Dms100 Quick Ref Guide

Total Page:16

File Type:pdf, Size:1020Kb

Dms100 Quick Ref Guide 2002 DMS-100 Family QUICK REFERENCE GUIDE TAM-1001-018 Standard 09.01 August 2002 YOUR GUIDE FOR: • Commonly used DMS CI: level commands • Commands for TABLE EDITOR, SFDEV, DMSSCHED SPMS, TABAUDIT, DMSMON, TRAVER, DISPCALL, SHOWAUD, LOGUTIL, DLOG, CLASS, DISKUT, DSKUT, PRSM, OMs, SOC, AFT, RASL, AUTOMATIC IMAGE DUMP, and SDM UNIX commands • Quick references for AIN, CCS7, LNP, ISDN, CLASS, ACD-MIS, CC MIS, SMDI, CompuCALL, Remotes, DMS- 250, STP Broadband, SDM, SPM, and Centrex IP • Tier II support tools for XPMIST, DEBUG, ISDN Q931, SPM PRI Q931, ACDDEBUG, TERMTRACE, C7TU, CALLTRAK, XPMTRAK, CMINFO, and REMLOGIN • Quick references for NTPs, IMs, and other documents • Product Engineering Codes (PECs) for circuit packs • Hardware shelf diagrams with circuit pack locations • Circuit pack descriptions section • SuperNode, XPM, and other diagrams • XPM/DTC port and link mapping diagrams • TOPS hardware including IP-XPM Gateway • TOPS MPX/IWS & Attendant Console keyboard layouts • DPP/BMC hardware and DPP commands • SuperNode, SPM, XA-Core, and other hardware • RTIF commands and procedures • DIP switch settings for 6X21, 6X50, and 6X85 DS1 cards Please read before using The 2002 DMS-100F Quick Reference Guide provides a quick ref- erence for commonly used commands, utilities, tools, hardware, and other job-supporting information. The intent of this document is not to replace Nortel Networks Technical Publications (NTPs) and other supporting documents. Its purpose is to consolidate as much usable job-related information as possible into a small pocket-size document for quick reference and on-the-job use. The 2002 DMS-100F Quick Reference Guide is intended for both Tier I and Tier II support users. Tier II support tools are segregated in an area near the back of the guide. Since the misuse of these tools could impair service, they should only be used by technicians that have been trained in their use. When there is a question about the technical accuracy of this docu- ment and its contents, the NTPs and other supporting documents have the final authority. Where possible, the information in this guide makes references to NTPs and other supporting documents. Those documents should be referenced for warnings, cautions, and other advisory information that may not exist in this guide due to the limitation of space. Hardware displayed in this document provides examples for refer- ence to circuit pack slot locations. For most of the examples, the vintages (releases) of various packs are not shown due to space lim- itations. Hardware examples may not be exactly as your office is provisioned due to optional pack assignments and the quantity of circuits equipped. For a list of packs and their vintage application, reference the PEC Code list and the circuit pack description area of this guide. Other supporting information can be found in the DMS- 100F Baseline Report and NTP 297-8991-805. Some of the hardware listed within this guide has been manufacture discontinued (MD’d). It has been left in the guide to support MD’d hardware that is inservice, and in most cases, still supported. For customers to order copies of this document within North Amer- ica, call toll free 1-877-662-5669 (Option 2, then Option 1). Nortel employees can order copies through Internal Distribution or through the Documentation Ordering Tracking System (DOTS) (see IDS Home Page at http://zrtps08m.us.nortel.com/). Any customer comments, suggestions, or corrections should be made through your Nortel Networks Regional Support Center. © 2002 Nortel Networks Printed in the United States of America. This document, or parts thereof, may not be reproduced without the written permission of Nortel Networks. Nortel Networks Confidential: The information contained in this document is the property of Nortel Networks. Except as specifically autho- rized in writing by Nortel Networks, the holder of this document shall keep the information contained herein confidential and shall protect same in whole or in part from disclosure and dissemination to third parties and use same for evaluation, operation, and maintenance purposes only. Information is subject to change without notice. Nortel Networks reserves the right to make changes in design or components as progress in engineer- ing and manufacturing may warrant. Nortel, Nortel Networks, DMS, DMS SuperNode, DMS-STP, and MAP are examples of trademarks of Nortel Networks. All other trademarks are the property of their respective holders. 2002 DMS-100 FAMILY QUICK REFERENCE GUIDE TAM-1001-018 August 2002 © 2002 Nortel Networks All rights reserved Printed in the United States of America This document, or parts thereof, may not be reproduced without written permission of Nortel Networks. WHAT’S NEW OR CHANGED FOR THIS ISSUE Page(s) • Added alphabetical index in back of the guide ............. 