SPD, Power Conditioning, PF and Harmonic Filters

Industrial Surge Protection Products 2.1 Surge Protection and Power Conditioning 2 Introduction ...... V3-T2-2 Product Overview ...... V3-T2-5 2 SPD Series for Integration into Electrical Distribution Equipment . . . . V3-T2-7 SPD Series for Mounting External to Electrical Distribution Equipment V3-T2-11 2 SPV Surge Protective Device ...... V3-T2-16 2 CVX050/100 ...... V3-T2-18 SP1 Surge Protective Device ...... V3-T2-21 2 SP2 Surge Protective Device ...... V3-T2-23 AEGIS Powerline Filters ...... V3-T2-25 2 Sag Ride-Through (SRT) ...... V3-T2-30 2 Electronic Regulator (EVR)...... V3-T2-36 2 2.2 Correction and Harmonic Filtering Product Overview ...... V3-T2-38 2 UNIPUMP ...... V3-T2-41 UNIPAK...... V3-T2-44 2 AUTOVAR 300 Automatic Power Factor Correction Systems V3-T2-55 2 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems V3-T2-58 AUTOVAR Filter—LV Automatic Harmonic Filter...... V3-T2-63 2 Transient-Free Static Switching Power Factor Correction Units ...... V3-T2-67 Active-Harmonic Filter-Harmonic Correction Unit—NEMA 1 Enclosure V3-T2-71 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-1 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Industrial and Commercial Surge Protection Contents Description Page 2 Introduction Product Overview ...... V3-T2-5 2 SPD Series for Integration into Electrical Distribution Equipment ...... V3-T2-7 2 SPD Series for Mounting External to Electrical Distribution Equipment...... V3-T2-11 SPV Surge Protective Device ...... V3-T2-16 2 CVX050/100 ...... V3-T2-18 SP1 Surge Protective Device ...... V3-T2-21 2 SP2 Surge Protective Device ...... V3-T2-23 AEGIS Powerline Filters ...... V3-T2-25 2 Sag Ride-Through (SRT) ...... V3-T2-30 Electronic (EVR)...... V3-T2-36 2 2 2 2 Introduction 2 Industrial and Commercial Surge Protection Critical Load Protection Commercial and Light ● SPD Series for Integration SPD Series Sidemount Units Series filtering and surge Industrial Surge Protection 2 into Electrical Distribution Specification grade surge protection for critical single- Eaton’s SPV series is a Equipment protective devices for phase loads. commercial grade and light ● SPD Series for Mounting installation external to industrial surge protective 2 ● Current ratings up to 60A External to Electrical electrical distribution device (SPD) that combines ● 2 Distribution Equipment equipment. 120 and 240 Vac units surge suppression ● 24 and 48 Vdc units components and EMI/RFI 2 SPD Series Integrated Units ● DIN mounting available on filtering, providing effective Specification grade surge some models protection for sensitive electronic loads. 2 protective devices installed ● Up to 80 kA of peak surge within Eaton’s electrical protection Surges (also known as assemblies. ● Most AC units are UL 1449 transients), due to lightning, 2 3rd Edition and UL 1283 utility grid switching, 5th Edition listed switching of external/internal 2 inductive or capacitive loads, and other sources, travel on 2 power line conductors throughout the electrical 2 distribution system, causing system operating problems and equipment downtime. 2 SPD Series Sidemount Unit 2 2 2 2 2 SPD Series Integrated Unit 2 SPV Series 2 AEGIS Products 2

V3-T2-2 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

Surge Protection for Sub-Panel and OEM Applications 2 In today’s business Panelboards with Integrated environment that calls for 24 Surge Protective Devices 2 hours a day, 7 days a week ● Available in standard and uptime and reliability, Eaton’s custom configurations 2 CVX050 and CVX100 surge ● Ratings: protective devices (SPDs) ● 120/240 Vac, single- ensure that a customer’s phase, three-wire 2 investment in equipment and processes is protected from ● 208Y/120 Vac, three- 2 the damaging effects of phase, four-wire voltage transients. Designed ● 480Y/277 Vac, three- for installation on service phase, four-wire 2 entrance, branch panels or ● 600Y/347 Vac, three- individual equipment phase, four-wire (other Surge Protective Devices can be 2 Integrated within a variety of Eaton disconnects, the CVX050/100 voltage configurations Electrical Assemblies provides enhanced surge are available) 2 protection for mission-critical applications. ● Copper bus 2 ● 12, 18, 24, 30, 36 and 42 circuits ● Bolt-on branch breakers 2 ● A full range of factory installed modifications 2 and accessories ● Fully rated or series rated 2 Power Conditioning 2 Sag Ride-Through (SRT) Electronic Voltage 2 The sag ride-through (SRT) Regulator (EVR) is a power conditioner that The electronic voltage corrects voltage sags to regulator (EVR) is designed 2 maintain uptime and to meet the needs of productivity. customers who experience 2 voltage regulation problems due to brownout conditions 2 from their electric utilities. 2 2 2 2 Sag Ride-Through (SRT) Electronic Voltage Regulator (EVR) 2

Facility-Wide Power Protection Solutions 2

A facility-wide protection The most accepted design methodology is based on two concepts: 2 approach should be employed to address power 1. Ensure proper grounding conditions exist. 2. Surge protection should be installed 2 quality issues. This approach All forms of power protection/conditioning at key distribution panels and minimizes overall lifecycle rely on good grounding, bonding and critical loads. 2 costs and optimizes facility earthing practices. uptime. The following is a recommended design 2 approach for implementing facility-wide Eaton power 2 protection solutions. 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-3 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Application Description 2 Application Recommendations for Surge Products 2 Application Type Eaton’s Surge Product Features and Competitive Advantages Light Commercial 2 Design build SPD Series integrated units Ideal package for any commercial facility Chain stores SPD Series sidemount units Cost-effective, reliable protection using the SPD Series or SPV units 2 Small facilities SPV units SP1 units 2 CVX units 2 Large Projects Including: SPD Series integrated units in panelboards, switchboards, Able to meet competitors’ surge protection specifications 2 Commercial MCCs, switchgear, busway and automatic transfer switches Increased surge protection performance by using integrated SPD Series units Government SPD Series sidemount units Wall space savings by using integrated SPD Series units 2 Schools SPV units Quick-ship capabilities from Eaton assembly satellites and service centers Institution AEGIS units for critical load applications Power conditioning capability for a wide variety of applications 2 Military Power conditioners (EVR and SRT units) Industrial 2 Including: SPD Series integrated units in panelboards, switchboards, Increased surge protection performance by using integrated SPD Series units Small and large facilities MCCs, switchgear, busway and automatic transfer switches Wall space savings by using integrated SPD Series units 2 WWTP SPD Series sidemount units MCCs with SPD Series units installed protect drives from damage SPV units AEGIS products protect expensive critical loads from harmful damage AEGIS units for critical load applications such as PLCs, EVR units correct voltage regulation problems 2 robotics applications, etc. SRT units correct voltage sag problems 2 Power conditioners (EVR and SRT units) OEM 2 Any OEM customer including: SPD Series integrated units Years of experience in a variety of OEM applications Integrators SPD Series sidemount units Application assistance and recommendations 2 Medical equipment SPV units Small footprint enables integration in a variety of applications Automation and control SP1 units Ability to meet customized requirements 2 CVX units AEGIS units for critical load applications 2 Telecommunications Including: Panelboards and automatic transfer switches with integrated SPD Series units Ability to meet customized requirements 2 Cellular sites SPD Series sidemount units Application assistance and recommendations Microwave SPV units 2 PCS SP1 units 2 Paging systems CVX units 2 2 2 2 2 2 2 2 2

V3-T2-4 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

SPD Series Sidemount Units Contents 2 Description Page Introduction...... V3-T2-2 2 Product Overview SPD Series for Integration into Electrical 2 Distribution Equipment ...... V3-T2-7 SPD Series for Mounting External to 2 Electrical Distribution Equipment ...... V3-T2-11 SPV Surge Protective Device ...... V3-T2-16 CVX050/100 ...... V3-T2-18 2 SP1 Surge Protective Device ...... V3-T2-21 SP2 Surge Protective Device ...... V3-T2-23 2 AEGIS Powerline Filters ...... V3-T2-25 Sag Ride-Through (SRT) ...... V3-T2-30 2 Electronic Voltage Regulator (EVR) ...... V3-T2-36 Learn 2 Online 2 2 2 Product Overview Product Description Features, Benefits and Functions 2 Eaton’s SPD series surge A complete offering of ● Uses self-protected metal Safety Features protective devices are the sidemount units designed oxide varistor (MOV) ● All units use self-protected 2 latest and most advanced for mounting external to technology metal oxide varistor ® UL 1449 3rd Edition certified electrical distribution ● Three feature package technology (MOV) as their 2 surge protectors. Units are equipment is also available. options core surge suppression available integrated within Application of SPD Series ● True protection status component. Usage of this 2 Eaton electrical assemblies, units throughout a facility indicators report the status technology ensures safe including panelboards, will ensure that equipment of the protection elements, operation when the unit is 2 switchboards, motor is protected with the safest not the status of the subjected to abnormal control centers, switchgear, and most reliable surge applied power conditions such as automatic transfer switches protective devices available. 2 ● temporary overvoltage or and bus plugs. SPD Series units are available Available integrated within the following high fault current in all common and conditions. Under such 2 configurations and also Eaton electrical assemblies: panelboards, switchboards, conditions, the self- in a variety of surge current protected MOVs are capacity ratings from 50 motor control centers, 2 switchgear, automatic removed from the circuit through 400 kA. Three quickly and safely before a feature package options are transfer switches and 2 bus plugs potentially unsafe condition also available to choose from, can occur ● 10-year warranty (15-year ensuring the proper unit is ● 2 warranty with registration) SPD Series units contain available for a variety of no replaceable parts such SPD Series Integrated Units applications. as surge modules, fuses, 2 or surge counter memory backup batteries. This 2 prevents potential arc flash and shock hazards, as the units require no periodic 2 service or user intervention after installation 2 ● Integrated versions of the unit are factory installed 2 and sidemount versions are factory sealed. These 2 important safety measures further enhance user 2 safety 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-5 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

Three Feature Package Standard Feature Package Side-By-Side Comparison of the SPD Series’ Available 2 Options Available The standard feature package Feature Packages The SPD Series provides includes all of the features Standard with 2 users with the option of found in the basic feature Feature Package Comparison Basic Standard Surge Counter selecting between three package, plus an audible alarm Surge protection using self-protected ■■ ■ 2 feature packages. These with silence button, EMI/RFI MOV technology feature packages are the filtering, and a form ‘C’ relay ■■ ■ basic, standard and standard contact that can be used for Dual-colored protection status indicators 2 for each phase with surge counter. The remote annunciation of the proper feature package SPD’s status. The audible Dual-colored protection status indicators ■■ ■ 2 can be selected based on alarm activates and the form for the N-G protection mode the requirements of the ‘C’ relay contact changes state Audible alarm with silence button ■■ 2 application or specification. when any loss of protection is Form ‘C’ relay contact ■■ detected or a fault condition A side by side comparison of ■■ exists with the unit. Should EMI/RFI filtering, providing up to 50 dB of 2 the individual features found noise attenuation from 10 kHz to 100 MHz in each package is below. such a condition occur, the audible alarm can be silenced Surge counter with reset button ■ 2 Basic Feature Package by pressing the silence button. The basic feature package is The EMI/RFI filter provides up Standards and Certifications Technical Data 2 perfect for applications where to 50 dB of noise attenuation ● Integrated versions of and Specifications basic, cost-effective, safe and over the range of 10 kHz the unit are UL 1449 ● 20 kA nominal discharge 2 reliable surge protection is through 100 MHz. required, but budgets don’t 3rd Edition recognized current (In) rating allow for extra, additional Standard with Surge components for the (maximum rating 2 features. Rather than Counter Feature Package United States and Canada, assigned by UL) sacrifice performance or The standard with surge covered by Underwriters ● 50 through 400 kA surge 2 safety due to cost, SPD counter feature package Laboratories certification current capacity ratings and follow-up service Series units with the basic includes all of the features ● 200 kA short-circuit current 2 feature package provide you found in the standard feature ● Sidemount versions are rating (SCCR) with high-performing surge package plus a six-digit surge UL 1449 3rd Edition listed 2 protection without sacrificing counter with a reset button. devices and are also safety or reliability. The basic The surge counter indicates CSA approved feature package provides the ongoing count of the 2 the same level of surge number of surges the unit has protection and safety been exposed to and stores 2 provided by the standard and them in nonvolatile memory. standard with surge counter Should power to the SPD 2 feature packages minus Series unit be completely some of the features found in interrupted, the surge counter them. The package contains will recall and display the 2 dual-colored protection status surge count prior to the LEDs that report the true interruption when power is 2 status of the protection in restored. Unlike many surge each phase/mode. All four- protectors, the SPD Series’ 2 wire plus ground units also surge counter memory contain an additional set of feature does not require a 2 dual-colored protection status backup battery that would LEDs that report the status require periodic replacement of the protection in the in order to achieve its 2 neutral/ground mode. memory functionality. 2 2 2 2 2 2 2 2

V3-T2-6 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

SPD Series Unit Integrated within an Eaton Panelboard Contents 2 Description Page Introduction...... V3-T2-2 2 Product Overview ...... V3-T2-5 SPD Series for Integration into Electrical 2 Distribution Equipment Standards and Certifications ...... V3-T2-8 2 Catalog Number Selection...... V3-T2-8 Technical Data and Specifications ...... V3-T2-9 Dimensions ...... V3-T2-10 2 SPD Series for Mounting External to Electrical Distribution Equipment ...... V3-T2-11 2 SPV Surge Protective Device ...... V3-T2-16 CVX050/100 ...... V3-T2-18 2 SP1 Surge Protective Device ...... V3-T2-21 SP2 Surge Protective Device ...... V3-T2-23 2 AEGIS Powerline Filters ...... V3-T2-25 Sag Ride-Through (SRT) ...... V3-T2-30 Electronic Voltage Regulator (EVR) ...... V3-T2-36 2 2 2 SPD Series for Integration into Electrical Distribution Equipment Product Description Application Description 2 Eaton’s SPD Series surge The SPD Series is available as The Integrated SPD protective devices are the an integrated device within Performance Advantage 2 latest and most advanced the following Eaton electrical Installation conductor length UL 1449 3rd Edition certified assemblies: is the single most important 2 surge protectors. SPD Series factor related to an SPD’s ● Panelboards units are available in all performance. Performance ● 2 common voltages and Switchboards decreases as the connected configurations, and also in ● Motor control centers conductor length increases. 2 a variety of surge current ● Switchgear Integrating the SPD within the capacity ratings from ● Automatic transfer electrical assembly provides 50 to 400 kA. switches the best possible surge 2 protection by keeping ● Bus plugs installation conductor lead 2 Features, Benefits lengths as short as possible. Integrating the SPD within In this installation, the SPD Series and Functions is mounted directly to the panelboard’s 2 an electrical assembly can ● bus bars. This type of installation Uses thermally protected decrease let-through will provide the best possible surge metal oxide varistor (MOV) protection by minimizing the 2 voltages by hundreds of volts, connected lead length. technology providing you with the best ● Three feature package possible surge protection for 2 options sensitive electronic loads. ● 10-year warranty 2 Remote Display Mounting Option Available The SPD Series offers the 2 option of mounting its display remotely from the device. 2 This is useful for applications where OEMs or other 2 integrators would like to embed the unit within a piece 2 of equipment and still be able to view its display. 2

The SPD Series is also available as an 2 integrated unit interfaced via a circuit breaker resident in the electrical assembly. This installation keeps 2 connected lead lengths short while providing a means of disconnecting power to the unit quickly and easily. 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-7 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Standards and Certifications ● UL 1449 3rd Edition recognized component 2 for the United States and Canada, covered by 2 Underwriters Laboratories certification and follow-up 2 service ● UL 1283 (Type 2 2 SPDs only) 2 2 2 Catalog Number Selection

2 SPD Series Units Mounted Internal to Electrical Distribution Equipment 2 SPD 250 480D 2 J 2 Series Application—Integrated Units 2 2 SPD = Surge protective device kA Rating A = Panelboards (PRL1a, 2a, 3a, 3E), direct bus mounted 050 = 50 kA per phase Voltage Code B = Switchgear (includes remote display) 080 = 80 kA per phase 240S = 120/240 single split-phase C = Panelboards (PRL1a, 2a, 3a, 3E, 4), switchboards, 2 100 = 100 kA per phase 208Y = 120/208 wye (4W+G) busway 120 = 120 kA per phase 220Y = 127/220 wye (4W+G) J = Motor control centers 160 = 160 kA per phase 400Y = 230/400 wye (4W+G) 2 200 = 200 kA per phase 480Y = 277/480 wye (4W+G) Feature Package 250 = 250 kA per phase 600Y = 347/600 wye (4W+G) 2 300 = 300 kA per phase 240D = 240 delta (3W+G) 1 = Basic 400 = 400 kA per phase 480D = 480 delta (3W+G) 2 = Standard 600D = 600 delta (4W+G) 3 = Standard + surge counter 2 240H = 240 high-leg delta (4W+G) on ‘B’ phase 1

2 Notes 1 Please consult the factory for 240 high-leg delta (4W+G) applications with high leg on ‘C’ phase. 2 Units used in PRL1a, 2a, 3a and 3E panelboard applications are available in 50–200 kA ratings only. Use the ‘C’ option for 2 PRL1a, 2a, 3a and 3E panelboard applications when unit is connected through a circuit breaker. 2 Example: SPD250480D2J = SPD Series, 250 kA per phase, 480D voltage, standard feature package, motor control center application. 2 2 2 2 2 2 2 2 2 2 2

V3-T2-8 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

Technical Data and Specifications 2 2 SPD Series Specifications Description Specification 2 Surge capacity ratings available 50, 80, 100, 120, 160, 200, 250, 300, 400 kA per phase

Nominal discharge current (In) 20 kA (maximum rating assigned by UL) 2 Short-circuit current rating (SCCR) 200 kA SPD type Basic feature package = Type 1 (can also be used in Type 2 applications) 2 Standard and standard with surge counter feature packages = Type 2 Single split-phase voltages available 120/240 2 Three-phase wye system voltages available 120/208, 127/220, 230/400, 277/480, 347/600 2 Three-phase delta system voltages available 240, 480, 600 Input power frequency 50/60 Hz 2 Power consumption (basic units): 208Y, 220Y, 240S, 240D and 240H voltage codes 0.5W 2 400Y, 480Y and 480D voltage codes 1.1W 600Y and 600D voltage codes 1.3W 2 Power consumption (standard and standard with surge counter units): 2 208Y, 220Y, 240S, 240D and 240H voltage codes 0.6W 400Y, 480Y and 480D basic voltage codes 1.7W 2 600Y and 600D voltage codes 2.1W Protection modes Single split-phase L-N, L-G, N-G, L-L 2 Three-phase wye L-N, L-G, N-G, L-L 2 Three-phase delta L-G, L-L Three-phase high-leg delta L-N, L-G, N-G, L-L 2 Maximum continuous operating voltage (MCOV): 240S, 208Y, 220Y and 240H MCOV 150 L-N, 150 L-G, 150 N-G, 300 L-L 2 400Y and 480Y MCOV 320 L-N, 320 L-G, 320 N-G, 640 L-L 600Y MCOV 420 L-N, 420 L-G, 420 N-G, 840 L-L 2 240D MCOV 320 L-G, 320 L-L 2 480D MCOV 640 L-G, 640 L-L 600D MCOV 840 L-G, 840 L-L 2 Ports 1 Operating temperature –40°F through 122°F (–40°C through 50°C) 2 Operating humidity 5% through 95%, noncondensing Operating altitude Up to 16,000 ft (5000m) 2 Seismic withstand capability Meets or exceeds the requirements specified in IBC 2006, CBC 2007 and UBC Zone 4 2 Form C relay contact ratings 150 Vdc or 125 Vac, 1A maximum Form C relay contact logic Power ON, normal state—NO contact = open, NC contact = closed 2 Power OFF or fault state—NO contact = closed, NC contact = open EMI/RFI filtering attenuation Up to 50 dB from 10 kHz to 100 MHz 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-9 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Dimensions Approximate Dimensions in Inches (mm) 2 50–200 kA Integrated Units 2 Mounting 0.22 3x Bus Mounting 8.80 (5.6) 2 (223.5) 4.40 0.19 (111.8) 2 4x Mounting 0.04 2.02 2.02 0.34 (4.8) Bus (1.0) (51.2) (51.2) (8.6)

2 0.95

NEUTRALNEUTRAL NEUTRALNEUTRAL (24.1) 2 5.40 Mounting CAUTION (137.2) SPD Series 2 3.42 Surge Protective Device (86.9) 4.66 3.42 (118.4)

2 (86.9) FORM “C” CONTACTS TORQUE

GROUND NEU/GND

36 IN. LBS. SURGE SURGE GROUND SURGE

SURGE SURGE GROUND 2 GROUND

2.52 3.42 0.22 2 0.26 4x Mounting (64.0) (86.9) (5.6) (6.6) 3.45 Terminals 4x #10–32 x 0.38 DP 2 (87.6) 8.74 Brass Terminals (222.0) 2 9.50 (241.3) 2 250–400 kA Integrated Units 2 Mounting 8.80 2 4x Mounting (223.5) 2.52 3.42

2 (64.0) (86.9)

