Controllers & Sensors

Total Page:16

File Type:pdf, Size:1020Kb

Controllers & Sensors Controllers & Sensors Ecotronic Controller Surface T-Series® Controller Surface TimeSpan® Controller Mounting Mounting Adjustable timer with overrun facility for fans An electronic controller for use with all A single unit controller for use with all Traditional ventilating WCs and other small rooms. Traditional T-Series and Standard Range T-Series ventilating units. With knockouts for models to give extract/intake and speed recessed wiring. Where a controller is used For use with any Vent-Axia fan within maximum variation. For groups of units of any one with T-Series, 5-core flexible cable is required. rating below. The fan is switched On with the size up to a total of 400 Watts. Do not mix light and keeps running for a pre-set period T-Series with Standard Range. Where a • 3-speed operation. High, medium or after the light is switched Off. controller is used with T-Series, 5-core flexible low. cable is required. • Finger-tip sliders. • Fits to any single gang box. • Double pole On/Off switching. • Adjustable time delay 5-25 minutes. • ‘E’ running position for optimum • Extract/intake airflow direction. • Ambient operating temperature range efficiency. • Sensor mode for use with suitable 0°C to + 40°C. • Finger-tip sliders. electromechanical switches, eg. • Maximum load 250W inductive. • Infinitely variable speed control. ThermoSwitch, HumidiSwitch to give • BEAB approved. • Double pole On/Off switching. automatic fan operation. • Dimensions: • Extract/intake airflow direction. • Unique shutter open/ fan Off setting. 87 x 87 x 33mm (H x W x D). • Neon indicator. • Neon indicator. • Supply voltage 220-240V/1/50Hz. • Sensor mode for use with suitable • Knockouts for recessed wiring. • Will fit single gang box for surface electromechanical switches, eg. • Ambient operating temperature range mounting. ThermoSwitch, HumidiSwitch to give 0°C to +40°C. automatic fan operation. • Dimensions: 86 x 156 x 53mm Stock Ref £Trade • Adjustable minimum speed setting. (H x W x D). 563519 78.49 • Knockouts for recessed wiring. • Supply voltage 220-240V/1/50Hz. • Ambient operating temperature range • Designed to meet IP20. Surface Mounting Box 0°C to +40°C. • BEAB approved. A surface mounting back box is available. • Dimensions: 86 x 156 x 53mm Stock Ref £Trade (H x W x D). Stock Ref £Trade 410020 9.49 • Supply voltage 220-240V/1/50Hz. W361119 114.81 • Maximum load: Ecotronic - 400 Watts. • Designed to meet IP20. Flush Fitting Box • BEAB approved. Stock Ref £Trade 400144 13.01 Stock Ref £Trade W362320 157.37 Flush Fitting Box Stock Ref £Trade 400144 13.01 Registered design numbers: 1 030 207 Surface Mounting Controller, 1 030 208 Flush Fitting Controller. Patented Remote Speed Control Circuit. European Patent number EP 0180311. Air Quality Sensor Electronic 1.5A Controller HR500 Controller Automatically reacts to the depletion of air Surface mounted, providing infinitely variable Suitable for use with HR500 MVHR units. quality, sensing unpleasant smells and toilet speed control and features an On/Off/ Surface mounting. On/Off remote sensor odours to regulate mechanically ventilated sensor slider with neon indicator. There is mode. Heat exchange, single fan extract areas such as cinemas, pubs, clubs, an adjustable minimum speed setting. The or twin fan extract modes. Infinitely variable restaurants, kitchens, toilets and conference controller is radio suppressed to BS EN speed. Minimum speed setting. rooms. This is not a CO sensor. 