SPD, Power Conditioning, PF and Harmonic Filters

Industrial Surge Protection Products 10.1 Introduction 10 Industrial and Commercial Surge Protection ...... 2 Datacom Protection ...... 2 10 Critical Load Protection...... 2 Telecommunications Protection ...... 3 10 Power Conditioning ...... 3 10 10.2 Surge Protective Devices (SPD) Product Overview ...... 6 10 SPD Series for Integration into Electrical Distribution Equipment ...... 8 10 SPD Series for Mounting External to Electrical Distribution Equipment . . . . . 12 CVL Surge Protective Device ...... 17 10 AEGIS Powerline Filters ...... 19 CVX050/100 ...... 22 10 Datacom ...... 25 10 10.3 Power Conditioning Products 10 Sag Ride Through (SRT) ...... 26 Electronic Regulator (EVR) ...... 32 10 10.4 Correction Capacitors 10 Product Overview ...... 34 UNIPUMP ...... 37 10 UNIPAK ...... 40 AUTOVAR 300 Automatic Power Factor Correction Systems . . . . . 51 10 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems . . . . . 54 10 AUTOVAR Filter—LV Automatic Harmonic Filter ...... 59 Transient-Free Static Switching Power Factor Correction Units ...... 63 10 Active-Harmonic Filter-Harmonic Correction Unit—NEMA 1 Enclosure . . . . . 67 10 10 10 10 10 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 1

10.1 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Introduction

10 Industrial and Commercial Surge Protection Contents Description Page 10 Telecommunications Protection ...... 3 Power Conditioning ...... 3 10 Application Description ...... 4 Facility-Wide Power Protection Solutions ...... 5 10 10 10 10 10 10

10

10 Industrial and Commercial Surge Protection Critical Load Protection Datacom Protection 10 ● SPD Series for Integration SPD Series Sidemount Units ● AEGIS-HW: Series filters Eaton’s line of data and into Electrical Distribution Specification grade surge for up to 20 amperes, communication surge Equipment protective devices for single-phase (protection for suppression products are 10 ● SPD Series for Mounting installation external to PLCs, control equipment) available for nearly any External to Electrical electrical distribution ● AEGIS-VL: Hardwired configuration and offer 10 Distribution Equipment equipment. surge filter that protects complete protection for critical loads up to computers and small to 10 SPD Series Integrated Units 5 amperes large networks, including the following: Specification grade surge ● OEM components: 10 protective devices installed A wide variety of ● Modular protection for within Eaton’s electrical components for domestic/ multi-pair applications assemblies. international applications 10 ● Hardwire connected (including military) (one or two pair protectors) 10 ● Wiring connectors (D89, DB25 and RJ11) 10 ● Coaxial cable protection ● Mounting hardware 10

10 SPD Series Sidemount Unit 10 10

10 Datacom Products

10 AEGIS Products 10 SPD Series Integrated Unit 10 10 10 10

2 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com

SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.1 Introduction

Telecommunications Protection 10 Eaton’s Telecommunication Panelboards with Integrated surge suppression products Surge Protective Devices are designed to safeguard ● Available in standard and 10 against harmful and potentially custom configurations disastrous surges and spikes. ● Ratings: 10 Our data communication and ● 120/240 Vac, single- telecommunication surge phase, three-wire 10 suppression solutions protect your equipment from the ● 208Y/120 Vac, three- damage frequently caused by phase, four-wire 10 lightning strikes, brownouts, ● 480Y/277 Vac, three- electrical load switching, faulty phase, four-wire 10 wiring, downed power lines ● 600Y/347 Vac, three- and more. This unique line phase, four-wire (other Surge Protective Devices can be 10 Integrated within a variety of Eaton was developed to protect voltage configurations Electrical Assemblies against the harmful are available) 10 surges that threaten your telecommunication circuits. ● Copper bus ● 12, 18, 24, 30, 36 and 10 42 circuits ● Bolt-on branch breakers 10 ● A full range of factory installed modifications 10 and accessories ● Fully rated or series rated 10

Power Conditioning 10

Sag Ride Through (SRT) Electronic Voltage 10 The sag ride through (SRT) Regulator (EVR) is a power conditioner that The electronic voltage 10 corrects voltage sags to regulator (EVR) is designed maintain uptime and to meet the needs of 10 productivity. customers who experience voltage regulation problems due to brownout conditions 10 from their electric utilities. 10 10 10 10 Sag Ride Through (SRT) Electronic (EVR) 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 3

10.1 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Introduction

10 Application Description

10 Application Recommendations for Surge Products 10 Application Type Eaton’s Surge Product Features and Competitive Advantages Light Commercial 10 Design build SPD Series integrated units Ideal package for any commercial facility Chain stores SPD Series sidemount units Cost-effective, reliable protection using the SPD Series or CVL units 10 Small facilities CVL units CVX units 10 Large Projects Including: SPD Series integrated units in panelboards, switchboards, Able to meet competitors’ SPD specifications 10 Commercial MCCs, switchgear, busway and automatic transfer switches Increased surge protection performance by using integrated SPD Series units Government SPD Series sidemount units Wall space savings by using integrated SPD Series units 10 Schools CVL units Quick-ship capabilities from Eaton assembly satellites and service centers Institution Datacom surge protectors Power conditioning capability for a wide variety of applications 10 Military AEGIS units for critical load applications Power conditioners (EVR and SRT units) 10 Industrial Including: SPD Series integrated units in panelboards, switchboards, Increased surge protection performance by using integrated SPD Series units 10 Small and large facilities MCCs, switchgear, busway and automatic transfer switches Wall space savings by using integrated SPD Series units 10 WWTP SPD Series sidemount units MCCs with SPD Series units installed protect drives from damage CVL units AEGIS products protect expensive critical loads from harmful damage AEGIS units for critical load applications such as PLCs, EVR units correct voltage regulation problems 10 robotics applications, etc. SRT units correct voltage sag problems Power conditioners (EVR and SRT units) 10 OEM Any OEM customer including: SPD Series integrated units Years of experience in a variety of OEM applications 10 Integrators SPD Series sidemount units Application assistance and recommendations Medical equipment CVL units Small footprint enables integration in a variety of applications 10 Automation and control CVX units Ability to meet customized requirements Datacom surge protectors 10 AEGIS units for critical load applications 10 Telecommunications Including: Panelboards and automatic transfer switches with integrated SPD Series units Ability to meet customized requirements 10 Cellular sites SPD Series sidemount units Application assistance and recommendations Microwave CVL units 10 PCS CVX units Paging systems 10 10 10 10 10 10 10 10 10 10

4 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com

SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.1 Introduction

Facility-Wide Power Protection Solutions 10 A facility-wide protection recommended design 1. Ensure proper 2. Surge protection should approach should be approach for implementing grounding conditions be installed at key employed to address power facility-wide Eaton power exist. All forms of power distribution panels 10 quality issues. This approach protection solutions. protection/conditioning and critical loads. minimizes overall lifecycle rely on good grounding, 10 costs and optimizes facility The most accepted design bonding and earthing uptime. The following is a methodology is based on practices. two concepts: 10 10 Application of Surge Protection, Voltage Regulation and Sag Correction Devices 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 5

10.2 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protective Devices (SPD)

10 SPD Series Sidemount Units Contents Description Page 10 Surge Protective Devices (SPD) SPD Series for Integration into Electrical 10 Distribution Equipment ...... 8 SPD Series for Mounting External to Electrical 10 Distribution Equipment ...... 12 CVL Surge Protective Device ...... 17 10 AEGIS Powerline Filters ...... 19 CVX050/100 ...... 22 10 Datacom ...... 25 Learn 10 Online 10 10

10

10 Product Overview 10 Product Description Features, Benefits and Functions Eaton’s SPD series surge A complete offering of ● Utilizes thermally Safety Features 10 protective devices are the sidemount units designed protected metal oxide ● All units utilize thermally latest and most advanced for mounting external to varistor (MOV) technology protected metal oxide ® 10 UL 1449 3rd Edition certified electrical distribution ● Three feature package varistor technology (MOV) surge protectors. Units are equipment is also available. options as their core surge available integrated within Application of SPD Series 10 ● True protection status suppression component. Eaton electrical assemblies, units throughout a facility indicators report the status Usage of this technology including panelboards, will ensure that equipment of the protection elements, ensures safe operation 10 switchboards, motor is protected with the safest not the status of the when the unit is subjected control centers, switchgear, and most reliable surge applied power to abnormal conditions automatic transfer switches protective devices available. 10 ● such as temporary and bus plugs. SPD Series units are available Available integrated within the following overvoltage or high fault in all common and current conditions. Under 10 configurations and also Eaton electrical assemblies: panelboards, switchboards, such conditions, the in a variety of surge current thermally protected MOVs 10 capacity ratings from 50 motor control centers, switchgear, automatic are removed from the through 400 kA. Three circuit quickly and safely feature package options are transfer switches and 10 bus plugs before a potentially unsafe also available to choose from, condition can occur ensuring the proper unit is ● 10-year warranty 10 ● SPD Series units contain available for a variety of no replaceable parts such 10 SPD Series Integrated Units applications. as surge modules, fuses, or surge counter memory backup batteries. This 10 prevents potential arc flash and shock hazards, as the 10 units require no periodic service or user intervention 10 after installation ● Integrated versions of the 10 unit are factory installed and sidemount versions 10 are factory sealed. These important safety measures further enhance user 10 safety 10 10

6 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com

SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.2 Surge Protective Devices (SPD)

Three Feature Package Standard Feature Package Side-By-Side Comparison of the SPD Series’ Available Options Available The standard feature package Feature Packages 10 The SPD Series provides includes all of the features Standard with users with the option of found in the basic feature Feature Package Comparison Basic Standard Surge Counter 10 package, plus an audible alarm selecting between three ■ ■■ with silence button, EMI/RFI Surge protection using thermally protected feature packages. These MOV technology 10 feature packages are the filtering, and a form ‘C’ relay ■■ ■ basic, standard and standard contact that can be used for Dual-colored protection status indicators for each phase with surge counter. The remote annunciation of the 10 proper feature package SPD’s status. The audible Dual-colored protection status indicators ■■ ■ can be selected based on alarm activates and the form for the N-G protection mode 10 the requirements of the ‘C’ relay contact changes state Audible alarm with silence button ■■ application or specification. when any loss of protection is Form ‘C’ relay contact ■■ 10 A side by side comparison of detected or a fault condition ■■ the individual features found exists with the unit. Should EMI/RFI filtering, providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz 10 in each package is below. such a condition occur, the audible alarm can be silenced Surge counter with reset button ■ Basic Feature Package by pressing the silence button. 10 The basic feature package is The EMI/RFI filter provides up Standards and Certifications Technical Data perfect for applications where to 50 dB of noise attenuation ● Integrated versions of and Specifications 10 basic, cost-effective, safe and over the range of 10 kHz the unit are UL 1449 ● reliable surge protection is through 100 MHz. 20 kA nominal discharge required, but budgets don’t 3rd Edition recognized current (In) rating 10 allow for extra, additional Standard with Surge components for the (maximum rating features. Rather than Counter Feature Package United States and Canada, assigned by UL) 10 sacrifice performance or The standard with surge covered by Underwriters ● 50 through 400 kA surge safety due to cost, SPD counter feature package Laboratories certification current capacity ratings 10 and follow-up service Series units with the basic includes all of the features ● 200 kA short-circuit current feature package provide you found in the standard feature ● Sidemount versions are rating (SCCR) 10 with high-performing surge package plus a six-digit surge UL 1449 3rd Edition listed protection without sacrificing counter with a reset button. devices and are also safety or reliability. The basic The surge counter indicates CSA approved 10 feature package provides the ongoing count of the the same level of surge number of surges the unit has 10 protection and safety been exposed to and stores provided by the standard and them in nonvolatile memory. 10 standard with surge counter Should power to the SPD feature packages minus Series unit be completely some of the features found in interrupted, the surge counter 10 them. The package contains will recall and display the dual-colored protection status surge count prior to the 10 LEDs that report the true interruption when power is status of the protection in restored. Unlike many surge 10 each phase/mode. All four- protectors, the SPD Series’ wire plus ground units also surge counter memory 10 contain an additional set of feature does not require a dual-colored protection status backup battery that would LEDs that report the status require periodic replacement 10 of the protection in the in order to achieve its neutral/ground mode. memory functionality. 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 7 10.2 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protective Devices (SPD)

10 SPD Series Unit Integrated within an Eaton Panelboard Contents Description Page 10 Product Overview ...... 6 SPD Series for Integration into Electrical 10 Distribution Equipment Standards and Certifications ...... 9 10 Catalog Number Selection ...... 9 Technical Data and Specifications ...... 10 10 Dimensions ...... 11 SPD Series for Mounting External to Electrical 10 Distribution Equipment ...... 12 CVL Surge Protective Device ...... 17 10 AEGIS Powerline Filters ...... 19 CVX050/100 ...... 22 10 Datacom ...... 25 10

10

10 SPD Series for Integration into Electrical Distribution Equipment 10 Product Description Application Description Eaton’s SPD Series surge The SPD Series is available as The Integrated SPD 10 protective devices are the an integrated device within Performance Advantage latest and most advanced the following Eaton electrical Installation conductor length 10 UL 1449 3rd Edition certified assemblies: is the single most important surge protectors. SPD Series factor related to an SPD’s ● Panelboards units are available in all performance. Performance 10 common voltages and ● Switchboards decreases as the connected configurations, and also in ● Motor control centers conductor length increases. 10 a variety of surge current ● Switchgear Integrating the SPD within the capacity ratings from ● Automatic transfer electrical assembly provides 50–400 kA. 10 switches the best possible surge protection by keeping ● 10 Bus plugs installation conductor lead Features, Benefits lengths as short as possible. Integrating the SPD within In this installation, the SPD Series and Functions is mounted directly to the panelboard’s 10 an electrical assembly can ● bus bars. This type of installation Uses thermally protected decrease let-through will provide the best possible surge metal oxide varistor (MOV) protection by minimizing the 10 voltages by hundreds of volts, connected lead length. technology providing you with the best 10 ● Three feature package possible surge protection for options sensitive electronic loads. ● 10-year warranty 10 Remote Display Mounting Option Available 10 The SPD Series offers the option of mounting its display 10 remotely from the device. This is useful for applications 10 where OEMs or other integrators would like to embed the unit within a piece 10 of equipment and still be able 10 to view its display.

10 The SPD Series is also available as an integrated unit interfaced via a circuit breaker resident in the electrical 10 assembly. This installation keeps connected lead lengths short while providing a means of disconnecting 10 power to the unit quickly and easily.

8 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.2 Surge Protective Devices (SPD)

Standards and Certifications ● UL 1449 3rd Edition 10 recognized component for the United States 10 and Canada, covered by Underwriters Laboratories 10 certification and follow-up service 10 ● UL 1283 (Type 2 SPDs only) 10 10 10 Catalog Number Selection 10

SPD Series Units Mounted Internal to Electrical Distribution Equipment 10 SPD 250 480D 2 J 10 10 Series Application—Integrated Units SPD = Surge protective device kA Rating A = Panelboards (PRL1a, 2a, 3a, 3E), direct bus mounted 10 050 = 50 kA per phase Voltage Code B = Switchgear (includes remote display) 080 = 80 kA per phase 240S = 120/240 single split-phase C = Panelboards (PRL1a, 2a, 3a, 3E, 4), switchboards, 100 = 100 kA per phase 208Y = 120/208 wye (4W+G) busway 10 120 = 120 kA per phase 220Y = 127/220 wye (4W+G) J = Motor control centers 160 = 160 kA per phase 400Y = 230/400 wye (4W+G) 200 = 200 kA per phase 480Y = 277/480 wye (4W+G) 10 Feature Package 250 = 250 kA per phase 600Y = 347/600 wye (4W+G) 300 = 300 kA per phase 240D = 240 delta (3W+G) 1 = Basic 10 400 = 400 kA per phase 480D = 480 delta (3W+G) 2 = Standard 600D = 600 delta (4W+G) 3 = Standard + surge counter 240H = 240 high-leg delta (4W+G) on ‘B’ phase 10 Notes 10 Please consult the factory for 240 high-leg Delta (4W+G) applications with high leg on ‘C’ phase. Units used in PRL1a, 2a, 3a and 3E panelboard applications are available in 50–200 kA ratings only. Use the ‘C’ option for PRL1a, 2a, 3a and 3E panelboard applications when unit is connected through a circuit breaker. 10 Example: SPD250480D2J = SPD Series, 250 kA per phase, 480D voltage, standard feature package, motor control center application. 10 10 10 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 9 10.2 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protective Devices (SPD)

10 Technical Data and Specifications

10 SPD Series Specifications 10 Description Specification Surge capacity ratings available 50, 80, 100, 120, 160, 200, 250, 300, 400 kA per phase

10 Nominal discharge current (In) 20 kA (maximum rating assigned by UL) Short-circuit current rating (SCCR) 200 kA 10 SPD type Basic feature package = Type 1 (can also be used in Type 2 applications) Standard and standard with surge counter feature packages = Type 2 10 Single split-phase voltages available 120/240 Three-phase wye system voltages available 120/208, 127/220, 230/400, 277/480, 347/600 10 Three-phase delta system voltages available 240, 480, 600 10 Input power frequency 50/60 Hz Power consumption (basic units): 10 208Y, 220Y, 240S, 240D and 240H voltage codes 0.5W 400Y, 480Y and 480D voltage codes 1.1W 10 600Y and 600D voltage codes 1.3W 10 Power consumption (standard and standard with surge counter units): 208Y, 220Y, 240S, 240D and 240H voltage codes 0.6W 10 400Y, 480Y and 480D basic voltage codes 1.7W 600Y and 600D voltage codes 2.1W 10 Protection modes Single split-phase L-N, L-G, N-G, L-L Three-phase wye L-N, L-G, N-G, L-L 10 Three-phase delta L-G, L-L 10 Three-phase high-leg delta L-N, L-G, N-G, L-L Maximum continuous operating voltage (MCOV): 10 240S, 208Y, 220Y and 240H MCOV 150 L-N, 150 L-G, 150 N-G, 300 L-L 400Y and 480Y MCOV 320 L-N, 320 L-G, 320 N-G, 640 L-L 10 600Y MCOV 420 L-N, 420 L-G, 420 N-G, 840 L-L 240D MCOV 320 L-G, 320 L-L 10 480D MCOV 640 L-G, 640 L-L 10 600D MCOV 840 L-G, 840 L-L Ports 1 10 Operating temperature –40°F through 122°F (–40°C through 50°C) Operating humidity 5% through 95%, noncondensing 10 Operating altitude Up to 16,000 ft (5000m) 10 Seismic withstand capability Meets or exceeds the requirements specified in IBC 2006, CBC 2007 and UBC Zone 4 Form C relay contact ratings 150 Vdc or 125 Vac, 1A maximum Form C relay contact logic Power ON, normal state—NO contact = open, NC contact = closed 10 Power OFF or fault state—NO contact = closed, NC contact = open 10 EMI/RFI filtering attenuation Up to 50 dB from 10 kHz to 100 MHz 10 10 10 10 10 10

