Photocontrols & Timers

Total Page:16

File Type:pdf, Size:1020Kb

Photocontrols & Timers PMC-CAt-609 PHOTOCONTROLS & TIMERS TO SAVE ENERGY FOR OVER 50 YEARS. PMC-CAT-09-12 Locking Type Photocontrol 12V to 480V Button-Type In Fixture Direct Wire In Photocontrol Photocontrol Pole Mounted Digital Locking Type Push Button Auxillary Power Tap In Wall Timer 6-in-1 Schedules End Sensing Energy Saving Photocontrol /Timer On At Dusk, Off At Your Pre-Set Time Low Voltage Adjustable Photocontrols "Barrel" Type 12 & 24 VAC Photocontrol 24 VDC Easy On/Off Field Setting On Base. Lighting General Purpose Contactor 24 Hour 30 & 60 AMP Time Switch 40 AMP CUSTOMER PHONE SERVICE ALWAYS AVAILABLE 9AM TO 5PM WEEKDAYS EST 201-444-0600 Direct Wire-In Photocontrols (120 - 480 Volts) Heavy-duty Die-cast Enclosure Vandal Proof Lumatrol® “T” Series Lumatrol® “T-30” Wire-In Photo Control - 3000 Watts Cast Aluminum Housing photocontrols - Designed for Designed for those applications which demand more those locations where high vandalism creates high load switching than standard 15 amp. series can maintenance. The heavy-duty cast aluminum housing handle. is 20 times more resistant to high-impact objects (i.e. rocks, bats or small projectiles) than plastic housing. Specifications As the controlling element of the total lighting pack- Housing: Lexan enclosure. age (fixture, lamp ballast) and the least costly compo- Photocell: Broad surface sensing element. nent, it is most important that the control continue to Turn-on: 1 to 3 foot-candles. External light level slide allows function under all adverse conditions. field adjustment between 3 to 10 foot-candles. Specifications Turn-on/ 1:3 Turn-off Ratio: Housing: Vandal proof die cast aluminum housing. Switch Type: Single-pole, single-throw. Contact position at night Photocell: Broad surface sensing element. normally closed. Turn-on: 1 to 3 foot-candles. External light level slide allows Time Delay: Minimum 15 seconds. field adjustment between 3 to 10 foot-candles. Temperature -40˚ to 170˚ F. 1:3 Turn-on/ Range: Turn-off Ratio: Power 1.1 watts average at 120 VAC. Single-pole, single-throw. Contact position at night Switch Type: Consumption: normally closed. Rated Life: 5,000 operations minimum at rated load. Time Delay: Minimum 15 seconds. Threaded Stem: 1/2 inch-14 thread, and fits 1/2 inch knock out. Temperature -40˚ to 170˚ F. Range: Dimensions: 3’’ high, 2’’ wide, 1-3/8’’ deep. Lead Wire: Moisture proof, color coded lead wire. Ordering Guideline Wire length: 6 inches. Model Voltage Rating 1/2 inch-14 thread, and fits 1/2 inch knock out. Threaded Stem: T-30 120 3000 VA Dimensions: 3’’ high, 2’’ wide, 1-3/8’’ deep. T-368 208-277 3000 VA Ordering Guideline T-30DV 105-285 3000 VA Model Voltage Rating T-15-AL 120 1800 VA All Precision photocontrols T-168-AL 208-277 1800 VA are 100% compatible with T-30-AL 120 3000 VA compact fluorescent lamps. T-368-AL 208-277 3000 VA 2 Direct Wire-In Photocontrols (120 - 480 Volts) “ET” A-105 Series “T” “ST” A-105W Series Series U.L. recognized component with standard wall plate Lumatrol® “T”, “ET” & “ST” Series Lumatrol® “A” Series Wire-In Wire-In Photocontrols Photocontrols Specifications