55014 and electrical connections for use 2 Stock Ref £Trade with suitable external sensors are provided. W14301010 166.55 The sensor switches the fan On when the air quality declines below an adjustable preset 86 x 156 x 53mm (H x W x D). level. This is registered by the ceramic sensing head which is self-cleaning, a process which Hole for wall box: occurs every time the unit is triggered. When 80x150x150mm (H x W x D). the atmosphere has returned to normal, the fan will continue to run for a pre-set period Stock Ref (adjustable between 1-25 minutes) and then £Trade switch Off. W300310 107.62 The air quality sensor should not be used for the detection of combustible gases and is not designed for use as a smoke detector in an For flush fitting a metal wall box accessory is alarm system. available. Flush fitting box For use with various Vent-Axia fans within Stock Ref maximum rating below. £Trade 400144 The Air Quality Sensor is also able to switch 13.01 between trickle and boost speed on the appropriate ventilation units. • Ambient operating temperature range 0°C to +50°C. • Dimensions: 87 x 157 x 47mm (H x W x D). • Maximum switched load: 2A inductive at 240V. • Sensor consumption: 25mA at 240V. • Supply voltage 240V/1/50Hz. Stock Ref £Trade 563506 237.16 Controllers & Sensors Ambient Response SELV 12 Lo-Carbon Ambient Ambient Response Humidity Sensor Humidity Sensor Response Humidity Sensor A self programming electronic On/Off wall 12V Safety Extra Low Voltage version for use Designed specifically for the Lo-Carbon mounted humidity sensor which reacts to any with VA100 SELV, Solo SELV, LuminAir SELV product range. This self programming rapid increase in humidity and temperature and HR100 SELV range. electronic On/Off wall mounted humidity by switching a Vent-Axia fan ‘On’ for rapid sensor reacts to any rapid increase in removal of moisture laden air in domestic The latest self programming electronic On/ humidity and temperature by switching a Vent- bathrooms and kitchens. Can be wired into Off wall mounted humidity sensor which Axia fan ‘On’ for rapid removal of moisture controller ‘Auto’ mode connections. Night reacts to any rapid increase in humidity and laden air in domestic bathrooms and kitchens. time relative humidity increment setback temperature by switching a Vent-Axia fan Night time relative humidity increment setback feature suppresses nuisance tripping when ‘On’ for rapid removal of moisture laden air feature suppresses nuisance tripping when the humidity level gradually rises as the in domestic bathrooms and kitchens. Can be the humidity level gradually rises as the temperature falls. wired into controller ‘Auto’ mode connections. temperature falls. Night time relative humidity increment setback • Pullcord override and neon indicator. feature suppresses nuisance tripping when • Pullcord override and neon indicator. • Changeover relay switch. the humidity level gradually rises as the • Changeover relay switch. • Operating range: 30%-90%RH. temperature falls. • Operating range: 30%-90%RH. • Ambient operating temperature +5°C • Ambient operating temperature +5°C to +40°C. • Pullcord override and neon indicator. to +40°C. • Dimensions: • Changeover relay switch. • Dimensions: 87 x 87 x 33mm (H x W x D). • Operating range: 30%-90%RH. 87 x 87 x 33mm (H x W x D). • Will fit single gang box for surface • Ambient operating temperature +5°C • Will fit single gang box for surface mounting. to +40°C. mounting. • Dimensions: Stock Ref £Trade 87 x 87 x 33mm (H x W x D). Stock Ref £Trade 563550 240VAC 50Hz 212.88 • Will fit single gang box for surface 563552 12VDC 212.88 mounting. European Patent No: 2298057 Surface Mounting Box Stock Ref £Trade A surface mounting back box is available. Surface Mounting Box 563551 12VAC 50Hz 212.88 Stock Ref £Trade A surface mounting back box is available. 