Sg Series Gas Convection Ovens

Total Page:16

File Type:pdf, Size:1020Kb

Sg Series Gas Convection Ovens SERVICE MANUAL SG SERIES GAS CONVECTION OVENS MODELS SG4 SG6 STACKED SG44 MODELS SG66 - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified. This manual is not intended to be all encompassing. If you have not attended a Vulcan Service School for this product, you should read, in its entirety, the repair procedure you wish to perform to determine if you have the necessary tools, instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools, instruments and skills should be performed by a trained Vulcan Service Technician. The reproduction, transfer, sale or other use of this Manual, without the express written consent of Vulcan, is prohibited. This manual has been provided to you by ITW Food Equipment Group LLC ("ITW FEG") without charge and remains the property of ITW FEG, and by accepting this manual you agree that you will return it to ITW FEG promptly upon its request for such return at any time in the future. A product of Vulcan-Hart 3600 North Point Blvd Baltimore, MD 21222 F45525 Rev. B (1118) SG SERIES GAS CONVECTION OVENS TABLE OF CONTENTS SERVICE UPDATES ....................................................................................... 4 SERVICE UPDATES - SG .............................................................................. 4 GENERAL .................................................................................................. 5 INTRODUCTION ....................................................................................... 5 INSTALLATION ........................................................................................ 5 OPERATION ........................................................................................... 5 CLEANING ............................................................................................. 5 LUBRICATION ......................................................................................... 5 SPECIFICATIONS ...................................................................................... 5 TOOLS ................................................................................................. 5 REMOVAL AND REPLACEMENT OF PARTS ............................................................... 6 COVERS AND PANELS ................................................................................ 6 TOP FRONT COVER ............................................................................... 6 BOTTOM FRONT COVER .......................................................................... 6 CONTROL PANEL ................................................................................. 6 RIGHT SIDE PANEL ................................................................................ 6 CONTROL PANEL COMPONENTS ..................................................................... 7 COMPONENT PANEL COMPONENTS ................................................................. 7 TEMPERATURE PROBE ............................................................................... 8 GAS BURNER ......................................................................................... 9 GAS ORIFICE .......................................................................................... 9 GAS SOLENOID VALVE .............................................................................. 10 IGNITION CONTROL MODULE ....................................................................... 11 SPARK IGNITER AND FLAME SENSE ................................................................ 12 BLOWER AND MOTOR ENDING AT PRODUCTION DATE OF 3/18/2018 .............................. 13 BLOWER AND MOTOR STARTING AT PRODUCTION DATE OF 3/19/2018 ........................... 15 OVEN DOORS AND BEARINGS (INDEPENDENT DOORS) ENDING AT PRODUCTION DATE OF 1/21/2018 ............................................................... 16 OVEN DOORS (INDEPENDENT DOORS) STARTING AT PRODUCTION DATE OF 1/22/2018 ......... 17 ROLLER LATCH ASSEMBLY (INDEPENDENT DOORS) ............................................... 18 DOOR WINDOW ...................................................................................... 18 DOOR SWITCH ....................................................................................... 19 HIGH LIMIT THERMOSTAT ........................................................................... 19 INTERIOR LIGHTS .................................................................................... 20 COOLING FAN ........................................................................................ 