! ! ! ! ! ! ! ! ! ! ! ! Royal Nelson Technical Specifications ! ! ! ! ! ! ! ! Technical Manager Theatre Manager !JR Richardson Janice Marthen 027 461 6458 (03) 548 3840 (ext 3) (03) 548 3840 (ext 1) [email protected] [email protected] www.theatreroyalnelson.co.nz

Any electrical equipment brought in must display a current safety test tag Dimensions !Setting line is the upstage edge of the proscenium Stage Surface painted ply-wood Stage height 890mm Proscenium arch 8100mm wide x 4900mm high Edge to setting line 1230mm Stage depth 8540 mm (Setting line to face of upstage wall) !Stage weight loading max 500kg per square metre Wing Dimensions Wing-space OP 6500mm to wall Wing-space PS 2000mm to Fly controls Stage floor to underside gallery walkway 5000mm Stage floor to gallery handrail 6800mm !Gallery handrail height 1000mm Dock / Stage Access Dimensions Loading dock door: 2750mm wide x 2800mm high !Upstage scene door: 3300mm wide x 2700mm high Dock is set 1250mm up, and 2300mm back from closest sealed vehicle access due to a 300mm high landing for the adjoining pedestrian entrance. !Vehicle access via Vanguard Street, driveway north of Cory’s Electrical Fly Tower Specifications in-dead 1300 mm (top of batten) Batten out-dead 10450 mm (top of batten) Maximum drift 9150 mm !Stage floor to grid 10670 mm (underside) Battens are 75 x 50 mm RHS Batten length 10600 mm Suspension wires 4x 6mm wire rope, 1600mm & 4800mm from center Cradle Slaves 2x units 2-5 line span Max distributed load per batten is 400 Kg !Max point load is 200 Kg Orchestra Pit A section of the auditorium floor can be removed in two configurations exposing an MD or the full pit !without disturbing the seating plan. Contact the house technician to discuss options. Pit Depth 1500mm below auditorium floor, 2400 below stage Orchestra Pit room 3500mm x 8000mm - Concave front wall Band Room 6800mm x 8000mm Pit opening Full 8000mm wide !Pit opening Partial 1100mm wide x 1500mm deep (to stage front) !

Any electrical equipment brought in must display a current safety test tag Masking 1x House curtain Red velvet, overlapped split 5x Pairs of black legs 6m with returns 4x Black borders : 3m drop 1x Black tabs 6m drop 2x Tab Tracks 1x Black ground-row 400mm High 1x Cyc Screen Black front or rear projection PVC !2x Cinema Screens 1x White, 1x Silver (extra labour required to install, please discuss options) Sound System 4x QSC K12 Speakers 2x EAW VR-62 front fill speakers run off a QSC USA450 amplifier 2x Peavey Q118 subs run of a Samson SX3200 amplifier. 1x DBX Driverack 260 1x Allen & Heath ZED16 - 8Mic Pre mixer 3x 12/4 XLR Snakes 10x XLR Returns to Amp rack 2x Stage fill JBL M825 speakers run off a Phonic amp 1x TASCAM CD-1U CD player 2x SM58 microphones and stands

Front fill speakers are mounted above the proscenium arch providing high frequency fill to the first few rows in the stalls. K12s are flown in two pairs; one from each FOH truss. FOH 1 pair is tilted to cover most of the stalls. FOH 2 pair is flown flat and covers the back of the stalls and the balcony. Subs are positioned on the auditorium floor, either side of the proscenium arch.

The system is tuned via a Driverack 260. K12s are run in stereo pairs, channels 1 through 4, Subs and Front Fill are mono, on channels 5 and 6 respectively. Drive-rack settings are locked with access at the discretion of the Theatre Royal Technical Manager and BB Sound.

This system provides excellent coverage throughout the auditorium to 100dBa and is suitable for theatre, music theatre, dance playback and concert applications.

Power Standard 10A and technical earth 10A (for Audio) outlets are located throughout the facility

On Stage 5x 40A Outlets 1x 40A Outlet (Technical Earth) 2x 63A Outlets 1x 300A Lighting Powerlock 1x 200A Sound Powerlock Operating Position 1x 40A Outlets 1x 40A Outlet (Technical Earth) Loading dock 1x 63A Outlet Gallery Level 3x 40A Outlets Fly Level 1x 40A Outlets Rehearsal Room 2x 40A Outlets Auditorium ceiling 2x 40A Outlets Band Room 1x 40A Outlets 1x 40A Outlet (Technical Earth)

