Hardware Description Manual Volume 2 of 5
Total Page:16
File Type:pdf, Size:1020Kb
Critical Release Notice Publication number: 297-8991-805 Publication release: Standard 11.03 The content of this customer NTP supports the SN06 (DMS) software release. Bookmarks used in this NTP highlight the changes between the LEC0015 baseline and the current release. The bookmarks provided are color-coded to identify release-specific content changes. NTP volumes that do not contain bookmarks indicate that the LEC0015 baseline remains unchanged and is valid for the current release. Bookmark Color Legend Black: Applies to new or modified content for LEC0015 that is valid through the current release. Red: Applies to new or modified content for SN04 (DMS) that is valid through the current release. Blue: Applies to new or modified content for SN05 (DMS) that is valid through the current release. Green: Applies to new or modified content for SN06 (DMS) that is valid through the current release. Attention! Adobe® Acrobat® Reader™ 5.0 or higher is required to view bookmarks in color. 1 Publication History June 2005 Standard release 11.03 for software release SN06 (DMS). Updates made for this release are shown below: Volume 5 Added NTDX16AA (Q00946403) March 2004 Standard release 11.02 for software release SN06 (DMS). Updates made for this release are shown below: Volumes 1 – 3 No changes Volume 4 Card NT9X30AB is Manufacture Discontinued and is replaced by new card NT9X30AC. Volume 5 No changes September 2003 Standard release 11.01 for software release SN06 (DMS). Updates made for this release are shown below: Volumes 1 – 4 No changes Volume 5 Updates were made to NT9X76AA according to CR Q00177945. 2 297-8991-805 DMS-100 Family Hardware Description Manual Volume 2 of 5 2001Q1 Standard 09.01 March 2001 DMS-100 Family Hardware Description Manual Volume 2 of 5 Publication number: 297-8991-805 Product release: 2001Q1 Document release: Standard 09.01 Date: March 2001 Copyright © 1994-2001 Nortel Networks, All Rights Reserved Printed in the United States of America NORTEL NETWORKS CONFIDENTIAL: The information contained herein is the property of Nortel Networks and is strictly confidential. Except as expressly authorized in writing by Nortel Networks, the holder shall keep all information contained herein confidential, shall disclose the information only to its employees with a need to know, and shall protect the information, in whole or in part, from disclosure and dissemination to third parties with the same degree of care it uses to protect its own confidential information, but with no less than reasonable care. Except as expressly authorized in writing by Nortel Networks, the holder is granted no rights to use the information contained herein. Information is subject to change without notice. Nortel Networks reserves the right to make changes in design or components as progress in engineering and manufacturing may warrant. Changes or modifications to the DMS-100 without the express soncent of Nortel Networks may void its warranty and void the user’s authority to operate the equipment. Nortel