UFC 3-410-02 Direct Digital Control for HVAC and Other Building

Total Page:16

File Type:pdf, Size:1020Kb

UFC 3-410-02 Direct Digital Control for HVAC and Other Building UFC 3-410-02 18 July 2018 Change 2, 12 April 2021 UNIFIED FACILITIES CRITERIA (UFC) DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING CONTROL SYSTEMS APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED 1 UFC 3-410-02 18 July 2018 Change 2, 12 April 2021 UNIFIED FACILITIES CRITERIA (UFC) DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING CONTROL SYSTEMS Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. Indicate the preparing activity beside the Service responsible for preparing the document. U.S. ARMY CORPS OF ENGINEERS \1\ (Preparing Activity) /1/ NAVAL FACILITIES ENGINEERING COMMAND \1\ /1/ AIR FORCE CIVIL ENGINEER CENTER Record of Changes (changes are indicated by \1\ ... /1/) Change No. Date Location 1 2 March 2020 Changed Preparing Activity from Navy to Army. Added paragraph 2-4 USE OF PROPRIETARY NETWORKS, to accommodate new requirements for an exception to the use of open protocols within specific system types when certain criteria are met. 2 1 April 2021 Changed “UFC 3-401-01” to UFC 3-470-01” in paragraphs 1-2.1.3 and 1-3.2.3. Changed “APPENDIX A” to “APPENDIX D” in paragraph 5-4.2. Deleted first sentence of paragraph 6-6.1. This UFC supersedes UFC 3-410-02, dated 5 2012. 2 UFC 3-410-02 18 July 2018 Change 2, 12 April 2021 FOREWORD The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD (AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other customers where appropriate. All construction outside of the United States is also governed by Status of Forces Agreements (SOFA), Host Nation Funded Construction Agreements (HNFA), and in some instances, Bilateral Infrastructure Agreements (BIA.) Therefore, the acquisition team must ensure compliance with the most stringent of the UFC, the SOFA, the HNFA, and the BIA, as applicable. UFC are living documents and will be periodically reviewed, updated, and made available to users as part of the Services’ responsibility for providing technical criteria for military construction. Headquarters, U.S. Army Corps of Engineers (HQUSACE), Naval Facilities Engineering Command (NAVFAC), and Air Force Civil Engineer Center (AFCEC) are responsible for administration of the UFC system. Defense agencies should contact the preparing service for document interpretation and improvements. Technical content of UFC is the responsibility of the cognizant DoD working group. Recommended changes with supporting rationale should be sent to the respective service proponent office by the following electronic form: Criteria Change Request. The form is also accessible from the Internet sites listed below. UFC are effective upon issuance and are distributed only in electronic media from the following source: • Whole Building Design Guide web site http://dod.wbdg.org/. Refer to UFC 1-200-01, DoD Building Code (General Building Requirements), for implementation of new issuances on projects. AUTHORIZED BY: ______________________________________ ______________________________________ LARRY D. McCALLISTER, P.E., PhD, PMP, SES JOSEPH E. GOTT, P.E. Chief, Engineering and Construction Chief Engineer Directorate of Civil Works Naval Facilities Engineering Command U.S. Army Corps of Engineers ______________________________________ ______________________________________ EDWIN H. OSHIBA, SES, DAF MICHAEL McANDREW Deputy Director of Civil Engineers Deputy Assistant Secretary of Defense DCS/Logistics, Engineering & Force Protection (Facility Investment & Management) Office of the Assistant Secretary of Defense (Energy, Installations, and Environment) 3 UFC 3-410-02 18 July 2018 Change 2, 12 April 2021 UNIFIED FACILITIES CRITERIA (UFC) REVISION SUMMARY SHEET Document: UFC 3-410-02 Direct Digital Control for HVAC and Building Control Systems, formerly LonWorks® Direct Digital Control for HVAC and Other Local Building Systems Superseding: None Description: Design guidance and requirements for Open Direct Digital Control Systems. The guidance is particularly detailed due to the complex and definitive requirements required for the design of a digital control system and for the procurement of an Open system that supports integration into a multi-vendor system. Reasons for Document: Initial version of this UFC covered LNS-Based LonWorks only. Extensive revisions were required to accommodate BACnet and the Niagara Framework. Impact: There are negligible cost impacts; however, these benefits should be realized: • The ability to procure systems competitively that can be integrated into a single supervisory system rather than requiring the procurement of several supervisory systems. • Competitive procurement of control systems will result in cost savings. Describe the impact. This should describe impact on design cost, initial cost, energy savings, or life cycle costs. Unification Issues: None 4 UFC 3-410-02 18 July 2018 Change 2, 12 April 2021 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION ............................................................................................ 