Specifications Housing: Weatherproof Lexan® housing. Housing: Durable, high impact Lexan® housing, ultrasonically Photocell: Broad surface sensing element. welded for maximum strength. Nylon locknut provided. Compact in size, A-105 can be mounted directly within a Turn-on: 1 to 3 foot-candles. External light level slide allows field lighting fixture or in lighting standards that are 2 inches adjustment between 3 to 10 foot-candles. in diameter or larger. Turn-on/ 1:3 Photocell: Broad surface sensing element. Turn-off Ratio: Turn-on: 1 to 3 foot-candles. Switch Type: Single-pole, single-throw. Contact position at night 1:3 normally closed. Turn-on/ Turn-off Ratio: Time Delay: Minimum 15 seconds. Switch Type: Single-pole, single-throw. Contact position at night Temperature -40˚ to 158˚F. normally closed. Range: Time Delay: Minimum 15 seconds. Lead Wire: Moisture proof, color coded lead wire. -30˚ to 140˚ F. Wire length: 6 inches. Temperature Range: Threaded Stem: 1/2"-14 thread, and fits 1/2" knock out. Swivel T-Series (ST) is equipped with a swivel mount which allows Lead Wire: Color coded lead wire. Wire length: 15 inches. installer to swivel light sensitive element to the best Threaded 3/8 inch-18 thread; threaded stem 3/4 inches long. position for operation. Stem: Dimensions T Series: 2’’ high, 1-1/2’’ wide, 1’’ deep. Dimensions: 2” high, 1-1/4” wide, 3/4” deep (1-1/2” deep including ST Series: 2’’ high, 1-1/2’’ wide, 1’’ deep (body); 2’’ high, (stem). threaded stem). ET Series: 3½" high, 1" diameter Model Voltage Rating A-105* 120 1000 VA Ordering Guideline A-1068* 208-277 1000 VA Model Voltage Rating A-347† 347 1000 VA ST-15*, T-15* 120 1800 VA A-105W†** 120 1000 VA ST168, T-168 208-277 1800 VA A-1068W** 208-277 1000 VA ST-19**, T-19** 480 1800 VA ** Complete with gasketed metal wall plate (2¾" x 4½"), mounting screws, ST-347** 347 1800 VA and two nylon locknuts so that units will fit any standard outlet box. ET-15 120 1800 VA * UL Recognized & CSA Certified †CSA Certified only. ET-168 208-277 1800 VA Note: The body or housing of all "A" style models must be mounted in a ** Dimensions: 3” high, 2” wide, 1³⁄₈” deep. weather proof enclosure to assure protection from water damage. Only * ETL listed. threaded portion is weather proof. 3 For Direct Wire, Low Voltage Applications LCA SERIES LCS SERIES 24 VDC/VAC 24 VDC/VAC and 12VDC and 12VDC Lumatrol® Low Voltage Lumatrol® Low Voltage “Stem Mount” Photocontrols “Button Type” Photocontrols Specifically designed for a 12 volt DC, or 24 volt AC/DC Specifically designed for inside compatible light fixtures battery operated light source or low voltage control or in weatherproof enclosures 2” in diameter or larger. circuits. Rated at 70º C to operate in high tempera- tures near solar modules. Specifications Housing: Durable, high impact Lexan® housing, ultrasonically welded Specifications for maximum strength. Nylon locknut provided. Compact in Housing: Weatherproof Lexan® housing. size, LCA series can be mounted directly within a lighting fix- ture or in lighting standards that are 2'' in diameter or larger. Turn-on: 1 to 3 foot-candles. Turn-on: 1 to 3 foot-candles. Turn-on/ 1: 1.5 Turn-off Ratio: Turn-on/ 1:1.5 Switch Type: Single-pole, single-throw. Contact position at night Turn-off Ratio: normally closed. Switch Type: Single-pole, single-throw. Contact position at night normally Time Delay: 1-5 seconds. closed. 