New Explicit Correlation for the Compressibility Factor of Natural Gas: Linearized Z-Factor Isotherms

Total Page:16

File Type:pdf, Size:1020Kb

New Explicit Correlation for the Compressibility Factor of Natural Gas: Linearized Z-Factor Isotherms J Petrol Explor Prod Technol (2016) 6:481–492 DOI 10.1007/s13202-015-0209-3 ORIGINAL PAPER - PRODUCTION ENGINEERING New explicit correlation for the compressibility factor of natural gas: linearized z-factor isotherms 1 2 3 Lateef A. Kareem • Tajudeen M. Iwalewa • Muhammad Al-Marhoun Received: 14 October 2014 / Accepted: 17 October 2015 / Published online: 18 December 2015 Ó The Author(s) 2015. This article is published with open access at Springerlink.com Abstract The compressibility factor (z-factor) of gases is Keywords Z-factor Á Explicit correlation Á Reduced a thermodynamic property used to account for the devia- temperature Á Reduced pressure Á Natural gas tion of real gas behavior from that of an ideal gas. Corre- lations based on the equation of state are often implicit, List of symbols because they require iteration and are computationally P Pressure (psi) expensive. A number of explicit correlations have been P Pseudo-critical pressure derived to enhance simplicity; however, no single explicit pc P Pseudo-reduced pressure correlation has been developed for the full range of pseudo- pr ÀÁ T Temperature (R) reduced temperatures 1:05 Tpr 3 and pseudo-reduced ÀÁ Tpc Pseudo-critical temperature (R) pressures 0:2 Ppr 15 , which represents a significant Tpr Pseudo-reduced temperature research gap. This work presents a new z-factor correlation Ppc Pseudo-critical pressure (psi) that can be expressed in linear form. On the basis of Hall Ppr Pseudo-reduced pressure and Yarborough’s implicit correlation, we developed the v Initial guess for iteration process new correlation from 5346 experimental data points Y Pseudo-reduced density extracted from 5940 data points published in the SPE z-factor Compressibility factor natural gas reservoir engineering textbook and created a linear z-factor chart for a full range of pseudo-reduced temperatures ð1:15 Tpr 3Þ and pseudo-reduced pres- sures ð0:2 Ppr 15Þ. Introduction The compressibility factor (z-factor) of gases is used to correct the volume of gas estimated from the ideal gas equation to the actual value. It is required in all calculations & Lateef A. Kareem involving natural gases. [email protected] The z-factor is the ratio of the volume occupied by a Tajudeen M. Iwalewa given amount of a gas to the volume occupied by the same [email protected] amount of an ideal gas: Muhammad Al-Marhoun Vactual [email protected] z ¼ ð1Þ Videal 1 Center for Petroleum and Minerals, King Fahd University of Substituting for Videal in the ideal gas equation Petroleum and Minerals, Dhahran, Saudi Arabia PVactual ¼ znRT ð2Þ 2 Department of Earth Sciences, University of Cambridge, Cambridge CB2 3EQ, UK For generalization, the z-factor is expressed as