20 INTERIOR LIGHTS (REAR MOUNTED, ROUND) ...................................................... 21 INTERIOR LIGHTS (SIDE MOUNTED, SQUARE) ...................................................... 21 DOOR ADJUSTMENT ................................................................................. 23 SERVICE PRODCEDURES AND ADJUSTMENTS ......................................................... 25 SOLID STATE TEMPERATURE CONTROL CALIBRATION ............................................ 25 SOLID STATE TEMPERATURE CONTROL TEST ..................................................... 26 TEMPERATURE PROBE TEST ....................................................................... 27 GAS VALVE PRESSURE CHECK ..................................................................... 27 VERIFICATION OF SPARK AT IGNITOR .............................................................. 28 DOOR SWITCH ADJUSTMENT ....................................................................... 29 BLOWER ADJUSTMENT .............................................................................. 29 DOOR ADJUSTMENT ................................................................................. 30 DOOR STRIKE ADJUSTMENT (INDEPENDENT DOORS) ............................................. 31 FLAME SENSE CURRENT TEST ...................................................................... 31 ELECTRICAL OPERATION ................................................................................ 34 COMPONENT LOCATION ............................................................................. 34 COMPONENT FUNCTION ............................................................................ 37 SEQUENCE OF OPERATION ......................................................................... 38 F45525 Rev. B (1118) Page 2 of 46 SG SERIES GAS CONVECTION OVENS NORMAL CYCLE ................................................................................. 38 COOL DOWN CYCLE (SOLID STATE TEMPERATURE CONTROL) ................................ 40 SCHEMATICS ........................................................................................ 41 WIRING DIAGRAM .................................................................................... 42 TROUBLESHOOTING ..................................................................................... 44 ALL MODELS ......................................................................................... 44 IGNITION MODULE DIAGNOSTICS ................................................................... 45 © VULCAN 2018 Page 3 of 46 F45525 Rev. B (1118) SG SERIES GAS CONVECTION OVENS - SERVICE UPDATES SERVICE UPDATES SERVICE UPDATES - SG October 2018 • FLAME SENSE CURRENT TEST • OVEN DOORS (INDEPENDENT DOORS) Starting at Production Date of 1/22/2018 • INTERIOR LIGHTS (Rear Mounted, Round) • INTERIOR LIGHTS (Side Mounted, Square) • DOOR ADJUSTMENT • COMPONENT LOCATION • SCHEMATICS • WIRING DIAGRAM • IGNITION MODULE DIAGNOSTICS F45525 Rev. B (1118) Page 4 of 46 SG SERIES GAS CONVECTION OVENS - GENERAL GENERAL INTRODUCTION Procedures in this manual will apply to all models unless specified. Pictures and illustrations can be of any model unless the picture or illustration needs to be model specific. MODELS FEATURES OPTIONS MODEL CAVITY TEMPERTURE COOK BLOWER DOORS (50/50) CASTERS DEPTH CONTROL TIMER 208/240/60/1 SG4 26.5" Solid State Independent 1-Hour Dial Optional Optional SG6 30.5" Solid State Independent 1-Hour Dial Optional Optional INSTALLATION Natural - Recommend (in. W.C.) 8.0, Min 6.0 Propane - Recommend (in. W.C.) 11.0, Min 11.0 Refer to the Installation and Operation Manual for Maximum 14.0 in. W.C. (Nat. or Prop.) detailed installation instructions on single or stacked ovens. TOOLS OPERATION Standard • Standard set of hand tools Refer to the Installation and Operation Manual for specific operating instructions. • VOM with ability to measure micro amp current VOM with minimum of NFPA-70E CAT III 600V, CLEANING UL/CSA/TUV listed. Sensitivity of at least 20,000 ohms per volt. Meter leads must also be rated at Refer to the Installation and Operation Manual for CAT III 600V. specific cleaning instructions. • Gear Puller to remove blower LUBRICATION Special • Temperature tester (thermocouple type) • Cavity blower motor has sealed bearings and • Manometer requires no additional lubrication. • Huskey™ TF-1000 grease or equivalent high temperature Teflon grease. SPECIFICATIONS Electrical Voltage - 120/60/1 Amps - 8.0 Amps Input BTU Rating Natural Gas - 60,000 BTU input at 5.0 in. W.C. Propane Gas - 60,000 BTU input at 10.0 in. W.C. Gas Line Pressures Page 5 of 46 F45525 Rev. B (1118) SG SERIES GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS REMOVAL AND REPLACEMENT OF PARTS COVERS AND PANELS Control Panel 1. Remove three (3) screws on the right side which secure the control panel then pull the panel away from the oven. Disconnect the electrical power to the machine