1 1-1 BACKGROUND. ............................................................................................ 1 1-1.1 Open system benefits and capabilities. .................................................... 1 1-1.2 References to UFGS 23 09 23.XX. ........................................................... 2 1-2 OPEN SYSTEM TECHNOLOGIES. ............................................................. 2 1-2.2 Control system types ................................................................................. 3 1-2.3 Open system design complexity ............................................................... 3 1-3 PURPOSE AND SCOPE. .............................................................................. 4 1-3.1 Purpose ...................................................................................................... 4 1-3.2 Scope.......................................................................................................... 4 1-4 APPLICABILITY. ........................................................................................... 5 1-5 GENERAL BUILDING REQUIREMENTS. ................................................... 5 1-6 REFERENCES. .............................................................................................. 5 1-7 GLOSSARY.................................................................................................... 5 CHAPTER 2 TECHNICAL REQUIREMENTS .................................................................... 7 2-1 USE OF UFGS 23 09 XX SERIES OF SPECIFICATIONS. ........................ 7 2-2 USE OF UFGS 23 09 23.XX. ........................................................................ 7 2-3 TAILORING AND DESIGNER OPTIONS IN UFGS 23 09 23.XX. ............. 7 2-4 \1\ USE OF PROPRIETARY NETWORKS. /1/ ............................................ 7 2-4.1 \1\ Proprietary Networks for Simple Split Systems. /1/ ............................ 7 2-4.2 \1\ Proprietary Networks for Multi-Split Systems (Including Variable Refrigerant Flow (VRF) Systems). /1/ ............................................................................. 8 2-4.3 \1\ Proprietary Networks for Chiller and Boiler Plants. /1/ ....................... 8 2-4.4 \1\ All Other Systems. /1/ ........................................................................... 9 CHAPTER 3 DESIGN ........................................................................................................ 11 3-1 INTRODUCTION. ......................................................................................... 11 3-2 BASEWIDE UMCS ARCHITECTURE........................................................ 11 3-3 LONWORKS BCN ARCHITECTURE. ....................................................... 12 3-3.1 General. .................................................................................................... 12 3-3.2 CEA 709 Media selection. ....................................................................... 14 3-4 BACNET BCN ARCHITECTURE. .............................................................. 14 v UFC 3-410-02 18 July 2018 Change 2, 12 April 2021 3-4.1 Device and network addressing. ............................................................. 15 3-4.2 Media selection. ....................................................................................... 16 3-5 NIAGARA FRAMEWORK NETWORK. ..................................................... 17 3-5.1 Niagara Framework and LonWorks. ....................................................... 17 3-5.2 Niagara Framework and BACnet. ........................................................... 18 3-6 CONNECTION TO A UMCS. ...................................................................... 18 3-7 NETWORK HARDWARE. ........................................................................... 18 3-8 NETWORK DESIGN AND LAYOUT. ......................................................... 19 3-8.1 Data transmission methods. .................................................................... 19 3-8.2 Data integrity. ........................................................................................... 19 3-8.3 Number of controllers per system or sequence. .................................... 20 3-9 CYBERSECURITY.