Any electrical equipment brought in must display a current safety test tag !Rigging & Hanging Positions FOH 1: 9m alloy box truss, fixed, 60° to setting line 5.4m high, 3.1m from setting line (60°) FOH 2: 9m alloy box truss on 2x 500kg motors 5.4m high, 4.7m from setting line (45°) Arch Bar: 8m Ladder bar on 2x chain hoists ! 120mm Downstage of curtain - Front fill speakers installed Overhead: 4x Internally wired bars, 20 circuits each, counterweight flown 2x Auxiliary scaffold pipe bars, counterweight flown ! 3x Ladders on both PS & OP Pan Bars, counterweight flown !Floor: 8 Baseplates and a range of scaffold pipe and clips Access: Genie-lift and a variety of ladders for focussing etc. ! Lighting System

Lamp-stock: 24x Selecon Fresnel 1200 with B/Doors 6x Selecon PC 1200 with B/Doors 12x Pacific 14/35 13x Pacific 23/50 30x Par 64 Can (CP62 lamp) 4x 4 Way Selecon 1000W Cyc Units 2x Mini Fresnel 650W 12x A sized Holder 10x B sized gobo holder ! 11x Iris for Pacific !Extra lamps can sourced for hire locally, please advise if you require. Control Equipment 1x 120 Channel Theatrelight Cuemaster Control Desk 64x 2.4KW Dimmers DMX (Theatrelight PID II) 1x 12channel Theatrelight DMX Dimmer pack 260x Waylines to stage, gallery, fly floor and auditorium 1x IEC Based patch bay ! 1x 10 Channel DMX splitter + way-lines to stage, gallery and auditorium House Lights All auditorium lights are on an independent dimming system with controllers at the SM panel, Foyer !and the standard operating position. Standard Configuration Our standard lighting configuration provides the following (plan attached) - Full stage warm and cool front light - Full stage back-light - Full Stage Break-up Gobo - Red and Blue Front Colour - Four colour of side-light - 8x Spotlight specials - 4 Colour Cyc wash

Any electrical equipment brought in must display a current safety test tag Backstage Dressing Rooms 4x 2 per stage & 2per 2nd level. Avg. dimension 5.5m x 2.7m Each with wide, lit makeup mirrors. Bench and swivel seating.

Rehearsal Room 8m x 11.2m Carpeted room with attached kitchenette on the 3rd level

Toilets 5x 2per Stage level, 3per 2nd level Shower 2x 1per Stage and 2nd level

Kitchenette 2x 1per Stage & 3rd level w/ bench, sink, kettle microwave & fridge

Other Facilities

Dressing rooms 4x (2 stage level, 2 2nd level) Laundry 1x Washing Machine & Dryer 2x Iron & Board

Staging 7x Wooden risers 2400mm x 900mm x 290mm (h)

Piano Ehrbar 8 foot Grand Piano - Stage level only. Tuning available on request

Internet Direct fibre connection and wifi password available to occupants Data Cabling CAT6e throughout building terminating in patch bay in dimmer room

Comms 1x Clear-Com Base-station 3x Clear-Com Belt Units 4x Clear-Com Head-units Patch points throughout building

Spotting light Yes

Stage monitoring Camera fixed - 1 monitor per: dressing room, PS wing + 2x FOH

Wheelchair lift Links Wheelchair accessible Foyer to Stage and Pit levels Wheelchair facilities 1x Bathroom, 1x Shower on stage level

Blue Lights Throughout back of house

Security Magnetic locking to FOH- engaged during performance hours or as required. Keys issued to core crew. Pin-coded backstage door.

Air-conditioning Discrete programmable temperature control of the auditorium and stage. Fresh air supply to all back of house areas.

First Aid First Aid is located in the Dimmer Room

Fire Safety Heat Sensor based fire alarm, sprinkler system, smoke doors and Fire Extinguishers located throughout the building Smoke/Particle Alarm No !Fire Curtain No

Any electrical equipment brought in must display a current safety test tag Third Party Providers

We may not have everything you need in-house, but we do have amazing relationships with our preferred local hire companies. Please talk to us if you would like help sourcing any of the following:

Lighting Lamp fixtures : Generics, UV, LED or Intelligent Follow-spot Dimmers Control Desks

Rigging Truss or Scaffold Floor-based or Flown

Staging Rostra, Risers, Platforms and stairs

Dressing Drapery Gauze Cloth Tables / Chairs Decor & Design

Flying Specialised crew and equipment for the flying of scenery or persons

Sound Microphones and DI’s Mixing Desks: Analogue or Digital Outboard : Effects or Processing Monitoring / Extra Speakers Recording Solutions Back-line