a 3 Reservoir Technologies (ResTec), Dammam, Saudi Arabia function of pseudo-reduced temperature and pressure 123 482 J Petrol Explor Prod Technol (2016) 6:481–492 (Trube 1957; Dranchuk et al. 1971; Abou-kassem and Implicit z-factor correlations Dranchuk 1975; Sutton 1985; Heidaryan et al. 2010). Dranchuk et al. (1971) defined pseudo-reduced tem- The three most popular correlations for calculating the perature and pressure as the ratio of temperature and z-factor are implicit. The three correlations, described in pressure to the pseudo-critical temperature and pressure of the following subsections, are well known for their accu- natural gas, respectively: racies, almost unit correlation of regression coefficients and T P low maximum errors. Tpr ¼ ; Ppr ¼ ð3Þ Tpc Ppc Hall and Yarborough’s correlation (Trube 1957) The pseudo-critical properties of gas are the molar abundance (mole fraction weighted) mean of the critical Hall and Yarborough’s correlation is a modification of the properties of the constituents of the natural gas: hard sphere Carnahan–Starling equation of state, with Xn Xn constants developed through regression, and 1500 data Tpc ¼ yiTci; Ppc ¼ yiPci ð4Þ points extracted from Standing and Katz’s original z-factor i¼1 i¼1 chart, as shown in Fig. 2. As a function of specific gravity (air = 1.0), Sutton A P z ¼ 1 pr ; ð7Þ (1985) provides y 2 Tpc ¼ 169:2 þ 349:5cg À 74:0cg ð5Þ where y is the root of the following equation: 2 y þ y2 þ y3 À y4 Ppc ¼ 756:8 À 131:07cg À 3:6cg ð6Þ 2 A4 À A1Ppr þ À A2y þ A3y ¼ 0 ð1 À yÞ3 A plot of 5346 data points covering a full range of À1:2ð1ÀtÞ2 2 3 A1 ¼ 0:06125te ; A2 ¼ 14:76t À 9:76t þ 4:58t ; pseudo-reduced temperatures ð1:15 Tpr 3Þ and pseudo- 2 3 1 reduced pressures ð0:2 Ppr 15Þ is shown in Fig. 1 A3 ¼ 90:7t À 242:2t þ 42:4t ; A4 ¼ 2:18 þ 2:82t; t ¼ Tpr Fig. 1 Plot of experimental measurements of the z-factor 123 J Petrol Explor Prod Technol (2016) 6:481–492 483 Fig. 2 Standing and Katz’s compressibility factor chart hi Dranchuk and Abou-Kassem’s correlation (Abou-kassem 2 R2 R y2ð1 þ A y2ÞeðÀA11y Þ þ R y À þ R y2 À R y5 þ 1 ¼ 0 and Dranchuk 1975) 5 11 1 y 3 4 A A A A 0:27P R ¼ A þ 2 þ 3 þ 4 þ 5 ; R ¼ pr 1 1 T T3 T4 T5 2 T This is an eleven-constant modification of the Benedict– pr pr pr pr !pr Webb–Rubin equation of state. The constants were calcu- A7 A8 A7 A8 A10 R3 ¼ A6 þ þ 2 ; R4 ¼ A9 þ 2 ; R5 ¼ 3 lated using a regression method, with 1500 data points Tpr Tpr Tpr Tpr Tpr extracted from standing and Katz’s chart. A1 ¼ 0:3265; A2 ¼À1:0700; A3 ¼À0:5339; A4 ¼ 0:01569; 0:27P z ¼ pr ; ð8Þ A5 ¼À0:05165; A6 ¼ 0:5475; A7 ¼ 0:7361; A8 ¼ 0:1844; yTpr A9 ¼ 0:1056; A10 ¼ 0:6134; A11 ¼ 0:7210 where y is the root of the following equation: 123 484 J Petrol Explor Prod Technol (2016) 6:481–492 Dranchuk, Purvis and Robinson’s Correlation (Dranchuk Table 1 Constants of Heidaryan et al.’s correlation et al. 1971) Constants for Ppr 3 Constants for Ppr [ 3 This is a further modification of