Symbol Overview F25 001 HWR
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Electrical Components
ELECTRICAL COMPONENTS Magnetic Starters Coil HP @ 115V HP @ 230V HP @ 230V HP @ 380V HP @ 460V Part No. Model No. Frame Voltage 1 PH 1 PH 3 PH 3 PH 3 PH 6-4003 CH CE15BNS3TB B 24V .05 1.0 2.0 5.0 5.0 6-4000 CH CE15BNS3AB B 120V .05 1.0 2.0 5.0 5.0 6-4001 CH CE15BNS3BB B 240V .05 1.0 2.0 5.0 5.0 6-4002 CH CE15BNS3CB B 480V .05 1.0 2.0 5.0 5.0 6-4006 CH CE15CNS3TB C 24V .05 2.0 3.0 5.0 7.5 6-4004 CH CE15CNS3AB C 120V .05 2.0 3.0 5.0 7.5 6-4005 CH CE15CNS3BB C 240V .05 2.0 3.0 5.0 7.5 • Cutler-Hammer quality 6-4007 CH CE15DNS3AB D 120V 1.0 3.0 5.0 10.0 10.0 • Highest HP rating 6-4008 CH CE15DNS3BB D 240V 1.0 3.0 5.0 10.0 10.0 in a compact space 6-4009 CH CE15DNS3CB D 480V 1.0 3.0 5.0 10.0 10.0 saving design 6-4024 CH CE15DNS3DB D 600V 1.0 3.0 5.0 10.0 10.0 • Long-life twin break, silver cadmium oxide 6-4012 CH CE15ENS3TB E 24V 2.0 3.0 7.5 10.0 15.0 contacts provide superior 6-4010 CH CE15ENS3AB E 120V 2.0 3.0 7.5 10.0 15.0 resistance to welding 6-4011 CH CE15ENS3BB E 240V 2.0 3.0 7.5 10.0 15.0 and arc erosion 6-4015 CH CE15FNS3TB F 24V 2.0 5.0 10.0 15.0 20.0 • Din rail mounting 6-4013 CH CE15FNS3AB F 120V 2.0 5.0 10.0 15.0 20.0 6-4014 CH CE15FNS3BB F 240V 2.0 5.0 10.0 15.0 20.0 6-4016 CH CE15FNS3HB F 277V 2.0 5.0 10.0 15.0 20.0 6-4017 CH CE15FNS3CB F 480V 2.0 5.0 10.0 15.0 20.0 6-4020 CH CE15HNS3TB-09 H 24V 3.0 7.5 15.0 25.0 30.0 6-4018 CH CE15HNS3AB-09 H 120V 3.0 7.5 15.0 25.0 30.0 6-4019 CH CE15HNS3BB-09 H 240V 3.0 7.5 15.0 25.0 30.0 6-4021 CH CE15JNS3AB-09 J 120V 5.0 10.0 20.0 30.0 40.0 6-4022 CH CE15JNS3BB-09 J 240V 5.0 10.0 20.0 30.0 40.0 Overload Relays Push Button & Contact Blocks • Cutler-Hammer quality • Direct heated bimetal elements • Adjustable trip current, overload trip indication • Cutler-Hammer quality • Manual/automatic reset • Heavy-duty • Din rail mounting • Water tight/oil tight Part No. -
Helios Standard Range Catalogue
Measure. Control. Regulate. Comfortably controlled and energy-saving. MEASURE CONTROL REGULATE Controlling ventilation and Changes in room occu- Complete system solutions The extensive MSR range air conditioning systems pancy, deteriorations in bring the maximum possible from Helios provides the in accordance with the quality of air at different security for the user and full ideal solution for any appli- changing requirements times, fluctuating tempera- guarantee by Helios. cation and simultaneously and conditions is a must tures, day and night set- Furthermore, a lot of time meets all requirements in for comfortable, energy tings, etc. call for corre- can be saved during plan- relation to energy saving efficient ventilation. sponding adjustments. ning, installation and opera- and noise reduction. Helios offers regulation, tion if the control and regu- control and switch devices lation devices are perfectly for all functions, which are adapted to the fans and tailored to the fans. their functions. Problems are solved before they emerge. 525 Measure Control · Regulate Control. Regulate. Optimise. Task Helios controller solution Page Manual control of air I Manual speed controller flow volume – Without motor protection – 10 V, 24 V DC – Potentiometer for EC fans PU / PA, SU / SA 541 – 230 V~ – Electronic, flush / surface mounted ES, BSX 531 – 230 V~ – Transformer, surface mounted TSW, TSSW 532 – 400 V 3~ – Transformer, surface mounted TSD, TSSD 533 – 230 V~ – Transformer, electronic, surface mounted ETW 535 – With built-in motor full protection for connection to thermal contacts – 230 V~ / 400 V 3~ – Transformer, surface mounted MWS / RDS 532 f. – 400 V 3~ – Electronic, surface mounted ESD 535 – 400 V 3~ – Frequency inverter FU 536 f. -
Basic Electricity