GROUND GROUND

SURGE SURGE

2 SPD Series

SURGE GROUND Surge Protective Device SURGE 36 IN. LBS. IN. 36 NEU/GND GROUND

3.42 Mounting TORQUE 2 (86.9) 3.42 CONTACTSFORM “C” CAUTION 5.40 (86.9) (137.2) 2 4.66 (118.4)

TORQUE NEU/GND 2 36 IN. LBS. 1.71

NEUTRAL NEUTRALNEUTRAL

2 (43.4) NEUTRAL Terminals 0.22 4.85 4x Mounting 2 (123.2) 8.74 (5.6) (222.0) 5.78 9.50 4x #10–32 x 0.38 DP 2 (146.8) (241.3) Brass Terminals 2 Weights ● 50–200 kA units 2 approximately 3.5 lbs (1.6 kg) 2 ● 250–400 kA units approximately 7.0 lbs 2 (3.2 kg) 2 2

V3-T2-10 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

Eaton SPD Series Sidemount Unit Mounted Externally to an Eaton Panelboard Contents 2 Description Page Introduction...... V3-T2-2 2 Product Overview ...... V3-T2-5 SPD Series for Integration into Electrical 2 Distribution Equipment ...... V3-T2-7 SPD Series for Mounting External to Electrical Distribution Equipment 2 Catalog Number Selection...... V3-T2-12 Technical Data and Specifications ...... V3-T2-13 2 Dimensions ...... V3-T2-14 SPV Surge Protective Device ...... V3-T2-16 2 CVX050/100 ...... V3-T2-18 SP1 Surge Protective Device ...... V3-T2-21 2 SP2 Surge Protective Device ...... V3-T2-23 AEGIS Powerline Filters ...... V3-T2-25 2 Sag Ride-Through (SRT) ...... V3-T2-30 Electronic Voltage Regulator (EVR) ...... V3-T2-36 2 2 2 SPD Series for Mounting External to Electrical Distribution Equipment Product Description Features, Benefits Standards and Certifications 2 Eaton’s sidemount versions and Functions ● UL 1449 3rd Edition of the SPD Series surge ● Uses self-protected metal listed device 2 protective devices are the oxide varistor (MOV) ● Canadian Standards latest and most advanced technology Association (CSA) 2 UL 1449 3rd Edition listed ● Three feature package ● UL 1283 (Type 2 surge protectors. Application options SPDs only) 2 of SPD Series units ● 15-year warranty throughout a facility will ensure that equipment is 2 protected with the safest and most reliable surge protective 2 devices available. Units are All SPD Series sidemount units come available in all common prewired and include a factory- 2 voltages and configurations, installed conduit interface, and also in a variety of surge making installation very easy. current capacity ratings from 2 50 through 400 kA. Three feature package options are 2 also available to choose from. 2 2

All SPD Series units are factory sealed, 2 ensuring that the user/installer has no potential of coming into contact with harmful voltages present 2 inside the unit. 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-11 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Catalog Number Selection

2 SPD Series Units for Mounting External to Electrical Distribution Equipment 2 SPD 250 480D 2 K

2 Series Application—Sidemount Units SPD = Surge protective device kA Rating K = NEMA 1 enclosure 2 2 050 = 50 kA per phase Voltage Code L = NEMA 1 flushmount enclosure 080 = 80 kA per phase 240S = 120/240 single split-phase M = NEMA 1 enclosure with internal disconnect 2 100 = 100 kA per phase 208Y = 120/208 wye (4W+G) N = NEMA 4 enclosure 120 = 120 kA per phase 220Y = 127/220 wye (4W+G) O = NEMA 4 enclosure with internal disconnect 160 = 160 kA per phase 400Y = 230/400 wye (4W+G) P = NEMA 4X enclosure (stainless steel) 2 200 = 200 kA per phase 480Y = 277/480 wye (4W+G) Q = NEMA 4X enclosure with internal disconnect 250 = 250 kA per phase 600Y = 347/600 wye (4W+G) (stainless steel) 300 = 300 kA per phase 240D = 240 delta (3W+G) 2 400 = 400 kA per phase 480D = 480 delta (3W+G) 600D = 600 delta (4W+G) Feature Package 1 2 240H = 240 high-leg delta (4W+G) on ‘B’ phase 1 = Basic 2 = Standard 2 3 = Standard + surge counter Notes 2 1 Please consult the factory for 240 high-leg delta (4W+G) applications with high leg on ‘C’ phase. 2 NEMA 1 flushmount units are available in 50–200 kA ratings only. 2 Example: SPD250480D2K = SPD Series, 250 kA per phase, 480D voltage, standard feature package, housed in NEMA 1 enclosure. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

V3-T2-12 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

Technical Data and Specifications 2 SPD Series Specifications 2 Description Specification Surge capacity ratings available 50, 80, 100, 120, 160, 200, 250, 300, 400 kA per phase 2

Nominal discharge current (In) 20 kA (maximum rating assigned by UL) Short-circuit current rating (SCCR) 200 kA 2 SPD type Basic feature package = Type 1 (can also be used in Type 2 applications) Standard and standard with surge counter feature packages = Type 2 2 Single split-phase voltages available 120/240 2 Three-phase wye system voltages available 120/208, 127/220, 230/400, 277/480, 347/600 Three-phase delta system voltages available 240, 480, 600 2 Input power frequency 50/60 Hz Power consumption (basic units): 2 208Y, 220Y, 240S, 240D and 240H voltage codes 0.5W 400Y, 480Y and 480D voltage codes 1.1W 2 600Y and 600D voltage codes 1.3W 2 Power consumption (standard and standard with surge counter units): 208Y, 220Y, 240S, 240D and 240H voltage codes 0.6W 2 400Y, 480Y and 480D basic voltage codes 1.7W 600Y and 600D voltage codes 2.1W 2 Protection modes Single split-phase L-N, L-G, N-G, L-L Three-phase wye L-N, L-G, N-G, L-L 2 Three-phase delta L-G, L-L 2 Three-phase high-leg delta L-N, L-G, N-G, L-L Maximum continuous operating voltage (MCOV): 2 240S, 208Y, 220Y and 240H MCOV 150 L-N, 150 L-G, 150 N-G, 300 L-L 400Y and 480Y MCOV 320 L-N, 320 L-G, 320 N-G, 640 L-L 2 600Y MCOV 420 L-N, 420 L-G, 420 N-G, 840 L-L 2 240D MCOV 320 L-G, 320 L-L 480D MCOV 640 L-G, 640 L-L 2 600D MCOV 840 L-G, 840 L-L Ports 1 2 Operating temperature –40°F to 122°F (–40°C to 50°C) Operating humidity 5% through 95%, noncondensing 2 Operating altitude Up to 16,000 ft (5000m) 2 Seismic withstand capability Meets or exceeds the requirements specified in IBC 2006, CBC 2007 and UBC Zone 4 Enclosure dimensions and weights Refer to figures on Pages V3-T2-14–V3-T2-15 for enclosure dimensions and weights 2 Form C relay contact ratings 150 Vdc or 125 Vac, 1A maximum Form C relay contact logic Power ON, normal state—NO contact = open, NC contact = closed 2 Power OFF or fault state—NO contact = closed, NC contact = open EMI/RFI filtering attenuation Up to 50 dB from 10 kHz to 100 MHz 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-13 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Dimensions Approximate Dimensions in Inches (mm) 2 50–200 kA Units in a NEMA 1 Rated Enclosure, 50–200 kA Units in a NEMA 1 Rated Flushmount Enclosure, Weight = 6.8 lbs Weight = 6.8 lbs

2 7.28 7.28 (184.9) 1.0 0 (184.9) 2 5.27 (25.4) Flushmount Panel 1.0 0 (133.9) (4) #8–32 Flat Hd Screws 5.27 (25.4) 2 (133.9)

2 10.48 12.05 (306.1) (266.2) 8.00 2 12.05 10.48 11.25 (203.2) (306.1) (266.2) (285.8) 11.25 0.68 0.68 (285.8) 2 5.24 (17.3) 5.24 (17.3) 14.00 (133.1) (133.1) (355.6) 2 Ø0.20 Ø0.20 (Ø5.1) (Ø5.1) 0.78 2 2.00 5.00 7.47 (19.8) 0.11 0.40 (50.8) 0.40 3.48 (127.0) 0.78 (189.7) 2.00 (88.4) (2.8) (10.2) 3.48 (10.2) 7.47 (19.8) (50.8) 4.41 2 (88.4) 1.76 (189.7) 0.98 (112.0) 4.41 (44.7) 11.00 (24.9) 2 (112.0) (279.4)

2 250–400 kA Units in a NEMA 1 Rated Enclosure, Weight = 13.5 lbs 50–400 kA Units in a NEMA 1 Rated Enclosure with Internal Disconnect, Weight = 14.7 lbs 2 1.0 0 5.47 (25.4) 2 (138.9) 6.69 9.14 (169.9) (232.2) 2

12.05 0.66 10.48 12.30 2 (306.1) 11.25 (16.8) (266.2) (312.4) (285.8) 11.50 2 0.67 2.61 10.73 (292.1) 5.24 (17.0) (66.3) (272.5) 2 (133.1) Ø0.20 2.00 2 (Ø5.1) 7.47 2.75 Ø0.20 0.78 (50.8) 0.40 5.76 (189.7) 0.78 (69.9) (Ø5.1) 11.14 (19.8) (10.2) (146.3) (19.8) 5.76 (283.0) 2 6.69 (169.9) (146.3) 6.55 2 (166.4) 2 2 2 2 2 2 2 2

V3-T2-14 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

2 Approximate Dimensions in Inches (mm) 50–200 kA Units in a NEMA 4 or 4X Rated Enclosure, 50–400 kA Units in a NEMA 4 or 4X Rated Enclosure with 2 Weight = 14.6 lbs Internal Disconnect, Weight = 27.5 lbs 2

13.50 SPD Series SPD Series Surge Protective Device Surge Protective Device (342.9) 12.50 12.75 2 (317.5) 11.75 11.98 (323.9) (304.3) (298.5) 12.28 2 10.98 3.12 (311.9) (278.9) 11.28 (79.2)

(286.5)

0.65 Device Protective Surge 2

5.49 Series SPD

0.65 Device Protective Surge (16.5) (139.4) Series SPD (16.5) 2 0.76 3.36 10.18 Ø0.33 2.60 (19.3) (85.3) (258.6) (Ø8.4) 0.76 6.00 12.47 (66.0) 7.68 2 (19.3) (152.4) Ø0.33 (195.1) (316.7) 5.39 8.65 (Ø8.4) (136.9) (219.7) 2 2 250–400 kA Units in a NEMA 4 or 4X Rated Enclosure, Weight = 14.6 lbs 2

SPD Series 2 Surge Protective Device 10.98 11.28 (278.9) (286.5) 2 11.75 12.50 (298.5) (317.5) 2

5.49 0.65 Device Protective Surge (139.4) (16.5) Series SPD 2

4.10 6.00 0.76 (104.1) (152.4) Ø0.33 2 (19.3) 7.68 8.65 (8.4) (195.1) (219.7) 2 2 2 2 2 2 2 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-15 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 SPV Contents Description Page 2 Introduction ...... V3-T2-2 Product Overview ...... V3-T2-5 2 SPD Series for Integration into Electrical Distribution Equipment ...... V3-T2-7 2 SPD Series for Mounting External to Electrical Distribution Equipment...... V3-T2-11 SPV Surge Protective Device 2 Catalog Number Selection...... V3-T2-17 Technical Data and Specifications ...... V3-T2-17 2 Dimensions ...... V3-T2-17 CVX050/100 ...... V3-T2-18 2 SP1 Surge Protective Device ...... V3-T2-21 SP2 Surge Protective Device ...... V3-T2-23 2 AEGIS Powerline Filters ...... V3-T2-25 Sag Ride-Through (SRT) ...... V3-T2-30 2 Electronic Voltage Regulator (EVR)...... V3-T2-36 2 2 SPV Surge Protective Device Features Standards and Certifications ● SurgePlane™ technology ● UL 1449 3rd Edition Listed 2 Product Description to ensure reliability and ● UL 1283 Listed Eaton’s SPV series is a many pieces of equipment, performance by using a ● CSA TIL I-11B 2 commercial grade and light including computers, low impedance copper industrial surge protective programmable logic platform ● CSA C22.2 No.8 2 device (SPD) that combines controllers, and other ● Compact design to enable surge suppression commonly used electrical and close mounting to 2 components and EMI/RFI electronic equipment. Surges electrical distribution filtering, providing effective can wreak havoc on equipment protection for sensitive equipment, causing 2 ● Parallel hybrid filter electronic loads. Surges (also catastrophic failures, process technology known as transients), due to interruptions and premature ● 2 lightning, utility grid aging leading to failure. The Individually fused surge switching, switching of application of SPDs can suppression components 2 external/internal inductive or mitigate problems with ● Status indicator lights to capacitive loads, and other sensitive electronic monitor supply power, sources, travel on power line equipment, keeping the surge suppression 2 conductors throughout the equipment and the related component status electrical distribution system, processes up and running and fusing 2 causing system operating reliably without disruption ● Can be remotely monitored problems and equipment or damage due to surge- using Form C contacts 2 downtime. Use of the SPV related events. ● Audible alarm units can prevent these costly ● Ideal for OEM panel In addition to externally occurrences and equipment applications 2 generated surge events, such damage. Available with six ● as lightning and grid switching, 50 through 200 kA surge surge current capacity current capacity ratings 2 ratings, the SPV can be equipment is also susceptible ● Contains no replaceable installed on the main of light to damage by internally generated surges. In fact, the parts or items that require 2 commercial buildings, on any periodic maintenance subpanel in a facility and in majority of surges are ● any control panel to protect generated internally by 10-year warranty 2 commonly used items, such sensitive electronic Eaton is the leading supplier equipment. as fluorescent lighting ballasts, 2 light dimmers, photocopiers, of power protection Application Description fax machines and variable technology to a number of Fortune 500 companies. We 2 The ever-increasing use of frequency drives. This further reinforces the necessity for have applied our extensive microprocessors and other experience in power quality 2 sensitive electronic facility-wide surge protection applied at all stages of the and have included a number equipment has increased the of innovative features in the necessity for facility-wide electrical distribution system, 2 from the electrical service development of the Eaton surge protection. These SPV series. sensitive electronic entrance down to the single- 2 components are used within phase loads.

V3-T2-16 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

Catalog Number Selection 2

SPV 2 SPV 050 400D 2 K 2

Surge Rating Voltage Code Enclosure 2 050 = 50 kA/phase See table below Display K = NEMA 1 080 = 80 kA/phase 2 = Standard R = NEMA 3R 2 100 = 100 kA/phase (LED/audible alarm) 120 = 120 kA/phase 160 = 160 kA/phase 2 200 = 200 kA/phase 2 Dimensions SPV Voltage Codes Approximate Dimensions in Inches (mm) 2 Nominal Voltages Voltage Code (Use These Codes to 120/208 230/400 277/480 1 2 Complete the Model Number) 240V 499V 480V SPV—NEMA 1 120/240 single/split-phase (3W plus G) 240S — — 0.40 2 Three-phase wye (4W plus G) 208Y 400Y 480Y (10.2) 2.60 2.60 (66.0) (66.0) Three-phase delta (3W plus G) 240D 400D 480D 2

Technical Data and Specifications 2

SPV 11.55 2 (293.4) Description SPV050 SPV080 SPV100 SPV120 SPV160 SPV200 2 Surge current 50 kA 80 kA 100 kA 120 kA 160 kA 200 kA per phase 10.75 10.00 (254.0) 2 Surge current 25 kA 40 kA 50 kA 60 kA 80 kA 100 kA (273.0) per mode Filter attenuation 0–40 dB 0–40 dB 0–40 dB 0–40 dB 0–40 dB 0–40 dB 2 (MIL-STD-220A at 100 kHz) 2 Circuit Surge- Surge- Surge- Surge- Surge- Surge- construction Plane Plane Plane Plane Plane Plane R.0.10 (2.54) 2 UL 1449 3rd Yes Yes Yes Yes Yes Yes 4 Pls. Edition Listed 2 UL 1283 Listed Yes Yes Yes Yes Yes Yes 1.25 Nominal discharge 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA (31.8) 5.00 2 2 current (ln) (127.0) cUL Listed Yes Yes Yes Yes Yes Yes 2 Enclosure NEMA 1 Standard Standard Standard Standard Standard Standard 2 NEMA 3R Optional Optional Optional Optional Optional Optional 2 Short-circuit current 42 kA 42 kA 42 kA 42 kA 42 kA 42 kA Notes 3 rating (SCCR) 1 Contact factory for other configurations: Applicable for 220/380 and 240/415 system voltages. 2 2 Warranty 10 years 10 years 10 years 10 years 10 years 10 years 208Y, 240S, 240D, 400Y and 480Y units rated 10 kA In. 3 5 kA SCCR for 400D and 480D. 2 Physical Specifications Description Specification 2 Operating temp range –40ºC to +60ºC Altitude < 13,000 ft (4000m) 2 Dimensions 5.00 x 11.55 x 2.60 inches (127.0 x 293.4 x 66.0 mm) 2 Weight 3.5 lbs (1.6 kg) 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-17 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 CVX050/100 Contents Description Page 2 Introduction ...... V3-T2-2 Product Overview ...... V3-T2-5 2 SPD Series for Integration into Electrical Distribution Equipment ...... V3-T2-7 2 SPD Series for Mounting External to Electrical Distribution Equipment...... V3-T2-11 SPV Surge Protective Device ...... V3-T2-16 2 CVX050/100 Catalog Number Selection ...... V3-T2-19 2 Technical Data and Specifications ...... V3-T2-19 Dimensions ...... V3-T2-20 2 SP1 Surge Protective Device ...... V3-T2-21 SP2 Surge Protective Device ...... V3-T2-23 2 AEGIS Powerline Filters ...... V3-T2-25 Sag Ride-Through (SRT) ...... V3-T2-30 2 Electronic Voltage Regulator (EVR)...... V3-T2-36 2 2 CVX050/100 2 Product Description Application Description Features, Benefits Standards and Certifications With over two decades of Eaton’s CVX050 and CVX100 and Functions ● UL 1449 3rd Edition for 2 experience in the surge SPDs protect electronic ● Advanced surge path surge protective devices suppression industry and equipment from damaging technology for high fault ● CE marked extensive R&D initiatives, transients. These units are 2 current capacity, low ● Vibration tested IEC Eaton is considered a world suitable for medium and low impedance, high frequency 60255-21-1 and -2 2 leader in surge protective exposure level applications design device (SPD) manufacturing. that require cost-effective, ● Rugged NEMA® 4X (IP65) All of Eaton’s products are high quality system enclosure 2 manufactured in an ISO® protection including: ● Large diameter, self- 9001:2000 and ISO 14001 ● Residential/small business protected metal oxide Note: CE, CSA and UL on 2 certified facility. AC unit only. ● Light industrial varistors provide long life Eaton’s CVX050/100 models and fail-safe operation ● Light commercial 2 are rugged, cost-effective, ● LED monitoring of each ● Branch panel protection high-quality SPDs that feature phase ● OEM applications 2 self-protected MOVs that ● Wide range of voltage eliminate the failure applications from 2 characteristics of standard 100 to 600 Vac and metal oxide varistors. This 48 and 125 Vdc technology results in a fail-safe ● 5-year free replacement 2 device that monitors the warranty status of the metal oxide disk 2 and disconnects itself from the Optional Features power system when the disk 2 is approaching breakdown. ● External mounting feet The CVX050/100 is easy 2 to install adjacent or even internal to electrical 2 equipment. When installing an SPD in a retrofit environment, 2 it is important to mount the device as close to the electrical equipment as 2 possible. Keep the wiring (lead length) between the electrical 2 equipment and SPD as short as possible, and twist or wire 2 tie the conductors together to reduce the wire’s 2 impedance factor.

