new and existing boiler systems make health and safety and environmental improvements in the industry. This revision (Edition 2) incorporates up-to-date information and best practices relating to the operation of steam boiler plant; hot water boilers will now be covered in a separate document. This publication should not be regarded as an authoritative interpretation of the law, nor a mandatory legal requirement. However, if the guidance provided is followed, it will normally be regarded as sufficient to comply with the relevant health and safety duties. Cover image courtesy of Vital Energi. Acknowledgements SAFed and CEA acknowledge the support of the Health and Safety Executive in producing the original guidance, this second edition recognises changes in legislation and guidance since the first edition and incorporates comments and suggestions from users arising from widespread use of this guidance document in industry.
    [Show full text]
  • Power Generation Application Guide Contents Fossil Fuel - Coal Fired Boiler
    Power Generation Application Guide Contents Fossil Fuel - Coal Fired Boiler Ball Valves Outperform Competition 3 V1 Series Features & Benefits 4 Fossil Fuel Plant Basics 5 High Pressure Feedwater 7 Boiler System 11 Electronic Relief Valve (ERV) 14 Sootblower System 15 Inerting Steam 17 Turbine Steam & Extraction System 18 Combined Cycle Combined Cycle Plant Basics 21 HRSG Detail 22 Applications 23 Proper Directional Installation 27 Conversion Tables 29 ValvTechnologies Power Product Line 30 Power Generation Application Guide 1 ©2009 ValvTechnologies, Inc. Built for the job. ValvTechnologies designs and manufactures valves specifically for the unique demands of power generation applications. Zero Leakage = The standard operating conditions of power generation: high temperatures, high pressures True Cost Savings and at times, high cycling, can severely impact the service life of a valve. Special consideration should be made in the selection of metallurgy, sealing design and operation. Long Term Reliability ValvTechnologies, a leading global manufacturer of metal-seated, severe service valves, has Reduce Valve Maintenance a proven performance record of providing field tested,ZERO LEAKAGE solutions. Improve Heat Rate Our approach at ValvTechnologies is to utilize our technology, product management, Saves Energy, Time and Money inventory control, asset management, and world-wide service and support, to help solve process problems in your plant. By equipping the most knowledgeable people with the latest technology, we have created solutions where quality and dependability are built into our products and services from start to finish. By focusing on this principle, we become an integral part of our customer’s asset management strategy. ValvTechnologies’ valves meet the standards of: ASME codes B31.1 Power Piping Code ASME Section 1 Boiler and Pressure Vessel Code B16.34 Valve Standards ASME TDP-1 1998 Prevention of Water Damage to Steam Turbines, Part 1 ValvTechnologies metal-seated valves are designed to meet virtually any process condition.
    [Show full text]
  • Attachment 4: Planned Activities and Preventative
    Facility Procedures Manual JCC Planned Activities and Preventative Maintenance Standards Facility Procedures Manual Table of Contents Table of Contents . 3 Accessibility Systems A1 Access Doors, Gates and Sally Ports Monthly PM Procedures . 7 A1 Access Doors, Gates and Sally Ports Annual PM Procedures . 9 HVAC Systems H1 Air Cooled DX (Split System) Quarterly PM Procedures . 11 H1 Air Cooled DX (Split System) Annual PM Procedures . 19 H2 Air Handling Unit (Air Cooled DX/Package) Quarterly PM Procedures . 27 H2 Air Handling Unit (Air Cooled DX/Package) Annual PM Procedures . 35 H3 Air-Cooled Chiller Monthly PM Procedures . 45 H3 Air-Cooled Chiller Annual PM Procedures . 51 H4 Centrifugal Chiller Monthly PM Procedures . 59 H4 Centrifugal Chiller Annual PM Procedures . 65 H5 Cooling Tower (Induced Draft) Monthly PM Procedure . 73 H5 Cooling Tower (Induced Draft) Quarterly PM Procedure . 79 H5 Cooling Tower (Induced Draft) Annual PM Procedure . 87 H6 Ice Chiller Tank Monthly PM Procedures . 95 H6 Ice Chiller Tank Quarterly PM Procedures . 101 H6 Ice Chiller Tank Annual PM Procedures . 107 H7 Geothermal System Monthly PM Procedures . 113 H7 Geothermal System Annual PM Procedures . 119 H8 Water Source Heat Pump Monthly PM Procedures . 125 H8 Water Source Heat Pump Quarterly PM Procedures . 131 H8 Water Source Heat Pump Annual PM Procedures . 137 H9 Fan Coil System Quarterly PM Procedures . 143 H9 Fan Coil System Annual PM Procedures . 149 H10 Supply/Return Fan and Exhaust Fan Quarterly PM Procedures . 155 H10 Supply/Return Fan and Exhaust Fan Annual PM Procedures . 161 H11 Evaporative and Spot Coolers Monthly PM Procedures . 167 H11 Evaporative and Spot Coolers Quarterly PM Procedures .