Recommended publications
  • W Series Impulse Voltage Test System
    W SERIES IMPULSE VOLTAGE TEST SYSTEM Impulse Voltage Test System is used to generate impulse APPLICATION voltages from 100 KV to 2400 KV simulating lightning strokes The basic system is used to test any high voltage and switching surges with energies up to 240 KJ. equipment like The KVTEK make impulse voltage test systems are modular in ØPower Transformers construction, flexible and cover testing applications according to IEC, ANSI/IEEE and other national standards. ØDistribution Transformers The basic system can be upgraded in various ways to allow ØCable (Type Tests) optimizing the impulse test system for tests on different high ØSurge Arresters (impulse current tests) voltage equipments. ØMotor / Generators The system operation is user friendly and incorporates all the ØInsulators necessary features of Impulse Voltage Test. ØBushings ØGIS ØInstrument Transformers ØResearch & Development and Universities FEATURES ØLow internal inductance ØEasy and quick reconfiguration to suit different testing needs ØUser friendly operation through computer and microprocessor controlled hardware. ØEquipped with resistors for performing lightening full, lightening chopped and switching impulse tests on wide range of loads. ØAutomatic grounding device and security grounding system (available as an option). ØAlarm annunciation to display all fault conditions. ØFiltered clear air constantly supplied through the sphere gaps while the system is running. ØReliable and fail safe triggering circuitry. KVTEK POWER SYSTEMS PRIVATE LIMITED STRUCTURE CHARACTERISTICS CHARGING RECTIFIER ØAll the coupling sphere gaps are mounted in an insulated D100-0.05 (100 kV, 50 mA) OR D100-0.15 DC (100 kV, 150 mA) tube and every level of sphere gaps is equipped with spark Charging Power Supply comprises of: observation panel.
    [Show full text]
  • Installation Instructions to Ensure Proper Compres Installing Units with Any of the Optional Accessories Sor and Blower Operation
    INSTALLATION Litho U.S.A. 2003 INSTRUCTIONS LGC090S, LCC090S (7.5 Ton) WARNING LGA090H, LCA090H (7.5 Ton) Improper installation, adjustment, alteration, ser (8.5 Ton) vice or maintenance can cause property damage, LGA102H, LCA102H personal injury or loss of life. Installation and ser vice must be performed by a qualified installer, serĆ LGC102S, LCC102S (8.5 Ton) vice agency or the gas supplier LGA120H, LCA120H (10 Ton) Table Of Contents LGC120S, LCC120S (10 Ton) Dimensions. 1 LGC150S, LCC150S (12.5 Ton) Parts Arrangements. 2 L SERIES PACKAGED UNITS Shipping and Packing List. 3 504,785M General. 3 6/2003 Supersedes 504,563M Requirements. 3 Unit Support. 3 Electrical Connections. 7 Duct Connections. 4 Blower Operation and Adjustments. 9 Rigging Unit For Lifting. 4 Cooling Start−Up. 13 Condensate Drains. 4 Gas Heat Start−Up. 17 Gas Piping. 5 Heating Operation and Adjustments. 18 Pressure Test Gas Piping. 5 Electric Heat Start−Up. 19 High Altitude Derate. 6 Humiditrol® Start−Up and Operation. 20 Factory−Installed Options. 6 Service. 22 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE LCA SHOWN 06/03 504,785M *2P0603* *P504785M* LGA/LGC/LCA/LCC090, 102, 120, & 150 DIMENSIONS − LGA/LGC HEAT SECTION SHOWN *Reheat coils are factory−installed in Humiditrol units only. OPTIONAL OUTDOOR CONDENSER COIL AIR HOOD INTAKE AIR CONDENSER (Factory or COIL FAN (2) Field Installed) AA4 (102) 4 (102) BB 28 28 (711) (711) BOTTOM 51/2 20 61/4 20 SUPPLY AIR (140) (508) (159) (508) OPENING CONDENSER EVAPORATOR COIL COIL EE INTAKE BOTTOM AIR RETURN AIR CENTER BLOWER
    [Show full text]
  • FINDER Relays 7P Series