V3-T2-18 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

Catalog Number Selection 2

CVX050/100 2 CVX 050 - 240S 2

Per Phase Peak Configuration and Voltage Ranges 2 Surge Current 230L = Single-phase—200, 208, 220, 230, 240, 277 Vac 050 = 50 kA 480L = Single-phase—480 Vac 2 100 = 100 kA 240S = Split-phase—100/200, 110/220, 120/240 Vac 240H = Three-phase high leg delta—120/240 Vac 2 208Y = Three-phase wye (star)—100/174, 110/190, 120/208, 127/220 Vac 480Y = Three-phase wye (star)—220/380, 230/400, 240/415, 277/480 Vac 600Y = Three-phase wye (star)—305/525, 347/600 Vac 2 240D = Three-phase delta—200, 208, 220, 230, 240 Vac 480D = Three-phase delta—380, 400, 415, 440, 480 Vac 600D = Three-phase delta—525, 600 Vac (600D available in 50 kA only) 2 048DC = Direct current—48 Vdc 1 125DC = Direct current—125 Vdc 1 2

Technical Data and Specifications 2

CVX050/100 Model Specifications 2 Description Specification 2 Peak kA per phase 50, 100 Peak kA per mode 50 2 Nominal discharge current 20 kA 1 Short-circuit current rating 100 kA 2 Single-phase voltages 200, 208, 220, 230, 240, 277, 380, 400, 440, 460, 480 Vac Split-phase voltages 100/200, 110/220/ 120/240 Vac 2 High leg delta voltages 240 Vac 2 Wye system voltages 100/175, 110/190, 120/208, 127/220, 220/380, 230/400, 240/415, 277/480, 305/525, 347/600 Vac Delta system voltages 200, 208, 220, 230, 240, 380, 400, 415, 440, 480, 525, 600 Vac 2 Direct current Voltage 2 48 Vdc, 125 Vdc Input power frequency 47–420 Hz (50/60 Hz typical) 2 Protection modes Single-phase: L-N, N-G, L-G Split-phase: L-N, N-G, L-G, L-L 2 High leg delta: L-N, N-G, L-G, L-L, H-N, H-G, H-L Wye: L-N, N-G, L-G, L-L Delta: L-G, L-L 2 Direct current 1 (DC): L-L, L-G Number of ports 1 2 Specific energy 100 kJ/Ohm 2 Weight ≈2.0 lbs (1.0 kg) Operating temperature –13°F (–25°C) to +140°F (+60°C) 2 Vibration tested IEC 60255-21-1 and IEC 60255-21-2

Notes 2 1 480L, 600D and 600Y units rated 10 kA In. 2 DC models only available in 50 kA. 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-19 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 CVX050/100 Voltage Ratings 1 System Nominal MCOV UL 1449-3 VPR 2 Model Configuration System Voltage L-L L-N L-G N-G L-L L-N L-G N-G CVX050 2 230L Single-phase two-wire + ground 200, 208, 220, 230, 240, 277 — 320 640 320 — 1200 1200 1200 2 480L Single-phase two-wire + ground 380, 400, 440, 460, 480 — 550 1100 550 — 1800 4000 1800 240S Split-phase three-wire + ground 100/200, 110/220, 120/240 300 150 300 150 1200 700 1200 800 2 208Y Three-phase wye (star) four-wire + ground 100/175, 110/190, 120/208, 127/220 300 150 300 150 1200 700 1200 800 480Y Three-phase wye (star) four-wire + ground 220/380, 230/400, 240/415, 277/480 640 320 640 320 2500 1200 2000 1200 2 600Y Three-phase wye (star) four-wire + ground 305/525, 347/600 840 420 840 420 2500 1500 2500 1500 240D Three-phase delta three-wire + ground 200, 208, 220, 230, 240 640 — 320 — 2000 — 1200 — 2 240H Three-phase high leg delta 240 300 150 150 640 1500 700 1200 700 480D Three-phase delta three-wire + ground 380, 400, 415, 440, 480 1100 — 550 — 3000 — 1800 — 2 600D Three-phase delta three-wire + ground 525, 600 1100 — 700 — 3000 — 2500 — 048DC Direct current 48 Vdc 2 130—65— ———— 2 125DC Direct current 125 Vdc 2 288—144— — — — — CVX100 2 230L Single-phase two-wire + ground 200, 208, 220, 230, 240, 277 — 320 320 320 — 1200 1200 1200 480L Single-phase two-wire + ground 380, 400, 440, 460, 480 — 550 550 550 — 1800 1800 1800 2 240S Split-phase three-wire + ground 100/200, 110/220, 120/240 300 150 150 150 1200 700 800 700 208Y Three-phase wye (star) four-wire + ground 100/175, 110/190, 120/208, 127/220 300 150 150 150 1000 600 700 700 2 480Y Three-phase wye (star) four-wire + ground 220/380, 230/400, 240/415, 277/480 640 320 320 320 1800 1200 1200 1200 600Y Three-phase wye (star) four-wire + ground 305/525, 347/600 840 420 420 420 2500 1500 1500 1500 2 240D Three-phase delta three-wire + ground 200, 208, 220, 230, 240 640 — 320 — 1800 — 1200 — 2 240H Three-phase high leg delta 240 300 150 150 150 1200 700 700 700 480D Three-phase delta three-wire + ground 380, 400, 415, 440, 480 1100 — 550 — 3000 — 1800 — 2 Dimensions 2 Approximate Dimensions in Inches (mm) 2 CVX050/100 Standard Dimensions Conduit Fitting 5.67 (144.0) 0.75 (19.0) Internal 2 4.75 (120.6) Taper Pipe Threads 4.17 (106.0) 2 2 2 3.39 (86.1) 2 4.75 (120.6) A A 2 2.37 (60.2) Lid Removed 1.00 (25.4) 2 3.55 (90.2)

2 0.17 (4.3) (4) Mounting Holes 2 Under Lid 2 Section A-A 2 Mounting Hole Shafts 2 Dimensions are in Inches (mm) Notes 1 UL 1449 3rd Edition VPR (voltage protection rating) test environment: All tests performed with 6-inch lead length, positive polarity. 2 2 DC units available in 50 kA only. Voltages shown are the maximum suggested operating voltages and are not UL certified.

V3-T2-20 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

SP1 Surge Protective Device Contents 2 Description Page Introduction...... V3-T2-2 2 Product Overview ...... V3-T2-5 SPD Series for Integration into Electrical 2 Distribution Equipment ...... V3-T2-7 SPD Series for Mounting External to 2 Electrical Distribution Equipment ...... V3-T2-11 SPV Surge Protective Device ...... V3-T2-16 CVX050/100 ...... V3-T2-18 2 SP1 Surge Protective Device Catalog Number Selection...... V3-T2-22 2 Technical Data and Specifications ...... V3-T2-22 Dimensions ...... V3-T2-22 2 SP2 Surge Protective Device ...... V3-T2-23 AEGIS Powerline Filters ...... V3-T2-25 2 Sag Ride-Through (SRT) ...... V3-T2-30 Electronic Voltage Regulator (EVR) ...... V3-T2-36 2 2 2 SP1 Surge Protective Device Product Description Features Standards and Certifications 2 Eaton‘s SP1 is a UL 1449 3rd Installation and operation of ● Type 1 SPD capable of ● UL 1449 3rd Edition-listed Edition-listed surge protective the SP1 is simple. The unit installation on either the device 2 device that provides reliable, comes pre-wired with 24.00 line or the load side of the cost-effective surge inches of 10-gauge wire and service entrance 2 protection. This Type 1 SPD is mounted via the half-inch disconnect is capable of being installed nipple that is molded into its ● 20 kA nominal discharge 2 on either the line or the load enclosure. Wall or DIN rail current rating (In) on most side of the service entrance mounting can also be models disconnect, and can be used accomplished with the 2 ● 50 kA per phase surge as a replacement for devices addition of an optional kit. current capacity formerly known as secondary When powered, the unit‘s 2 ● surge arresters or lightning light-emitting diode (LED) Compact footprint— arresters, which could not be indicator reports the status of 4.80-inch L x 2.90-inch W x 2 manufactured after UL 1449 the protection elements and 2.50-inch D 3rd Edition went into effect is active when all of them are ● Pre-wired with 24.00 on September 29, 2009. The intact and providing inches of 10-gauge wire 2 unit is available in many protection. Any loss of ● Half-inch nipple molded common voltages and protection is signaled when into enclosure enables 2 configurations. Multiple the LED extinguishes. quick and easy mounting mounting options coupled ● Optional kit enables wall or 2 with a compact footprint DIN rail mounting enables installation of the ● Two-year warrant y 2 SP1 in a wide range of applications, including panel- boards, loadcenters, pump 2 panels, control cabinets, and other electrical assemblies 2 and applications. 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-21 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Catalog Number Selection SP1 2 SP1 - XXXX 2 2 Series Voltage Code 050 = 50 kA 240S = 120/240V single split-phase 100 = 100 kA 208Y = 120/208 wye 2 480Y = 277/480 wye 600Y = 347/600Y wye 2 240D = 240 delta SP1MNTGKIT = optional wall or DIN rail mounting kit 480D = 480 delta 600D = 600 delta 2 (order separately—not included with SP1 unit) 2 Technical Data and Specifications Dimensions 2 Approximate Dimensions in Inches (mm) SP1 SP1 2 Description Ratings 1.35 1/2" (12.7) Surge current capacity per phase 50 kA (34.3) Straight Pipe Thread 2 Nominal discharge current (In) 20 kA for SP1-240S, 208Y, 480Y, 240D and 480D 2 10 kA for SP1-600Y and 600D Short-circuit current rating (SCCR) 200 kA .79 (20.1) 2 SPD type Type 1 (can also be used in Type 2 applications) System voltages available (Vac) 2 Single split-phase 120/240 Three-phase wye 120/208, 277/480, 347/600 2 Three-phase delta 240, 480, 600 3.95 Protection modes (100.3) 2 Single split-phase and three-phase wye L-N, L-L Three-phase delta L-G, L-L 2 Maximum continuous operating voltage (MCOV) SP1-240S and SP1-208Y 150 L-N, 300 L-L 2 SP1-480Y 320 L-N, 640 L-G 2.46 SP1-600Y 420 L-N, 840 L-G 2.89 (73.4) (62.5) 2 SP1-240D 300 L-G, 300 L-L 2 SP1-480D 640 L-G, 640 L-L SP1-600D 840 L-G, 840 L-L 2 Input power frequency 50/60 Hz Enclosure rating NEMA 4 2 Operating temperature –20°C to 50°C (–4°F to 122°F) Operating humidity 5–95%, noncondensing 2 Operating altitude Up to 16,000 ft (5000m) Agency certification and approvals UL 1449 3rd Edition Listed device 2 Warranty 2 years 2 ANSI/UL 1449 3rd Edition Voltage Protection Ratings Protection Mode 2 Catalog Number L-N L-G L-L SP1-240S 600 N/A 1000 2 SP1-208Y 600 N/A 1000 2 SP1-480Y 1200 N/A 2000 SP1-600Y 1500 N/A 2500 2 SP1-240D N/A 1000 1000 SP1-480D N/A 2000 2000 2 SP1-600D N/A 2500 2500

V3-T2-22 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

SP2 Surge Protective Device Contents 2 Description Page Introduction...... V3-T2-2 2 Product Overview ...... V3-T2-5 SPD Series for Integration into Electrical 2 Distribution Equipment ...... V3-T2-7 SPD Series for Mounting External to 2 Electrical Distribution Equipment ...... V3-T2-11 SPV Surge Protective Device ...... V3-T2-16 CVX050/100 ...... V3-T2-18 2 SP1 Surge Protective Device ...... V3-T2-21 SP2 Surge Protective Device 2 Product Selection...... V3-T2-24 Technical Data and Specifications ...... V3-T2-24 2 Dimensions ...... V3-T2-24 AEGIS Powerline Filters ...... V3-T2-25 2 Sag Ride-Through (SRT) ...... V3-T2-30 Electronic Voltage Regulator (EVR) ...... V3-T2-36 2 Surge Protection for Light Commercial and UL 508A Panel Applications 2 2 SP2 Surge Protective Device Product Description Features, Benefits and Standards and Certifications 2 The SP2 provides basic Functions ● UL 1449 Third Edition Type surge protection for light ● Ease of installation— ● Voltage-specific models 1 SPD File No. E109835, 2 commercial electrical Compact design allows protect electrical systems cULus systems and OEM equipment for easy installation on an and equipment, improving ● Built in an ISO 9001 facility 2 requirements. The SP2 is electrical panel or meter performance by more than ● Flammability rating UL 94VO available in the most popular socket, or integrated into 110% over “one-size-fits- ● Designed and tested in 2 voltage and system control cabinets all” economy surge accordance with: configurations and delivers ● Type 1 UL 1449 Third arresters ● IEEE C62.41.1 2 superior surge protection Edition listed SP2s are ● Compact enclosure takes using MOV thermal easily selected and up less space and can be ● IEEE C62.41.2 disconnect technology installed on the loadside installed in tight spaces ● IEEE C62.43-2005 2 that eliminates the need or lineside of the service ● Can be used on single- ● IEEE C62.45-2002 for additional overcurrent entrance overcurrent phase, split-phase, wye, ● IEEE C62.48-2005 2 protection. protective device delta, and high-leg delta ● IEEE C62.62-2010 Application Description ● Thermal disconnect systems 2 By providing surge technology eliminates the ● All SP2 devices are protection, the SP2 can need for additional individually marked with a 2 suppress the transients that overcurrent protection serial number for easy are prevalent throughout the ● Compact UV-resistant tracking and identification 2 power distribution system to NEMA 4X enclosure for ● Two-year warrant y support reliable operations in indoor or outdoor 2 applications including: applications ● LED status indicators ● HVAC systems provide surge protection 2 ● Control panels status at a glance—green ● Automation cabinets when good, red to replace 2 ● Pumping systems ● Lighting systems 2 ● Commercial facilities ● Food processing 2 ● Warehouses 2 ● Retail facilities ● Manufacturing operations 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-23 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Product Selection 2 SP2 Nominal Maximum Continuous Voltage 2 System Operating AC Voltage System Protection Connection Catalog Voltage (MCOV) Type Ratings (VPR) Points Number 2 120 150 Single-phase, two-wire 700 L–N 2 SP2-120 2 240 320 Single-phase, two-wire 1200 L–N 2 SP2-240 120/240 150 Split-phase, three-wire 700 L–N, 1200 L–L 3 SP2-240S 2 240 320 Three-phase delta, three-wire + ground 1200 L–G, 2500 L–L 4 SP2-240D 480 550 Three-phase delta, three-wire + ground 1800 L–G, 3000 L–L 4 SP2-480D 2 120/208 150 Three-phase wye, three-wire + ground 700 L–G, 1200 L–L 4 SP2-208Y 2 277/480 320 Three-phase wye, three-wire + ground 1200 L–G, 2500 L–L 4 SP2-480Y 347/600 420 Three-phase wye, three-wire + ground 1500 L–G, 2500 L–L 4 SP2-600Y 2 2 Technical Data and Specifications Dimensions Approximate Dimensions in Inches (mm)

2 SP2 SP2 Enclosure 2 Description Specification Markets Light commercial and UL 508A panels 1.06 (26.9) Diameter 2 Product warranty 2 years System types Single, split, delta, and wye 1.69 (42.9) 2 Nominal system voltage 120, 208, 240, 480, 600 Vac 3.38 (85.9) Installation Two-, three-, four-wire 1.69 2 (42.9) Maximum continuous operating AC voltage Matched to nominal voltage MCOV 150–550 Vac (see table above) 2.06 2.06 2 (52.3) (52.3) L–N protection Yes (single-phase units) 4.13 2 L–L protection Yes (104.9) L–G protection Yes (three-phase units) 2 3.19 Protection Surges and transients (81.0) SCCR 200 kA 4.06 2 (103.1) Nominal discharge current (8 x 20 μs) In 10 kA 2 Maximum discharge current (8 x 20 μs) Imax 45 kA per phase ¾" NPS Response time tA <25 ns 0.87 2 Voltage protection ratings (VPRs) See table above (22.1) Overcurrent device (if required by local code) Circuit breaker or fuse sized to protect wires per 2 local codes 2 Frequency 50/60 Hz Operating status / fault indication One bi-color LED—green (good) / red (replace) 2 Conductor gauge/length 10 AWG stranded copper / 18 inches Mounting Chase nipple (¾” NPS) 2 Enclosure rating NEMA 4X—UL 94-5VA Degree of protection (installed state) IP20 (finger-safe) 2 Install location Indoor/outdoor 2 Circuit location Lineside/loadside Standards / agency information UL 1449 Third Edition Type 1 Listed SPD— 2 cULus, RoHS compliant Operating temperature –40°C to +65°C 2 Maximum operating altitude 12,000 feet Weight 17 oz (476g) 2

V3-T2-24 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

AEGIS Solutions Contents 2 Description Page Introduction...... V3-T2-2 2 Product Overview ...... V3-T2-5 SPD Series for Integration into Electrical 2 Distribution Equipment ...... V3-T2-7 SPD Series for Mounting External to 2 Electrical Distribution Equipment ...... V3-T2-11 SPV Surge Protective Device ...... V3-T2-16 CVX050/100 ...... V3-T2-18 2 SP1 Surge Protective Device ...... V3-T2-21 SP2 Surge Protective Device ...... V3-T2-23 2 AEGIS Powerline Filters Features, Benefits and Functions ...... V3-T2-26 2 Standards and Certifications ...... V3-T2-27 Catalog Number Selection...... V3-T2-27 2 Technical Data and Specifications ...... V3-T2-28 Sag Ride-Through (SRT) ...... V3-T2-30 Electronic Voltage Regulator (EVR) ...... V3-T2-36 2 2 2 AEGIS Powerline Filters Product Description Application Description 2 Eaton AEGIS™ Series line By providing surge protection No matter where transients Why Should Sensitive Electronic filters and surge protectors and line filtering, AEGIS originate, the application of Loads be Protected? 2 are specifically designed to devices can suppress the AEGIS Series devices will PLC manufacturers and protect sensitive electronics noise and transients help protect sensitive service technicians 2 from hazards that exist within prevalent throughout the electronic equipment recommend the use of power a facility. The AEGIS Series power distribution system to including: line filters and surge 2 hybrid filter reacts instantly to support reliable operations in ● suppressors to prevent changes in voltage regardless applications including: Programmable logic controllers (PLCs) downtime and equipment of phase angle or polarity. In damage due to surges and 2 ● Instrumentation ● comparison to other line Scanning devices electrical line noise. Studies ● filters, this technology Water treatment facilities ● Automatic teller machines have shown that failure to 2 provides a higher level of ● Pulp and paper operations (ATMs) protect sensitive electronic suppression, reliability and ● Refrigeration and heating ● Cash registers loads costs American 2 life expectancy. plants ● Alarm systems manufacturing and ● commercial and service Petrochemical and refinery ● Microprocessor-controlled 2 ● industries over $39 billion per Food processing ● OEM products year in lost time and revenue. ● Textiles ● Robotics Preventing these losses is a 2 ● Automotive assembly ● CAD/CAM systems major cost-saving ● Manufacturing operations ● Control equipment opportunity. 2 ● Medical electronics and devices 2 AEGIS Series devices are 2 available in a variety of common voltages and configurations. 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-25 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Features, Benefits and Functions ● Compact design with ● Five- to ten-year warranty 2 multiple mounting options standard dependent on ● Meets new UL safety model; warranty extended standards for surge and an additional five years if 2 filtering protection registered ● AC models available with The breadth of the AEGIS 2 up to 80 kA surge current Series’ features, options and capacity ratings configurations ensures that The AEGIS PH Series Protects Critical The AEGIS PV Series Protects Critical the correct unit is available Loads up to 20A Loads up to 5A 2 ● DIN rail mounting available on most models for all critical electrical applications, including control 2 ● Contains no replaceable panels, security systems, parts or items that require measurement systems, 2 periodic maintenance lab equipment and other ● Alarm contact available point-of-use applications. 2 AEGIS Summary 2 Specifications PH PV CF CN Voltage 120/240 Vac 120/240 Vac 120/240 Vac 120/240 Vac 2 24/48 Vdc 24/48 Vdc 2 Current range 3–20A 1–5A 10–60A 30A DIN mounting Yes Yes Yes 1 No 2 UL 1283 5th Edition & UL 1449 3rd Edition Yes Yes Yes 2 Yes 2 Filtering Yes Yes Yes No 2 EMI/RFI filtering attenuation at 100 kHz 75 dB 50 dB 40 dB N/A 2 L to G, L to N & N to G protection modes Yes Yes Yes Yes Peak kA per phase / mode 60/30 40/20 80/40 80/40 2 UL nominal discharge current (In) 5 kA 5 kA 5 kA 5 kA UL voltage protection rating (VPR) L–G / L–N 3 330/400 330/400 500/500 500/500 2 Short-circuit current rating (SCCR) 5 kA 5 kA 10 kA 10 kA Alarm contacts Yes No Yes 4 No 2 Standard warranty / registered warranty (years) 10/15 10/15 5/10 5/10 4 2 Communication line protection (UL 497A) No No Yes No

2 AEGIS PH and PV Series Hybrid Powerline Filters

2 Three-Wire Design has Normal and Common Mode Protection (L-N, L-G, N-G) Primary High Series High Secondary Status Optional Surge Frequency Blocking Performance Surge Indicator Form C 2 5 Protection Capacitor Tracking Filter Protection Lights Contacts Power 2 Input Power Output 2 L Normal Normal LED Form C L Mode Mode 2 2 N N

Common Common 2 G Mode Mode G

2 Notes 1 Optional on 10A and 30A models only. 2 2 120 Vac models only. 3 Ratings shown for 120 Vac models, other voltages listed in Technical Data. 4 Optional on 30A and 60A models only. 2 5 Available on the PH Series only. 2

V3-T2-26 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

Standards and Certifications 2 ● UL 1449 Third Edition ● UL 1283 Fifth Edition 2 ● Built in an ISO® 9001 facility 2 ● Designed and tested in accordance with: 2 ● IEEE® C62.41.1 AEGIS Products ● IEEE C62.41.2 2 ● IEEE C62.43-2005 ● IEEE C62.45-2002 2 ● IEEE C62.48-2005 IEEE C62.62-2010 2 2 Catalog Number Selection 2 AEGIS 2 AG 2