the earlier obtained DAK A1 2.827793 3.252838 -1 -1 correlation. The DPR has eight constants and requires less A2 -4.688191 9 10 -1.306424 9 10 -1 computational workload to obtain the z-factor. A3 -1.262288 6.449194 9 10 0:27P A4 -1.536524 -1.518028 z ¼ pr ; ð9Þ A5 -4.535045 -5.391019 yTpr -2 -2 A6 6.895104 9 10 -1.379588 9 10 -1 -2 where y is the root of the following equation: A7 1.903869 9 10 6.600633 9 10 hi -1 -1 2 T A8 6.200089 9 10 6.120783 9 10 2 2 ðÀA8y Þ 2 5 5 T4y ð1 þ A8y Þe þ 1 þ T1y þ T2y þ T3y þ ¼ 0 y A9 1.838479 2.317431 -1 -1 A2 A3 A5 A5A6 A10 4.052367 9 10 1.632223 9 10 T1 ¼ A1 þ þ 3 ; T2 ¼ A4 þ ; T3 ¼ ; -1 Tpr Tpr Tpr Tpr A11 1.073574 5.660595 9 10 A7 0:27Ppr T4 ¼ 3 ; T5 ¼ Tpr Tpr A1 ¼ 0:31506237; A2 ¼À1:04670990; Heidaryan, Moghdasi and Rahimi’s Correlation A3 ¼À0:57832720; A4 ¼ 0:53530771; A5 ¼À0:61232032; A6 ¼À0:10488813; Heidaryan et al. (2010) developed a new explicit A7 ¼ 0:68157001; A8 ¼ 0:68446549 piecewise correlation using regression analysis of the z-factor experimental value for reduced pseudo-pres- These correlations are effective; however, they do not sure of fewer and [3(Table1). The correlation has a converge (or converge on wrong pseudo-reduced density total of 22 constants, with a discontinuity at Ppr ¼ 3 values) when the temperature of the systems is close to the (Fig. 2) and correlation regression coefficient of critical temperature. In addition, they are computationally 0.99,963. expensive. It is these limitations that necessitated the 0 ÀÁ 1 A5 2 A9 A11 A1 þ A3 lnðPprÞþ þ A7 lnðPprÞ þ 2 þ lnðPprÞ development of the current explicit correlations. Tpr T Tpr z ¼ ln@ ÀÁpr A A4 2 A8 A10 1 þ A lnðPprÞþ þ A lnðPprÞ þ 2 þ lnðPprÞ 2 Tpr 6 T Tpr Explicit correlations pr ð11Þ Explicit correlations do not require an iterative procedure. For some petroleum engineering applications, it is Therefore, they do not have the problem of convergence as often necessary to compute the derivative of z-factor opposed to implicit correlations. One of the best explicit with respect to pressure or temperature. A function that correlations for evaluation of the z-factor was given by is discontinuous at a certain point is not differentiable at Beggs and Brills (1973). More recent ones are Heidaryan that point (O’Neil 2012). Therefore, the explicit et al. (2010), Azizi et al. (2010) and Sanjari and Lay (2012) correlation developed by Heidaryan et al. (2010) correlations. A short description of some of the explicit cannot be used to evaluate the derivative of the z- correlations is presented in the following subsections. factor with respect to the pseudo-reduced pressure at Ppr ¼ 3(Fig.3). Brill and Beggs’ compressibility factor (1973) 1 À A Azizi, Behbahani and Isazadeh’s Correlation z ¼ A þ þ CpD ; eB pr Azizi et al. (2010) presented an explicit correlation with 20 where constants for a reduced temperature range of 1:1 Tpr 2 0:5 A ¼ 1:39ðTpr À 0:92Þ À 0:36Tpr À 0:10; and reduced pressure range of 0:2 Ppr 11.