161—166 • Updated entire document for and through NA017 • Added more SPM quick reference information: — Verifying Crossover Messaging ......................................... 108 — SPM Primary Rate Interface (PRI)..................................... 109 — SPM PRI Trunk Tables Datafill Sequence and Notes........ 109 — SPM Trunk Provisioning Limits for pre-SP16....................110 — SPM EXECTAB lineup.......................................................110 — Exec lineups in table MNNODE for DMS250/500 ............110 — Exec lineups in table MNNODE for DMS100 offices........110 — DAL prefix on the same SPM.............................................111 — LED Alarm Indicators.........................................................112 — PREPDATACHNG command.............................................112 • Added SPM PRI Q931 Message Tracing Tool ....................... 150 • Added Centrex IP Client Manager Quick References: — PTE2000 Centrex IP Frame.................................................. 45 — Centrex IP Gateway MCG CPX8216T Chassis................... 45 — Centrex IP and Conventional Centrex Configuration .......... 46 — Centrex IP Client Manager Documentation References ...... 46 — Event Logs............................................................................ 46 • Added more SDM UNIX commands...................................... 127 • Added TOPS IP-XPM Gateway Peripheral ............................ 125 • Updated and added more PRISM information: — AUTOPROC command........................................................ 25 — Missing PRSU Files ............................................................ 23 — Obsolete/Obsolete Emergency PRSUs at VA status ........... 23 — Patching After Loading (PAL) ............................................ 25 — Post-Release Software Updates (PRSU) Statuses ............... 22 — PRSM Basic Commands, Syntax, and Examples ................ 24 — PRSU EXTENSIONS Using the Format 'AAANNTaa' ...... 22 — SPM loadfile destinations .................................................... 23 — SPM Patching After Return To Service (SPARTS) ............. 25 — Which PRSU files to keep/erase ......................................... 22 • Added Common Peripheral Controller Equip. (CPCE) Frame115 • Added FINDREF and CAPCI commands................................... 8 • Updated DEBUG BRISC and XA-Core verification data for NA015 and NA017................................................ 154 — 155 • Removed PATCHER information. • At Nortel’s request, removed UE9000 and AccessNode Products. Revision History Issue Date Cover Color 01.01 December 1993 White 02.01 May 1995 Blue 03.01 March 1996 Green 04.01 January 1997 Brown 05.01 January 1998 Black 06.01 January 1999 Light Gray 07.01 January 2000 Red 08.01 February 2001 Spanish Maroon 09.01 August 2002 Dark Green Table of Contents Abbreviations and Acronyms ................................................................ 1 Nortel Networks Technical Publications .............................................. 2 Installation Documentation .................................................................... 5 Software Optionality Control (SOC) .................................................... 7 DMS CI: Level Commands .................................................................... 8 OM Commands ..................................................................................... 10 Store File Editor Commands ............................................................... 11 Switch Performance Monitoring System (SPMS) Commands ......... 12 DMS Scheduler (DMSSCHED) Commands ....................................... 12 Table Audit (TABAUDIT) Commands ............................................... 12 LOGUTIL Info, Control, Routing, and Devices Commands ............ 13 LOGUTIL Log Browsing Commands ................................................ 13 DMSMON Commands ......................................................................... 14 DISPCALL Commands ........................................................................ 14 SHOWAUD Command ........................................................................ 14 IOC DSKUT NonMenu Commands ................................................... 15 SLM DISKUT NonMenu Commands ................................................. 15 Supernode Loading Procedure ............................................................ 15 RTIF Commands and Recovery .......................................................... 16 AMADUMP Commands ...................................................................... 17 CALLDUMP CI: Level Command ..................................................... 17 Mag Tape (9 Track) Commands ........................................................