BASIC ELECTRICITY STUDY COURSE for Home Appliances HOW TO READ: • WIRING DIAGRAM SYMBOLS • TERMINAL CODES • WIRING DIAGRAMS CABINET GROUND BK W STARTER BALLAST S 1 FLUORESCENT LAMP Module 2 LIT 787740 Rev. C For More Appliance Troubleshooting, Repair Help, & DIY Videos Visit ApplianceAssistant.com Note: This Page was not included by Whirlpool Corporation ApplianceAssistant.com is not affiliated Whirlpool Corporation Whirlpool Corporation in no way endorses ApplianceAssistant.com WHIRLPOOL CORPORATION does not assume any responsibility or any liability in connection with the use of this manual. © 1989, 1993, 2000 WHIRLPOOL CORPORATION All rights reserved. No portion of this book may be reproduced in any form without written permission from WHIRLPOOL CORPORATION. ® The trademarks WHIRLPOOL , , , and FSP are registered trademarks of Whirlpool Corporation. INTRODUCTION The material presented in this module is intended to provide you with an understanding of the fundamentals of electricity as applied to major appliances. Major appliances have become more sophisticated, taking them out of the screwdriver and pliers category. Their electrical circuits include several different types of automatic controls, switches, heaters, valves, etc.. Semiconductors, solid-state controls, and other components usually associated with radio and television electronic circuits, are being engineered into automatic washers, dryers, dishwashers, and refrigerators. The appliance technician is emerging into a professional status of his own. He must prepare himself now to be able to perform his duties today as well as to retain his professionalism in the future. No longer is on-the-job training sufficient to prepare technicians for the complicated procedures required for todays sophisticated appliances. This training can best be obtained through organized classroom study and application. -
Installation Instructions
50LC Single Package Rooftop Cooling Only with Puronr (R---410A) Refrigerant Sizes: 04, 05, 06 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS SAFETY CONSIDERATIONS.................... 2 All Units................................ 19 Convenience Outlets....................... 20 INSTALLATION............................... 6 HACR.................................. 21 Jobsite Survey................................ 6 Factory--Option Thru--Base Connections...... 21 Step 1 --Plan for Unit Location.................. 6 Units without Thru--Base Connections......... 22 Roof Mount............................... 6 Field Control Wiring....................... 22 Step 2 -- Plan for Sequence of Unit Installation...... 6 Thermostat............................... 22 Curb--Mount Installation..................... 6 Unit without Thru--Base Connection Kit....... 22 Pad--Mount Installation...................... 7 Heat Anticipator Settings................... 23 Frame--Mount Installation.................... 7 Electric Heaters............................ 23 Step 3 --Inspect Unit........................... 7 Single Point Boxes & Supplementary Fuses.... 24 Step 4 -- Provide Unit Support................... 7 Single Point Boxes without Fuses............ 24 Roof Curb Mount.......................... 7 Low--Voltage Control Connections............ 24 Slab Mount (Horizontal Units Only)........... 7 Humidi--MiZerR Control Connections.......... 25 Alternate Unit Support (In Lieu of Curb or Slab Mount)............. -
Operator and Place This Installation Manual in an Accessible Place Near the Operator
Installation & Instruction Manual OOppeerraa--HH OOppeerraa--JJ Note: Read this manual carefully before installing the operator and place this installation manual in an accessible place near the operator. For future reference record: Model # Date Wiring Diagram # Model # Project No. Project Name Door No. # 2 IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH, READ AND FOLLOW ALL INSTRUCTIONS. 1. Never allow children to operate or play with or near door. 2. Check to see that the operator is correct for the type, size of door and frequency of use per the operator specifications. 3. If the door system is near a residential area, or pedestrian traffic is expected near the door system, additional equipment such as electric reversing edges, photocells, or similar devices must be installed as part of the system to prevent entrapment. 4. Reversing devices appropriate to the application must be installed as part of the system. 5. Outdoor or easily accessible controls must be of the security type to prevent unauthorized use of the system. 6. Place controls far enough from the door so that a user cannot touch the door when operating the controls. 7. Controls should be placed so the user has full view of the door when operating. 8. Always keep moving door in sight and away from people or vehicles until it is completely opened or closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 9. If a person is trapped under the door, push the "OPEN" control button. 10. Do not overtighten a clutch to compensate for a damaged door. -