Networks, the Nortel Networks logo, the Globemark, How the World Shares Ideas, Unified Networks, DMS, DMS-100, Helmsman, MAP, Meridian, Nortel, Northern Telecom, NT, and SuperNode are trademarks of Nortel Networks.. iii Contents Volume 2 of 5 1 NT2Xnnaa (continued) 1-1 NT2X58AU through NT2X90AD (continued from Vol. 1) 1-1 NT2X58AU 1-2 NT2X58CB 1-7 NT2X58CF 1-12 NT2X59AA 1-21 NT2X59AB 1-27 NT2X59AC 1-33 NT2X59AD 1-38 NT2X59BA 1-43 NT2X59CA 1-48 NT2X59CB 1-53 NT2X59DA 1-58 NT2X59EA 1-63 NT2X65AB 1-68 NT2X65AD 1-76 NT2X66AA 1-84 NT2X70AA 1-90 NT2X70AE 1-93 NT2X70AF 1-96 NT2X70KA 1-99 NT2X71AA 1-102 NT2X72AA 1-110 NT2X72AB 1-118 NT2X72AC 1-126 NT2X72BA 1-134 NT2X72BB 1-142 NT2X75AA 1-150 NT2X77AA 1-155 NT2X77AB 1-158 NT2X77AC 1-161 NT2X77AD 1-164 NT2X77BA 1-167 NT2X78AA 1-169 NT2X80AA 1-177 NT2X81AA 1-180 NT2X81AB 1-188 DMS-100 Family Hardware Description Manual Volume 2 of 5 2001Q1 iv Contents NT2X81AC 1-195 NT2X81BA 1-202 NT2X82AA 1-208 NT2X83AA 1-214 NT2X84BA 1-222 NT2X85AA 1-230 NT2X86AA 1-238 NT2X88AA 1-247 NT2X90 1-255 NT2X90AB 1-274 NT2X90AC 1-288 NT2X90AD 1-302 NT2X96AA 1-321 NT2X96BA 1-324 2 NT3Xnnaa 2-1 NT3X02AA through NT3X95BB 2-1 NT3X02AA 2-2 NT3X03 2-7 NT3X04AA 2-12 NT3X05AA 2-15 NT3X06AA 2-19 NT3X07AA 2-28 NT3X08AA 2-36 NT3X08AB 2-41 NT3X09AA 2-47 NT3X09BA 2-51 NT3X13AA 2-55 NT3X13BA 2-62 NT3X14AA 2-69 NT3X14BA 2-74 NT3X14BB 2-79 NT3X14BC 2-84 NT3X15AA 2-89 NT3X15AB 2-93 NT3X15BA 2-97 NT3X15BB 2-101 NT3X15CA 2-105 NT3X15DA 2-109 NT3X16AA 2-113 NT3X16AB 2-118 NT3X16BA 2-123 NT3X16BB 2-127 NT3X22AB 2-131 NT3X25BA 2-133 NT3X25BB 2-134 NT3X40AA 2-135 NT3X45EW 2-142 NT3X48AA 2-146 NT3X65AA 2-151 297-8991-805 Standard 09.01 March 2001 Contents v NT3X67AA 2-156 NT3X67BB 2-159 NT3X68AA 2-162 NT3X68AB 2-165 NT3X68AC 2-168 NT3X68BB 2-170 NT3X68BC 2-173 NT3X82AA 2-175 NT3X82AB 2-184 NT3X82AC 2-191 NT3X82AD 2-200 NT3X82AE 2-209 NT3X82BA 2-218 NT3X83AA 2-238 NT3X83AB 2-248 NT3X83BA 2-258 NT3X84AA 2-267 NT3X85AA 2-275 NT3X89CA 2-283 NT3X89EA 2-285 NT3X91AA 2-288 NT3X93AA 2-294 NT3X95AA 2-300 NT3X95AB 2-303 NT3X95BA 2-306 NT3X95BB 2-309 3 NT4Xnnaa 3-1 NT4X00AC through NT4X98AA 3-1 NT4X00AC 3-2 NT4X00AF 3-5 NT4X00AG 3-8 NT4X09BB 3-11 NT4X25DA 3-18 NT4X45AA 3-21 NT4X70 3-26 NT4X71 3-33 NT4X77 3-49 NT4X80BA 3-61 NT4X80CA 3-65 NT4X98AA 3-69 4 NT5Xnnaa 4-1 NT5X00AC through NT5X98AA 4-1 NT5X00AC 4-2 NT5X00D 4-6 NT5X03AA 4-10 NT5X04AA 4-19 NT5X04AB 4-25 NT5X06AA 4-30 DMS-100 Family Hardware Description Manual Volume 2 of 5 2001Q1 vi Contents NT5X08AC 4-38 NT5X12AB 4-40 NT5X13 4-44 NT5X18AA 4-55 NT5X25 4-61 NT5X29AA 4-69 NT5X29AB 4-78 NT5X29AC 4-86 NT5X29BA 4-93 NT5X30AA 4-100 NT5X30BA 4-107 NT5X64 4-115 NT5X92 4-126 NT5X95AA 4-131 NT5X97 4-134 NT5X98AA 4-144 5 NT6Mnnaa 5-1 NT6M56AB through NT6M71AB 5-1 NT6M56AB 5-2 NT6M66AC 5-3 NT6M68AA 5-5 NT6M71AB 5-6 6 NT6Xnnaa 6-1 NT6M56AB through NT6X02DD (continued in Vol. 3) 6-1 NT6X01AA 6-2 NT6X01AB 6-6 NT6X01AC 6-10 NT6X01BA 6-14 NT6X02AA 6-18 NT6X02AC 6-24 NT6X02AD 6-31 NT6X02AE 6-37 NT6X02AF 6-43 NT6X02AG 6-49 NT6X02AH 6-55 NT6X02AK 6-61 NT6X02AL 6-67 NT6X02AM 6-73 NT6X02AQ 6-78 NT6X02AR 6-83 NT6X02AS 6-89 NT6X02AT 6-95 NT6X02AU 