Recommended publications
  • Supervisory Control and Data Acquisition (Scada)
    TM 5-601 TECHNICAL MANUAL SUPERVISORY CONTROL AND DATA ACQUISITION (SCADA) SYSTEMS FOR COMMAND, CONTROL, COMMUNICATIONS, COMPUTER, INTELLIGENCE, SURVEILLANCE, AND RECONNAISSANCE (C4ISR) FACILITIES APPROVED FOR PUBLIC RELEASE: DISTRIBUTION UNLIMITED HEADQUARTERS, DEPARTMENT OF THE ARMY 21 JANUARY 2006 TM 5-601 REPRODUCTION AUTHORIZATION/RESTRICTIONS This manual has been prepared by or for the Government and, except to the extent indicated below, is public property and not subject to copyright. Reprint or republication of this manual should include a credit substantially as follows: "Department of the Army, TM 5-601, Supervisory Control and Data Acquisition (SCADA) Systems for Command, Control, Communications, Computer, Intelligence, Surveillance, and Reconnaissance (C4ISR) Facilities, 21 January 2006." Table 3-1 Safety integrity levels – low demand operation and table 3-2 Safety integrity levels – continuous operation are reprinted with permission from the International Electrotechnical Commission (IEC) publication International Standard IEC 61508-1, tables 2 and 3 from subclause 7.2.6.9. “The author thanks the IEC for permission to reproduce information from its International Standard IEC 61508-1: (1998). All such extracts are copyright of IEC, Geneva, Switzerland. All right reserved. Further information on the IEC is available from www.iec.ch. IEC has no responsibility for the placement and context in which the extracts and contents are reproduced by the author, nor is IEC in any way responsible for the other content or accuracy therein.” TM 5-601 Technical Manual HEADQUARTERS No. 5-601 DEPARTMENT OF THE ARMY Washington, DC, 21 January 2006 APPROVED FOR PUBLIC RELEASE: DISTRIBUTION IS UNLIMITED SUPERVISORY CONTROL AND DATA ACQUISITION (SCADA) SYSTEMS FOR COMMAND, CONTROL, COMMUNICATIONS, COMPUTER, INTELLIGENCE, SURVEILLANCE, AND RECONNAISSANCE (C4ISR) FACILITIES CONTENTS Paragraph Page CHAPTER 1.
    [Show full text]
  • MASTER SPECIFICATIONS Division 25 – INTEGRATED AUTOMATION
    MASTER SPECIFICATIONS Division 25 – INTEGRATED AUTOMATION AND HVAC CONTROL Release 1.0 [March] 2017 Released by: Northwestern University Facilities Management Operations 2020 Ridge Avenue, Suite 200 Evanston, IL 60208-4301 All information within this Document is considered CONFIDENTIAL and PROPRIETARY. By receipt and use of this Document, the recipient agrees not to divulge any of the information herein and attached hereto to persons other than those within the recipients’ organization that have specific need to know for the purposes of reviewing and referencing this information. Recipient also agrees not to use this information in any manner detrimental to the interests of Northwestern University. Northwestern University Master Specifications Copyright © 2017 By Northwestern University These Specifications, or parts thereof, may not be reproduced in any form without the permission of the Northwestern University. NORTHWESTERN UNIVERSITY PROJECT NAME ____________ FOR: ___________ JOB # ________ ISSUED: 03/29/2017 MASTER SPECIFICATIONS: DIVISION 25 – INTEGRATED AUTOMATION AND HVAC CONTROL SECTION # TITLE 25 0000 INTEGRATED AUTOMATION AND HVAC TEMPERATURE CONTROL 25 0800 COMMISSIONING OF INTEGRATED AUTOMATION ** End of List ** NORTHWESTERN UNIVERSITY PROJECT NAME ____________ FOR: ___________ JOB # ________ ISSUED: 03/29/2017 SECTION 25 0000 - INTEGRATED AUTOMATION AND HVAC TEMPERATURE CONTROL PART 1 - GENERAL 1.1 SUMMARY AND RESPONSIBILITIES A. The work covered under this Division 25 of the project specifications is basically for: 1. Providing fully functioning facility/project HVAC system DDC controls. 2. Controlling systems locally, with communication up to the Tridium integration platform for remote monitoring, trending, control, troubleshooting and adjustment by NU Engineering and Maintenance personnel. 3. Tying specified systems to the Northwestern University (NU) integration platform for remote monitoring, trending, control, management, troubleshooting and adjustment by NU Engineering and Maintenance personnel.