Recommended publications
  • Carbon Dioxide Heat Transfer Coefficients and Pressure
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Archivio della ricerca - Università degli studi di Napoli Federico II international journal of refrigeration 33 (2010) 1068e1085 available at www.sciencedirect.com www.iifiir.org journal homepage: www.elsevier.com/locate/ijrefrig Carbon dioxide heat transfer coefficients and pressure drops during flow boiling: Assessment of predictive methods R. Mastrullo a, A.W. Mauro a, A. Rosato a,*, G.P. Vanoli b a D.E.TE.C., Facolta` di Ingegneria, Universita` degli Studi di Napoli Federico II, p.le Tecchio 80, 80125 Napoli, Italy b Dipartimento di Ingegneria, Universita` degli Studi del Sannio, corso Garibaldi 107, Palazzo dell’Aquila Bosco Lucarelli, 82100 Benevento, Italy article info abstract Article history: Among the alternatives to the HCFCs and HFCs, carbon dioxide emerged as one of the most Received 13 December 2009 promising environmentally friendly refrigerants. In past years many works were carried Received in revised form out about CO2 flow boiling and very different two-phase flow characteristics from 8 February 2010 conventional fluids were found. Accepted 5 April 2010 In order to assess the best predictive methods for the evaluation of CO2 heat transfer Available online 9 April 2010 coefficients and pressure gradients in macro-channels, in the current article a literature survey of works and a collection of the results of statistical comparisons available in Keywords: literature are furnished. Heat exchanger In addition the experimental data from University of Naples are used to run a deeper Boiling analysis. Both a statistical and a direct comparison against some of the most quoted Carbon dioxide-review predictive methods are carried out.
    [Show full text]
  • New Explicit Correlation for the Compressibility Factor of Natural Gas: Linearized Z-Factor Isotherms
    J Petrol Explor Prod Technol DOI 10.1007/s13202-015-0209-3 ORIGINAL PAPER - PRODUCTION ENGINEERING New explicit correlation for the compressibility factor of natural gas: linearized z-factor isotherms 1 2 3 Lateef A. Kareem • Tajudeen M. Iwalewa • Muhammad Al-Marhoun Received: 14 October 2014 / Accepted: 17 October 2015 Ó The Author(s) 2015. This article is published with open access at Springerlink.com Abstract The compressibility factor (z-factor) of gases is Keywords Z-factor Á Explicit correlation Á Reduced a thermodynamic property used to account for the devia- temperature Á Reduced pressure Á Natural gas tion of real gas behavior from that of an ideal gas. Corre- lations based on the equation of state are often implicit, List of symbols because they require iteration and are computationally P Pressure (psi) expensive. A number of explicit correlations have been P Pseudo-critical pressure derived to enhance simplicity; however, no single explicit pc P Pseudo-reduced pressure correlation has been developed for the full range of pseudo- pr ÀÁ T Temperature (R) reduced temperatures 1:05 Tpr 3 and pseudo-reduced ÀÁ Tpc Pseudo-critical temperature (R) pressures 0:2 Ppr 15 , which represents a significant Tpr Pseudo-reduced temperature research gap. This work presents a new z-factor correlation Ppc Pseudo-critical pressure (psi) that can be expressed in linear form. On the basis of Hall Ppr Pseudo-reduced pressure and Yarborough’s implicit correlation, we developed the v Initial guess for iteration process new correlation from 5346 experimental data points Y Pseudo-reduced density extracted from 5940 data points published in the SPE z-factor Compressibility factor natural gas reservoir engineering textbook and created a linear z-factor chart for a full range of pseudo-reduced temperatures ð1:15 Tpr 3Þ and pseudo-reduced pres- sures ð0:2 Ppr 15Þ.
    [Show full text]
  • Technical Brief
    Journal of Energy Resources Technology Technical Brief Formulations for the Thermodynamic on mathematical integration of the correlations developed for spe- cific heat, and the property estimates obtained are remarkably Properties of Pure Substances accurate. The fundamental equation-of-state formulation typically re- quires several numerical constants to ensure accuracy. Besides, George A. Adebiyi subsequent determination of the complete list of thermodynamic Mechanical Engineering Department, Mississippi State properties from the fundamental equation of state requires obtain- University, Mississippi State, MS 39762 ing differentials of the characteristic function. The functional rep- e-mail: [email protected] resentation must be accurate, and great precision will be required if the estimates obtained for these other thermodynamic properties are to be reliable. These formulations are, as a result, not suitable for incorporation into programs that require repeated computation This article presents a procedure for formulation for the thermo- of system properties. dynamic properties of pure substances using two primary sets of The integrated approach is described in general terms in this data, namely, the pvT data and the specific heat data, such as the article. An illustration is provided using dry air at pressures as constant-pressure specific heat c p as a function of pressure and high as 50 bar ͑725 psia͒ and temperatures in the range 250 K temperature. The method makes use of a linkage, on the basis of ͑450 R͒ to 1000 K ͑1800 R͒. the laws of thermodynamics, between the virial coefficients for the pvT data correlation and those for the corresponding specific heat data correlation for the substance.
