LIST OF RECOMMENDATION (08/2005) QUANTUM HYDROMETRIE GMBH
CLIENT YEAR WIDTH TYPE PATHS SYSTEM/FREQUENCY/TRANSD...R. RANGE
EGYPT
Ministry of Water Resources Mubarak Pumpstation 2001 2,7 m 21 canals 2 AF810/200kHz/TC2024 0 to 20 m/s
CHINA
Min. f. Wirtschaft BRB Heituwa Wetland 2004 2,0 m 2 canals 2 AF16-40/200kHz/TC2153 0 to 4 m/s
DENMARKENMARK
Sonderjyllands Amt Vidaa Sluse/Tonder 1999 15 m canal 3 AF860/200kHz/TC2024 0 to 4 m/s BallumSluse 2000 10 m canal 2 AF860/200kHz/TC2024 0 to 4 m/s River Hoptrup 2004 16 m canal 2 AFC8-40/200kHz/TC2153 0 to 2 m/s Bjornsholm 2004 5 m river 2 AFC8-40/200kHz/TC2153 -10 to 10 m/s
FRANCE
Agence de léau Artois-Picardie L‘Escaut à Fresnes sur Escaut 2000 50 m waterway 1 AF860/200kHz/TC2024 -1 to 2 m/s L‘Escaut à Mortagne du Nord 2000 90 m waterway 2 AF860/200kHz/TC2024 -1 to 2 m/s La Scarpe à Thun 2000 25 m waterway 2 AF860/200kHz/TC2024 -1 to 2 m/s La Sambre au Pont de Marpent 2000 24 m waterway 2 AF860/200kHz/TC2024 -1 to 2 m/s La Deûle à Quesnoy 2000 57 m waterway 2 AF860/200kHz/TC2024 -1 to 2 m/s La Marque à Marquette 2000 20 m waterway 2 AF860/200kHz/TC2024 -1 to 2 m/s La Lys á Menen 2000 60 m waterway 2 AF860/200kHz/TC2024 -1 to 2 m/s La Deûle à Don 2000 58 m waterway 2 AF860/200kHz/TC2024 -1 to 2 m/s La Deûle á Douai 2000 35 m waterway 2 AF860/200kHz/TC2024 -1 to 2 m/s La Scarpe à Brébières 2000 22 m waterway 2 AF860/200kHz/TC2024 -1 to 2 m/s Le Canal du Nord Sensées 2000 48 m waterway 2 AF860/200kHz/TC2024 -1 to 2 m/s La Lys à Aire sur la Lys 2000 20 m waterway 1 AF860/200kHz/TC2024 -1 to 2 m/s Diren 2001 24 m river 2 AFC860/200kHz/TC2024 0 to 2 m/s
Service de la Navigation Strasbourg/Rhein 1999 350 m river 2 AF82000/28kHz/TC2115 0 to 4 m/s
Quantum Hydrometrie GmbH Gesellschaft für Meß- und Systemtechnik GmbH Zossener Straße 55, D-10961 Berlin, Germany Tel:+49 (0)30 698 110-0 E-mail: [email protected] Fax:+49 (0)30 698 110-99 Internet: www.quantum-hydrometrie.de CLIENT YEAR WIDTH TYPE PATHS SYSTEM/FREQUENCY/TRANSD...R. RANGE
GERMANY
Alzwerke Alzkanal 1999 20 m Concrete channal 1 AF860/200kHz/TC2024 0 to 4 m/s BERG. RH. WASSERVERB... Itterbach/Kuckesberg 2002 2,5 m canal 2/Bern AFC860/200/TC2153/2111 0 to 4 m Eselsbach 2004 2,5 m canal 3 AFC8-40/200/TC2153/2111 0 to 4 m
Berliner Wasser Betriebe Stolpe 1994 1,2 m pipe 4 AF810/200kHz/TC2024 -1 to 2 m/s RRB Rudow 1999 1,6 m Concrete channal 2 AF810/200kHz/TC2024 0 to 1 m/s