1-5 seconds. Threaded Stem: 1/2 inch-14 thread, and fits 1/2 inch knock out. Time Delay: Swivel Series is equipped with a swivel mount which Threaded Stem: 3/8 inch-18 thread; threaded stem 3/4 inches long. allows installer to swivel light sensitive element to Dimensions: 2” high, 1-1/8” wide, 1-3/4” deep (2” deep w/threaded stem). the best position for operation. 2’’ high, 1-1/2’’ wide, 1’’ deep. Dimensions : “LCA” Series Power Dissipation: 12-1/2 MA@ 12VDC Model Voltage Rated Load LCA-612D 12 VDC 10 AMP “LCS” Series LCA-624A 24 VAC 10 AMP Model Voltage Rated Load LCA-624D 24 VDC 10 AMP LCS-612D 12 VDC 10 AMP† LCA-612AW* 12 VDC 10 AMP LCS-624D 24 VDC 10 AMP† LCA-624AW* 24 VAC 10 AMP * Wall plate models. LCS-624A 24 VAC 10 AMP† (See bottom of page 3 for wall LCA-624DW* 24 VDC 10 AMP plate dimensions.) † Non-inductive. Photocontrol 24 VAC ORANGE LOW VOLTAGE RED + CONTROL PHOTOCONTROLS Lamp Load Load (black) (red) WIRING DIAGRAMS (white) POWER Neutral LOAD (white) 48, 24 & BLACK Line (black) – 12 VDC (white) (black) TYPICAL WIRING (DC) 4 Locking Type, Low Voltage Lighting Applications LCP SERIES + M2ANB-LV Locking Type Receptacle Model M2ANB-LV for all low voltage, locking type control applications. Comes with housing and receptacle (½" threaded stem). See page 7 for model M2A. M2ANB-LV Specifications Locking-type, polarized receptacle with 14'' 48 VDC, 24 VDC and 12 VDC 14 AWG color coded leads Leads: Red (+). Black (-) and Orange (Load). Low Voltage Locking Type Dimensions: 2⁵⁄₈" high (incl. ½" stem), diameter 2 ¾" Photocontrols Rated Load: 10 AMP Available in 48 VDC, 24VDC & 12 VDC Rated at 170˚ F to operate in high temperatures near solar models. DO NOT USE WITH AC RECEPTacLES! Twistlock format for easy replacement. Precision's low-voltage twistlock system is designed for low voltage DC use only! To avoid LCP Specifications mis-application use Precision's low-voltage Housing: UV stabilized high-impact polypropylene base, M2ANB-LV with orange "load" wire. Sensor: Sealed Silicon Sensor Turn-on: 1 to 3 foot-candles Turn-on/ 1:1.5 Turn-off Ratio: LCP Low Voltage Wiring Diagrams Switch Type: Single-pole, single-throw. Contact position at night normally closed. DIRECT WIREIN Time Delay: 1 to 5 seconds. PHOTO CONTROL OR LOCKING TYPE RECEPTICAL Temperature -40˚ to 170˚ F load Range: red orange (+) to be Power 10 MA switched Dissipation: Rated Life: 5,000 operations minimum at rated load black Rated Load: 10 AMP Surge Protection: MOV (Metal Oxide Varistor) (-) Dimensions: 3.07” diameter, 2.15” high. DC color codes: Red = Positive (+) Ordering Guideline Orange = Load Model Voltage Rated Load Black = Negative (-) LCP-48 48 VDC 10 AMP LCP-24 24 VDC 10 AMP LCP-12 12 VDC 10 AMP 5 Locking-Type Photocontrols (120 - 285 Volts) C US C US Locking-Type Photocontrols- Utility-Grade Electronic Series Delayed Response Thermal Series Built-in time delay prevents false cycling caused by 1 to 1.5 on/off ratio for maximum energy savings.