    [Show full text]
  • STANDARD Building Management Systems
    STANDARD Building Management Systems Original Issue: January 22, 2008 Last Update: August 24, 2020 PAGE INTENTIONALLY LEFT BLANK E&M Standard: Building Management Systems TABLE OF CONTENTS 1. PURPOSE AND INTENT 1 2. APPROVED MANUFACTURERS 1 3. GENERAL REQUIREMENTS 1 4. EXISTING SYSTEMS 2 5. DIRECT DIGITAL CONTROL SYSTEM 2 6. SYSTEM ARCHITECTURE 2 7. OPERATING ENVIRONMENT 3 8. DIRECT DIGITAL CONTROL UNITS 3 9. COMPUTERS, HANDHELDS AND ACCESS DEVICES 4 10. SYSTEM COMMUNICATIONS 4 11. NETWORK COMPUTER SOFTWARE 4 12. GRAPHICS 4 13. LABORATORY FLOW CONTROL SYSTEM (WITH OR WITHOUT FUME HOODS) 6 14. INSTRUMENTATION 6 15. AUTOMATIC CONTROL VALVES 9 16. AUTOMATIC CONTROL AND AUTOMATIC SMOKE DAMPERS 9 17. POWER REQUIREMENTS 10 18. DESCRIPTION OF CONTROL OPERATION 10 19. INSTALLATION REQUIREMENTS 11 20. TESTING, CALIBRATION AND COMMISSIONING 12 21. INSTRUCTION OF OPERATING PERSONNEL 13 22. SERVICING AND MAINTENANCE REQUIREMENTS 13 APPENDIX 1: EQUIPMENT IDENTIFICATION AND BMS POINT NAMES 1 APPENDIX 2: SAMPLE GRAPHICS 1 APPENDIX 3: STANDARD BMS POINT LISTS 1 E&M STANDARD: BUILDING MANAGEMENT SYSTEMS 1. PURPOSE AND INTENT 1.1 This document provides both general and specific requirements for the installation and modification of Building Management Systems at Weill Cornell Medicine. It should be used when building or renovating any WCM space. 2. APPROVED MANUFACTURERS 2.1 The following manufacturers are approved for providing BMS Systems within WCM space: a. Automated Logic Controls b. Schneider Controls (formerly Andover) c. Siemens Building Technologies Note: Siemens Desigo Platform only. Apogee Platform is no longer accepted. 2.2 Where specific manufacturers or products are specified herein, substitutions are not allowed unless specifically approved for a specific project by WCM’s Department of Engineering and Maintenance.
    [Show full text]
  • Section 230923
    NORTHWESTERN UNIVERSITY PROJECT NAME ____________ FOR: ___________ JOB # ________ ISSUED: 03/29/2017 SECTION 25 0000 - INTEGRATED AUTOMATION AND HVAC TEMPERATURE CONTROL PART 1 - GENERAL 1.1 SUMMARY AND RESPONSIBILITIES A. The work covered under this Division 25 of the project specifications is basically for: 1. Providing fully functioning facility/project HVAC system DDC controls. 2. Controlling systems locally, with communication up to the Tridium integration platform for remote monitoring, trending, control, troubleshooting and adjustment by NU Engineering and Maintenance personnel. 3. Tying specified systems to the Northwestern University (NU) integration platform for remote monitoring, trending, control, management, troubleshooting and adjustment by NU Engineering and Maintenance personnel. 4. The Division 25 controls contractor to (subcontractor to the GC and also referred to herein as the DDC/BASC Contractor) provide a complete DDC Control and Building Automation system, which interfaces with the NU Tridium Integration platform through the University’s Ethernet infrastructure.. The Owners' normal day to day interface will be with the Tridium system. The configuration of graphics, trends, alarms, etc. for the Tridium system will be done by the System Integrator. [For this project, the System Integrator is to be hired by the University/General Contractor/Commissioning Authority, as determined during project design and finalized herein this section by the project AE. See Section 1.4]. The Division 25 Contractor is responsible for coordinating with the System Integrator to verify all points are properly integrated into the Tridium platform including alarm values and links to trend files. The Division 25 contractor is to provide sufficient manpower to work with the System Integrator to do a point to point test of alarms, trending, setpoint overrides, etc.