Emschergenossenschaft Dortmund/Emscher 1997 5 m river 3 AF860/200kHz/TC2024 0 to 3 m/s Bottrop/Berne 1998 4 m river 2 AF860/200kHz/TC2024 0 to 2 m/s Rotbach/Zulauf 2001 10 m river 2 AF860/200kHz/TC2024 0 to 3 m/s Rotbach/Ablauf 2001 10 m river 2 AF860/200kHz/TC2024 0 to 3 m/s Dattelner Mühlbach km 2,3 2004 8 m canal 2 AFC8-40/200kHz/TC2153 0 to 4 m/s Dattelner Mühlbach km 7,4 2004 8 m canal 2 AFC8-40/200kHz/TC2153 0 to 4 m/s Dümmerbach 2004 8 m canal 3 AFC8-40/200kHz/TC2153 0 to 4 m/s Benninghausen 2004 10 m canal 2 AF860/200kHz/TC2153 0 to 4 m/s Kamen 2005 10 m river 2 AFC8-40/200kHz/TC2153 -10 to 10 m/s Lünen 2005 15 m river 4 AF8-40/200kHz/TC2153 -10 to 10 m/s
GD Besigheim Besigheim/Enz 1998 35 m river 2 AF860/200kHz/TC2024 0 to 4 m/s Bietigheim/Metter 1999 11 m river 3 AF860/200kHz/TC2024 0 to 3 m/s
GD Ellwangen Bopfingen/Sechta 2001 10 m river 2 AF860/200kHz/TC2024 0 to 4 m/s Geislingen/Bühler 2001 15 m river 4 AF860/200kHz/TC2024 0 to 4 m/s Schwäbisch-Gmünd/Rems 2001 20 m river 4 AF860/200kHz/TC2024 0 to 4 m/s
GD Freudenstadt Calmbach/Enz 1999 35 m river 2 AF860/200kHz/TC2024 0 to 4 m/s Dillweißenstein/Nagold 1999 45 m river 4 AF860/200kHz/TC2024 0 to 4 m/s Neuenbürg/Enz 1999 25 m river 4 AF860/200kHz/TC2024 0 to 4 m/s Wildberg/Nagold 1999 45 m river 4 AF860/200kHz/TC2024 0 to 4 m/s Calmbach Mitte/Enz 2000 20 m river 2 AF860/200kHz/TC2024 0 to 4 m/s
GD Heidelberg Ziegelhausen/Neckar 1999 80 m river 3 AF860/200kHz/TC2024 0 to 4 m/s
Quantum Hydrometrie GmbH Gesellschaft für Meß- und Systemtechnik GmbH Zossener Straße 55, D-10961 Berlin, Germany Tel:+49 (0)30 698 110-0 E-mail: [email protected] Fax:+49 (0)30 698 110-99 Internet: www.quantum-hydrometrie.de CLIENT YEAR WIDTH TYPE PATHS SYSTEM/FREQUENCY/TRANSD...R. RANGE
GD Karlsruhe Bruchsal/Saalbach 2001 10 m river 3 AF860/200kHz/TC2024 0 to 4 m/s Ubstadt/Krainbach 2001 5 m river 2 AF860/200kHz/TC2024 0 to 4 m/s
GD Kirchheim unter Teck Salach/Fils 2001 20 m river 3 AF860/200kHz/TC2024 0 to 4 m/s
GD Künzelsau Grünsfeld/Wittigbach 2000 7 m river 2 AF860/200kHz/TC2024 0 to 4 m/s Ohrnberg/Ohrn 2000 10 m river 3 AF860/200kHz/TC2024 0 to 4 m/s
GD Offenburg BAB 5/Kinzig 2001 40 m river 4 AF860/200kHz/TC2024 0 to 4 m/s Biberach/Kinzig 2001 30 m river 4 AF860/200kHz/TC2024 0 to 4 m/s