Product 2 Family/OEM AG Protection/Filtering Voltage Amperage Options 2 PH = Premium hybrid 120 = 120 Vac 03 = 3A DIN mount standard protection with filtering 240 = 240 Vac 05 = 5A 2 10 = 10A 15 = 15A 20 = 20A 2 PV = Premium protection 120 = 120 Vac 01 = 1A DIN mount standard with filtering 240 = 240 Vac 03 = 3A 05 = 5A 2 CF = Critical protection 120 = 120 Vac 10 = 10A DIN = DIN mount 1 with filtering 240 = 240 Vac 30 = 30A CP =Compact 2 2 024 = 24 Vdc 60 = 60A RJ = Telcom protection 048 = 48 Vdc and Form C status contacts 3 2 CN = Critical protection 120 = 120 Vac 30 = 30A without filtering 240 = 240 Vac 2 024 = 24 Vdc 048 = 48 Vdc 2 Notes 1 Only available for 10A CF version. 2 2 Only available for 10A, 120V CF version. 3 Only available for 30A and 60A CF version. 2 2 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-27 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Technical Data and Specifications 2 AEGIS PH and PV 2 PH 120 Vac PH 240 Vac PV 120 Vac PV 240 Vac Specifications 3, 5, 10, 15, 20A 3, 5, 10, 15, 20A 1, 3, 5A 1, 3, 5A 2 DIN mounting Yes Yes Yes Yes UL 1283 5th Edition and UL 1449 3rd Edition Yes Yes Yes Yes 2 Filtering Yes Yes Yes Yes 2 EMI/RFI filtering attenuation at 100 kHz 75 dB 75 dB 50 dB 50 dB L–G, L–N and N–G protection modes Yes Yes Yes Yes 2 Peak kA per phase/mode 60/30 60/30 40/20 40/20 UL nominal discharge current (In) 5 kA 5 kA 5 kA 5 kA 2 UL voltage protection rating (VPR) L–G / L–N / N–G 330/400/330 600/700/600 330/400/330 600/700/600 MCOV 150 275 150 275 2 Short-circuit current rating (SCCR) 5 kA 5 kA 5 kA 5 kA 2 Alarm contacts Yes Yes No No Standard warranty / registered warranty (years) 10/15 10/15 10/15 10/15 2 Communication line protection (UL 497A) No No No No 2 AEGIS CF 2 CF 24 Vdc CF 48 Vdc CF 120 Vac CF 240 Vac Specifications 10A 10A 10A 10A 10A 10A 30A 60A 10A 10A 30A 60A 2 DIN mounting Yes No Yes No Yes No Yes 1 Yes 1 Yes No No Yes 1 UL 1283 5th Edition and — — — — Yes Yes Yes Yes Yes — — — 2 UL 1449 3rd Edition UL 1283 4th Edition — — — — — — — — — Yes Yes Yes 2 Filtering Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes EMI/RFI filtering attenuation 40 dB 40 dB 40 dB 40 dB 40 dB 40 dB 40 dB 40 dB 40 dB 40 dB 40 dB 40 dB 2 at 100 kHz L–G, L–N and N–G Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 2 protection modes 2 Peak kA per phase/mode 6/2 6/2 20/6 20/6 30/10 40/20 80/40 80/40 30/10 24/8 56/24 56/24 UL nominal discharge N/A N/A N/A N/A 3 kA 5 kA 5 kA 5 kA 3 kA N/A N/A N/A current (In) 2 UL voltage protection rating N/A N/A N/A N/A 500/500/500 500/500/500 500/500/500 500/500/500 900/800/900 N/A N/A N/A (VPR) L–G / L–N / N–G 2 MCOV 30 30 50 50 150 150 150 150 275 275 275 275 Short-circuit current 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 2 rating (SCCR) 2 Alarm contacts No No No No No No No No No No No No Standard warranty / 5/10 5/10 5/10 5/10 5/10 5/10 5/10 5/10 5/10 5/10 5/10 5/10 registered warranty (years) 2 Communication line No No No No No No Yes 1 Yes 1 No No Yes 1 Yes 1 2 protection (UL 497A) Note 2 1 Optional. 2 2 2 2

V3-T2-28 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

AEGIS CN 2 24 Vdc 48 Vdc 120 Vac 240 Vac Specifications 30A 30A 30A 30A 2 DIN mounting No No No No UL 1283 5th Edition and UL 1449 3rd Edition — — Yes — 2 UL 1283 4th Edition — — — Yes Filtering No No No No 2 EMI/RFI filtering attenuation at 100 kHz N/A N/A N/A N/A 2 L–G, L–N and N–G protection modes Yes Yes Yes Yes Peak kA per phase/mode 20/6 46/20 80/40 56/24 2 UL nominal discharge current (In) N/A N/A 5 kA N/A UL voltage protection rating (VPR) L–G / L–N / N–G N/A N/A 500/500/500 N/A 2 MCOV 30 50 150 275 Short-circuit current rating (SCCR) 10 kA 10 kA 10 kA 10 kA 2 Alarm contacts No No No No 2 Standard warranty / registered warranty (years) 5/10 5/10 5/10 5/10 Communication line protection (UL 497A) No No No No 2 2 Maximum EMI/RFI Attenuation—MIL-STD-220 Maximum 2 Attenuation Model 10 kHz 100 kHz 1 MHz 10 MHz 100 MHz Frequency 2 AGPH120AG 30 dB 74 dB 76 dB 37 dB 36 dB 101 dB at 0.5 MHz AGPV120AG 27 dB 56 dB 55 dB 36 dB 28 dB 66 dB at 0.085 MHz 2 AGCF12010-CP 16 dB 35 dB 62 dB 40 dB 50 dB 68 dB at 1.25 MHz AGCF12010-DIN 16 dB 35 dB 56 dB 29 dB 51 dB 66 dB at 0.7 MHz 2 AGCF12010 17 dB 35 dB 64 dB 33 dB 51 dB 64 dB at 1.0 MHz 2 AGCF12030 24 dB 44 dB 58 dB 42 dB 53 dB 67 dB at 0.6 MHz AGCF12060 20 dB 48 dB 53 dB 29 dB 46 dB 69 dB at 0.4 MHz 2 2 Let-Through Voltages Based on IEEE Std. C62.62-2010 Testing Waveforms 1 AEGIS Series 2 Test Impulse AGPH120AG AGPV120AG AGCF12010 AGCF12010-DIN AGCF12010-CP AGCF12030AGx AGCF12060AGx AGCN12030 IEEE Category A 25V 30V 150V 300V 300V 150V 90V 400V 2 100 kHz ring wave 6000V, 200A 2 IEEE Category B 35V 40V 330V 400V 400V 330V 230V 500V 100 kHz ring wave 6000V, 500A 2 IEEE Category B 360V 370V 470V 480V 460V 460V 450V 460V combination wave 2 6000V, 3000A (UL 1449-3 VPR) 2 Note 1 All tests conducted on 120 Vac units. 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-29 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Sag Ride-Through (SRT) Contents Description Page 2 Introduction ...... V3-T2-2 Product Overview ...... V3-T2-5 2 SPD Series for Integration into Electrical Distribution Equipment ...... V3-T2-7 2 SPD Series for Mounting External to Electrical Distribution Equipment...... V3-T2-11 SPV Surge Protective Device ...... V3-T2-16 2 CVX050/100 ...... V3-T2-18 SP1 Surge Protective Device ...... V3-T2-21 2 SP2 Surge Protective Device ...... V3-T2-23 AEGIS Powerline Filters ...... V3-T2-25 2 Sag Ride-Through (SRT) Application Description ...... V3-T2-31 2 Features, Benefits and Functions ...... V3-T2-31 Catalog Number Selection...... V3-T2-32 Technical Data and Specifications ...... V3-T2-33 2 Dimensions ...... V3-T2-35 2 Electronic Voltage Regulator (EVR)...... V3-T2-36 2 Sag Ride-Through (SRT) 2 Product Description Eaton’s sag ride-through is Today’s industrial and large Depending on the proximity Regularity of Voltage Sags 2 the first of its kind. commercial to the fault, which can be EPRI conducted a two-year customers are becoming hundreds of miles away, study of power quality levels The SRT power conditioner more sensitive to power the voltage during the sag 2 prevents expensive on distribution systems in the disturbances and are is typically 40%–90% of United States. A variation electrical downtime. The demanding better electric nominal utility voltage. The 2 SRT represents Eaton’s event was recorded every quality. However, the quality operation of circuit breakers, time the voltage dropped state-of-the-art solution to of power grids is not fuses and reclosers limits today’s power conditioning below 90% of the nominal. 2 significantly improving. most sags to less than The results are shown below. challenges. Customers still experience 15 cycles. 2 power quality problems A typical distribution system The Problem—Voltage Sags that affect plant operations Voltage sags are experienced customer experiences about and Brownouts 2 and profitability. 10 to 20 times more 50 events per year when the The ability of a plant to frequently than complete voltage drops below 90%, ride-through voltage sags Deep, Single-Phase Sag outages. However, voltage and only about two events 2 can have a significant sags are equally disruptive per year when the voltage Input A Input A Input A impact on operations and to sensitive equipment. drops below 30% of nominal. competitiveness. In the 600 2 400 Voltage Sags The utility study concluded United States, voltage sags 200 that sags represented almost 0 2 cost billions of dollars in 1. Fault occurs on all of the events experienced lost production, interruption, -200 the transmission -400 Generation or distribution at a typical facility. damaged materials, retooling -600 system 2 and scrap. In addition, Events per Year sags can cause: increased End Definition of Voltage Sag Users 2 operating costs, the need Transmission 6 for product reworks, safety A voltage sag is a sudden, Distribution 2 hazards, equipment damage momentary decrease in 5 and/or failure, reduced supply voltage. It can last 2. Creates a sag 4 product quality, increased from a cycle to several Feeder event for all 2 Breakers users on the 3 clean-up, additional labor seconds. Voltage sags are End system costs, increased scrap most often caused by faults User 2 2 material and costs associated on the electrical transmission 1 End User 60 – 70 with investigations into or distribution system. They 0 30 – 40 6 – 10 can be caused by lightning 5 4 3 2 the problem. 2 1 strikes, animal contact, 20 – 1050 – 206 – 10 2 starting of large motors or an internal fault within 2 a customer’s facility. 2

V3-T2-30 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

Application Description Features, Benefits and Functions 2 Industries and Applications Sag Correction Using the SRT Continuous Regulation Affected by Sags The SRT is a high The Sag Ride-Through is an 2 Key industries: Equipment or processes: performance, inverter- active voltage conditioner. based voltage conditioning This means it will constantly 2 ● Semi-conductor ● Manufacturing process device developed to provide respond to voltage sags and manufacturers controllers protection to sensitive loads swells in the +/–10% range 2 ● Communications ● Variable speed drives against commonly occurring with a regulated output in the ● Steel mills ● Robotics voltage sags. +/–1% range. The SRT can be 2 ● Petroleum and chemical ● Motor conductor applied to the main service The SRT monitors the processing ● entrance, at branch locations Telephone systems incoming supply voltage and 2 ● or in front critical loads. The Health care ● HID lighting when it deviates from the ● SRT provides an outstanding Paper mills ● HVAC controls nominal voltage level, the return on investment. It 2 ● Automotives ● Medical equipment SRT achieves voltage delivers operation productivity ● conditioning by injecting the Textile ● Computers that is just not possible with appropriate correction voltage 2 ● Printing traditional tap switching or in series with the power ferroresonant technologies. ● Plastics supply. The SRT provides an The SRT consists of a voltage 2 ● Other manufacturing extremely fast reaction time source inverter, bypass circuit and subcycle response to sag and an injection transformer 2 events that would otherwise Block Diagram of the SRT Active Voltage Conditioner connected in series between cause loads to drop out. the incoming utility supply 2 The SRT is designed for low and the load, as shown in voltage systems (600 to 208, the figure below. For the 2 three-phase) and is also standard sag correcting offered in medium voltage model, the injection 2 3-Phase Compensating applications from up to 50 transformer consists of a Voltage boost component. The SRT Secondary MVA. Installation is simple 3-Phase 3-Phase and the SRT provides monitors the incoming supply 2 Injection Utility Load customers with a new voltage and when it deviates Supply Distribution Primary Transformer Voltage Transformer solution to improve from the nominal voltage 2 productivity and reduce level the SRT inserts an appropriate compensating Bypass Circuit downtime for sag related 2 SRT Input problems. voltage using the IGBT SRT Output inverter and series injection The SRT meets the transformer. Energy is 2 Voltage Source stringent requirements sourced from the supply Inverter of the Semi-F47 standard; during this time. This 2 a key requirement for SAG regulates the load voltage correction in the semi- to its nominal value, 2 conductor industry. thus eliminating voltage disturbances from the utility ● Complete correction supply affecting the load. 2 of single-phase voltage sags down to 63% for 2 30 seconds ● Partial correction of three- 2 phase sags down to 50% for 30 seconds 2 ● Correction of utility voltage unbalance (from network side of transformer) 2 ● Attenuation of voltage flicker 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-31 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Catalog Number Selection

2 SRT2 2 SRT2 1200 480 A A – TC

2 Load kVA, 30% Load kVA, 40% Options 0150 0600 1500 0150 0600 1500 Voltage Frequency Correction Blank = None 2 2 0200 0800 2000 0225 0750 1800 208 A = 60 Hz A = 40% (+10/–40%) TC = Terminal cabinet 0300 1000 2400 0300 0900 480 B = 50 Hz 1 B = 30% (+10/–30%) 0400 1200 0450 1200 600 2 Three-phase/three-wire

2 Notes 1 For 50 Hz international applications, consult factory. 2 2 Terminal cabinet required on all units 200 kVA and larger except when a bypass is required. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

V3-T2-32 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

Technical Data and Specifications 2 SRT Specifications 2 Description Specifications Load Capacity 2 Capacity (kVA) 150 kVA to 50 MVA (as specified per model) Displacement power factor of connected load 0–1, leading or lagging 2 Crest factor for rated kVA 2.0 at 100% of rated load for continuous operation (including up to 10% voltage correction) 2 Overload—30 seconds 150% with up to 10% of voltage correction Input Supply 2 Nominal supply voltage 208/480/600V, 60 Hz three-phase, three-wire plus ground (higher system voltages supplied to requirement up to 36 kV) Maximum supply voltage 110% of nominal supply voltage 2 Minimum three-phase supply voltage Running 50% of nominal supply voltage 2 Starting 1 75% of nominal supply voltage 2 Minimum single-phase-to-ground supply voltage 2 Running 25% of nominal supply voltage 2 Starting 1 63% of nominal supply voltage Efficiency of system 98–99% 2 Output Supply 2 Nominal voltage (V) 208/480/600V, 60 Hz; three-phase, three-wire plus ground (higher system voltages supplied to requirement) Three-phase balanced correction +30% for at least 30 seconds for 100% correction 2 Single-phase-to-ground correction 2 +45% for at least 30 seconds; +10% continuous three-phase correction (all models). Consult factory for specialist correction requirements. Voltage regulation ±1% up to 10% continuous three-phase correction ±2.5% at 30% three-phase correction 2 Response (to sag event) Initial sag correction applied within 1 ms, remainder over the next cycle Response to swell event ±1% up to a 10% continuous three-phase correction with initial swell correction applied within 1 ms, remainder over the next cycle 2 Bypass 2 Nominal power SRT rating (kVA) Maximum overload capacity (in bypass): 2 For 10 minutes (%) 125 For 1 minute (%) 150 2 For 600 milliseconds (%) 700 For 100 milliseconds (%) 1000 2 Transfer time 3 2 Inverter to bypass (ms) <0.5 Bypass to inverter (ms) <40–750 2 Environmental Operating temperature 32°F to 104°F (0 to 40°C); 122°F (50°C) maximum with 20% load derating 2 Cooling Forced ventilation 2 Capacity derating with elevation –1.2% every 100m above 1000m Humidity <95%, noncondensing 2 Warranty 1 year

Notes 2 1 If SRT has tripped (offline) due to below threshold input voltages, it cannot be restarted until the system voltage is at least this % of the nominal. 2 Single-phase-to-ground fault occurring on the utility side of a delta-wye distribution transformer. 2 3 The SRT provides continuous correction and only transitions to and from bypass when manually starting and stopping or under fault or overload conditions. The transition from bypass to inverter takes up to 750 ms. The autoresettable bypass mode of operation includes an additional 5-second delay allowing time for the fault to clear. 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-33 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 2 System Capacities 2 Load Capacity at Normal Fault System System Dissipation Airflow Model Number Voltage 480V (kVA) Capacity (kVA) Efficiency (%) (Worst Case) (kW) (mm3/min) 2 40% Correction SRT20150480AA 150 40 97.55 3.8 18 2 SRT20225480AA 225 40 97.77 5.2 18 SRT20300480AA 300 40 98.00 6.1 18 2 SRT20450480AA 450 40 98.22 8.0 36 2 SRT20600480AA 600 40 98.44 9.8 36 SRT20750480AA 750 40 98.44 12.2 54 2 SRT20900480AA 900 40 98.55 13.2 54 SRT21200480AA 1200 40 98.55 18.1 72 2 SRT21500480AA 1500 50 98.77 20.22 90 2 SRT21800480AA 1800 50 98.88 22.11 108 30% Correction 2 SRT20150480AB 150 40 98.55 2.85 18 SRT20200480AB 200 40 98.55 3.80 18 2 SRT20300480AB 300 40 98.66 5.20 18 SRT20400480AB 400 40 98.88 6.10 18 2 SRT20600480AB 600 40 99.00 8.00 36 2 SRT20800480AB 800 40 99.11 9.80 36 SRT21000480AB 1000 40 99.11 12.20 54 2 SRT21200480AB 1200 40 99.33 13.20 54 SRT21500480AB 1500 40 99.22 18.10 72 2 SRT22000480AB 2000 50 99.33 20.20 90 2 SRT22400480AB 2400 50 99.44 22.11 108 2 2 2 2 2 2 2 2 2 2 2 2 2

V3-T2-34 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

Dimensions 2 Approximate Dimensions in Inches (mm) 2 SRT2, SRT and SRTS Cabinet Dimensions 2 Model Number Height Width Depth SRT2 40% Correction 2 SRT20150480AA 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) SRT20225480AA 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 2 SRT20300480AA 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 2 SRT20450480AA 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) SRT20600480AA 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 2 SRT20750480AA 85.00 (2159.0) 96.00 (2438.4) 96.00 (2438.4) SRT20900480AA 85.00 (2159.0) 96.00 (2438.4) 96.00 (2438.4) 2 SRT21200480AA 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) 2 SRT21500480AA 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) SRT21800480AA 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) 2 SRT2 30% Correction SRT20150480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 2 SRT20200480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) SRT20300480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 2 SRT20400480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 2 SRT20600480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) SRT20800480AB 85.00 (2159.0) 64.00 (1625.6) 32.00 (812.8) 2 SRT21000480AB 85.00 (2159.0) 96.00 (2438.4) 32.00 (812.8) SRT21200480AB 85.00 (2159.0) 96.00 (2438.4) 32.00 (812.8) 2 SRT21500480AB 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) SRT22000480AB 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) 2 SRT22400480AB 85.00 (2159.0) 126.00 (3200.4) 96.00 (2438.4) 2 2 2 2 2 2 2 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-35 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.1 Surge Protection and Power Conditioning

2 Electronic Voltage Regulator (EVR) Tap Changer Contents Description Page 2 Introduction ...... V3-T2-2 Product Overview ...... V3-T2-5 2 SPD Series for Integration into Electrical Distribution Equipment ...... V3-T2-7 2 SPD Series for Mounting External to Electrical Distribution Equipment...... V3-T2-11 SPV Surge Protective Device ...... V3-T2-16 2 CVX050/100 ...... V3-T2-18 SP1 Surge Protective Device ...... V3-T2-21 2 SP2 Surge Protective Device ...... V3-T2-23 AEGIS Powerline Filters ...... V3-T2-25 2 Sag Ride-Through (SRT) ...... V3-T2-30 Electronic Voltage Regulator (EVR) 2 Catalog Number Selection...... V3-T2-37 Technical Data and Specifications ...... V3-T2-37 2 2 2 Electronic Voltage Regulator (EVR) 2 Product Description Features and Benefits Eaton’s Electronic Voltage Brownouts The Solution ● Coordinated with standard 2 Regulator (EVR) is the ideal In the United States, most Prior to installing an expensive thermal-magnetic breakers solution for keeping your facilities have sufficient solution, Eaton encourages to allow motor starts 2 facility and equipment up and voltage regulation. However, customers to monitor ● Optional 50 kA or 100 kA running during brownouts, in some U.S. locations and incoming voltage to per phase surge protection undervoltage conditions and 2 many developing countries, determine if voltage ● Input frequency range other power problems. The regulation problems occur regulation is a problem. operation from 57–63 Hz EVR can significantly reduce because of overstressed The local utility may also be ● Integral manual rotary 2 the costs of equipment utility distribution systems. able to provide information maintenance bypass damage and downtime on voltage expected at switch standard on 50 to 2 when these situations occur. In some cases, due to the the facility. The state-of-the-art design excessive demand on the 500 kVA units and optional 2 provides rapid response time, utility system, voltage may Using a meter, it can quickly on smaller units high efficiency, high inrush be below 10% of nominal be determined if a voltage ● Not affected by load power current capability, and (–10%) during the day. This regulation problem or factor. Can operate 2 operating advantages condition is called a voltage brownout condition exists. effectively in low-load exclusive to Eaton. regulation or brownout. The appropriate solution applications due to “unique 2 Customers may notice dim would be an EVR. EVRs can leakage reactance” The EVR maintains a tightly lights and reduced power. be installed at the service technology regulated output voltage by 2 During the evening, voltage entrance, branch panel or ● Fail-safe bypass circuit, automatically activating the may rise above 10% of at critical loads. isolation transformer appropriate transformer tap nominal (+10%) because 2 Eaton’s EVR is a solid-state and overtemperature through a silicone controlled large facilities and loads are protection rectifier (SCR). Tap changer shut down. This shutdown tap changing power ● Less than 1% THD 2 response time is initiated at reduces the power demand conditioner designed to one cycle, ensuring rapid on the grid and results in a protect against brownouts ● Optional Standard and 2 and precise regulation. voltage increase. and long duration voltage Premium metering to Switching at zero current regulation problems. monitor voltage, current, enables noise reduction The IEEE defines voltage frequency, power, energy, 2 during tap transitions. regulation as overvoltage PF with minimum or undervoltage. Voltage and maximum, and 2 regulation events last from communication capabilities a few minutes to many 2 hours with voltage varying by ±20%. Long-term regulation problems differ 2 from short duration sags and dips, which are much deeper 2 voltage drops. 2

V3-T2-36 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Surge Protection and Power Conditioning 2.1