410020 9.49 Stock Ref £Trade Surface Mounting Box 410020 9.49 A surface mounting back box is available. Stock Ref £Trade 410020 9.49 All of these Sensors can be wired for either On/Off or Trickle/Boost operation. Ecotronic Humidity Sensor Ecotronic® SELV 12 Humidity Sensor Vent-Axia HumidiSwitch Surface Mounting 12V Safety Extra Low Voltage version for use Operates Vent-Axia ventilating units on either An adjustable set point, solid state On/Off with VA100 SELV, Solo SELV, and LuminAir a rise or a fall in humidity to control the sensor. A pullcord provides manual override, SELV range. Incorporates changeover switch damaging effects of condensation. indicated by lamp. Adjustable from 65 to 90% to select low/high speed. relative humidity. Can be wired into controller • Concealed adjustment. ‘Auto’ mode connections. Incorporates Although suitable for siting within reach of a • Setting range 20% to 80% RH. changeover switch to select low/high speed. shower or bath we recommend this model is • Ambient operating temperature 0°C to located out of the spray zone of a bath or +50°C. • Setting range 65% - 90%RH. shower. • Dimensions: 82 x 132 x 40mm (H x • Maximum switching load 1 Amp W x D). inductive. • Setting range 65% - 90%RH. • Rating 2A (1A inductive). • Pullcord override indicated by lamp. • Maximum switching load 5.6A @ 12V • Switching range 120-240V. • Ambient operating temperature 0°C to AC. • Designed for use with controllers with +40°C. • Pullcord override indicated by lamp. ‘Auto’ mode facility. • Dimensions: 87 x 87 x 33mm. • Ambient operating temperature 0°C to • Single pole changeover contacts. (H x W x D). +40°C. • Supply voltage 220-240V/1/50Hz. • Dimensions: 87 x 87 x 33mm Stock Ref £Trade (H x W x D). 563501 102.43 Stock Ref £Trade • Supply voltage 12V AC. 563532 118.26 Stock Ref £Trade Surface Mounting Box 563531 118.26 A surface mounting back box is available. Stock Ref £Trade Surface Mounting Box 410020 9.49 A surface mounting back box is available. Stock Ref £Trade 410020 9.49 The Ecotronic and Ecotronic SELV 12 Sensor can be wired for either On/Off or Trickle/Boost operation. Controllers & Sensors 7 Day TimeSwitch Vent-Axia ThermoSwitch Guardian Personnel Detector For applications where regular switching is Automatically switches On fans on either a rise (PIR Sensor) required at fixed periods or at different times or fall in air temperature. The ThermoSwitch Suitable for controlling a range of Vent-Axia on different days of the week, eg: offices, can be used with all Vent-Axia fans (via fans.
Recommended publications
  • Multi-Voltage General Purpose Time Switch
    The First and Only... Multi-Voltage General Purpose Time Switch NOW GM40 40 AMPS! Standard Features… All in One Model! • 40 Amp Rating • Multi-Voltage: 120, 208/240, or 277 VAC • SPDT and DPDT ALL-IN-ONE! • NEMA 3R Outdoor Enclosure is Standard • No Tools Required • Power and Status LED Indicators • Real-Time Clock Face • Ground Lug and more…… One Timer is All You Need! GM40 The only electromechanical general purpose time switch with multi-voltage selection, 40 AMP rating, SPDT and DPDT contacts, and an indoor/outdoor NEMA 3R enclosure. All Standard in One Model for One Low Price. NEW Amber and Green Captive Trippers LED Lights Indicate Can’t Be Lost Power and Status NEW Easy Multi-Voltage Field Adjustable DIP Switch for Independently Adjust- 120, 208/240, able Trippers at 15 or 277 VAC Minute Intervals (2 hrs. for 7-day model) Real-Time Clock Face with ON/OFF/AUTO Override Switch NEW NEW New Compact NO TOOLS REQUIRED! VALOX® NEMA 3R Our “GUTS” simply snap Outdoor Enclosure into existing Grasslin or is Standard Intermatic enclosures NEW NEW Large Screw 40 Amp Terminals for Easy Wiring Rated Contacts #8 AWG NEW NEW Moisture Resistant Ground Lug Termination Conformal Coated Board File #E83486 Covered by U.S. Patent #6,563,237 GM40 – 120, 208/240 or 277 Volts – The only one to stock. SPECIFIERS GUIDE ELECTRICAL RATINGS: N.O. Contacts: Furnish and install a GM40 _ Multi-Volt Series 24 hour or (7 day) time switch with 40A Resistive @ 120~277VAC captive trippers and quartz or synchronous drive.