GD Projektgruppe Lahr Kulturwehr Kehl/Rhein 1996 350 m river 2 AF81000/33kHz/TC2084 0 to 4 m/s
GD Rottweil Villingen/Brigach 2001 30 m river 2 AF860/200kHz/TC2024 0 to 4 m/s Aach/Aach 2001 15 m river 4 AF860/200kHz/TC2024 0 to 4 m/s
GD Ulm Ulm/Blau 2000 30 m river 2 AF860/200kHz/TC2024 0 to 4 m/s Tübingen/Ammer 2001 20 m river 6 AF860/200kHz/TC2024 0 to 4 m/s Tübingen/Neckar 2001 80 m river 2 AF860/200kHz/TC2024 0 to 4 m/s
GD Waldshut-Tiengen Dreisam/Ebnet 2000 30 m river 4 AF860/200kHz/TC2024 0 to 4 m/s Oberambringen/Möhlin 2001 10 m river 2 AF860/200kHz/TC2024 0 to 4 m/s Sankt Blasien/Alb 2001 30 m river 3 AF860/200kHz/TC2024 0 to 4 m/s Tiengen/Wutach 2001 45 m river 2 AF860/200kHz/TC2024 0 to 4 m/s
ISAR-Amperwerke Höllriegelskreuth 1996 15 m canal 1 AF860/200kHz/TC2024 0 to 4 m/s
LHW Sachsen-Anhalt Aken 2004 10 m river 2 AFC8-40/200KHZ/TC2153 -10 to 10 m/s Arland 2005 25 m river 4 AF8-40/200KHZ/TC2153 Aschersleben 2004 10 M river 4 AF 8-40/200KHZ/TC2153 0 to 3 m/s Baalberge 2004 8 M river 2 AF 8-40/200KHZ/TC2153 0 to 3 m/s Demker/Tanger 2001 10 m river 2 AFC860/200KHZ/TC2024 0 to 3 m/s Dobbrun 2005 24 m river 3 AF8-40/200KHZ/TC2024 -10 to 10 m/s Frankleben 2002 2,5 m canal 1 AF860/200KHZ/TC2153 0 to 1,5 m/s
Quantum Hydrometrie GmbH Gesellschaft für Meß- und Systemtechnik GmbH Zossener Straße 55, D-10961 Berlin, Germany Tel:+49 (0)30 698 110-0 E-mail: [email protected] Fax:+49 (0)30 698 110-99 Internet: www.quantum-hydrometrie.de CLIENT YEAR WIDTH TYPE PATHS SYSTEM/FREQUENCY/TRANSD...R. RANGE
Görsbach/Helme 1998 15 m river 3 AF860/200kHz/TC2024 0 to 3 m/s Hagenau/Biese 1998 20 m river 2 AF860/200kHz/TC2024 0 to 3 m/s Mühlstedt 2004 7 m river 2 AFC8-40/200KHZ/TC2153 -10 to 10 m/s Saukopf/Helme 1999 17 m river 4 AF860/200kHz/TC2024 0 to 2 m/s Staßfurt 2003 20 m river 4 AFC 8-40/200kHZ/TC2153 -10 to 10 m/s Stollberg/Thyra 2002 6 m river 3 AFC 860/200kHz/TC2153 0 to 4 m/s Zeitz 2005 25 m river 4 AF 8-40/200KHZ/TC2153 -10 to 10 m/s
Talsperrenbetrieb Sachsen- Anhalt Königshütte/Bode 1999 3,5 m tunnel 2 AF810/200kHz/TC2024 0 to 3 m/s Wendefurth 2002 12 river 2 AF 860/200kHz/TC2153 0 to 4 m
Landesumweltamt Brandenburg Eisenhüttenstadt 1996 10 m canal 2 AF810/200kHz/TC2111 0 to 3 m/s Bliesdorf 1998 14 m river 2 AF810/200kHz/TC2024 0 to 2 m/s Neutornow 1998 9 m canal 2 AF810/200kHz/TC2024 0 to 2 m/s