Projection Presentation or Cinema Style Projection and Screen Solutions

Atmospheric Effects Smoke or Haze Machines

Pyrotechnic Effects Certified theatrical pyro-technicians

Firearms Licensed providers of blank stage firearms

Special Effects Laser Effects Dry Ice

Any electrical equipment brought in must display a current safety test tag Theatre Royal Nelson : Standard House Hanging Plot Setting line = Upstage edge of proscenium

Line set U/S of Set Line (mm) Item Height Notes 1 100 House Curtain 5.5m Red Velvet, overlapped split 2 280 Black Legs #1 6m 3 460 4 640 LX 1 20 Pre-Wired Circuits 5 820 6 1000 7 1180 8 1360 9 1540 Black Border # 1 3 m 10 1720 Black Legs # 2 6 m 11 1900 12 2080 13 2260 LX 2 20 Pre-Wired Circuits 14 2440 15 2620 16 2800 17 2980 18 3160 19 3340 20 3520 Black Border # 2 3 m 21 3700 Black Legs # 3 6 m 22 3880

23 4290 LX 3 20 Pre-Wired Circuits 24 4470 25 4650 26 4830 Tab Rail # 1 Black Tabs 6m Drop 27 5010 28 5190 29 5370 Black Border # 3 3 m 30 5550 Black Legs # 4 6 m 31 5730 32 5910 LX 4 20 Pre-Wired Circuits 33 6090 34 6270 35 6450 36 6630 37 6810 LX 4B Auxiliary LX - Scaff pipe off chain 38 6990 Tab Rail # 2 39 7170 Black Border # 4 3m 40 7350 Black Legs # 5 6 m OP pan 3 x LX Ladders OP 42 7710 PS pan 3 x LX Ladders PS 44 8070 Cyc 5.5m Front/Rear Projection Black PVC 43 31 43

Blue 15 3 14 2 13 1 Blue 42 42 Red Cool Warm Cool Warm Cool Warm Red

41 38 37 34

44 40 39 36 35 44 Gr/Yel Gr/Yel

18 6 17 5 16 4 45 32 45 Gr/Yel CoolWarm Cool Warm CoolWarm Gr/Yel 54 Bl 48 Rd Rd 48 Bl 54

57 Am 51 Gr Gr 51 Am 57

33 21 9 20 8 19 7 46 46 Gr/Yel CoolWarm Cool Warm CoolWarm Gr/Yel 55 Bl 49 Rd Rd 49 Bl 55

58 Am 52 Gr Gr 52 Am 58

BL BL BL

24 12 27 23 26 11 25 22 10 47 47 Gr/Yel CoolWarm Cool Warm CoolWarm Gr/Yel

BL BL BL

67 65 63 61 30 66 64 62 60 29 66 64 62 60 28 67 65 63 61 Am Bl Gr Rd Am Bl Gr Rd Am Bl Gr Rd Am Bl Gr Rd

56 Bl 50 Rd Rd 50 Bl 56

59 Am 53 Gr Gr 53 Am 59

While we aim to maintain this design, it is subject to change based on the requirements of surrounding performances To ensure your requirements are met, please confirm them with our Technical Manager well in advance Theatre Royal Standard Lighting Channel List

Left and right are listed as relative to the operating position. Basic colours listed below, these change as required. Please discuss with the technical manager if you would like to request we supply a particular palette.