Catalog Number Selection 2 EVR 2 EVR XXX XXXX XXXX X X XX X 2

kVA Ratings and Dimensions Options 2 1 Weight BTUs/ Dimensions in Inches (mm) B = Bypass switch kVA Lbs hr Bypass Metering (W x D x H) M1 = Standard metering (IQ 130) M2 = Premium metering (IQ 150) 2 010 440 1,025 Optional No 30.20 x 22.20 x 29.00 (767.1 x 563.9 x 736.6) 010 520 1,205 Optional Yes 44.20 x 22.20 x 29.00 (1122.7 x 563.9 x 736.6) Nominal Input 015 465 1,540 Optional No 30.20 x 22.20 x 29.00 (767.1 x 563.9 x 736.6) Voltage Surge Protection 2 015 700 1,540 Optional Yes 44.20 x 22.20 x 29.00 (1122.7 x 563.9 x 736.6) (Delta Input: L, L, L, G) X = No 025 700 2,560 Optional Yes 44.20 x 22.20 x 29.00 (1122.7 x 563.9 x 736.6) S = Yes 2 030 720 3,090 Optional Yes 44.20 x 22.20 x 29.00 (1122.7 x 563.9 x 736.6) 208D = 208 045 950 4,600 Optional Yes 44.30 x 45.90 x 29.00 (1125.2 x 1165.9 x 736.6) 240D = 240 050 1,176 7,332 Yes Yes 66.00 x 29.00 x 35.50 (1676.4 x 736.6 x 901.7) 400D = 400 Frequency 2 075 1,575 9,514 Yes Yes 76.00 x 34.40 x 35.50 (1930.4 x 873.8 x 901.7) 480D = 480 A = 60 Hz 100 2,014 11,833 Yes Yes 76.00 x 34.40 x 35.50 (1930.4 x 873.8 x 901.7) 600D = 600 B = 50 Hz 125 2,137 14,748 Yes Yes 76.00 x 34.40 x 35.50 (1930.4 x 873.8 x 901.7) 2 150 2,240 17,698 Yes Yes 76.00 x 34.40 x 35.50 (1930.4 x 873.8 x 901.7) Nominal Output 225 3,300 23,000 Yes Yes 77.40 x 56.00 x 41.50 (1966.0 x 1422.4 x 1054.1) Voltage 2 300 4,000 30,750 Yes Yes 77.40 x 56.00 x 41.50 (1966.0 x 1422.4 x 1054.1) (Wye Output: 500 5,500 51,250 Yes Yes 77.00 x 72.40 x 48.40 (1955.8 x 1839.0 x 1229.4) L, L, L, N, G) 2 208Y = 120/208 400Y = 230/400 480Y = 277/480 2 600Y = 347/600 2 Technical Data and Specifications 2 EVR Specification (10 to 500 kVA) 2 Feature Description Technology Electronic tap changer 2 Input voltages 208–600V, three-phase (three-wire) Input voltage range +10% to –23% of nominal rated input 2 Output voltage ±3% of nominal Response time 1/2 cycle 2 Frequency 60 Hz, ±3% Efficiency 97% typical 2 Line regulation Output is ±3% of nominal for input variations of +10% to –23% of nominal Load regulation Output is maintained within 3% of nominal from no load to full load 2 Correction time Output will be corrected to within ±3% of nominal in 1.5 cycles or less Harmonic distortion Less than 1.0% added to the output waveform under any dynamic linear loading conditions presented to the line regulator 2 Noise attenuation Common mode 146 dB 2 Normal mode 3 dB down at 1000 Hz, 40 dB/decade to below 50 dB with resistive load Turn-on characteristics When energized, voltage overshoot will be less than 5% of nominal for 1 cycle or less 2 Overload rating 1000% for 1 cycle and 200% for 10 seconds Ambient rating –10° to 40°C 2 Monitoring Three green LEDs (phase power on indication), one red LED (alert indication) Surge protection (optional) CVX 50 kA SPD device 50 kVA and below, CVX 100 kA SPD device 75 kVA and above 2 Input breaker MCCB rated 125% of full rated current Bypass switch Normal and bypass selector 2 Metering (optional) Standard metering (IQ 130)—voltage and current with minimum and maximum Premium metering (IQ 150)—voltage, current, frequency, power, energy, PF, with minimum and maximum, communications capabilities 2 Warranty 1-year parts 2 Notes 1 Bypass is standard on 50 kVA and larger units and an option on 45 kVA and smaller units. The ‘B’ is not included in the part number for units 50 kVA and larger. 2 All weights are approximate. Monitor option includes main input circuit breaker. Refer to PAD for pricing and availability. 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-37 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Capacitor Cell With M12 Threaded Mounting Bolt, Washer, Nut Contents Description Page 2 Product Overview Product Selection ...... V3-T2-39 2 Dimensions ...... V3-T2-40 UNIPUMP ...... V3-T2-41 2 UNIPAK ...... V3-T2-44 AUTOVAR 300 Automatic Power Factor Correction 2 Capacitor Systems...... V3-T2-55 AUTOVAR 600 Automatic Power Factor Correction 2 Capacitor Systems...... V3-T2-58 AUTOVAR Filter—LV Automatic Harmonic Filter . . V3-T2-63 Transient-Free Static Switching Power Factor 2 Correction Units...... V3-T2-67 Active-Harmonic Filter-Harmonic Correction Unit— 2 NEMA 1 Enclosure ...... V3-T2-71 2 2 2 Product Overview 2 Product Description Eaton’s power factor There are several reasons When capacity becomes a Harmonic Filtering 2 correction capacitors and to correct poor power factor. problem, the choice of a As the world becomes more harmonic filters are an The first is to reduce or solution will be dependent dependent on electric and 2 essential part of modern eliminate a power factor upon the size of the increase electronic equipment, the systems. penalty charged by the utility. needed. Like all power likelihood that the negative 2 Power factor correction Another reason is that your quality solutions, there impact of harmonic distortion capacitors are the simplest existing transformer is, or are many factors that need increases dramatically. The and most economical shortly will be, at full capacity to be considered when efficiency and productivity 2 means of increasing the and installing power factor determining which solution gains from these increasingly capacity of any power correction capacitors can will be best to solve your sophisticated pieces of 2 system, minimizing energy be a very cost-effective power factor problem. equipment have a negative losses and correcting load solution to installing a brand side effect…increased 2 power factor. In addition, new service. Depending on harmonic distortion in the power factor penalties can the amount of power factor power lines. The difficult 2 be reduced and power quality correction (kVAR that needs thing about harmonic can be greatly enhanced. to be injected into the distortion is determining the electrical system to improve cause. Once this has been 2 the power factor) and the determined, the solution dynamic nature of the load, can be easy. Passive and 2 a fixed or switched capacitor active harmonic filtering bank may be the best equipment will mitigate 2 solution. specific harmonic issues, and correct poor power 2 factor as well. 2 2 2 2 2 2 2

V3-T2-38 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Product Selection 2

1543PCRMA Capacitor Cell Chart Harmonic Rated Capacitor Cell Chart 2 Voltage kVAR Part Number Voltage kVAR Part Number 240 1.5 643PCRMA 240 12.5 12X23PHRMA 2 240 2 8B43PCRMA 480 15.0 1543PHRMA 240 2.5 1043PCRMA 480 25.0 2543PHRMA 2 240 3 12X43PCRMA 600 12.3 12A63PHRMA 2 240 4 423PCRMA 600 14.7 14S63PHRMA 240 5 2043PCRMA 600 16.7 16S63PHRMA 2 240 6.3 6B23PCRMA Note 240 7.5 7X23PCRMA kVAR rating standard. NEMA kVAR tolerance is +15% to 0%. Part number shown is for 2 three-phase units. Up to 5 kVAR at 480V—fast-on terminals are standard. Above 5 kVAR at 480V 240 8.3 8B23PCRMA (and on all other voltages)—sigut terminals are standard. For dimensions and weights, see following page. 240 10 1023PCRMA 2 240 12.5 12X23PCRMA 2 240 15 1523PCRMA 240 16.7 16S23PCRMA 2 240 17.5 17X23PCRMA 480 1.5 1X43PCRMA 2 480 2 243PCRMA 2 480 2.5 2X43PCRMA 480 3 343PCRMA 2 480 4 443PCRMA 480 5 543PCRMA 2 480 6 643PCRMA 480 7.5 7X43PCRMA 2 480 8.3 8B43PCRMA 2 480 9 943PCRMA 480 10 1043PCRMA 2 480 12.5 12X43PCRMA 480 15 1543PCRMA 2 480 18 1843PCRMA 480 20 2043PCRMA 2 480 25 2543PCRMA 2 480 30 3043PCRMA 600 5 563PCRMA 2 600 7.5 7X63PCRMA 600 10 1063PCRMA 2 600 12.5 12X63PCRMA 2 600 15 1563PCRMA 600 17.5 2063PCRMA 2 600 20 2563PCRMA 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-39 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Dimensions Approximate Dimensions in Inches (mm) 2 Capacitor Cell Chart Harmonic Rated Capacitor Cell Chart 2 Part Number Depth Height Weight in Lbs (kg) Part Number Depth Height Weight in Lbs (kg) 643PCRMA 3.10 (78.7) 7.90 (200.7) 1.1 (0.5) 12X23PHRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 2 8B43PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 1543PHRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 2 1043PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 2543PHRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 12X43PCRMA 3.50 (88.9) 9.40 (238.8) 1.8 (0.8) 12A63PHRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 2 423PCRMA 3.10 (78.7) 7.90 (200.7) 1.1 (0.5) 14S63PHRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 2043PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 16S63PHRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 2 6B23PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 7X23PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) Capacitor Cell 2 8B23PCRMA 3.50 (88.9) 9.40 (238.8) 1.8 (0.8) 2 1023PCRMA 3.50 (88.9) 9.40 (238.8) 1.3 (0.6) 12X23PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 2 1523PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 16S23PCRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 2 17X23PCRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 1X43PCRMA 2.10 (53.3) 5.00 (127.0) 0.7 (0.3) Height 2 243PCRMA 2.50 (63.5) 5.50 (139.7) 0.9 (0.4) 2 2X43PCRMA 2.50 (63.5) 5.50 (139.7) 0.9 (0.4) 343PCRMA 2.50 (63.5) 5.50 (139.7) 0.9 (0.4) 2 443PCRMA 2.50 (63.5) 6.50 (165.1) 0.9 (0.4) 543PCRMA 2.50 (63.5) 6.50 (165.1) 0.9 (0.4) 2 643PCRMA 3.10 (78.7) 7.90 (200.7) 1.1 (0.5) M12 2 7X43PCRMA 3.10 (78.7) 7.90 (200.7) 1.1 (0.5) 16+1 8B43PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 2 943PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 1043PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) Depth 2 12X43PCRMA 3.50 (88.9) 9.40 (238.8) 1.8 (0.8) 1543PCRMA 3.50 (88.9) 9.40 (238.8) 1.8 (0.8) 2 1843PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 2 2043PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 2543PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 2 3043PCRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 563PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 2 7X63PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 1063PCRMA 3.10 (78.7) 9.40 (238.8) 1.3 (0.6) 2 12X63PCRMA 3.50 (88.9) 9.40 (238.8) 1.8 (0.8) 2 1563PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 2063PCRMA 3.50 (88.9) 12.30 (312.4) 2.6 (1.2) 2 2563PCRMA 3.50 (88.9) 15.30 (388.6) 3.3 (1.5) 2 2 2 2 2

V3-T2-40 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

UNIPUMP Contents 2 Description Page Product Overview...... V3-T2-38 2 UNIPUMP Product Selection ...... V3-T2-42 2 Dimensions ...... V3-T2-43 UNIPAK...... V3-T2-44 2 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems ...... V3-T2-55 2 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems ...... V3-T2-58 2 AUTOVAR Filter—LV Automatic Harmonic Filter . . V3-T2-63 Transient-Free Static Switching Power Factor Correction Units...... V3-T2-67 2 Active-Harmonic Filter-Harmonic Correction Unit— NEMA 1 Enclosure ...... V3-T2-71 2 2 2 2 UNIPUMP Product Description Features, Benefits and Functions 2 Non-fused capacitors for outdoor irrigation and oil field Configuration ● Design: Self-healing ● Ceramic discharge 2 installations. ● Outer case: Heavy, No. 14 metallized high crystalline : Reduce residual gauge steel finished with polypropylene with ramp voltage to less than 50 volts 2 ● Designed expressly for durable powder coat finish. metallization film. Total within one minute of outdoor pumping Integral strap mounting losses less than 0.45 watt de-energization. Selected applications bracket with keyhole at top per kVAR. (Dielectric for 20-year nominal life. 2 ● Pole or wall mounting for pole or wall installation. losses less than 0.2 watt Exceeds NEC requirements ● Small, light-weight No knockouts per kVAR) ● Capacitor operating 2 enclosure for easy ● Ramp metallization: temperature: -40°F installation Capacitor Cells Provides thicker film at (–40°C) to +115°F (+46°C) 2 ● SO-WA type flexible cable ● Te rm i n a l s : Insulated higher current density ● Case: Weatherproof facilitates installation finger-safe terminals rated areas, allowing for reduced aluminum housing 2 internal losses, lower (4-conductor) for 3 kVAC withstand ● Warranty: The longest operating temperatures ● Gland-type weatherproof ● Dielectric fill: Dry-type in the industry—five full and longer life expectancy. 2 bushings cells use soft organic years of warranty on Also prevents chain ● polymer resin—Resinol capacitor cells Strong outer case reaction breakdown by 2 ● Eliminates potential for Application Description limiting propagation of Standards and Certifications corona/partial discharge/ film vaporization Outdoor irrigation and oil electrochemical oxidation ● UL and CSA listed 2 ● Pressure sensitive and gas field pumping. ● Excellent heat dissipation interrupter: Built-in, three- 2 ● Flash point: +444°F phase pop-up interrupter (+229°C) design. UL recognized. 2 ● Fire point: +840°F Removes capacitor from (+449°C) line before internal pressure can cause case 2 rupture. Bulged capacitor cell top provides easy 2 visual indication of interrupter operation 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-41 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Product Selection 2 UNIPUMP UNIPUMP Rated Case Cable Shipping Weight Catalog 2 kVAR Current Size Size in Lbs (kg) Number 2 240 Vac 2 4.8 AA 14.0 10.0 (4.5) 223JMR 2 2.5 6.0 AA 14.0 10.0 (4.5) 2X23JMR 3 7.2 AA 14.0 10.0 (4.5) 323JMR 2 4 9.6 AA 14.0 11.0 (5.0) 423JMR 2 5 12.0 AA 14.0 11.0 (5.0) 523JMR 6 14.4 BB 12.0 15.0 (6.8) 623JMR 2 7.5 18.0 BB 12.0 15.0 (6.8) 7X23JMR 480 Vac 2 2 2.4 AA 14.0 10.4 (4.7) 243JMR 2.5 3.0 AA 14.0 10.4 (4.7) 2X43JMR 2 3 3.6 AA 14.0 10.4 (4.7) 343JMR 2 4 4.8 AA 14.0 10.4 (4.7) 443JMR 5 6.0 AA 14.0 10.4 (4.7) 543JMR 2 6 7.2 AA 14.0 10.6 (4.8) 643JMR 7.5 9.0 AA 14.0 10.6 (4.8) 7X43JMR 2 10 12.0 AA 14.0 10.8 (4.9) 1043JMR 2 12.5 15.0 BB 12.0 15.0 (6.8) 12X43JMR 15 18.0 BB 12.0 15.0 (6.8) 1543JMR 2 17.5 21.0 BB 8.0 15.8 (7.2) 17X43JMR 20 24.0 BB 8.0 16.8 (7.6) 2043JMR 2 25 30.0 BB 8.0 16.8 (7.6) 2543JMR 600 Vac 2 5 4.9 AA 14.0 10.8 (4.9) 563JMR 2 7.5 7.4 AA 14.0 10.8 (4.9) 7X63JMR 10 9.8 AA 14.0 10.8 (4.9) 1063JMR 2 12.5 12.3 AA 12.0 15.0 (6.8) 12X63JMR 15 14.7 BB 12.0 15.8 (7.2) 1563JMR 2 17.5 17.2 BB 8.0 16.8 (7.6) 17X63JMR 2 20 19.6 BB 8.0 16.8 (7.6) 2063JMR 2 2 2 2 2 2 2 2 2

V3-T2-42 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Dimensions 2 Approximate Dimensions in Inches (mm) 2 UNIPUMP UNIPUMP Dimension Chart Size Code A B C D Ø 0.44 2 (11.2) AA 11.00 (279.4) 14.20 (360.7) 12.60 (320.0) 13.20 (335.3) Ø 0.88 1.84 (22.4) BB 14.00 (355.6) 17.10 (434.3) 15.50 (393.7) 16.10 (408.9) 2 (46.7) 2 1.75 (44.5) 2 2 2

D C A 2 2 2 2 1.45 (36.8) 2

0.50 0.75 Ø 0.44 (12.7) (19.1) (11.2) 2 1.50 (38.1) 2 5.15 (130.8) 0.07 2 (1.8) 1.55 (39.4) 2 2.56 (65.0) 1.98 2 (50.3) 2 2 B 2 2 2

1.75 2 (44.5) 5.00 (127.0) 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-43 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 UNIPAK Contents Description Page 2 Product Overview ...... V3-T2-38 UNIPUMP ...... V3-T2-41 2 UNIPAK Features, Benefits and Functions ...... V3-T2-45 2 Standards and Certifications ...... V3-T2-45 Product Selection ...... V3-T2-46 2 Wiring Diagram ...... V3-T2-52 Dimensions ...... V3-T2-53 2 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems...... V3-T2-55 2 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems...... V3-T2-58 2 AUTOVAR Filter—LV Automatic Harmonic Filter . . V3-T2-63 Transient-Free Static Switching Power Factor Correction Units...... V3-T2-67 2 Active-Harmonic Filter-Harmonic Correction Unit— 2 NEMA 1 Enclosure ...... V3-T2-71 2 UNIPAK 2 Product Description Application Description Designed for power factor 2 UNIPAK Filter— Harmonic Rated Capacitor Cells correction in plants Harmonic Filtering ● Standard voltage rated experiencing harmonics 2 Harmonic filter systems for capacitor cells designed for problems due to high low voltage, heavy-duty higher dielectric strength amounts of nonlinear loads. applications. and with added ability to 2 withstand stress caused ● Reduce harmonics and by dv/dt voltage transients correct power factor 2 caused by harmonics ● Tuned for maximum ● Better suited for harmonic efficiency in reducing 2 applications than higher harmonic currents voltage rated cells 2 associated with nonlinear load environments (such as UNIPAK with Harmonic Rated VFDs) Capacitor Cells 2 ● Two-enclosure design ● Standard capacitor isolates capacitors from systems using harmonic 2 high-temperature operating rated capacitor cells UNIPAK with Optional Air Filter reactors, and allows for ● For use in moderate flexible installation 2 harmonic environments ● Twenty-year life design where engineering 2 ● Five-year cell warranty/one- supervision allows in place year reactor warranty of harmonic filter designs 2 ● Three-phase cell capacitor ● Provides future conversion construction. Three-phase capability into a harmonic 2 interrupter system filter design due to facility growth or increased 2 nonlinear load levels 2 2 2 2 2

V3-T2-44 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Features, Benefits and Functions 2 ● Five-year warranty ● Cover: “L” shaped Capacitor cells ● Capacitor operating on capacitor cells gasketed cover with ● Te rm i n a l s : Insulated finger- temperature: -40°F (-40°C) 2 ● Designed for heavy-duty multiple fasteners provides safe terminals rated for 3 to +115°F (+46°C) applications front opening for ease of kVAC withstand ● Case: Weatherproof installation and service 2 ● Twenty-year life design ● Dielectric fill: Dry-type aluminum housing ● Ground terminal: ● ● Indoor/outdoor service cells use soft organic Warranty: The longest Furnished inside case polymer resin—Resinol in the industry—five full 2 ● Wall (up to 180 kVAR) ● and floor-mounted Power terminal lugs: ● Eliminates potential for years of warranty on units available Large size provided for corona/partial discharge/ capacitor cells 2 easy connection electrochemical ● Fuse protection standard ● Fusing: oxidation Reactors 2 ● Blown-fuse indicating ● ● ● Tuning: Tuned to 4.7 lights standard Size Code A1: Three Excellent heat midget-type fuses dissipation harmonic order 2 ● Quick lead-times ● with 100,000 ampere ● Flash point: +444°F Detuning: Reactor ● Harmonic filters available interrupting capacity (+229°C) designs can be detuned 2 ● ● upon request to 4.2nd to Slim profile allows reduced Size Code A2 and ● Fire point: +840°F protect capacitors against footprint, conserving larger: Three slotted- (+449°C) 2 valuable floor space blade type fuses with alternate harmonics ● ● New capacitor 200,000 ampere Design: Self-healing ● Construction: 100% configuration leads interrupting capacity; metallized high crystalline copper windings for cool 2 to cooler operating Fuses mounted on polypropylene with ramp operating temperatures; conditions, extending stand-off bushings or metallization film. Total designed operating 2 capacitor life fuse blocks; solderless losses less than 0.45 watt temperature rise less connectors for easy per kVAR. (Dielectric than 80ºC. Open frame 2 Configuration hookup of incoming line losses less than 0.2 watt construction with 220ºC per kVAR) ● Outer case: Heavy, No. 14 conductors insulation system 2 gauge steel finished with ● Fuse indicating lights: ● Ramp metallization: ● Thermal sensors: One durable powder coat finish. Red, neon blown-fuse Provides thicker film at per phase, self-resetting Wall mounting flanges indicating lights are higher current density thermistors provide 2 and floor mounting feet. protected by transparent areas, allowing for reduced reactor over-temperature Elimination of knockouts weatherproof guard internal losses, lower protection and indication 2 permits indoor/outdoor operating temperatures ● Reactor indicating light: ● Options: use. Manufactured to and longer life expectancy. Thermal overload indicating 2 NEMA requirements 1, ● No fuses Also prevents chain light activates when 3R and 12 ● Air filters for units reaction breakdown by reactor temperature 2 ● Elevated floor mounting with enclosure limiting propagation of reaches 180ºC film vaporization feet allow access for sizes C2, D1 and E1 ● Warranty: One-year ● 2 easy maintenance Pressure sensitive replacement of reactors Note: NEMA 12 enclosure interrupter: Built-in, three- standard for enclosure sizes phase pop-up interrupter Standards and Certifications 2 A1 to C1. design. UL recognized. ● UL and CSA listed Removes capacitor from 2 line before internal pressure can cause case 2 rupture. Bulged capacitor cell top provides easy visual indication of 2 interrupter operation ● Ceramic discharge 2 resistors: Reduce residual voltage to less than 50 volts 2 within one minute of de-energization. Selected 2 for 20-year nominal life. Exceeds NEC requirements 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-45 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Product Selection 2 UNIPAK Low Voltage Fixed Capacitor Banks