    [Show full text]
  • Real Gases – As Opposed to a Perfect Or Ideal Gas – Exhibit Properties That Cannot Be Explained Entirely Using the Ideal Gas Law
    Basic principle II Second class Dr. Arkan Jasim Hadi 1. Real gas Real gases – as opposed to a perfect or ideal gas – exhibit properties that cannot be explained entirely using the ideal gas law. To understand the behavior of real gases, the following must be taken into account: compressibility effects; variable specific heat capacity; van der Waals forces; non-equilibrium thermodynamic effects; Issues with molecular dissociation and elementary reactions with variable composition. Critical state and Reduced conditions Critical point: The point at highest temp. (Tc) and Pressure (Pc) at which a pure chemical species can exist in vapour/liquid equilibrium. The point critical is the point at which the liquid and vapour phases are not distinguishable; because of the liquid and vapour having same properties. Reduced properties of a fluid are a set of state variables normalized by the fluid's state properties at its critical point. These dimensionless thermodynamic coordinates, taken together with a substance's compressibility factor, provide the basis for the simplest form of the theorem of corresponding states The reduced pressure is defined as its actual pressure divided by its critical pressure : The reduced temperature of a fluid is its actual temperature, divided by its critical temperature: The reduced specific volume ") of a fluid is computed from the ideal gas law at the substance's critical pressure and temperature: This property is useful when the specific volume and either temperature or pressure are known, in which case the missing third property can be computed directly. 1 Basic principle II Second class Dr. Arkan Jasim Hadi In Kay's method, pseudocritical values for mixtures of gases are calculated on the assumption that each component in the mixture contributes to the pseudocritical value in the same proportion as the mol fraction of that component in the gas.
    [Show full text]
  • A Comparison Op Existing Enthalpy Correlations For
    A COMPARISON OP EXISTING ENTHALPY CORRELATIONS FOR PETROLEUM FRACTIONS By Roberta Fleckenstein ProQuest Number: 10782088 All rights reserved INFORMATION TO ALL USERS The quality of this reproduction is dependent upon the quality of the copy submitted. In the unlikely event that the author did not send a com plete manuscript and there are missing pages, these will be noted. Also, if material had to be removed, a note will indicate the deletion. uest ProQuest 10782088 Published by ProQuest LLC(2018). Copyright of the Dissertation is held by the Author. All rights reserved. This work is protected against unauthorized copying under Title 17, United States C ode Microform Edition © ProQuest LLC. ProQuest LLC. 789 East Eisenhower Parkway P.O. Box 1346 Ann Arbor, Ml 48106- 1346 T-1913 A thesis submitted to the Faculty and the Board of Trustees of the Colorado School of Mines in partial ful­ fillment of the requirements for the degree of Master of Science. Signed • Roberta R7 Fleckenstein Golden, Colorado Date: ' "//-I- , 1976 Approved A . J , I ^ d n a y The s i s/Ad vi s or V. F. ucesavage Thesis Advisor Head of Department Golden, Colorado Date :/2j / j______ , 1975 11 T-1913 ABSTRACT A study is made of existing enthalpy correlations for petroleum fractions in the hope that these correlations can be applied to coal-derived liquids# No one correlation is assessed to be the best for petroleum fractions as the area of enthalpy prediction for naturally occurring crudes is constantly being improved. A section containing sample calculations and the
