AES “WOLF” Walk-On Light Fixture for Cleanrooms Walk Safely with AES

Total Page:16

File Type:pdf, Size:1020Kb

AES “WOLF” Walk-On Light Fixture for Cleanrooms Walk Safely with AES AES “WOLF” Walk-On Light Fixture for Cleanrooms Walk Safely with AES WOLF. AES “WOLF” is our exclusive, USA manufactured, flush, top access cleanroom Walk-On Light Fixture designed specifically for integration into our AES 2” or 3” Walk-On Ceiling System. With safety in mind, the WOLF is designed with a flush top and structural reinforcement built-in, effectively preventing a potential trip hazard that exists with other units, and possible fall-through while servicing the FEATURES fixture with its lid off. These features eliminate the need for costly and cumbersome after-market cages or barriers that are often built on top • Recessed ceiling mount; flange, top access lift-off lid – 1’×4’, of other lights. 2’×2’, 2’×4’ These easy-to-clean fixtures meet IP65 ingress protection, ensuring both • One-piece overlapping door for 2” or 3” thick AES Ceiling protection against particulate contamination and integrity of pressurized plenums where applicable. The unit is designed to meet the highest • No visible fasteners on roomside cleanliness standards and most stringent cleaning protocols – including • Long-life efficient LED lamp sources for accurate color rendition those that may involve caustic chemicals and extreme abrasion. and lighting performance • UL and CUL listed for wet locations; UL classified IP65 Toll-Free: 888-AES-CLEAN Email: [email protected] aesclean.com 1’ x 4’ 2’ x 2’ 2’ x 4’ Ordering Information (Ex: AES2ROL-24-67L40K-DDC-DV_2F-2H-SYM) MODEL: AES2ROL / AES3ROL SIZE: 14 (1’ x 4’); 22 (2’ x 2’); 24 (2’ x 4’) LAMP TYPE: Product Specs 1’ x 4’ 2’ x 2’ 45L35K 45 Watt 3500K LED (82 CRI) 45L35K 45 Watt 3500K LED (82 CRI) • Housing: 16-Gauge CRS. Four-piece welded construction 45L40K 45 Watt 4000K LED (82 CRI) 45L40K 45 Watt 4000K LED (82 CRI) with TGIC polyester powder coat finish. 45L50K 45 Watt 5000K LED (82 CRI) 45L50K 45 Watt 5000K LED (82 CRI) • Walk-on Load Capacity: Fixture static testing sustained load results: up to 44psf. Traverse load testing of fixtures installed 67L35K 67 Watt 3500K LED (82 CRI) 67L35K 67 Watt 3500K LED (82 CRI) in AES ceiling panel results: 75psf maintained load. 67L40K 67 Watt 4000K LED (82 CRI) 67L40K 67 Watt 4000K LED (82 CRI) • Top Access Door: Full size 16-gauge CRS continuous door 67L50K 67 Watt 5000K LED (82 CRI) 67L50K 67 Watt 5000K LED (82 CRI) has flanged return, two D-ring recessed finger latches, and door secured to housing with 8 (2’×2’) or 10 (1’×4’ or 2’×4’) 2’ x 4’ stainless steel 8-32 Philips flat head screws – recessed into top access door. 45L35K 45 Watt 3500K LED (82 CRI) 90L35K 90 Watt 3500K LED (82 CRI) • Doorframe: 18-Gauge 304SS. One-piece 60° beveled 45L40K 45 Watt 4000K LED (82 CRI) 90L40K 90 Watt 4000K LED (82 CRI) perimeter construction. Continuous lens retention system. 45L50K 45 Watt 5000K LED (82 CRI) 90L50K 90 Watt 5000K LED (82 CRI) Doorframe attaches to housing with 6 locknuts (2’×2’) or 8 locknuts (1’×4’ or 2’×4’). No fasteners visible from room side, 67L35K 67 Watt 3500K LED (82 CRI) 135L35K 135 Watt 3500K LED (82 CRI) tethered with steel aircraft cables. 