Recommended publications
  • Telecom) Terms Glossary and Dictionary - A
    Tele-Communication (Telecom) Terms Glossary and Dictionary - A A & B Bit A & B Bit is used in digital environments to convey signaling information. A bit equal to one generally corresponds to loop current flowing in an analog environment; A bit value of zero corresponds to no loop Current, i.e. to no connection. Other signals are made by changing bit values: for example, a flash-hook is sent by briefly setting the A bit to zero. A Links A Links, also known as SS7 access links, connect an end office or signal point to a mated pair of signal transfer points. They may also connect signal transfer points and signal control points at the regional level with the A-links assigned in a quad arrangement. A&B Bit Signaling A&B Bit Signaling, also called 24th channel signaling, is a procedure used in T1 transmission facilities in which each of the 24Â T1 subchannels devotes 1 bit of every sixth frame to the carrying of supervisory signaling information. On T1 lines that use Extended SuperFrame(ESF) framing, the signaling bits are robbed from the 6th, 12th, 18th, and 24th frame, resulting in "ABCD" signaling bits. ABAM cable ABAM cable refers to a type of T1 cable. This cable was a 22 gauge, 100 ohm insulated, twisted pair. ABAM cable is no longer available, but you can easily find cable that meets the technical requirements. Abandoned Call Abandoned Call is a call in which the call originator disconnects or cancels the call after a connection has been made, but before the call is established.
    [Show full text]
  • Diccionario De Términos Y Acrónimos De Comunicaciones De Datos
    DICCIONARIO DE TÉRMINOS Y ACRÓNIMOS DE COMUNICACIONES L&M Data Communications S.A. www.LMdata.es Tf. 91.352.41.31 Diccionario de Términos y Acrónimos de Comunicaciones de Datos Diccionario de Términos y Acrónimos de Comunicaciones de Datos -1- L&M Data Communications S.A. www.LMdata.es Tf. 91.352.41.31 Sus comentarios y sugerencias para mejorar futuras ediciones, puede enviarlos a: [email protected] Toda la información actualizada sobre nuestros cursos y publicaciones en: www.LMdata.es Si quiere estar al día, visite en nuestro Web la Enciclopedia Virtual de las Comunicaciones: Tecnologías, Productos, Servicios, Historia, Noticias, Organismos, Empresas, etc. Diccionario de Términos y Acrónimos de Comunicaciones de Datos -2- L&M Data Communications S.A. www.LMdata.es Tf. 91.352.41.31 Dicionario de Términos y Acrónimos de Comunicaciones de Datos José Morales Barroso – Juan Luis Lázaro García L&M Data Communications v.2003 Diccionario de Términos y Acrónimos de Comunicaciones de Datos -3- L&M Data Communications S.A. www.LMdata.es Tf. 91.352.41.31 Diccionario Enciclopédico de Términos y Acrónimos de Comunicaciones de Datos Edición 06 de noviembre de 2003 © L&M Data Communications S. A. ISBN: 84-89416-24-9 Depósito Legal: M-13.544 Printed in Spain Todos los derechos reservados. Ninguna parte de este documento puede ser reproducida o transmitida por ningún medio electrónico o mecánico, grabación o cualquier otro método de almacenamiento y recuperación, sin permiso por escrito de L&M (Ley Orgánica 6/ 1987 de 11 Noviembre) Diccionario de Términos y Acrónimos de Comunicaciones de Datos -4- L&M Data Communications S.A.