Installation Manual Economizer Damper Linkage Tight Gas Heat Vent Hood Installed All Field Wiring (Power and Control) Complete
R-410A ZR SERIES 3 - 5 Ton 60 Hertz TABLE OF CONTENTS General . 2 Power Exhaust . 30 Installation . 5 Operation. 30 Installation Safety Information . 5 Checking Supply Air CFM . 41 Limitations . 5 Operation . 42 Location . 7 Sequence Of Operations Overview . 42 Rigging And Handling . 7 Cooling Sequence Of Operation . 42 Ductwork . 12 Reheat Mode Sequence Of Operation . 42 Condensate Drain . 12 Cooling Operation Errors . 43 Compressors . 12 Electric Heating Sequence Of Operations. 44 Filters . 13 Electric Heat Operation Errors . 44 Power And Control Wiring . 13 Gas Heating Sequence Of Operations . 45 Typical Field Power and Control Wiring . 15 Gas Heat Operation Errors . 46 Typical Power Wiring . 15 Error Messages . 47 Typical Reheat Control Wiring (Simplicity S E ZR036-060). 15 Resets . 47 Optional Electric Heat . 26 Heat Anticipator Setpoints . 47 Options/Accessories . 29 Start-up (Cooling) . 47 Economizer And Power Exhaust Set Point Adjustments. 29 Start-up (Gas Heat) . 47 Economizer Sequences. 29 Checking Gas Input . 49 Dry Bulb Changeover . 29 Charging The Unit . 50 Single Enthalpy Changeover . 29 Simplicity SE Control Board Navigation Components . 52 Dual Enthalpy Changeover . 30 Simplicity™ SE (Smart Equipment) Firmware Version 3. Basic Auto . 30 Unit Control Board Navigation Examples: . 53 Free Cooling Operation . 30 Start-Up Sheet . 61 LIST OF TABLES 1 ZR036-060 Unit Limitations . 6 16 Belt Drive RPM Selection . 40 2 Weights and Dimensions . 8 17 Indoor Blower Specifications (Belt Drive) . 40 3 ZR036-060 Unit Accessory Weights . 8 18 Power Exhaust Specifications . 41 4 ZR036-060 Unit Clearances . 10 19 Additional Static Resistance . 42 5 ZR036-060 Utilities Entry . 11 20 Electric Heat Limit Setting . -
6.2. Certification Mark 6.3. Products Requiring
6. CCC Approved Equipment 6.1. What is CCC? In 1993, CCIB (China Commodity Inspection Bureau) has introduced CCIB CCEE Safety Certification (CCIB Certification) for imported electric and electronic products under the control of SAIQ (The State + Administration for Entry-Exit Inspection and Quarantine of P.R. of China). In 1994, CCEE (China Commission for Conformity Certification of Electrical Equipment) has introduced Safety Certification (CCEE CCC Certification) for electric and electronic products sold in China, under the control of CSBTS (China State Bureau of Quality and Technical Supervision). In such situation, the government of China took the opportunity of joining in WTO (World Trade Organization) in November 2001, and two certification (CCEE and CCIB) merged into a single certification. CCC (China Compulsory Certification) was announced as a new compulsory product safety certification. CCC has enforced on May 1, 2002 and effective on August 1, 2003. 6.2. Certification Mark One of the following 4 marks shall be displayed on products or packages and instruction manuals. S EMC S&E F S: Safety EMC: EMC S&E: Safety and EMC F: Fire-fighting Products 6.3. Products Requiring CCC Products requiring Certification should be the following 19 items, 132 categories listed in the “First Catalogue of Products Subjects to Compulsory Certification” published as “Joint Announcement No. 2001-33 by AQSIQ*1 and CNCA*2”. *1: State General Administration of the People’s Republic of China for Quality Supervision and Inspection and Quarantine *2: Certification -