    [Show full text]
  • PLC & Fieldbus Control Systems Automation Guidebook – Part 4
    PDHonline Course E448 (9 PDH) ______________________________________________________________________________ PLC & Fieldbus Control Systems Automation Guidebook – Part 4 Instructor: Jurandir Primo, PE 2014 PDH Online | PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.PDHonline.org www.PDHcenter.com An Approved Continuing Education Provider www.PDHcenter.com PDHonline Course E448 www.PDHonline.org PLC & FIELDBUS CONTROL SYSTEMS AUTOMATION GUIDEBOOK – PART 4 CONTENTS: 1. PLC HISTORY 2. INTRODUCTION 3. INPUT/OUTPUT (I/O) CAPABILITIES 4. LADDER LOGIC PROGRAMS 5. HUMAN-MACHINE INTERFACE (HMI) 6. HOW THE PLCs WORK 7. FIELDBUS CONTROL SYSTEMS 8. DCS AND FIELDBUS DEVELOPMENT 9. FIELDBUS MODELS AND NETWORK STRUCTURE 10. DIAGNOSTICS & COMMUNICATION INTERFACES 11. BASIC COMMUNICATION STANDARDS 12. REFERENCES & LINKS ©2014 Jurandir Primo Page 1 of 101 www.PDHcenter.com PDHonline Course E448 www.PDHonline.org 1. PLC HISTORY The early history of the PLC (Programmable Logic Controller) goes back to the 1960’s when control systems were still handled using relay control. During this time the control rooms consisted of sev- eral walls containing many relays, terminal blocks and mass of wires. In 1968 Bill Stone, who was part of a group of engineers at the Hydramatic Division of General Mo- tors Corporation, presented a paper at the Westinghouse Conference outlining their problems with reliability and documentation for the machines at this plant. He also presented a design criteria de- veloped by the GM engineers for a “standard machine controller”, to eliminate costly scrapping of assembly-line relays. These specifications along with a proposal request to build a prototype were given to four control builders: • Allen-Bradley, by way of Michigan-based Information Instruments, Inc.
    [Show full text]
  • Lighting Answers: Controlling Lighting with Building Automation Systems
    Answers Controlling Lighting with Building Automation Systems . Volume 4 Number 1 May 1997 Introduction • The ability to monitor and control lighting throughout a building or even throughout The potential for substantial energy savings a multi-building facility has made the use of automated lighting • The ability to minimize peak demand, controls such as timers, occupancy sensors, thereby reducing energy costs where and photosensors commonplace in modern utility rate structures are based on peak buildings. Similarly, building automation demand and real-time pricing systems that control heating, ventilation, and air-conditioning (HVAC) have become com- Conventional lighting control systems mon in new construction and are now in- often control equipment in a single room or cluded as part of many retrofit projects; more over a limited area, because they are cen- than half the large commercial buildings tralized control systems, which means that all (averaging 200,000 sq ft) surveyed by the the controlled circuits must be wired to a Wisconsin Center for Demand-Side Research single control panel. The computers used (WCDSR 1995) included a building automa- by these systems are typically dedicated tion system. microprocessors that perform only lighting Building automation systems can also control functions. be used to control lighting; however, high By comparison, modern building automa- initial and maintenance costs, the apparent tion systems are distributed control systems, complexity of these systems, and concerns which means that their computing hardware about the interoperability* of lighting sys- and software are distributed as a network tems and other building systems have lim- that comprises microprocessor-based control ited such applications.
