Transactions, SMiRT-25 Charlotte, NC, USA, August 4-9, 2019 Division III Analysis on the Thermal Striping and Thermal Shock of the Lower Head of Central Measuring Shroud in a Fast Reactor Zheng Shu 1, Lu Daogang 1, Cao Qiong 1 1School of Nuclear Science and Engineering, Beijing Key Laboratory of Passive Nuclear Safety Technology for Nuclear Energy, North China Electric Power University, Beijing 102206, China (
[email protected]) ABSTRACT The central measuring shroud, as an important in-vessel component, contains the conduits of control rod and a variety of measuring equipment. The distance between the core outlet and the lower head of central measuring shroud (LHCMS), which is located above the core outlet, is only 500mm. Therefore, the LHCMS is affected by the core coolant for a long period, especially the temperature effects of the following two types. Firstly, under the operating condition of the sodium-cooled fast reactor, the uneven distribution of the core power causes the phenomenon of thermal striping, which may cause large stress. In addition, under the scram condition, the coolant temperature at the core outlet is sharply reduced due to the decrease of the core power, inducing the phenomenon of thermal shock that may induce large stress. Therefore, stress analysis of the LHCMS under the operating condition and scram condition is very necessary. In the paper, the simulation first established the finite element model of the LHCMS, and then calculated the thermal stress of the LHCMS according to the temperature fluctuation curve and the scram temperature curve. The results show that the temperature field under thermal shock changes dramatically with time, while the temperature field under thermal striping changes relatively slowly with time.