Dim Ch Name / Focus Position Colour Fixture Notes 1 Front light DS L FOH 2 warm tint 1200 PC 2 Front light DS C FOH 2 warm tint 1200 PC 3 Front light DS R FOH 2 warm tint 1200 PC 4 Front light D-MS L LX1 warm tint 1200 7” Fresnel 5 Front light D-MS C LX1 warm tint 1200 7” Fresnel 6 Front light D-MS R LX1 warm tint 1200 7” Fresnel 7 Front light M-US L LX2 warm tint 1200 7” Fresnel 8 Front light M-US C LX2 warm tint 1200 7” Fresnel 9 Front light M-US R LX2 warm tint 1200 7” Fresnel 10 Front Light US L LX3 warm tint 1200 7” Fresnel 11 Front Light US C LX3 warm tint 1200 7” Fresnel 12 Front Light US R LX3 warm tint 1200 7” Fresnel 13 Front light DS L FOH 2 cool tint 1200 PC 14 Front light DS C FOH 2 cool tint 1200 PC 15 Front light DS R FOH 2 cool tint 1200 PC 16 Front light D-MS L LX1 cool tint 1200 7” Fresnel 17 Front light D-MS C LX1 cool tint 1200 7” Fresnel 18 Front light D-MS R LX1 cool tint 1200 7” Fresnel 19 Front light M-US L LX2 cool tint 1200 7” Fresnel 20 Front light M-US C LX2 cool tint 1200 7” Fresnel 21 Front light M-US R LX2 cool tint 1200 7” Fresnel 22 Front Light US L LX3 cool tint 1200 7” Fresnel 23 Front Light US C LX3 cool tint 1200 7” Fresnel 24 Front Light US R LX3 cool tint 1200 7” Fresnel 25 Back Light DS L LX3 as suits 1200 7” Fresnel 26 Back Light DS C LX3 as suits 1200 7” Fresnel 27 Back Light DS R LX3 as suits 1200 7” Fresnel 28 Back Light US L LX4 as suits 1200 7” Fresnel 29 Back Light US C LX4 as suits 1200 7” Fresnel 30 Back Light US R LX4 as suits 1200 7” Fresnel 31 DS C Spot : Front light FOH 2 o/w 14/35 Pacific 32 DS C Spot : Toplight LX1 as suits 14/35 Pacific 33 DS C Spot : Back light LX 2 as suits 14/35 Pacific 34 Spotlight Special 1 : Where required FOH 1 o/w 14/35 Pacific 35 Spotlight Special 2 : Where required FOH 1 o/w 14/35 Pacific 36 Spotlight Special 3 : Where required FOH 1 o/w 14/35 Pacific 37 Spotlight Special 4 : Where required FOH 1 o/w 14/35 Pacific 38 Spotlight Special 5 : Where required FOH 1 o/w 14/35 Pacific 39 Spotlight Special 6 : Where required FOH 1 o/w 14/35 Pacific 40 Spotlight Special 7 : Where required FOH 1 o/w 14/35 Pacific 41 Spotlight Special 8 : Where required FOH 1 o/w 14/35 Pacific Dim Ch Name / Focus Position Colour Fixture Notes 42 Curtain Warmer / Front colour FOH 2 Blue Par 64 Paired L+R 43 Curtain Warmer / Front colour FOH 2 Red Par 64 44 Forest Dapple: Quarter cross DS FOH 1 Yellow/Green Split 23/50 Pacific Leafy Breakup Gobos Paired L+R 45 Forest Dapple: Quarter cross D-MS LX 1 Yellow/Green Split 23/50 Pacific 46 Forest Dapple: Quarter cross M-US LX 2 Yellow/Green Split 23/50 Pacific 47 Forest Dapple: Quarter cross US LX 3 Yellow/Green Split 23/50 Pacific 48 DS Top side light DS Ladders Red Par 64 Paired L+R Sides 49 MS Top side light MS Ladders Red Par 64 50 US Top side light US Ladders Red Par 64 51 DS Top side light DS Ladders Green Par 64 52 MS Top side light MS Ladders Green Par 64 53 US Top side light US Ladders Green Par 64 54 DS Top side light DS Ladders Blue Par 64 55 MS Top side light MS Ladders Blue Par 64 56 US Top side light US Ladders Blue Par 64 57 DS Top side light DS Ladders Amber Par 64 58 MS Top side light MS Ladders Amber Par 64 59 US Top side light US Ladders Amber Par 64 60 Cyc : colour 1 Inside LX 4 Red + silk 1000w Cyc Paired as inside / outside 61 Cyc : colour 1 Outside LX 4 Red + silk 1000w Cyc 62 Cyc : colour 2 Inside LX 4 Green + silk 1000w Cyc 63 Cyc : colour 2 Outside LX 4 Green + silk 1000w Cyc 64 Cyc : colour 3 Inside LX 4 Blue + silk 1000w Cyc 65 Cyc : colour 3 Outside LX 4 Blue + silk 1000w Cyc 66 Cyc : colour 4 Inside LX 4 Amber + silk 1000w Cyc 67 Cyc : colour 4 Outside LX 4 Amber + silk 1000w Cyc 68 Spare 69 Spare 70 Spare 71 Spare 72 Spare 73 Spare 74 Spare 75 Spare 76 Spare 77 Spare 78 Spare Wayline Patch-points Patch bay is a hard hard patch IEC system Excluding the 5 Stage bar weilands, all points are standard 10A

