Model 5030I SHARP Instruction Manual Synchronized Hybrid Ambient Real-Time Particulate Monitor Part Number 108148-00 25Mar2014
Total Page:16
File Type:pdf, Size:1020Kb
Model 5030i SHARP Instruction Manual Synchronized Hybrid Ambient Real-time Particulate Monitor Part Number 108148-00 25Mar2014 © 2011 Thermo Fisher Scientific Inc. All rights reserved. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific Air Quality Instruments 27 Forge Parkway Franklin, MA 02038 1-508-520-0430 www.thermo.com/aqi WEEE Compliance This product is required to comply with the European Union’s Waste Electrical & Electronic Equipment (WEEE) Directive 2002/96/EC. It is marked with the following symbol: Thermo Fisher Scientific has contracted with one or more recycling/disposal companies in each EU Member State, and this product should be disposed of or recycled through them. Further information on Thermo Fisher Scientific’s compliance with these Directives, the recyclers in your country, and information on Thermo Fisher Scientific products which may assist the detection of substances subject to the RoHS Directive are available at: www.thermo.com/WEEERoHS. Thermo Fisher Scientific WEEE Compliance About This Manual This manual provides information about installing, operating, maintaining, and servicing the Model 5030i Synchronized Hybrid Ambient Real-time Particulate (SHARP) Monitor. It also contains important alerts to ensure safe operation and prevent equipment damage. The manual is organized into the following chapters and appendices to provide direct access to specific operation and service information. ● Chapter 1 “Introduction” provides an overview of product features, describes the principle of operation, and lists the specifications. ● Chapter 2 “Installation” describes how to unpack, setup, and startup the instrument. ● Chapter 3 “Operation” describes the front panel display screens, the front panel pushbuttons, and the menu-driven firmware. ● Chapter 4 “Calibration” provides the procedures for calibrating the analyzer and describes the required equipment. ● Chapter 5 “Preventive Maintenance” provides maintenance procedures to ensure reliable and consistent instrument operation. ● Chapter 6 “Troubleshooting” presents guidelines for diagnosing analyzer failures, isolating faults, and includes recommended actions for restoring proper operation. ● Chapter 7 “Servicing” presents safety alerts for technicians working on the analyzer, step-by-step instructions for repairing and replacing components, and a replacement parts list. It also includes contact information for product support and technical information. ● Chapter 8 “System Description” describes the function and location of the system components, provides an overview of the firmware structure, and includes a description of the system electronics and input/output connections. ● Chapter 9 “Optional Equipment” describes the optional equipment that can be used with this analyzer. ● Chapter 10 “Model 5014i to 5030i Upgrade Procedures” describes the 5014i to 5030i upgrade procedures. ● Appendix A “Warranty” is a copy of the warranty statement. Thermo Fisher Scientific Model 5030i SHARP Instruction Manual i About This Manual Safety ● Appendix B “C-Link Protocol Commands” provides a description of the C-Link protocol commands that can be used to remotely control an analyzer using a host device such as a PC or datalogger. ● Appendix C “MODBUS Protocol” provides a description of the MODBUS Protocol Interface and is supported both over RS- 232/485 (RTU protocol) as well as TCP/IP over Ethernet. ● Appendix D “Gesytec (Bayern-Hessen) Protocol” provides a description of the Gesytec (Bayern-Hessen or BH) Protocol Interface and is supported both over RS-232/485 as well as TCP/IP over Ethernet. ● Appendix E “ESM Protocol Commands” provides a description of the ESM Protocol commands (from the prior 5030 platform) that can be used to remotely control an analyzer using a host device such as a PC or datalogger. Safety Review the following safety information carefully before using the analyzer. This manual provides specific information on how to operate the analyzer, however, if the analyzer is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Safety and Equipment This manual contains important information to alert you to potential safety hazards and risks of equipment damage. Refer to the following types of Damage Alerts alerts you may see in