    [Show full text]
  • NEI 13-10, Rev. 5, Cyber Security Control Assessments
    NEI 13-10 [Revision 5] Cyber Security Control Assessments February 2017 [BLANK PAGE] NEI 13-10 [Revision 5] Nuclear Energy Institute Cyber Security Control Assessments February 2017 Nuclear Energy Institute, 1201 F Street N. W., Suite 1100, Washington D.C. (202.739.8000) [BLANK PAGE] ACKNOWLEDGMENTS This document has been prepared by the nuclear power industry with input and guidance from the United States Nuclear Regulatory Commission. While many individuals contributed heavily to this document, NEI would like to acknowledge the significant leadership and contribution of the following individuals. Executive sponsor: James Meister Exelon Corporation Core project team: Patrick Asendorf Tennessee Valley Authority Matthew Coulter Duke Energy Corporation Ronald Cowley Talen Energy Corporation Nathan Faith Exelon Corporation Pam Frey Talen Energy Corporation Glen Frix Duke Energy Corporation Jan Geib South Carolina Electric & Gas Company William Gross Nuclear Energy Institute Christopher Kelley Exelon Corporation Ken Levandoski Exelon Corporation Tony Lowry Ameren Missouri Jerry Mills Duke Energy Corporation Jay Phelps South Texas Project Nuclear Operating Company Don Robinson Dominion Generation Geoff Schwartz Entergy James Shank PSEG Services Corporation Manu Sharma Exelon Corporation Laura Snyder Tennessee Valley Authority Larry Tremonti DTE Energy Brad Yeates Southern Nuclear Operating Company Michael Zavislak Tennessee Valley Authority NOTICE Neither NEI, nor any of its employees, members, supporting organizations, contractors, or consultants make any warranty, expressed or implied, or assumes any legal responsibility for the accuracy or completeness of, or assumes any liability for damages resulting from any use of, any information, apparatus, methods, or process disclosed in this report, or warrants that such may not infringe privately owned rights.
    [Show full text]
  • Hardware Description Manual Volume 2 of 5
    Critical Release Notice Publication number: 297-8991-805 Publication release: Standard 11.03 The content of this customer NTP supports the SN06 (DMS) software release. Bookmarks used in this NTP highlight the changes between the LEC0015 baseline and the current release. The bookmarks provided are color-coded to identify release-specific content changes. NTP volumes that do not contain bookmarks indicate that the LEC0015 baseline remains unchanged and is valid for the current release. Bookmark Color Legend Black: Applies to new or modified content for LEC0015 that is valid through the current release. Red: Applies to new or modified content for SN04 (DMS) that is valid through the current release. Blue: Applies to new or modified content for SN05 (DMS) that is valid through the current release. Green: Applies to new or modified content for SN06 (DMS) that is valid through the current release. Attention! Adobe® Acrobat® Reader™ 5.0 or higher is required to view bookmarks in color. 1 Publication History June 2005 Standard release 11.03 for software release SN06 (DMS). Updates made for this release are shown below: Volume 5 Added NTDX16AA (Q00946403) March 2004 Standard release 11.02 for software release SN06 (DMS). Updates made for this release are shown below: Volumes 1 – 3 No changes Volume 4 Card NT9X30AB is Manufacture Discontinued and is replaced by new card NT9X30AC. Volume 5 No changes September 2003 Standard release 11.01 for software release SN06 (DMS). Updates made for this release are shown below: Volumes 1 – 4 No changes Volume 5 Updates were made to NT9X76AA according to CR Q00177945.
    [Show full text]
  • QRG Book.Book
    2002 DMS-100 Family QUICK REFERENCE GUIDE TAM-1001-018 Standard 09.01 August 2002 YOUR GUIDE FOR: • Commonly used DMS CI: level commands • Commands for TABLE EDITOR, SFDEV, DMSSCHED SPMS, TABAUDIT, DMSMON, TRAVER, DISPCALL, SHOWAUD, LOGUTIL, DLOG, CLASS, DISKUT, DSKUT, PRSM, OMs, SOC, AFT, RASL, AUTOMATIC IMAGE DUMP, and SDM UNIX commands • Quick references for AIN, CCS7, LNP, ISDN, CLASS, ACD-MIS, CC MIS, SMDI, CompuCALL, Remotes, DMS- 250, STP Broadband, SDM, SPM, and Centrex IP • Tier II support tools for XPMIST, DEBUG, ISDN Q931, SPM PRI Q931, ACDDEBUG, TERMTRACE, C7TU, CALLTRAK, XPMTRAK, CMINFO, and REMLOGIN • Quick references for NTPs, IMs, and other documents • Product Engineering Codes (PECs) for circuit packs • Hardware shelf diagrams with circuit pack locations • Circuit pack descriptions section • SuperNode, XPM, and other diagrams • XPM/DTC port and link mapping diagrams • TOPS hardware including IP-XPM Gateway • TOPS MPX/IWS & Attendant Console keyboard layouts • DPP/BMC hardware and DPP commands • SuperNode, SPM, XA-Core, and other hardware • RTIF commands and procedures • DIP switch settings for 6X21, 6X50, and 6X85 DS1 cards Please read before using The 2002 DMS-100F Quick Reference Guide provides a quick ref- erence for commonly used commands, utilities, tools, hardware, and other job-supporting information. The intent of this document is not to replace Nortel Networks Technical Publications (NTPs) and other supporting documents. Its purpose is to consolidate as much usable job-related information as possible into a small pocket-size document for quick reference and on-the-job use. The 2002 DMS-100F Quick Reference Guide is intended for both Tier I and Tier II support users.