Patch Number Description / Location Circuits Standard Usage

1 to 20 Auditorium Roof Front 20 FOH Trusses

21 to 40 Auditorium Roof Centre 20 FOH Trusses

41 to 60 No 1 Stage Bar (Weiland) 20 LX 1

61 to 80 No 2 Stage Bar (Weiland) 20 LX 2

81 to 100 No 3 Stage Bar (Weiland) 20 LX 3

101 to 120 No 4 Stage Bar (Weiland) 20

121 to 140 No 5 Stage Bar (Weiland) 20 LX 4

141 to 144 Rear Of Dress Circle 4

145 to 152 Spare 8

153 to 158 OP Royal Box 6

159 to 164 PS Royal Box 6

165 to 168 Spare 4

169 to 172 Spare 4

173 to 176 PS Orchestra Pit 1 4

177 to 180 PS Orchestra Pit 2 4

181 to 184 OP Orchestra Pit 1 4

185 to 188 OP Orchestra Pit 2 4

189 to 194 OP Gallery 1 (DS) 6 OP Ladder 1

195 to 200 PS Gallery 1 (DS) 6 PS Ladder 1

201 to 206 OP Gallery 2 6 OP Ladder 2

207 to 212 PS Gallery 2 6 PS Ladder 2

213 to 218 OP Gallery 3 6

219 to 224 PS Gallery 3 6

225 to 230 OP Gallery 4 (US) 6 OP Ladder 3

231 to 236 PS Gallery 4 (US) 6 PS Ladder 3

237 to 242 OP Downstage Floor 6

243 to 248 PS Downstage Floor 6

249 to 254 OP Upstage Floor 6

255 to 260 PS Upstage Floor 6

Any electrical equipment brought in must display 260a current safety test tag FLY FLOOR

WEIGHT GALLERY (NORTH SIDE ONLY)

AUDITORIUM CROSS-OVER ROOF SPACE

REHEARSAL ROOM UPPER GALLERY

TOP OF PROSCENIUM ARCH NORTH SIDE STAIR WELL SHOWN DOTTED UPPER CIRCLE

WARDROBE BOX

STAGE BACK STAGE

FOYER SHOP / TICKETS AUDITORIUM

ORCHESTRA PIT BAND ROOM THEATRE ROYAL - NELSON www.venueweb.co.nz - 08/10 based on drawings ex Palmer&Palmer, Nelson 0 132 4 5 10 metres THEATRE ROYAL - NELSON www.venueweb.co.nz - 08/10 based on drawings ex Palmer&Palmer, Nelson 0 132 4 5 10 metres

SEAT WHB SINK WC ACCESSIBLE ACCESSIBLE MALE WC FEMALE WC WC WASH AREA BAR STORE WC 87 6 5 4321 ACCESSIBLE WC ROLLER SCREEN OVER HVAC RISER

RISER CLEANER CLEANER

ACCESSIBLE STAGE STAIR SPRINKLER SHOWER ROOM UP 1234 65 1234 1098765

LIFT BAR FOYER

87654 HANGING BASEMENT STAIR HANGING

TICKET SALES SEAT DRESSING 1 DRESSING 2 SEAT RL 15.435 KERB RUTHERFORD STREET RUTHERFORD

STAGE SHOP ENTRY FOYER PIT COUNTER BACK STAGE RL 16.385 REMOVABLE REMOVABLE SEATS TOP-HUNG SLIDING DOOR SLIDING TOP-HUNG RL RL 16.135

FIRE OFFICE DOOR CARPET RL 16.385 4 3 AUDITORIUM 2 RL 15.435 14 13 12 11 10 1

654321

54321

ACCESSIBLE RAMP NORTH FOYER 54321 1:12 GRADIENT DIMMER ROOM

10 9 8765432 1 FIRE DOOR STORE RL 15.385

UP COUNTER WEIGHT VOID ABOVE LOADING BAY THEATRE ROYAL - NELSON www.venueweb.co.nz - 08/10 based on drawings ex Palmer&Palmer, Nelson 0 132 4 5 10 metres

13 12 11 4 123

1415 16 1817 WC HVAC RISER MECHANICAL PLANT ROOM RL 19.585 ROOF

RISER

FIRE 13121110987654321 DOOR SH PASSAGE STAIR TO UPPER LEVEL RL 18.910 CBD

19181716151413121110987654

RL 19.360 SOUTH LANDING BOX HANGING HANGING

321 SEAT SEAT RL 19.585 DRESSING 3 DRESSING 4

VOID ABOVE STAGE

VOID ABOVE AUDITORIUM

BALCONY

RL 19.475 WARDROBE

FIRE DOOR

RL 19.360 NORTH LANDING 54321 8

BOX RL 18.910 9 20 19 18 17 16 15 14 13 12 18 17 16 15 14 13 12 11 10 LADDER TO UPPER 19.585 RL UP COUNTER WEIGHT VOID STAIR FROM FOYER MAIN SWITCHBOARD GALLERY 321