LANU Flintbek Kellinghusen 2002 20 m river 4 AFC 860/200kHZ/TC2153 -1 to 3 m/s
LANU Schleswig-Holstein Friedrichstadt/Spülschleuse 1998 7 m canal 2 AF860/200kHz/TC2024 -1 to 3 m/s Friedrichstadt/Treene 1998 40 m river 2 AF860/200kHz/TC2024 -1 to 3 m/s Treia/Treene 1998 15 m river 2 AF860/200kHz/TC2024 -1 to 3 m/s Wensin 2001 5,0 m river 2 AFC860/200kHz/TC2024 0 to 1,5 m/s Herrenmühle 2001 10,5 m river 2 AFC/860/200kHz/TC2024 0 to 1,5 m/s Bad Schwartau 2001 10 m river 2 AFC 860/200kHz/TC2024 0 to 1,5 m/s Moisling/ Trave 2002 35 m river 2 QAFC 860/200kHz/TC2153 -1 to 3 m/s Pohnsdorf 2002 6 m river 4 AFC 860/200 kHz/TC2153 0 to 4 m/s Nordfeld/ Eider 2002 5x5 m Sluice 6 AF 860/200kHz/TC2024 -1 to 4 m Dahmer Schleuse 2004 29 m river 2 AFC 8-40/200kHz/TC 2153 -10 to 10 m/s Meldorf 2004 20 m river 2 AFC 8-40/200kHz/TC 2024 -10 to 10 m/s
NLWK Sulingen Schäferhof/Hunte 2001 10 m river 2 AF860/200kHz/TC2024 -1 bis 3 m/s
Lippeverband Oberhausen/Emscher 2002 50 m river 2 AF810/200kHz/TC2111 -1 to 3 m/s Hamm 2002 30 m river 3 AFC 860/200kHz/TC2153 -1 to 3 m/s Benninghausen/Trotzbach 2004 5 m river 2 AFC 860/200kHz/TC 2153 -10 to 10 m/s Dinslaken/Rotbach 2004 16 m river 2 AFC8-40/200KHZ/TC2153 -10 to 10 m/s Marl 2005 16 m river 3 AFC8-40/200KHZ/TC2153 -10 to 10 m/s
Quantum Hydrometrie GmbH Gesellschaft für Meß- und Systemtechnik GmbH Zossener Straße 55, D-10961 Berlin, Germany Tel:+49 (0)30 698 110-0 E-mail: [email protected] Fax:+49 (0)30 698 110-99 Internet: www.quantum-hydrometrie.de CLIENT YEAR WIDTH TYPE PATHS SYSTEM/FREQUENCY/TRANSD...R. RANGE
Ruhrverband Biggetalsperre 1997 4 m tunnel 2 AF810/200kHz/TC2111 0 to 1,5m/s Fröndenberg/Ruhr 1998 35 m river 1 AF860/200kHz/TC2024 0 to 4 m/s Essen Werden/Ruhr 2000 60 m river 2 AF860/200kHz/TC2024
SEBA Hydrometrie Schorndorf 2002 20 m river 2 AF 860/200kHz/TC2153 0 to 4 m/s
SenStadt Berlin Freybrücke 1994 60 m river 2 AF81000/33kHz/TC2084 -1 to 3 m/s Stößensee 1994 20 m river 2 AF860/200kHz/TC2024 -1 to 3 m/s Prinz-Friedrich-Leopold-Kanal 1994 15 m canal 1 Af860/200kHz/TC2024 -1 to 3 m/s Oberschleuse 1995 15 m canal 1 AF860/200kHz/TC2024 -1 to 3 m/s Sophienwerder 1995 35 m river 4 AF81000/33kHz/TC2084 -1 to 3 m/s Köpenick 1996 80 m river 2 AF81000/33kHz/TC2084 -1 to 3 m/s Landwehrkanal 1996 25 m canal 1 Af860/200kHz/TC2024 -1 to 3 m/s Oberhavel 1997 60 m river 2 AF81000/33kHz/TC2084 -1 