Recommended publications
  • Multi-Voltage General Purpose Time Switch
    The First and Only... Multi-Voltage General Purpose Time Switch NOW GM40 40 AMPS! Standard Features… All in One Model! • 40 Amp Rating • Multi-Voltage: 120, 208/240, or 277 VAC • SPDT and DPDT ALL-IN-ONE! • NEMA 3R Outdoor Enclosure is Standard • No Tools Required • Power and Status LED Indicators • Real-Time Clock Face • Ground Lug and more…… One Timer is All You Need! GM40 The only electromechanical general purpose time switch with multi-voltage selection, 40 AMP rating, SPDT and DPDT contacts, and an indoor/outdoor NEMA 3R enclosure. All Standard in One Model for One Low Price. NEW Amber and Green Captive Trippers LED Lights Indicate Can’t Be Lost Power and Status NEW Easy Multi-Voltage Field Adjustable DIP Switch for Independently Adjust- 120, 208/240, able Trippers at 15 or 277 VAC Minute Intervals (2 hrs. for 7-day model) Real-Time Clock Face with ON/OFF/AUTO Override Switch NEW NEW New Compact NO TOOLS REQUIRED! VALOX® NEMA 3R Our “GUTS” simply snap Outdoor Enclosure into existing Grasslin or is Standard Intermatic enclosures NEW NEW Large Screw 40 Amp Terminals for Easy Wiring Rated Contacts #8 AWG NEW NEW Moisture Resistant Ground Lug Termination Conformal Coated Board File #E83486 Covered by U.S. Patent #6,563,237 GM40 – 120, 208/240 or 277 Volts – The only one to stock. SPECIFIERS GUIDE ELECTRICAL RATINGS: N.O. Contacts: Furnish and install a GM40 _ Multi-Volt Series 24 hour or (7 day) time switch with 40A Resistive @ 120~277VAC captive trippers and quartz or synchronous drive.
    [Show full text]
  • Ecm Operation Manual
    ECM OPERATION MANUAL FOR USE WITH MODELS: OL11-105FDBE OL16-125FDBE OL11-105RDBE OL16-125RDBE : IF YOU DO NOT FOLLOW THE SAFETY PRECAUTIONS BELOW AND IN THIS MANUAL, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. (REFERRED TO IN THESE INSTRUCTIONS AS A QUALIFIED HEATING CONTRACTOR). PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE PERFORMING ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE HOMEOWNER AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL. THERMO PRODUCTS, LLC. BOX 237 DENTON, NC 27239 PHONE: 800-476-4328 MADE IN USA MO-507 ECN 5577-MA 190924 All installations and services must be performed by qualified service personnel. INDEX SECTION BEGINNING PAG I. BLOWER CONTROL INFORMATION 1 A. TERMINAL DEFINITIONS & FIELD WIRING 1 B. WIRING & SWITCHES 2 C. INPUTS 4 D. OUTPUTS 4 E. OPERATING MODES 5 F. CFM TABLES 7 G. ECM SPECIFIC REPLACEMENT PARTS 8 III. ECM TROUBLESHOOTING 8 A. DIAGNOSTIC FEATURES 8 B. GENERAL GUIDELINES TO TROUBLESHOOTING GE ECM 9 C. TROUBLESHOOTING CHARTS 12 i i All installations and services must be performed by qualified service personnel. I. BLOWER CONTROLLER INFORMATION A. TERMINAL DEFINITIONS & FIELD WIRING Burner Harness Connector P1 Pin 1 – Limit switch connection. Pin 2 – 120 VAC Line connection. Pin 3 – Burner pilot contact. Pin 4&5 – 120 VAC Neutral connection.
    [Show full text]
  • Exterior Lighting Control Guidance
    Table of Contents 1 Welcome ............................................................................................................ 1 2 Why Control Lighting? ........................................................................................ 2 3 Control Strategies ............................................................................................... 3 4 Strategy Decisions ............................................................................................. 4 5 Strategies by Application .................................................................................... 5 6 Controls and Light Sources ................................................................................ 7 7 Energy Code Compliance................................................................................... 9 8 Lighting Control Devices..................................................................................... 12 9 Control Wiring..................................................................................................... 14 10 Control Zoning .................................................................................................... 16 11 Commissioning ................................................................................................... 18 12 Light Reduction Control using Occupancy Sensors ........................................... 21 CLTC Research .................................................................................................. 22 U.S. Department of Energy Research ...............................................................