    7P Series - Surge Protection Device (SPD) Features 7P.21.8.275.1020 7P.22.8.275.1020 SPD Type 2 Surge arrester range - single phase systems • Surge arrester suitable for 230V system/ applications • Protects equipment against overvoltage caused by lightning strikes or switching transients 7P.21.8.275.1020 Varistor protection L - N 7P.22.8.275.1020 Varistor protection L - N + spark-gap protection N - PE • SPD Type 2 (1 varistor + 1 spark-gap) • SPD Type 2 (1 varistor) Spark-gap protection N - PE avoids earth • Combination of replaceable varistor and • Replaceable varistor module leakage current encapsulated spark gap modules • Visual and remote signalling of varistor status • Visual indication of Varistor status - • Visual and remote signalling of varistor status Healthy/Replace • Remote signalling contact of Varistor status Connector (07P.01) included • Replaceable modules • Complies with EN 61643-11 07P.01 07P.01 • 35 mm rail (EN 60715) mounting 12 11 14 12 11 14 7P.21 / 7P.22 Screw terminal L / N () L PE (L / N) N For outline drawing see page 6 SPD specification L-N N-PE Nominal voltage UN 230 V AC 230 V AC — Maximum continuous operating voltage UC 275 V AC / 350 V DC 275 V AC / 350 V DC 255 V AC Nominal discharge current (8/20 μs) In 20 kA 20 kA 20 kA Maximum discharge current (8/20 μs) Imax 40 kA 40 kA 40 kA Voltage protection level at 5kA UP5 0.9 kV 0.9 kV — Voltage protection level at In UP 1.2 kV 1.2 kV 1.5 kV Response time tA 25 ns 25 ns 100 ns Short-circuit proof at maximum overcurrent protection 35 kArms 35 kArms — Maximum overcurrent
    [Show full text]
  • The Basics of Surge Protection the Basics of Surge
    The basics of surge protection From the generation of surge voltages right through to a comprehensive protection concept In dialog with customers and partners worldwide Phoenix Contact is a global market leader in the field of electrical engineering, electronics, and automation. Founded in 1923, the family-owned company now employs around 14,000 people worldwide. A sales network with over 50 sales subsidiaries and 30 additional global sales partners guarantees customer proximity directly on site, anywhere in the world. Our range of services consists of products associated with a wide variety of electrotechnical applications. This includes numerous connection technologies for device manufacturers and machine building, components for modern control cabinets, and tailor-made solutions for many applications and industries, such as the automotive industry, wind energy, solar energy, the process industry or applications in the field Iceland Finland Norway Sweden Estonia Latvia of water supply, power transmission and Denmark Lithuania Ireland Belarus Netherlands Poland United Kingdom Blomberg, Germany Russia Canada Belgium distribution, and the transportation Luxembourg Czech Republic France Austria Slovakia Ukraine Kazakhstan Switzerland Hungary Slovenia Croatia Romania South Korea USA Bosnia and Serbia Spain Italy Herzegovina infrastructure. Kosovo Bulgaria Georgia Japan Montenegro Portugal Azerbaijan Macedonia Turkey China Greece Tunisia Lebanon Iraq Morocco Cyprus Pakistan Taiwan Israel Kuwait Bangladesh Mexico Algeria Jordan Bahrain India
    [Show full text]
  • Protection Characteristics of Spark Gaps
    fz <?rz>7orz> /fur-- *9- Protection characteristics of spark gaps Marja-Leena Pykala Veikko Palva 27 deceived ' ccq 2315 S3 OSTl Report Helsinki University of Technology High Voltage Institute Espoo, Finland 1997 DISCLAIMER Portions of this document may be illegible electronic image products. Images are produced from the best available original document. Report TWH ; Helsinki University of Technology High Voltage Institute ^*gh Voltage Itvs^ Protection characteristics of spark gaps Marja-Leena Pykala Veikko Palva ISSN 1237-895X ISBN 951-22-3438-6 January 27, 1997 Espoo, Finland 2 (24 ) Preface The High Voltage Institute of Helsinki University of Technology (HUT) has operated as the National Standards Laboratory of High Voltage Measurements since October 1995. Research is largely concentrated on high voltage measurement and metrology. This project concentrated on practical issues: distribution transformers and protective spark gaps. The project was supervised by the following expert group: Jarmo Elovaara from IVO Power Engineering Oy, Juha Sotikov from Finnish Electricity Association and Esa Virtanen from ABB Transmit Oy as well as Martti Aro, Matti Karttunen and Veikko Palva from Helsinki University of Technology. Abstract Distribution transformers in rural networks have to cope with transient overvoltages, even with those caused by the direct lightning strokes on the lines. In Finland, the 24 kV network conditions, such as wooden pole lines, high soil resistivity and isolated neutral network, lead into fast transient overvoltages. The distribution transformers (< 200 kVA) have been protected and a major part is still protected using protective spark gaps. The protection characteristics of different spark gap types were studied widely using improved measuring techniques.
