Installation, Usage, & Care Guide
Total Page:16
File Type:pdf, Size:1020Kb
Model No. PWRW50-PC-4K-WH Mfr. SKU 103-01100005-1 POWERWALL LED WALLPACK INSTALLATION, USAGE, & CARE GUIDE Questions? / Missing Parts? / Need Accessories? Before returning to the store, call or email PROBRITE Customer Service 9am-5pm EST Monday to Friday. 1-844-507-5651 [email protected] PROBRITE.COM Visit us online anytime or call us to get information on our product range, download detailed spec & photometric files, find product and mounting accessories, view installation tutorials and videos, and learn about our DLC® rebate eligible products. Table of Contents Pre-Installation Table of Contents......................... 2 Package Contents......................... 4 PLANNING INSTALLATION Safety Information....................... 2 Installation.................................... 5 Before installing the light fixture, ensure that all parts are present. Compare parts with the Pre-Installation.............................. 3 Operation...................................... 9 Hardware Included and Package Contents sections. If any part is missing or damaged, do Planning Installation...................... 3 Care & Cleaning.......................... 10 not attempt to assemble, install, or operate this light fixture. Specifications.................................. 3 Troubleshooting.......................... 10 Tools Required................................. 3 Warranty....................................... 11 Estimated installation time: 20 minutes Hardware Included......................... 4 SPECIFICATIONS Safety Information Lumens (Light Output) 6800 Lumens Watts (Power Consumption) 50 Watts LED IMPORTANT Replaces 175 Watt Metal Halide THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE Lumens/Watts (Efficacy) 136 NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS Power Requirements 120-277VAC INVOLVED. (Input Voltage) Light Color (CCT) 4000 Kelvins (Bright White) PRECAUTIONS Dimmable WARNING: Turn the power off at the circuit Dimming (Use with 0-10V dimming switch) ☐ Please read and understand this entire breaker or fuse. Place tape over the circuit Operating Modes Dusk-to-Dawn: manual before attempting to assemble, breaker switch and verify power is off at the Automatically turns light fixture ON during night install, or operate this light fixture. light fixture. and OFF during day. ☐ This light fixture requires a 120-277 Volt AC power source. WARNING: Risk of fire. Keep the lamp heads Switch-Controlled: at least 3 in. (76mm) from combustible Flip switch to turn light fixture ON and OFF. Use ☐ Some codes require installation by a materials. included light sensor cap on fixture's light sensor qualified electrician. to utilize this mode setting. ☐ This light fixture must be properly CAUTION: Burn hazard. Allow the light fixture grounded. to cool before touching. TOOLS REQUIRED ☐ Make sure connections are secure using wire nuts, crimp-on lugs or other approved connecting devices NOTICE: For dimming use a 0-10V dimming Phillips switch Wire strippers/ Circuit tester ☐ This light fixture should be installed Screwdriver outdoors to the wall. cutters ☐ This product may contain chemicals NOTICE: FCC Regulations state that any known to be hazardous. Thoroughly unauthorized changes or modifications to this equipment not expressly approved wash hands after installing, handling, by the manufacturer could void the user’s cleaning or otherwise touching the authorization to operate this equipment. Silicone Ladder product. Work Sealant gloves INFORMATION: The device is tested and found to comply with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) This device may not cause harmful interference and, (2) this device must accept any interference received, including any interference that may cause undesired operation. Safety Flat head These limits are designed to provide reasonable protections against harmful interference when the equip- hammer ment is operated in a commercial environment. goggles 2 3 PROBRITE.COM Visit www.probrite.com/install for installation video tutorials and product support Please call 1-844-507-5651 or email [email protected] for further assistance. Pre-Installation (continued) Installation HARDWARE KIT For best results NOTE: Hardware not shown to actual size. 1 ☐ The fixture can be mounted in the following two ways: AA BB CC ☐ Junction Box Mount: Use a junction box to mount the fixture. ☐ Surface Conduit Mount: The fixture can also be mounted directly on the wall surface using conduit entry. ☐ When mounting fixture, for Dusk Wall Mount to Dawn operation, make sure the Part Description Quantity photocell orientation is at the top for wall mount, in an area that receives AA #8-32 x 3/4" philips mounting bracket screw 2 daylight and not too close to reflective BB Wire nut 3 surfaces. CC Photocell clear cap cover 1 ☐ When installing two fixtures on one switch, make sure the switch is rated for at least a 1A inductive load. PACKAGE CONTENTS ☐ If dimming, use with 0-10V dimming F switch. 