    [Show full text]
  • SWEETA Catalog 2019
    Index About Us Established in 1995, SWEETA is a professional manufacturer of all kinds of Metal Push Button Switch 01 switches, AC sockets, as well as circuit breakers. Most of our products have been certified to meet international safety standards such as RoHS, UL, CSA, Navigation Switch 02 ENEC, VDE and others. We are continuously developing new products to catch up with the Rocker/Mini Rocker Switch & Toggle/Mini Toggle Switch 03 ever-changing market demands. We do accept OEM projects. Excellent quality products, competitive prices, prompt delivery and royal service are guaranteed. At present, we are extending our business to Europe, US, Asia, Push Button Switch & Mini Push Switch 04 Far East countries. Micro/Mini Micro Switch & Hook Switch 05 Tact Switch (Illuminated) & Cap 06 DC Slide Switch & DC Connecter (DC JACK/USB/RJ45/CCTV) 07 Quality Policy DIP & Digital & Rotary & Key Switch 08 To customer service policy Illuminate Push Button Switch & Indicator Light 09 We regard the customer satisfaction as our pride and honor. Sensor & Detector & Reed Switch 10 Comprehensive Quality Control Our strict and comprehensive QC process guarantees the most reliable AC Socket & EMI Filter 11 products. Receptacle & Plug Adapter 12 High Standards Be it in the process of material selection or during product manufacturing, Circuit Breaker & Fuse & Fuse Holder & Thermostat 13 we are doing it with unremitting innovation and improvement in order to achieve the highest international standards. AC Power Cord 14 Terminal Block 15 Please contact with us for more information. Metal Push Button Switch Navigation Switch Metal Push Button Switch Navigation Switch SPECIFICATION: SPECIFICATION: Rating: 3A 250V AC/5A 250V AC/10A 250V AC Switch Circuit: SP5T 0.2A 36V DC/3A 36V DC Current Rating: 50mA Mounting Hole: Ø8~40 mm Voltage Rating: 12VDC Operating Temperature: -20 °C ~ +55 °C Contact Resistance: 100mΩ Max.
    [Show full text]
  • Photocontrols & Timers
    PMC-CAt-609 PHOTOCONTROLS & TIMERS TO SAVE ENERGY FOR OVER 50 YEARS. PMC-CAT-09-12 Locking Type Photocontrol 12V to 480V Button-Type In Fixture Direct Wire In Photocontrol Photocontrol Pole Mounted Digital Locking Type Push Button Auxillary Power Tap In Wall Timer 6-in-1 Schedules End Sensing Energy Saving Photocontrol /Timer On At Dusk, Off At Your Pre-Set Time Low Voltage Adjustable Photocontrols "Barrel" Type 12 & 24 VAC Photocontrol 24 VDC Easy On/Off Field Setting On Base. Lighting General Purpose Contactor 24 Hour 30 & 60 AMP Time Switch 40 AMP CUSTOMER PHONE SERVICE ALWAYS AVAILABLE 9AM TO 5PM WEEKDAYS EST 201-444-0600 Direct Wire-In Photocontrols (120 - 480 Volts) Heavy-duty Die-cast Enclosure Vandal Proof Lumatrol® “T” Series Lumatrol® “T-30” Wire-In Photo Control - 3000 Watts Cast Aluminum Housing photocontrols - Designed for Designed for those applications which demand more those locations where high vandalism creates high load switching than standard 15 amp. series can maintenance. The heavy-duty cast aluminum housing handle. is 20 times more resistant to high-impact objects (i.e. rocks, bats or small projectiles) than plastic housing. Specifications As the controlling element of the total lighting pack- Housing: Lexan enclosure. age (fixture, lamp ballast) and the least costly compo- Photocell: Broad surface sensing element. nent, it is most important that the control continue to Turn-on: 1 to 3 foot-candles. External light level slide allows function under all adverse conditions. field adjustment between 3 to 10 foot-candles. Specifications Turn-on/ 1:3 Turn-off Ratio: Housing: Vandal proof die cast aluminum housing.