to 2 m/s Nordgraben 1998 25 m canal 2 AF860/200kHz/TC2024 0 to 4 m/s Wuhle 1998 30 m river 2 AF860/200kHz/TC2024 0 to 4 m/s Rummelsburger Bucht 2000 20 m river 4 AF860/200kHz/TC2024 -1 to 1 m/s Wuhle II 2000 30 m river 2 AF860/200kHz/TC2024 0 to 4 m/s Allendebrücke 2004 40 m river 2 R2-2000/28KHZ/TC2115 -10 to 10 m/s Schmöckwitz 2004 20 m river 2 AFC8-40/200KHZ/TC2153 -10 to 10 m/s
Staatlisces Umwelta. Itzehoe Moisling/Trave 2002 30 m river 2 AF860/200kHz/TC2024 -0,5 to 3 m/s
Stadt Köln Köln 2000 3,7 m Sewage canal 2 AF810/200kHz/TC2024 0 to 3 m/s Köln 2000 3,1 m Sewage canal 2 AF810/200kHz/TC2024 0 to 3 m/s Köln 2000 2,8 m Sewage canal 2 AF810/200kHz/TC2024 0 to 3 m/s Köln 2000 3,0 m Sewage canal 2 AF810/200kHz/TC2024 0 to 3 m/s
Stadtwerke München Moosburg 1998 30 m canal 1 AF860/200kHz/TC2024 0 to 4 m/s
StAUN Lippstadt Schwerte/Ruhr 1997 30 m river 2 AF860/200kHz/TC2024 0 to 4 m/s
StAUN Lübz Bolter Kanal 1996 8 m river 1 AF810/200kHz/TC2111 -1 to 3 m/s
StAUN Neubrandenburg Altentreptow/Randkanal 1996 15 m canal 2 AF860/200kHz/TC2024 0 to 3 m/s Altentreptow/Tollense 1996 15 m river 2 AF860/200kHz/TC2024 0 to 3 m/s
Quantum Hydrometrie GmbH Gesellschaft für Meß- und Systemtechnik GmbH Zossener Straße 55, D-10961 Berlin, Germany Tel:+49 (0)30 698 110-0 E-mail: [email protected] Fax:+49 (0)30 698 110-99 Internet: www.quantum-hydrometrie.de CLIENT YEAR WIDTH TYPE PATHS SYSTEM/FREQUENCY/TRANSD...R. RANGE
Neubrandenburg/Tollense 1996 15 m river 2 AF860/200kHz/TC2024 0 to 3 m/s Klempenow/Tollense 2000 25 m river 4 AF860/200kHz/TC2024 0 to 3 m/s Schleuse Zwensow 2000 10 m canal 2 AF860/200kHz/TC2024 0 to 3 m/s Brohm-Oberpegel 2001 3,3 m river 2 AFC860/200kHz/TC2153 0 to 1,5 m/s
StAUN Rostock Bützow/Warnow 1998 15 m river 2 AF860/200kHz/TC2024 0 to 3 m/s Rostock/Warnow 1999 20 m river 2 AF860/200kHz/TC2024 0 to 3 m/s Wolken/Nebel 2000 20 m river 2 AF860/200kHz/TC2024 0 to 3 m/s Tessin 2002 12 m river 2 AFC860/200kHz/TC2153 0 to 4 m/s Schwaan 2003 12 m river 2 AFC8-40/200kHz/TC2153 -10 to 10 m/s
StAUN Ueckermünde Anklam/Peene 1995 50 m river 2 AF81000/33kHz/TC2084 -1 to 3 m/s Grambin/Zarow 1996 20 m river 2 AF860/200kHz/TC2024 -1 to 3 m/s Ueckermünde/Uecker 1997 15 m river 4 AF860/200kHz/TC2024 -1 to 3 m/s Pasewalk 2004 12 m river 2 AF8-40/200KHZ/TC2153 -10 to 10 m/s
StAUN Schwerin Garlitz 2005 12 m river 2 AFC8-40/200KHZ/TC2153 -10 to 10 m/s