    [Show full text]
  • Equation of State - Wikipedia, the Free Encyclopedia 頁 1 / 8
    Equation of state - Wikipedia, the free encyclopedia 頁 1 / 8 Equation of state From Wikipedia, the free encyclopedia In physics and thermodynamics, an equation of state is a relation between state variables.[1] More specifically, an equation of state is a thermodynamic equation describing the state of matter under a given set of physical conditions. It is a constitutive equation which provides a mathematical relationship between two or more state functions associated with the matter, such as its temperature, pressure, volume, or internal energy. Equations of state are useful in describing the properties of fluids, mixtures of fluids, solids, and even the interior of stars. Thermodynamics Contents ■ 1 Overview ■ 2Historical ■ 2.1 Boyle's law (1662) ■ 2.2 Charles's law or Law of Charles and Gay-Lussac (1787) Branches ■ 2.3 Dalton's law of partial pressures (1801) ■ 2.4 The ideal gas law (1834) Classical · Statistical · Chemical ■ 2.5 Van der Waals equation of state (1873) Equilibrium / Non-equilibrium ■ 3 Major equations of state Thermofluids ■ 3.1 Classical ideal gas law Laws ■ 4 Cubic equations of state Zeroth · First · Second · Third ■ 4.1 Van der Waals equation of state ■ 4.2 Redlich–Kwong equation of state Systems ■ 4.3 Soave modification of Redlich-Kwong State: ■ 4.4 Peng–Robinson equation of state Equation of state ■ 4.5 Peng-Robinson-Stryjek-Vera equations of state Ideal gas · Real gas ■ 4.5.1 PRSV1 Phase of matter · Equilibrium ■ 4.5.2 PRSV2 Control volume · Instruments ■ 4.6 Elliott, Suresh, Donohue equation of state Processes:
    [Show full text]
  • Prediction of Natural Gas Compressibility Factor in a Single-Phase Gas Reservoir: a Comparative Study
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Arid Zone Journal of Engineering, Technology and Environment (AZOJETE) ARID ZONE JOURNAL OF ENGINEERING, TECHNOLOGY & ENVIRONMENT AZOJETE March 2020. Vol. 16(1):164-178 Published by the Faculty of Engineering, University of Maiduguri, Maiduguri, Nigeria. Print ISSN: 1596-2490, Electronic ISSN: 2545-5818 www.azojete.com.ng ORIGINAL RESEARCH ARTICLE PREDICTION OF NATURAL GAS COMPRESSIBILITY FACTOR IN A SINGLE-PHASE GAS RESERVOIR: A COMPARATIVE STUDY M. N. Bello* and M. A. Musa (Department of Chemical Engineering, University of Maiduguri, Maiduguri, Borno State, Nigeria) *Corresponding author’s email address: [email protected] ARTICLE INFORMATION ABSTRACT Submitted 19 December, 2019 Natural gas compressibility factor plays important roles in pipeline Revised 13 July, 2019 design, reserve estimation and gas metering. The aim of this study is to presents the most accurate and reliable method of computing gas Accepted 28 July, 2020 compressibility factor in a single-phase gas reservoir at various reservoir pressures. In this study, the gas compositions and the specific gravity of the respective gas compounds were retrieved from literatures. This Keywords: specific gravity determine the pseudo critical and the pseudo reduced compressibility factor properties (temperature and pressure) of the respective gas compounds pseudo-critical temperature being studied. The predicted methods studied are Papay correlation, and pressure Hall-Yarborough equation of state (EOS), viral EOS, Beggs and Brill and pseudo-reduced Dranchuk-Abu-Kassem correlation. The methods are expressed as temperature and pressure functions of the pseudo-reduced temperature and pressure, thereby equation of state predicting the compressibility factor of the predicted methods.