10 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.2 Surge Protective Devices (SPD)

Dimensions Approximate Dimensions in Inches (mm) 10 10 50—200 kA Integrated Units

Mounting 10 0.22 3x Bus Mounting 8.80 (5.6) (223.5) 4.40 10 0.19 (111.8) 4x Mounting 0.04 2.02 2.02 0.34 (4.8) 10 Bus (1.0) (51.2) (51.2) (8.6)

0.95 NEUTRAL 10 NEUTRAL NEUTRAL (24.1) NEUTRAL

5.40 10

Mounting CAUTION  SPD Series (137.2) 3.42 Surge Protective Device 10 (86.9) 4.66 3.42 (118.4)

(86.9) FORM “C” CONTACTS

TORQUE

GROUND 10 NEU/GND

36 IN. LBS. SURGE SURGE GROUND SURGE

SURGE SURGE GROUND GROUND 10

2.52 3.42 0.22 0.26 4x Mounting (64.0) (86.9) (5.6) 10 (6.6) 3.45 Terminals 4x #10–32 x 0.38 DP (87.6) 8.74 Brass Terminals 10 (222.0) 9.50 (241.3) 10 10 250—400 kA Integrated Units

Mounting 10 8.80 4x Mounting (223.5) 10 2.52 3.42

(64.0) (86.9) 10 GROUND GROUND

SURGE SURGE

SURGE GROUND SPD Series SURGE

36 IN. LBS. IN. 36 Surge Protective Device 10 NEU/GND GROUND

3.42 Mounting TORQUE FORM “C” CONTACTS (86.9) 3.42 CAUTION  5.40 10 (86.9) (137.2) 4.66 10 (118.4)

TORQUE NEU/GND 1.71 36 IN. LBS. 10

NEUTRAL NEUTRAL

NEUTRAL (43.4) NEUTRAL 10 Terminals 0.22 4.85 4x Mounting (123.2) 8.74 (5.6) (222.0) 10 5.78 9.50 4x #10–32 x 0.38 DP (146.8) (241.3) Brass Terminals 10 Weights 10 ● 50–200 kA units approximately 3.5 lbs (1.6 kg) 10 ● 250–400 kA units approximately 7.0 lbs 10 (3.2 kg) 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 11 10.2 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protective Devices (SPD)

10 Eaton SPD Series Sidemount Unit Mounted Externally to an Eaton Panelboard Contents Description Page 10 Product Overview ...... 6 SPD Series for Integration into Electrical 10 Distribution Equipment ...... 8 SPD Series for Mounting External to Electrical 10 Distribution Equipment Catalog Number Selection ...... 13 10 Technical Data and Specifications ...... 14 Dimensions ...... 15 10 CVL Surge Protective Device ...... 17 AEGIS Powerline Filters ...... 19 10 CVX050/100 ...... 22 10 Datacom ...... 25 10

10

10 SPD Series for Mounting External to Electrical Distribution Equipment 10 Product Description Features, Benefits Standards and Certifications Eaton’s sidemount versions and Functions ● UL 1449 3rd Edition 10 of the SPD Series surge ● Uses thermally protected listed device protective devices are the metal oxide varistor (MOV) ● Canadian Standards 10 latest and most advanced technology Association (CSA) UL 1449 3rd Edition listed ● Three feature package ● UL 1283 (Type 2 surge protectors. Application options SPDs only) 10 of SPD Series units ● 10-year warranty throughout a facility will 10 ensure that equipment is protected with the safest and 10 most reliable surge protective devices available. Units are All SPD Series sidemount units come available in all common prewired and include a factory- 10 voltages and configurations, installed conduit interface, and also in a variety of surge making installation very easy. 10 current capacity ratings from 50 through 400 kA. Three 10 feature package options are also available to choose from. 10 10

All SPD Series units are factory sealed, 10 ensuring that the user/installer has no potential of coming into contact with harmful voltages present 10 inside the unit. 10 10 10 10 10 10

12 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.2 Surge Protective Devices (SPD)

Catalog Number Selection 10 SPD Series Units for Mounting External to Electrical Distribution Equipment 10 SPD 250 480D 2 K 10

Series Application—Sidemount Units 10 SPD = Surge protective device kA Rating K = NEMA 1 enclosure 050 = 50 kA per phase Voltage Code L = NEMA 1 flushmount enclosure 10 080 = 80 kA per phase 240S = 120/240 single split-phase M = NEMA 1 enclosure with internal disconnect 100 = 100 kA per phase 208Y = 120/208 wye (4W+G) N = NEMA 4 enclosure 10 120 = 120 kA per phase 220Y = 127/220 wye (4W+G) O = NEMA 4 enclosure with internal disconnect 160 = 160 kA per phase 400Y = 230/400 wye (4W+G) P = NEMA 4X enclosure (stainless steel) 200 = 200 kA per phase 480Y = 277/480 wye (4W+G) Q = NEMA 4X enclosure with internal disconnect 10 250 = 250 kA per phase 600Y = 347/600 wye (4W+G) (stainless steel) 300 = 300 kA per phase 240D = 240 delta (3W+G) 400 = 400 kA per phase 480D = 480 delta (3W+G) 10 600D = 600 delta (4W+G) Feature Package 240H = 240 high-leg delta (4W+G) on ‘B’ phase 1 = Basic 10 2 = Standard 3 = Standard + surge counter 10 Notes Please consult the factory for 240 high-leg delta (4W+G) applications with high leg on ‘C’ phase. 10 NEMA 1 flushmount units are available in 50–200 kA ratings only. Example: SPD250480D2K = SPD Series, 250 kA per phase, 480D voltage, standard feature package, housed in NEMA 1 enclosure. 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 13 10.2 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protective Devices (SPD)

10 Technical Data and Specifications 10 SPD Series Specifications Description Specification 10 Surge capacity ratings available 50, 80, 100, 120, 160, 200, 250, 300, 400 kA per phase Nominal discharge current (In) 20 kA (maximum rating assigned by UL) 10 Short-circuit current rating (SCCR) 200 kA SPD type Basic feature package = Type 1 (can also be used in Type 2 applications) 10 Standard and standard with surge counter feature packages = Type 2 Single split-phase voltages available 120/240 10 Three-phase wye system voltages available 120/208, 127/220, 230/400, 277/480, 347/600 10 Three-phase delta system voltages available 240, 480, 600 Input power frequency 50/60 Hz 10 Power consumption (basic units): 208Y, 220Y, 240S, 240D and 240H voltage codes 0.5W 10 400Y, 480Y and 480D voltage codes 1.1W 600Y and 600D voltage codes 1.3W 10 Power consumption (standard and standard with surge counter units): 10 208Y, 220Y, 240S, 240D and 240H voltage codes 0.6W 400Y, 480Y and 480D basic voltage codes 1.7W 10 600Y and 600D voltage codes 2.1W Protection modes Single split-phase L-N, L-G, N-G, L-L 10 Three-phase wye L-N, L-G, N-G, L-L 10 Three-phase delta L-G, L-L Three-phase high-leg delta L-N, L-G, N-G, L-L 10 Maximum continuous operating voltage (MCOV): 240S, 208Y, 220Y and 240H MCOV 150 L-N, 150 L-G, 150 N-G, 300 L-L 10 400Y and 480Y MCOV 320 L-N, 320 L-G, 320 N-G, 640 L-L 600Y MCOV 420 L-N, 420 L-G, 420 N-G, 840 L-L 10 240D MCOV 320 L-G, 320 L-L 10 480D MCOV 640 L-G, 640 L-L 600D MCOV 840 L-G, 840 L-L 10 Ports 1 Operating temperature –40°F to 122°F (–40°C to 50°C) 10 Operating humidity 5% through 95%, noncondensing Operating altitude Up to 16,000 ft (5000m) 10 Seismic withstand capability Meets or exceeds the requirements specified in IBC 2006, CBC 2007 and UBC Zone 4 10 Enclosure dimensions and weights Refer to figures on pages 15–16 for enclosure dimensions and weights Form C relay contact ratings 150 Vdc or 125 Vac, 1A maximum 10 Form C relay contact logic Power ON, normal state—NO contact = open, NC contact = closed Power OFF or fault state—NO contact = closed, NC contact = open 10 EMI/RFI filtering attenuation Up to 50 dB from 10 kHz to 100 MHz 10 10 10 10 10 10

14 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.2 Surge Protective Devices (SPD)

Dimensions Approximate Dimensions in Inches (mm) 10 50–200 kA Units in a NEMA 1 Rated Enclosure, 50–200 kA Units in a NEMA 1 Rated Flushmount Enclosure, 10 Weight = 6.8 lbs Weight = 6.8 lbs

7.28 7.28 10 (184.9) 1.00 Flushmount Panel (184.9) 1.00 5.27 (25.4) (4) #8–32 Flat Hd Screws 5.27 (25.4) (133.9) (133.9) 10 10

10.48 12.05 (306.1) (266.2) 8.00 10 (203.2) 12.05 10.48 11.25 11.25 10 (306.1) (266.2) (285.8) 0.68 (285.8) 0.68 5.24 (17.3) 14.00 5.24 (17.3) (133.1) (355.6) 10 (133.1) Ø0.20 (Ø5.1) Ø0.20 10 (Ø5.1) 0.78 5.00 2.00 (19.8) 0.11 0.40 3.48 (127.0) 10 (50.8) 7.47 0.40 2.00 (88.4) (2.8) (10.2) 7.47 0.78 (189.7) (10.2) (50.8) 4.41 3.48 1.76 (189.7) 0.98 (19.8) (88.4) (112.0) (44.7) 11.00 (24.9) 10 4.41 (279.4) (112.0) 10 250–400 kA Units in a NEMA 1 Rated Enclosure, 50–400 kA Units in a NEMA 1 Rated Enclosure with Internal 10 Weight = 13.5 lbs Disconnect, Weight = 14.7 lbs

1.00 6.69 9.14 10 5.47 (25.4) (169.9) (232.2) (138.9) 10

12.30 0.66 10 12.05 (312.4) (16.8) 10.48 11.50 (306.1) 11.25 10 (266.2) 2.61 10.73 (292.1) (285.8) (66.3) (272.5) 0.67 5.24 (17.0) 10 (133.1) 10 Ø0.20 Ø0.20 2.75 2.00 0.78 (69.9) (Ø5.1) 11.14 (Ø5.1) 7.47 0.78 (50.8) 0.40 (19.8) 5.76 (283.0) 10 5.76 (189.7) (19.8) (10.2) (146.3) (146.3) 6.69 6.55 (169.9) (166.4) 10 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 15 10.2 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protective Devices (SPD)

10 Approximate Dimensions in Inches (mm) 50–200 kA Units in a NEMA 4 or 4X Rated Enclosure, 50–400 kA Units in a NEMA 4 or 4X Rated Enclosure with 10 Weight = 14.6 lbs Internal Disconnect, Weight = 27.5 lbs

10 13.50 SPD Series SPD Series (342.9) Surge Protective Device 12.50 Surge Protective Device 12.75 (317.5) 11.75 11.98 (323.9) 10 (304.3) (298.5) 12.28 10.98 3.12 (311.9) 10 (278.9) 11.28 (79.2)

(286.5)

0.65 Device Protective Surge

5.49 Series SPD

0.65 Device Protective Surge (16.5) (139.4) Series SPD 10 (16.5)

0.76 3.36 10.18 Ø0.33 10 2.60 (19.3) (85.3) (258.6) (Ø8.4) 0.76 6.00 12.47 (66.0) 7.68 (19.3) (152.4) Ø0.33 (195.1) (316.7) 10 5.39 8.65 (Ø8.4) (136.9) (219.7) 10 250–400 kA Units in a NEMA 4 or 4X Rated Enclosure, 10 Weight = 14.6 lbs 10 SPD Series Surge Protective Device 10.98 11.28 10 (278.9) (286.5) 11.75 12.50 (298.5) 10 (317.5)

5.49 0.65 Device Protective Surge

10 (139.4) (16.5) Series SPD

10 4.10 6.00 0.76 (104.1) (152.4) Ø0.33 (19.3) 7.68 8.65 (8.4) 10 (195.1) (219.7) 10 10 10 10 10 10 10 10 10 10 10 10 10 10

16 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.2 Surge Protective Devices (SPD)

CVL Contents 10 Description Page Product Overview...... 6 10 SPD Series for Integration into Electrical Distribution Equipment ...... 8 10 SPD Series for Mounting External to Electrical Distribution Equipment ...... 12 10 CVL Surge Protective Device Catalog Number Selection ...... 18 10 AEGIS Powerline Filters ...... 19 CVX050/100 ...... 22 10 Datacom ...... 25 10 10 10

10

CVL Surge Protective Device 10 Product Description Features, Benefits Standards and Certifications 10 This surge protection device and Functions ● UL 1449 listed, UL 1283 is used to prevent downtime ● SurgePlane™ technology listed, CSA approved 10 and equipment damage. to ensure reliability and ● The UL 1283 listed filter performance by using a Eaton’s CVL is a commercial protects against ringing 10 low impedance copper grade and light industrial transients and EMI/RFI platform surge protective device noise disturbances. The 10 (SPD) that combines surge ● Compact design to tuned suppression filter suppression components and enable close mounting achieves 40 dB attenuation 10 EMI/RFI filtering to provide to electrical distribution at 100 kHz effective protection for equipment sensitive electronic loads. ● Parallel hybrid filter 10 technology ● Individually fused surge 10 suppression components ● Status indicator lights to 10 monitor supply power, surge suppression 10 component status and fusing 10 ● Can be remotely monitored using Form C contacts 10 ● Audible alarm 10 ● Ideal for OEM panel applications 10 ● Proven track record in international applications 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 17 10.2 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protective Devices (SPD)

10 Catalog Number Selection 10 CVL 10 CVL CH BD

10 kA Rating Voltage Code Enclosure 050 = 50 kA/phase 240S = 120/240 Single split-phase RSX = NEMA 1 10 080 = 80 kA/phase 208Y = 120/208 Wye (4W+G) R3R = NEMA 3R 100 = 100 kA/phase 400Y = 230/400 Wye (4W+G) 120 = 120 kA/phase 480Y = 277/480 Wye (4W+G) 10 160 = 160 kA/phase 240D = 240 Delta (3W+G) 200 = 200 kA/phase 480D = 480 Delta (3W+G) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

18 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.2 Surge Protective Devices (SPD)

AEGIS Solutions Contents 10 Description Page Product Overview...... 6 10 SPD Series for Integration into Electrical Distribution Equipment ...... 8 10 SPD Series for Mounting External to Electrical Distribution Equipment ...... 12 10 CVL Surge Protective Device ...... 17 AEGIS Powerline Filters 10 Standards and Certifications ...... 20 Catalog Number Selection ...... 21 10 Technical Data and Specifications ...... 21 CVX050/100 ...... 22 10 Datacom ...... 25 10 10

10

AEGIS Powerline Filters 10 Product Description Application Description Features, Benefits and Functions 10 Eaton’s AEGIS solutions are The AEGIS is the ideal AEGIS powerline filters specifically designed to protection solution for your protect against the full 10 protect expensive electronics critical loads and facilities. spectrum of transient from the hazards that exist disturbances. within a facility. This critical Loads 10 AEGIS filters the entire sine load protection is effective ● Programmable wave and is effective against at reducing harmful surges controllers (PLCs) 10 both frequently occurring low and noise. Applying this ● Scanning devices high performance series energy and occasional high 10 ● powerline filter at your ATMs (Automatic Teller energy transients. High critical loads results in Machines) energy transients can create 10 “clean” power entering the ● Cash registers immediate damage, while electronics and reduction of ● Alarm systems low energy transients cause microprocessor failure 10 “soft” errors, operational ● Microprocessor-controlled over time. malfunction and damage OEM products AEGIS VL Hardwired Critical Load Filter to components. 1, 3 and 5 Ampere Modules Only 10 ● Robotics ● CAD/CAM systems 10 ● Control equipment ● Medical electronics and 10 devices

Why Should Sensitive Electronic 10 Loads be Protected? PLC manufacturers 10 and service technicians recommend the use of 10 surge suppressors and filters Hardwired Surge Filter that Protects Critical Loads (3, 5, 10, to prevent downtime and 15 or 20 Ampere Models) 10 equipment damage due to surges and electrical line noise. One study shows 10 failure to protect sensitive electronic loads costs 10 American manufacturing, commercial and service 10 industries over $39 billion per year in lost time and revenue. Preventing these losses is a 10 major cost-saving opportunity. 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 19 10.2 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protective Devices (SPD)

AEGIS Powerline Filters 10 Features Benefits Unique series hybrid design Protection against high and low energy transients and noise. 10 (AEGIS-HW) The tracking filter reacts instantly to changes in frequency and voltage, regardless of phase angle, magnitude or polarity. Active at all times, providing more protection than a conventional surge suppressor. 10 Extends the life of your microprocessors by eliminating degrading power disturbances. High performance suppression capabilities AEGIS-HW and AEGIS-PR have up to 45,500 amperes of surge current suppression and 75 dB of noise attenuation at 100 kHz. 10 (AEGIS-HW) This guarantees a superior level of protection and reliability. Status monitoring lights No more testing or guessing whether your unit is working properly. Filter indicator lights expedite your troubleshooting efforts during 10 (AEGIS-HW) downtime situations. 5-year downstream equipment warranty Eaton provides a 5-year extended warranty on the microprocessor protected by AEGIS. No other manufacturer offers this level 10 (AEGIS-HW only) of assurance in backing up its claim of product performance, quality and reliability. Value (AEGIS-HW) AEGIS provides superior value when considering the level of performance and benefits offered. It truly delivers the best “bang” for your dollar. 10 Optional remote monitoring capabilities Observe all your operations on a remote basis, including the power protection devices used to safeguard your critical and sensitive (AEGIS-HW, AEGIS VL only) electronic loads. 10 DIN rail, J-rail or flange mounting connections The DIN rail mountable enclosures greatly reduce installation time, effort and cost. This unique container is the preferred choice among OEMs (AEGIS-HW only) and contractors. 10 Thermal cut-off protection (TCO) Thermal fuse improves indication, monitor and control during fault conditions. (AEGIS-HW only) 10 AEGIS Hybrid Series Powerline Filters 10 Three-Wire Design has Normal and Common Mode Protection (L-N, L-G, N-G) 10 Primary Transient High Series High Status Optional Voltage Surge Frequency Blocking Performance Secondary Indicator Form C 10 Suppression (TVSS) Capacitor Track ing Filter TVSS Lights Contacts Power Input Power 10 Output L Normal Normal LED Form C L 10 Mode Mode