StAWA Mainz Oberingelheim/Selz 1999 4 m river 3 AF860/200kHz/TC2024 0 to 2 m/s
StAWA Aurich Nortmoor/Jümme 1995 45 m river 1 AF81000/33kHz/TC2084 -3 to 3 m/s Leer/Leda 1997 50 m river 1 AF81000/33kHz/TC2084 -3 to 3 m/s
Strom und Hafen Norderelbe 1997 220 m river 2 AF82000/28kHz/TC2115 -3 to 4 m/s Süderelbe 1997 235 m river 2 AF82000/28kHz/TC2115 -3 to 4 m/s Teufelsbrück 1997 500 m river 2 AF82000/28kHz/TC2115 -3 to 4 m/s
StUA Herten Haltern/Lippe 1999 35 m river 8 AF860/200kHz/TC2024 0 to 4 m/s
StUA Krefeld Neubrück/Erft 1998 25 m river 2 AF860/200kHz/TC2024 0 to 4 m/s
StUA Kiel Schwentine 2002 20 m river 2 AFC 860/200kHz/TC2153 -1 to 4 m/s
StUA Schleswig Bongsieler Kanal 1998 6,5 m canal 2 AF860/200kHz/TC2024 0 to 2 m/s Arlau 1999 4,5 m canal 2 AF860/200kHz/TC2024 0 to 2 m/s
Quantum Hydrometrie GmbH Gesellschaft für Meß- und Systemtechnik GmbH Zossener Straße 55, D-10961 Berlin, Germany Tel:+49 (0)30 698 110-0 E-mail: [email protected] Fax:+49 (0)30 698 110-99 Internet: www.quantum-hydrometrie.de CLIENT YEAR WIDTH TYPE PATHS SYSTEM/FREQUENCY/TRANSD...R. RANGE
Mobile Anlagee 2002 1 -60 m 2 AFC 860/200kHz/TC2024 -4 to 4 m/s Füsing 2003 14 m river 2 AFC 8-100/200kHz/TC-2153 -10 to 10 m/s Soholm 2004 12 m river 4 AFC 8-40/200kHz/TC2153 -10 to 10 m/s Tönning 2004 6 m river 1 AFC 8-40/200kHz/TC2153 -10 bis 10 m/s Leck 2004 10 m river 4 AFC 8-40/200kHz/TC 2153 -10 to 10 m/s Jägerkrug 2004 12 m river 2 AFC8-40/200KHZ/TC2153 -10 to 10 m/s
StUA Lippstadt Villigst 2003 46 m river 4 AFC 860/200kHz/TC2024 -10 to 10 m/s Kesseler 2003 117 m river 4 AFC 860/200kHz/TC2153 -10 to 10 m/s Meschede 2004 30 m river 2 AFC860/200KHZ/TC2153 -10 to 10 m/s Bredelar 2005 10 m river 2 AFC8-40/200KHZ/TC2153 -10 to 10 m/s Belecke 2004 10 m river 2 AFC8-40/200KHZ/TC2153 -10 to 10 m/s Cappel 2005 10 m river 3 AFC8-40/200KHZ/TC2153 -10 to 10 m/s
Volkswagen Wolfsburg 2000 20 m Concrete channal 2 AF860/200kHz/TC2024 0 to 4 m/s
Wasserbauamt Pfarrkirchen 2001 10 m river 5 AF860/200kHz/TC 2024 0 to 15 m/s
Wasserverband Rems Schorndorf 2002 20 m river 4 AF860/200kHz/TC 2153 0 to 2 m/s Winterbach 2002 15 m river 2 AF860/200kHz/TC 2153 0 to 2 m/s
Wasserwirtschaftsamt Kempten Grüntensee 1999 2,20 m tunnel 2 AF810/200kHz/TC2024 0 to 6 m/s Grüntensee 1999 3,50 m pipe 1 AF810/200kHz/TC2024 0 to 6 m/s GRüntensee 2001 2,60 m tunnel 1 AFC860/200kHz/TC2024 0 to 6 m/s