    [Show full text]
  • Bacnet Building Automation System Direct Digital Controls Guide Specification
    University of Houston Master Construction Specifications Insert Project Name BACNET BUILDING AUTOMATION SYSTEM DIRECT DIGITAL CONTROLS GUIDE SPECIFICATION CONTENTS SECTION HEADERS ARE HOT‐LINKABLE. CTRL + CLICK TO FOLLOW HYPERLINKS PART 1 ‐ GENERAL 1.1 System Description 1.2 Work Included 1.3 System Requirements 1.4 Basic System Architecture 1.5 Material Furnished Under This Section But Installed Under Other Sections 1.6 Related Sections 1.7 Quality Assurance 1.8 System Performance 1.9 Submittals 1.10 Calibration, Commissioning, Demonstration & Acceptance 1.11 Training 1.12 Warranty, Maintenance, Normal & Emergency Service PART2 ‐ PRODUCTS 2.1 Acceptable Manufacturers 2.2 Web Server Hardware 2.3 Web Enabled Application Software 2.4 Operators Workstation Platform (B‐OWS) 2.5 Control System Operators Workstation Application Software (B‐OWS) 2.6 Service Tools 2.7 BACnet Protocol Verification Software 2.8 Building Controllers (B‐BC) 2.9 Advanced Application Controllers (B‐AAC) 2.10 Space Mounted/Local Display Advanced Application Controllers (B‐AAC) 2.11 Application Specific Controllers (B‐ASC) 2.12 Networked Communicating Smart Space Sensors 2.13 Temperature Control Panels (TCP), Enclosures & Sub‐Panels 2.14 Interconnecting Wire & Cable 2.15 Field Devices 2.16 Analog Sensors 2.17 Switching Sensors & Thermostats 2.18 Automatic Control Valves 2.19 Automatic Control Valve Actuators 2.20 Automatic Control Dampers 2.21 Automatic Control Damper Actuators AE Project Number: Building Control and Automation (BCAS) 23 06 00 – 1 Revision Date: 1/29/2014
    [Show full text]
  • DDC/BMS/EMS & Integration Back to Basics
    7/08/2012 Back to Basics – DDC/BMS/EMS & Integration Back to Basics – DDC/BMS/EMS & Integration Presented by: The views and opinions expressed in this presentation are from my experiences in Thomas McIlhatton, Distributor Manager the industryyy over 20 years. These are not explicit views of Innotech directly and may differ between people and manufacturers. Innotech Control Systems Australia Airah, 11th July 2012 Agenda • Terminology • Direct Digital Controls (DDC) • Building Management Systems (BMS) • Energy Management Systems (EMS) • Proprietary Systems • Interoperable Systems • Misinterpretations of “Open Technology” • Looking after the Clients best interests (Initially and ongoing) • Engineering Practices and Serviceability • Integration Demonstration with multiple vendors 1 7/08/2012 System Terminology System Terminology • DDC System - Direct Digital Control System • Bus – The physical communications platform used for inter-device communications and connection to the BMS computer. This does not define the • BMS - Building Management System protocol used. Types of Bus include: • RS485 communications – Over specific cable • EMS - Energy Management System • Ethernet – Over a computer Network • I/O - Inputs/Outputs • Proprietary - A defined protocol that is unique to an individual or company. The raw code is not in the public domain • Hardware - Physical devices used to make decisions for controlled outputs, based on changgpes in input conditions • Oppgyen Technology - A solution based on uniformityypy and interoperability. A philosophy used to ensure competitive pricing and client focussed benefits • HMI – Human Machine Interface (A controller or network display) • Integration - The process of translating from one protocol to another • Software - The computer interface for the hardware, or separate utilities to perform value-added tasks • Interoperability - The ability to integrate with other vendors equipment • HLI- High Level Interface.