10 N N 10 Common Common G G 10 Mode Mode 10 Standards and Certifications 10 ● UL 1283 ● CSA 10 10 Note 10 Option for AEGIS. 10 10 10 10 10 10 10

20 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.2 Surge Protective Devices (SPD)

Catalog Number Selection 10 AEGIS-HW AEGIS-VL 10 AGSHW CH X AGSVL 10

Voltage Code Current Capacity Options Voltage Code Current Capacity 10 120N 03 = 3A S = Standard 120N 1 = 1A 230L 05 = 5A C = Form C contact for 230L 3 = 3A 10 10 = 10A remote monitor 5 = 5A 15 = 15A 20 = 20A 10 10 Technical Data and Specifications

Specifications 10 AEGIS-HW AEGIS-VL Application 2 W&G Grounded Systems 2 W&G Grounded Systems 10 Input voltage single-phase 120, 220, 240 Vac, single-phase 120, 220, 240 Vac, single-phase 10 Amperage 3, 5, 10, 15, 20 amperes 1, 3, 5 amperes Frequency 50/60 Hz 50/60 Hz 10 Protection modes L-N, L-G, N-G L-N, L-G, N-G MCOV 150, 320 volts 150, 320 volts 10 Noise attenuation 10 Normal mode: 75 dB at 100 kHz 75 dB at 100 kHz Common mode: 50 dB at 5 MHz 50 dB at 5 MHz 10 Filter bandwidth 10 kHz to 100 MHz 10 kHz to 100 MHz Total peak surge current 45.5 kA per phase 39 kA per phase 10 Operating temperature –40ºF to +122°F (–40ºC to +50°C) –40ºF to +122°F (–40ºC to +50°C) Response time Less than 1 nanosecond Less than 1 nanosecond 10 Options Form C relay contacts N/A 10 IEEE C62.41 (2002) Test Waveforms for AEGIS-HW and VL Versions 10 Category A Ringwave (Line-to-Neutral) (6000V, 200A) Category B Combination (Impulse) Wave (6000V, 3000A) 10 8000 7000 700 6000 600 6000 5000 500 400 4000 400 10 4000 300 3000 300 ts 2000 ts

l 200 2000 200 l 100 1000 100 Vo Vo 10

Volts 0 0 0 0

Volts -1000 -2000 -100 -100 -2000 -200 -200 -4000 -3000 -300 10 -300 -4000 -400 -6000 -400 20 Microseconds/ 20 Microseconds/ 2 Microseconds/Division 2 Microseconds/Division Division Division 10 Before After Before After 10 Let-Through Voltages (L-N) Description AEGIS-HW (L-N Mode) 10 Category A ringwave (600V, 200A) 6V 10 Category B ringwave (600V, 500A) 9.6V Category B combination (impulse) wave (6000V, 300A) 70V 10 (206V, dynamic at 90°) Notes 10 230V applies to 220 and 240 volt applications. Model rated at 15 amperes UL/CSA = 16 amperes CE. 10 Based on ANSI/IEEE C62.41, 1991 and C62.45, 1992. Static testing. 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 21 10.2 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protective Devices (SPD)

10 CVX050/100A Contents Description Page 10 Product Overview ...... 6 SPD Series for Integration into Electrical 10 Distribution Equipment ...... 8 SPD Series for Mounting External to Electrical 10 Distribution Equipment ...... 12 CVL Surge Protective Device ...... 17 10 AEGIS Powerline Filters ...... 19 CVX050/100 10 Catalog Number Selection ...... 23 Technical Data and Specifications ...... 23 10 Dimensions ...... 24 10 Datacom ...... 25 10

10

10 CVX050/100 10 Product Description Application Description Features, Benefits Standards and Certifications With over two decades of Eaton’s CVX050 and CVX100 and Functions ● UL 1449 3rd Edition for 10 experience in the surge SPDs protect electronic ● Advanced surge path surge protective devices suppression industry and equipment from damaging technology for high fault ● CE marked extensive R&D initiatives, transients. These units are 10 current capacity, low ● Vibration tested IEC Eaton is considered a world suitable for medium and low impedance, high frequency 60255-21-1 and -2 10 leader in surge protective exposure level applications design device (SPD) manufacturing. that require cost-effective, ● Rugged NEMA 4X (IP65) All of Eaton’s products are high quality system enclosure 10 manufactured in an ISO protection including: ● Large diameter, thermally 9001:2000 and ISO 14001 ● protected metal oxide 10 certified facility. Residential/small business ● Light industrial varistors provide long life Eaton’s CVX050/100 models and fail-safe operation ● Light commercial 10 are rugged, cost-effective, ● LED monitoring of each ● Branch panel protection high-quality SPDs that feature phase 10 thermally protected MOVs ● Wide range of voltage that eliminate the failure applications from characteristics of standard 100 to 480 Vac 10 Metal-Oxide-Varistors. The ● 10-year free replacement TPMOV is a fail-safe device warranty 10 that monitors the status of the metal-oxide disk and Optional Features 10 connects itself from the power system when the disk ● Available flushmount for 10 is approaching breakdown. recessed installations The CVX050/100 is easy 10 to install adjacent or even internal to electrical 10 equipment. When installing an SPD in a retrofit environment, it is important to mount the 10 device as close to the electrical equipment as 10 possible. Keep the wiring (lead length) between the electrical 10 equipment and SPD as short as possible, and twist or wire 10 tie the conductors together to reduce the wire’s 10 impedance factor.

22 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.2 Surge Protective Devices (SPD)

Catalog Number Selection 10 CVX050/100 10 CVX - 10

Per Phase Peak Configuration and Voltage Ranges (Vac) 10 Surge Current 230L = Single-phase–200, 208, 220, 230, 240, 277 050 = 50 kA 240S = Split-phase–100/200, 110/220, 120/240 10 100 = 100 kA 208Y = Three-phase wye (star)–100/175, 110/190, 120/208, 127/220 480Y = Three-phase wye (star)–220/380, 230/400, 240/415, 277/480 240D = Three-phase delta–200, 208, 220, 230, 240 10 480D = Three-phase delta–380, 400, 415, 440, 480 10 Technical Data and Specifications 10 CVX050/100 Model Specifications 10 Description Specification kA per phase 50, 100 10 kA per mode 50 Protection modes Wye system: L-L, L-N, L-G and N-G/delta system: L-L, L-G split 10 Wye system voltages 100/175, 110/190, 120/208, 127/220, 220/380, 230/400, 240/415, 277/480 10 Delta system voltages 200, 208, 220, 230, 240, 380, 400, 415, 440, 480 Split-phase voltages 100/200, 110/220, 120/240 10 Single-phase voltages 200, 208, 220, 230, 240, 277 Weight 2.0 lbs (1.0 kg) 10 Operating temperature –13ºF (–25ºC) to + 140ºF (+60ºC) 10

CVX050/100 Let-Through Voltage Ratings 10 Voltage Protection Ratings 10 Model System Nominal System MCOV UL VPR , UL 1449-3 Type Configuration Voltage L-N L-G N-G L-L L-N L-G N-G L-L 10 CVX050 230L Single-phase, two-wire + ground 200, 208, 220, 230, 240, 277 320 640 320 — 1200 2000 1200 — 10 240S Split-phase, three-wire + ground 100/200, 110/220, 120/240 150 300 150 300 700 1200 800 1200 208Y Three-phase wye/star, four-wire + ground 100/175, 110/190, 120/208, 127/220 150 300 150 300 700 1200 800 1200 10 480Y Three-phase wye/star, four-wire + ground 220/380, 230/400, 240/415, 277/480 320 640 320 640 1200 2000 1200 2500 240D Three-phase delta, three-wire + ground 200, 208, 220, 230, 240 — 320 — 320 — 1200 — 2000 10 480D Three-phase delta, three-wire + ground 380, 400, 415, 440, 480 — 550 — 1100 — 1800 — 3000 10 CVX100 230L Single-phase, two-wire + ground 200, 208, 220, 230, 240, 277 320 320 320 — 1200 1200 1200 — 10 240S Split-phase, three-wire + ground 100/200, 110/220, 120/240 150 150 150 300 700 800 700 1200 208Y Three-phase wye/star, four-wire + ground 100/175, 110/190, 120/208, 127/220 150 150 150 300 600 700 700 1000 10 480Y Split-phase, three-wire + ground 100/200, 110/220, 120/240 320 320 320 640 1200 1200 1200 1800 10 240D Three-phase delta, three-wire + ground 200, 208, 220, 230, 240 — 320 — 320 1200 — — 1800 480D Three-phase delta, three-wire + ground 380, 400, 415, 440, 480 — 550 — 1100 1800 — — 3000 10 Notes U.S. voltages in bold. 10 CVX100 model only. Test environment: All tests performed with 6-inch lead length, positive polarity. Voltages are peak ±10%. 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 23 10.2 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protective Devices (SPD)

Dimensions 10 Approximate Dimensions in Inches (mm) 10 CVX050/100 Standard Dimensions

10 5.60 (142.2) 10 4.72 (119.9) 0.75 Internally Threaded 10 4.17 (19.1) Conduit Fitting (105.9) 10 10 3.39 (86.1) 10 4.17 (105.9) 2.36 10 (59.9) 10 A A Mounting 1.12 Holes (28.4) 10 Under 3.53 Lid (4) (89.7) 10 10 10 Mounting Hole Ø 0.17 Shafts 10 (4.3) 10 SECTION A-A 10 10 10 10 10 10 10 10 10 10 10 10 10 10

24 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.2 Surge Protective Devices (SPD)

Datacom Products Contents 10 Description Page Product Overview...... 6 10 SPD Series for Integration into Electrical Distribution Equipment ...... 8 10 SPD Series for Mounting External to Electrical Distribution Equipment ...... 12 10 CVL Surge Protective Device ...... 17 AEGIS Powerline Filters ...... 19 10 CVX050/100 ...... 22 10 10 10 10

10

Datacom 10 Product Description Features and Benefits 10 Eaton’s Datacom surge Exceptional performance is protection products are achieved using three-stage 10 designed for all industries hybrid technology: and applications. The wide ● range of products offers Gas tubes for shunting 10 rugged surge protection in high energy convenient, easy-to-install ● Silicon avalanche 10 configurations. components for responsive, low 10 let-through voltages ● PTC resettable fuses for 10 mitigating fault current ● Our modular design 10 enables customers to protect complete facilities or individual loads. 10 Customers also save significant time and money 10 due to our unique plug-in components and 10 protection modules 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 25 10.3 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Conditioning Products

10 Sag Ride Through (SRT) Contents Description Page 10 Sag Ride Through (SRT) Application Description ...... 27 10 Features, Benefits and Functions ...... 27 Catalog Number Selection ...... 28 10 Technical Data and Specifications ...... 29 Dimensions ...... 31 10 Electronic Voltage Regulator (EVR) ...... 32 10 10 10 10

10

10 Sag Ride Through (SRT) 10 Product Description Eaton’s sag ride through is Today’s industrial and large Depending on the proximity Regularity of Voltage Sags 10 the first of its kind. commercial to the fault, which can be EPRI conducted a two-year customers are becoming hundreds of miles away, study of power quality levels The SRT power conditioner more sensitive to power the voltage during the sag 10 prevents expensive on distribution systems in the disturbances and are is typically 40%–90% of United States. A variation electrical downtime. The demanding better electric nominal utility voltage. The SRT represents Eaton’s event was recorded every 10 quality. However, the quality operation of circuit breakers, time the voltage dropped state-of-the-art solution to of power grids is not fuses and reclosers limits today’s power conditioning below 90% of the nominal. 10 significantly improving. most sags to less than The results are shown below. challenges. Customers still experience 15 cycles. 10 power quality problems A typical distribution system The Problem—Voltage Sags that affect plant operations Voltage sags are experienced customer experiences about and Brownouts and profitability. 10 to 20 times more 50 events per year when the 10 The ability of a plant to frequently than complete voltage drops below 90%, ride through voltage sags Deep, Single-Phase Sag outages. However, voltage and only about two events 10 can have a significant sags are equally disruptive per year when the voltage Input A Input A Input A impact on operations and to sensitive equipment. drops below 30% of nominal. competitiveness. In the 600 10 400 Voltage Sags The utility study concluded United States, voltage sags 200 that sags represented almost 0 cost billions of dollars in 1. Fault occurs on all of the events experienced -200 10 lost production, interruption, the transmission at a typical facility. -400 Generation or distribution damaged materials, retooling -600 system 10 and scrap. In addition, Events per Year End sags can cause: increased Users operating costs, the need Definition of Voltage Sag 10 Transmission 6 for product reworks, safety A voltage sag is a sudden, Distribution 10 hazards, equipment damage momentary decrease in 5 and/or failure, reduced supply voltage. It can last 2. Creates a sag 4 product quality, increased from a cycle to several Feeder event for all Breakers users on the 3 10 clean-up, additional labor seconds. Voltage sags are End system costs, increased scrap most often caused by faults User 2 10 material and costs associated on the electrical transmission 1 End User or distribution system. They 0 with investigations into – 70 50 5 the problem. can be caused by lightning – 10 2 1 – 40 10 – – 10 strikes, animal contact, 20 10 6 starting of large motors 10 or an internal fault within a customer’s facility. 10 10

26 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.3 Power Conditioning Products

Application Description Features, Benefits and Functions 10 Industries and Applications Sag Correction Using the SRT Continuous Regulation Affected by Sags The SRT is a high The Sag Ride Through is an 10 Key industries: Equipment or processes: performance, inverter- active voltage conditioner. based voltage conditioning This means it will constantly ● Semi-conductor ● Manufacturing process 10 device developed to provide respond to voltage sags and manufacturers controllers protection to sensitive loads swells in the +/–10% range ● ● 10 Communications Variable speed drives against commonly occurring with a regulated output in the ● Steel mills ● Robotics voltage sags. +/–1% range. The SRT can be ● Petroleum and chemical ● Motor conductor applied to the main service 10 The SRT monitors the processing ● entrance, at branch locations Telephone systems incoming supply voltage and ● or in front critical loads. The 10 Health care ● HID lighting when it deviates from the SRT provides an outstanding ● Paper mills ● HVAC controls nominal voltage level, the return on investment. It 10 ● Automotives ● Medical equipment SRT achieves voltage delivers operation productivity ● conditioning by injecting the Textile ● Computers that is just not possible with appropriate correction voltage 10 ● Printing traditional tap switching or in series with the power ferroresonant technologies. ● Plastics supply. The SRT provides an The SRT consists of a voltage 10 ● Other manufacturing extremely fast reaction time source inverter, bypass circuit and subcycle response to sag and an injection transformer 10 events that would otherwise Block Diagram of the SRT Active Voltage Conditioner connected in series between cause loads to drop out. the incoming utility supply 10 The SRT is designed for low and the load, as shown in voltage systems (600 to 208, the figure below. For the 10 three-phase) and is also standard sag correcting offered in medium voltage model, the injection 3-Phase Compensating applications from 25 kVA transformer consists of a 10 Voltage boost component. The SRT Secondary to 4 MVA. Installation is 3-Phase 3-Phase simple and the SRT monitors the incoming supply 10 Utility Injection Load provides customers with voltage and when it deviates Supply Distribution Primary Transformer Voltage from the nominal voltage Transformer a new solution to improve 10 productivity and reduce level the SRT inserts an appropriate compensating Bypass Circuit downtime for sag related 10 SRT Input problems. voltage using the IGBT SRT Output inverter and series injection The SRT meets the transformer. Energy is 10 Voltage Source stringent requirements sourced from the supply Inverter of the Semi-F47 standard; during this time. This 10 a key requirement for SAG regulates the load voltage correction in the semi- to its nominal value, conductor industry. thus eliminating voltage 10 disturbances from the utility ● Complete correction supply affecting the load. 10 of single-phase voltage sags down to 63% for 30 seconds 10 ● Partial correction of three- phase sags down to 50% 10 for 30 seconds ● Correction of utility voltage 10 unbalance (from network side of transformer) 10 ● Attenuation of voltage flicker 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 27 10.3 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Conditioning Products

10 Catalog Number Selection 10 SRT2 10 SRT2 1200 480 A A – TC

10 Load kVA, 30% Load kVA, 40% Options 0200 0600 1500 0150 0600 1500 Voltage Frequency Correction Blank = None 10 0225 0800 2000 0225 0750 1800 208 A = 60 Hz A = 40% (+10/–40%) TC = Terminal cabinet 0300 1000 2400 0300 0900 480 B = 50 Hz B = 30% (+10/–30%) 0400 1200 0450 1200 600 C = 15% (+10/–15%) 10 Three-phase/three-wire 10 SRT (30% Correction) SRTS (40% Correction) 10 SRT 0075 480 A A SRT 0050 480 A A 10

Model Bypass Model Bypass 10 Load Voltage Frequency A = No Load Voltage Frequency A = No kVA 208 A = 60 Hz B = Yes kVA 208 A = 60 Hz B = Yes 10 0025 480 B = 50 Hz 0017 480 B = 50 Hz 0050 600 0033 600 0075 Three-phase/ 0050 Three-phase/ 10 three-wire three-wire

Notes 10 For 50% Hz international applications, consult factory. For 15% correction, consult factory. 10 Optional mechanical bypass, refer to factory for details. For 50 Hz international applications, consult factory. 10 Terminal cabinet required on all units 200 kVA and larger except when a bypass is required. 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

28 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.3 Power Conditioning Products

Technical Data and Specifications 10 SRT Specifications 10 Description Specifications Load Capacity 10 Capacity (kVA) 25 kVA to 50 MVA (as specified per model) Displacement power factor of connected load 0–1, leading or lagging 10 Crest factor for rated kVA 2.0 at 100% of rated load for continuous operation (including up to 10% voltage correction) Overload—30 seconds 150% with up to 10% of voltage correction 10 Input Supply 10 Nominal supply voltage 208/480/600V, 60 Hz three-phase, three-wire plus ground (higher system voltages supplied to requirement up to 36 kV) Maximum supply voltage 110% of nominal supply voltage 10 Minimum three-phase supply voltage Running 50% of nominal supply voltage 10