    [Show full text]
  • Generalized COP Estimation of Heat Pump Processes
    Downloaded from orbit.dtu.dk on: Sep 24, 2021 Heat pump COP, part 2: Generalized COP estimation of heat pump processes Jensen, Jonas K.; Ommen, Torben; Reinholdt, Lars; Markussen, Wiebke B.; Elmegaard, Brian Published in: Proceedings of the13th IIR-Gustav Lorentzen Conference on Natural Refrigerants Link to article, DOI: 10.18462/iir.gl.2018.1386 Publication date: 2018 Document Version Peer reviewed version Link back to DTU Orbit Citation (APA): Jensen, J. K., Ommen, T., Reinholdt, L., Markussen, W. B., & Elmegaard, B. (2018). Heat pump COP, part 2: Generalized COP estimation of heat pump processes. In Proceedings of the13th IIR-Gustav Lorentzen Conference on Natural Refrigerants (Vol. 2, pp. 1136-1145). International Institute of Refrigeration. https://doi.org/10.18462/iir.gl.2018.1386 General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim. DOI: 10.18462/iir.gl.2018.1386 Heat pump COP, part 2: Generalized COP estimation of heat pump processes Jonas K.
    [Show full text]
  • Thermal Properties of Water
    Forschungszentrum Karlsruhe Technik und Umwelt issenscnatiiK FZKA 5588 Thermal Properties of Water K. Thurnay Institut für Neutronenphysik und Reaktortechnik Projekt Nukleare Sicherheitsforschung Juni 1995 Forschungszentrum Karlsruhe Technik und Umwelt Wissenschaftliche Berichte FZKA 5588 Thermal Properties of Water K.Thurnay Institut für Neutronenphysik und Reaktortechnik Projekt Nukleare Sicherheitsforschung Forschungszentrum Karlsruhe GmbH, Karlsruhe 1995 Als Manuskript gedruckt Für diesen Bericht behalten wir uns alle Rechte vor Forschungszentrum Karlsruhe GmbH Postfach 3640, 76021 Karlsruhe ISSN 0947-8620 Abstract The report describes AQUA, a code developed in the Forschungszentrum Karlsruhe to calculate thermal properties of the water in steam explosions. AQUA bases on the H.G.K, water code, yet supplies - besides of the pressure and heat capacity functions - also the thermal conductivity, viscosity and the surface tension. AQUA calculates in a new way the thermal properties in the two phase region, which is more realistic as the one used in the H.G.K, code. AQUA is equipped with new, fast runnig routines to convert temperature-density dependent states into temperature-pressure ones. AQUA has a version to be used on line and versions adapted for batch calculations. A complete description of the code is included. Thermische Eigenschaften des Wassers. Zusammenfassung. Der Bericht befaßt sich mit dem Code AQUA. AQUA wurde im Forschungszentrum Karlsruhe entwickelt um bei der Untersuchung von Dampfexplosionen die thermischen Eigenschaften des Wassers zu liefern. AQUA ist eine Fortentwicklung des H.G.K.-Wassercodes, aber er berechnet - neben Druck- und Wärmeeigenschaften - auch die Wärmeleitfähigket, die Viskosität und die Oberflächenspannung. Im Zweiphasenge• biet beschreibt AQUA die thermischen Eigenschaften mit einer neuen Methode, die real• istischer ist, als das in der H.G.K.-Code dargebotene Verfahren.