Sg Series Gas Convection Ovens
SERVICE MANUAL SG SERIES GAS CONVECTION OVENS MODELS SG4 SG6 STACKED SG44 MODELS SG66 - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified. This manual is not intended to be all encompassing. If you have not attended a Vulcan Service School for this product, you should read, in its entirety, the repair procedure you wish to perform to determine if you have the necessary tools, instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools, instruments and skills should be performed by a trained Vulcan Service Technician. The reproduction, transfer, sale or other use of this Manual, without the express written consent of Vulcan, is prohibited. This manual has been provided to you by ITW Food Equipment Group LLC ("ITW FEG") without charge and remains the property of ITW FEG, and by accepting this manual you agree that you will return it to ITW FEG promptly upon its request for such return at any time in the future. A product of Vulcan-Hart 3600 North Point Blvd Baltimore, MD 21222 F45525 Rev. B (1118) SG SERIES GAS CONVECTION OVENS TABLE OF CONTENTS SERVICE UPDATES ....................................................................................... 4 SERVICE UPDATES - SG .............................................................................. 4 GENERAL .................................................................................................. 5 INTRODUCTION ...................................................................................... -
KRAUS & NAIMER BLUE LINE Push Buttons and Pilot Lights
KRAUS & NAIMER BLUE LINE Push Buttons and Pilot Lights Web-site: http://www.krausnaimer.com I S O 9001 Programs Push buttons and pilot lights by Kraus & Naimer represent an ideal combination of functional security and economical efficiency in a modular design. Push Buttons Cam Switches • Non-illuminated or illuminated • ON/OFF switches and double-throw switches • Flush, extended or with extended front ring • Protection IP65 • Momentary or latched (for converting into spring return • For further cam switches, refer to Catalogue 120 function) Pilot Lights Enclosures • Standard units flush or conical • Plastic yellow or grey • Solid pilot lights (direct wire) • With 1, 2, 3, 4 or 6 options Double-Push Buttons Legend Options • Non-illuminated or illuminated • Front plates and color caps • Legend inserts Emergency Stop Push Buttons Accessories • Fool-proof • A wide range of accessories are available, e.g. protection shrouds • Non-illuminated or illuminated and protection caps • Optional mounting in enclosure Potentiometer Environmentally Compatible Materials • Incl. resistor • Cadmium and asbestos-free • recyclable Reset Push Button Selection • Incl. reset rod • Complete units • Pre-assembled front elements • Individual components Rotary Switches • Non-illuminated or illuminated • Without and with key • Momentary (for converting into spring return function) Contact Blocks and LED Pilot Light Assemblies Contact blocks • Finger-proof and open terminals (IP 20) LED Pilot Light • Captive mounting screws Assemblies Coupling • Low overall depth, -
Measure. Control. Regulate
Measure. Control. Regulate. Comfortably controlled and energy-saving. MEASURE CONTROL REGULATE Controlling ventilation and Changes in room occu- Complete system solutions The extensive MSR range air conditioning systems pancy, deteriorations in bring the maximum possible from Helios provides the in accordance with the quality of air at different security for the user and full ideal solution for any appli- changing requirements times, fluctuating tempera- guarantee by Helios. cation and simultaneously and conditions is a must tures, day and night set- Furthermore, a lot of time meets all requirements in for comfortable, energy tings, etc. call for corre- can be saved during plan- relation to energy saving efficient ventilation. sponding adjustments. ning, installation and opera- and noise reduction. Helios offers regulation, tion if the control and regu- control and switch devices lation devices are perfectly for all functions, which are adapted to the fans and tailored to the fans. their functions. Problems are solved before they emerge. 