    [Show full text]
  • Engulfs Nortel
    CASE STUDY Gale of “Creative Destruction ” Engulfs Nortel Canadian Business History This case study was prepared by Sanjeev Kumar Sharma under the direction of Professor Joe Martin as the basis for class discussion rather than to illustrate either effective or ineffective handling of a managerial situation. Copyright 2011 by the Governing Council of the University of Toronto. To order copies or request permission to reproduce materials, write to the Rotman School of Management, Business Information Centre, Toronto, M5S 3E6, or go to www.rotman.utoronto.ca/bic. No part of this publication may be reproduced, stored in any retrieval system, used in a spreadsheet, or transmitted in any form or by any means, whether by photocopying, recording or by electronic or mechanical means, or otherwise, without the written permission of the Rotman School of Management. Gale of “Creative Destruction” Engulfs Nortel Introduction In 2000, Nortel was the largest Canadian company, both in terms of revenue and market capitalization. (See Exhibit 1.) According to Canadian technology writer Larry MacDonald, one of Nortel’s strengths up to that point was its ability to thrive in the face of adversity. “In fact, it is out of disruption and discontinuities in markets, products and technologies that Nortel has emerged triumphant many times over. They have been what Nortel looks for in order to survive and gain position. The legacy is an entrenched culture of change, speed and innovation.”1 Exhibit 1 Nortel’s Market Cap and Revenue reached record highs in 2000 (in US$) Nine years later Nortel initiated creditor protection proceedings under the Companies’ Creditors Arrangement Act in Canada and Chapter 11 in the United States.
    [Show full text]
  • Nortel Technology Lens: Analysis and Observations
    Nortel Technology Lens: Analysis and Observations Team Members: Peter MacKinnon, Research Associate Peter Chapman, Telecommunications Engineer Hussein Mouftah, Distinguished University Professor School of Electrical Engineering and Computer Science Faculty of Engineering University of Ottawa March 25, 2015 I Table of Contents Executive Summary i - x 1. Introduction 1.1 Preamble 1 1.2 Problem Statement 1 1.3 Summary to Approach & Methodologies 1 1.4 Data & Information Gathering 2 1.5 Principal Findings 3 2. Nortel Technology 2.1 Overview 4 2.2 Technology Environment over the Study Period 5 2.3 Corporate Perspective on Technology 7 2.4 Key Technical & Corporate Milestones 8 2.5 Technology-based Offerings 10 2.6 Nortel’s Right Angle Turn 13 2.7 Skunkworks 15 2.8 Professional Services 16 2.9 The Changing Status of Nortel Technology & Product Offerings 17 2.10 Access Products & Technology 18 2.11 Long-haul Optical 20 2.12 Summary 20 3. Nortel Acquisitions and Strategic Alliances 3.1 Preamble 22 3.2 Acquisitions: An Overview 22 3.3 Selected Acquisitions 25 3.4 Acquisition Summary 31 3.5 Strategic Alliances: A Sample 33 3.6 Sell-off of Assets 34 3.7 Summary 35 4. Technology Management 4.1 Preamble 36 4.2 Time to Market: Some Technical Delays & Missed Opportunities 36 4.3 R&D Expenditures 38 4.4 Research & Development Priorities 39 4.5 Nortel as ‘Definer’ versus ‘Contractor’ 40 4.6 Systems Engineering 42 4.7 Corporate Culture with Respect to R&D and Commercialization 42 4.8 Management Awareness of Nortel Technologies & Technical Strengths 43 4.9 Product Commercialization 43 4.10 Outsourcing & Headcount 44 4.11 Setting the Stage for Unanticipated Troubles 44 4.12 Summary 47 II Table of Contents (cont.) 5.