67L40K 67 Watt 4000K LED (82 CRI) 135L40K 135 Watt 4000K LED (82 CRI) • Lens: .125” high impact diffused acrylic lens sealed to 67L50K 67 Watt 5000K LED (82 CRI) 135L50K 135 Watt 5000K LED (82 CRI) perimeter ledge of lens aperture with silicone sealant and DRIVER TYPE: secured with continuous lens retention system. • Gasket Materials: One-piece closed cell extruded DCC Dimming Constant Current silicone gasket seals doorframe to ceiling structure. VOLTAGE: Closed cell extruded silicone gasketing seals top access door to housing. DV 120/277VAC, 50/60Hz 347 347/VAC • Finish: White TGIC polyester powder coat 5 step DOORFRAME OPTIONS: pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. 5F 18-Ga Type 304 SS (STD) XF 18-Ga Type 316 SS • Electrical: Available 350 0K, 4000K and 5000K color .063” Painted 2F 18-Ga CRS PAF temperatures. 120-277VAC, 347VAC, 50/60Hz electrical Fabricated Aluminum input with serviceable high power factor electronic, HOUSING OPTIONS: OPTICS: constant-current driver (<20% THD, >0.95 PF). Standard 0-10V dimming with 3-100% range. 2H 20-Ga CRS (STD) SYM Symmetric, Diffused DR Acrylic • Fixture Designed to Fit: 2” or 3” thick AES walk-on OPTIONS: type ceiling system. Emergency Battery Fuse & Food Zone/ LEL* FS FN** • Warranty: Limited five (5) year warranty. Pack Holder Non-Contact • Listings: UL and CUL Listed for Wet Location. UL certified * LEL for 2” ceiling only available remote mounted IP65 in compliance with IEC 60598. NSF2 Splash/Non-Food ** Lensing consists of FDA-approved Food Zone Zone. FED-STD-209E/Class 100 (ISO 5) Cleanrooms. clear polycarbonate outer lens and diffused acrylic inner lens JOB NAME & # FIXTURE TYPE CATALOG NUMBER APPROVED BY & DATE Performance: (2” or 3” Ceiling) Initial Delivered Lumens Lamp @ 25°C 2”/ Efficacy (lm/W) Input Power (W) Drive Current Estd. L70 LED Life Model Type 3” 2”/ 3” 2”/ 3” (mA) (Hrs) 45L35K 4857/4835 97/97 50/50 94 80,000 45L40K 5178/5154 104/103 50/50 94 80,000 AES2ROL14 45L50K 5385/5360 108/107 50/50 94 80,000 AES3ROL14 67L35K 7224/7191 98/97 74/74 66 80,000 67L40K 7701/7666 104/104 74/74 66 80,000 67L50K 8009/7973 108/108 74/74 66 80,000 45L35K 4728/4780 95/96 50/50 94 80,000 45L40K 5040/5096 101/102 50/50 94 80,000 AES2ROL22 45L50K 5242/5300 105/106 50/50 94 80,000 AES3ROL22 67L35K 7031/7109 95/96 74/74 66 80,000 67L40K 7496/7579 101/102 74/74 66 80,000 67L50K 7796/7882 105/107 74/74 66 80,000 45L35K 5086/4834 102/97 48/50 94 80,000 45L40K 5422/5153 108/103 48/50 94 80,000 45L50K 5639/5359 113/107 48/50 94 80,000 67L35K 7564/7189 102/97 73/74 66 80,000 67L40K 8064/7664 109/104 73/74 66 80,000 AES2ROL24 67L50K 8386/7970 113/108 73/74 66 80,000 AES3ROL24 90L35K 9659/9180 97/92 98/100 94 60,000 90L40K 10298/9787 103/98 98/100 94 60,000 90L50K 10710/10179 107/102 98/100 94 60,000 135L35K 14883/14144 99/94 148/150 94 60,000 135L40K 15867/15079 106/101 148/150 94 60,000 135L50K 16501/15683 110/105 148/150 94 60,000 Displayed information is for selected luminaries only. Dimensional Data (in Inches): (AES2ROL/AES3ROL LED Series) A B C D E F 1’ x 4’ 51.11 14.6 50.11 13.54 49.06 12.56 2’ x 2’ 27.11 24.60 26.11 23.54 25.06 22.56 2’ x 4’ 51.11 24.60 50.11 23.54 49.06 22.56 Detail View Cross Section Top View Bottom View Recommended Ceiling Cutout This information should be used in conjunction with the associated technical data, specifications and related documents to establish the total requirements for the unit. The information in this document is subject to change without notice. AES assumes no responsibility for any errors that may inadvertently appear in this document. 09/19 Toll-Free: 888-AES-CLEAN Email: [email protected] aesclean.com.