    [Show full text]
  • Ecm Operation Manual
    ECM OPERATION MANUAL FOR USE WITH MODELS: OL11-105FDBE OL16-125FDBE OL11-105RDBE OL16-125RDBE : IF YOU DO NOT FOLLOW THE SAFETY PRECAUTIONS BELOW AND IN THIS MANUAL, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. (REFERRED TO IN THESE INSTRUCTIONS AS A QUALIFIED HEATING CONTRACTOR). PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE PERFORMING ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE HOMEOWNER AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL. THERMO PRODUCTS, LLC. BOX 237 DENTON, NC 27239 PHONE: 800-476-4328 MADE IN USA MO-507 ECN 5577-MA 190924 All installations and services must be performed by qualified service personnel. INDEX SECTION BEGINNING PAG I. BLOWER CONTROL INFORMATION 1 A. TERMINAL DEFINITIONS & FIELD WIRING 1 B. WIRING & SWITCHES 2 C. INPUTS 4 D. OUTPUTS 4 E. OPERATING MODES 5 F. CFM TABLES 7 G. ECM SPECIFIC REPLACEMENT PARTS 8 III. ECM TROUBLESHOOTING 8 A. DIAGNOSTIC FEATURES 8 B. GENERAL GUIDELINES TO TROUBLESHOOTING GE ECM 9 C. TROUBLESHOOTING CHARTS 12 i i All installations and services must be performed by qualified service personnel. I. BLOWER CONTROLLER INFORMATION A. TERMINAL DEFINITIONS & FIELD WIRING Burner Harness Connector P1 Pin 1 – Limit switch connection. Pin 2 – 120 VAC Line connection. Pin 3 – Burner pilot contact. Pin 4&5 – 120 VAC Neutral connection.
    [Show full text]
  • Exterior Lighting Control Guidance
    Table of Contents 1 Welcome ............................................................................................................ 1 2 Why Control Lighting? ........................................................................................ 2 3 Control Strategies ............................................................................................... 3 4 Strategy Decisions ............................................................................................. 4 5 Strategies by Application .................................................................................... 5 6 Controls and Light Sources ................................................................................ 7 7 Energy Code Compliance................................................................................... 9 8 Lighting Control Devices..................................................................................... 12 9 Control Wiring..................................................................................................... 14 10 Control Zoning .................................................................................................... 16 11 Commissioning ................................................................................................... 18 12 Light Reduction Control using Occupancy Sensors ........................................... 21 CLTC Research .................................................................................................. 22 U.S. Department of Energy Research ...............................................................
    [Show full text]
  • EN Universal Timer Module
    MO144 Operators Guide EN Universal Timer Module MO144 | Operators Guide | Notices EN | 2 Copyright Notice Notice of Liability Unless otherwise indicated, this publication is the While every precaution has been taken in the copyright of Bosch Security Systems, Inc. (“Bosch”). preparation of this document, neither Bosch Security All rights are reserved. Systems, Inc. nor any of its official representatives You may download a single copy of this publication. shall have any liability to any person or entity with By downloading the publication you agree that you respect to any liability, loss or damage caused or will: (i) only use the publication for your own alleged to be caused directly or indirectly by the reference; (ii) not commercially exploit or charge any information contained in this book. person for the use of the publication; and (iii) not Bosch Security Systems, Inc. reserves the right to modify the publication in any way without the prior make changes to features and specifications at any written permission of Bosch. time without prior notification in the interest of Except as specified above or where authorised by the ongoing product development and improvement. Copyright Act 1968 (Cth), no part of this publication may be reproduced, transmitted, modified or stored, in any form or by any means, without the prior written permission of Bosch. Bosch Security Systems, Inc. | 3/08 | F01U000819-02 MO144 | Operators Guide | 1. Introduction EN | 3 1. Introduction Table 2: Operating Mode Switch Settings The programmable MO144 Universal Timer Module is designed to be one of the most adaptable timing units available. The universal timer module has eight Mode Mode Type 1 2 3 unique modes of operation and a flexible relay 1 One Shot Off Off Off output making the unit suitable for security 2 One Shot – Retriggerable On Off Off applications as well as for any other situation where 3 Strobe Reset Off On Off accurate time delays are required.