    [Show full text]
  • EN Universal Timer Module
    MO144 Operators Guide EN Universal Timer Module MO144 | Operators Guide | Notices EN | 2 Copyright Notice Notice of Liability Unless otherwise indicated, this publication is the While every precaution has been taken in the copyright of Bosch Security Systems, Inc. (“Bosch”). preparation of this document, neither Bosch Security All rights are reserved. Systems, Inc. nor any of its official representatives You may download a single copy of this publication. shall have any liability to any person or entity with By downloading the publication you agree that you respect to any liability, loss or damage caused or will: (i) only use the publication for your own alleged to be caused directly or indirectly by the reference; (ii) not commercially exploit or charge any information contained in this book. person for the use of the publication; and (iii) not Bosch Security Systems, Inc. reserves the right to modify the publication in any way without the prior make changes to features and specifications at any written permission of Bosch. time without prior notification in the interest of Except as specified above or where authorised by the ongoing product development and improvement. Copyright Act 1968 (Cth), no part of this publication may be reproduced, transmitted, modified or stored, in any form or by any means, without the prior written permission of Bosch. Bosch Security Systems, Inc. | 3/08 | F01U000819-02 MO144 | Operators Guide | 1. Introduction EN | 3 1. Introduction Table 2: Operating Mode Switch Settings The programmable MO144 Universal Timer Module is designed to be one of the most adaptable timing units available. The universal timer module has eight Mode Mode Type 1 2 3 unique modes of operation and a flexible relay 1 One Shot Off Off Off output making the unit suitable for security 2 One Shot – Retriggerable On Off Off applications as well as for any other situation where 3 Strobe Reset Off On Off accurate time delays are required.
    [Show full text]
  • Preview Product
    Your Source for Automation & Control Components TM Certified System ISO 9001 QMI-SAI Global MAINS OR BACKUP LOW BATTERY OR BATTERY AUX REPLACEMENT MIN MAX OUT BATTERY DIAGNOSIS CHARGING LEVEL All in one PRODUCT PREVIEW NEW Products Push-in Technology Terminal Blocks Highlight & Features • No tool required for easy connection • Direct connection of solid wires and flexible wires with ferrules • Thinnest 3.5 mm wide terminal block in the industry • Can be opened quickly and easily and closed safely • Sizes up to 15.7 x 19.7 x 8.9 in Hinged Door • Good operability of components Enclosure • No restrictions for the assembly of internal fittings TECTI RO ON P IP67 KU363N DC Motor Disconnects Switches • KU363N DIN Rail Mountable Multi Function - 60A/48V DC (3 Pole in series) Wire Prep & • PV 132 RT Ferrule Crimper - 32A/48 V DC (1 Pole) • Automatically Loads Ferrule - Door mounting kit available • Crimps Ferrules from - Switching mechanism speed 20 AWG to 14AWG PV 132 RT is independent from the operator • Built in Lead Wire Stripper / Cutter 2 908.806.9400 - www.altechcorp.com Sensor & Actuator Cables & Connectors M8 & M12 • Molded Female Cable Assemblies • Field Wired Connectors • Panel Feed- Through Connectors Position switches Safety Rope Pull IN73 and MN78 Switch SRO • Especially suitable for switching low currents • Choose from metal or thermoplastic • Sophisticated combination of metal and/or enclosures and actuators plastic components • Emergency stop button available • Modular design with numerous actuators to upon request choose from • Max. rope length of 30 m Altech UL 489 with Dual Terminals A B C A Box terminal for solid conductors or flexible conductors with or without cable lug.