    [Show full text]
  • Remote Data Polling System Description and User Interface
    297-1001-524 DMS-100 Family Remote Data Polling System Description and User Interface BCS33 and up Standard 09.01 October 1991 i DMS-100 Family Remote Data Polling System Description and User Interface Publication number: 297-1001-524 Product release: BCS33 and up Document release: Standard 09.01 Date: October 1991 Copyright Northern Telecom 1989, 1990, 1991 All rights reserved. Information is subject to change without notice. Northern Telecom reserves the right to make changes in design or components as progress in engineering and manufacturing may warrant. NT, DMS, SuperNode, DMS-STP, DNC, and MAP are trademarks of Northern Telecom. DATAPAC is a trademark of Telecom Canada. Remote Data Polling System Description and User Interface BCS33 and up ii Publication history October 1991 BCS33 Standard 09.01 • Updated format to new Northern Telecom documentation standards March 1990 BCS30 Standard 08.01 • Added Table XFERSSYS and updated the DEFINE command • Added System Load Module information to Configuration Revision bars in the table of contents identify the sections where informa- tion has been changed. Revision bars in the outside margin of a page indi- cate text that has been added or revised. 297-1001-524 Standard 09.01 October 1991 iii Contents About this document v Applicability of this document v How to identify the software in your office v How the Remote Data Pooling System (XFER) documentation package is orga- nized vi Where to find information vi NT and Bell-Northern Research (BNR) trademarks and the products they represent vii
    [Show full text]
  • Switching System Codes
    COMMON LANGUAGE® Switching System Codes Telcordia Technologies Practice BR-751-100-460 Issue 4 November 1999 Proprietary — Licensed Material Possession or use of this material or any of the COMMON LANGUAGE® Product Codes, Rules, and Information disclosed herein requires a written license agreement and is governed by its terms and conditions. For more information, visit www.commonlanguage.com/notices. An SAIC Company BR-751-100-460 Switching System Codes Issue 4 Copyright Page November 1999 COMMON LANGUAGE® Switching System Codes Prepared for Telcordia Technologies by: Edward Betz This document replaces: Issue 3, April 1995 Technical contact: Edward Betz To obtain copies of this document, contact your company’s document coordinator or your Telcordia account manager, or call +1 800.521.2673 (from the USA and Canada) or +1 732.699.5800 (all others), or visit our Web site at www.telcordia.com. Telcordia employees should call +1 732.699.5802. Copyright © 1997-1999 Telcordia Technologies, Inc. All rights reserved. Project Funding Year: 1999 Proprietary — Licensed Material See confidentiality restrictions on title page. 2 BR-751-100-460 Issue 4 Switching System Codes November 1999 Trademark Acknowledgements 5ESS is a registered trademark of Lucent Technologies. AGF is a trademark of Ericsson North America, Inc. AKE is a trademark of Ericsson North America, Inc. AnyMedia is a registered trademark of Lucent Technologies. ARF is a trademark of Ericsson North America, Inc. ARK is a trademark of Ericsson North America, Inc. ARM10 is a trademark of Ericsson North America, Inc. ARM20 is a trademark of Ericsson North America, Inc. ARM202 is a trademark of Ericsson North America Inc.
    [Show full text]
  • Cyber Security Control Assessments
    NEI 13-10 [Revision 2] Cyber Security Control Assessments December 2014 [BLANK PAGE] NEI 13-10 [Revision 2] Nuclear Energy Institute Cyber Security Control Assessments December 2014 Nuclear Energy Institute, 1201 F Street N. W., Suite 1100, Washington D.C. (202.739.8000) [BLANK PAGE] ACKNOWLEDGMENTS This document has been prepared by the nuclear power industry with input and guidance from the United States Nuclear Regulatory Commission. While many individuals contributed heavily to this document, NEI would like to acknowledge the significant leadership and contribution of the following individuals. Executive sponsor: James Meister Exelon Corporation Core project team: Patrick Asendorf Tennessee Valley Authority William Gross Nuclear Energy Institute Christopher Kelley Exelon Corporation Jay Phelps South Texas Project Nuclear Operating Company The core project team was supported by: Nathan Faith Exelon Corporation Jan Geib South Carolina Electric & Gas Company James Shank PSEG Services Corporation Laura Snyder Tennessee Valley Authority Industry review team: Glen Frix Duke Energy Corporation Matthew Coulter Duke Energy Corporation Geoff Schwartz Entergy NOTICE Neither NEI, nor any of its employees, members, supporting organizations, contractors, or consultants make any warranty, expressed or implied, or assumes any legal responsibility for the accuracy or completeness of, or assumes any liability for damages resulting from any use of, any information, apparatus, methods, or process disclosed in this report, or warrants that such may not infringe privately owned rights. [BLANK PAGE] NEI 13-10 (Revision 2) December 2014 EXECUTIVE SUMMARY When the methodology to address cyber security controls was developed in the template for the cyber security plan, the industry believed there would be small handfuls of digital assets (CDAs) that would require a cyber security assessment.