Starting 75% of nominal supply voltage 10 Minimum single-phase-to-ground supply voltage Running 25% of nominal supply voltage 10 Starting 63% of nominal supply voltage Efficiency of system 98–99% 10 Output Supply Nominal voltage (V) 208/480/600V, 60 Hz; three-phase, three-wire plus ground (higher system voltages supplied to requirement) 10 Three-phase balanced correction +30% for at least 30 seconds for 100% correction 10 Single-phase-to-ground correction +45% for at least 30 seconds; +10% continuous three-phase correction (all models). Consult factory for specialist correction requirements. Voltage regulation ±1% up to 10% continuous three-phase correction ±2.5% at 30% three-phase correction 10 Response (to sag event) Initial sag correction applied within 1 ms, remainder over the next cycle Response to swell event ±1% up to a 10% continuous three-phase correction with initial swell correction applied within 1 ms, remainder over the next cycle 10 (SRT2 models only) Bypass 10 Nominal power SRT rating (kVA) Maximum overload capacity (in bypass): 10 For 10 minutes (%) 125 10 For 1 minute (%) 150 For 600 milliseconds (%) 700 10 For 100 milliseconds (%) 1000 Transfer time 10 Inverter to bypass (ms) <0.5 Bypass to inverter (ms) <40–750 10 Environmental 10 Operating temperature 32°F to 104°F (0 to 40°C); 122°F (50°C) maximum with 20% load derating Cooling Forced ventilation 10 Capacity derating with elevation –1.2% every 100m above 1000m Humidity <95%, noncondensing 10 Warranty 1 year 10 Notes If SRT has tripped (offline) due to below threshold input voltages, it cannot be restarted until the system voltage is at least this % of the nominal. 10 Single-phase-to-ground fault occurring on the utility side of a delta-wye distribution transformer. The SRT provides continuous correction and only transitions to and from bypass when manually starting and stopping or under fault or overload conditions. The transition from bypass to inverter takes up to 750 ms. The autoresettable bypass mode of operation includes an additional 5-second delay allowing time for the fault to clear. 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 29 10.3 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Conditioning Products

10

10 System Capacities Load Capacity at Normal Fault System System Dissipation Airflow 10 Model Number Voltage 480V (kVA) Capacity (kVA) Efficiency (%) (Worst Case) (kW) (mm3/min) 10 40% Correction SRT20150480AA 150 40 97.55 3.8 18 10 SRT20225480AA 225 40 97.77 5.2 18 SRT20300480AA 300 40 98.00 6.1 18 10 SRT20450480AA 450 40 98.22 8.0 36 10 SRT20600480AA 600 40 98.44 9.8 36 SRT20750480AA 750 40 98.44 12.2 54 10 SRT20900480AA 900 40 98.55 13.2 54 SRT21200480AA 1200 40 98.55 18.1 72 10 SRT21500480AA 1500 50 98.77 20.22 90 SRT21800480AA 1800 50 98.88 22.11 108 10 30% Correction 10 SRT20150480AB 150 40 98.55 2.85 18 SRT20200480AB 200 40 98.55 3.80 18 10 SRT20225480AB 225 40 98.66 4.30 18 SRT20300480AB 300 40 98.66 5.20 18 10 SRT20400480AB 400 40 98.88 6.10 18 SRT20600480AB 600 40 99.00 8.00 36 10 SRT20800480AB 800 40 99.11 9.80 36 10 SRT21000480AB 1000 40 99.11 12.20 54 SRT21200480AB 1200 40 99.33 13.20 54 10 SRT21500480AB 1500 40 99.22 18.10 72 SRT22000480AB 2000 50 99.33 20.20 90 10 SRT22400480AB 2400 50 99.44 22.11 108 10 10 10 10 10 10 10 10 10 10 10 10 10

30 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.3 Power Conditioning Products

Dimensions Approximate Dimensions in Inches (mm) 10

SRT2, SRT and SRTS 10 Cabinet Dimensions 10 Model Number Height Width Depth SRT2 40% Correction 10 SRT20150480AA 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) SRT20225480AA 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 10 SRT20300480AA 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 10 SRT20450480AA 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) SRT20600480AA 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 10 SRT20750480AA 85.00 (2159.0) 96.00 (2438.4) 96.00 (2438.4) SRT20900480AA 85.00 (2159.0) 96.00 (2438.4) 96.00 (2438.4) 10 SRT21200480AA 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) SRT21500480AA 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) 10 SRT21800480AA 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) 10 SRT2 30% Correction SRT20150480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 10 SRT20200480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) SRT20225480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 10 SRT20300480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) SRT20400480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 10 SRT20600480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 10 SRT20800480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) SRT21000480AB 85.00 (2159.0) 96.00 (2438.4) 32.00 (812.8) 10 SRT21200480AB 85.00 (2159.0) 96.00 (2438.4) 32.00 (812.8) SRT21500480AB 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) 10 SRT22000480AB 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) SRT22400480AB 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) 10 SRT/SRTS 40% Correction 10 SRTS17480AA 24.00 (609.6) 24.00 (609.6) 36.00 (914.4) SRTS30480AA 24.00 (609.6) 24.00 (609.6) 36.00 (914.4) 10 SRTS50480AA 24.00 (609.6) 24.00 (609.6) 36.00 (914.4) SRT/SRTS 30% Correction 10 SRT25408AB 24.00 (609.6) 24.00 (609.6) 36.00 (914.4) 10 SRT50408AB 24.00 (609.6) 24.00 (609.6) 36.00 (914.4) SRT75408AB 24.00 (609.6) 24.00 (609.6) 36.00 (914.4) 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 31 10.3 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Conditioning Products

10 Electronic Voltage Regulator (EVR) Tap Changer Contents Description Page 10 Sag Ride Through (SRT) ...... 26 Electronic Voltage Regulator (EVR) (EVR) 10 Catalog Number Selection ...... 33 Technical Data and Specifications ...... 33 10 10 10 10 10 10

10

10 Electronic Voltage Regulator (EVR) 10 Product Description Features and Benefits Eaton’s Electronic Voltage Brownouts The Solution ● Coordinated with standard 10 Regulator (EVR) is the ideal In the United States, most Prior to installing an expensive thermal-magnetic breakers solution for keeping your facilities have sufficient solution, Eaton encourages to allow motor starts 10 facility and equipment up and voltage regulation. However, customers to monitor ● Optional 100 kA per phase running during brownouts, in some U.S. locations and incoming voltage to surge protection undervoltage conditions and 10 many developing countries, determine if voltage ● Input frequency range other power problems. The regulation problems occur regulation is a problem. operation from 57–63 Hz EVR can significantly reduce because of overstressed The local utility may also be ● Not affected by load power 10 the costs of equipment utility distribution systems. able to provide information factor. Can operate damage and downtime on voltage expected at effectively in low-load 10 when these situations occur. In some cases, due to the the facility. The state-of-the-art design excessive demand on the applications due to provides rapid response time, utility system, voltage may Using a meter, it can quickly “unique leakage 10 high efficiency, high inrush be below 10% of nominal be determined if a voltage reactance” technology current capability, and (–10%) during the day. This regulation problem or ● Fail-safe bypass circuit, 10 operating advantages condition is called a voltage brownout condition exists. isolation transformer exclusive to Eaton. regulation or brownout. The appropriate solution and overtemperature Customers may notice dim would be an EVR. EVRs can protection 10 The EVR maintains a tightly lights and reduced power. be installed at the service ● Less than 1% THD regulated output voltage by During the evening, voltage entrance, branch panel or ● Monitoring panel displays 10 automatically activating the may rise above 10% of at critical loads. rms metering, output appropriate transformer tap nominal (+10%) because voltage and current, kVA, 10 through a silicone controlled large facilities and loads are Eaton’s EVR is a solid-state under- and overvoltage, rectifier (SCR). Tap changer shut down. This shutdown tap changing power phase rotation, phase loss, response time is initiated at reduces the power demand conditioner designed to 10 first and second stage one cycle, ensuring rapid on the grid and results in a protect against brownouts temperature alarm, shut- and precise regulation. voltage increase. and long duration voltage 10 Switching at zero current regulation problems. off, EPO tripped and eight enables noise reduction The IEEE defines voltage optional external ports 10 during tap transitions. regulation as overvoltage or undervoltage. Voltage 10 regulation events last from a few minutes to many hours with voltage varying 10 by ±20%. Long-term regulation problems differ 10 from short duration sags and dips, which are much deeper 10 voltage drops. 10

32 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.3 Power Conditioning Products

Catalog Number Selection 10 EVR 10 EVR 025 208D 400Y B S M1 10

kVA Ratings and Dimensions Options 10 Weight Dimensions in Inches (mm) M1 = IQ 110 Meter kVA Lbs (kg) BTUs/hr (W x D x H) M2 = IQ 260 Meter B = Bypass 10 010 440 (199.8) 1705 21.00 x 29.00 x 30.00 (533.4 x 736.6 x 762.0) Nominal Output Voltage 015 520 (236.1) 2557 21.00 x 29.00 x 30.00 (533.4 x 736.6 x 762.0) Nominal Input Voltage (Wye Output: L, L, L, N, G) Surge Protection 025 700 (317.8) 2560 21.00 x 29.00 x 44.00 (533.4 x 736.6 x 1117.6) (Delta Input: L, L, L, G) 208Y = 120/208 10 X = No 030 720 (326.9) 3090 21.00 x 29.00 x 44.00 (533.4 x 736.6 x 1117.6) 208D = 208D 400Y = 230/400 S = Yes 045 950 (431.3) 4600 45.00 x 29.00 x 44.00 (1143.0 x 736.6 x 1117.6) 240D = 240D 480Y = 277/480 10 050 950 (431.3) 5525 45.00 x 29.00 x 44.00 (1143.0 x 736.6 x 1117.6) 400D = 400D 600Y = 347/600 075 1100 (499.4) 12,787 45.00 x 29.00 x 44.00 (1143.0 x 736.6 x 1117.6) 480D = 480D Frequency 100 1660 (753.6) 17,050 45.00 x 29.00 x 44.00 (1143.0 x 736.6 x 1117.6) 600D = 600D A = 60 Hz 10 125 1980 (898.9) 21,312 45.00 x 29.00 x 44.00 (1143.0 x 736.6 x 1117.6) B = 50 Hz 150 2200 (998.8) 25,575 45.00 x 29.00 x 44.00 (1143.0 x 736.6 x 1117.6) 10 225 3300 (1498.2) 23,000 56.00 x 41.50 x 77.00 (1422.4 x 1054.1 x 1955.8) 300 4000 (1816.0) 30,750 56.00 x 41.50 x 77.00 (1422.4 x 1054.1 x 1955.8) 500 5500 (2497.0) 51,250 72.00 x 48.50 x 77.00 (1828.8 x 1231.9 x 1955.8) 10 10 Technical Data and Specifications 10 EVR Specification (10 to 1250 kVA) Feature Description 10 Technology Electronic tap changer 10 Input voltages 240–600 Vac; three-phase (three-wire) Input voltage range +10/–23% 10 Output voltage range ± 3% typical Response time One cycle, zero current switching 10 Frequency 60 Hz standard (other frequencies available) 10 Efficiency 96% at full load, 98.5% at light loads Minimum load None 10 Inrush current capabilities 1000% for one cycle; 200% for 10 seconds; or as limited by upstream overcurrent protection Noise attenuation 10 Common mode –120 dB at 100 kHz Normal mode –40 dB at 100 kHz 10 Monitoring (option) Refer to “Features and Benefits” for details Bypass panel Optional (10–45 kVA), standard (50–500 kVA) 10 Front access panel 50–150 kVA standard 10 Surge protection device (option) 100 kA per phase Operating temperature 32°F to 122°F (0 to 50°C) 10 Altitude Up to 7000 ft (2134m) Standard warranty 12/18 months 10 Extended warranty (startup service) 12/18 months factory on-site warranty 10 Notes All weights are approximate. Monitor option includes main input circuit breaker. Refer to PAD for pricing and availability. 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 33 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 Capacitor Cell With M12 Threaded Mounting Bolt, Washer, Nut Contents Description Page 10 Product Overview Product Selection ...... 35 10 Dimensions ...... 36 UNIPUMP...... 37 10 UNIPAK ...... 40 AUTOVAR 300 Automatic Power Factor Correction 10 Capacitor Systems...... 51 AUTOVAR 600 Automatic Power Factor Correction 10 Capacitor Systems...... 54 AUTOVAR Filter—LV Automatic Harmonic Filter ...... 59 10 Transient-Free Static Switching Power Factor Correction Units...... 63 10 Active-Harmonic Filter-Harmonic Correction Unit— NEMA 1 Enclosure ...... 67 10

10

10 Product Overview 10 Product Description Eaton’s power factor There are several reasons When capacity becomes a Harmonic Filtering 10 correction capacitors and to correct poor power factor. problem, the choice of a As the world becomes more harmonic filters are an The first is to reduce or solution will be dependent dependent on electric and 10 essential part of modern eliminate a power factor upon the size of the increase electronic equipment, the systems. penalty charged by the utility. needed. Like all power likelihood that the negative Power factor correction Another reason is that your quality solutions, there impact of harmonic distortion 10 capacitors are the simplest existing transformer is, or are many factors that need increases dramatically. The and most economical shortly will be, at full capacity to be considered when efficiency and productivity 10 means of increasing the and installing power factor determining which solution gains from these increasingly capacity of any power correction capacitors can will be best to solve your sophisticated pieces of 10 system, minimizing energy be a very cost-effective power factor problem. equipment have a negative losses and correcting load solution to installing a brand side effect…increased 10 power factor. In addition, new service. Depending on harmonic distortion in the power factor penalties can the amount of power factor power lines. The difficult be reduced and power quality correction (kVAR that needs thing about harmonic 10 can be greatly enhanced. to be injected into the distortion is determining the electrical system to improve cause. Once this has been 10 the power factor) and the determined, the solution dynamic nature of the load, can be easy. Passive and 10 a fixed or switched capacitor active harmonic filtering bank may be the best equipment will mitigate 10 solution. specific harmonic issues, and correct poor power 10 factor as well. 10 10 10 10 10 10 10

34 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Product Selection 10 1543PCRMA Capacitor Cell Chart Harmonic Rated Capacitor Cell Chart 10 Voltage kVAR Part Number Voltage kVAR Part Number 240 1.5 643PCRMA 240 12.5 12X23PHRMA 10 240 2 8B43PCRMA 480 15.0 1543PHRMA 240 2.5 1043PCRMA 480 25.0 2543PHRMA 10 240 3 12X43PCRMA 600 12.3 12A63PHRMA 240 4 423PCRMA 600 14.7 14S63PHRMA 10 240 5 2043PCRMA 600 16.7 16S63PHRMA 10 240 6.3 6B23PCRMA Note 240 7.5 7X23PCRMA kVAR rating standard. NEMA kVAR tolerance is +15% to 0%. Part number shown is for 10 three-phase units. Up to 5 kVAR at 480V—fast-on terminals are standard. Above 5 kVAR at 480V 240 8.3 8B23PCRMA (and on all other voltages)—sigut terminals are standard. For dimensions and weights, 240 10 1023PCRMA see following page. 10 240 12.5 12X23PCRMA 10 240 15 1523PCRMA 240 16.7 16S23PCRMA 10 240 17.5 17X23PCRMA 480 1.5 1X43PCRMA 10 480 2 243PCRMA 480 2.5 2X43PCRMA 10 480 3 343PCRMA 10 480 4 443PCRMA 480 5 543PCRMA 10 480 6 643PCRMA 480 7.5 7X43PCRMA 10 480 8.3 8B43PCRMA 480 9 943PCRMA 10 480 10 1043PCRMA 10 480 12.5 12X43PCRMA 480 15 1543PCRMA 10 480 18 1843PCRMA 480 20 2043PCRMA 10 480 25 2543PCRMA 10 480 30 3043PCRMA 600 5 563PCRMA 10 600 7.5 7X63PCRMA 600 10 1063PCRMA 10 600 12.5 12X63PCRMA 600 15 1563PCRMA 10 600 17.5 2063PCRMA 10 600 20 2563PCRMA 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 35 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

Dimensions 10 Approximate Dimensions in Inches (mm)

10 Capacitor Cell Chart Harmonic Rated Capacitor Cell Chart 10 Part Number Depth Height Weight in Lbs (kg) Part Number Depth Height Weight in Lbs (kg) 643PCRMA 3.10 (78.7) 7.90 (200.7) 1.1 (0.5) 12X23PHRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 10 8B43PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 1543PHRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 1043PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 2543PHRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 10 12X43PCRMA 3.50 (88.9) 9.40 (238.8) 1.8 (0.8) 12A63PHRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 10 423PCRMA 3.10 (78.7) 7.90 (200.7) 1.1 (0.5) 14S63PHRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 2043PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 16S63PHRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 10 6B23PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 7X23PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) Capacitor Cell 10 8B23PCRMA 3.50 (88.9) 9.40 (238.8) 1.8 (0.8) 1023PCRMA 3.50 (88.9) 9.40 (238.8) 1.3 (0.6) 10 12X23PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 10 1523PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 16S23PCRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 10 17X23PCRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 1X43PCRMA 2.10 (53.3) 5.00 (127.0) 0.7 (0.3) Height 10 243PCRMA 2.50 (63.5) 5.50 (139.7) 0.9 (0.4) 10 2X43PCRMA 2.50 (63.5) 5.50 (139.7) 0.9 (0.4) 343PCRMA 2.50 (63.5) 5.50 (139.7) 0.9 (0.4) 10 443PCRMA 2.50 (63.5) 6.50 (165.1) 0.9 (0.4) 543PCRMA 2.50 (63.5) 6.50 (165.1) 0.9 (0.4) 10 643PCRMA 3.10 (78.7) 7.90 (200.7) 1.1 (0.5) M12 7X43PCRMA 3.10 (78.7) 7.90 (200.7) 1.1 (0.5) 16+1 10 8B43PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 10 943PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 1043PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) Depth 10 12X43PCRMA 3.50 (88.9) 9.40 (238.8) 1.8 (0.8) 1543PCRMA 3.50 (88.9) 9.40 (238.8) 1.8 (0.8) 10 1843PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 2043PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 10 2543PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 10 3043PCRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 563PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 10 7X63PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 1063PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 10 12X63PCRMA 3.50 (88.9) 9.40 (238.8) 1.8 (0.8) 10 1563PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 2063PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 10 2563PCRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 10 10 10 10 10