525 Measure Control · Regulate Control. Regulate. Optimise. Task Helios controller solution Page Manual control of air I Manual speed controller flow volume – Without motor protection – 10 V, 24 V DC – Potentiometer for EC fans PU / PA, SU / SA 541 – 230 V~ – Electronic, flush / surface mounted ES, BSX 531 – 230 V~ – Transformer, surface mounted TSW, TSSW 532 – 400 V 3~ – Transformer, surface mounted TSD, TSSD 533 – 230 V~ – Transformer, electronic, surface mounted ETW 535 – With built-in motor full protection for connection to thermal contacts – 230 V~ / 400 V 3~ – Transformer, surface mounted MWS / RDS 532 f. – 400 V 3~ – Electronic, surface mounted ESD 535 – 400 V 3~ – Frequency inverter FU 536 f. -
Installation & Instruction Manual
InstallationInstallation && InstructionInstruction ManualManual Commercial & Industrial Heavy Duty Jackshaft Operators (For sectional doors, rolling doors and grilles) Opera-H Opera-J Opera-HJ Opera-SH (OPH) (OPJ) (OHJ) (OSH) Electronic Control (BOARD 070E) READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS. GIVE TO END-USER. Serial # Model # Wiring Diagram # Project #/Name Door #/Name For technical support, please call 1-800-361-2260 or visit www.manaras.com for more information 2 TABLE OF CONTENTS Installation Instructions............................................................................................................................................... 3 1 General Specifications and Dimensions (OPH / OPJ / OHJ).........................................................................................................................4 2 General Specifications and Dimensions (OSH)..............................................................................................................................................5 3 Door & Operator Hardware...............................................................................................................................................................................6 3.1 Delivery of Operator..................................................................................................................................................................................6 3.2 Hardware Supplied....................................................................................................................................................................................6 -
Ctg Product List
Product List Crestwood Technology Group 914.779.3500 | [email protected] CTGNOW.com Any part, any platform, we can help. Here is a quick overview of parts and material we provide. Expendables Rotables ATA Chapters Actives INTEGRATED CIRCUITS Batteries Actuators ATA Chapters AC to DC Switching Converters Bonding Leads Air Regulators Accessory Gearboxes Analog Cable Assemblies APUs Air Analog – Digital Converter Connectors Ballast Units Air Conditioning Angular and linear Position Sensors Contacts Boroscopes Airborn Auxiliary Power Appdlication Processor and SOC Fans Cargo Liners Auto Flight Audio Processor Fasteners Cargo Nets Central Maintenance System Controllers Filters Cargo Panels Communications Converters Hardware Cockpit Avionics Doors CPLD Inductors Composites Electrical Power CPUs Lamps/LEDs Compressors Engine Controls Current miters Placards/Decals Disks Engine Exhaust Current Mode PWM Controller Relays Displays Engine Fuel and Control Current Sensor Tape Doors Engine Indicating DC to DC Controller Drive-Shafts Engine Oil Digital Elevator Assemblies Equipment / Furnishings Consumables Digital – Analog Converter Engine Components Fire Protection D-RAM Engines Flight Controls Adhesives, Tapes & Sealants DSP Evacuation Slides and Life Fuel Solvents EE-PROM Rafts Fuselage Composite Materials EPROM Fire Extinguishers Hardware Shop Supplies FPGA Flap Carriages Helicopter Vibration Oils, Greases & Lubricants Hall Effect Sensor Fuel Pumps Hydraulic Power Paints & Coatings Hot Swap Controller Gear Box Ice and Rain Protection Industrial