    [Show full text]
  • Estimation of Thermodynamic Properties of Petroleum Fractions to Supplement the ASPEN Simulator
    Copyright Warning & Restrictions The copyright law of the United States (Title 17, United States Code) governs the making of photocopies or other reproductions of copyrighted material. Under certain conditions specified in the law, libraries and archives are authorized to furnish a photocopy or other reproduction. One of these specified conditions is that the photocopy or reproduction is not to be “used for any purpose other than private study, scholarship, or research.” If a, user makes a request for, or later uses, a photocopy or reproduction for purposes in excess of “fair use” that user may be liable for copyright infringement, This institution reserves the right to refuse to accept a copying order if, in its judgment, fulfillment of the order would involve violation of copyright law. Please Note: The author retains the copyright while the New Jersey Institute of Technology reserves the right to distribute this thesis or dissertation Printing note: If you do not wish to print this page, then select “Pages from: first page # to: last page #” on the print dialog screen The Van Houten library has removed some of the personal information and all signatures from the approval page and biographical sketches of theses and dissertations in order to protect the identity of NJIT graduates and faculty. Estimation of Thermodynamic Properties of Petroleum Fractions to Supplement the ASPEN Simulator by Steven E. Sund Thesis submitted to the faculty of the Graduate School of the New Jersey Institute of Technology in partial fulfillment of the requirements for the degree of Masters of Science in Chemical Engineering 1989 Copywrite © by Steven E— Sund 1989 APPROVAL SHEET Title of Thesis: Estimation of Thermodynamic Properties of Petroleum Fractions to Supplement the ASPEN Simulator Name of Candidate: Steven E.
    [Show full text]
  • NIST/ASME Steam Properties—STEAM Version 3.0
    NIST Standard Reference Database 10 NIST/ASME Steam Properties—STEAM Version 3.0 User's Guide Allan H. Harvey Eric W. Lemmon Applied Chemicals and Materials Division National Institute of Standards and Technology Boulder, Colorado 80305 June 2013 U.S. Department of Commerce National Institute of Standards and Technology Standard Reference Data Program Gaithersburg, Maryland 20899 The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database. ©2013 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. No part of this database may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the distributor. Certain trade names and other commercial designations are used in this work for the purpose of clarity. In no case does such identification imply endorsement by the National Institute of Standards and Technology, nor does it imply that the products or services so identified are necessarily the best available for the purpose. Microsoft, Windows, Excel, and Visual Basic are either registered trademarks or trademarks of the Microsoft Corporation in the United States and/or other countries; MATLAB is a trademark of MathWorks.
    [Show full text]
  • SBLOCA Analysis of SMART with Trans-Critical CO2 Power Conversion System for Maritime Propulsion
    Transactions of the Korean Nuclear Society Virtual Spring Meeting July 9 -10, 2020 SBLOCA analysis of SMART with Trans-Critical CO2 power conversion system for Maritime Propulsion Bong Seong Oha, Jeong Ik Lee a∗ aKorea Advanced Institute of Science and Technology, Daehak-ro 291, Yuseong-gu, Daejeon, Republic of Korea *Corresponding author: [email protected] 1. Introduction generator and isolated feed water / main steam line, cannot be directly applied to SMART with T-CO2 Northern Sea Route (NSR) located between the system so that the original PRHRS should be replaced Arctic and Russian north coast could save about 40% of with a CO2 based PRHRS (CPRHRS). the sailing distance from Asia (Yokohama) to Europe In this paper, the CPRHRS are designed by (Rotterdam) compared to the conventional route via satisfying NRC requirements and the transient Suez Canal [1] as shown in Fig. 1. performance of the designed system is validated with MARS-KS code. 2. Methods and Results 2.1 CO2 PRHRS design for SMART with T-CO2 cycle Following the NRC recommendations, a new concept of passive residual heat removal system (PRHRS) for SMART is suggested to accomplish hot shutdown condition 200oC within 36 hours and maintain the state Fig. 1. Comparison of Northern Sea Route and for 72 hours [4]. The original SMART is equipped with Conventional Route [2] four trains of water-steam operating PRHRS and it was designed to be capable of accomplishing hot shutdown From these reasons, exploration of the NSR is state with only two trains out of four. Similarly, passive receiving attentions for logistics and resource system of the targeted system is considered as the CO2 development but accessibility of NSR for ordinary natural circulation loop through IHX’s CO2 channels for merchant ships is limited due to difficult ice-condition removing residual heat passively.
    [Show full text]