Recommended publications
  • Lighting and Electrics
    Lighting and Electrics 1 1E See also: First Electric 2 P&G See also: Pin Connector 2-fer See also: Two-fer 2/0 Pronounced 2-aught; single conductor cable with wire size "2/0" on jacket; commonly used for feeder cable 2PG See also: Pin Connector 3-fer See also: Three-fer 4/0 Pronounced 4-aught; single conductor cable with wire size "4/0" on jacket; commonly used for feeder cable A Adapter Electrical accessory that transitions between dissimilar connectors; may be a molded unit, box or cable assembly Amp See also: Amperes Amperes Unit of measure for the quantity of electricity flowing in a conductor Synonym: A, Amp, Current AMX192 Analog Multiplexing protocol for transmitting control information from a console to a dimmer or other controllable device Synonym: AMX, USITT AMX192 eSET: Lighting & Electrics 2 Ante-proscenium See also: Front of House (FOH) Beam Asbestos Skirt Obsolete term See also: Flameproof Apron Automated Fixtures See also: Automated Luminaire Automated Lighting Control Console Lighting console capable of controlling automated luminaires Automated Luminaire Lighting instrument with attributes that are remotely controlled Synonym: Automated Fixture, Automated Light, Computerized Light, Intelligent Light, Motorized Light, Mover, Moving Light, More… Automated Yoke Remotely controlled pan and tilt device Synonym: Yokie B Backlight A lighting source that is behind the talent or subject from the viewers perspective Synonym: Backs, Back Wash, Bx, Hair Light, Rim Light Backs See also: Backlight Balcony Front See also: Balcony Rail
    [Show full text]
  • Delamping in Most of Our Classroom Light Fixtures, There Are One to Four Individual Fluorescent Lamps
    Delamping In most of our classroom light fixtures, there are one to four individual fluorescent lamps. Depending on the types of fixtures, you can remove one of the lamps while keeping the others in. Which one to take out simply depends on which appears best to you. On the newer, skinnier (T-8) lamps, the manufacturer recommends that no more than one lamp be removed from the fixture. Delamping is a simple way to reduce foot-candles of light intensity in an area. In the lighting industry, foot-candles are a common unit of measurement used to calculate adequate lighting levels of workspaces in buildings or outdoor spaces. Of course, you can also remove all the lamps in a fixture if the light is not needed at all. Some overhead light fixtures are also emergency lights that will stay on when the building loses power. The emergency light fixtures should not be deplamped. Delamping should done by qualified staff only. Keep in mind these rules for delamping: Do not compromise health, safety, or security. Do not take lamps out of new fixtures that are still covered under warranty. Do consider the needs of the building occupants. With T-8 systems, do not remove more than one lamp per fixture. Maintain recommended minimum light levels. Refer to the chart on the next page. Where would you delamp a light fixture? Delamping is possible anywhere there is a fluorescent light fixture above an area that is not being used for active reading and writing or in areas where there is more light than needed.
    [Show full text]
  • Lighting Retrofit Manual
    Lighting Retrofit Manual Technical Report Lighting Retrofit Manual TR-107130-R1 Final Report, April 1998 Prepared for Electric Power Research Institute 3412 Hillview Avenue Palo Alto, California 94304 EPRI Project Manager J. Kesselring DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES THIS REPORT WAS PREPARED BY THE ORGANIZATION(S) NAMED BELOW AS AN ACCOUNT OF WORK SPONSORED OR COSPONSORED BY THE ELECTRIC POWER RESEARCH INSTITUTE, INC. (EPRI). NEITHER EPRI, ANY MEMBER OF EPRI, ANY COSPONSOR, THE ORGANIZATION(S) BELOW, NOR ANY PERSON ACTING ON BEHALF OF ANY OF THEM: (A) MAKES ANY WARRANTY OR REPRESENTATION WHATSOEVER, EXPRESS OR IMPLIED, (I) WITH RESPECT TO THE USE OF ANY INFORMATION, APPARATUS, METHOD, PROCESS, OR SIMILAR ITEM DISCLOSED IN THIS REPORT, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, OR (II) THAT SUCH USE DOES NOT INFRINGE ON OR INTERFERE WITH PRIVATELY OWNED RIGHTS, INCLUDING ANY PARTY'S INTELLECTUAL PROPERTY, OR (III) THAT THIS REPORT IS SUITABLE TO ANY PARTICULAR USER'S CIRCUMSTANCE; OR (B) ASSUMES RESPONSIBILITY FOR ANY DAMAGES OR OTHER LIABILITY WHATSOEVER (INCLUDING ANY CONSEQUENTIAL DAMAGES, EVEN IF EPRI OR ANY EPRI REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES) RESULTING FROM YOUR SELECTION OR USE OF THIS REPORT OR ANY INFORMATION, APPARATUS, METHOD, PROCESS, OR SIMILAR ITEM DISCLOSED IN THIS REPORT. ORGANIZATION(S) THAT PREPARED THIS REPORT ELEY ASSOCIATES ORDERING INFORMATION Requests for copies of this report should be directed to the EPRI Distribution Center, 207 Coggins Drive, P.O. Box 23205, Pleasant Hill, CA 94523, (510) 934-4212. Electric Power Research Institute and EPRI are registered service marks of Electric Power Research Institute, Inc.