    [Show full text]
  • Preview Product
    Your Source for Automation & Control Components TM Certified System ISO 9001 QMI-SAI Global MAINS OR BACKUP LOW BATTERY OR BATTERY AUX REPLACEMENT MIN MAX OUT BATTERY DIAGNOSIS CHARGING LEVEL All in one PRODUCT PREVIEW NEW Products Push-in Technology Terminal Blocks Highlight & Features • No tool required for easy connection • Direct connection of solid wires and flexible wires with ferrules • Thinnest 3.5 mm wide terminal block in the industry • Can be opened quickly and easily and closed safely • Sizes up to 15.7 x 19.7 x 8.9 in Hinged Door • Good operability of components Enclosure • No restrictions for the assembly of internal fittings TECTI RO ON P IP67 KU363N DC Motor Disconnects Switches • KU363N DIN Rail Mountable Multi Function - 60A/48V DC (3 Pole in series) Wire Prep & • PV 132 RT Ferrule Crimper - 32A/48 V DC (1 Pole) • Automatically Loads Ferrule - Door mounting kit available • Crimps Ferrules from - Switching mechanism speed 20 AWG to 14AWG PV 132 RT is independent from the operator • Built in Lead Wire Stripper / Cutter 2 908.806.9400 - www.altechcorp.com Sensor & Actuator Cables & Connectors M8 & M12 • Molded Female Cable Assemblies • Field Wired Connectors • Panel Feed- Through Connectors Position switches Safety Rope Pull IN73 and MN78 Switch SRO • Especially suitable for switching low currents • Choose from metal or thermoplastic • Sophisticated combination of metal and/or enclosures and actuators plastic components • Emergency stop button available • Modular design with numerous actuators to upon request choose from • Max. rope length of 30 m Altech UL 489 with Dual Terminals A B C A Box terminal for solid conductors or flexible conductors with or without cable lug.
    [Show full text]
  • Installation & Operation
    Operating and Instruction Manual Manual No. MS717660 August 2003 MODEL S-5000 STATIONARY COMPOSITE VACUUM SAMPLER Manning Environmental, Inc. 1968 S. Austin Ave. Suite 101 Georgetown, Texas 78626 USA Office: (512) 863-9337 Fax: (512) 863-4472 E-Mail: [email protected] OPERATION AND MAINTENANCE of MANNING ENVIRONMENTAL, INC. MODEL S-5000 STATIONARY COMPOSITE STAMPLER Manual Part Number 717660 August 2003 Manning Environmental, Inc. 1968 South Austin Avenue Suite 101 Georgetown, Texas 78626-7808 Telephone: 512-863-9337 Fax: 512-863-4472 Copyright 2003, by Manning Environmental, Inc. All rights reserved. This work is protected by Copyright and other laws. Copying any aspect of this work is strictly prohibited. Warning! Dangerous electrical voltages are present in this equipment. Turn equipment off and disconnect power prior to servicing. Only qualified personnel should make electrical connections to the equipment Caution The pinch solenoid assemblies located underneath the measuring chambers close with great force. Do not place your fingers, tools or other items in their path while power is turned on. Caution Some fluids that are sampled may pose a health risk. Observe proper protective procedures when handling sample containers or any other parts of the equipment that has come in contact with the fluid. Caution The electronics enclosure and refrigerator are heavy. Observe caution when moving the equipment. i Manning Environmental Limited Factory Warranty Manning Environmental, Inc., warrants this product to the original purchaser against any defects that are due to faulty workmanship or material for a period of one year (365 days) from the date of shipment. During the warranty period Manning Environmental, Inc.