6-102 NT6X02AW 6-109 NT6X02AY 6-115 NT6X02AZ 6-120 NT6X02BA 6-126 NT6X02BK 6-132 297-8991-805 Standard 09.01 March 2001 Contents vii NT6X02CA 6-138 NT6X02CC 6-144 NT6X02CD 6-150 NT6X02CP 6-155 NT6X02CQ 6-161 NT6X02CS 6-167 NT6X02DA 6-173 NT6X02DB 6-179 NT6X02DC 6-186 NT6X02DD 6-193 DMS-100 Family Hardware Description Manual Volume 2 of 5 2001Q1 1-1 1 NT2Xnnaa (continued) NT2X58AU through NT2X90AD (continued from Vol. 1) DMS-100 Family Hardware Description Manual Volume 2 of 5 2001Q1 1-2 NT2Xnnaa (continued) NT2X58AU Product Description The NT2 NT2X58AU international maintenance trunk module (MTM) for the digital recorded announcement machine (DRAM) shelf has the circuit cards that store recorded phrases. The NT2X58AU for DRAM shelf and the digital multiplex system (DMS) control module (CM) route the circuit cards to speech channels. The NT2X58AU and DMS perform this action when necessary. This shelf is part of the NT0X46AB frame. This shelf houses digital recorded announcement circuit cards. The NT0X46AB frame can have a maximum of four NT2X58AU The DRAM control section makes and maintains connections. The DRAM control section controls the module operation. The DRAM control section has the following cards: • NT2X45BA trunk module (TM) interface card • NT0X70BA international TM circuit card • NT2X53AA TM control card • NT2X59BA A-law coder-decoder (CODEC) and tones circuit cards The DRAM unit has a speech processor, a microprocessor controller, and speech memory on circuit cards. The microprocessor controller and speech processor are on the NT1X75DA controller card for enhanced digital recorded announcement (DRA). You can use a group of any or all three different cards to provide the speech memory. The three different cards are the NT1X76AA PROM card, the NT1X77AA RAM card and the NT1X79AA EEPROM card. The unit must contain at least one PROM or RAM card. You can use any group from eight PROM, EEPROM, or RAM cards. An NT2X58AU shelf at a specified customer site can have additional provisional cards. You can choose these additional cards from the following: • test signal generators • pulse code modulated (PCM) level meters • line test cards • minibar drivers • looparound test line cards Space for these additional cards is available when the shelf has less than eight speech memory cards. 297-8991-805 Standard 09.01 March 2001 NT2Xnnaa (continued) 1-3 NT2X58AU (continued) Each NT2X58AU shelf has one of the following common circuit packs: • NT2X58AY-replaces NT2X58AS • NT2X58CL-replaces NT2X58CC • NT2X58DB-replaces NT2X58DA The NT2X58AU shelf must not have office alarm circuits. Parts The NT2X58AU has the following components: • NT0X70BA-international trunk module card • NT1X75DA-enhanced DRA controller card • NT1X76AA-PROM cards • NT1X77AA-RAM cards • NT1X79AA-EEPROM cards • NT2X09AA-multioutput power converter card • NT2X45BA-trunk module interface card • NT2X53AA-trunk module control card • NT2X59BA-A-law CODEC and tones card Design The components of the NT2X58AU are described in the following table. The design of the NT2X58AU appears in the figure that follows the table.