    [Show full text]
  • Lighting Dictionary
    lighting dictionary the got light survival guide © got light. | 415-863-4300 | www.got-light.com lighting dictionary Below is a quick list of most commonly used technical terminology in lighting. Use and abuse this list to help navigate your way through the design process. Not enough new vocabulary for one sitting? Let us know how we can help! COPPER HOOKS A great solution for exterior pathway illumination. Copper Hooks come in six or eight foot heights, on rustic copper bases or ground stakes, that add light, as well as a decorative element. Illuminated lanterns or rustic pacific globes are paired with the hooks to surround a dining area, illuminate a lawn, driveway, or patio area. COVER, SHIELD, WRAP A cover is a Got Light must! A cover or shield is simply a three-sided masking tool to hide an uplight (and wires) so you don’t see the ugly equipment that makes a beautiful room come alive. Covers come in varying or custom colors to blend into the venue walls or architecture. A “wrap” is no different, except it’s made of custom velvet and surrounds a lighting TREE or pole to help disguise and hide the equipment that makes the magic happen. DAPPLE Dapple is a term used for “soft textured light”, created by using a GOBO in a light fixture to create shadow and texture. Dapple is commonly used when you don’t want a stylized gobo or motif and the end goal is soft diffusion. Often “dappled” light looks like subtle, natural soft light through leaves or branches, for a more organic design.
    [Show full text]
  • Light-Emitting Diode - Wikipedia, the Free Encyclopedia
    Light-emitting diode - Wikipedia, the free encyclopedia http://en.wikipedia.org/wiki/Light-emitting_diode From Wikipedia, the free encyclopedia A light-emitting diode (LED) (pronounced /ˌɛl iː ˈdiː/[1]) is a semiconductor Light-emitting diode light source. LEDs are used as indicator lamps in many devices, and are increasingly used for lighting. Introduced as a practical electronic component in 1962,[2] early LEDs emitted low-intensity red light, but modern versions are available across the visible, ultraviolet and infrared wavelengths, with very high brightness. When a light-emitting diode is forward biased (switched on), electrons are able to recombine with holes within the device, releasing energy in the form of photons. This effect is called electroluminescence and the color of the light (corresponding to the energy of the photon) is determined by the energy gap of Red, green and blue LEDs of the 5mm type 2 the semiconductor. An LED is usually small in area (less than 1 mm ), and Type Passive, optoelectronic integrated optical components are used to shape its radiation pattern and assist in reflection.[3] LEDs present many advantages over incandescent light sources Working principle Electroluminescence including lower energy consumption, longer lifetime, improved robustness, Invented Nick Holonyak Jr. (1962) smaller size, faster switching, and greater durability and reliability. LEDs powerful enough for room lighting are relatively expensive and require more Electronic symbol precise current and heat management than compact fluorescent lamp sources of comparable output. Pin configuration Anode and Cathode Light-emitting diodes are used in applications as diverse as replacements for aviation lighting, automotive lighting (particularly indicators) and in traffic signals.
