P13 AC Technical Data Sheet
Total Page:16
File Type:pdf, Size:1020Kb
P13 SD Data Sheet P13 HV AC Series On/Off/Jog/Proportional ISO5211 F25 R72 Actuator Specifi cations P13 Torque “lb/Nm 40000”lbs/4500Nm Also available in 3 phase supply. Separate spec Supply Voltage 120vac 230vac sheets are available for these configurations. Max Inrush Current 8.0A 4.8A See www.promationei.com for more Running Current 4.2A 2.4A information or call ProMation Engineering. Motor Split Phase Capacitor Runtime (90°@60Hz/vdc) 80 sec Runtime (90O@50Hz) 95 sec Duty Cycle 25%, Proportional: Managed (75% maximum) Motor Starts 1200 per hour Weight 240lbs/109kg Mechanical Connections ISO5211 F25 Rnd 72mm Electrical Entry (2) 3/4” NPT Electrical Terminations 12-16ga Environmental Rating NEMA 4/4X Manual Override 15.6” Handwheel Control On/Off-Jog, Proportional Actuator Case material Aluminum Alloy, Powder coated 230°F/110°C Thermal F* Class Motor Protection *Totally Enclosed Non-Ventilated Motors Ambient Temperature -22°F to +125°F Operating Range -30°C to +52°C An electric actuators designed for load requirements up to 40000”lbs. Each actuator comes standard with two auxiliary switches (Form C), an internal low power heater, a NEMA 4X environmental rating, and in 120vac and 230vac supply voltages. The P13 mechanical connections are ISO5211 compliant. The P13 Series can be ordered as an on/off (two position) model that can be used in bump/jog applications as well. Models can also be ordered with internal proportional control cards that accept a wide range of control signals and generate multiple feedback signals for field use. Product Family Voltage Options Control Options Special Designations SD15_P213_HV Ver N_100915 SD15_P213_HV Ver P 13 - 120 P N 4 On/Off RO Relay Open (2 pos) 120 120VAC+10% Non-Spring 40000”lbs / 4500Nm Proportional Relay Close (2 pos) 13 P N Return 4 RC 230 230VAC+10% NEMA 4X TS Torque Switch Note: Not all combinations are possible. Please consult factory. CSA Certified Duty Cycle Graph DutyDuty Cyclecycle Graphgraph 100% 100% • Duty cycle is defi ned as the ratio of total time vs. run time, and is a function of environmental conditions including ambient 75% 75% Proportional ® Proportional temperature, supply voltage and control signal stability 50% 50% • Duty Cycle rating on all proportional control actuators is managed (75% maximum). On/Off/Jog C US On/Off/Jog 25% 204450238703 25% 50°F 75°F 100°F 125°F 150°F 50°F 75°F 100°F 125°F 150°F 10°C 24°C 38°C 52°C 65°C 10°C 24°C 38°C 52°C 65°C Ambient Temperature Ambient Temperature Page 1 of 4 P13 HV Series CSA Certified Duty Cycle Graph Duty Cycle Graph 100% 100% 75% 75% 50% 50% On/Off/Jog On/Off/Jog 25% 25% 50°F 75°F 100°F 125°F 150°F 50°F 75°F 100°F 125°F 150°F 10°C 24°C 38°C 52°C 65°C 10°C 24°C 38°C 52°C 65°C Ambient Temperature Ambient Temperature CSA Certified Duty Cycle Graph Duty Cycle Graph 100% 75% On/Off/Jog / Proportional On/Off/Jog / Proportional 50% 25% 50°F 75°F 100°F 125°F 150°F 50°F 75°F 100°F 125°F 10°C 24°C 38°C 52°C 65°C 10°C 24°C 38°C 52°C Ambient Temperature Ambient Temperature 2 1 P13 Series Dimensional Data Engineering Change Notice REV Change Date Description Name P Series Exploded View A 02.10.2014 New Document KHL B 04.15.2014 Added tolerance on drive coupling data KHL (Typical) P13 SeriesC 10.07. 201Views4 Pushed output diameter dimension to three decimal places, added keyway dimension KHL D 04.08.2015 Added Isometric view of Drive Coupling and "Depth" tag for clarity KHL (Typical)E F Easily distinguishable 445 mm yellow/red position 17.5 in indicator 263 mm 10.3 in 504 mm 19.8 in Aluminum Casting B B 4X Protection 262 mm (2) 3/4" NPT 10.3 in EMT Entry Modular Control Cards Heavy Duty Drive Motor 571 mm 22.5 in Easily accessible Add 254mm 398 mm NEMA 4 15.7 in switch & [10"] to allow Cover Seal for cover cam stacks removal Aluminum Casting 4X Protection 364 mm 254 mm 219 mm 285 mm 14.3 in 10.0 in 8.6 in 11.2 in BHC Worm Drive (8) M16x2.00 Drive Coupling Fabrication Data 25mm 20.00 mm 28.50 mm 1.0" .787 in KEY 1.122 in Keyway 20.00 mm 12.00 mm .787 in .472 in A A 22.5° +.00 72.00 mm 110.00 mm - .13 Epicyclic Gearing 4.331 in +0.000 72.00 mm 2.835 - in F25 ISO Flange Depth 0.005 2.835 in Mechanical Stop Clutchless Override Handwheel Drawn By Created: Part No. Screws (2) KHL Application2/10/2014 Notes: ProMation Engineering, Inc. Checked By Last Checked: Dwg. Name KHL 1.4 /8/201These5 Tactuatorshis Document is the p roareperty of PtoroM atbeion En gmountedineering, ONLY