    [Show full text]
  • Time Switches – 24 Hour Dial 24 Hr. W/Skipper, Optional Carryover
    Time Switches – 24 Hour Dial T100 Series – Designed for industrial, commercial and residential applications. Highest HP ratings in the industry for loads up to 40 amps, providing direct 24 hr. control of most loads. Provides 1 to 12 “ON/OFF” operations each day with minimum ON/OFF times of 1 hour. All models equipped with one “ON” and one “OFF” tripper. Applications • Indoor/Outdoor Lighting • Post Lanterns • Signs • Pool Heaters • Filters • Hydrochlorinators • Air Conditioning • Blowers • Electric Fences • Pumps • Heating/Ventilating Systems • Music and Signal Systems • Fans • Poultry Foggers • Conveyers Specifications Case – Drawn steel 7-3/4" (19.7 cm) H, 5" (12.7 cm) W, 3" (7.6 cm) D in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"–3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases page for optional enclosures. Special Voltages and Cycles – See Time Switch Motors page for available motors. Switch Rating – Each Pole; 40 Amp Resistive, 120-480 VAC; 40 Amp Tungsten, inductive or 1000 VA pilot duty, 120-277 VAC; 2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC single phase; 7-1/2 HP (28 FLA) 208 VAC three phase; 10 HP (28 FLA) 240 VAC three phase. Model # Model # Clock Motor AMPS Model # w/See-Thru Cover Plastic Case Switch Volts 60 Hz (per pole) HP Rating T101 T101PCD82 T101P SPST 125 40 2 T102 –– T102P SPST 208-277 40 5 T103 T103PCD82 T103P DPST 125 40 2 T104 T104PCD82 T104P DPST 208-277 40 5 T101B* –– –– SPST 125 40 2 T105 –– –– 1NO / 1NC** 125 40 2 T106R† –– –– 1NO / 1NC** 208-277 40 5 * Separate clock motor terminals for switching circuits not on line voltage ** Can be wired as SPDT † Only available in NEMA 3R case For additional trippers (1 ON / 1 OFF per pack), order No.
    [Show full text]
  • Time Switches (Digital/Analogue), Sun Relays & Accessories
    Time Switches (digital/analogue), Sun Relays & Accessories Product Information July 2012 © 2012 Eaton Corporation. All rights reserved. New Products Dense Overview EATON Art.# EATON type designation Description Sun relay with integrated time switch 167377 SRCD1CO and external light sensor (2 - 2000 lx) Analogue sun relay with external light sensor 167378 SRSD1COW (2 - 2000 lx) Analogue sun relay with external light sensor 167375 SRSD1NO (2 - 100 lx) Analogue sun relay with integrated light sensor 167376 SRSW1NO for wall mounting (2-2000 lx) 167384 TSADCF DCF Antenna 167385 TSAGPSKIT Set: GPS antenna & power supply 167387 TSAMEM Memory key for OBELISK Software 167386 TSAMEMKIT PC Set: Interface, Software & memory key Digital time switch with week program 167379 TSDW1CO 1 channel Astronomical time switch with week program 167381 TSDW1COA 1 channel Digital time switch with week program 167382 TSDW1CODG 1 channel (connectable with external antenna) Digital time switch with week program 167383 TSDW1COMIN 1 channel, 1 module slim Digital time switch with week program 167380 TSDW2CO 2 channels Analogue time switch day program 167390 TSQD1CO 1 channel, quartz operated Analogue time switch with day program 167388 TSQD1NO 1 channel, quartz operated Analogue time switch week program 167392 TSQW1CO 1 channel, quartz operated Analogue time switch day program 167391 TSSD1CO 1 channel, grid freq. synchronized Analogue time switch with day program 167389 TSSD1NO 1 channel, grid freq. synchronized © 2012 Eaton Corporation. All rights reserved. 2 Type Key Explanation Sun Relay • SR S D 1NO • SR S W 1NO • SR C D 1CO • SR S D 1CO W SR …. Sun Relay S/C … Stand alone/Clock controlled D/W … DIN rail mounted/wall mounted 1CO/1NO … 1 change over/1normally open W … wide lux area (2…5000 lux) © 2012 Eaton Corporation.