    [Show full text]
  • Installation & Operation
    Operating and Instruction Manual Manual No. MS717660 August 2003 MODEL S-5000 STATIONARY COMPOSITE VACUUM SAMPLER Manning Environmental, Inc. 1968 S. Austin Ave. Suite 101 Georgetown, Texas 78626 USA Office: (512) 863-9337 Fax: (512) 863-4472 E-Mail: [email protected] OPERATION AND MAINTENANCE of MANNING ENVIRONMENTAL, INC. MODEL S-5000 STATIONARY COMPOSITE STAMPLER Manual Part Number 717660 August 2003 Manning Environmental, Inc. 1968 South Austin Avenue Suite 101 Georgetown, Texas 78626-7808 Telephone: 512-863-9337 Fax: 512-863-4472 Copyright 2003, by Manning Environmental, Inc. All rights reserved. This work is protected by Copyright and other laws. Copying any aspect of this work is strictly prohibited. Warning! Dangerous electrical voltages are present in this equipment. Turn equipment off and disconnect power prior to servicing. Only qualified personnel should make electrical connections to the equipment Caution The pinch solenoid assemblies located underneath the measuring chambers close with great force. Do not place your fingers, tools or other items in their path while power is turned on. Caution Some fluids that are sampled may pose a health risk. Observe proper protective procedures when handling sample containers or any other parts of the equipment that has come in contact with the fluid. Caution The electronics enclosure and refrigerator are heavy. Observe caution when moving the equipment. i Manning Environmental Limited Factory Warranty Manning Environmental, Inc., warrants this product to the original purchaser against any defects that are due to faulty workmanship or material for a period of one year (365 days) from the date of shipment. During the warranty period Manning Environmental, Inc.
    [Show full text]
  • Time Switches – 24 Hour Dial 24 Hr. W/Skipper, Optional Carryover
    Time Switches – 24 Hour Dial T100 Series – Designed for industrial, commercial and residential applications. Highest HP ratings in the industry for loads up to 40 amps, providing direct 24 hr. control of most loads. Provides 1 to 12 “ON/OFF” operations each day with minimum ON/OFF times of 1 hour. All models equipped with one “ON” and one “OFF” tripper. Applications • Indoor/Outdoor Lighting • Post Lanterns • Signs • Pool Heaters • Filters • Hydrochlorinators • Air Conditioning • Blowers • Electric Fences • Pumps • Heating/Ventilating Systems • Music and Signal Systems • Fans • Poultry Foggers • Conveyers Specifications Case – Drawn steel 7-3/4" (19.7 cm) H, 5" (12.7 cm) W, 3" (7.6 cm) D in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"–3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases page for optional enclosures. Special Voltages and Cycles – See Time Switch Motors page for available motors. Switch Rating – Each Pole; 40 Amp Resistive, 120-480 VAC; 40 Amp Tungsten, inductive or 1000 VA pilot duty, 120-277 VAC; 2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC single phase; 7-1/2 HP (28 FLA) 208 VAC three phase; 10 HP (28 FLA) 240 VAC three phase. Model # Model # Clock Motor AMPS Model # w/See-Thru Cover Plastic Case Switch Volts 60 Hz (per pole) HP Rating T101 T101PCD82 T101P SPST 125 40 2 T102 –– T102P SPST 208-277 40 5 T103 T103PCD82 T103P DPST 125 40 2 T104 T104PCD82 T104P DPST 208-277 40 5 T101B* –– –– SPST 125 40 2 T105 –– –– 1NO / 1NC** 125 40 2 T106R† –– –– 1NO / 1NC** 208-277 40 5 * Separate clock motor terminals for switching circuits not on line voltage ** Can be wired as SPDT † Only available in NEMA 3R case For additional trippers (1 ON / 1 OFF per pack), order No.