WSA Brandenburg Kade 1995 40 m waterway 2 AF81000/33kHz/TC2084 -1 to 3 m/s Havelberg 1996 60 m river 2 AF81000/33kHz/TC2084 0 to 4 m/s Ketzin 1997 80 m waterway 2 AF82000/28kHz/TC2115 -1 to 3 m/s Detershagen 1999 50 m waterway 4 AF860/200kHz/TC2024 0 to 3 m/s Tieckow 2000 50 m waterway 4 AF860/200kHz/TC2024 0 to 3 m/s
WSA Hann.-Münden Rotenburg/Fulda 1998 45 m river 6 AF860/200kHz/TC2024 0 to 3 m/s Schmittlotheim/Eder 1998 40 m river 4 AF860/200kHz/TC2024 0 to 4 m/s
WSA Heidelberg Rockenau/Neckar 1999 70 m river 2 AF82000/28kHz/TC2115 0 to 4 m/s
WSA Koblenz Alken 2002 210 river 2 R 22000/28kHz/TC2115 0 to 4 m/s
Quantum Hydrometrie GmbH Gesellschaft für Meß- und Systemtechnik GmbH Zossener Straße 55, D-10961 Berlin, Germany Tel:+49 (0)30 698 110-0 E-mail: [email protected] Fax:+49 (0)30 698 110-99 Internet: www.quantum-hydrometrie.de CLIENT YEAR WIDTH TYPE PATHS SYSTEM/FREQUENCY/TRANSD...R. RANGE
Wupperverband Beyenburg/Wupper 1999 35 m river 2 AF860/200kHz/TC2024 0 to 3 m/s Laaken/Wupper 1999 30 m river 2 AF860/200kHz/TC2024 0 to 3 m/s Rutenbeck/Wupper 1999 40 m river 2 AF860/200kHz/TC2024 0 to 3 m/s Große Dhünn Talsperre/Dhünn 2000 20 m river 3 AF860/200kHz/TC2024 0 to 3 m/s Krebsöge/Wupper 2000 30 m river 3 AF860/200kHz/TC2024 0 to 3 m/s Bever-Talsperre 2002 30 m canal 3 AF860/200kHz/TC2111 0 to 2 m/s Kabelbrücke Wuppertal 2004 10 m river 2 AFC8-40/200kHz/TC2024 -10 to 10 m/s
GREECE
ΕΕΥΥΥ∆∆∆ΑΑΑΠΠ Mornos/Amfissa 1999 6 m canal 1 AF860/200kHz/TC2024 0 to 5 m/s
ITALYTALY
CNR Perugia/Teverre 1999 50 m river 2 AF82000/28kHz/TC2115 0 to 4 m/s
SEBA Hydrometrie Rom 2002 105 river 3 AF 82000/28kHz/TC2115 0 to 4 m/s
Consorzio Venezia Nuova Malamocco 1998 450 m river 2 AF82000/28kHz/TC2115 -3 to +3 m/s Iesolo 2000 10 m canal 1 AF860/200kHz/TC2024 -2 to +2 m/s Fiume Vallio 2000 25 m river 2 AF860/200kHz/TC2024 -2 to s +2 m/s Canale Osellino (Tessera) 2000 30 m river 2 AF860/200kHz/TC2024 -2 to +2 m/s Scaricatore alle Rotte 2000 20 m river 2 AF860/200kHz/TC2024 -2 to +2 m/s Marghera 2000 20 m canal 2 AF860/200kHz/TC2024 -2 to +2 m/s Malcontenta (Ca Cosma) 2000 15 m canal 1 AF860/200kHz/TC2024 -2 to +2 m/s Lugo 2000 8 m river 1 AF860/200kHz/TC2024 -2 to +2 m/s Canaletta di Lugo 2000 14 m canal 4 AF860/200kHz/TC2024 -2 to +2 m/s Canale di Lova 2000 8 m river 1 