    [Show full text]
  • Residual Resistance Simulation of an Air Spark Gap Switch
    Residual resistance simulation of an air spark gap switch. V. V. Tikhomirov, S.E. Siahlo∗ February 27, 2015 Research Institute for Nuclear Problems, Belarusian State University, Bobruiskaya 11, 220030 Minsk, Belarus Abstract The numerical simulation of an air spark gap has been carried within two theoretical models. The kinetic one [1] allowed us to calculate time dependencies for the residual resistance (0.2 - 0.4 Ohm for our selection of a circuit parameters), the spark gap channel width, the electron number density, the mobility, the conductivity, the ionization degree, the magnetic field in the discharge channel, the channel inductance and the electron drift velocity. Simulating a real circuit and taking into account a spark gap residual resistance demonstrates good agreement of both models with the experimental data, while that without taking into account this resistance overestimates the maximal current in the circuit by approximately 5%. 1 Introduction The high-voltage spark gap switches are essential elements of the circuits containing magneto- cumulative generators, capacitive and inductive energy storages, electro-explosive circuit break- ers etc. Very frequently spark gaps affect sufficiently the operation of the circuits and one cannot satisfactorily describe main elements functioning in the absence of a quantitative model of the processes occurring in the spark gaps. This article is devoted to the comparison of two such models considering a real circuit, where the influence of a high-voltage spark gap results in a decrease of the maximal current for about 5%. We review in detail the model [1] based on the time dependent method for the electron number density simulation in the air spark gap channel using an anisotropic solution of the kinetic equation [2].
    [Show full text]
  • I-N + Silicon Structures
    University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Electrical & Computer Engineering, Department P. F. (Paul Frazer) Williams Publications of May 1993 Inhibition of surface-related electrical breakdown of long p+-i-n+ silicon structures F. E. Peterkin University of Nebraska - Lincoln P. F. Williams University of Nebraska - Lincoln, [email protected] B. J. Hankla University of Nebraska - Lincoln L. L. Buresh University of Nebraska - Lincoln S. A. Woodward University of Nebraska - Lincoln Follow this and additional works at: https://digitalcommons.unl.edu/elecengwilliams Part of the Electrical and Computer Engineering Commons Peterkin, F. E.; Williams, P. F.; Hankla, B. J.; Buresh, L. L.; and Woodward, S. A., "Inhibition of surface-related electrical breakdown of long p+-i-n+ silicon structures" (1993). P. F. (Paul Frazer) Williams Publications. 6. https://digitalcommons.unl.edu/elecengwilliams/6 This Article is brought to you for free and open access by the Electrical & Computer Engineering, Department of at DigitalCommons@University of Nebraska - Lincoln. It has been accepted for inclusion in P. F. (Paul Frazer) Williams Publications by an authorized administrator of DigitalCommons@University of Nebraska - Lincoln. inhibition of surface-related electricall breakdown of long p+-i-n+ silicon structures F. E. Peterkin, P. F. Williams, B. J. Hankla, L. L. Buresh, and S. A. Woodward Department of Electrical Engineering, University of Nebraska-Lincoln, Lincoln, Nebraska 68.588-05Il (Received 22 January 1992; acceptedfor publication 10 February 1993) Semiconductors such as silicon and GaAs appear attractive for use in high voltage devices becauseof their high bulk dielectric strength. Typically, however, such devicesfail at a voltage well below that expecteddue to a poorly understood,surface-related breakdown process.In this letter we present empirical results which show that such breakdown of long silicon pf-i-n+ devicescan be inhibited by the application of weak visible or near-infrared illumination.