    [Show full text]
  • ( Pdf 759.7 Kb ) PB-P PROSPEKT EN
    MODERATED- PRESSURE STEAM BOILERS PB-P PB-PP PB-P, PB-PP Series Moderated-pressure three-pass steam boilers combusting gaseous and liquid fuels In compliance with the requirements of standard ČSN EN 12 953 and directive EC 97/23 PBS INDUSTRY, a.s., Průmyslová 162, 674 01 Třebíč, Czech Republic IN: 269 79 888 Web: www.pbstre.cz Design The boiler body consists of a cylindrical shell, two reinforced bottoms, an asymmetrically bedded boiler Modifications flue, a water cooled inflective rear chamber and a nest The boilers can be supplied in a design with a of stay tubes of the second and the third pass. preparation for a future change to a warm-water or hot- The front inflective chamber is not cooled. It is closed water operation without interfering into the pressure with a door enabling cleaning of the generating assembly. surfaces. Boiler venting is provided by a flue gas BASIC TECHNICAL SPECIFICATION collector in the rear part of the boiler. Flue gas . Output 1 000 ÷ 30 000 kg/h discharge is realized via a chimney neck with an upper or rear outlet. Operation overpressure 6 ÷ 25 bar(g) Equipment . Heat transfer medium - saturated or superheated steam The boiler body is equipped with an instrument pipe with power supply regulation, a glass gauge, a . In compliance with technical requirements of ČSN manometer, a manostat to regulate the burner output EN 12953 and an emergency manostat. The boiler body also includes a neck for steam outlet, a feeding neck, a FUEL safety valve, deaeration, continual and periodical blow- down and a neck for level monitoring or the BOSB .
    [Show full text]
  • USCG ME Exam
    United States Coast Guard Marine Engineer Exam Questions Steam Knowledge Question Choice A Choice B Choice C Choice D Illustration BOOK Answer Number Question 13 1 D A bridge gage is normally used to determine turbine bearing oil clearance diaphragm tip clearance blade axial clearance bearing wear ____________. 13 2 B Coast Guard Regulations (46 CFR) requires machinery driving within the space outside of the space at the throttle station within the fireroom the fuel oil transfer and fuel oil service pumps to be fitted with a concerned concerned remote means of stopping that machinery ____________. 13 3 D If a ship is to be laid up for an indefinite period, the saltwater side left filled with saltwater left filled with saltwater drained and refilled with drained and dried out of the main condenser should be ____________. with the sea valves with the sea valves open saltwater after closing after closing the sea closed the sea valves valves 13 4 D According to U.S. Coast Guard Regulations (46 CFR), which of Fire pump Boiler Feed pump Fuel oil transfer pump All of the above the following pumps is required to have a pressure gage provided on the discharge side of the pump? 13 5 D Assume that steam has formed in a boiler in which all of the The steam pressure and The pressure will The pressure will remain The pressure will steam stop valves are closed, and the water level is held volume will remain increase and the volume constant and the volume increase and the specific constant.