1-1/2" 1-1/2" D E NOTE: Mounting base (D) mounts to recessed mounted standard junction boxes or to the sur- (fig 1). face directly. Junction box must be at least 1-1/2 inch in depth for proper installation for recessed Round Octagonal/Square mount application (fig 1). A B C Shut electric power off Part Description Quantity 2 A Light fixture 1 ☐ At wall switch verify it is in the off position (fig 1). B Conduit entry plug 5 (fig 1). (fig 2). ☐ At the main electrical panel turn off C Mounting base tightening screw (pre-installed) 2 the circuit breaker that supplies power D Mounting base 1 to the outlet box you are working on (fig 2). E Photocell opaque cap cover 1 For screw-in type fuses unscrew the F Photocell black opaque cap cover 1 ☐ fuse that supplies power to the outlet box you are working on (fig 3). (fig 3). 4 5 PROBRITE.COM Visit www.probrite.com/install for installation video tutorials and product support Please call 1-844-507-5651 or email [email protected] for further assistance. Installation (continued) Installation (continued) Remove the Installing the mounting base Junction Box 3 mounting base plate 5 D Junction Box NOTE: The mounting plate tightening screws (C) comes pre-installed on the light fixture. ☐ Route the junction box wires through the large center hole in the mounting C base (D). ☐ Loosen the two mounting base D tightening screws (C) using a philips ☐ Align the holes on the mounting screwdriver to open the fixture. (Fig. 1) base (D) with the holes on your junction box. Use two #8 screws (AA), The fixture will side open and stay (fig 1). ☐ depending on the size of the holes in connected on the hinge.( Fig. 2) your junction box, attach the mounting AA base (D) to your junction box. (Fig. 1) CAUTION: DO NOT touch the LED and (fig 1). Photocell lens (E) inside the fixture. DO NOT damage or soil the reflector. Surface Conduit Mount (fig 2). ☐ Mark and drill two to four holes on the wall surface as per the desired location for fixing the mounting plate (D). Knock out holes on ☐ Use two or more suitable screws 4 mounting base (provided by others) applicable to the surface of mounting and fix the D mounting plate (D) on the surface. ☐ For junction box mount: Measure the (Fig. 2) size of your junction box and refer to the guide in Fig. 1 to select the holes Screws (Provided by others) to knock out. (fig 2). ☐ For 31/4" junction box- Knock out two holes in the inner ring. ☐ For 4" junction box- Knock out two holes on the outer ring. Making the electrical ☐ For surface mount: Measure the 6 distance between two holes, pre- connections drill holes into the mounting surface, (fig 1) and knock holes on the desired ring Junction Box BB accordingly. ☐ Follow the wiring instructions given below to make the electrical connec- ☐ Use a flat head hammer and screw driver to knock out the two holes. tions. (Fig. 1) (fig 1). 6 7 PROBRITE.COM Visit www.probrite.com/install for installation video tutorials and product support Please call 1-844-507-5651 or email [email protected] for further assistance. Installation (continued) Installation (continued) Securing the light fixture on the mounting Surface Conduit Mount 7 base and caulking D ☐ Remove desired conduit plug from one of the fixture's sides from the where ☐ Close the fixture by tightening the two D conduit will enter. (Fig. 2) mounting base tightening screws (C), using a philips screwdriver, which were ☐ Make wiring connections inside the removed earlier in Step 1. (Fig. 1) fixture as per the instructions given BB Conduit below. ☐ Caulk around the mounting plate (D) and surface with silicone sealant (not C ☐ If necessary, strip 3/8" of insulation (fig 2). included).(Fig. 1) from junction box or fixture (A) wires (fig 1). (fig 1). NOTICE: Failure to properly caulk around the NOTE: When attaching this fixture (A) to an ON/OFF Wiring (Non Dimming) Method: surface and mounting plate (D) could lead external surface mount junction box, caulk the (fig 3). to water damage and is not covered under inside of the light fixture before attaching to the ☐ Connect fixture black wire to house warranty. mounting plate (D). black wire, the (+) line, and fixture white wire to house white wire, the (-) common by twisting the exposed wires together and using the wire nuts (BB). (+) LINE BLACK Ensure no loose wires. Operation (-) COMMON WHITE LIGHTING ☐ Connect house ground wire to the FIXTURE green fixture ground wire, by twisting Selecting Dusk-to-Dawn or GROUND GREEN AUTOMATIC the exposed wires together and using 1 Switch-Controlled NIGHTTIME ON the wire nuts (BB). (Non-Dimming Wiring Diagram) OPTION 1: DUSK-TO-DAWN OPERATION 0-10V Dimmable Wiring Method: (+) LINE BLACK Dusk-to-dawn operation enables the light fixture to automatically turn ☐ Connect fixture black wire to house ON when dark outside and turn OFF when the sun rises, thus saving you DAYTIME OFF black wire, the (+) line, and fixture (-) COMMON WHITE energy. Swap white wire to house white wire, the (-) (+)DIM V+ PURPLE CC common by twisting the exposed wires LIGHTING ☐ To enable dusk-to-dawn remove the F together and using the wire nuts (BB).