Electronic regulator Harmonic correction unit Power-Sure 700 & 800 Sag ride-through power Power conditioning products Power-Suppress 100 & 600 conditioner The power to work Basics of power quality The partner you can trust

The PQ PyramidE Utilities struggle to keep up with the unrelenting The key elements of an effective demand for clean power…you can’t rely solely on PQ strategy: them to provide it. The responsibility for PQ rests Interruption solutions Surge protection with the customer—including you. • Reduce problems associated • Eliminates problems associated With Eaton behind you, your company’s operations with outages using UPS, with transients traveling on ac, paralleling switchgear, telephone and communication managers and facility engineers can be assured that generators and/or energy lines their will get the job done, no matter storage devices what level of reliability your company requires. Effective grounding Harmonic mitigation • A well-designed and You wouldn’t use anything other than 100 percent • Many applications require properly installed grounding clean gas in your car, or pure oil in your engine. solutions to reduce harmonic system is required for current and voltage distortion safety and operation of all The same rules apply to your electrical equipment. electrical equipment Without an investment in the quality of power Voltage regulation running this equipment, you can expect downtime • Stabilizes a facility’s voltage and equipment disruption. and eliminates costly problems due to undervoltage and overvoltage events utages Interruptions High Harmonic V istortion Solution Voltage Variations and Sags

Voltage Surges

rounding onding

ow V Solution PQ Pyramid

EATON Power conditioning products 2 A total solution

The right power quality solution rnser ronic is site and industry specific. Power witces itigting rnsorer quality meters are required to help Protectie ctor you capture and analyze your es rnsorer facility’s power disturbances. If you Predictie rounding can’t measure it, you can’t manage it. ignostics nd Prti igting iscrge stes A power quality engineer can help ninterruptie Power companies interpret data and identify Power upp ctor the most cost-effective solutions. orrection With today’s increasingly complex facilities and interconnected Other Harmonic Power networks, the number of problems Solutions istriution that can result from poor power quality are significant. Eaton power Surge enertion system engineers are PQ experts Protection witcger who can help you realize the full benefits of your investment. Isolation Power Transformers uality Armed with this information, eters Sag Voltage you can select the Eaton Correction egulation products that are right for you.

EATON Power conditioning products 3 Solutions to all of your power quality needs

An investment in Eaton power quality (PQ) solutions is one that will pay dividends immediately. It keeps your equipment, and your company, working. That means you avoid costly downtime. We’ll help you protect your investment in an increasingly digital world.

Overview Eaton offers a wide range of power conditioning solutions. These solutions range from small single-phase isolation units to megawatt sag correction units. Eaton has the engineering expertise and products to solve your power quality problem.

Protects equipment from: Ratings • Voltage sags • 500 VA to 50 MVA • Line noise • 50/60 Hz • Voltage transients/surges • Voltage 120 V to 36 kV • Under/overvoltage events • Single-phase and three-phase • Swells • Harmonics

EATON Power conditioning products 4 Power conditioning product selection chart Eaton power conditioning products are designed to protect your critical equipment against common power quality problems. Power Power quality Transient Noise Voltage Voltage sag Harmonic interruption product/protection activity suppression regulation correction protection protection Isolation correction Uninterruptible power supply n n n n n n Power-SureE 700 n n n n n n Power-SureE 800 n n n n n n Power-SuppressE 600 n n n n Power-SuppressE 100 n n n n Surge protective devices n n Sag ride-through devices (SRT2) n n n Harmonic correction units (HCU2) n n

Power conditioning application chart

Power Power quality Single- Three- Test Audio Data interruption Factory Critical product/protection phase phase equipment systems centers protection Isolation automation systems Uninterruptible power supply n n n n n n Power-SureE 700 n n n n n Power-SureE 800 n n n n n Power-SuppressE 600 n n n n n Power-SuppressE 100 n n n n n Surge protective devices n n n n n n n Sag ride-through devices (SRT2) n n n n Harmonic correction units (HCU2) n n n n

EATON Power conditioning products 5 Power conditioning voltage regulators

Power-Sure 700— Power-Sure 800— Sag ride-through three-phase single-phase power conditioner (SRT2) • Ratings from 10 kVA to • Ratings from 500 VA to 25 kVA • Up to 30 seconds of voltage 500 kVA sag ride-through • Voltage range from • Voltage from 208 V to 600 V 120 V to 480 V • 99% efficient (typical) • Seven taps per phase for • Office models • Does not lower fault capacity optimal regulation (with receptacles) • Continuous voltage regulation • Response time of 1/2 cycle • Hardwired models (wall/panel • Voltage harmonic reduction mount and floor mount) • Output correction within • Voltage balance correction 1.5 cycles • Line regulation ±3% V-out for +10% to –20% V-in at • Extensive diagnostics • ±3% voltage output for a 100% load +10% to –23% voltage input • Voltage event log • Load regulation ±3% for • Less than 1% THD • 0–75% load to ±2% for Separate coupling transformer • Unit not affected by load 100% load • Continuous sag correction power factor survives multiple sag events • Immunity to distortion at 40% without recharging • High efficiency of THD V-in, 5% max. THD V-out for extra time savings approximately 97% • Ride-through capability of • Small design and footprint • Frequency range of 57–63 Hz 1 cycle significantly reduces required • Bypass switch (optional on • Voltage recovery of 2 cycles to floor space 45 kVA and smaller units) 95%, 3 cycles to 100% • Battery-free design eliminates • Triple-shielded isolation • K-30 rated K-factor costly maintenance and transformer disposal requirements • Harmonic attenuation of • Overtemperature protection –23 dB for load-reflected • No minimum load improves harmonics operating flexibility for • Optional surge protection unit fluctuating loads or processes • Surge protection of 330 V • Optional metering let-through voltage • Sub-cycle response patented • Front access only for circuit enables extremely fast • Common mode noise 2 ms response (1/8 cycle) Power-Sure 700 50–150 kVA units attenuation of 140 dB • One-year warranty • Transverse mode noise attenuation of 120 dB • Reliability of 200,000 hours (MTBF) • Audible noise of 52–56 dB at 1 meter • Efficiency of 92% at full load • Operating temperature of –20 °C to +40 °C • Two-year warranty