    [Show full text]
  • Timers/Time Switches/Counters/Hour Meters T Imers/Time Switches/Counters/Hour Meters ’06–’07
    ’06–’07 Timers/Time Switches/Counters/Hour Meters T imers/Time Switches/Counters/Hour Meters ’06–’07 Switches/Counters/Hour imers/Time These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink. Ltd. Matsushita Electric Works, Please contact .......... Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan Telephone: +81-6-6908-1050 Facsimile: +81-6-6908-5781 http://www.nais-e.com/ Timers/Time Switches/Counters/Hour Meters All Rights Reserved © 2006 COPYRIGHT Matsushita Electric Works, Ltd. ARCT1B274E ’06.10 ARCT1B274E 200610-3YT Specifications are subject to change without notice. Printed in Japan. Matsushita Electric Works, Ltd. T ABLE OF CONTENTS Page Page TIMERS COUNTERS TIMERS CHART...........................................................2 COUNTERS SELECTOR CHART..............................93 TIMERS SELECTOR CHART.......................................3 TYPICAL COUNTER APPLICATIONS.......................94 ON-DELAY TIMER BASIC CIRCUIT............................7 COUNTER-RELATED TERMINOLOGY.....................95 TIMER-RELATED TERMINOLOGY .............................8 PRECAUTIONS IN USING THE COUNTER..............96 PRECAUTIONS IN USING THE TIMERS ..................10 LC2H Counters ...........................................................98 PM4S Timers ..............................................................13 LC2H Preset Counters..............................................106 PM4H-A/S/M
    [Show full text]
  • EMF-2 / EMF-2M Multi-Function Timer
    EMF-2 / EMF-2m Multi-Function Timer 5502 Timberlea Blvd., Mississauga, ON L4W 2T7 Telephone: 905-366-3377 Fax: 905-366-3378 Installation Instructions Toll-Free: 1-877-226-3369 Ver. A1-001 Web: www.camdencontrols.com MADE IN CANADA PAGE 1 OF 19 Section 1__________________ General Description Wiring Wiring of this unit is dependant on the mode desired. Camden model EMF-2 (EMF-2m or EMF-2ABM) is a microprocessor controlled multi-function relay. This Select your intended application, then proceed to the section indicated. all-in-one design replaces our previous models EMF-1, EMF-1m or EMF-1ABM. Note: Do not wire Safety devices to the EMF-2. If The EMF-2 is designed for specialized applications installed, wire your safety device directly to the operator control box. such as ABM vestibules, one or two-door restrooms in shared-use facilities, 2 – 5 door airlocks, and IMPORTANT: Changes to the Mode and Out2 secure man-traps. do not take effect until a power reset. It is therefore Dip switches let you easily choose the mode, and the best to make these adjustments with the power unit automatically programs the inputs, outputs and turned off! potentiometers accordingly. NOTE: We highly recommend the use of a Removable terminal strips simplify wiring chores, and regulated power supply when powering equipment for all adjustments are conveniently located on one end barrier-free washroom applications where the strike power may be maintained from a few minutes to of the case. many hours. We offer a low-cost board-only IMPORTANT: Do not apply power to the unit until regulated power supply - CX-PS13 V2, which in turn you have read the instructions fully and made the can be powered from a small 24VAC transformer, (or required adjustments.
    [Show full text]