Photocontrols & Timers

Photocontrols & Timers

PMC-CAt-609 PHOTOCONTROLS & TIMERS TO SAVE ENERGY FOR OVER 50 YEARS. PMC-CAT-09-12 Locking Type Photocontrol 12V to 480V Button-Type In Fixture Direct Wire In Photocontrol Photocontrol Pole Mounted Digital Locking Type Push Button Auxillary Power Tap In Wall Timer 6-in-1 Schedules End Sensing Energy Saving Photocontrol /Timer On At Dusk, Off At Your Pre-Set Time Low Voltage Adjustable Photocontrols "Barrel" Type 12 & 24 VAC Photocontrol 24 VDC Easy On/Off Field Setting On Base. Lighting General Purpose Contactor 24 Hour 30 & 60 AMP Time Switch 40 AMP CUSTOMER PHONE SERVICE ALWAYS AVAILABLE 9AM TO 5PM WEEKDAYS EST 201-444-0600 Direct Wire-In Photocontrols (120 - 480 Volts) Heavy-duty Die-cast Enclosure Vandal Proof Lumatrol® “T” Series Lumatrol® “T-30” Wire-In Photo Control - 3000 Watts Cast Aluminum Housing photocontrols - Designed for Designed for those applications which demand more those locations where high vandalism creates high load switching than standard 15 amp. series can maintenance. The heavy-duty cast aluminum housing handle. is 20 times more resistant to high-impact objects (i.e. rocks, bats or small projectiles) than plastic housing. Specifications As the controlling element of the total lighting pack- Housing: Lexan enclosure. age (fixture, lamp ballast) and the least costly compo- Photocell: Broad surface sensing element. nent, it is most important that the control continue to Turn-on: 1 to 3 foot-candles. External light level slide allows function under all adverse conditions. field adjustment between 3 to 10 foot-candles. Specifications Turn-on/ 1:3 Turn-off Ratio: Housing: Vandal proof die cast aluminum housing. Switch Type: Single-pole, single-throw. Contact position at night Photocell: Broad surface sensing element. normally closed. Turn-on: 1 to 3 foot-candles. External light level slide allows Time Delay: Minimum 15 seconds. field adjustment between 3 to 10 foot-candles. Temperature -40˚ to 170˚ F. 1:3 Turn-on/ Range: Turn-off Ratio: Power 1.1 watts average at 120 VAC. Single-pole, single-throw. Contact position at night Switch Type: Consumption: normally closed. Rated Life: 5,000 operations minimum at rated load. Time Delay: Minimum 15 seconds. Threaded Stem: 1/2 inch-14 thread, and fits 1/2 inch knock out. Temperature -40˚ to 170˚ F. Range: Dimensions: 3’’ high, 2’’ wide, 1-3/8’’ deep. Lead Wire: Moisture proof, color coded lead wire. Ordering Guideline Wire length: 6 inches. Model Voltage Rating 1/2 inch-14 thread, and fits 1/2 inch knock out. Threaded Stem: T-30 120 3000 VA Dimensions: 3’’ high, 2’’ wide, 1-3/8’’ deep. T-368 208-277 3000 VA Ordering Guideline T-30DV 105-285 3000 VA Model Voltage Rating T-15-AL 120 1800 VA All Precision photocontrols T-168-AL 208-277 1800 VA are 100% compatible with T-30-AL 120 3000 VA compact fluorescent lamps. T-368-AL 208-277 3000 VA 2 Direct Wire-In Photocontrols (120 - 480 Volts) “ET” A-105 Series “T” “ST” A-105W Series Series U.L. recognized component with standard wall plate Lumatrol® “T”, “ET” & “ST” Series Lumatrol® “A” Series Wire-In Wire-In Photocontrols Photocontrols Specifications Specifications Housing: Weatherproof Lexan® housing. Housing: Durable, high impact Lexan® housing, ultrasonically Photocell: Broad surface sensing element. welded for maximum strength. Nylon locknut provided. Compact in size, A-105 can be mounted directly within a Turn-on: 1 to 3 foot-candles. External light level slide allows field lighting fixture or in lighting standards that are 2 inches adjustment between 3 to 10 foot-candles. in diameter or larger. Turn-on/ 1:3 Photocell: Broad surface sensing element. Turn-off Ratio: Turn-on: 1 to 3 foot-candles. Switch Type: Single-pole, single-throw. Contact position at night 1:3 normally closed. Turn-on/ Turn-off Ratio: Time Delay: Minimum 15 seconds. Switch Type: Single-pole, single-throw. Contact position at night Temperature -40˚ to 158˚F. normally closed. Range: Time Delay: Minimum 15 seconds. Lead Wire: Moisture proof, color coded lead wire. -30˚ to 140˚ F. Wire length: 6 inches. Temperature Range: Threaded Stem: 1/2"-14 thread, and fits 1/2" knock out. Swivel T-Series (ST) is equipped with a swivel mount which allows Lead Wire: Color coded lead wire. Wire length: 15 inches. installer to swivel light sensitive element to the best Threaded 3/8 inch-18 thread; threaded stem 3/4 inches long. position for operation. Stem: Dimensions T Series: 2’’ high, 1-1/2’’ wide, 1’’ deep. Dimensions: 2” high, 1-1/4” wide, 3/4” deep (1-1/2” deep including ST Series: 2’’ high, 1-1/2’’ wide, 1’’ deep (body); 2’’ high, (stem). threaded stem). ET Series: 3½" high, 1" diameter Model Voltage Rating A-105* 120 1000 VA Ordering Guideline A-1068* 208-277 1000 VA Model Voltage Rating A-347† 347 1000 VA ST-15*, T-15* 120 1800 VA A-105W†** 120 1000 VA ST168, T-168 208-277 1800 VA A-1068W** 208-277 1000 VA ST-19**, T-19** 480 1800 VA ** Complete with gasketed metal wall plate (2¾" x 4½"), mounting screws, ST-347** 347 1800 VA and two nylon locknuts so that units will fit any standard outlet box. ET-15 120 1800 VA * UL Recognized & CSA Certified †CSA Certified only. ET-168 208-277 1800 VA Note: The body or housing of all "A" style models must be mounted in a ** Dimensions: 3” high, 2” wide, 1³⁄₈” deep. weather proof enclosure to assure protection from water damage. Only * ETL listed. threaded portion is weather proof. 