36 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

UNIPUMP Contents 10 Description Page Product Overview...... 34 10 UNIPUMP Product Selection ...... 38 10 Dimensions ...... 39 UNIPAK...... 40 10 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems ...... 51 10 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems ...... 54 10 AUTOVAR Filter—LV Automatic Harmonic Filter ...... 59 Transient-Free Static Switching Power Factor 10 Correction Units ...... 63 Active-Harmonic Filter-Harmonic Correction Unit— 10 NEMA 1 Enclosure...... 67 10

10

UNIPUMP 10 Product Description Features, Benefits and Functions 10 Non-fused capacitors for outdoor irrigation and oil field Configuration ● Design: Self-healing ● Ceramic discharge 10 installations. ● Outer case: Heavy, No. 14 metallized high crystalline : Reduce residual gauge steel finished with polypropylene with ramp voltage to less than 50 volts ● Designed expressly for durable powder coat finish. metallization film. Total within one minute of 10 outdoor pumping Integral strap mounting losses less than 0.45 watt de-energization. Selected applications bracket with keyhole at top per kVAR. (Dielectric for 20-year nominal life. 10 ● Pole or wall mounting for pole or wall installation. losses less than 0.2 watt Exceeds NEC requirements ● Small, light-weight No knockouts per kVAR) ● Capacitor operating 10 enclosure for easy ● Ramp metallization: temperature: -40°F installation Capacitor Cells Provides thicker film at (–40°C) to +115°F (+46°C) 10 ● SO-WA type flexible cable ● Terminals: Insulated higher current density ● Case: Weatherproof facilitates installation finger-safe terminals rated areas, allowing for reduced aluminum housing internal losses, lower 10 (4-conductor) for 3 kVAC withstand ● Warranty: The longest operating temperatures ● Gland-type weatherproof ● Dielectric fill: Dry-type in the industry—five full and longer life expectancy. 10 bushings cells utilize soft organic years of warranty on Also prevents chain ● polymer resin—Resinol capacitor cells Strong outer case reaction breakdown by ● Eliminates potential for 10 Application Description limiting propagation of Standards and Certifications corona/partial discharge/ film vaporization Outdoor irrigation and oil electrochemical oxidation ● UL and CSA listed 10 ● Pressure sensitive and gas field pumping. ● Excellent heat dissipation interrupter: Built-in, three- ● Flash point: +444°F phase pop-up interrupter 10 (+229°C) design. UL recognized. ● Fire point: +840°F Removes capacitor from 10 (+449°C) line before internal pressure can cause case 10 rupture. Bulged capacitor cell top provides easy 10 visual indication of interrupter operation 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 37 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 Product Selection 10 UNIPUMP UNIPUMP Rated Case Cable Shipping Weight Catalog 10 kVAR Current Size Size in Lbs (kg) Number 10 240 Vac 2 4.8 AA 14.0 10.0 (4.5) 223JMR 10 2.5 6.0 AA 14.0 10.0 (4.5) 2X23JMR 3 7.2 AA 14.0 10.0 (4.5) 323JMR 10 4 9.6 AA 14.0 11.0 (5.0) 423JMR 5 12.0 AA 14.0 11.0 (5.0) 523JMR 10 6 14.4 BB 12.0 15.0 (6.8) 623JMR 10 7.5 18.0 BB 12.0 15.0 (6.8) 7X23JMR 480 Vac 10 2 2.4 AA 14.0 10.4 (4.7) 243JMR 2.5 3.0 AA 14.0 10.4 (4.7) 2X43JMR 10 3 3.6 AA 14.0 10.4 (4.7) 343JMR 10 4 4.8 AA 14.0 10.4 (4.7) 443JMR 5 6.0 AA 14.0 10.4 (4.7) 543JMR 10 6 7.2 AA 14.0 10.6 (4.8) 643JMR 7.5 9.0 AA 14.0 10.6 (4.8) 7X43JMR 10 10 12.0 AA 14.0 10.8 (4.9) 1043JMR 12.5 15.0 BB 12.0 15.0 (6.8) 12X43JMR 10 15 18.0 BB 12.0 15.0 (6.8) 1543JMR 10 17.5 21.0 BB 8.0 15.8 (7.2) 17X43JMR 20 24.0 BB 8.0 16.8 (7.6) 2043JMR 10 25 30.0 BB 8.0 16.8 (7.6) 2543JMR 600 Vac 10 5 4.9 AA 14.0 10.8 (4.9) 563JMR 7.5 7.4 AA 14.0 10.8 (4.9) 7X63JMR 10 10 9.8 AA 14.0 10.8 (4.9) 1063JMR 10 12.5 12.3 AA 12.0 15.0 (6.8) 12X63JMR 15 14.7 BB 12.0 15.8 (7.2) 1563JMR 10 17.5 17.2 BB 8.0 16.8 (7.6) 17X63JMR 20 19.6 BB 8.0 16.8 (7.6) 2063JMR 10 10 10 10 10 10 10 10 10 10

38 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Dimensions Approximate Dimensions in Inches (mm) 10

UNIPUMP UNIPUMP Dimension Chart 10 Ø 0.44 Size Code A B C D 10 (11.2) AA 11.00 (279.4) 14.20 (360.7) 12.60 (320.0) 13.20 (335.3) Ø 0.88 1.84 (22.4) BB 14.00 (355.6) 17.10 (434.3) 15.50 (393.7) 16.10 (408.9) (46.7) 10

1.75 10 (44.5) 10 10 10

D C A 10 10 10 10 1.45 (36.8) 10 0.50 0.75 Ø 0.44 (12.7) (19.1) (11.2) 10 1.50 (38.1) 10 5.15 (130.8) 0.07 10 (1.8) 1.55 (39.4) 10 2.56 (65.0) 1.98 10 (50.3) 10 10 B 10 10 10

1.75 10 (44.5) 5.00 (127.0) 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 39 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 UNIPAK Contents Description Page 10 Product Overview ...... 34 UNIPUMP...... 37 10 UNIPAK Features, Benefits and Functions ...... 41 10 Standards and Certifications ...... 41 Product Selection ...... 42 10 Dimensions ...... 49 AUTOVAR 300 Automatic Power Factor Correction 10 Capacitor Systems...... 51 AUTOVAR 600 Automatic Power Factor Correction 10 Capacitor Systems...... 54 AUTOVAR Filter—LV Automatic Harmonic Filter ...... 59 10 Transient-Free Static Switching Power Factor Correction Units...... 63 10 Active-Harmonic Filter-Harmonic Correction Unit— NEMA 1 Enclosure ...... 67 10

10 UNIPAK 10 Product Description Application Description Designed for power factor 10 UNIPAK Filter— Harmonic Rated Capacitor Cells correction in plants Harmonic Filtering ● Standard voltage rated experiencing harmonics Harmonic filter systems for capacitor cells designed for problems due to high 10 low voltage, heavy-duty higher dielectric strength amounts of nonlinear loads. applications. and with added ability to 10 withstand stress caused ● Reduce harmonics and by dv/dt voltage transients correct power factor 10 caused by harmonics ● Tuned for maximum ● Better suited for harmonic efficiency in reducing applications than higher 10 harmonic currents voltage rated cells associated with nonlinear 10 load environments (such UNIPAK with Harmonic Rated UNIPAK with Optional Air Filter as VFDs) Capacitor Cells ● 10 Two-enclosure design ● Standard capacitor isolates capacitors from systems utilizing harmonic 10 high-temperature operating rated capacitor cells reactors, and allows for ● For use in moderate flexible installation 10 harmonic environments ● Twenty-year life design where engineering 10 ● Five-year cell warranty/ supervision allows in place one-year reactor warranty of harmonic filter designs 10 ● Three-phase cell capacitor ● Provides future conversion construction. Three-phase capability into a harmonic interrupter system filter design due to facility 10 growth or increased 10 nonlinear load levels 10 10 10 10 10

40 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Features, Benefits and Functions ● Five-year warranty ● Cover: “L” shaped Capacitor cells ● Capacitor operating 10 on capacitor cells gasketed cover with ● Terminals: Insulated temperature: -40°F (-40°C) ● Designed for heavy-duty multiple fasteners provides finger-safe terminals rated to +115°F (+46°C) 10 applications front opening for ease of for 3 kVAC withstand ● Case: Weatherproof installation and service ● Twenty-year life design ● Dielectric fill: Dry-type aluminum housing 10 ● Ground terminal: ● ● Indoor/outdoor service cells utilize soft organic Warranty: The longest Furnished inside case polymer resin—Resinol in the industry—five full ● Wall (up to 180 kVAR) 10 ● and floor-mounted Power terminal lugs: ● Eliminates potential for years of warranty on units available Large size provided for corona/partial discharge/ capacitor cells 10 easy connection electrochemical ● Fuse protection standard ● Fusing: oxidation Reactors ● 10 Blown-fuse indicating ● ● ● Tuning: Tuned to 4.7 lights standard Size Code A1: Three Excellent heat midget-type fuses dissipation harmonic order ● 10 Quick lead-times ● with 100,000 ampere ● Flash point: +444°F Detuning: Reactor ● Harmonic filters available interrupting capacity (+229°C) designs can be detuned ● ● upon request to 4.2nd to 10 Slim profile allows reduced Size Code A2 and ● Fire point: +840°F protect capacitors against footprint, conserving larger: Three slotted- (+449°C) valuable floor space blade type fuses with alternate harmonics 10 ● New capacitor 200,000 ampere ● Design: Self-healing ● Construction: 100% configuration leads interrupting capacity; metallized high crystalline copper windings for cool 10 to cooler operating Fuses mounted on polypropylene with ramp operating temperatures; conditions, extending stand-off bushings or metallization film. Total designed operating 10 capacitor life fuse blocks; solderless losses less than 0.45 watt temperature rise less connectors for easy per kVAR. (Dielectric than 80ºC. Open frame Configuration hookup of incoming line losses less than 0.2 watt construction with 220ºC 10 ● Outer case: Heavy, No. 14 conductors per kVAR) insulation system gauge steel finished with ● Fuse indicating lights: ● Ramp metallization: ● Thermal sensors: One 10 durable powder coat finish. Red, neon blown-fuse Provides thicker film at per phase, self-resetting Wall mounting flanges indicating lights are higher current density thermistors provide 10 and floor mounting feet. protected by transparent areas, allowing for reduced reactor over-temperature Elimination of knockouts weatherproof guard internal losses, lower protection and indication 10 permits indoor/outdoor operating temperatures ● Reactor indicating light: ● Options: use. Manufactured to and longer life expectancy. Thermal overload ● 10 NEMA requirements 1, No fuses Also prevents chain indicating light activates 3R and 12 ● Air filters for units reaction breakdown by when reactor temperature 10 ● Elevated floor mounting with enclosure limiting propagation of reaches 180ºC film vaporization feet allow access for sizes C2, D1 and E1 ● Warranty: One-year easy maintenance ● Pressure sensitive replacement of reactors 10 Note: NEMA 12 enclosure interrupter: Built-in, three- standard for enclosure sizes phase pop-up interrupter Standards and Certifications 10 A1 to C1. design. UL recognized. ● UL and CSA listed Removes capacitor from 10 line before internal pressure can cause case rupture. Bulged capacitor 10 cell top provides easy visual indication of 10 interrupter operation ● Ceramic discharge 10 resistors: Reduce residual voltage to less than 50 volts 10 within one minute of de-energization. Selected for 20-year nominal life. 10 Exceeds NEC requirements 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 41 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 Product Selection UNIPAK Low Voltage Fixed Capacitor Banks 10

10 UNIPAK 240 Vac UNIPAK Rated Shipping Weight Part 10 kVAR Current Enclosure in Lbs (kg) Number 1 2.4 A1 18 (8) 123PMURF 10 1.5 3.6 A1 18 (8) 1X23PMURF 10 2 4.8 A1 19 (9) 223PMURF 2.5 6 A1 19 (9) 2X23PMURF 10 3 7.2 A1 19 (9) 323PMURF 4 9.6 A1 20 (9) 423PMURF 10 512A2 29 (13) 523PMURF 6 14.4 A2 29 (13) 623PMURF 10 7.5 18 A2 30 (14) 7X23PMURF 10 8 19.2 A2 31 (14) 823PMURF 10 24 A2 31 (14) 1023PMURF 10 12.5 30 A2 32 (14) 12X23PMURF 15 36 A2 33 (15) 1523PMURF 10 17.5 42 B1 44 (20) 17X23PMURF 20 48 B1 45 (20) 2023PMURF 10 22.5 54 B1 46 (21) 22X23PMURF 10 25 60 B1 46 (21) 2523PMURF 30 72 B1 47 (21) 3023PMURF 10 32.5 78 B1 47 (22) 32X23PMURF 35 84 B1 48 (22) 3523PMURF 10 40 96 C1 64 (29) 4023PMURF 10 42.5 102 C1 65 (30) 42X23PMURF 45 108 C1 66 (30) 4523PMURF 10 50 120 C1 68 (31) 5023PMURF 60 144 C1 69 (31) 6023PMURF 10 70 168 C2 99 (45) 7023PMURF 75 180 C2 100 (46) 7523PMURF 10 80 192 C2 101 (46) 8023PMURF 10 90 216 C2 103 (47) 9023PMURF 100 240 C2 104 (47) 10023PMURF 10 120 288 D1 133 (60) 12023PMURF 140 336 D1 137 (62) 14023PMURF 10 150 360 D1 140 (64) 15023PMURF 160 384 E1 175 (80) 16023PMURF 10 180 432 E1 182 (83) 18023PMURF 10 200 480 E1 189 (86) 20023PMURF Notes 10 Multiply the 240 Vac kVAR rating by 0.75 to calculate the kVAR value at 208 Vac. Fused with blown-fuse indication available standard. Non-fused and no lights also available—please consult the factory. 10 Other ratings available, consult factory. For dimensional information, refer to Page 49. 10 Part Numbers: PMURF—three fuses + three lights 10 PMURN—non-fused 10

42 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

UNIPAK 480 Vac UNIPAK Rated Shipping Weight Part 10 kVAR Enclosure Current in Lbs (kg) Number 1.5 A1 1.8 17 (8) 1X43PMURF 10 2A1 2.4 18 (8) 243PMURF 10 2.5 A1 3 18 (8) 2X43PMURF 3A1 3.6 19 (9) 343PMURF 10 4A1 4.8 19 (9) 443PMURF 5A16 19 (9) 543PMURF 10 6A1 7.2 19 (9) 643PMURF 10 7.5 A1 9 20 (9) 7X43PMURF 8A1 9.6 20 (9) 843PMURF 10 9A1 10.8 20 (9) 943PMURF 10 A1 12 20 (9) 1043PMURF 10 12.5 A2 15 29 (13) 12X43PMURF 15 A2 18 29 (13) 1543PMURF 10 17.5 A2 21 30 (14) 17X43PMURF 10 20 A2 24 31 (14) 2043PMURF 22.5 B1 27 44 (20) 22X43PMURF 10 25 A2 30 32 (15) 2543PMURF 27.5 B1 33 44 (20) 27X43PMURF 10 30 B1 36 44 (20) 3043PMURF 32.5 B1 39 45 (20) 32X43PMURF 10 35 B1 42 45 (20) 3543PMURF 10 37.5 B1 45 46 (21) 37X43PMURF 40 B1 48 46 (21) 4043PMURF 10 42.5 B1 51 47 (21) 42X43PMURF 45 B1 54 47 (22) 4543PMURF 10 50 B1 60 48 (22) 5043PMURF 10 55 B1 66 48 (22) 5543PMURF 60 B1 72 48 (22) 6043PMURF 10 65 C1 78 64 (29) 6543PMURF 70 C1 84 65 (30) 7043PMURF 10 75 C1 90 65 (30) 7543PMURF 80 C1 96 66 (30) 8043PMURF 10 85 C1 102 68 (31) 8543PMURF 10 90 C1 108 68 (31) 9043PMURF 100 C1 120 68 (31) 10043PMURF 10 120 C1 144 68 (31) 12043PMURF 125 C2 150 99 (45) 12543PMURF 10 140 C2 168 100 (46) 14043PMURF 150 C2 180 101 (46) 15043PMURF 10 160 C2 192 103 (47) 16043PMURF 10 180 C2 216 104 (47) 18043PMURF

Notes 10 Fused with blown-fuse indication available standard. Non-fused and no lights also available—please consult the factory. 10 Other ratings available, consult factory. For dimensional information, refer to Page 49. 10 Part Number PMURF—three fuses + three lights PMURN—non-fused 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 43 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

UNIPAK 480 Vac UNIPAK, continued 10 Rated Shipping Weight Part kVAR Enclosure Current in Lbs (kg) Number 10 200 D1 240 137 (62) 20043PMURF 10 225 D1 270 140 (64) 22543PMURF 250 E1 300 170 (77) 25043PMURF 10 300 E1 360 175 (80) 30043PMURF 350 E1 420 182 (83) 35043PMURF 10 400 E1 480 189 (86) 40043PMURF 10 Notes Fused with blown-fuse indication available standard. Non-fused and no lights also available—please consult the factory. 10 Other ratings available, consult factory. For dimensional information, refer to Page 49. 10 Part Number PMURF—three fuses + three lights 10 PMURN—non-fused 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

44 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

UNIPAK 600 Vac UNIPAK Rated Shipping Weight Part 10 kVAR Enclosure Current in Lbs (kg) Number 5A1 4.9 19 (9) 563PMURF 10 7.5 A1 7.4 19 (9) 7X63PMURF 10 10 A1 9.8 20 (9) 1063PMURF 12.5 A1 12.3 20 (9) 12X63PMURF 10 15 A2 14.7 29 (13) 1563PMURF 17.5 A2 17.2 29 (13) 17X63PMURF 10 20 A2 19.6 30 (14) 2063PMURF 10 22.5 B1 22.1 44 (20) 22X63PMURF 25 A2 24.5 31 (14) 2563PMURF 10 27.5 B1 27.0 44 (20) 27X63PMURF 30 B1 29.4 45 (20) 3063PMURF 10 32.5 B1 31.9 45 (20) 32X63PMURF 35 B1 34.3 46 (21) 3563PMURF 10 37.5 B1 36.8 46 (21) 37X63PMURF 10 40 B1 39.2 47 (21) 4063PMURF 42.5 B1 41.7 47 (22) 42X63PMURF 10 45 B1 44.1 48 (22) 4563PMURF 50 B1 49.0 48 (22) 5063PMURF 10 55 C1 53.9 64 (29) 5563PMURF 60 C1 58.8 64 (29) 6063PMURF 10 65 C1 63.7 65 (30) 6563PMURF 10 70 C1 68.6 65 (30) 7063PMURF 75 C1 73.5 66 (30) 7563PMURF 10 80 C1 78.4 68 (31) 8063PMURF 85 C1 83.3 68 (31) 8563PMURF 10 90 C1 88.2 68 (31) 9063PMURF 10 100 C1 98.0 68 (31) 10063PMURF 120 C2 117.6 99 (45) 12063PMURF 10 125 C2 122.5 100 (46) 12563PMURF 140 C2 137.2 101 (46) 14063PMURF 10 150 C2 147.0 103 (47) 15063PMURF 160 D1 156.8 135 (61) 16063PMURF 10 180 D1 176.4 137 (62) 18063PMURF 10 200 D1 196.0 140 (64) 20063PMURF 225 D1 220.5 143 (65) 22563PMURF 10 250 E1 245.0 170 (77) 25063PMURF 300 E1 294.0 175 (80) 30063PMURF 10 350 E1 343.0 182 (83) 35063PMURF 400 E1 392.0 189 (86) 40063PMURF 10 Notes 10 Fused with blown-fuse indication available standard. Non-fused and no lights also available—please consult the factory Other ratings available, consult factory 10 For dimensional information, refer to Page 49. Part Numbers: PMURF—three fuses + three lights 10 PMURN—non-fused 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 45 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 UNIPAK—with Harmonic Cells