    [Show full text]
  • Basic Electricity
    BASIC ELECTRICITY STUDY COURSE for Home Appliances HOW TO READ: • WIRING DIAGRAM SYMBOLS • TERMINAL CODES • WIRING DIAGRAMS CABINET GROUND BK W STARTER BALLAST S 1 FLUORESCENT LAMP Module 2 LIT 787740 Rev. C For More Appliance Troubleshooting, Repair Help, & DIY Videos Visit ApplianceAssistant.com Note: This Page was not included by Whirlpool Corporation ApplianceAssistant.com is not affiliated Whirlpool Corporation Whirlpool Corporation in no way endorses ApplianceAssistant.com WHIRLPOOL CORPORATION does not assume any responsibility or any liability in connection with the use of this manual. © 1989, 1993, 2000 WHIRLPOOL CORPORATION All rights reserved. No portion of this book may be reproduced in any form without written permission from WHIRLPOOL CORPORATION. ® The trademarks WHIRLPOOL , , , and FSP are registered trademarks of Whirlpool Corporation. INTRODUCTION The material presented in this module is intended to provide you with an understanding of the fundamentals of electricity as applied to major appliances. Major appliances have become more sophisticated, taking them out of the screwdriver and pliers category. Their electrical circuits include several different types of automatic controls, switches, heaters, valves, etc.. Semiconductors, solid-state controls, and other components usually associated with radio and television electronic circuits, are being engineered into automatic washers, dryers, dishwashers, and refrigerators. The appliance technician is emerging into a professional status of his own. He must prepare himself now to be able to perform his duties today as well as to retain his professionalism in the future. No longer is on-the-job training sufficient to prepare technicians for the complicated procedures required for todays sophisticated appliances. This training can best be obtained through organized classroom study and application.
    [Show full text]
  • Two-Electrode Spark Gap Preamble
    Two-Electrode Spark Gap Preamble INTRODUCTION PRINCIPLES OF OPERATION The range of two-electrode spark gaps offered by e2v A simple two-electrode spark gap is shown in Fig. 1. At low technologies comprises hermetically sealed gas-filled switches voltages the gap is an insulator. As the voltage increases, the available with DC breakdown voltages from 400 V to 50 kV. few free electrons (present in the gap as a result of cosmic Two-electrode spark gap applications include voltage surge radiation and other ionising effects) are accelerated to higher protection, lightning protection, single-shot pulse generators, velocities, until they are able to ionise atoms of the gas filling. high energy switches and turbine engine ignition circuits. This leads to an avalanche effect as the additional electrons produce further ionisation and as the current builds up, the PRINCIPAL FEATURES voltage falls (see Fig. 2). There is a range of current over which emission from the cathode takes the form of a glow discharge * No Standby Power Consumption and the voltage is almost constant. * Consistent Breakdown Voltage * High Current Capability GAS FILLING MAIN ELECTRODE GAP 4169B * Fast Switching * Rugged and Reliable over Temperature Range * Lightweight TWO-ELECTRODE SPARK GAP SELECTION When considering the choice of spark gap, the following factors should be taken into account: * Application * Peak Current and Waveform * Coulombs per Shot INSULATOR * Maximum Repetition Rate * Main Gap Voltage Fig. 1. Basic structure of a typical 2-electrode spark gap * Environmental Conditions A further increase in current produces cathode heating by ion The e2v technologies two-electrode spark gap preamble should bombardment, leading to the formation of emission sites and be read in conjunction with the relevant product data sheet to another voltage drop across the gap.