AF860/200kHz/TC2024 -2 to +2 m/s Canale Gavaizza 2000 12 m river 2 AF860/200kHz/TC2024 -2 to +2 m/s Canale Novissimo 2000 20 m river 1 AF860/200kHz/TC2024 -2 to +2 m/s Fiume Montalbano 2000 25 m river 2 AF860/200kHz/TC2024 -2 to +2 m/s Brenta 2000 45 m river 2 AF860/200kHz/TC2024 -2 to +2 m/s St. Nicolo 2001 350 m river 2 AF82000/28kHz/TC2115 -3 to +3 m/s Treporti 2001 400 m river 2 AF82000/28kHz/TC2115 -3 to +3 m/s Chioggia 2001 300 m river 2 AF82000/28kHz/TC2115 -3 to +3 m/s Erasmo 2002 60 m river 2 AF 860/200kHz/TC2024 -4 to 4 m/s
Quantum Hydrometrie GmbH Gesellschaft für Meß- und Systemtechnik GmbH Zossener Straße 55, D-10961 Berlin, Germany Tel:+49 (0)30 698 110-0 E-mail: [email protected] Fax:+49 (0)30 698 110-99 Internet: www.quantum-hydrometrie.de CLIENT YEAR WIDTH TYPE PATHS SYSTEM/FREQUENCY/TRANSD...R. RANGE
Etschwerke Bozen 1999 4 m Stollen 4 AF860/200kHz/TC2024 0 to 4 m/s Fossa D´Argine 2001 5 m canal 1 AF860/200kHz/TC2024 0 to 3 m/s Cá Solaro 2001 5 m canal 1 AF860/200kHz/TC2024 0 to 3 m/s
JAAPANPAN
Biwa Lake 2001 60 m river 2 AF82000/28kHz/TC2115 0 to 3 m/s
SWITZERLAND
Bundesamt für Umwelt Basel/Rhein 1996 250 m river 2 AF81000/33kHz/TC2084 0 to 4 m/s
SPAIN
U.T.E. Jucar Huerto Mulet/Rio Jucar 1999 45 m river 1 AF860/200kHz/TC2024 0 to 4 m/s Rio Ebro 2002 12 m river 1 AF8200/28kHz/TC2115 0 to 1,2 m/s
ADASA Sistemas Acueducto del Rucas 2001 4 m canal 2 AF860/200kHz/TC2024 0 to 3 m/s Canal Tipo 2001 4 m canal 2 AF860/200kHz/TC2024 0 to 3 m/s Rio Zujar 2001 50 m river 2 AF82000/28kHz/TC2084 0 to 4 m/s
Iberdrola Rio Tajo 2001 70 m river 2 AF82000/28kHz/TC2084 0 to 4 m/s Helin 2000 28 m canal 1 AF860/200kHz/TC2024 0 to 3 m/s
SOUTH AFRICAAFRICA
Lesotho Mohale 2003 7,2 m tunnel 2 AFC 830/200kHz/TC2153 -10 to 10 m/s Matsoku 2003 4,5 m tunnel 3 AFC 830/200kHz/TC2153 -10 to 10 m/s
TUNESIAUNESIA
Projkt GTZ 2002 4,5 m canal 1 AF860/200kHz/TC2153 0 to 2 m/s
Quantum Hydrometrie GmbH Gesellschaft für Meß- und Systemtechnik GmbH Zossener Straße 55, D-10961 Berlin, Germany Tel:+49 (0)30 698 110-0 E-mail: [email protected] Fax:+49 (0)30 698 110-99 Internet: www.quantum-hydrometrie.de Quantum Hydrometrie GmbH Gesellschaft für Meß- und Systemtechnik GmbH Zossener Straße 55, D-10961 Berlin, Germany Tel:+49 (0)30 698 110-0 E-mail: [email protected] Fax:+49 (0)30 698 110-99 Internet: www.quantum-hydrometrie.de