10 Harmonic Cells Low Voltage Fixed Capacitor Systems with Harmonic Cells Rated Case Shipping Weight Catalog 10 kVAR Current Size in Lbs (kg) Number 240V 10 15 36 B1 38.4 (17) 1523HURF 10 25 60 B1 38.4 (17) 2523HURF 30 72 C1 55.2 (25) 3023HURF 10 50 120 C1 57.6 (26) 5023HURF 60 144 C2 100.8 (46) 6023HURF 10 75 180 C2 104.4 (47) 7523HURF 10 100 240 D1 136.8 (62) 10023HURF 125 300 E1 189.6 (86) 12523HURF 10 480V 15 18 A2 25.2 (11) 1543HURF 10 25 30 B1 37.2 (17) 2543HURF 30 36 B1 38.4 (17) 3043HURF 10 50 60 B1 39.6 (18) 5043HURF 10 60 72 C1 52.8 (24) 6043HURF 75 90 C1 55.2 (25) 7543HURF 10 100 120 C1 57.6 (26) 10043HURF 125 150 C2 100.8 (46) 12543HURF 10 150 180 C2 104.4 (47) 15043HURF 200 240 D1 136.8 (62) 20043HURF 10 250 300 E1 186.0 (84) 25043HURF 10 300 360 E1 189.6 (86) 30043HURF 600V 10 15 14.7 B1 37.2 (17) 1563HURF 25 24.5 B1 38.4 (17) 2563HURF 10 30 29.4 B1 39.6 (18) 3063HURF 10 50 49 C1 55.2 (25) 5063HURF 60 58.8 C1 57.6 (26) 6063HURF 10 75 73.5 C2 100.8 (46) 7563HURF 100 98 C2 104.4 (47) 10063HURF 10 125 122.5 D1 136.8 (62) 12563HURF 150 147 D1 136.8 (62) 15063HURF 10 200 196 E1 186.0 (84) 20063HURF 10 250 245 E1 189.6 (86) 25063HURF Notes 10 Fused with blown-fuse indication standard. Other ratings available, consult factory. 10 10 10 10 10 10

46 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

UNIPAK Low Voltage Fixed Harmonic Filters 10

Harmonic Filters Fixed UNIPAK Harmonic Filters 10 Reactor Reactor Combined Rated Case Shipping Weight Cabinet Shipping Weight Shipping Weight Catalog 10 kVAR Current Size in Lbs (kg) Case Size in Lbs (kg) in Lbs (kg) Number 240V 10 15 36 B1 48.4 (22.0) R 90.0 (40.9) 138.4 (62.8) 15232HMURF 25 60 B1 48.4 (22.0) R 105.0 (47.7) 153.4 (69.6) 25232HMURF 10 30 72 C1 65.2 (29.6) R 110.0 (49.9) 175.2 (79.5) 30232HMURF 10 50 120 C1 67.6 (30.7) R 130.0 (59.0) 197.6 (89.7) 50232HMURF 60 144 C2 110.8 (50.3) R 160.0 (72.6) 270.8 (122.9) 60232HMURF 10 75 180 C2 114.4 (51.9) R 185.0 (84.0) 299.4 (135.9) 75232HMURF 100 240 D1 146.8 (66.6) R 240.0 (109.0) 386.8 (175.6) 100232HMURF 10 125 300 E1 199.6 (90.6) S 280.0 (127.1) 479.6 (217.7) 125232HMURF 150 360 E1 220.0 (99.9) S 280.0 (127.1) 500.0 (227.0) 150232HMURF 10 480V 10 15 18 A2 35.2 (16.0) R 90.0 (40.9) 125.2 (56.8) 15432HMURF 25 30 B1 47.2 (21.4) R 105.0 (47.7) 152.2 (69.1) 25432HMURF 10 30 36 B1 48.4 (22.0) R 110.0 (49.9) 158.4 (71.9) 30432HMURF 50 60 B1 49.6 (22.5) R 130.0 (59.0) 179.6 (81.5) 50432HMURF 10 60 72 C1 62.8 (28.5) R 160.0 (72.6) 222.8 (101.2) 60432HMURF 10 75 90 C1 65.2 (29.6) R 185.0 (84.0) 250.2 (113.6) 75432HMURF 100 120 C1 67.6 (30.7) R 240.0 (109.0) 307.6 (139.7) 100432HMURF 10 125 150 C2 110.8 (50.3) R 280.0 (127.1) 390.8 (177.4) 125432HMURF 150 180 C2 114.4 (51.9) S 280.0 (127.1) 394.4 (179.1) 150432HMURF 10 200 240 D1 146.8 (66.6) S 330.0 (149.8) 476.8 (216.5) 200432HMURF 250 300 E1 196.0 (89.0) T 570.0 (258.8) 766.0 (347.8) 250432HMURF 10 300 360 E1 199.6 (90.6) T 575.0 (261.1) 774.6 (351.7) 300432HMURF 10 600V 15 14.7 B1 47.2 (21.4) R 90.0 (40.9) 137.2 (62.3) 15632HMURF 10 25 24.5 B1 48.4 (22.0) R 90.0 (47.7) 153.4 (69.6) 25632HMURF 30 29.4 B1 49.6 (22.5) R 105.0 (49.9) 159.6 (72.5) 30632HMURF 10 50 49 C1 65.2 (29.6) R 110.0 (59.0) 195.2 (88.6) 50632HMURF 60 58.8 C1 67.6 (30.7) R 130.0 (72.6) 227.6 (103.3) 60632HMURF 10 75 73.5 C2 110.8 (50.3) R 160.0 (84.0) 295.8 (134.3) 75632HMURF 10 100 98 C2 114.4 (51.9) R 185.0 (109.0) 354.4 (160.9) 100632HMURF 125 122.5 D1 146.8 (66.6) S 240.0 (127.1) 426.8 (193.8) 125632HMURF 10 150 147 D1 146.8 (66.6) S 280.0 (127.1) 426.8 (193.8) 150632HMURF 200 196 E1 196.0 (89.0) T 330.0 (149.8) 526.0 (238.8) 200632HMURF 10 250 245 E1 199.6 (90.6) T 570.0 (258.8) 769.6 (349.4) 250632HMURF 10 Notes Other ratings available, consult factory. 10 Fused with blown-fuse indication standard. 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 47 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 Wiring Diagram Filter Schematic with Wiring Interconnects 10 Power Lines from Disconnect 10 Lugs 10 Fuses 10 10 Reactor 10 Lugs 10 Interconnects (Provided by Customer) ቢ 10 Lugs 10 Capacitor Bank

10 Note Refer to NEC. 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

48 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Dimensions Approximate Dimensions in Inches (mm) 10 Reactor Cabinet Reactor Cabinet 10 Case Size Height Width Depth R 24.75 (628.7) 20.00 (508.0) 18.13 (460.5) 10 S 25.00 (635.0) 24.25 (616.0) 20.25 (514.4) 10 T 31.00 (787.4) 25.00 (635.0) 32.75 (831.9) 10 10 10 Low Voltage Fixed Capacitor Banks and Fixed Harmonic Filters Case A1, A2 Case B1 10 10 10 10 10 10 10 10 10 10 10 10 10 10

UNIPAK Enclosures 10 Case Size ABDEF HL X1X2X3YZ 10 A1 5.30 (134.6) 8.50 (215.9) 3.50 (88.9) 3.80 (96.5) 10.60 (269.2) 17.30 (439.4) 6.80 (172.7) 2.00 (50.8) N/A N/A 7.70 (195.6) 7.20 (182.9) A2 6.00 (152.4) 8.50 (215.9) 5.60 (142.2) 4.50 (114.3) 13.30 (337.8) 22.30 (566.4) 6.80 (172.7) 2.30 (58.4) N/A N/A 7.70 (195.6) 7.20 (182.9) 10 B1 11.10 (281.9) 10.10 (256.5) 5.80 (147.3) 9.60 (243.8) 15.70 (398.8) 25.30 (642.6) 8.50 (215.9) 4.10 (104.1) 4.50 (114.3) N/A 9.30 (236.2) 8.80 (223.5)

Legend: 10 A= Total depth B= Total width 10 D= Height of removable front cover E= Depth of feet 10 F= Height of middle mounting hole in wall bracket H= Total height 10 L= Width without feet and brackets X= Depth between front and rear mounting holes in inches 10 Y= Width between floor mounting holes Z= Width between wall bracket mounting holes 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 49 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 Approximate Dimensions in Inches (mm) Case C1, C2 Case D1, E1 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 UNIPAK Enclosures Case 10 Size ABDEF HL X1X2X3YZ C1 10.60 (269.2) 12.10 (307.3) 7.10 (180.3) 9.10 (231.1) 16.20 (411.5) 26.30 (668.0) 10.40 (264.2) 3.40 (86.4) 1.10 (27.9) 3.60 (91.4) 11.30 (287.0) 10.70 (271.8) 10 C2 12.00 (304.8) 19.30 (490.2) 16.90 (429.3) 9.50 (241.3) 16.30 (414.0) 36.00 (914.4) 17.70 (449.6) 3.00 (76.2) 1.50 (38.1) 3.80 (96.5) 18.30 (464.8) 18.00 (457.2) D1 16.80 (426.7) 19.30 (490.2) 16.90 (429.3) 14.60 (370.8) N/A 36.00 (914.4) 17.70 (449.6) 5.10 (129.5) 2.40 (61.0) 5.00 (127.0) 18.30 (464.8) N/A 10 E1 22.30 (566.4) 24.40 (619.8) 16.80 (426.7) 19.50 (495.3) N/A 36.00 (914.4) 22.70 (576.6) 6.50 (165.1) 4.40 (111.8) 5.00 (127.0) 22.40 (569.0) N/A 10 Legend: A= Total depth B= Total width 10 D= Height of removable front cover E= Depth of feet 10 F= Height of middle mounting hole in wall bracket H= Total height 10 L= Width without feet and brackets X= Depth between front and rear mounting holes in inches 10 Y= Width between floor mounting holes Z= Width between wall bracket mounting holes 10 10 10 10 10 10

50 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

AUTOVAR 300 Contents 10 Description Page Product Overview...... 34 10 UNIPUMP ...... 37 UNIPAK...... 40 10 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems 10 Product Selection ...... 52 Options ...... 52 10 Dimensions ...... 53 AUTOVAR 600 Automatic Power Factor Correction 10 Capacitor Systems ...... 54 AUTOVAR Filter—LV Automatic Harmonic Filter ...... 59 10 Transient-Free Static Switching Power Factor Correction Units ...... 63 10 Active-Harmonic Filter-Harmonic Correction Unit— NEMA 1 Enclosure...... 67 10

10

AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems 10 Product Description Features 10 Automatically switched power factor correction Configuration Controller Contactor 10 systems for low voltage ● Cabinet: Wall mounting 12 ● Digital display of power ● Fully rated for capacitor applications. gauge steel with ANSI 61 factor and number of switching up to 60 kVAR gray, NEMA 1 (gasketed) energized banks at 600V 10 ● Wallmount design is ● Power line interconnect: ● Visual indication of ● Integral pre-charge/pre- ideal for minimum space Rugged, power distribution insufficient kVAR to reach insertion module standard. 10 requirements block connection target power factor The contactor reduces ● Programmable to ● Fusing: 200,000 ampere ● LCD backlight display damaging switching 10 automatically add/subtract interrupting capacity ● transients. This provides capacitor banks to maintain Capacitors disabled in provided on all three safety and durability for 10 preset target power factor steps within 35 ms of main phases of each bank. the system: ● power interruption Heavy-duty, three-phase Blade-type fuses mounted ● Lessens the chance capacitor construction ● Harmonic measurement 10 on insulator stand-offs with up to 19 harmonic and of disrupting sensitive ● Five-year warranty of cells blown-fuse indicating lights alarm (THDV) electronic equipment 10 ● Blown-fuse lights: Blown- ● Reduced inrush current Application Description ● Automatic detection and fuse indicating lights for extends the life of the Service entrance power correction of CT and phase 10 each phase and stage polarity capacitor cells factor correction installations located on the door requiring precise ● Automatic detection of ● Additional Features 10 maintenance of target Door interlock: Door connected steps interlock automatically ● Optional molded case power factor in a very ● Maximum 14 output steps circuit breaker rated 10 small footprint. disengages capacitors. Power continues to be ● Provides protection 65 kAIC at 480V and 600V provided to the unit until against overvoltage, ● Personnel ground fault 10 the disconnect is open overtemperature and interruption provides harmonic overload events ● Exhaust fans: Provide protection in case of 10 ventilation. Dust filtering ● Advanced control features accidental contact with included available control power and ground 10 ● Optional communications ● NEMA 3R weatherproofing capability (C option controller) 10 ● Standard metering capability Standards and Certifications ● ● Voltage UL/CSA listed and recognized 10 ● Current (sensed phase only) 10 ● Frequency ● Active power (kW) 10 ● Reactive power (kVAR) ● Apparent power (kVA) 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 51 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 Product Selection

10 Wallmounted Wallmounted Switched Capacitor Banks—Low Voltage Applications Switched Capacitor Step x Rated Current Case Shipping Weight Catalog Bank 10 kVAR kVAR Amperes Size in Lbs (kg) Number 10 240 Volt 25 5 x 5 60 J 217 (98.5) 25MCSR2313 10 50 5 x 10 120 J 255 (115.8) 50MCSR2313 75 5 x 15 180 J 260 (118.0) 75MCSR2313 10 100 5 x 20 240 J 270 (122.6) 100MCSR231 125 5 x 25 300 J 292 (132.6) 125MCSR231 10 150 5 x 30 361 J 314 (142.6) 150MCSR231 10 480 Volt 50 5 x 10 60 J 200 (90.8) 50MCSR4313 10 75 5 x 15 90 J 210 (95.3) 75MCSR4313 100 5 x 20 120 J 210 (95.3) 100MCSR4313 10 125 5 x 25 150 J 240 (109.0) 125MCSR4313 10 150 5 x 30 180 J 240 (109.0) 150MCSR4313 175 5 x 35 210 J 260 (118.0) 175MCSR431 10 200 5 x 40 241 J 270 (122.6) 200MCSR431 225 5 x 45 270 J 290 (131.7) 225MCSR431 10 250 5 x 50 300 J 292 (132.6) 250MCSR431 300 5 x 60 361 J 310 (140.7) 300MCSR431 10 600 Volt 10 50 5 x 10 48 J 200 (90.8) 50MCSR6313 75 5 x 15 72 J 210 (95.3) 75MCSR6313 10 100 5 x 20 96 J 210 (95.3) 100MCSR6313 125 5 x 25 120 J 240 (109.0) 125MCSR6313 10 150 5 x 30 144 J 240 (109.0) 150MCSR6313 175 5 x 35 168 J 260 (118.0) 175MCSR631 10 200 5 x 40 192 J 270 (122.6) 200MCSR631 10 225 5 x 45 216 J 290 (131.7) 225MCSR631 250 5 x 50 240 J 292 (132.6) 250MCSR631 10 300 5 x 60 288 J 310 (140.7) 300MCSD631 10 Options

10 Description Option Code 10 Current transformer—multi-tap, split core current transformer (3000:5A) TX2 Hands-off auto switch—provides manual control to connect or disconnect capacitor stages regardless of controller output H 10 Remote alarm relay—relay for a remote alarm to indicate inability to reach target power factor A Molded case circuit breaker (65 kAIC at 480V) M 10 Weatherproofing (NEMA 3R) W 10 Communicating controller C Notes 10 Other ratings available, please consult factory. For dimensional information, refer to Page 53. 10 A current transformer with a 5 ampere secondary is required to operate an automatic capacitor bank. Rating based on service entrance ampacity. For other ratios, please consult factory. 10 10

52 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Dimensions Approximate Dimensions in Inches (mm) 10

Enclosure J 10 Front View Side View 10 On/Off 0.63 Switch (16.0) 10

Power 10 Factor Controller 10

Keylock Handle 10

A 10

Blown 10 Fuse Lights 10

29.88 10 (759.0) 36.00 10 (914.4) 0.63 (16.0) B 10 10 Enclosure J Description Height A Depth B 10 Without MCCB 36.00 (914.4) 14.00 (355.6) 10 With MCCB 60.00 (1524.0) 14.00 (355.6) 10 10 10 10 10 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 53 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 AUTOVAR 600 Contents Description Page 10 Product Overview ...... 34 UNIPUMP...... 37 10 UNIPAK ...... 40 AUTOVAR 300 Automatic Power Factor Correction 10 Capacitor Systems...... 51 AUTOVAR 600 Automatic Power Factor Correction 10 Capacitor Systems Standards and Certifications ...... 55 10 Product Selection ...... 56 Options ...... 57 10 Dimensions ...... 58 AUTOVAR Filter—LV Automatic Harmonic Filter ...... 59 10 Transient-Free Static Switching Power Factor Correction Units...... 63 10 Active-Harmonic Filter-Harmonic Correction Unit— NEMA 1 Enclosure ...... 67 10