    [Show full text]
  • Green Building & Controls Glossary
    GREEN BUILDING & CONTROLS GLOSSARY kmccontrols.com Read First: Top Tips on Using this Glossary These tips are for optimizing your use of the Adobe Acrobat PDF version of this document. For the fastest finding of terms, click on the appropriate bookmarks and/or cross-references. Alternately, use Acro- bat’s search function to look up terms. Bookmarks, at the left of the screen, are hyperlinks to document pages. From any page in this document, you can use book- marks to jump to any section heading. To jump to a bookmarked section, point to the bookmark name, and when the arrow be- comes a pointing hand, click on the name. Cross-references (in blue italics) at the end of glossary entries are hyperlinked to those topics. Click on the cross-reference to go instantly to that page. If printing pages, select from the print dialog box (Acrobat 7 and later) Page scal- ing > Multiple pages per sheet, Pages per sheet > 4. (Auto-Rotate Pages should also be checked.) This minimizes the number of sheets printed, and it still prints at nearly full size. (A commercially printed booklet version can also be ordered from KMC Controls.) 2 Green Building & Controls Glossary 19476 Industrial Drive New Paris, IN 46553, U.S.A. 877.444.5622 (574.831.5250) www.kmccontrols.com [email protected] KMC Controls,® KMDigital,® CommTalk,® ControlSet ®, Incontrol,® NetView,® NetSensor,® WinControl,® and “building your comfort zone®” are all registered trademarks of KMC Controls. KMC Conquest,™ KMC Commander,™ KMC CommanderBX™, KMC Con- nect,™ KMC Connect Lite,™ KMC Converge,™ FlexStat,™ TotalCon- trol,™ WebLite,™ LANLite,™ FirstWatch,™ BACstage,™ FullBAC,™ and BUILDING GENIUSES™ are all trademarks of KMC Controls.
    [Show full text]
  • TM 5-601 Supervisory Control and Data Acquisition (Scada)
    TM 5-601 TECHNICAL MANUAL SUPERVISORY CONTROL AND DATA ACQUISITION (SCADA) SYSTEMS FOR COMMAND, CONTROL, COMMUNICATIONS, COMPUTER, INTELLIGENCE, SURVEILLANCE, AND RECONNAISSANCE (C4ISR) FACILITIES APPROVED FOR PUBLIC RELEASE: DISTRIBUTION UNLIMITED HEADQUARTERS, DEPARTMENT OF THE ARMY 21 JANUARY 2006 TM 5-601 REPRODUCTION AUTHORIZATION/RESTRICTIONS This manual has been prepared by or for the Government and, except to the extent indicated below, is public property and not subject to copyright. Reprint or republication of this manual should include a credit substantially as follows: "Department of the Army, TM 5-601, Supervisory Control and Data Acquisition (SCADA) Systems for Command, Control, Communications, Computer, Intelligence, Surveillance, and Reconnaissance (C4ISR) Facilities, 21 January 2006." Table 3-1 Safety integrity levels – low demand operation and table 3-2 Safety integrity levels – continuous operation are reprinted with permission from the International Electrotechnical Commission (IEC) publication International Standard IEC 61508-1, tables 2 and 3 from subclause 7.2.6.9. “The author thanks the IEC for permission to reproduce information from its International Standard IEC 61508-1: (1998). All such extracts are copyright of IEC, Geneva, Switzerland. All right reserved. Further information on the IEC is available from www.iec.ch. IEC has no responsibility for the placement and context in which the extracts and contents are reproduced by the author, nor is IEC in any way responsible for the other content or accuracy therein.” TM 5-601 Technical Manual HEADQUARTERS No. 5-601 DEPARTMENT OF THE ARMY Washington, DC, 21 January 2006 APPROVED FOR PUBLIC RELEASE: DISTRIBUTION IS UNLIMITED SUPERVISORY CONTROL AND DATA ACQUISITION (SCADA) SYSTEMS FOR COMMAND, CONTROL, COMMUNICATIONS, COMPUTER, INTELLIGENCE, SURVEILLANCE, AND RECONNAISSANCE (C4ISR) FACILITIES CONTENTS Paragraph Page CHAPTER 1.