3 For Direct Wire, Low Voltage Applications LCA SERIES LCS SERIES 24 VDC/VAC 24 VDC/VAC and 12VDC and 12VDC Lumatrol® Low Voltage Lumatrol® Low Voltage “Stem Mount” Photocontrols “Button Type” Photocontrols Specifically designed for a 12 volt DC, or 24 volt AC/DC Specifically designed for inside compatible light fixtures battery operated light source or low voltage control or in weatherproof enclosures 2” in diameter or larger. circuits. Rated at 70º C to operate in high tempera- tures near solar modules. Specifications Housing: Durable, high impact Lexan® housing, ultrasonically welded Specifications for maximum strength. Nylon locknut provided. Compact in Housing: Weatherproof Lexan® housing. size, LCA series can be mounted directly within a lighting fix- ture or in lighting standards that are 2'' in diameter or larger. Turn-on: 1 to 3 foot-candles. Turn-on: 1 to 3 foot-candles. Turn-on/ 1: 1.5 Turn-off Ratio: Turn-on/ 1:1.5 Switch Type: Single-pole, single-throw. Contact position at night Turn-off Ratio: normally closed. Switch Type: Single-pole, single-throw. Contact position at night normally Time Delay: 1-5 seconds. closed. 1-5 seconds. Threaded Stem: 1/2 inch-14 thread, and fits 1/2 inch knock out. Time Delay: Swivel Series is equipped with a swivel mount which Threaded Stem: 3/8 inch-18 thread; threaded stem 3/4 inches long. allows installer to swivel light sensitive element to Dimensions: 2” high, 1-1/8” wide, 1-3/4” deep (2” deep w/threaded stem). the best position for operation. 2’’ high, 1-1/2’’ wide, 1’’ deep. Dimensions : “LCA” Series Power Dissipation: 12-1/2 MA@ 12VDC Model Voltage Rated Load LCA-612D 12 VDC 10 AMP “LCS” Series LCA-624A 24 VAC 10 AMP Model Voltage Rated Load LCA-624D 24 VDC 10 AMP LCS-612D 12 VDC 10 AMP† LCA-612AW* 12 VDC 10 AMP LCS-624D 24 VDC 10 AMP† LCA-624AW* 24 VAC 10 AMP * Wall plate models. LCS-624A 24 VAC 10 AMP† (See bottom of page 3 for wall LCA-624DW* 24 VDC 10 AMP plate dimensions.) † Non-inductive. Photocontrol 24 VAC ORANGE LOW VOLTAGE RED + CONTROL PHOTOCONTROLS Lamp Load Load (black) (red) WIRING DIAGRAMS (white) POWER Neutral LOAD (white) 48, 24 & BLACK Line (black) – 12 VDC (white) (black) TYPICAL WIRING (DC) 4 Locking Type, Low Voltage Lighting Applications LCP SERIES + M2ANB-LV Locking Type Receptacle Model M2ANB-LV for all low voltage, locking type control applications. Comes with housing and receptacle (½" threaded stem). See page 7 for model M2A. M2ANB-LV Specifications Locking-type, polarized receptacle with 14'' 48 VDC, 24 VDC and 12 VDC 14 AWG color coded leads Leads: Red (+). Black (-) and Orange (Load). Low Voltage Locking Type Dimensions: 2⁵⁄₈" high (incl. ½" stem), diameter 2 ¾" Photocontrols Rated Load: 10 AMP Available in 48 VDC, 24VDC & 12 VDC Rated at 170˚ F to operate in high temperatures near solar models. DO NOT USE WITH AC RECEPTacLES! Twistlock format for easy replacement. Precision's low-voltage twistlock system is designed for low voltage DC use only! To avoid LCP Specifications mis-application use Precision's low-voltage Housing: UV stabilized high-impact polypropylene base, M2ANB-LV with orange "load" wire. Sensor: Sealed Silicon Sensor Turn-on: 1 to 3 foot-candles Turn-on/ 1:1.5 Turn-off Ratio: LCP Low Voltage Wiring Diagrams Switch Type: Single-pole, single-throw. Contact position at night normally closed. DIRECT WIREIN Time Delay: 1 to 5 seconds. PHOTO CONTROL OR LOCKING TYPE RECEPTICAL Temperature -40˚ to 170˚ F load Range: red orange (+) to be Power 10 MA switched Dissipation: Rated Life: 5,000 operations minimum at rated load black Rated Load: 10 AMP Surge Protection: MOV (Metal Oxide Varistor) (-) Dimensions: 3.07” diameter, 2.15” high. DC color codes: Red = Positive (+) Ordering Guideline Orange = Load Model Voltage Rated Load Black = Negative (-) LCP-48 48 VDC 10 AMP LCP-24 24 VDC 10 AMP LCP-12 12 VDC 10 AMP 5 Locking-Type Photocontrols (120 - 285 Volts) C US C US Locking-Type Photocontrols- Utility-Grade Electronic Series Delayed Response Thermal Series Built-in time delay prevents false cycling caused by 1 to 1.5 on/off ratio for maximum energy savings.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    12 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us