    [Show full text]
  • PS/6772 It Should Be Noted Here That If, for Any Reason, This Feedback
    14 ins-SI/Note MAE/68~5 5.10.1968 K66 KICKLJ PROJECT C. Carter Introduction This note describes the supplies and associated equipment used to power the FK66 Kicker Magnet. A pulse forming network consisting of two low loss 16 coaxial cables in parallel is charged from a H.V. power supply. At the desired maximum voltage the stored energy in the cables is switched into the magnet which is also matched by a triggered spark gap. As the magnet is a balanced four terminal network? both positive and negative supplies are needed, as are the associated pairs of cables and spark gaps. A change—over switch selects the direction of ‘kick'. A choice of 3 bunch or 6 bunch ejection required two pairs of charging cables (termed the ‘short' and 'long' cables), and thus four individual power supplies (Fig. 1). General description 2 The four similar power supplies are all housed in an oil filled tank. The control element in each is a ML8495 tube, which is held normally off by a rectifier A.C. voltage obtained from a power oscillator. A ramp function generator modulates this oscillator to turn the tube on, which charges the cables (Figs. 2 and 3). A voltage divider chain on the output is used for measurement and also as a reference point for comparison with the applied ramp function. PS/6772 It should be noted here that if, for any reason, this feedback 100p is broken9 control of the series tube ML8495 will be lost resulting in full output voltage on the cables.
    [Show full text]
  • Installation Instructions
    50LC Single Package Rooftop Cooling Only with Puronr (R---410A) Refrigerant Sizes: 04, 05, 06 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS SAFETY CONSIDERATIONS.................... 2 All Units................................ 19 Convenience Outlets....................... 20 INSTALLATION............................... 6 HACR.................................. 21 Jobsite Survey................................ 6 Factory--Option Thru--Base Connections...... 21 Step 1 --Plan for Unit Location.................. 6 Units without Thru--Base Connections......... 22 Roof Mount............................... 6 Field Control Wiring....................... 22 Step 2 -- Plan for Sequence of Unit Installation...... 6 Thermostat............................... 22 Curb--Mount Installation..................... 6 Unit without Thru--Base Connection Kit....... 22 Pad--Mount Installation...................... 7 Heat Anticipator Settings................... 23 Frame--Mount Installation.................... 7 Electric Heaters............................ 23 Step 3 --Inspect Unit........................... 7 Single Point Boxes & Supplementary Fuses.... 24 Step 4 -- Provide Unit Support................... 7 Single Point Boxes without Fuses............ 24 Roof Curb Mount.......................... 7 Low--Voltage Control Connections............ 24 Slab Mount (Horizontal Units Only)........... 7 Humidi--MiZerR Control Connections.......... 25 Alternate Unit Support (In Lieu of Curb or Slab Mount).............
    [Show full text]
  • Operator and Place This Installation Manual in an Accessible Place Near the Operator
    Installation & Instruction Manual OOppeerraa--HH OOppeerraa--JJ Note: Read this manual carefully before installing the operator and place this installation manual in an accessible place near the operator. For future reference record: Model # Date Wiring Diagram # Model # Project No. Project Name Door No. # 2 IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH, READ AND FOLLOW ALL INSTRUCTIONS. 1. Never allow children to operate or play with or near door. 2. Check to see that the operator is correct for the type, size of door and frequency of use per the operator specifications. 3. If the door system is near a residential area, or pedestrian traffic is expected near the door system, additional equipment such as electric reversing edges, photocells, or similar devices must be installed as part of the system to prevent entrapment. 4. Reversing devices appropriate to the application must be installed as part of the system. 5. Outdoor or easily accessible controls must be of the security type to prevent unauthorized use of the system. 6. Place controls far enough from the door so that a user cannot touch the door when operating the controls. 7. Controls should be placed so the user has full view of the door when operating. 8. Always keep moving door in sight and away from people or vehicles until it is completely opened or closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 9. If a person is trapped under the door, push the "OPEN" control button. 10. Do not overtighten a clutch to compensate for a damaged door.
    [Show full text]