Eaton Power Conditioner Product Catalog

Eaton Power Conditioner Product Catalog

Electronic voltage regulator Harmonic correction unit Power-Sure 700 & 800 Sag ride-through power Power conditioning products Power-Suppress 100 & 600 conditioner The power to work Basics of power quality The partner you can trust The PQ PyramidE Utilities struggle to keep up with the unrelenting The key elements of an effective demand for clean power…you can’t rely solely on PQ strategy: them to provide it. The responsibility for PQ rests Interruption solutions Surge protection with the customer—including you. • Reduce problems associated • Eliminates problems associated With Eaton behind you, your company’s operations with outages using UPS, with transients traveling on ac, paralleling switchgear, telephone and communication managers and facility engineers can be assured that generators and/or energy lines their power supply will get the job done, no matter storage devices what level of reliability your company requires. Effective grounding Harmonic mitigation • A well-designed and You wouldn’t use anything other than 100 percent • Many applications require properly installed grounding clean gas in your car, or pure oil in your engine. solutions to reduce harmonic system is required for current and voltage distortion safety and operation of all The same rules apply to your electrical equipment. electrical equipment Without an investment in the quality of power Voltage regulation running this equipment, you can expect downtime • Stabilizes a facility’s voltage and equipment disruption. and eliminates costly problems due to undervoltage and overvoltage events Outages Interruptions High Harmonic $/kVA Distortion Solution Voltage Variations and Sags Voltage Surges Grounding/ Bonding Low $/kVA Solution PQ Pyramid EATON Power conditioning products 2 A total solution The right power quality solution Transfer Harmonic is site and industry specific. Power Switches Mitigating Transformer quality meters are required to help Protective K-Factor you capture and analyze your Relays Transformer facility’s power disturbances. If you Predictive Grounding can’t measure it, you can’t manage it. Diagnostics/ and Partial Lighting Discharge Systems A power quality engineer can help Uninterruptible Power companies interpret data and identify Power Supply Factor the most cost-effective solutions. Correction With today’s increasingly complex facilities and interconnected Other Harmonic Power networks, the number of problems Solutions Distribution that can result from poor power quality are significant. Eaton power Surge Generation system engineers are PQ experts Protection Switchgear who can help you realize the full benefits of your investment. Isolation Power Transformers Quality Armed with this information, Meters Sag Voltage you can select the Eaton Correction Regulation products that are right for you. EATON Power conditioning products 3 Solutions to all of your needs power quality An investment in Eaton power quality (PQ) solutions is one that will pay dividends immediately. It keeps your equipment, and your company, working. That means you avoid costly downtime. We’ll help you protect your investment in an increasingly digital world. Overview Eaton offers a wide range of power conditioning solutions. These solutions range from small single-phase isolation units to megawatt sag correction units. Eaton has the engineering expertise and products to solve your power quality problem. Protects equipment from: Ratings • Voltage sags • 500 VA to 50 MVA • Line noise • 50/60 Hz • Voltage transients/surges • Voltage 120 V to 36 kV • Under/overvoltage events • Single-phase and three-phase • Swells • Harmonics EATON Power conditioning products 4 Power conditioning product selection chart Eaton power conditioning products are designed to protect your critical equipment against common power quality problems. Power Power quality Transient Noise Voltage Voltage sag Harmonic interruption Power factor product/protection activity suppression regulation correction protection protection Isolation correction Uninterruptible power supply n n n n n n Power-SureE 700 n n n n n n Power-SureE 800 n n n n n n Power-SuppressE 600 n n n n Power-SuppressE 100 n n n n Surge protective devices n n Sag ride-through devices (SRT2) n n n Harmonic correction units (HCU2) n n Power conditioning application chart Power Power quality Single- Three- Test Audio Data interruption Factory Critical product/protection phase phase equipment systems centers protection Isolation automation systems Uninterruptible power supply n n n n n n Power-SureE 700 n n n n n Power-SureE 800 n n n n n Power-SuppressE 600 n n n n n Power-SuppressE 100 n n n n n Surge protective devices n n n n n n n Sag ride-through devices (SRT2) n n n n Harmonic correction units (HCU2) n n n n EATON Power conditioning products 5 Power conditioning voltage regulators Power-Sure 700— Power-Sure 800— Sag ride-through three-phase single-phase power conditioner (SRT2) • Ratings from 10 kVA to • Ratings from 500 VA to 25 kVA • Up to 30 seconds of voltage 500 kVA sag ride-through • Voltage range from • Voltage from 208 V to 600 V 120 V to 480 V • 99% efficient (typical) • Seven taps per phase for • Office models • Does not lower fault capacity optimal regulation (with receptacles) • Continuous voltage regulation • Response time of 1/2 cycle • Hardwired models (wall/panel • Voltage harmonic reduction mount and floor mount) • Output correction within • Voltage balance correction 1.5 cycles • Line regulation ±3% V-out for +10% to –20% V-in at • Extensive diagnostics • ±3% voltage output for a 100% load +10% to –23% voltage input • Voltage event log • Load regulation ±3% for • Less than 1% THD • 0–75% load to ±2% for Separate coupling transformer • Unit not affected by load 100% load • Continuous sag correction power factor survives multiple sag events • Immunity to distortion at 40% without recharging capacitors • High efficiency of THD V-in, 5% max. THD V-out for extra time savings approximately 97% • Ride-through capability of • Small design and footprint • Frequency range of 57–63 Hz 1 cycle significantly reduces required • Bypass switch (optional on • Voltage recovery of 2 cycles to floor space 45 kVA and smaller units) 95%, 3 cycles to 100% • Battery-free design eliminates • Triple-shielded isolation • K-30 rated K-factor costly maintenance and transformer disposal requirements • Harmonic attenuation of • Overtemperature protection –23 dB for load-reflected • No minimum load improves harmonics operating flexibility for • Optional surge protection unit fluctuating loads or processes • Surge protection of 330 V • Optional metering let-through voltage • Sub-cycle response patented • Front access only for circuit enables extremely fast • Common mode noise 2 ms response (1/8 cycle) Power-Sure 700 50–150 kVA units attenuation of 140 dB • One-year warranty • Transverse mode noise attenuation of 120 dB • Reliability of 200,000 hours (MTBF) • Audible noise of 52–56 dB at 1 meter • Efficiency of 92% at full load • Operating temperature of –20 °C to +40 °C • Two-year warranty Power-Sure 800 Sag ride-through (SRT2) EATON Power conditioning products 6 Power conditioning and isolation Power-Suppress 100— Power-Suppress 600 Harmonic correction unit single-phase isolation transformer • Can be sized to guarantee • Traps unwanted harmonics • Common mode noise specific levels of harmonic attenuation: correction, such as meeting • Sizes from 500 VA to 7.5 kVA IEEET 519 recommended • 126 dB—standard double • Voltages from 120 V to 480 V (2) shield levels • Common mode noise • Cannot be overloaded • 146 dB—optional triple attenuation of 140 dB (3) shield • Can be expanded without at 100 kHz affecting performance • Transverse mode noise • Normal mode noise attenuation: • Broad spectrum of cancellation attenuation of 65 dB (2nd to 51st harmonic) at 100 kHz • 3 dB down at 10 kHz, decaying 20 dB per decade • Power factor improvement • Overload capacity of 600% for 1 cycle, 300% for 30 seconds • Decaying 40 dB with • Easier and less expensive “SPD With High installation • Frequency of 60 Hz ±5% Frequency” option • Comprehensive control • Efficiency of 93–97% • Overload capacity up to • Fast action • Adds less than 1% THD 500% for 10 seconds, under linear loading 1000% for 1 cycle • 20 kHz switching carrier frequency, 25 μs full • Temperature rise 115 °C above • K-13 rated response time a 40 °C ambient • Overtemperature protection • UL/CSAT approved • Removes surge voltages and • Clean, noise-free power minimizes reflected THD • 380–480 V ±10%, 600 V and output 690 V with autotransformer • Cleans and conditions the • Fast, easy installation sine wave • 50/60 Hz ±3 Hz frequency • Optional ULT 1449 4th Edition • Eliminates load-generated • Ambient temperature 0 °C and UL 1283 7th Type 2 feedback to +40 °C enclosed surge suppressor • Available in both hardwired or • Seismic Zone 4 • UL and cULT listed Harmonic Correction Unit line cord/receptacle models requirements • NEMA 1, NEMA 2, NEMA 12, • Fast and easy installation IP31, IP54 and chassis-mount • Frequency of 60 Hz ±5% versions available: • Long-life operation • Efficiency: • Wallmount (NEMA 1 • Small footprint • Meets and exceeds U.S. designs) • Two-year warranty Department of Energy • Floor-standing (NEMA 2, (DOE) 2016 high efficiency NEMA 12, IP31 and IP54) standards identified under DOE 10 CFR Part 431 • Output capacity—self-limited to 100% current rated • Meets and exceeds CSA Standard C802.2-12 • Corrective capability— <5% TDD and near unity • Output impedance 2% to displacement power factor A 3.5% typical • Color HMI touchscreen display • Output distortion less than Power-Suppress 100 1.0% THD added under • Efficiency: losses at 480 V linear load <3%; losses at 690 V <5% • The solated neutral establishes • Closed loop control a new neutral to ground bond on the transformer’s output A Requires at least 3% series input line reactor ahead of large nonlinear loads. • Protects loads from voltage and current distortions caused from triplen harmonics (3rd, 9th, 15th, 21st, etc.) • One-year warranty Power-Suppress 600 EATON Power conditioning products 7 We make what matters work.* At Eaton, we believe that power is a fundamental part of just about everything people do.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    8 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us