10 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems 10 Product Description Features Programmable to ● Heavy-duty, three-phase ● Fusing: UL recognized, ● Exhaust fans: Two fans 10 automatically add/subtract capacitor construction 200,000 ampere per cabinet provide thermal capacitor banks to maintain ● Five-year warranty of cells interrupting capacity protection. Dust filtering 10 preset target power factor. provided on all three provided Configuration phases of each bank. ● Ease of expansion: Application Description Blade-type fuses mounted 10 ● Cabinet: 12 gauge steel Capacitor stage nests are Service entrance power with ANSI 61 gray, powder on insulator stand-offs self-contained and can be factor correction installations coat finish. Lift bolts ● Blown-fuse lights: Blown- added in the field. Two 10 requiring precise standard, NEMA 1 fuse indicating lights bolts mount the nest in the maintenance of target ● located on the door- field. Control wire plugs power factor. Power line interconnect: 10 Rugged, copper bus bar mounted blown and at connect to factory standard connection with access individual fuses to facilitate wire harness on the left 10 provided for top or bottom tracing of cleared fuses side of the cabinet entry. Bus bars are braced ● Push-to-test: Allows ● Ease of replacement: 10 for 65 kAIC at 480V. All testing of door-mounted Cells can be easily internal power wiring blown fuse indicating lights individually replaced by connections from bus are ● AutoLocate: When door is removing the mounting 10 laid out on a most direct open and bus energized, bolt and lifting out of the basis with minimum fuse circuit automatically nest without removal of 10 bends for ease of checks for cleared fuses. any other components troubleshooting. Clear If a fuse has cleared, the 10 barrier limiting access to light at the fuse comes on live parts included standard for easy troubleshooting 10 ● Modular tray design: ● Door interlock: Door Capacitor banks arranged interlock automatically 10 in modular trays with turns off control circuit capacitors, fuses, blown- when engaged. Power fuse indicating lights, and continues to be provided 10 contactors grouped in a to the unit until disconnect logical, easily understood is open 10 layout. This permits easy access, quick identification 10 of operating problems and ease of expandability 10 10 10

54 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Controller Contactor ● Digital display of power ● Fully rated for capacitor 10 factor and number of switching up to 60 kVAR energized banks at 600V 10 ● Visual indication of ● Integral pre-charge/pre- insufficient kVAR to reach insertion module standard. 10 target power factor The contactor reduces ● LCD backlight display damaging switching 10 transients. This provides ● Capacitors disabled in steps within 35 ms of main safety and durability for 10 power interruption the system: ● Lessens the chance of ● Harmonic measurement 10 up to 19 harmonic and disrupting sensitive alarm (THDV) electronic equipment ● Reduced inrush current 10 ● Automatic detection and correction of CT and phase extends the life of the capacitor cells polarity Modular Step Nest Assembly 10 ● Automatic detection of Additional Features 10 connected steps ● Optional molded case AUTOVAR 600—Interior View ● Maximum 14 output steps circuit breaker, rated 65 10 ● Provides protection kAIC at 48V and 600V against overvoltage, ● Personnel ground fault 10 overtemperature and interruption provides harmonic overload events protection in case of ● Advanced control features accidental contact with 10 available control power and ground ● Optional communications ● Control wiring—standard 10 capability (C option controller) NEC color-coded modular ● Standard metering capability bundles with quick 10 ● Voltage disconnect feature for ease of troubleshooting or ease ● Current (sensed phase 10 of expendability only) ● Optional digital metering ● Frequency 10 ● Active power (kW) ● Reactive power (kVAR) 10 ● Apparent power (kVA) Bottom Entry Location 10 Factory Pre-Wired for Future Expansion 10 10 Standards and Certifications ● UL/CSA listed 10 and recognized 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 55 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 Product Selection Floor-Mounted Switched Capacitor Banks—Low Voltage Applications 10

10 Floor-Mounted 240 Vac Switched Capacitor Step x Rated Current Enclosure Shipping Weight Catalog Bank 10 kVAR kVAR Amperes Size in Lbs (kg) Number 75 3 x 25 180 L 644 (292.4) 75TPCSR231 10 100 4 x 25 214 L 692 (314.2) 100TPCSR231 10 125 5 x 25 300 L 740 (336.0) 125TPCSR231 150 6 x 25 316 L 788 (357.8) 150TPCSR231 10 200 8 x 25 481 L 884 (401.3) 200TPCSR231 250 10 x 25 600 L 944 (428.6) 250TPCSR231 10 300 12 x 25 720 L 1022 (464.0) 300TPCSR231 350 7 x 50 844 KK 1616 (734.0) 350TPCSR231 10 400 8 x 50 965 KK 1704 (774.0) 400TPCSR231 10 10 480 Vac Step x Rated Current Enclosure Shipping Weight Catalog 10 kVAR kVAR Amperes Size in Lbs (kg) Number 150 3 x 50 180 L 632 (287.0) 150TPCSR431 10 200 4 x 50 240 L 676 (306.9) 200TPCSR431 250 5 x 50 300 L 720 (326.9) 250TPCSR431 10 300 6 x 50 360 L 764 (346.9) 300TPCSR431 350 7 x 50 420 L 808 (366.8) 350TPCSR431 10 400 8 x 50 480 L 852 (386.8) 400TPCSR431 10 450 9 x 50 540 L 896 (406.8) 450TPCSR431 500 10 x 50 600 L 944 (428.6) 500TPCSR431 10 550 11 x 50 660 L 984 (446.7) 550TPCSR431 600 12 x 50 720 L 1022 (464.0) 600TPCSR431 10 660 11 x 60 792 L 1010 (458.5) 660TPCSR431 700 7 x 100 840 L 1616 (734.0) 700TPCSR431 10 720 12 x 60 864 L 1050 (476.7) 720TPCSR431 10 800 8 x 100 960 KK 1704 (774.0) 800TPCSR431 840 14 x 60 1008 L 1690 (767.7) 840TPCSR431 10 900 9 x 100 1080 KK 1792 (814.0) 900TPCSR431 1000 10 x 100 1200 KK 1888 (857.0) 1000TPCSR431 10 1100 11 x 100 1320 KK 1966 (893.0) 1100TPCSR431 10 1200 12 x 100 1440 KK 2044 (928.0) 1200TPCSR431 Notes 10 Other ratings and step configurations available, please consult factory. For dimensional information, refer to Page 58. 10 10 10 10 10 10

56 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Floor-Mounted 600 Vac Capacitor Bank Step x Rated Current Enclosure Shipping Weight Catalog 10 kVAR kVAR Amperes Size in Lbs (kg) Number 150 3 x 50 144 L 632 (287.0) 150TPCSR631 10 200 4 x 50 192 L 676 (306.9) 200TPCSR631 10 250 5 x 50 240 L 720 (326.9) 250TPCSR631 300 6 x 50 288 L 764 (346.9) 300TPCSR631 10 350 7 x 50 336 L 808 (366.8) 350TPCSR631 400 8 x 50 384 L 852 (386.8) 400TPCSR631 10 450 9 x 50 432 L 896 (406.8) 450TPCSR631 10 500 10 x 50 480 L 944 (428.6) 500TPCSR631 550 11 x 60 528 L 984 (446.7) 550TPCSR631 10 600 12 x 50 576 L 1022 (464.0) 600TPCSR631 660 11 x 60 634 L 1010 (458.5) 660TPCSR631 10 700 7 x 100 672 L 1616 (734.0) 700TPCSR631 720 12 x 60 692 L 1050 (476.7) 720TPCSR631 10 800 8 x 100 768 KK 1704 (774.0) 800TPCSR631 10 840 14 x 60 1008 L 1690 (767.7) 840TPCSR631 900 9 x 100 864 KK 1792 (814.0) 900TPCSR631 10 1000 10 x 100 960 KK 1888 (857.0) 1000TPCSR631 1100 11 x 100 1056 KK 1966 (893.0) 1100TPCSR631 10 1200 12 x 100 1152 KK 2044 (928.0) 1200TPCSR631 10

Options 10

Description Option Code 10 Current transformer—multi-tap, split core current transformer (3000:5A) TX2 10 Hands-off auto switch—provides manual control to connect or disconnect capacitor stages regardless of controller output H Remote alarm relay—relay for a remote alarm to indicate inability to reach target power factor A 10 Molded case circuit breaker (65 kAIC at 480V) M Weatherproofing (NEMA 3R) W 10 Communicating controller C IQ 250 solid-state meter Q 10

Notes 10 Other ratings and step sizes available, please consult factory. A current transformer with a 5 ampere secondary is required to operate an automatic capacitor bank. Rating based on service entrance ampacity. 10 For other ratios, please consult factory. Not available with weatherproofing option. 10 For dimensional information, refer to Page 58. 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 57 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

Dimensions 10 Approximate Dimensions in Inches (mm) 10 Enclosure L Front View

10 (Note: Fans are 38.50 (Note: Fans are 26.25 Vertical Toward (977.9) (666.8) Back of Enclosure) Side by Side) 10 Fans Fans 10 1 Ground Lug 10 2

DANGER HIGH VOLTAGE CAUTION PHASE A PHASE B PHASE C 10 DISCONNECT BEFORE SERVICING

3 71.25 10 11.75 (1809.8) 75.00 (298.5) (1905.0) 10 46.00 10 (1168.4) 10 10 3.00 10 (76.2)

6.00 10 Filter Tray (152.4) Legend 13.00 1. Controller (330.2) 0.438 ø Mounting Holes 10 2. On/Off Switch 25.00 2 per Channel 3. Blown Fuse Indicator Lights (635.0) 10 Enclosure KK Front and Side Views 10 Fans 78.25 Fans 26.25 10 (1987.6) (666.8) (Note: Fans are (Note: Fans are 10 Vertical Towards Side by Side) 1 Back of Enclosure) Ground Lug 10 2

10 PHASE A PHASE B PHASE C

BEFORE SERVICING 3 71.25 (1809.8) 10 11.75 75.00 (298.5) (1905.0) 10 46.00 10 (1168.4) 10

10 3.00 0.438 ø (76.2) Mounting Holes 10 2 per Channel

13.00 10 Legend Filter Tray Filter Tray (330.2) 1. Controller 6.00 (152.4) 2. On/Off Switch 25.00 10 3. Blown Fuse Indicating Light (635.0) 10

58 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

AUTOVAR Filter Contents 10 Description Page Product Overview...... 34 10 UNIPUMP ...... 37 UNIPAK...... 40 10 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems ...... 51 10 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems ...... 54 10 AUTOVAR Filter—LV Automatic Harmonic Filter Standards and Certifications ...... 60 10 Product Selection ...... 61 Options ...... 61 10 Dimensions ...... 62 Transient-Free Static Switching Power Factor 10 Correction Units ...... 63 Active-Harmonic Filter-Harmonic Correction Unit—NEMA 1 10 Enclosure ...... 67 10

AUTOVAR Filter—LV Automatic Harmonic Filter 10 Product Description Features 10 Automatically switched ● Efficient modular design ● Power line interconnect: ● Push-to-test: Allows harmonic filter/ power for short lead-times, ease Rugged, copper bus bar testing of door-mounted 10 factor corrections systems. of maintenance and ease connection with access blown fuse indicating lights. of future expansion provided for top or bottom ● AutoLocate: When door is ● Programmable to 10 ● entry. Bus bars are braced automatically add/subtract Heavy-duty, three-phase open and bus energized, capacitor construction with for 65 kAIC at 480V. All fuse circuit automatically filter banks to maintain internal power wiring 10 preset target power factor reliable, threaded terminal checks for cleared fuses. connections connections from bus are If a fuse has cleared, the ● Filter steps tuned for ● laid out on a most direct light at the fuse comes on 10 maximum efficiency in Cool operating, 100% copper wound, thermal basis with minimum bends for easy troubleshooting reducing harmonic for ease of troubleshooting. ● 10 currents in three-phase protected reactors are Door interlock: Door sized up to 150% of rated Clear barrier limiting interlock automatically environments with heavy access to live parts nonlinear loads capacitor current turns off control circuit 10 included standard when engaged. Power Application Description Configuration ● Modular tray design: continues to be provided Capacitor banks arranged 10 Service entrance power ● Operation: AUTOVAR to the unit until disconnect harmonic filters are in modular trays with is open factor correction installations capacitors, fuses, blown- 10 requiring precise maintenance designed to be sized the ● Exhaust fans: Two same as any power factor fuse indicating lights, and fans per cabinet provide of target power factor in contactors grouped in a three-phase, nonlinear, high correction unit. In most low thermal protection. 10 voltage applications where logical, easily understood Dust filtering provided harmonic environments. layout. This permits easy harmonics are generated ● 10 access, quick identification Ease of expansion: by nonlinear loads, Capacitor stage nests are no harmonic audit is of operating problems and ease of expandability self-contained and can be 10 necessary to design the added in the field. Control ● AUTOVAR filter because Fusing: UL recognized, wire plugs connect to 10 it is already designed 200,000 ampere factory standard wire for typical harmonic interrupting capacity harness on the left side spectrums at the kVAR provided on all three of the cabinet 10 phases of each bank. size specified ● Blade-type fuses mounted Ease of replacement: ● Cabinet: 12 gauge steel 10 on insulator stand-offs Cells can be easily with ANSI 61 gray, powder individually replaced by ● coat finish. Lift bolts Blown-fuse lights: Blown- removing the mounting 10 standard, NEMA 1 fuse indicating lights bolt and lifting out of the located on the door- nest without removal of 10 mounted blown and at any other components individual fuses to facilitate tracing of cleared fuses 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 59 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

Controller Reactors Additional Features Standards and Certifications 10 ● Digital display of power ● Tuning: Reactors tuned ● Optional molded case ● UL/CSA listed factor and number of to the 4.7th harmonic circuit breaker rated and recognized 10 energized banks order (nominal 5th). 65 kAIC at 480V and 600V ● Visual indication of This provides maximum ● Personnel ground fault 10 insufficient kVAR to reach effectiveness in reducing interruption provides target power factor harmonic currents in protection in case of three-phase systems ● LCD backlight display accidental contact with 10 with harmonics caused ● control power and ground Capacitors disabled in by six-pulse devices steps within 35 ms of main ● Control wiring—standard 10 ● power interruption Detuning: Reactor NEC color-coded modular designs can be detuned bundles with quick ● Harmonic measurement 10 upon request to 4.2nd to disconnect feature for up to 19 harmonic and protect capacitors against alarm (THDV) ease of troubleshooting 10 alternate harmonics or ease of expendability ● Automatic detection and ● Windings: 100% copper 10 correction of CT and phase windings for minimal polarity temperature rise under 10 ● Automatic detection of load connected steps ● Thermal overload 10 ● Maximum 14 output steps protection: Each reactor ● Provides protection includes three normally against overvoltage, closed, auto reset 10 overtemperature and thermostats that harmonic overload events open at 180°C. When 10 ● Advanced control features thermostats engage, available the contactor opens ● 10 ● Optional communications Insulation: 220°C capability (C option controller) insulation system ● 10 ● Standard metering capability Warranty: One-year replacement of reactors ● Voltage 10 ● Current (sensed phase only) 10 ● Frequency ● Active power (kW) 10 ● Reactive power (kVAR)

● AUTOVAR Filter—Reactor Cabinet 10 Apparent power (kVA) Contactor 10 ● Fully rated for capacitor switching up to 60 kVAR 10 at 600V ● Integral pre-charge/pre- 10 insertion module standard. The contactor reduces 10 damaging switching transients. This provides safety and durability for 10 the system: ● Lessens the chance of 10 disrupting sensitive electronic equipment 10 ● Reduced inrush current extends the life of the 10 capacitor cells 10 10 10 10

60 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Product Selection 10 Low Voltage Switched Harmonic Filters 10

Floor-Mounted Floor-Mounted Switched Harmonic Filters—Low Voltage 10 Switched Harmonic Step x Rated Current Enclosure Shipping Weight Catalog Filter kVAR kVAR Amperes Size in Lbs (kg) Number 10 480 Vac 200 4 x 50 240 L 1438 (652.9) 200THFSR431 10 250 5 x 50 300 L 1634 (741.8) 250THFSR431 10 300 6 x 50 360 KK or L + L 1830 (830.8) 300THFSR432 350 7 x 50 420 KK or L + L 2026 (919.8) 350THFSR432 10 400 8 x 50 480 KK or L + L 2222 (1008.8) 400THFSR432 450 9 x 50 540 KK or L + L 2371 (1076.4) 450THFSR432 10 500 10 x 50 600 KK or L + L 2525 (1146.4) 500THFSR432 550 11 x 50 660 KK or L + L 2750 (1248.5) 550THFSR432 10 600 12 x 50 720 KK or L + L 2830 (1284.8) 600THFSR432 10 600 Vac 300 6 x 50 288 KK or L + L 1830 (830.8) 300THFSR632 10 350 7 x 50 336 KK or L + L 2026 (919.8) 350THFSR632 400 8 x 50 384 KK or L + L 2222 (1008.8) 400THFSR632 10 450 9 x 50 432 KK or L + L 2371 (1076.4) 450THFSR632 500 10 x 50 480 KK or L + L 2525 (1146.4) 500THFSR632 10 550 11 x 50 528 KK or L + L 2750 (1248.5) 550THFSR632 10 600 12 x 50 576 KK or L + L 2830 (1284.8) 600THFSR632 10 Options 10 Description Option Code 10 Current transformer—multi-tap, split core current transformer TX2 Hands-off auto switch—provides manual control to connect or disconnect capacitor stages regardless of controller output H 10 Remote alarm relay—relay for a remote alarm to indicate inability to reach target power factor A Molded case circuit breaker (65 kAIC at 480V) M 10 Weatherproofing (NEMA 3R) W 10 Communicating controller C IQ 250 solid-state meter Q 10 Notes 10 Enclosures for 550 and 600 kVAR at 480 and 600V will be one double-door section wide if circuit breakers are required (enclosure size KK). Enclosure for 250 kVAR at 480V will be one double-door section wide if a circuit breaker is required. Other ratings available, please consult factory. 10 L + L under enclosure size denotes two size L enclosures—one for the capacitors, one for the reactor case. For KK enclosure design, change the last digit of the catalog number to 1. For example, 500THFSR431. 10 A current transformer with a 5 ampere secondary is required to operate an automatic capacitor bank. Rating based on service entrance ampacity. For other ratios, please consult factory. Not available with weatherproofing option. 10 For dimensional information, refer to Page 62. 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 61 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

Dimensions 10 Approximate Dimensions in Inches (mm) 10 Enclosures L + L Front and Side Views 10 (Note: Fans are 89.00 26.25 Vertical Toward (2260.6) (Note: Fans are (666.8) 10 Back of Enclosure) 38.50 38.50 Side by Side) (977.9) (977.9) 10 Fans Fans (Note: Fans are (Note: Fans are Ground 10 Side by Side) Vertical Towards Lug 1 Back of Enclosure) Fans 10 2 Fans DANGER DANGER

10 PHASE A PHASE B PHASE C 71.25 75.00 (1809.8) (1905.0) 3 10 11.75 (298.5) 10 46.00 10 (1168.4)

10 12.00 3.00 10 (76.2)