    [Show full text]
  • Water Level Probe Info
    INSTALLATION, OPERATION AND MAINTENANCE MANUAL J Series (UK) Gas Fired Steam Boiler (including optional fully modulating burner) This manual must be available to the boiler operator at all times. JGASUK-IOMM-2015-2 Fulton Ltd Page II JGASUK-IOMM-2015-2 Fulton Ltd TABLE OF CONTENTS SECTION 1 - INTRODUCTION 4.10 Internal Inspection 32 1.1 General 1 4.11 Schedule of Operator Tests and Checks 33 1.2 Technical Data 1 4.11.1 Daily 34 4.11.2 Weekly-in addition 34 SECTION 2 - INSTALLATION 4.11.3 Monthly-in addition 34 2.1 General 3 4.11.4 Three Monthly-in addition 35 2.2 Siting 3 4.11.5 Six Monthly-in addition 35 2.3 Ventilation 4 4.11.6 Annually-in addition 37 2.4 Flue Outlet 4 4.12.1 Troubleshooting-boiler 38 2.5 Water Supply 6 4.12.2 Troubleshooting-feedwater pump 41 2.6 Blowdown Valve 7 4.12.3 Troubleshooting-burner control unit-LFL1 43 2.7 Main Steam Valve 8 4.13 Maintenance Log 45 2.8 Steam Safety Valves 8 2.9 Water Level Gauge Set (sight glass) 8 APPENDIX A - TI SHEETS 2.10 Gas Supply 8 APPENDIX B - WATER LEVEL PROBE INFO 2.10.1 Gas Valve with Pilot Gas Line 9 2.11 Electrical Requirements 9 APPENDIX C - MOTORISED HIGH/LOW CONTROL 2.12 Steam Pressure Gauge 9 1.1 General 57 2.13 Commissioning the Boiler 11 1.2 Operation 57 2.13.1 Boiler Inspection and Initial Firing 11 1.3 Additional Controls 58 2.13.2 Setting Burner Controls-low/high fire (40J-60J) 14 1.4 Commissioning 58 2.13.3 Setting Burner Controls-fully modulating (30J-60J) 14 1.4.1 Fuel Input Rates 58 2.14 Multi Bloc Gas Valves 15 1.4.2 Air Damper Motor - Factory Cam Settings 58 2.15
    [Show full text]
  • Lattner Boiler Company Model H.E
    Lattner Boiler Company Model H.E. Steam Boilers INSTRUCTION MANUAL January 2006 Lattner Boiler Company 1411 9th St. SW Cedar Rapids, IA 52404 T: (800) 345-1527 F: (319) 366-0770 E: [email protected] www.lattnerboiler.com Index General Description Page 4 A. Boiler Design ………………………………………………………………………….4 B. Boiler Connections ………………………………………………………………………….4 C. Boiler Trim ………………………………………………………………………….4 D. Fuel Burning System ………………………………………………………………………….5 E. Fuel Train ………………………………………………………………………….5 F. Control Panel ………………………………………………………………………….5 G. Combustion Safeguard ………………………………………………………………………….6 H. Factory Tests ………………………………………………………………………….6 I. Nameplates & Stamping ………………………………………………………………………….6 J. Guarantees ………………………………………………………………………….6 Section I: Installation Page 7 A. Unloading ………………………………………………………………………….7 B. Rigging ………………………………………………………………………….7 C. Placement of Boiler ………………………………………………………………………….7 D. Combustion Air ………………………………………………………………………….7 E. Stack ………………………………………………………………………….8 F. Boiler Shipped with Controls ………………………………………………………………………….8 Removed G. Steam Outlet ………………………………………………………………………….8 H. Blowdown Piping ………………………………………………………………………….8 I. Safety Valve ………………………………………………………………………….9 J. Gas Train Piping ………………………………………………………………………….9 K. Boiler Feed Systems ………………………………………………………………………...10 L. Electrical Connections ………………………………………………………………………...11 M. Before Firing the Boiler ………………………………………………………………………...11 N. Pressuretrols: Controller & Limit ………………………………………………………………………...11 O. Start Up of Standard Burners ………………………………………………………………………...12
    [Show full text]
  • FSZ Series Boiler Is a Cast Iron Oil-Fired Steam Boiler Designed for Use in Closed Heating Systems
    D ESIGNED TO L EAD FSZ Series Oil-Fired Steam Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler Models: • FSZ080 WARNING: Improper installation, • FSZ100 adjustment, alteration, service or • FSZ130 maintenance can cause property damage, injury, or loss of life. • FSZ160 For assistance or additional information, consult a qualified installer, service agency or the oil supplier. Read these instructions carefully before installing. Manufacturer of Hydronic Heating Products P.O. Box 14818 3633 I. Street Philadelphia, PA 19134 www.crownboiler.com WARNINGS FOR THE HOMEOWNER FOLLOW ALL INSTRUCTIONS and warnings unless alarms or other safeguards are in place to printed in this manual and posted on the boiler. prevent such damage INSPECT THE BOILER, BURNER AND DO NOT BLOCK AIR FLOW into or around the CONTROLS ANNUALLY. To keep your boiler safe boiler. Insufficient air may cause the boiler to and efficient, have a service technician follow the produce carbon monoxide or start a fire. Service checklist near the end of this manual. KEEP FLAMMABLE LIQUIDS AWAY from the IF YOU ARE NOT QUALIFIED to install or service boiler, including paint, solvents, and gasoline. boilers, do not install or service this one. The boiler may ignite the vapors from the liquids causing explosion or fire. THE BOILER MAY LEAK WATER at the end of its useful life. Be sure to protect walls, carpets, KEEP CHILDREN AND PETS away from hot and valuables from water that could leak from the surfaces of the boiler, boiler piping, and vent pipe. boiler. CARBON MONOXIDE (CO) is an odorless, deadly PROTECT YOUR HOME IN FREEZING gas that may be introduced into your home by WEATHER.
    [Show full text]