2 UNIPAK 240 Vac UNIPAK Rated Shipping Weight Part 2 kVAR Current Enclosure in Lbs (kg) Number 1 2.4 A1 18 (8) 123PMURF 2 1.5 3.6 A1 18 (8) 1X23PMURF 2 2 4.8 A1 19 (9) 223PMURF 2.5 6 A1 19 (9) 2X23PMURF 2 3 7.2 A1 19 (9) 323PMURF 4 9.6 A1 20 (9) 423PMURF 2 5 12 A2 29 (13) 523PMURF 2 6 14.4 A2 29 (13) 623PMURF 7.5 18 A2 30 (14) 7X23PMURF 2 8 19.2 A2 31 (14) 823PMURF 10 24 A2 31 (14) 1023PMURF 2 12.5 30 A2 32 (14) 12X23PMURF 15 36 A2 33 (15) 1523PMURF 2 17.5 42 B1 44 (20) 17X23PMURF 2 20 48 B1 45 (20) 2023PMURF 22.5 54 B1 46 (21) 22X23PMURF 2 25 60 B1 46 (21) 2523PMURF 30 72 B1 47 (21) 3023PMURF 2 32.5 78 B1 47 (22) 32X23PMURF 35 84 B1 48 (22) 3523PMURF 2 40 96 C1 64 (29) 4023PMURF 2 42.5 102 C1 65 (30) 42X23PMURF 45 108 C1 66 (30) 4523PMURF 2 50 120 C1 68 (31) 5023PMURF 60 144 C1 69 (31) 6023PMURF 2 70 168 C2 99 (45) 7023PMURF 2 75 180 C2 100 (46) 7523PMURF 80 192 C2 101 (46) 8023PMURF 2 90 216 C2 103 (47) 9023PMURF 100 240 C2 104 (47) 10023PMURF 2 120 288 D1 133 (60) 12023PMURF 140 336 D1 137 (62) 14023PMURF 2 150 360 D1 140 (64) 15023PMURF 2 160 384 E1 175 (80) 16023PMURF 180 432 E1 182 (83) 18023PMURF 2 200 480 E1 189 (86) 20023PMURF Notes 2 Multiply the 240 Vac kVAR rating by 0.75 to calculate the kVAR value at 208 Vac. Fused with blown-fuse indication available standard. Non-fused and no lights also available—please consult the factory. 2 Other ratings available, consult factory. For dimensional information, refer to Page V3-T2-53. 2 Part Numbers: PMURF—three fuses + three lights 2 PMURN—non-fused 2

V3-T2-46 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

UNIPAK 480 Vac UNIPAK 2 Rated Shipping Weight Part kVAR Enclosure Current in Lbs (kg) Number 2 1.5 A1 1.8 17 (8) 1X43PMURF 2 A1 2.4 18 (8) 243PMURF 2 2.5 A1 3 18 (8) 2X43PMURF 3 A1 3.6 19 (9) 343PMURF 2 4 A1 4.8 19 (9) 443PMURF 5 A1 6 19 (9) 543PMURF 2 6 A1 7.2 19 (9) 643PMURF 2 7.5 A1 9 20 (9) 7X43PMURF 8 A1 9.6 20 (9) 843PMURF 2 9 A1 10.8 20 (9) 943PMURF 10 A1 12 20 (9) 1043PMURF 2 12.5 A2 15 29 (13) 12X43PMURF 2 15 A2 18 29 (13) 1543PMURF 17.5 A2 21 30 (14) 17X43PMURF 2 20 A2 24 31 (14) 2043PMURF 22.5 B1 27 44 (20) 22X43PMURF 2 25 A2 30 32 (15) 2543PMURF 27.5 B1 33 44 (20) 27X43PMURF 2 30 B1 36 44 (20) 3043PMURF 2 32.5 B1 39 45 (20) 32X43PMURF 35 B1 42 45 (20) 3543PMURF 2 37.5 B1 45 46 (21) 37X43PMURF 40 B1 48 46 (21) 4043PMURF 2 42.5 B1 51 47 (21) 42X43PMURF 45 B1 54 47 (22) 4543PMURF 2 50 B1 60 48 (22) 5043PMURF 2 55 B1 66 48 (22) 5543PMURF 60 B1 72 48 (22) 6043PMURF 2 65 C1 78 64 (29) 6543PMURF 70 C1 84 65 (30) 7043PMURF 2 75 C1 90 65 (30) 7543PMURF 2 80 C1 96 66 (30) 8043PMURF 85 C1 102 68 (31) 8543PMURF 2 90 C1 108 68 (31) 9043PMURF 100 C1 120 68 (31) 10043PMURF 2 120 C1 144 68 (31) 12043PMURF 125 C2 150 99 (45) 12543PMURF 2 140 C2 168 100 (46) 14043PMURF 2 150 C2 180 101 (46) 15043PMURF 160 C2 192 103 (47) 16043PMURF 2 180 C2 216 104 (47) 18043PMURF

Notes 2 Fused with blown-fuse indication available standard. Non-fused and no lights also available—please consult the factory. 2 Other ratings available, consult factory. For dimensional information, refer to Page V3-T2-53. 2 Part Number PMURF—three fuses + three lights PMURN—non-fused 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-47 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 UNIPAK 480 Vac UNIPAK, continued Rated Shipping Weight Part 2 kVAR Enclosure Current in Lbs (kg) Number 200 D1 240 137 (62) 20043PMURF 2 225 D1 270 140 (64) 22543PMURF 250 E1 300 170 (77) 25043PMURF 2 300 E1 360 175 (80) 30043PMURF 350 E1 420 182 (83) 35043PMURF 2 400 E1 480 189 (86) 40043PMURF 2 Notes Fused with blown-fuse indication available standard. 2 Non-fused and no lights also available—please consult the factory. Other ratings available, consult factory. 2 For dimensional information, refer to Page V3-T2-53. Part Number PMURF—three fuses + three lights 2 PMURN—non-fused 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

V3-T2-48 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

UNIPAK 600 Vac UNIPAK 2 Rated Shipping Weight Part kVAR Enclosure Current in Lbs (kg) Number 2 5 A1 4.9 19 (9) 563PMURF 7.5 A1 7.4 19 (9) 7X63PMURF 2 10 A1 9.8 20 (9) 1063PMURF 12.5 A1 12.3 20 (9) 12X63PMURF 2 15 A2 14.7 29 (13) 1563PMURF 17.5 A2 17.2 29 (13) 17X63PMURF 2 20 A2 19.6 30 (14) 2063PMURF 2 22.5 B1 22.1 44 (20) 22X63PMURF 25 A2 24.5 31 (14) 2563PMURF 2 27.5 B1 27.0 44 (20) 27X63PMURF 30 B1 29.4 45 (20) 3063PMURF 2 32.5 B1 31.9 45 (20) 32X63PMURF 2 35 B1 34.3 46 (21) 3563PMURF 37.5 B1 36.8 46 (21) 37X63PMURF 2 40 B1 39.2 47 (21) 4063PMURF 42.5 B1 41.7 47 (22) 42X63PMURF 2 45 B1 44.1 48 (22) 4563PMURF 50 B1 49.0 48 (22) 5063PMURF 2 55 C1 53.9 64 (29) 5563PMURF 2 60 C1 58.8 64 (29) 6063PMURF 65 C1 63.7 65 (30) 6563PMURF 2 70 C1 68.6 65 (30) 7063PMURF 75 C1 73.5 66 (30) 7563PMURF 2 80 C1 78.4 68 (31) 8063PMURF 85 C1 83.3 68 (31) 8563PMURF 2 90 C1 88.2 68 (31) 9063PMURF 2 100 C1 98.0 68 (31) 10063PMURF 120 C2 117.6 99 (45) 12063PMURF 2 125 C2 122.5 100 (46) 12563PMURF 140 C2 137.2 101 (46) 14063PMURF 2 150 C2 147.0 103 (47) 15063PMURF 2 160 D1 156.8 135 (61) 16063PMURF 180 D1 176.4 137 (62) 18063PMURF 2 200 D1 196.0 140 (64) 20063PMURF 225 D1 220.5 143 (65) 22563PMURF 2 250 E1 245.0 170 (77) 25063PMURF 300 E1 294.0 175 (80) 30063PMURF 2 350 E1 343.0 182 (83) 35063PMURF 2 400 E1 392.0 189 (86) 40063PMURF

Notes 2 Fused with blown-fuse indication available standard. Non-fused and no lights also available—please consult the factory Other ratings available, consult factory 2 For dimensional information, refer to Page V3-T2-53. Part Numbers: 2 PMURF—three fuses + three lights PMURN—non-fused 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-49 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 UNIPAK—with Harmonic Cells 2 Harmonic Cells Low Voltage Fixed Capacitor Systems with Harmonic Cells Rated Case Shipping Weight Catalog 2 kVAR Current Size in Lbs (kg) Number 2 240V 15 36 B1 38.4 (17) 1523HURF 2 25 60 B1 38.4 (17) 2523HURF 30 72 C1 55.2 (25) 3023HURF 2 50 120 C1 57.6 (26) 5023HURF 60 144 C2 100.8 (46) 6023HURF 2 75 180 C2 104.4 (47) 7523HURF 2 100 240 D1 136.8 (62) 10023HURF 125 300 E1 189.6 (86) 12523HURF 2 480V 15 18 A2 25.2 (11) 1543HURF 2 25 30 B1 37.2 (17) 2543HURF 2 30 36 B1 38.4 (17) 3043HURF 50 60 B1 39.6 (18) 5043HURF 2 60 72 C1 52.8 (24) 6043HURF 75 90 C1 55.2 (25) 7543HURF 2 100 120 C1 57.6 (26) 10043HURF 125 150 C2 100.8 (46) 12543HURF 2 150 180 C2 104.4 (47) 15043HURF 2 200 240 D1 136.8 (62) 20043HURF 250 300 E1 186.0 (84) 25043HURF 2 300 360 E1 189.6 (86) 30043HURF 600V 2 15 14.7 B1 37.2 (17) 1563HURF 25 24.5 B1 38.4 (17) 2563HURF 2 30 29.4 B1 39.6 (18) 3063HURF 2 50 49 C1 55.2 (25) 5063HURF 60 58.8 C1 57.6 (26) 6063HURF 2 75 73.5 C2 100.8 (46) 7563HURF 100 98 C2 104.4 (47) 10063HURF 2 125 122.5 D1 136.8 (62) 12563HURF 2 150 147 D1 136.8 (62) 15063HURF 200 196 E1 186.0 (84) 20063HURF 2 250 245 E1 189.6 (86) 25063HURF Notes 2 Fused with blown-fuse indication standard. Other ratings available, consult factory. 2 2 2 2 2 2

V3-T2-50 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

UNIPAK Low Voltage Fixed Harmonic Filters 2 2 Harmonic Filters Fixed UNIPAK Harmonic Filters Reactor Reactor Combined Rated Case Shipping Weight Cabinet Shipping Weight Shipping Weight Catalog 2 kVAR Current Size in Lbs (kg) Case Size in Lbs (kg) in Lbs (kg) Number 240V 2 15 36 B1 48.4 (22.0) R 90.0 (40.9) 138.4 (62.8) 15232HMURF 2 25 60 B1 48.4 (22.0) R 105.0 (47.7) 153.4 (69.6) 25232HMURF 30 72 C1 65.2 (29.6) R 110.0 (49.9) 175.2 (79.5) 30232HMURF 2 50 120 C1 67.6 (30.7) R 130.0 (59.0) 197.6 (89.7) 50232HMURF 60 144 C2 110.8 (50.3) R 160.0 (72.6) 270.8 (122.9) 60232HMURF 2 75 180 C2 114.4 (51.9) R 185.0 (84.0) 299.4 (135.9) 75232HMURF 100 240 D1 146.8 (66.6) R 240.0 (109.0) 386.8 (175.6) 100232HMURF 2 125 300 E1 199.6 (90.6) S 280.0 (127.1) 479.6 (217.7) 125232HMURF 2 150 360 E1 220.0 (99.9) S 280.0 (127.1) 500.0 (227.0) 150232HMURF 480V 2 15 18 A2 35.2 (16.0) R 90.0 (40.9) 125.2 (56.8) 15432HMURF 25 30 B1 47.2 (21.4) R 105.0 (47.7) 152.2 (69.1) 25432HMURF 2 30 36 B1 48.4 (22.0) R 110.0 (49.9) 158.4 (71.9) 30432HMURF 50 60 B1 49.6 (22.5) R 130.0 (59.0) 179.6 (81.5) 50432HMURF 2 60 72 C1 62.8 (28.5) R 160.0 (72.6) 222.8 (101.2) 60432HMURF 2 75 90 C1 65.2 (29.6) R 185.0 (84.0) 250.2 (113.6) 75432HMURF 100 120 C1 67.6 (30.7) R 240.0 (109.0) 307.6 (139.7) 100432HMURF 2 125 150 C2 110.8 (50.3) R 280.0 (127.1) 390.8 (177.4) 125432HMURF 150 180 C2 114.4 (51.9) S 280.0 (127.1) 394.4 (179.1) 150432HMURF 2 200 240 D1 146.8 (66.6) S 330.0 (149.8) 476.8 (216.5) 200432HMURF 2 250 300 E1 196.0 (89.0) T 570.0 (258.8) 766.0 (347.8) 250432HMURF 300 360 E1 199.6 (90.6) T 575.0 (261.1) 774.6 (351.7) 300432HMURF 2 600V 15 14.7 B1 47.2 (21.4) R 90.0 (40.9) 137.2 (62.3) 15632HMURF 2 25 24.5 B1 48.4 (22.0) R 90.0 (47.7) 153.4 (69.6) 25632HMURF 30 29.4 B1 49.6 (22.5) R 105.0 (49.9) 159.6 (72.5) 30632HMURF 2 50 49 C1 65.2 (29.6) R 110.0 (59.0) 195.2 (88.6) 50632HMURF 2 60 58.8 C1 67.6 (30.7) R 130.0 (72.6) 227.6 (103.3) 60632HMURF 75 73.5 C2 110.8 (50.3) R 160.0 (84.0) 295.8 (134.3) 75632HMURF 2 100 98 C2 114.4 (51.9) R 185.0 (109.0) 354.4 (160.9) 100632HMURF 125 122.5 D1 146.8 (66.6) S 240.0 (127.1) 426.8 (193.8) 125632HMURF 2 150 147 D1 146.8 (66.6) S 280.0 (127.1) 426.8 (193.8) 150632HMURF 200 196 E1 196.0 (89.0) T 330.0 (149.8) 526.0 (238.8) 200632HMURF 2 250 245 E1 199.6 (90.6) T 570.0 (258.8) 769.6 (349.4) 250632HMURF 2 Notes Other ratings available, consult factory. 2 Fused with blown-fuse indication standard. 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-51 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Wiring Diagram Filter Schematic with Wiring Interconnects 2 Power Lines from Disconnect 2 Lugs 2 2 Fuses 2 Reactor 2 2 Lugs Interconnects (Provided by Customer) a 2 Lugs 2 Capacitor Bank

2 Note 1 2 Refer to NEC. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

V3-T2-52 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Dimensions 2 Approximate Dimensions in Inches (mm) Reactor Cabinet Reactor Cabinet 2 Case Size Height Width Depth 2 R 24.75 (628.7) 20.00 (508.0) 18.13 (460.5) S 25.00 (635.0) 24.25 (616.0) 20.25 (514.4) 2 T 31.00 (787.4) 25.00 (635.0) 32.75 (831.9) 2 2 2 Low Voltage Fixed Capacitor Banks and Fixed Harmonic Filters Case A1, A2 Case B1 2 2 2 2 2 2 2 2 2 2 2 2 2 2

UNIPAK Enclosures 2 Case Size A B D E F H L X1 X2 X3 Y Z 2 A1 5.30 (134.6) 8.50 (215.9) 3.50 (88.9) 3.80 (96.5) 10.60 (269.2) 17.30 (439.4) 6.80 (172.7) 2.00 (50.8) N/A N/A 7.70 (195.6) 7.20 (182.9) A2 6.00 (152.4) 8.50 (215.9) 5.60 (142.2) 4.50 (114.3) 13.30 (337.8) 22.30 (566.4) 6.80 (172.7) 2.30 (58.4) N/A N/A 7.70 (195.6) 7.20 (182.9) 2 B1 11.10 (281.9) 10.10 (256.5) 5.80 (147.3) 9.60 (243.8) 15.70 (398.8) 25.30 (642.6) 8.50 (215.9) 4.10 (104.1) 4.50 (114.3) N/A 9.30 (236.2) 8.80 (223.5) 2 Legend: A = Total depth B = Total width 2 D = Height of removable front cover E = Depth of feet 2 F = Height of middle mounting hole in wall bracket H = Total height 2 L = Width without feet and brackets X = Depth between front and rear mounting holes in inches 2 Y = Width between floor mounting holes Z = Width between wall bracket mounting holes 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-53 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Approximate Dimensions in Inches (mm) Case C1, C2 Case D1, E1 2 2 2 2 2 2 2 2 2 2 2 2 2 2

2 UNIPAK Enclosures Case 2 SizeABDEF HL X1X2X3YZ C1 10.60 (269.2) 12.10 (307.3) 7.10 (180.3) 9.10 (231.1) 16.20 (411.5) 26.30 (668.0) 10.40 (264.2) 3.40 (86.4) 1.10 (27.9) 3.60 (91.4) 11.30 (287.0) 10.70 (271.8) 2 C2 12.00 (304.8) 19.30 (490.2) 16.90 (429.3) 9.50 (241.3) 16.30 (414.0) 36.00 (914.4) 17.70 (449.6) 3.00 (76.2) 1.50 (38.1) 3.80 (96.5) 18.30 (464.8) 18.00 (457.2) 2 D1 16.80 (426.7) 19.30 (490.2) 16.90 (429.3) 14.60 (370.8) N/A 36.00 (914.4) 17.70 (449.6) 5.10 (129.5) 2.40 (61.0) 5.00 (127.0) 18.30 (464.8) N/A E1 22.30 (566.4) 24.40 (619.8) 16.80 (426.7) 19.50 (495.3) N/A 36.00 (914.4) 22.70 (576.6) 6.50 (165.1) 4.40 (111.8) 5.00 (127.0) 22.40 (569.0) N/A

2 Legend: A = Total depth 2 B = Total width D = Height of removable front cover 2 E = Depth of feet F = Height of middle mounting hole in wall bracket 2 H = Total height L = Width without feet and brackets X = Depth between front and rear mounting holes in inches 2 Y = Width between floor mounting holes 2 Z = Width between wall bracket mounting holes 2 2 2 2 2

V3-T2-54 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

AUTOVAR 300 Contents 2 Description Page Product Overview...... V3-T2-38 2 UNIPUMP...... V3-T2-41 UNIPAK...... V3-T2-44 2 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems 2 Product Selection ...... V3-T2-56 Options ...... V3-T2-56 2 Dimensions ...... V3-T2-57 AUTOVAR 600 Automatic Power Factor Correction 2 Capacitor Systems ...... V3-T2-58 AUTOVAR Filter—LV Automatic Harmonic Filter . . V3-T2-63 2 Transient-Free Static Switching Power Factor Correction Units...... V3-T2-67 Active-Harmonic Filter-Harmonic Correction Unit— 2 NEMA 1 Enclosure ...... V3-T2-71 2 2 2 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems Product Description Features 2 Automatically switched power factor correction Configuration Controller Contactor 2 systems for low voltage ● Cabinet: Wall mounting 12 ● Digital display of power ● Fully rated for capacitor applications. gauge steel with ANSI 61 factor and number of switching up to 60 kVAR 2 gray, NEMA 1 (gasketed) energized banks at 600V ● Wallmount design is ● Power line interconnect: ● Visual indication of ● Integral pre-charge/pre- ideal for minimum space 2 Rugged, power distribution insufficient kVAR to reach insertion module standard. requirements block connection target power factor The contactor reduces ● Programmable to 2 ● Fusing: 200,000 ampere ● LCD backlight display damaging switching automatically add/subtract interrupting capacity ● transients. This provides capacitor banks to maintain Capacitors disabled in provided on all three phases safety and durability for 2 preset target power factor steps within 35 ms of main of each bank. Blade-type the system: ● power interruption Heavy-duty, three-phase fuses mounted on insulator ● Lessens the chance 2 capacitor construction ● Harmonic measurement stand-offs with blown-fuse up to 19 harmonic and of disrupting sensitive ● Five-year warranty of cells indicating lights alarm (THDV) electronic equipment 2 ● Blown-fuse lights: Blown- ● Reduced inrush current Application Description ● Automatic detection and fuse indicating lights for extends the life of the Service entrance power correction of CT and phase 2 each phase and stage polarity capacitor cells factor correction installations located on the door requiring precise ● Automatic detection of 2 ● Additional Features maintenance of target Door interlock: Door connected steps interlock automatically ● Optional molded case power factor in a very ● Maximum 14 output steps circuit breaker rated 2 small footprint. disengages capacitors. Power continues to be ● Provides protection 65 kAIC at 480V and 600V provided to the unit until against overvoltage, ● Personnel ground fault 2 the disconnect is open overtemperature and interruption provides ● Exhaust fans: Provide harmonic overload events protection in case of 2 ventilation. Dust filtering ● Advanced control features accidental contact with included available control power and ground 2 ● Optional communications ● NEMA 3R weatherproofing capability (C option controller) Standards and Certifications 2 ● Standard metering capability ● ● Voltage UL/CSA listed and recognized 2 ● Current (sensed phase only) 2 ● Frequency ● Active power (kW) 2 ● Reactive power (kVAR) ● Apparent power (kVA) 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-55 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Product Selection