    [Show full text]
  • (12) United States Patent (10) Patent No.: US 6,955,439 B2 Reismiller Et Al
    USOO695.5439B2 (12) United States Patent (10) Patent No.: US 6,955,439 B2 Reismiller et al. (45) Date of Patent: Oct. 18, 2005 (54) DUAL FILAMENT STATIC BENDING LAMP 3,855,462 A 12/1974 Kondo ........................ 362/36 4,638,408 A * 1/1987 Wetherington .............. 362/211 (75) Inventors: Philip A. Reismiller, Frankton, IN 4.945.453 A 7/1990 Serizawa et al. (US); Tony E. Collins, Alexandria, IN 5,060,120 A 10/1991 Kobayashi et al. (US) 5,517,389 A 5/1996 Myers 5,725,298 A 3/1998 Kaze et al. (73) Assignee: Guide Corporation, Pendleton, IN 6,049,7495,931,572 A 8/19994/2000 KyashiGotoh (US) 6,068.391. A 5/2000 Saladin et al. 6,409,369 B1 6/2002 De Lamberteri (*) Notice: Subject to any disclaimer, the term of this 6,439,739 B1 8/2002 sh. elee patent is extended or adjusted under 35 6,443,602 B1 9/2002 Tanabe et al. U.S.C. 154(b) by 0 days. 6,481,876 B2 * 11/2002 Hayami et al. ............. 362/.464 2002/0039289 A1 4/2002 Kinouchi 2002/0109998 A1 8/2002 Nouet et al. (21) Appl. No.:y - - - 10/372,5909 (22) Filed: Feb. 21, 2003 * cited by examiner (65) Prior Publication Data Primary Examiner John Anthony Ward Assistant Examiner Bao Q. Truong US 2004/0165373 A1 Aug. 26, 2004 (74) Attorney, Agent, or Firm-Ice Miller (51) Int. Cl. .................................................. B60Q 1/12 (57) ABSTRACT (52) U.S. Cl. .......................................... 362/36; 362/212 (58) Field of Search ................................. 362/362,212, The present invention comprises a bending lamp apparatus 362/39–43, 45, 48, 464, 465, 211, 213, and method of use.
    [Show full text]
  • Clarifying Amendements: Headlights and Auxiliary Lights: Final Rule
    Tuesday, March 16, 2004 Part V Department of Transportation Federal Railroad Administration 49 CFR Part 229 Railroad Locomotive Safety Standards: Clarifying Amendments; Headlights and Auxiliary Lights; Final Rule VerDate jul<14>2003 17:13 Mar 15, 2004 Jkt 203001 PO 00000 Frm 00001 Fmt 4717 Sfmt 4717 E:\FR\FM\16MRR3.SGM 16MRR3 12532 Federal Register / Vol. 69, No. 51 / Tuesday, March 16, 2004 / Rules and Regulations DEPARTMENT OF TRANSPORTATION online instructions for submitting having a minimum luminous intensity comments. of 200,000 candela. In the early to mid- Federal Railroad Administration Instructions: All submissions must 1990s, with the advent of locomotive include the agency name and docket auxiliary lights, the railroad industry 49 CFR Part 229 number or Regulatory Identification began using the 350-watt lamp in both [Docket No. FRA–2003–14217; Notice No. Number (RIN) for this rulemaking. Note headlight and auxiliary light fixtures. 2] that all petitions for reconsideration will Controlled testing of auxiliary lights be posted without change to http:// performed for FRA by the Volpe RIN 2130–AB58 dms.dot.gov including any personal National Transportation Systems Center information. Please see the ‘‘General (Volpe) in 1995 used regular production Railroad Locomotive Safety Standards: Information’’ heading in the 350-watt lamps. A single 350-watt lamp Clarifying Amendments; Headlights SUPPLEMENTARY INFORMATION section of tested by the U.S. Coast Guard for the and Auxiliary Lights this document for Privacy Act Volpe test, as well as data supplied by AGENCY: Federal Railroad information related to any submitted the lamp vendor, showed a center beam Administration (FRA), DOT.