    [Show full text]
  • Time Switches (Digital/Analogue), Sun Relays & Accessories
    Time Switches (digital/analogue), Sun Relays & Accessories Product Information July 2012 © 2012 Eaton Corporation. All rights reserved. New Products Dense Overview EATON Art.# EATON type designation Description Sun relay with integrated time switch 167377 SRCD1CO and external light sensor (2 - 2000 lx) Analogue sun relay with external light sensor 167378 SRSD1COW (2 - 2000 lx) Analogue sun relay with external light sensor 167375 SRSD1NO (2 - 100 lx) Analogue sun relay with integrated light sensor 167376 SRSW1NO for wall mounting (2-2000 lx) 167384 TSADCF DCF Antenna 167385 TSAGPSKIT Set: GPS antenna & power supply 167387 TSAMEM Memory key for OBELISK Software 167386 TSAMEMKIT PC Set: Interface, Software & memory key Digital time switch with week program 167379 TSDW1CO 1 channel Astronomical time switch with week program 167381 TSDW1COA 1 channel Digital time switch with week program 167382 TSDW1CODG 1 channel (connectable with external antenna) Digital time switch with week program 167383 TSDW1COMIN 1 channel, 1 module slim Digital time switch with week program 167380 TSDW2CO 2 channels Analogue time switch day program 167390 TSQD1CO 1 channel, quartz operated Analogue time switch with day program 167388 TSQD1NO 1 channel, quartz operated Analogue time switch week program 167392 TSQW1CO 1 channel, quartz operated Analogue time switch day program 167391 TSSD1CO 1 channel, grid freq. synchronized Analogue time switch with day program 167389 TSSD1NO 1 channel, grid freq. synchronized © 2012 Eaton Corporation. All rights reserved. 2 Type Key Explanation Sun Relay • SR S D 1NO • SR S W 1NO • SR C D 1CO • SR S D 1CO W SR …. Sun Relay S/C … Stand alone/Clock controlled D/W … DIN rail mounted/wall mounted 1CO/1NO … 1 change over/1normally open W … wide lux area (2…5000 lux) © 2012 Eaton Corporation.
    [Show full text]
  • Timers/Time Switches/Counters/Hour Meters T Imers/Time Switches/Counters/Hour Meters ’06–’07
    ’06–’07 Timers/Time Switches/Counters/Hour Meters T imers/Time Switches/Counters/Hour Meters ’06–’07 Switches/Counters/Hour imers/Time These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink. Ltd. Matsushita Electric Works, Please contact .......... Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan Telephone: +81-6-6908-1050 Facsimile: +81-6-6908-5781 http://www.nais-e.com/ Timers/Time Switches/Counters/Hour Meters All Rights Reserved © 2006 COPYRIGHT Matsushita Electric Works, Ltd. ARCT1B274E ’06.10 ARCT1B274E 200610-3YT Specifications are subject to change without notice. Printed in Japan. Matsushita Electric Works, Ltd. T ABLE OF CONTENTS Page Page TIMERS COUNTERS TIMERS CHART...........................................................2 COUNTERS SELECTOR CHART..............................93 TIMERS SELECTOR CHART.......................................3 TYPICAL COUNTER APPLICATIONS.......................94 ON-DELAY TIMER BASIC CIRCUIT............................7 COUNTER-RELATED TERMINOLOGY.....................95 TIMER-RELATED TERMINOLOGY .............................8 PRECAUTIONS IN USING THE COUNTER..............96 PRECAUTIONS IN USING THE TIMERS ..................10 LC2H Counters ...........................................................98 PM4S Timers ..............................................................13 LC2H Preset Counters..............................................106 PM4H-A/S/M
    [Show full text]
  • Lighting Controls
    LIGHTING CONTROLS HUMIDITY CONTROLS LIGHTING Kele Provides System and Zone Controls, with a Wide Variety of Peripheral Sensors and Switches. DLM Series | p. 615 AF16 Series | p. 664 LX-24 | p. 624 WSD Series | p. 637 CI-24 | p. 626 ET Series | p. 674 LIGHTING CONTROLS Products manufactured MODEL/SERIES PAGE in the United States Emergency Lighting Control ELCU-100 — WattStopper Emergency Lighting Control . 666 Products that are ELCU-200 — Emergency UL924 Bypass/ Shunt Relays . 668 new to the catalog ESR Series — Functional Devices UL924 Emergency Bypass / Shunt Relays . 670 Light Sensors MK7-B Series — PLC-Multipoint Celestial Self-Contained Ambient Light Sensors, Voltage Based . 643 PSR-1, PSR-1-T — Kele Photo-Sensitive Resistor . 645 K, LC Series — Photo Switches . 647 EM Series — Photo Switches . 649 MAS Series — PLC-Multipoint Self-Contained Ambient Light Sensors, Current Based . 650 Lighting Contactors and Relays HDR — Relay 5 Wire with Override and Connector . 660 RR-7, RR-9 — GE Lighting Relays . 661 2R7CDD, 2R9CDD — ILC Lighting Relays . 663 AF16 Series — ABB Lighting Contactors . 664 LIGHTING CONTROLS LS7K Series — AEG Lighting Contactors . 665 LMCP Series | p. 613 Lighting Panels and Control Products RP Basic Series — BlueRidge Relay Panels . 609 ZC Basic Series — BlueRidge Lighting Zone Controller . 611 LMCP Series — WattStopper Lighting Integrator Panels with Digital Lighting Management (DLM) Support . 613 DLM Series Digital Lighting Management — Digital Lighting Controls . 615 LC8 Series — WattStopper Modular Contractor Panel . .. 618 CX Series Commercial Lighting Control Panels — Standalone Programmable Lighting Control Panel . 620 ILC Apprentice II — Programmable Lighting Control Panel . 622 PIL-1 — Kele Pulse Initiator . 658 LDIM2 — Kele Fluorescent Dimming Control Module .
