Application Note Clock Tower with PULS Power

Application Note AN50.01.en

Clock Tower with PULS Power Power Supplies for the Tower Author: Susanne Häfner

When night falls in Mecca the green dials of the world’s largest tower are still clearly visible at a distance of min. 10 miles. This is achieved with two million LEDs – and around 1000 power supplies.

© SL Rasch

The Royal Clock Tower in Mecca stands are bright green. The hands are black du- at a unique location in the immediate ring the day and brilliant white at night. vicinity of the most sacred site in all of Islam, the Kaaba. Its exterior dimensions The tower has been designed and tested are colossal, at 601 meters in height and to provide a service life of 100 years 120 stories it is the third tallest building during which it will have to withstand in the world – with a tower clock moun- extreme weather conditions and hurrica- ted at a height of above 400 m. ne-force wind.

The located at all four sides of the PULS has been entrusted with providing building are also exceptional; externally the power supplies. Approximately 1000 they appear similar to those of in units of the Dimension XT series, 48V / , but six as large. The edge 20A units deliver the one million Watts length of the clock dial is 43 m and the required to illuminate the LEDs. As a accessible minute hand measures 22m. result the power supplies form the core The display should be clearly legible of the electronic lighting system; if they at a long distance. During the daytime fail the clock faces remain dark. the clock dials are white, at night they

Technology page 1 / 3 www.pulspower.com Marketing The use of so many units in a very restric- Particularly sensitive components in a ted space with the requirement of com- switching power supply are the elect- paratively low heat development could rolytic capacitors (electrolytic). Depen- be achieved thanks to the high efficiency ding on their design they dry out over of up to 95.5% and the compact size of time and regularly wear out. Operating the power supplies. temperature of the componant plays an Limited space for building automation is important role in this process; every 10 often the rule rather than the exception. kelvin of temperature increase halves the Power supplies are often located in false service life of an electrolytic capacitor floors or in the ceiling space – usually and thus the power supply. For this rea- with very restricted height. Intensive de- son PULS only use electrolytic capacitor velopment work has seen power supplies designs with a high initial lifetime and reduce in size significantly over recent take care to achieve the lowest possible years. For example 960W units with componant temperature (see graph 1). XT40.481 a 3-phase input have shrunk from an overall width of 275mm in 1993 to an But what happens when 1000 power This is often achieved by the use of NTCs overall width of only 96mm for present supplies are simultaneously switched on? (resistor with a negative temperature day units. With commonly available power supplies coefficient). However, these components very high inrush currents would occur. pose a design problem as they heat up The efficiency of the unit is the key to a The Mecca project therefore placed parti- to +170°C and act as a „hot spot“ radi- compact unit size and low heat. For this cular demands on the inrush current. The ating heat to adjacent components the reason standard circuit concepts were solution was an electronic inrush current entire time the system is in operation. repeatedly rejected and replaced with in- limiter so that the inrush current would For this reason, in the Dimension series novative, low loss concepts and the later not overload the lines, the power supply they are replaced with an electronic constructive arrangement was conside- and the fuses (see graph 2). circuit that generates very little heat. red as a criterion during the selection of the circuit concepts.

Input Current

96% 95 94 93 92 Input Voltage 91 90 Output Voltage 89 Output Current 88 2.5 5 7.5 10 12.5 15 17.5 20A

Graph 1: Highest efficiencies over entire load range Graph 2: Power supplies tur on behaviour with virtually no inrush current.

September 2013 rev. 1 Seite 2 / 3 www.pulspower.com Order number: AN50.01.en Harsh Operational Test: A power supply subjected to high voltage conditions.

A lightning strike to the top of the tower The tower has shone every night since poses a real threat to the Mecca Tower it was first illuminated at the grand control. This means that the power unveiling in late 2012, reliably showing supplies must have high immunity to millions of pilgrims „Mecca Time“, which ensure uninterrupted service even in the was also planned to be integrated in the event of a lightning strike. Tests car- calculation of global time. ried out using high voltage strikes on a power supply of 500kV / 4000A did not impair the function of the power supply. During the tests the circuits were expo- sed to both air discharge and multiple discharges to the power supply input. The robustness of the Dimension Series successfully protected the units from damage.

September 2013 rev. 1 Seite 3 / 3 www.pulspower.com Order number: AN50.01.en