betweenP13 Fa2 5horizontal R72 DimData.id wand upright position. Material Finish Inc. Distribution of this document without the written consent of the owner is Strictly forbidden. Rev. 2. When installingFailure to comply w iconduit,ll incur a liability for Duseamages. proper techniques for Pentry13 Dim intoData the actuator. Use drip loops to prevent D Dimensional Tolerances (Unless Otherwise conduitNoted): Pro mcondensateation Engineering Inc. from entering the actuator. X.X ± .3 [X.XX ± .01] Dimensional Data for P13 Actuators 16138 Flight Path Drive Phone: 352-544-8436 X.XX ± .13 [X.XXX ± .005] Brooksville, Fl 34604 Fax: 352-544-8439 ALL TOLERANCE FEATU3.RES IN mmBoth NPT conduit ports MUST use NproperO SCALE equipment to protect theS NEMAheet Num 4Xber: 1integrity of the housing. 4. The 2anti-condensate heater is to be used in ALL applications.1 5. Do not install or store the actuator outdoors or in humid environments without power to the heater. 6. Use proper wire size to prevent actuator failure (see wire sizing chart). 7. Mechanical travel stops exist to prevent over-rotation for manual override only. They are not intended to stop motor driven rotation. 8. Do not parallel wire multiple actuators together without utilizing isolation relays! If this is your intention, please contact ProMation Engineering for a multiple actuator parallel wiring diagram. SD15_P213_HV Ver N_100915 SD15_P213_HV Ver Switch Logic Map and Switch/Cam Arrangement Switch sequencing data is provided in the table below to show CW CCW the change-of-state points during the rotation of the actuator -5° 0° 5° 85° 90° 95° from OPEN to CLOSED and back again. The red bar indicates when that terminal makes with it’s respective common. 12 Not Open SW1 and SW2 are set at the factory and should NOT be Open Common SW4 CW AUX 11 (Factory Set - Adj) changed. The INCLUDED auxiliary switches SW3 & SW4 are for terminals 7 thru 12 and those setpoints may be modifi ed if 10 Open } need be. When so optioned, SW5 & SW6 auxiliary switches are initially set to function the same as auxiliary switches 9 Not Closed SW3 & SW4. ID# Terminal SW3 CCW AUX 8 Closed Common (Factory Set - Adj) } Used by 7 Closed } Controller On/Off Switch/Cam arrangement shown Page 2 of 4 P13 HV Series Wiring Diagrams for P13 Series On/Off/Jog Control • Field Control Device may be relay contact, SAMPLE DIAGRAM Switch or Triac type. Refer to the proper IOM for your actuator for the • Pilot device 10A MAX. Auxiliary switches are correct wiring diagram or visit www.promationei.com. rated 10A @ 250vac MAX. • Terminals 7-12 are dry type Form C. • Terminals accept 12-16ga solid/stranded wire. 430-10100 Switch Card NOT OPEN* 12 OPEN COM* 11 AUXILIARY P13 SD WD SWITCH SW4 (STANDARD) OPEN* 10 * CONNECTIONS OPTIONAL NOT CLOSED* 9 CLOSED COM* 8 AUXILIARY SWITCH SW3 (STANDARD) CLOSED* 7 FIELD RUN OPEN 6 THERMAL CONTROL 1 SWITCH DEVICE SW1 1 Capacitor M OPEN PILOT* 5 2 120V RUN CLOSED AC DRIVE 4 MOTOR SW2 J1 120VAC CLOSED PILOT* 3 LINE IN 3 E2 HEATER E1 WD-850-54101 2 Direct Mount NEUTRAL 4 Heater 1 J3 ALL SWITCHES HOT J2 SHOWN WITH 410-50100 ACTUATOR IN TL25-1800 GND FULL OPEN POSITION E2 E1 Wire Sizing Chart GND Screw MAX distance between Actuator Items within dotted line located inside actuator housing and Supply (feet) Actuator/ P13 P13 Actuator ships in fully closed position! Voltage 120VAC 230VAC Amps Wire 8.0A 4.8A Wire sizing data is provided in the Wire Sizing Chart Gage to assist in the selection of the proper wire size for 16 A - 519 ProMation P Series actuators using various wire 14 262 838 sizes over distance. 12 401 1281 Please make sure to reference the correct voltage 10 682 2178 and do not exceed the indicated length of the wire SD15_P213_HV Ver N_100915 SD15_P213_HV Ver P9~13 120N4 8 1018 3251 run for each model. Proportional Control ProMation Premium Controller: The Premium controller offers a full array of features - such extensive data logging that provides full proportional control as various control and feedback signals, alphanumeric for all industrial applications. ModBus communications are readout, several fault indicators for operational diagnostics, also an option on this controller. Control Signal Inputs Feedback Signal Output Full Proportional Control (selectable using program menu): (Can be different than input): Featuring: 0-10vdc, 1-5vdc, 2-10vdc, 4-20mA 0-10vdc, 1-5vdc, Factory set with common isolated from 2-10vdc, 4-20mA • Autocalibration ground. Ground reference is possible.