Wall Design for Out of Plane Wind Loads

October, 2015 Day’s Overview

• Load Path Overview • Introducon to Codes & Standards • Diaphragm Design and Detailing • Shear Design and Detailing • Prescripve Design Opons for Systems • Upli including Combined Shear • Wall Design • Mul-Story Consideraons

Designing Wood Wind Load Paths

WIND SURFACE LOADS ON WALLS Wind Loads

Uniform surface wind loads generally increase with height

If wind loads vary with building height, common to use higher wind load over a single story or building ASCE 7-10 Fig. 27-6.1 Wall Design Consideraons

Panels Hinges L/d Rao Unbraced Length Wall Veneer Wind only loading C&C Design Properes Loads into WSP

Wind loads are transferred to wall studs through wood structural panels (sheathing) APA Tech. Note Q225G Which wall is going to withstand high winds?

TOP PLATE

L/D < 50 2x6: 22’-11” 2x4: 14’-7” Gable End Wall Hinge Gable End Bracing Details

• AWC’s Wood Frame Construcon Manual Gable End Bracing Details

framing may require cross bracing details at gable end Full Height Studs at Gable End Walls

• If no openings in gable end wall exist, can design studs to span from floor/foundaon to roof (varying stud heights). May require closer stud spacings at taller porons of wall Gable End Walls with Openings Gable End Walls with Openings Gable End Wall Girts & Jambs

Horizontally Vercally spanning spanning girts jambs

• Oen gable end walls are locaons of large

• Horizontally spanning member in plane of wall breaks stud length, provides allowable opening Determining Unbraced Length

What is the unbraced

length, lu ? Strong & weak axis Does Gypsum Prevent Weak Axis Buckling

NDS Commentary: “Experience has shown that any code allowed thickness of gypsum board, hardwood , or other interior finish adequately fastened directly to studs will provide adequate lateral support L of the stud across its thickness irrespecve of the type or thickness of exterior sheathing and/or finish used.” Intermediate Wall Stud Blocking Calculang Deflecon – IBC Table 1604.3

For Δ of most brile finishes use l/240 For C&C pressures a 30% load reducon is allowed for Δ only (IBC Table 1604.3 footnote f) TABLE 1604.3 DEFLECTION LIMITSa, b, c, h, i CONSTRUCTION L S or W f D + Ld,g Roof members:e Supporting plaster l /360 l /360 l /240 Supporting nonplaster ceiling l /240 l /240 l /180 Not supporting ceiling l /180 l /180 l /120 members l /360 — l /240 Exterior walls and interior partitions: With brittle finishes — l /240 — With flexible finishes — l /120 — Farm — — l /180 Greenhouses — — l /120 f. The wind load is permied to be taken as 0.42 mes the "component and f. The wind load is permitted to be taken as 0.7 times the “component and cladding” loads for the purpose of determining deflecon limits herein. cladding” loads for the purpose of determining deflection limits herein. Wood Studs with Brick Veneer - Deflecon

IBC Table 1604.3: min. wall deflecon with brile finishes = L/240 Brick Industry Associaon recommends much stricter limits Structure Magazine May 2008 arcle, Harold Sprague BIA Tech Note 28

Example: Large Diamond Retailer

22’ tall wood framed walls. Assume studs 16” o.c. 130 mph Exposure B Least Horizontal Dim. = 64 . External Pressure Coefficients – Wall Zones 4 & 5 a = Lesser of: • 10% least horizontal dimension (LHD) 64’*0.1 = 6.4’ • 0.4h = 0.4*22 = 8.8’. But not less than: • 0.04 LHD=2.6’ or 3’

Use a = 6.4’ for zone 5 Effecve Wind Area

For wind design, tributary area does not necessarily = effecve wind area

Effecve Wind Area (EWA) - Two cases: • Area of building surface contribung to force being considered (tributary area) • Long and narrow area (wall studs, roof ): width of effecve area may be taken as 1/3 length; increases effecve area, decreases load (per ASCE 7-10 secon 26.2 commentary); EWA = L2/3 Effecve Wind Area Example

Trib. A = (22)(1.33) = 29 2 EWA = 222/3 = 161 2

22’-0” 22’-0”

Studs @ Studs @ 16” o.c. 16” o.c. External Pressure Coefficients - Walls

Assume wall studs are 22’ long EWA = h2/3 = 161 2 Zone 4:

GCpf = -0.89

GCpi = -0.18 (Table 26.11-1) Zone 5:

GCpf = -1.0

ASCE 7-10 Figure 30.4-1

Running the numbers – Zone 4

• GCpf: 0.89 (Figure 30.4-1) • GCpi: 0.18 (Table 26.11-1) 2 • qh = 0.00256KzKztKdV

§ Kh : 0.70 - Table 30.3-1

§ Kzt : 1.00 - Figure 26.8-1 § Kd : 0.85 - Table 26.6-1 § V: 130 mph

• qh = 25.74psf • p = 25.74psf(0.89+0.18) = 27.54psf • 0.6W = 0.6(27.54) = 16.52psf

Lumber Design Properes

Design Properes from NDS Supplement.

Assume 2x8 Douglas Fir- Larch #2 Studs, 16” o.c. Repeve Member adjustment = 1.25 Size Factor = 1.2 Duraon of Load = 1.6

Lumber Design Properes

Note on stud repeve member factor:

NDS secon 4.3.9: CR = 1.15

SDPWS Table 3.1.1.1 allows larger CR factors for studs in bending, 16” spacing max, interior covered with min. ½” gypsum, exterior covered with min. 3/8” WSP, other fastener requirements DESIGN PROPERTIES

Fb (psi) 900 NDS Supp. Table 4A

CD 1.6 NDS Table 2.3.2

CR 1.25 SDPWS Table 3.1.1

CF 1.2 NDS Supp. Table 4A E (psi) 1600000 NDS Supp. Table 4A 3 Sx (in ) 13.1 Calculated NDS 3.3-4 I (in4) 47.6 Calculated NDS 3.3-3 So is our stud going to work?

Two of the most crical design parameters are bending and deflecon.

IBC Table 1604.3 footnote f

Studs work! Running the numbers – Zone 5

• GCp: 1.00 (Figure 30.4-1) • GCpi: 0.18 (Table 26.11-1) 2 • qh = 0.00256KzKztKdV

§ Kh : 0.70 - Table 30.3-1

§ Kzt : 1.00 - Figure 26.8-1 § Kd : 0.85 - Table 26.6-1 § V: 130 mph

• qh = 25.74psf • p = 25.74psf(1.0+0.18) = 30.37psf • 0.6W = 0.6(30.37) = 18.22psf

What about corner zones?

IBC Table 1604.3 footnote f

Deflecon check no good – soluon: reduce loads on each stud 12” Stud Spacing

Since stud depth cannot be increased consider reducing stud spacing to 12” in all Zone 5 areas:

IBC Table 1604.3 footnote f

Studs work! – Use 2x8 @ 16” o.c. typical, use 2x8 @ 12” o.c. in corners (Zone 5 areas) Wall Design Consideraons

For tall walls while it is less likely for combined bending and axial to control D, L, S • Main Wind Force Loads may be ulized • Load combinaons (ASCE 7 Chpt 2) for: W § wind + dead or § dead + 0.75 live + 0.75 roof live (or snow) AWC discusses this topic: hp://www.awc.org/pdf/codes-standards/publicaons/ archives/AWC-Consideraons-0310.pdf

Wall Stud Design Aid

Western Wood Products Associaon (WWPA) Design Suite: hp://www.wwpa.org/TECHGUIDE/DesignSoware/tabid/859/Default.aspx

Quesons?