    [Show full text]
  • Make Your House Smarter +
    xComfort Make your house smarter + + + + + + + What is xComfort? Functions and solutions Who can use xComfort? xComfort is a wireless control system for all the The xComfort system can be used for anything electrical equipment in your home, which gives from updating existing installations or extending the house smarter functions, greater security and and improving them, all the way up to setting up increased comfort. completely new installations. You can start small, with simple and practical functions, and expand The advantages: the system later as the need or desire arises. Do • less power consumption you need to install an extra light switch in the hall, • flexible design tailored to your style or at both the top and bottom of the stairs? These are basic tasks that xComfort is used for • controls your lights and heating every day, with absolutely no mess or visible • increased security cables. Since installing xComfort usually involves • wireless control making changes to electrical systems, it does need • no unsightly cables to be installed by a qualified electrician. For advice • remote control via smartphone or web and assistance, consult your local Eaton sales engineer or local xComfort installer. 2 Control your house from the other side of the world Installing an xComfort system with a Smart Home forget to do it yourself. Simply having a master switch Controller will give you full remote access of anything by the entrance can let you switch off all the lights in the electrical within the home or controlled environment, house with a single press of a button, and upon return from anywhere in the world.
    [Show full text]
  • Manual & Digital Time Switches
    MISCELLANEOUS CONTROLS MANUAL & DIGITAL TIME SWITCHES 93000, TS-200 SERIES DESCRIPTION The Marktime 93000 Series Wall Box Manual Time Switch is a spring-wound, manually set time switch for the control of electrical current. Interchangeable with standard toggle switch- es to turn circuits either off or on at the end of a preset time period, the 93000 Series is ideally suited for new installations or retrofit projects. FEATURES • White and ivory plates and knobs included with each MISCELLANEOUS CONTROLS time switch • Heavy motor loads without the need of contactors •Time ranges from minutes to 12 hours, all with ±5% •Rotary knob operation accuracy • Available to turn circuits off or on, with or • Easy-to-install two-wire design to fit into standard without manual hold override feature single-gang wall box • UL listed, CUL ORDERING INFORMATION MODEL DESCRIPTION MODEL DESCRIPTION No Hold Previous With Hold Previous 93000 SERIES 93501C (90005/90539) 0-15 Min N.O./N.C. 93511C (90012/90543) 0-15 Min N.O./N.C. (w/hold) 93502C (90006/90032) 0-30 Min N.O./N.C. 93512C (90011/90037) 0-30 Min N.O./N.C. (w/hold) ELECTRICAL RATING 93503C (90008/90024) 0-60 Min N.O./N.C. 93513C (90010/90038) 0-60 Min N.O./N.C. (w/hold) 20A 125 VAC 1 hp 93504C (90281/90540) 0-120 Min N.O./N.C. 10A 277 VAC 93505C (90007/90017) 0-6 Hour N.O./N.C. 93515C (90017/90548) 0-6 Hour N.O./N.C. (w/hold) 93506C (90001/90015) 0-12 Hour N.O./N.C.
    [Show full text]