Power-Sure 800

Sag ride-through (SRT2)

EATON Power conditioning products 6 Power conditioning and isolation

Power-Suppress 100— Power-Suppress 600 Harmonic correction unit single-phase isolation transformer • Can be sized to guarantee • Traps unwanted harmonics • Common mode noise specific levels of harmonic attenuation: correction, such as meeting • Sizes from 500 VA to 7.5 kVA IEEET 519 recommended • 126 dB—standard double • from 120 V to 480 V (2) shield levels • Common mode noise • Cannot be overloaded • 146 dB—optional triple attenuation of 140 dB (3) shield • Can be expanded without at 100 kHz affecting performance • Transverse mode noise • Normal mode noise attenuation: • Broad spectrum of cancellation attenuation of 65 dB (2nd to 51st harmonic) at 100 kHz • 3 dB down at 10 kHz, decaying 20 dB per decade • Power factor improvement • Overload capacity of 600% for 1 cycle, 300% for 30 seconds • Decaying 40 dB with • Easier and less expensive “SPD With High installation • Frequency of 60 Hz ±5% Frequency” option • Comprehensive control • Efficiency of 93–97% • Overload capacity up to • Fast action • Adds less than 1% THD 500% for 10 seconds, under linear loading 1000% for 1 cycle • 20 kHz switching carrier frequency, 25 μs full • Temperature rise 115 °C above • K-13 rated response time a 40 °C ambient • Overtemperature protection • UL/CSAT approved • Removes surge voltages and • Clean, noise-free power minimizes reflected THD • 380–480 V ±10%, 600 V and output 690 V with autotransformer • Cleans and conditions the • Fast, easy installation sine wave • 50/60 Hz ±3 Hz frequency • Optional ULT 1449 4th Edition • Eliminates load-generated • Ambient temperature 0 °C and UL 1283 7th Type 2 feedback to +40 °C enclosed surge suppressor • Available in both hardwired or • Seismic Zone 4 • UL and cULT listed Harmonic Correction Unit line cord/receptacle models requirements • NEMA 1, NEMA 2, NEMA 12, • Fast and easy installation IP31, IP54 and chassis-mount • Frequency of 60 Hz ±5% versions available: • Long-life operation • Efficiency: • Wallmount (NEMA 1 • Small footprint • Meets and exceeds U.S. designs) • Two-year warranty Department of Energy • Floor-standing (NEMA 2, (DOE) 2016 high efficiency NEMA 12, IP31 and IP54) standards identified under DOE 10 CFR Part 431 • Output capacity—self-limited to 100% current rated • Meets and exceeds CSA Standard C802.2-12 • Corrective capability— <5% TDD and near unity • Output impedance 2% to displacement power factor A 3.5% typical • Color HMI touchscreen display • Output distortion less than Power-Suppress 100 1.0% THD added under • Efficiency: losses at 480 V linear load <3%; losses at 690 V <5% • The solated neutral establishes • Closed loop control a new neutral to ground bond on the transformer’s output A Requires at least 3% series input line reactor ahead of large nonlinear loads. • Protects loads from voltage and current distortions caused from triplen harmonics (3rd, 9th, 15th, 21st, etc.) • One-year warranty

Power-Suppress 600

EATON Power conditioning products 7 We make what matters work.*

At Eaton, we believe that power is a fundamental part of just about everything people do. Technology, transportation, energy * and infrastructure—these are things the world relies on every day. That’s why Eaton is dedicated to helping our customers find new ways to manage electrical, hydraulic and mechanical power more efficiently, safely and sustainably. To improve people’s lives, the communities where we live and work, and the planet our future generations depend upon. Because that’s what really matters. And we’re here to make sure it works. See more at Eaton.com/whatmatters

For application support, call our engineers at 800-809-2772, option 4, sub-option 2. For details, visit Eaton.com/pc.

Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com

© 2018 Eaton Follow us on social media to get the All Rights Reserved Eaton is a registered trademark. latest product and support information. Printed in USA Publication No. BR158001EN / Z21752 All other trademarks are property November 2018 of their respective owners.