6.00 10 (152.4) Legend 13.00 1. Controller Power Wire 0.438 ø Filter Tray (330.2) 10 2. On/Off Switch Interconnect Filter Tray Mounting Holes 3. Phase A, B and C Blown Conduit 25.00 2 per Channel 10 Fuse Indicating Lights (635.0) 10 10 10 10 10 10 10 10 10 10 10 10 10 10

62 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Transient-Free Power Factor Correction System Contents 10 Description Page Product Overview...... 34 10 UNIPUMP ...... 37 UNIPAK...... 40 10 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems ...... 51 10 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems ...... 54 10 AUTOVAR Filter—LV Automatic Harmonic Filter ...... 59 Transient-Free Static Switching Power Factor Correction Units ...... 10 Features, Benefits and Functions ...... 64 Standards and Certifications ...... 64 10 Catalog Number Selection ...... 65 Technical Data and Specifications ...... 65 10 Dimensions ...... 66 Active-Harmonic Filter-Harmonic Correction Unit— 10 NEMA 1 Enclosure...... 67 10

Transient-Free Static Switching Power Factor Correction Units 10 Product Description Application Description 10 Transient-free statically The FTA and FTE units ● Motor starting Rating based on Service switch capacitor units are employ a fast or real-time ● On-site generation support Entrance Ampacity. For other 10 available in two models. response, and include the ratios, please consult factory. ● Spot welding ability to switch larger steps ● ● The FTE model is a real-time without creating significant Wind turbines Startup and 10 transient-free system, used line noise. These relatively ● Other dynamic loads Commissioning by to compensate extremely maintenance-free units reside factory trained personnel 10 Three current transformers rapid loads within one in a smaller footprint and are is required for proper with a 5 ampere secondary cycle of operation (typically ideal for use in applications operation and warranty are required to operate this 10 5–20 msec). such as flicker control, large of this system capacitor bank. The FTA model is a fast motor starting, bus voltage 10 transient-free system, used stabilization, fault ride to compensate any loads through solutions, power 10 within 3–4 seconds. factor correction and many more. 10 10 10 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 63 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 Application Example—Spot Welding Spot Welding (Auto Manufacturer) 10 230 10 10 220

210 10 Without With 1800 10 10 1400

10 1000 10 300 150

10 L1-Q (kVAR) L1-Current (A) (V) L1-Voltage 0 10 21:33:38 :40 :42 :44 :46 :48 :50 :52 :54 :56 :58 :00 :02 :04 :06 :08 10 10 Features, Benefits and Functions 10 ● Transient-free capacitor ● Unique SCAN feature FTE unit includes all of the group switching, using reduces capacitor above, plus: electronic switching duty cycles ● Reduces voltage flicker 10 elements ● Remote control of and voltage sag ● Simultaneous connection/ compensation systems ● 10 disconnection of all available via LAN Provides network reactive required steps or Ethernet power support ● 10 ● Consistent capacitor ● Integrated three-phase Offers voltage control values and stable filter network analyzer: options 10 characteristics ● Measures all power ● Harmonic filtration parameters on each 10 ● Three independent phase (V, I, kW, control modes: kVAR, kVA) 10 ● Power factor control ● Measures voltage and current harmonics to ● Voltage control the 63rd harmonic 10 ● Load sharing with another compensation 10 system connected to the same transformer 10 10 Standards and Certifications 10 Enclosure ● EMC—EN50081-2, ● Safety—EN61010-1, 10 EN50082-2, EN55011, EN60439-1, EN60204 EN61000-4-2/3/4/5, ● UL 508 ENV50204, ENV50141 ● CSA 10 ● CE Mark—73/23/EEC am. 93/68, 98/37/EC art. 4(2) 10 10 10

64 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Catalog Number Selection 10 TFSS 10 FTA 100 6 2 480 P14 N12 - M3 - COM 10 10 Model Optional FTE = Real-time balanced Number of Groups Percent Reactory (Tuning) Enclosure COM = Communications Card 10 FTEUN = Real-time unbalanced Maximum 12 P14 = 14% (2.67th order) N1 = NEMA 1 RS-485/Modbus FTA = Fast acting P7 = 7% (3.8th order) N12 = NEMA 12 10 FTES = Motor starting systems P567 = 5.67% (4.2nd order) N3R = NEMA 3R Switching Sequence Optional FTER = Grid fault ride-through systems P49 = 4.9% (4.5th order) 1 = 1:1:1:1 Measurement Levels 10 2 = 1:2:2:2 M2 Total Power in kVAR 3 = 1:2:4:4 System Voltage M3 Typical in steps of 50 kVAR 480 = 480V M4 10 beginning with 100 kVAR 600 = 600V 690V or above = MV 10 10 Technical Data and Specifications

Product Configurations 10 Network voltage Capacitor group Acquisition time configurations 10 ● 210–690V ● FTE—5–20 ms for a ● Engineered solutions ● Up to 12 groups per 50 Hz network 10 up to 15 kV one controller ● FTE—4–16 ms for a ● Switching sequence: 60 Hz network Frequency 10 ● 1:1:1:1 (all equal) ● FTA—1–4 second ● 45–55 Hz for 50 Hz ● 1:2:2:2 (half group) maximum 10 network ● 1:2:4:4 (quarter, half ● 55–65 Hz for 60 Hz groups) 10 network 10 Notes All models are CE approved. Please notify if UL or cUL is required. 10 MV units require: A correctly sized and specified step-up transformer MV and LV interconnection, switching and protection 10 All systems are offered with Measurement Level 1 (f, I, V, kW, kVAR, kVA, PF) and no communications card. The measurement levels can be upgraded to Measurement Level 2 (adds THD I and THDV), Measurement Level 3 (adds waveforms, I and V harmonics) and Measurement Level 4 (adds event log). 10 Balanced system employs two-phase switching, unbalanced system employs individual three-phase switching. For motor start and grid fault ride-through solutions, please consult factory. 10 10 10 10 10 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 65 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

Dimensions 10 Approximate Dimensions in Inches (mm)

10 Transient-Free Reactive Power Compensation Systems— Transient-Free Reactive Power Compensation Systems— Real-Time Transient-Free Systems—480 Vac Fast Transient-Free Switching Systems—480 Vac 10 Compensate Rapid Loads Within One Cycle (Typically 5–20 ms)—Standard 6% Inductors— Compensate Any Load Within 3–4 Seconds—Standard 6% 10 Detuned to 245 Hz (4.08th Harmonic) Inductors—Detuned to 245 Hz (4.08th Harmonic) Catalog Catalog 10 Number Width Depth Height Number Width Depth Height 10 FTE15652480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA15652480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE18752480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA18752480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 10 FTE21974480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA21974480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE25052480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA25052480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 10 FTE26274480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA26274480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 10 FTE31252480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA31252480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE37552480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA37552480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 10 FTE43774480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA43774480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE45031480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA45031480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 10 FTE60661480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA60661480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTE687112480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA687112480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) 10 FTE75061480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA75061480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) 10 FTE825112480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA825112480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTE90061480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA90061480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) 10 FTE112591480 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTA112591480 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTE135091480 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTA135091480 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) 10 FTE1500121480 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) FTA1500121480 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) 10 FTE1800121480 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) FTA1800121480 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) Compensate Rapid Loads Within One Cycle 10 (Typically 5–20 ms)—4.5% Inductors— Compensate Any Load Within 3–4 Seconds—4.5% Tuned to 282 Hz (4.7th Harmonic) Inductors—Tuned to 282 Hz (4.7th Harmonic) 10 Catalog Catalog Number Width Depth Height Number Width Depth Height 10 FTE15652480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA15652480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 10 FTE18752480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA18752480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE21974480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA21974480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 10 FTE25052480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA25052480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE26274480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA26274480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 10 FTE31252480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA31252480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE37552480T 31.50 (800.1) 23.60 (599.4) 82.07 (2100.6) FTA37552480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 10 FTE43774480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA43774480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 10 FTE45031480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA45031480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE60661480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA60661480T 63.00 (1600.2) 23.60 (599.4) 82.07 (2100.6) 10 FTE687112480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA687112480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTE75061480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA75061480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) 10 FTE825112480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA825112480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTE90061480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA90061480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) 10 FTE112591480T 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTA112591480T 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) 10 FTE135091480T 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTA135091480T 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTE1500121480T 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) FTA1500121480T 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) 10 FTE1800121480T 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) FTA1800121480T 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) 10

66 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Harmonic Correction Units—NEMA 1 Enclosure Contents 10 Description Page Product Overview...... 34 10 UNIPUMP ...... 37 UNIPAK...... 40 10 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems ...... 51 10 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems ...... 54 10 AUTOVAR Filter—LV Automatic Harmonic Filter ...... 59 Transient-Free Static Switching Power Factor 10 Correction Units ...... 63 Active-Harmonic Filter-Harmonic Correction Unit— 10 NEMA 1 Enclosure Technical Data and Specifications ...... 68 10 Wiring Diagrams ...... 68 Dimensions ...... 70 10

10

Active-Harmonic Filter-Harmonic Correction Unit—NEMA 1 Enclosure 10 Product Description Features, Benefits Standards and Certifications 10 Active Harmonic Filters and Functions ● UL/CSA approved (Harmonic Correction Units— Unlike passive filters, by Advantages 10 HCUEs) provide dynamic providing dynamic correction, ● Can be sized to guarantee harmonic correction by HCUEs can provide effective specific levels of harmonic 10 actively injecting equal and harmonic correction for correction, such as opposite currents into the varying load conditions and meeting IEEE 519 customer’s electrical harmonic spectrums up to recommended levels 10 distribution system that their rated capacity. HCUEs ● Cannot be overloaded cancel the entire spectrum also have the secondary ● Can be expanded without 10 of harmonic currents at the benefit of providing power affecting performance point of connection. factor correction with any ● Broad spectrum of 10 excess capacity after cancellation (2nd to Application Description correcting all harmonic 50th harmonic) 10 Typical applications include conditions. locations with large amounts ● Power factor improvement ● of nonlinear loads including Fast action ● Easier and less expensive 10 6- and 12-pulse PWM AC ● NEMA 1 and NEMA 12 installation variable frequency drives, enclosures available: ● Comprehensive control 10 DC drives, as well as other ● Wallmount (50 and switch-mode power supply 100 ampere designs) 10 equipment. This equipment ● Floor-standing can be found in water and (300 ampere design) wastewater treatment 10 facilities, industrial ● Touchscreen HMI manufacturing and ● Modbus and Ethernet 10 warehousing plants, military connectivity bases, and commercial Note: Requires at least 3% 10 (HVAC) locations. series input line reactor or equivalent 6% DC bus choke 10 in each AC drive for optimum performance. 10 10 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 67 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

Technical Data and Specifications 10 ● 20 kHz switching carrier frequency 10 ● 208–480V ±10%, 600V and 690V with autotransformer ● 50/60 Hz +/–3 Hz frequency 10 ● Ambient temperature 0°C to +40°C enclosed ● Seismic Zone 4 10 ● Output capacity—self limited to 100% current rated ● Corrective capability—<5% TDD and near unity 10 displacement power factor 10 Harmonic Control Unit Ratings—NEMA 1 Enclosed Total Current Watt Losses 10 Model Voltage Frequency Amperes (rms) (kw) Enclosure Type Disconnect HCUE050D5N1 208–480 50/60 Hz 50 1.8 Wallmount/NEMA 1 — 10 HCUE100D5N1 208–480 50/60 Hz 100 3.0 Wallmount/NEMA 1 — HCUE300D5N1 208–480 50/60 Hz 300 8.0 Free-standing/NEMA 1 X 10 HCUE050D6N1 600 50/60 Hz 39 1.8 Free-standing/NEMA 1 — 10 HCUE050D7N1 690 50/60 Hz 33 1.8 Free-standing/NEMA 1 — HCUE100D6N1 600 50/60 Hz 78 3.0 Free-standing/NEMA 1 — 10 HCUE100D7N1 690 50/60 Hz 65 3.0 Free-standing/NEMA 1 — HCUE300D6N1 600 50/60 Hz 235 8.0 Free-standing/NEMA 1 — 10 HCUE300D7N1 690 50/60 Hz 200 8.0 Free-standing/NEMA 1 — 10 Current Transformer Ratings 10 AC Line Model Current Rating Type 10 HCUCT1000SC 1000 Split 10 HCUCT3000SC 3000 Split HCUCT5000SC 5000 Split 10 10 Wiring Diagrams Installation Diagram 10 Load(s) 10 Source Typical CT 10 Transformer Placement 10 10 Alternate CT 10 Placement HCU

10 Note Current transformers are rated for 400 Hz. Two current transformers are required for three- 10 phase loads. Three current transformers are required when single-phase loads are present. Rating based on service entrance ampacity and optional parallel operation. For other ratios, please consult factory. 10 Startup and commissioning by factory trained personnel is required for proper operation and warranty of this system. 10 10 10

68 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Source CT Location Source or Load CT Location 10 Utility Transformer Utility Transformer or or Upstream Panel Upstream Panel 10

Distribution Panel or Distribution Panel or 10 Motor Control Center Motor Control Center 10 10 10 10 Corrected Corrected Corrected Other Other Load Load Load Loads Loads 10 10

Less than 10 25 Feet per NEC 240-21 10 Harmonic Cancellation and/or Power-Factor Correction of all Loads 10 HCU Three Possible on Panel HCU CT Locations Corrected Shown 10 Load 10

Source or Load CT Location Load CT Location 10

Utility Transformer Utility Transformer 10 or Upstream Panel or Upstream Panel 10 Distribution Panel or Motor Control Center Distribution Panel or Motor Control Center 10 10 10

More than 10 25 Feet per Other Loads Other Loads NEC 240-21 10 Other Corrected Other Loads Load Loads 10 Junction Box NEED IMAGE! Four Possible 10 Breaker CT Locations or Fused Shown Disconnect 10 – Harmonic Cancellation 10 and/or Power-Factor Correction of a Selected HCU HCU Load on Panel 10 Corrected Load 10 10 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 69 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

Dimensions 10 Approximate Dimensions in Inches (mm)

10 Harmonic Control—NEMA 1 Enclosed Current Transformer Exterior Model Internal Diameter 10 Unit Weight Model Height Weight Depth in Lbs (kg) HCUCT1000SC 4.65 (118.1) 10 HCUE050D5N1 51.80 (1315.7) 20.70 (525.8) 18.50 (469.9) 250 (113.5) HCUCT3000SC 6.50 (165.1) HCUE100D5N1 68.70 (1745.0) 20.70 (525.8) 18.50 (469.9) 350 (158.9) HCUCT5000SC 7.50 (190.5) 10 HCUE300D5N1 74.90 (1902.5) 32.20 (817.9) 19.50 (495.3) 775 (351.9) Auxiliary Current Transformers 10 HCUE050D6N1 HCUE050D7N1 Model Ratio Type 10 HCUE100D6N1 HCUCT7RL6011 600/1 Solid round core HCUE100D7N1 HCUCT7RL1021 1000/1 Solid round core 10 HCUE300D6N1 Notes HCUE300D7N1 Consult factory. 10 Required for parallel operation of HCU and for units with transformers. Use the same number of auxiliary CTs as main sensing CTs. 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

70 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Approximate Dimensions in Inches (mm) 10 Drawings—NEMA 1 Enclosure HCUE050 Layout Dimensions 10 The HCUE050 series offers 50 amperes of corrective current in a convenient package. The enclosed model comes standard 10 with a digital interface panel for control diagnostics and programming. Input fuses are included. The enclosed unit includes a removable panel for bottom conduit entry. 10 10 HCUE050—50 Amperes, 208–480V

20.70 10 (525.8) 9.80 10 (248.9) Heat Sink Opening

4.60 10 (116.8) 10 10 10

18.70 16.70 (475.0) 10 (424.2) 10 10

17.30 (439.4) 10

5.10 10 (129.5) 4.00 10 (101.6) HMI 50.30 51.80 10 (1277.6) (1315.7) 5.90 (149.9) 10 10 10 10 10

5.30 10 (134.6) 10 Conduit Plate 6.30 (160.0) 10

5.70 10 (144.8) 6.30 (160.0) 10 Inlet Air Opening 8.90 10 (226.1) 5.30 (134.6) 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 71 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 Approximate Dimensions in Inches (mm) HCUE100 Layout Dimensions The HCUE100 series offers 100 amperes of corrective current in 10 a wallmounted NEMA 1 enclosure. The enclosed model comes standard with a digital interface module for control, diagnostics 10 and programming. Input fuses are included. The enclosed unit includes a removable panel for bottom conduit entry. 10 10 HCUE100—100 Amperes 208–480V 20.70 10 (525.8) 9.80 Heat Sink Opening 10 (249.0) 10

10 4.60 (116.8) 10 10 16.70 18.70 (475.0) 10 (424.2) 10

10 20.60 (523.2)

10 5.10 (129.5) 10

HMI 10 4.00 (101.6) 67.20 68.70 10 (1706.9) (1745.0)

5.90 10 (149.9) 10 10 10 10 10 5.30 10 (134.6) 10 Conduit Plate 6.30 (160.0)

10 5.70 6.30 (144.8) 10 (160.0) Inlet Air Opening 8.90 10 (226.1) 5.30 10 (134.6)

72 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters 10.4 Power Factor Correction Capacitors

Approximate Dimensions in Inches (mm) 10 HCUE300 Layout Dimensions The HCUE300 series offers 300 amperes of corrective current for large capacity applications. It is available in a floor-standing 10 NEMA 1 enclosure (including a door-interlocking disconnect). The enclosed model comes standard with digital interface module 10 for control, diagnostics and programming. Input fuses are included. The enclosed unit includes a removable panel for 10 top conduit entry. 10 HCUE300—300 Amperes 208–480V 10 32.00 (812.8) 10 23.20 (589.3) 3.10 (78.7) 10 Conduit Plate 10 6.50 (165.1) Heat Sink Opening 10 10 8.00 (203.2) 21.80 10 (553.7) 28.90 17.10 10 (734.1) (434.3) 10

14.80 10 (375.9)

HMI 10

5.10 10 4.00 (129.5) (101.6) 10

7.40 74.80 77.10 10 (188.0) (1899.9) (1958.3) 10 10.80 (274.3) 10

12.50 10 (317.5) Inlet 10 Air Opening 10 10 0.60 24.30 4X (15.2) (617.2) 0.40 4X 10 (10.2) ”A“ 10

14.70 10 (373.4) Detail ”A“ 10 Scale 1:12 10

Distribution Products Catalog CA08101001E—July 2010 www.eaton.com 73 10.4 SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction Capacitors

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

74 Distribution Products Catalog CA08101001E—July 2010 www.eaton.com