2 1 Wallmounted Wallmounted Switched Capacitor Banks—Low Voltage Applications Switched Capacitor Step x Rated Current Case Shipping Weight Catalog Bank 2 2 kVAR kVAR Amperes Size in Lbs (kg) Number 2 240 Volt 25 5 x 5 60 J 217 (98.5) 25MCSR2313 2 50 5 x 10 120 J 255 (115.8) 50MCSR2313 75 5 x 15 180 J 260 (118.0) 75MCSR2313 2 100 5 x 20 240 J 270 (122.6) 100MCSR231 2 125 5 x 25 300 J 292 (132.6) 125MCSR231 150 5 x 30 361 J 314 (142.6) 150MCSR231 2 480 Volt 50 5 x 10 60 J 200 (90.8) 50MCSR4313 2 75 5 x 15 90 J 210 (95.3) 75MCSR4313 100 5 x 20 120 J 210 (95.3) 100MCSR4313 2 125 5 x 25 150 J 240 (109.0) 125MCSR4313 2 150 5 x 30 180 J 240 (109.0) 150MCSR4313 175 5 x 35 210 J 260 (118.0) 175MCSR431 2 200 5 x 40 241 J 270 (122.6) 200MCSR431 225 5 x 45 270 J 290 (131.7) 225MCSR431 2 250 5 x 50 300 J 292 (132.6) 250MCSR431 2 300 5 x 60 361 J 310 (140.7) 300MCSR431 600 Volt 2 50 5 x 10 48 J 200 (90.8) 50MCSR6313 75 5 x 15 72 J 210 (95.3) 75MCSR6313 2 100 5 x 20 96 J 210 (95.3) 100MCSR6313 125 5 x 25 120 J 240 (109.0) 125MCSR6313 2 150 5 x 30 144 J 240 (109.0) 150MCSR6313 2 175 5 x 35 168 J 260 (118.0) 175MCSR631 200 5 x 40 192 J 270 (122.6) 200MCSR631 2 225 5 x 45 216 J 290 (131.7) 225MCSR631 250 5 x 50 240 J 292 (132.6) 250MCSR631 2 300 5 x 60 288 J 310 (140.7) 300MCSD631 2 Options 2 Description Option Code 2 Current transformer—multi-tap, split core current transformer (3000:5A) 3 TX2 Hands-off auto switch—provides manual control to connect or disconnect capacitor stages regardless of controller output H 2 Remote alarm relay—relay for a remote alarm to indicate inability to reach target power factor A 2 Molded case circuit breaker (65 kAIC at 480V) M Weatherproofing (NEMA 3R) W 2 Communicating controller C

Notes 2 1 Other ratings available, please consult factory. 2 For dimensional information, refer to Page V3-T2-57. 2 3 A current transformer with a 5 ampere secondary is required to operate an automatic capacitor bank. Rating based on service entrance ampacity. For other ratios, please consult factory. 2 2

V3-T2-56 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Dimensions 2 Approximate Dimensions in Inches (mm)

Enclosure J 2 Front View Side View 2 On/Off 0.63 Switch (16.0) 2

Power 2 Factor Controller 2

Keylock Handle 2

A 2 Blown 2 Fuse Lights 2

29.88 2 (759.0) 36.00 2 (914.4) 0.63 (16.0) 2 B 2 Enclosure J Description Height A Depth B 2 Without MCCB 36.00 (914.4) 14.00 (355.6) 2 With MCCB 60.00 (1524.0) 14.00 (355.6) 2 2 2 2 2 2 2 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-57 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 AUTOVAR 600 Contents Description Page 2 Product Overview ...... V3-T2-38 UNIPUMP ...... V3-T2-41 2 UNIPAK ...... V3-T2-44 AUTOVAR 300 Automatic Power Factor Correction 2 Capacitor Systems...... V3-T2-55 AUTOVAR 600 Automatic Power Factor Correction 2 Capacitor Systems Standards and Certifications ...... V3-T2-59 2 Product Selection ...... V3-T2-60 Options ...... V3-T2-61 2 Dimensions ...... V3-T2-62 AUTOVAR Filter—LV Automatic Harmonic Filter . . V3-T2-63 Transient-Free Static Switching Power Factor 2 Correction Units...... V3-T2-67 Active-Harmonic Filter-Harmonic Correction Unit— 2 NEMA 1 Enclosure ...... V3-T2-71 2 2 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems 2 Product Description Features Programmable to ● Heavy-duty, three-phase ● Fusing: UL recognized, ● Exhaust fans: Two fans 2 automatically add/subtract capacitor construction 200,000 ampere per cabinet provide thermal capacitor banks to maintain ● Five-year warranty of cells interrupting capacity protection. Dust filtering 2 preset target power factor. provided on all three provided Configuration phases of each bank. ● Ease of expansion: Application Description Blade-type fuses mounted 2 ● Cabinet: 12 gauge steel Capacitor stage nests are Service entrance power with ANSI 61 gray, powder on insulator stand-offs self-contained and can be 2 factor correction installations coat finish. Lift bolts ● Blown-fuse lights: Blown- added in the field. Two requiring precise standard, NEMA 1 fuse indicating lights are on bolts mount the nest in the maintenance of target ● the door located close to field. Control wire plugs 2 power factor. Power line interconnect: Rugged, copper bus bar individual fuses to facilitate connect to factory connection with access tracing of cleared fuses standard wire harness on 2 provided for top or bottom ● Push-to-test: Allows the left side of the cabinet entry. Bus bars are braced testing of door-mounted ● Ease of replacement: 2 for 65 kAIC at 480V. All blown fuse indicating lights Cells can be easily internal power wiring ● AutoLocate: When door is individually replaced by 2 connections from bus are open and bus energized, removing the mounting laid out on a most direct fuse circuit automatically bolt and lifting out of the basis with minimum checks for cleared fuses. nest without removal of 2 bends for ease of If a fuse has cleared, the any other components troubleshooting. Clear light at the fuse comes on 2 barrier limiting access to for easy troubleshooting live parts included standard ● Door interlock: Door 2 ● Modular tray design: interlock automatically Capacitor banks arranged turns off control circuit 2 in modular trays with when engaged. Power capacitors, fuses, blown- continues to be provided 2 fuse indicating lights, and to the unit until disconnect contactors grouped in a is open logical, easily understood 2 layout. This permits easy access, quick identification 2 of operating problems and ease of expandability 2 2 2

V3-T2-58 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Controller Contactor 2 ● Digital display of power ● Fully rated for capacitor factor and number of switching up to 60 kVAR energized banks at 600V 2 ● Visual indication of ● Integral pre-charge/pre- insufficient kVAR to reach insertion module standard. 2 target power factor The contactor reduces ● LCD backlight display damaging switching 2 transients. This provides ● Capacitors disabled in steps within 35 ms of main safety and durability for 2 power interruption the system: ● Lessens the chance of ● Harmonic measurement 2 up to 19 harmonic and disrupting sensitive alarm (THDV) electronic equipment 2 ● Reduced inrush current ● Automatic detection and correction of CT and phase extends the life of the capacitor cells 2 polarity Modular Step Nest Assembly ● Automatic detection of Additional Features 2 connected steps ● Optional molded case AUTOVAR 600—Interior View ● Maximum 14 output steps circuit breaker, rated 65 2 ● Provides protection kAIC at 48V and 600V against overvoltage, ● Personnel ground fault 2 overtemperature and interruption provides harmonic overload events protection in case of 2 ● Advanced control features accidental contact with available control power and ground ● 2 Optional communications ● Control wiring—standard capability (C option controller) NEC color-coded modular ● Standard metering capability bundles with quick 2 ● Voltage disconnect feature for ease of troubleshooting or ease 2 ● Current (sensed phase of expendability only) ● Optional digital metering ● Frequency 2 ● Active power (kW) 2 ● Reactive power (kVAR) ● Apparent power (kVA) Bottom Entry Location 2 Factory Pre-Wired for Future Expansion 2 2 Standards and Certifications ● UL/CSA listed 2 and recognized 2 2 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-59 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Product Selection 2 Floor-Mounted Switched Capacitor Banks—Low Voltage Applications

2 Floor-Mounted 240 Vac Switched Capacitor Step x Rated Current Enclosure Shipping Weight Catalog Bank 2 kVAR kVAR Amperes Size in Lbs (kg) Number 75 3 x 25 180 L 644 (292.4) 75TPCSR231 2 100 4 x 25 214 L 692 (314.2) 100TPCSR231 2 125 5 x 25 300 L 740 (336.0) 125TPCSR231 150 6 x 25 316 L 788 (357.8) 150TPCSR231 2 200 8 x 25 481 L 884 (401.3) 200TPCSR231 250 10 x 25 600 L 944 (428.6) 250TPCSR231 2 300 12 x 25 720 L 1022 (464.0) 300TPCSR231 2 350 7 x 50 844 KK 1616 (734.0) 350TPCSR231 400 8 x 50 965 KK 1704 (774.0) 400TPCSR231 2 2 480 Vac Step x Rated Current Enclosure Shipping Weight Catalog 2 kVAR kVAR Amperes Size in Lbs (kg) Number 150 3 x 50 180 L 632 (287.0) 150TPCSR431 2 200 4 x 50 240 L 676 (306.9) 200TPCSR431 250 5 x 50 300 L 720 (326.9) 250TPCSR431 2 300 6 x 50 360 L 764 (346.9) 300TPCSR431 2 350 7 x 50 420 L 808 (366.8) 350TPCSR431 400 8 x 50 480 L 852 (386.8) 400TPCSR431 2 450 9 x 50 540 L 896 (406.8) 450TPCSR431 500 10 x 50 600 L 944 (428.6) 500TPCSR431 2 550 11 x 50 660 L 984 (446.7) 550TPCSR431 600 12 x 50 720 L 1022 (464.0) 600TPCSR431 2 660 11 x 60 792 L 1010 (458.5) 660TPCSR431 2 700 7 x 100 840 L 1616 (734.0) 700TPCSR431 720 12 x 60 864 L 1050 (476.7) 720TPCSR431 2 800 8 x 100 960 KK 1704 (774.0) 800TPCSR431 840 14 x 60 1008 L 1690 (767.7) 840TPCSR431 2 900 9 x 100 1080 KK 1792 (814.0) 900TPCSR431 1000 10 x 100 1200 KK 1888 (857.0) 1000TPCSR431 2 1100 11 x 100 1320 KK 1966 (893.0) 1100TPCSR431 2 1200 12 x 100 1440 KK 2044 (928.0) 1200TPCSR431 Notes 2 Other ratings and step configurations available, please consult factory. For dimensional information, refer to Page V3-T2-62. 2 2 2 2 2 2

V3-T2-60 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Floor-Mounted 600 Vac 2 Capacitor Bank Step x Rated Current Enclosure Shipping Weight Catalog 1 kVAR kVAR Amperes Size in Lbs (kg) Number 2 150 3 x 50 144 L 632 (287.0) 150TPCSR631 200 4 x 50 192 L 676 (306.9) 200TPCSR631 2 250 5 x 50 240 L 720 (326.9) 250TPCSR631 300 6 x 50 288 L 764 (346.9) 300TPCSR631 2 350 7 x 50 336 L 808 (366.8) 350TPCSR631 400 8 x 50 384 L 852 (386.8) 400TPCSR631 2 450 9 x 50 432 L 896 (406.8) 450TPCSR631 2 500 10 x 50 480 L 944 (428.6) 500TPCSR631 550 11 x 60 528 L 984 (446.7) 550TPCSR631 2 600 12 x 50 576 L 1022 (464.0) 600TPCSR631 660 11 x 60 634 L 1010 (458.5) 660TPCSR631 2 700 7 x 100 672 L 1616 (734.0) 700TPCSR631 2 720 12 x 60 692 L 1050 (476.7) 720TPCSR631 800 8 x 100 768 KK 1704 (774.0) 800TPCSR631 2 840 14 x 60 1008 L 1690 (767.7) 840TPCSR631 900 9 x 100 864 KK 1792 (814.0) 900TPCSR631 2 1000 10 x 100 960 KK 1888 (857.0) 1000TPCSR631 1100 11 x 100 1056 KK 1966 (893.0) 1100TPCSR631 2 1200 12 x 100 1152 KK 2044 (928.0) 1200TPCSR631 2 2 Options

Description Option Code 2 Current transformer—multi-tap, split core current transformer (3000:5A) 2 TX2 2 Hands-off auto switch—provides manual control to connect or disconnect capacitor stages regardless of controller output H Remote alarm relay—relay for a remote alarm to indicate inability to reach target power factor A 2 Molded case circuit breaker (65 kAIC at 480V) M Weatherproofing (NEMA 3R) W 2 Communicating controller C 2 IQ 250 solid-state meter 3 Q

Notes 2 1 Other ratings and step sizes available, please consult factory. 2 A current transformer with a 5 ampere secondary is required to operate an automatic capacitor bank. Rating based on service entrance ampacity. 2 For other ratios, please consult factory. 3 Not available with weatherproofing option. 2 For dimensional information, refer to Page V3-T2-62. 2 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-61 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Dimensions Approximate Dimensions in Inches (mm) 2 Enclosure L Front View 2 (Note: Fans are 38.50 (Note: Fans are 26.25 Vertical Toward (977.9) (666.8) 2 Back of Enclosure) Side by Side) Fans Fans 2 1 Ground Lug 2 2

DANGER HIGH VOLTAGE CAUTION 2 PHASE A PHASE B PHASE C DISCONNECT BEFORE SERVICING

2 3 71.25 11.75 (1809.8) 75.00 (298.5) (1905.0) 2

46.00 2 (1168.4) 2 2 3.00 2 (76.2)

2 6.00 Filter Tray (152.4) Legend 13.00 (330.2) 2 1. Controller 0.438 ø Mounting Holes 2. On/Off Switch 25.00 2 per Channel 3. Blown Fuse Indicator Lights (635.0) 2 2 Enclosure KK Front and Side Views Fans 78.25 Fans 26.25 2 (1987.6) (666.8)

(Note: Fans are (Note: Fans are 2 Vertical Towards Side by Side) 1 Back of Enclosure) Ground Lug 2 2

DANGER

PHASE A PHASE B PHASE C 2 HIGH VOLTAGE CAUTION DISCONNECT BEFORE SERVICING 3 71.25 (1809.8) 2 11.75 75.00 (298.5) (1905.0) 2 46.00 2 (1168.4) 2

3.00 2 0.438 ø (76.2) Mounting Holes 2 2 per Channel 13.00 2 Legend Filter Tray Filter Tray (330.2) 1. Controller 6.00 (152.4) 2. On/Off Switch 25.00 2 3. Blown Fuse Indicating Light (635.0) 2

V3-T2-62 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

AUTOVAR Filter Contents 2 Description Page Product Overview...... V3-T2-38 2 UNIPUMP...... V3-T2-41 UNIPAK...... V3-T2-44 2 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems ...... V3-T2-55 2 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems ...... V3-T2-58 2 AUTOVAR Filter—LV Automatic Harmonic Filter Standards and Certifications ...... V3-T2-64 2 Product Selection ...... V3-T2-65 Options ...... V3-T2-65 2 Dimensions ...... V3-T2-66 Transient-Free Static Switching Power Factor Correction Units...... V3-T2-67 2 Active-Harmonic Filter-Harmonic Correction Unit— NEMA 1 Enclosure ...... V3-T2-71 2 2 2 AUTOVAR Filter—LV Automatic Harmonic Filter Product Description Features 2 Automatically switched ● Efficient modular design ● Power line interconnect: ● Push-to-test: Allows harmonic filter/ power for short lead-times, ease Rugged, copper bus bar testing of door-mounted 2 factor corrections systems. of maintenance and ease connection with access blown fuse indicating lights. of future expansion provided for top or bottom ● AutoLocate: When door is ● Programmable to 2 ● entry. Bus bars are braced automatically add/subtract Heavy-duty, three-phase open and bus energized, capacitor construction with for 65 kAIC at 480V. All fuse circuit automatically 2 filter banks to maintain internal power wiring preset target power factor reliable, threaded terminal checks for cleared fuses. connections connections from bus are If a fuse has cleared, the ● Filter steps tuned for laid out on a most direct 2 ● Cool operating, 100% light at the fuse comes on maximum efficiency in basis with minimum bends for easy troubleshooting reducing harmonic copper wound, thermal for ease of troubleshooting. ● 2 currents in three-phase protected reactors are Door interlock: Door sized up to 150% of rated Clear barrier limiting interlock automatically environments with heavy access to live parts included 2 nonlinear loads capacitor current turns off control circuit standard when engaged. Power Application Description Configuration ● Modular tray design: continues to be provided 2 Capacitor banks arranged Service entrance power ● Operation: AUTOVAR to the unit until disconnect harmonic filters are in modular trays with is open factor correction installations capacitors, fuses, blown- 2 requiring precise maintenance designed to be sized the ● Exhaust fans: Two same as any power factor fuse indicating lights, and fans per cabinet provide of target power factor in contactors grouped in a 2 three-phase, nonlinear, high correction unit. In most low thermal protection. voltage applications where logical, easily understood Dust filtering provided harmonic environments. layout. This permits easy harmonics are generated ● 2 access, quick identification Ease of expansion: by nonlinear loads, Capacitor stage nests are no harmonic audit is of operating problems and 2 ease of expandability self-contained and can be necessary to design the added in the field. Control ● AUTOVAR filter because Fusing: UL recognized, wire plugs connect to 2 it is already designed 200,000 ampere factory standard wire for typical harmonic interrupting capacity harness on the left side 2 spectrums at the kVAR provided on all three of the cabinet size specified phases of each bank. ● Ease of replacement: ● Cabinet: 12 gauge steel Blade-type fuses mounted 2 on insulator stand-offs Cells can be easily with ANSI 61 gray, powder individually replaced by ● coat finish. Lift bolts Blown-fuse lights: Blown- removing the mounting 2 standard, NEMA 1 fuse indicating lights are on bolt and lifting out of the the door located close to nest without removal of 2 individual fuses to facilitate any other components tracing of cleared fuses 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-63 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Controller Reactors Additional Features Standards and Certifications ● Digital display of power ● Tuning: Reactors tuned ● Optional molded case ● UL/CSA listed factor and number of to the 4.7th harmonic circuit breaker rated and recognized 2 energized banks order (nominal 5th). 65 kAIC at 480V and 600V ● Visual indication of This provides maximum ● Personnel ground fault 2 insufficient kVAR to reach effectiveness in reducing interruption provides target power factor harmonic currents in protection in case of three-phase systems 2 ● LCD backlight display accidental contact with with harmonics caused ● control power and ground Capacitors disabled in by six-pulse devices 2 steps within 35 ms of main ● Control wiring—standard ● power interruption Detuning: Reactor NEC color-coded modular designs can be detuned bundles with quick 2 ● Harmonic measurement upon request to 4.2nd to disconnect feature for up to 19 harmonic and protect capacitors against alarm (THDV) ease of troubleshooting 2 alternate harmonics or ease of expendability ● Automatic detection and ● Windings: 100% copper 2 correction of CT and phase windings for minimal polarity temperature rise under 2 ● Automatic detection of load connected steps ● Thermal overload 2 ● Maximum 14 output steps protection: Each reactor ● Provides protection includes three normally 2 against overvoltage, closed, auto reset overtemperature and thermostats that 2 harmonic overload events open at 180°C. When ● Advanced control features thermostats engage, available the contactor opens ● 2 ● Optional communications Insulation: 220°C capability (C option controller) insulation system ● 2 ● Standard metering capability Warranty: One-year replacement of reactors 2 ● Voltage ● Current (sensed phase 2 only) ● Frequency 2 ● Active power (kW) ● Reactive power (kVAR) 2 ● Apparent power (kVA) AUTOVAR Filter—Reactor Cabinet Contactor 2 ● Fully rated for capacitor switching up to 60 kVAR 2 at 600V ● Integral pre-charge/pre- 2 insertion module standard. The contactor reduces 2 damaging switching transients. This provides 2 safety and durability for the system: ● Lessens the chance of 2 disrupting sensitive electronic equipment 2 ● Reduced inrush current extends the life of the 2 capacitor cells 2 2 2 2

V3-T2-64 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Product Selection 2 Low Voltage Switched Harmonic Filters 2

Floor-Mounted Floor-Mounted Switched Harmonic Filters—Low Voltage 2 Switched Harmonic Step x Rated Current Enclosure Shipping Weight Catalog Filter 2 34 kVAR kVAR Amperes Size in Lbs (kg) Number 2 480 Vac 200 4 x 50 240 L 1438 (652.9) 200THFSR431 2 250 1 5 x 50 300 L 1634 (741.8) 250THFSR431 2 300 6 x 50 360 KK or L + L 1830 (830.8) 300THFSR432 350 7 x 50 420 KK or L + L 2026 (919.8) 350THFSR432 2 400 8 x 50 480 KK or L + L 2222 (1008.8) 400THFSR432 450 9 x 50 540 KK or L + L 2371 (1076.4) 450THFSR432 2 500 10 x 50 600 KK or L + L 2525 (1146.4) 500THFSR432 1 2 550 11 x 50 660 KK or L + L 2750 (1248.5) 550THFSR432 600 1 12 x 50 720 KK or L + L 2830 (1284.8) 600THFSR432 2 600 Vac 300 6 x 50 288 KK or L + L 1830 (830.8) 300THFSR632 2 350 7 x 50 336 KK or L + L 2026 (919.8) 350THFSR632 400 8 x 50 384 KK or L + L 2222 (1008.8) 400THFSR632 2 450 9 x 50 432 KK or L + L 2371 (1076.4) 450THFSR632 2 500 10 x 50 480 KK or L + L 2525 (1146.4) 500THFSR632 550 1 11 x 50 528 KK or L + L 2750 (1248.5) 550THFSR632 2 600 1 12 x 50 576 KK or L + L 2830 (1284.8) 600THFSR632 2