    [Show full text]
  • Study of Museum Lighting and Design
    STUDY OF MUSEUM LIGHTING AND DESIGN Approved: ____________________________ Dr. Heather C. Galloway Director, University Honors Program Approved: ____________________________ Dr. Hegde Department of Family Consumer Science Supervising Professor STUDY OF MUSEUM LIGHTING AND DESIGN HONORS THESIS Presented to the Honors Committee of Texas State University-San Marcos In Partial Fulfillment of the Requirements For Graduation in the University Honors Program By Elizabeth Gay Hunt San Marcos, Texas May 2009 STUDY OF MUSEUM LIGHTING AND DESIGN ABSTRACT A museum is a place to discover, explore and learn about the past, present and future of creativity, as well as history. Lighting plays a significant role in developing interaction between humans and museum artifacts in one defined space. " Museums are places where lighting design is critical to the overall experience”(Lowe,43, 2009). Lighting is essential for human interaction in a space. Technical illumination research lays a foundation to conduct analysis in a variety of museums. This research component is significant to understand the complexity and various facets of overall museum lighting design. This study evaluates both the quantitative and qualitative aspects of lighting design in four museums. Psychological, physiological and experiential components are observed in these museums’ environments to analyze lighting design within its exhibits. My observations and knowledge gained by studying these museums help influence and enhance the design of the Cedar Hill Museum of History. 3 DEDICATION This Honor Thesis is dedicated in memory of my mother, Carolyn T. Hunt. She instilled in me the idea that we live a short time on Earth. She often said, “We are given talents that we must give back to the community and help others.” The Cedar Hill Museum of History lighting design is a reflection of how she contributed to the community of Cedar Hill and helped mold the community into what is today.
    [Show full text]
  • Lighting Design Manual
    TABLE OF CONTENTS CHAPTER 1: GENERAL REQUIREMENTS 1.1 PURPOSE 1.2 RESPONSIBILITY 1.3 COORDINATION 1.3.1 PLANNING AND DESIGN 1.3.2 INSTALLATION 1.4 DESIGN STANDARDS AND CODES 1.4.1 GENERAL 1.4.2 VA STANDARDS 1.4.3 OTHER STANDARDS AND CODES 1.5 DAYLIGHTING 1.5.1 GENERAL 1.6 ABBREVIATIONS 1.7 GLOSSARY CHAPTER 2: LIGHTING DESIGN REQUIREMENTS 2.1 ENERGY CONSERVATION 2.2 LIGHTING DESIGN STRATEGIES 2.3 LIGHTING DESIGN OBJECTIVES 2.3.1 INTERIOR 2.3.2 EXTERIOR 2.4 LIGHTING CONTROL DESIGN STRATEGIES AND OBJECTIVES 2.5 LIGHTING CONTROL DESIGN METHODOLOGIES 2.5.1 INTERIOR 2.5.2 EXTERIOR 2.6 LUMINAIRE SELECTION GUIDELINES 2.6.1 INTERIOR 2.6.2 EXTERIOR 2.7 LIGHT SOURCE SELECTION GUIDELINES 2.7.1 FLUORESCENT 2.7.2 HIGH INTENSITY DISCHARGE (HID) 2.7.3 LIGHT EMITTING DIODES (LED) 2.8 BALLAST AND LED DRIVER SELECTION GUIDELINES 2.8.1 FLUORESCENT BALLAST 2.8.2 HID BALLAST 2.8.3 LED DRIVER 2.9 EMERGENCY POWER PACK SELECTION GUIDELINES 1 TABLE OF CONTENTS 2.10 LIGHTING CONTROL SELECTION GUIDELINES 2.11 LIGHTING CALCULATIONS 2.12 LIGHTING SYSTEM COMMISSIONING 2.13 LIGHTING MAINTENANCE CONSIDERATIONS CHAPTER 3: EXTERIOR LIGHTING GUIDELINES 3.1 ROADWAYS 3.2 OPEN PARKING AREAS 3.3 WALKWAYS 3.4 ENTRIES 3.5 LANDSCAPE 3.6 BUILDING PERIMETER 3.7 FLAGPOLES 3.8 PARKING STRUCTURES 3.9 HELICOPTER PADS 3.10 WATER TANKS 3.11 ROOF-MOUNTED ANTENNA-OBSTRUCTION LIGHTS CHAPTER 4: PATIENT AREAS LIGHTING GUIDELINES 4.1. PATIENT AREAS LIGHTING GUIDELINES MATRIX 4.2 SPECIALTY, DIAGNOSTIC, AND TREATMENT AREAS 4.2.1 EXAMINATION AND TREATMENT ROOM 4.2.2 BLOOD DRAW STATION 4.2.3 ORTHOTIC
    [Show full text]
  • Are Those Inexpensive Incandescent Black Lights Any Good?
