7000 Series Capillary Rheometers & Labkars Software
Total Page:16
File Type:pdf, Size:1020Kb
DYNISCO 7000 Series Capillary Rheometers & LabKARS Software Version: 2.4 User Guide This manual was produced using Doc-To-Help®, by WexTech Systems, Inc. WexTech Systems, Inc. 310 Madison Avenue, Suite 905 New York, NY 10017 1-800-WEXTECH Notice This manual contains descriptions, drawings and specifications for a Dynisco Polymer Test Systems Product. Equipment or products made prior to or subsequent to the publication date of this manual may have parts, features, options or configurations that are not covered in this manual. Specifications contained herein are subject to change by Dynisco Polymer Test Systems without prior notice. Dynisco Polymer Test Systems is not responsible for errors or omissions that may be contained herein or for incidental or consequential damages in connection with the furnishing or use of this information. The information contained in this manual is the property of Dynisco Polymer Test Systems, unless otherwise stated. Thank you to all Dynisco Polymer Test Systems employees for their input into this manual. Comments or suggestions for possible improvement to the manual are appreciated and may be sent to the following location: Dynisco Polymer Test Systems Attention: Technical Publications Department 38 Forge Parkway Franklin, MA 02038-3134 or Email: www.Dynisco.com Contents INTRODUCTION ................................................................................................... 7 1. How to use this manual ................................................................................. 7 2. Typographic Conventions .............................................................................. 7 3. How to Contact DYNISCO POLYMER TEST................................................ 8 GETTING STARTED ............................................................................................. 9 1. Uncrating and Setup ...................................................................................... 9 2. Bench Requirements and Placement .............................................................. 9 3. Unpacking the Rheometer.............................................................................. 9 4. Power connection ........................................................................................ 10 5. Computer Connection .................................................................................. 10 6. Laser Micrometer connection (optional) ..................................................... 10 7. Model 7000 .................................................................................................. 10 8. Model 7001 .................................................................................................. 10 9. Model 7002 .................................................................................................. 10 10. Load Cell assembly (models 7000 & 7001) ............................................... 11 11. Connecting the Barrel Pressure Transducer plug (models 7001 & 7002) 11 12. Powering up the Rheometer ....................................................................... 12 13. Software installation .................................................................................. 12 14. E-mail Software Upgrades ........................................................................ 13 16. Rheometer Firmware and Firmware Upgrades ........................................ 14 17. Die Swell Laser Installation ...................................................................... 15 SAFETY ................................................................................................................. 17 1. Use Gloves - Its Hot! ................................................................................... 17 2. Electrical Hazard ........................................................................................ 17 3. Calibration Thermometers use Mercury (Models 7000, 7001 & 7002) ...... 17 4. Pinch Points. ................................................................................................ 18 5. Fumes from Materials ................................................................................. 18 6. Before Testing Safety Check ........................................................................ 18 7. Purging the rheometer ................................................................................. 19 8. Putting the Die(s) in the Barrel ................................................................... 19 9. Loading the Sample ..................................................................................... 19 10. Starting the Purge. ..................................................................................... 20 11. Cleaning Up ............................................................................................... 20 TEST DRIVE ......................................................................................................... 22 1. Time Sweep Test .......................................................................................... 22 2. Starting Lab KARS and setting up the rheometer. ....................................... 22 3. Performing the test ...................................................................................... 22 4. The Second Test: A Rate Sweep ................................................................... 23 5. Cleaning Up a really Big Mess. ................................................................... 23 LAB KARS ............................................................................................................. 25 DYNISCO POLYMER TEST LCR 7000 Series Capillary Rheometers Introduction • 3 LABKARS 7000 and 7001 ................................................................................ 25 LABKARS 7002................................................................................................ 25 LABKARS OPERATIONS ........................................................................................................... 25 PC Requirements & Port Settings.................................................................... 26 Starting LabKARS or LabKARS Set-Up .......................................................... 28 Creating a LabKARS Icon ............................................................................... 28 Security/Pasword Protection ........................................................................... 29 LabKARS Security Access Levels .................................................................... 29 Database Record Manipulation Keys .............................................................. 30 Before The Start of any Run ............................................................................. 30 Moving around LabKARS ................................................................................ 31 SET UP TEST PAGE ....................................................................................................................... 31 Setting up a new test ........................................................................................ 32 Data Point Setup. ............................................................................................. 33 Data Acquisition Mode .................................................................................... 35 Start Position ................................................................................................... 35 Die Selection .................................................................................................... 36 Generic Prerun Check List .............................................................................. 36 Test Setup Example .......................................................................................... 37 HAMA LASER MICROMETER.................................................................................................. 38 Starting up and testing the laser ...................................................................... 38 HAMA Laser Calibration ................................................................................ 40 RHEOMETER CONTROL SCREEN ............................................................................................. 40 Control Buttons................................................................................................ 41 Real-time Data during the Test ........................................................................ 42 Test Automation Server.................................................................................... 43 PLOTTING AND ANALYZING YOUR DATA ............................................................................ 44 Plotting ............................................................................................................ 44 Merging ........................................................................................................... 44 Single Run Analyze / Database ........................................................................ 45 Plotting ............................................................................................................ 46 From Database/ Filters Option ....................................................................... 46 From Single Run/Modify Screen ...................................................................... 46 Modifying Plots using the Plot Toolbar ........................................................... 46 Appending and Overlaying Plots ..................................................................... 48 Copying