Options 2

Description Option Code 2 Current transformer—multi-tap, split core current transformer 5 TX2 Hands-off auto switch—provides manual control to connect or disconnect capacitor stages regardless of controller output H 2 Remote alarm relay—relay for a remote alarm to indicate inability to reach target power factor A 2 Molded case circuit breaker (65 kAIC at 480V) M Weatherproofing (NEMA 3R) W 2 Communicating controller C IQ 250 solid-state meter 6 Q 2

Notes 2 1 Enclosures for 550 and 600 kVAR at 480 and 600V will be one double-door section wide if circuit breakers are required (enclosure size KK). Enclosure for 250 kVAR at 480V will be one double-door section wide if a circuit breaker is required. 2 Other ratings available, please consult factory. 2 3 L + L under enclosure size denotes two size L enclosures—one for the capacitors, one for the reactor case. 4 For KK enclosure design, change the last digit of the catalog number to 1. For example, 500THFSR431. 2 5 A current transformer with a 5 ampere secondary is required to operate an automatic capacitor bank. Rating based on service entrance ampacity. For other ratios, please consult factory. 6 Not available with weatherproofing option. 2 For dimensional information, refer to Page V3-T2-66. 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-65 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Dimensions Approximate Dimensions in Inches (mm) 2 Enclosures L + L Front and Side Views 2 (Note: Fans are 89.00 26.25 Vertical Toward (2260.6) (Note: Fans are (666.8) 2 Back of Enclosure) 38.50 38.50 Side by Side) (977.9) (977.9) 2 Fans Fans (Note: Fans are (Note: Fans are Ground 2 Side by Side) Vertical Towards Lug 1 Back of Enclosure) Fans 2 2 Fans DANGER DANGER HIGH VOLTAGE HIGH VOLTAGE

PHASE A PHASE B PHASE C CAUTION CAUTION 2 DISCONNECT DISCONNECT BEFORE SERVICING BEFORE SERVICING 71.25 75.00 (1809.8) (1905.0) 3 2 11.75 (298.5) 2

46.00 2 (1168.4)

2 12.00 (304.8) 3.00 2 (76.2)

2 6.00 (152.4) Legend 13.00 1. Controller Power Wire 0.438 ø 2 Filter Tray (330.2) 2. On/Off Switch Interconnect Filter Tray Mounting Holes 3. Phase A, B and C Blown Conduit 25.00 2 per Channel 2 Fuse Indicating Lights (635.0) 2 2 2 2 2 2 2 2 2 2 2 2 2 2

V3-T2-66 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Transient-Free Power Factor Correction System Contents 2 Description Page Product Overview...... V3-T2-38 2 UNIPUMP...... V3-T2-41 UNIPAK...... V3-T2-44 2 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems ...... V3-T2-55 2 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems ...... V3-T2-58 AUTOVAR Filter—LV Automatic Harmonic Filter . . V3-T2-63 2 Transient-Free Static Switching Power Factor Correction Units...... 2 Features, Benefits and Functions ...... V3-T2-68 Standards and Certifications ...... V3-T2-68 2 Catalog Number Selection ...... V3-T2-69 Technical Data and Specifications ...... V3-T2-69 2 Dimensions ...... V3-T2-70 Active-Harmonic Filter-Harmonic Correction Unit— 2 NEMA 1 Enclosure ...... V3-T2-71 2 2 Transient-Free Static Switching Power Factor Correction Units Product Description Application Description 2 Transient-free statically The FTA and FTE units ● Motor starting Rating based on Service switch capacitor units are employ a fast or real-time ● On-site generation support Entrance Ampacity. For other 2 available in two models. response, and include the ratios, please consult factory. ● Spot welding ability to switch larger steps ● ● 2 The FTE model is a real-time without creating significant Wind turbines Startup and transient-free system, used line noise. These relatively ● Other dynamic loads Commissioning by 2 to compensate extremely maintenance-free units reside factory trained personnel Three current transformers rapid loads within one in a smaller footprint and are is required for proper with a 5 ampere secondary cycle of operation (typically ideal for use in applications operation and warranty 2 are required to operate this 5–20 msec). such as flicker control, large of this system capacitor bank. The FTA model is a fast motor starting, bus voltage 2 transient-free system, used stabilization, fault ride- to compensate any loads through solutions, power 2 within 3–4 seconds. factor correction and many more. 2 2 2 2 2 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-67 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Application Example—Spot Welding Spot Welding (Auto Manufacturer) 2 2 230 2 220

210 2 Without With 1800 2 2 1400 L1-Current (A)L1-Current (V) L1-Voltage

2 1000

2 300

150

2 (kVAR) L1-Q 0 2 2 21:33:38 :40 :42 :44 :46 :48 :50 :52 :54 :56 :58 :00 :02 :04 :06 :08 2 Features, Benefits and Functions 2 ● Transient-free capacitor ● Unique SCAN feature FTE unit includes all of the group switching, using reduces capacitor above, plus: electronic switching duty cycles 2 ● Reduces voltage flicker and elements ● Remote control of voltage sag ● Simultaneous connection/ compensation systems 2 ● disconnection of all available via LAN Provides network reactive required steps or Ethernet power support 2 ● ● Consistent capacitor values ● Integrated three-phase Offers voltage control and stable filter network analyzer: options 2 characteristics ● Measures all power ● Harmonic filtration parameters on each 2 ● Three independent phase (V, I, kW, control modes: kVAR, kVA) ● 2 ● Power factor control Measures voltage and current harmonics to ● Voltage control the 63rd harmonic 2 ● Load sharing with another compensation 2 system connected to the same transformer 2

2 Standards and Certifications 2 Enclosure ● EMC—EN50081-2, ● Safety—EN61010-1, 2 EN50082-2, EN55011, EN60439-1, EN60204 EN61000-4-2/3/4/5, ● UL 508 ENV50204, ENV50141 2 ● CSA ● CE Mark—73/23/EEC am. 2 93/68, 98/37/EC art. 4(2) 2 2

V3-T2-68 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Catalog Number Selection 2 TFSS 2 FTA 100 6 2 480 P14 N12 -M3-COM 2 2 Model Optional 1 FTE = Real-time balanced Number of Groups Percent Reactory (Tuning) Enclosure COM = Communications Card 2 4 FTEUN = Real-time unbalanced Maximum 12 P14 = 14% (2.67th order) N1 = NEMA 1 RS-485/Modbus FTA = Fast acting P7 = 7% (3.8th order) N12 = NEMA 12 2 FTES = Motor starting systems P567 = 5.67% (4.2nd order) N3R = NEMA 3R 5 Switching Sequence Optional FTER = Grid fault ride-through systems P49 = 4.9% (4.5th order) 3 1 = 1:1:1:1 Measurement Levels 2 = 1:2:2:2 M2 2 Total Power in kVAR 3 = 1:2:4:4 System Voltage M3 Typical in steps of 50 kVAR 480 = 480V M4 2 beginning with 100 kVAR 600 = 600V 2 690V or above = MV 2 2 Technical Data and Specifications

Product Configurations 2 Network voltage Capacitor group Acquisition time configurations 2 ● 210–690V ● FTE—5–20 ms for a ● ● Engineered solutions Up to 12 groups per 50 Hz network 2 up to 15 kV one controller ● FTE—4–16 ms for a ● Switching sequence: 60 Hz network Frequency 2 ● 1:1:1:1 (all equal) ● FTA—1–4 second ● 45–55 Hz for 50 Hz ● 1:2:2:2 (half group) maximum 2 network ● 1:2:4:4 (quarter, half ● 55–65 Hz for 60 Hz groups) 2 network 2 Notes 1 All models are CE approved. Please notify if UL or cUL is required. 2 2 MV units require: A correctly sized and specified step-up transformer MV and LV interconnection, switching and protection 2 3 All systems are offered with Measurement Level 1 (f, I, V, kW, kVAR, kVA, PF) and no communications card. The measurement levels can be upgraded to Measurement Level 2 (adds THD I and THDV), Measurement Level 3 (adds waveforms, I and V harmonics) and Measurement Level 4 (adds event log). 2 4 Balanced system employs two-phase switching, unbalanced system employs individual three-phase switching. 5 For motor start and grid fault ride-through solutions, please consult factory. 2 2 2 2 2 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-69 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Dimensions Approximate Dimensions in Inches (mm)

2 Transient-Free Reactive Power Compensation Systems— Transient-Free Reactive Power Compensation Systems— Real-Time Transient-Free Systems—480 Vac Fast Transient-Free Switching Systems—480 Vac 2 Compensate Rapid Loads Within One Cycle 2 (Typically 5–20 ms)—Standard 6% Inductors— Compensate Any Load Within 3–4 Seconds—Standard 6% Detuned to 245 Hz (4.08th Harmonic) Inductors—Detuned to 245 Hz (4.08th Harmonic) 2 Catalog Catalog Number Width Depth Height Number Width Depth Height 2 FTE15652480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA15652480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE18752480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA18752480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 2 FTE21974480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA21974480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 2 FTE25052480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA25052480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE26274480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA26274480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 2 FTE31252480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA31252480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE37552480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA37552480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 2 FTE43774480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA43774480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE45031480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA45031480 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 2 FTE60661480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA60661480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) 2 FTE687112480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA687112480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTE75061480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA75061480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) 2 FTE825112480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA825112480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTE90061480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA90061480 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) 2 FTE112591480 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTA112591480 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTE135091480 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTA135091480 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) 2 FTE1500121480 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) FTA1500121480 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) 2 FTE1800121480 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) FTA1800121480 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) Compensate Rapid Loads Within One Cycle 2 (Typically 5–20 ms)—4.5% Inductors— Compensate Any Load Within 3–4 Seconds—4.5% 2 Tuned to 282 Hz (4.7th Harmonic) Inductors—Tuned to 282 Hz (4.7th Harmonic) Catalog Catalog 2 Number Width Depth Height Number Width Depth Height FTE15652480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA15652480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 2 FTE18752480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA18752480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE21974480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA21974480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 2 FTE25052480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA25052480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE26274480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA26274480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 2 FTE31252480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA31252480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 2 FTE37552480T 31.50 (800.1) 23.60 (599.4) 82.07 (2100.6) FTA37552480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE43774480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA43774480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) 2 FTE45031480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTA45031480T 31.50 (800.1) 23.60 (599.4) 82.70 (2100.6) FTE60661480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA60661480T 63.00 (1600.2) 23.60 (599.4) 82.07 (2100.6) 2 FTE687112480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA687112480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTE75061480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA75061480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) 2 FTE825112480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA825112480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) 2 FTE90061480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTA90061480T 63.00 (1600.2) 23.60 (599.4) 82.70 (2100.6) FTE112591480T 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTA112591480T 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) 2 FTE135091480T 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTA135091480T 94.50 (2400.3) 23.60 (599.4) 82.70 (2100.6) FTE1500121480T 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) FTA1500121480T 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) 2 FTE1800121480T 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) FTA1800121480T 126.00 (3200.4) 23.60 (599.4) 82.70 (2100.6) 2

V3-T2-70 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Harmonic Correction Units—NEMA 1 Enclosure Contents 2 Description Page Product Overview...... V3-T2-38 2 UNIPUMP...... V3-T2-41 UNIPAK...... V3-T2-44 2 AUTOVAR 300 Automatic Power Factor Correction Capacitor Systems ...... V3-T2-55 2 AUTOVAR 600 Automatic Power Factor Correction Capacitor Systems ...... V3-T2-58 2 AUTOVAR Filter—LV Automatic Harmonic Filter . . V3-T2-63 Transient-Free Static Switching Power Factor Correction Units...... V3-T2-67 2 Active-Harmonic Filter-Harmonic Correction Unit— NEMA 1 Enclosure 2 Technical Data and Specifications ...... V3-T2-72 Wiring Diagrams ...... V3-T2-72 2 Dimensions ...... V3-T2-74 2 2 2 Active-Harmonic Filter-Harmonic Correction Unit—NEMA 1 Enclosure Product Description Features, Benefits Standards and Certifications 2 Active Harmonic Filters and Functions ● UL/CSA approved (Harmonic Correction Units— Unlike passive filters, by Advantages 2 HCUEs) provide dynamic providing dynamic correction, ● Can be sized to guarantee harmonic correction by HCUEs can provide effective specific levels of harmonic 2 actively injecting equal and harmonic correction for correction, such as opposite currents into the varying load conditions and meeting IEEE 519 2 customer’s electrical harmonic spectrums up to recommended levels distribution system that their rated capacity. HCUEs ● Cannot be overloaded 2 cancel the entire spectrum also have the secondary ● Can be expanded without of harmonic currents at the benefit of providing power affecting performance point of connection. factor correction with any 2 ● Broad spectrum of excess capacity after cancellation (2nd to Application Description correcting all harmonic 50th harmonic) 2 Typical applications include conditions. locations with large amounts ● Power factor improvement ● of nonlinear loads including Fast action ● Easier and less expensive 2 6- and 12-pulse PWM AC ● NEMA 1 and NEMA 12 installation variable frequency drives, enclosures available: ● Comprehensive control 2 DC drives, as well as other ● Wallmount (50 and switch-mode 100 ampere designs) 2 equipment. This equipment ● Floor-standing can be found in water and (300 ampere design) 2 wastewater treatment facilities, industrial ● Touchscreen HMI 2 manufacturing and ● Modbus and Ethernet warehousing plants, military connectivity bases, and commercial Note: Requires at least 3% series 2 (HVAC) locations. input line reactor or equivalent 6% DC bus choke 2 in each AC drive for optimum performance. 2 2 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-71 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Technical Data and Specifications ● 20 kHz switching carrier frequency 2 ● 208–480V ±10%, 600V and 690V with autotransformer ● 50/60 Hz +/–3 Hz frequency 2 ● Ambient temperature 0°C to +40°C enclosed ● Seismic Zone 4 2 ● Output capacity—self limited to 100% current rated ● Corrective capability—<5% TDD and near unity 2 displacement power factor

2 Harmonic Control Unit Ratings—NEMA 1 Enclosed Total Current Watt Losses 2 Model Voltage Frequency Amperes (rms) (kw) Enclosure Type Disconnect HCUE050D5N1 208–480 50/60 Hz 50 1.8 Wallmount/NEMA 1 — 2 HCUE100D5N1 208–480 50/60 Hz 100 3.0 Wallmount/NEMA 1 — 2 HCUE300D5N1 208–480 50/60 Hz 300 8.0 Free-standing/NEMA 1 X HCUE050D6N1 600 50/60 Hz 39 1.8 Free-standing/NEMA 1 — 2 HCUE050D7N1 690 50/60 Hz 33 1.8 Free-standing/NEMA 1 — HCUE100D6N1 600 50/60 Hz 78 3.0 Free-standing/NEMA 1 — 2 HCUE100D7N1 690 50/60 Hz 65 3.0 Free-standing/NEMA 1 — HCUE300D6N1 600 50/60 Hz 235 8.0 Free-standing/NEMA 1 — 2 HCUE300D7N1 690 50/60 Hz 200 8.0 Free-standing/NEMA 1 — 2 1 2 Current Transformer Ratings AC Line 2 Model Current Rating Type HCUCT1000SC 1000 Split 2 HCUCT3000SC 3000 Split HCUCT5000SC 5000 Split 2 2 Wiring Diagrams 2 Installation Diagram Load(s) 2

Source 2 Typical CT Transformer Placement 2 2 2 Alternate CT Placement HCU

2 Note 1 Current transformers are rated for 400 Hz. Two current transformers are required for three- 2 phase loads. Three current transformers are required when single-phase loads are present. Rating based on service entrance ampacity and optional parallel operation. For other ratios, please consult factory. 2 Startup and commissioning by factory trained personnel is required for proper operation and warranty of this system. 2 2 2

V3-T2-72 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Source CT Location Source or Load CT Location 2 Utility Transformer Utility Transformer or or Upstream Panel Upstream Panel 2 2 Distribution Panel or Distribution Panel or Motor Control Center Motor Control Center 2 2 2 2

Corrected Corrected Corrected Other Other Load Load Load Loads Loads 2 2 2 Less than 25 Feet per NEC 240-21 2 Harmonic Cancellation and/or Power-Factor 2 Correction of all Loads HCU Three Possible on Panel HCU CT Locations 2 Corrected Shown Load 2 2 Source or Load CT Location Load CT Location

Utility Transformer Utility Transformer 2 or Upstream Panel or Upstream Panel 2 Distribution Panel or Motor Control Center Distribution Panel or 2 Motor Control Center 2 2

More than 2 25 Feet per Other Loads Other Loads NEC 240-21 2 Other Corrected Other Loads Load Loads 2 Junction Box Four Possible 2 Breaker CT Locations or Fused Shown 2 Disconnect – Harmonic Cancellation 2 and/or Power-Factor Correction of a Selected HCU HCU 2 Load on Panel Corrected Load 2 2 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-73 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Dimensions Approximate Dimensions in Inches (mm) 2 Harmonic Control—NEMA 1 Enclosed Current Transformer Exterior Model Internal Diameter 2 Unit Weight Model Height Weight Depth in Lbs (kg) HCUCT1000SC 4.65 (118.1) 2 HCUE050D5N1 51.80 (1315.7) 20.70 (525.8) 18.50 (469.9) 250 (113.5) HCUCT3000SC 6.50 (165.1) 2 HCUE100D5N1 68.70 (1745.0) 20.70 (525.8) 18.50 (469.9) 350 (158.9) HCUCT5000SC 7.50 (190.5) HCUE300D5N1 74.90 (1902.5) 32.20 (817.9) 19.50 (495.3) 775 (351.9) 2 1 111 Auxiliary Current Transformers 2 HCUE050D6N1 1 111 Model Ratio Type HCUE050D7N1 2 HCUE100D6N1 1 111 HCUCT7RL6011 600/1 Solid round core HCUE100D7N1 1 111 HCUCT7RL1021 1000/1 Solid round core 2 1 111 HCUE300D6N1 Notes 1 HCUE300D7N1 1 111 Consult factory. 2 2 Required for parallel operation of HCU and for units with transformers. Use the same number of auxiliary CTs as main sensing CTs. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

V3-T2-74 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Approximate Dimensions in Inches (mm) 2 Drawings—NEMA 1 Enclosure HCUE050 Layout Dimensions 2 The HCUE050 series offers 50 amperes of corrective current in a convenient package. The enclosed model comes standard with a 2 digital interface panel for control diagnostics and programming. Input fuses are included. The enclosed unit includes a removable 2 panel for bottom conduit entry. 2 HCUE050—50 Amperes, 208–480V 20.70 2 (525.8) 9.80 Heat Sink Opening 2 (249.0) 2 2 4.60 (116.8) 2 2

16.70 18.70 (424.2) (475.0) 2 2 2 20.60 (523.2) 2 5.10 (129.5) 2 2 HMI 4.00 (101.6) 67.20 68.70 2 (1706.9) (1745.0)

5.90 2 (149.9) 2 2 2 2 2

5.30 2 (134.6) 2 Conduit Plate 6.30 (160.0) 2 5.70 6.30 (144.8) 2 (160.0) Inlet Air Opening 8.90 2 (226.1) 5.30 (134.6) 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-75 SPD, Power Conditioning, PF Capacitors and Harmonic Filters 2.2 Power Factor Correction and Harmonic Filtering

2 Approximate Dimensions in Inches (mm) HCUE100 Layout Dimensions 2 The HCUE100 series offers 100 amperes of corrective current in a wallmounted NEMA 1 enclosure. The enclosed model comes standard with a digital interface module for control, diagnostics 2 and programming. Input fuses are included. The enclosed unit 2 includes a removable panel for bottom conduit entry.

2 HCUE100—100 Amperes 208–480V

20.70 2 (525.8) 9.80 Heat Sink Opening 2 (249.0) 2

2 4.60 (116.8) 2 2 16.70 18.70 2 (424.2) (475.0) 2

2 20.60 (523.2) 2 5.10 2 (129.5)

2 HMI 4.00 (101.6) 67.20 68.70 2 (1706.9) (1745.0)

5.90 2 (149.9) 2 2 2 2 2 5.30 2 (134.6)

2 Conduit Plate 6.30 (160.0) 2 5.70 6.30 (144.8) 2 (160.0) Inlet Air Opening 8.90 2 (226.1) 5.30 2 (134.6)

V3-T2-76 Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com SPD, Power Conditioning, PF Capacitors and Harmonic Filters Power Factor Correction and Harmonic Filtering 2.2

Approximate Dimensions in Inches (mm) 2 HCUE300 Layout Dimensions The HCUE300 series offers 300 amperes of corrective current 2 for large capacity applications. It is available in a floor-standing NEMA 1 enclosure (including a door-interlocking disconnect). The enclosed model comes standard with digital interface module 2 for control, diagnostics and programming. Input fuses are included. The enclosed unit includes a removable panel for 2 top conduit entry. 2 HCUE300—300 Amperes 208–480V 2 32.00 (812.8) 2 23.20 (589.3) 3.10 (78.7) 2 Conduit Plate 2 6.50 (165.1) Heat Sink Opening 2 2

8.00 (203.2) 21.80 2 (553.7) 28.90 17.10 2 (734.1) (434.3) 2

14.80 2 (375.9)

HMI 2

5.10 2 4.00 (129.5) (101.6) 2

7.40 74.80 77.10 2 (188.0) (1899.9) (1958.3) 2 10.80 (274.3) 2

12.50 2 (317.5) Inlet 2 Air Opening 2 2 0.60 24.30 4X (15.2) (617.2) 0.40 2 4X (10.2) ”A“ 2

14.70 2 (373.4) Detail ”A“ 2 Scale 1:12 2

Volume 3—Power Distribution and Control Assemblies CA08100004E—April 2014 www.eaton.com V3-T2-77