    [Show full text]
  • Programmable Logic Controllers and Direct Digital Controls in Buildings
    Programmable logic controllers and Direct digital controls in Buildings Item Type Article Authors Khalid, Yousaf Citation Khalid, Y. (2018). Programmable logic controllers and Direct digital controls in Buildings. Journal of Computing and Management Studies (JCMS), 2(3). Journal Journal of Computing and Management Studies Download date 30/09/2021 11:54:24 Item License http://creativecommons.org/licenses/by-nc-nd/4.0/ Link to Item http://hdl.handle.net/10034/621934 Programmable Logic Controllers and Direct Digital Controls in Buildings Khalid. Y Electronic and Electrical Engineering University of Chester, UK Email: [email protected] Abstract 2. Building Energy Management Systems (BEMS) The concept of programmable logic controller (PLC) originated over the last century that has BEMS is a high technology control system revolutionised the industrial sector. In the last few installed on buildings which performs the overall decades PLC in the form of DDC has been control and monitoring functions for some or all of commonly used in Building Energy Management the building's plant and systems (mechanical and Systems (BEMS). The contribution of this work is electrical equipment such as air handling, cooling to analyse PLC/DDC role in the ongoing BEMS plant systems, lighting and power systems etc.). advancements in the building sector. Currently DDC are not understood by building design and In modern buildings, BEMS is implemented as a simulation engineers who assess the controllability networked direct digital control system (shown of the building in practice. This paper would below) consisting of both software and hardware enhance the understanding of integrating DDC in (PLCs), display terminals with user interface for buildings and influence creation of better system scheduling and control.
    [Show full text]
  • WT-4000 Series Pneumatic-To-Direct Digital Control (DDC) Room Thermostats Installation Instructions Part No
    24- 10732- 5, Rev. D WT-4000 Series Pneumatic-to-Direct Digital Control (DDC) Room Thermostats Installation Instructions Part No. 24-10732-5, Rev. D Issued August 2017 WT-4002-MCR, WT-4002-MCM, WT-4002-MFR, WT-4002-MFM Refer to the QuickLIT website for the most up-to-date version of this document. Application All WT-4000 Series Room Thermostats include an LCD, with either a Fahrenheit or Celsius temperature The WT-4000 Series Pneumatic-to-Direct Digital display. Depending on the model chosen, the room Control (DDC) Room Thermostats provide reliable thermostat can transmit sensed temperature, setpoint zone comfort and enhanced energy economy via temperature, occupancy status, and low battery remote monitoring and temperature setpoint conditions to an associated router and gateway. The management. This arrangement provides greater WT-4000 Series Room Thermostat is designed for energy policy compliance, and facilitates trending of indoor, intra-building applications only. floor space usage in commercial, industrial, and municipal HVAC environments. The WT-4000 Series uses a proprietary direct-sequence, spread-spectrum RF technology, The WT-4000 Series Room Thermostats are ideally and operates on the 2.4 GHz Industrial, Scientific, and suited for energy-saving, pneumatic-to-DDC building Medical (ISM) band. The room thermostat meets the upgrades. Designed for non-invasive replacement IEEE 802.15.4 standard for low power, low duty cycle of existing manual pneumatic thermostats, the RF transmitting systems. WT-4000 Series Room Thermostats provide a number of DDC features, including remote wireless setpoint IMPORTANT: The WT-4000 Series control and occupancy scheduling, and continuous Pneumatic-to-DDC Room Thermostat is intended to room temperature, branch line pressure, and battery provide an input to equipment under normal status monitoring.
    [Show full text]