    [Show full text]
  • Telecommunications Abbreviations and Acronyms Speakeasy Speed Test Index 0-9|A|B|C|D|E|F|G|H|I|J|K|L|M|N|O|P|Q|R|S|T|U|V|W|X|Y|Z
    Telecommunications Abbreviations and Acronyms Speakeasy Speed Test Index 0-9|A|B|C|D|E|F|G|H|I|J|K|L|M|N|O|P|Q|R|S|T|U|V|W|X|Y|Z Consultation ERKAN is pleased to provide this living document for unlocking the evergrowing vocabulary of Abbreviations and Acronyms of the Telecommunications w orld, including those of the early days before the word "Digital" was coined. We striv e to include all relevant terms and update the database frequently. Our coverage of more than 40,000 enteries is not "complete", contributions are gratefully acc epted. back to top - 0-9 - A|B|C|D|E|F|G|H|I|J|K|L|M|N|O|P|Q|R|S|T|U|V|W|X|Y|Z 0TLP Zero Transmission Level Reference Point 1/e First Edition 10ARSS No. 10A Remote Switching System 10B12B 10-Bits/12-Bits 10B2 10Base2 10BT 10BaseT 10FR Ten Party Flat Rate 10FSL 10.0 File System Layout 10X 10-Speed 12X 12-Speed 16CIF 16 times CIF 1AESS No. 1A Electronic Switching System 1ANCP No. 1A Network Control Point 1ASES No. 1A Service Evaluation System 1AVSS No. 1A Voice Storage System 1BTSPS No. 1B Traffic Service Position System 1EAX No. 1 Electronic Automatic Exchange 1ESS No. 1 Electronic Switching System 1FR One-Party Flat Rate 1MM 1 Meg Modem 1MMS 1 Meg Modem Service 1MR One-Party Message Rate 1NCP No. 1 Network Control Point 1NF First Normal Form 1P 1-Party Line (Individual Line) 1PSS No. 1 Packet Switching System 1STP No.
    [Show full text]
  • 297-1001-825
    297-1001-825 DMS-100 Family Glossary of Terms and Abbreviations Reference Manual NA008 Standard 04.03 August 1999 DMS-100 Family Glossary of Terms and Abbreviations Reference Manual Publication number: 297-1001-825 Product release: NA008 Document release: Standard 04.03 Date: August 1999 1992–1999 Northern Telecom All rights reserved Printed in the United States of America NORTHERN TELECOM CONFIDENTIAL: The information contained in this document is the property of Northern Telecom. Except as specifically authorized in writing by Northern Telecom, the holder of this document shall keep the information contained herein confidential and shall protect same in whole or in part from disclosure and dissemination to third parties and use same for evaluation, operation, and maintenance purposes only. Information is subject to change without notice. Northern Telecom reserves the right to make changes in design or components as progress in engineering and manufacturing may warrant. DMS, DMS SuperNode, MAP, Nortel, and NT are trademarks of Northern Telecom. DMS-100 Family Glossary Reference Manual NA008 iii Publication history August 1999 BASE08 Standard 04.03 Updated the definition for the Cutoff On Disconnect (COD) feature. March 1998 BASE08 Standard 04.02 Text converted to comply with Nortel Standard English. May 1997 BASE08 Standard 04.01 Added terms. December 1993 BCS36 Standard 03.01 • made technical and editorial changes to existing terms • added terms March 1993 BCS35 Standard 02.01 • made technical and editorial changes to existing terms
    [Show full text]