    HauntMaven.com - Wolfstone's Haunted Halloween Site http://wolfstone.halloweenhost.com/Lighting/bltgen_BlackLightGeneration.html Generating and Projecting Black Light You wouldn't think that there is so much to say about black light lamps. But we decided that the subject deserves a page of its own. So, where can I get cheap black lights? When the psychedelic era sputtered and died out, it took Lava Lamps and fuzzy black light posters with it. There is enough of a retro movement that these things can still be found ‐ retro lives at Spencer Gifts. Better still, many stores offer black lights when Halloween rolls around. The best black light for all-around haunt use is a fluorescent black light. These resemble the regular white fluorescent lights, found in offices and stores, except that they use a special lamp that emits black light. The lamps used for black light effects have several modifications from the standard white fluorescent Obtained lamps: from • there is usually Omarshauntedtrail.commore mercury, for enhanced UV generation • the phosphors are designed to convert short wave UV into long wave UV • the glass envelope is made from a purple filter glass, which prevents the emission of visible light Such fluorescent black light fixtures, complete with lamp, ready to turn on, are available at Spencer Gifts and other stores. These small fluorescent units are intended to light up posters and other decorations. They work fine on spooky stuff, too. You can make your own black light setup with a shop-light fluorescent fixture and pair of 4-foor black light lamps from Home Depot - total cost around $30, and it puts out much more light than units intended for posters.
    [Show full text]
  • Installation, Usage, & Care Guide
    Model No. PWRW50-PC-4K-WH Mfr. SKU 103-01100005-1 POWERWALL LED WALLPACK INSTALLATION, USAGE, & CARE GUIDE Questions? / Missing Parts? / Need Accessories? Before returning to the store, call or email PROBRITE Customer Service 9am-5pm EST Monday to Friday. 1-844-507-5651 [email protected] PROBRITE.COM Visit us online anytime or call us to get information on our product range, download detailed spec & photometric files, find product and mounting accessories, view installation tutorials and videos, and learn about our DLC® rebate eligible products. Table of Contents Pre-Installation Table of Contents......................... 2 Package Contents......................... 4 PLANNING INSTALLATION Safety Information....................... 2 Installation.................................... 5 Before installing the light fixture, ensure that all parts are present. Compare parts with the Pre-Installation.............................. 3 Operation...................................... 9 Hardware Included and Package Contents sections. If any part is missing or damaged, do Planning Installation...................... 3 Care & Cleaning.......................... 10 not attempt to assemble, install, or operate this light fixture. Specifications.................................. 3 Troubleshooting.......................... 10 Tools Required................................. 3 Warranty....................................... 11 Estimated installation time: 20 minutes Hardware Included......................... 4 SPECIFICATIONS Safety Information Lumens (Light
    [Show full text]
  • Lighting Design Concept and Development of Spring Awakening by Frank Wedekind
    Lighting Design Concept and Development of Spring Awakening By Frank Wedekind A Thesis Presented in Partial Fulfillment of the Requirements for the Degree Master of Fine Arts in the Graduate School of The Ohio State University By Alex Kyle-DiPietropaolo Graduate Program in Theatre The Ohio State University 2011 Thesis Committee: Professor Mary Tarantino, Advisor Assistant Professor Jimmy Bohr Assistant Professor Janet Parrott Copyright by Alex Kyle-DiPietropaolo 2011 Abstract This thesis documents the design process for the production Spring Awakening by Frank Wedekind, as translated by Jonathan Franzen. The show was produced in The Ohio State University‟s Thurber Theatre from February 24th through March 13th, 2011. The design concepts for the production were developed as informed by an adolescent‟s perspective on the world, and the representation of that viewpoint through lighting design. Modern theatre techniques were employed to address issues raised in the play. One such modern technique was the use of live video to reinforce the emotional impact in key scenes, which required researching lighting design for the medium of film, and how to adapt it to the stage. Working within these design ideas, color and the positions of instruments were used to develop a hyper-reality where the adolescents‟ emotions and feelings are echoed in the world around them. ii Dedication This document is dedicated to those people who never let me get away with mediocrity. iii Acknowledgments First, I would like to acknowledge my parents. They accepted my floating through reality after reality, and only momentarily balked at my choice to make a career in theatre.
    [Show full text]