this manual. Safety and Equipment Damage Alert Descriptions Alert Description DANGER A hazard is present that could result in death or serious personal injury if the warning is ignored. ▲ WARNING A hazard or unsafe practice could result in serious personal injury if the warning is ignored. ▲ CAUTION A hazard or unsafe practice could result in minor to moderate personal injury if the warning is ignored. ▲ Equipment Damage A hazard or unsafe practice could result in property damage if the warning is ignored. ▲ Safety and Equipment Damage Alerts in this Manual Alert Description WARNING The Model 5030i is supplied with a three-wire grounded power cord. Under no circumstances should this grounding system be defeated. ▲ ii Model 5030i SHARP Instruction Manual Thermo Fisher Scientific About This Manual Safety and Equipment Damage Alerts Alert Description If the equipment is operated in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. ▲ The service procedures in this manual are restricted to qualified service personnel only. ▲ The detector assembly should be replaced by a qualified technician knowledgeable in dealing with radiation precautions. By removing the detector assembly, the C-14 radioactive source is partially exposed. Safety glasses must be worn during this replacement procedure. The amount of C-14 meets the USNRC regulations as an exempt amount of radioactive source <100 μCi. ▲ The detector pre-amp assembly has a power backup built in. “DO NOT OPEN” caution handeling. Backup power will dissipate after 8 hours. ▲ CAUTION The detector window is very fragile. Handle with great care and do not wipe or touch the window. Furthermore, do not touch the solder cable connection (electrode) with your bare fingers. The oils from your skin can damage the detector. ▲ Safety glasses must be worn while replacing the detector assembly. ▲ If the LCD panel breaks, do not let the liquid crystal contact your skin or clothes. If the liquid crystal contacts your skin or clothes, wash it off immediately using soap and water. ▲ Equipment Damage Do not attempt to lift the analyzer by the cover or other external fittings. ▲ Some internal components can be damaged by small amounts of static electricity. A properly grounded antistatic wrist strap must be worn while handling any internal component. ▲ Disconnect the serial cable before changing the RS-232 and RS-485 selection to prevent damage to any equipment currently connected to the analyzer. ▲ Do not use solvents or other cleaning products to clean the outside case. ▲ Do not remove the LCD panel or frame from the LCD module. ▲ The LCD polarizing plate is very fragile, handle it carefully. ▲ Do not wipe the LCD polarizing plate with a dry cloth, as it may easily scratch the plate. ▲ Do not use alcohol, acetone, MEK or other ketone based or aromatic solvent to clean the LCD module, but rather Thermo Fisher Scientific Model 5030i SHARP Instruction Manual iii About This Manual Electrical/Safety Certifications Alert Description use a soft cloth moistened with a naphtha cleaning solvent. ▲ Do not place the LCD module near organic solvents or corrosive gases. ▲ Do not shake or jolt the LCD module. ▲ Electrical/Safety The product has been tested and has been documented to be in compliance Certifications with the following U.S. and Canadian safety standards: UL Standard 61010-1:2004 2nd Edition CAN/CSA C22.2 No. 1010-1:2004 2nd Edition IEC 61326-2-3: 2006 Thermo Fisher Scientific certifies that this product operates in compliance with the EC Directive 89/336/EEC in reference to electrical emissions and immunity. Specifically, the equipment meets the requirements of EN 61326-1:1998 for Immunity and Emissions. In addition, the hardware has been tested for personal or fire safety hazards in accordance with EN61010- 1:2001 (Safety) in fulfillment of EC Directive 73/23/EEC. FCC Compliance Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note This equipment has been tested and found to comply within the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his or her own expense. ▲ iv Model 5030i SHARP Instruction Manual Thermo Fisher Scientific About This Manual WEEE Symbol WEEE Symbol The following symbol and description identify the WEEE marking used on the instrument and in the associated documentation. Symbol Description Marking of electrical and electronic equipment which applies to waste electrical and electronic equipment falling under