Theatre Royal Technical Specifications
Total Page:16
File Type:pdf, Size:1020Kb
! ! ! ! ! ! ! ! ! ! ! ! Theatre Royal Nelson Technical Specifications ! ! ! ! ! ! ! ! Technical Manager Theatre Manager !JR Richardson Janice Marthen 027 461 6458 (03) 548 3840 (ext 3) (03) 548 3840 (ext 1) [email protected] [email protected] www.theatreroyalnelson.co.nz Any electrical equipment brought in must display a current safety test tag Stage Dimensions !Setting line is the upstage edge of the proscenium Stage Surface Flat painted ply-wood Stage height 890mm Proscenium arch 8100mm wide x 4900mm high Edge to setting line 1230mm Stage depth 8540 mm (Setting line to face of upstage wall) !Stage weight loading max 500kg per square metre Wing Dimensions Wing-space OP 6500mm to wall Wing-space PS 2000mm to Fly controls Stage floor to underside gallery walkway 5000mm Stage floor to gallery handrail 6800mm !Gallery handrail height 1000mm Dock / Stage Access Dimensions Loading dock door: 2750mm wide x 2800mm high !Upstage scene door: 3300mm wide x 2700mm high Dock is set 1250mm up, and 2300mm back from closest sealed vehicle access due to a 300mm high landing for the adjoining pedestrian entrance. !Vehicle access via Vanguard Street, driveway north of Cory’s Electrical Fly Tower Specifications Batten in-dead 1300 mm (top of batten) Batten out-dead 10450 mm (top of batten) Maximum drift 9150 mm !Stage floor to grid 10670 mm (underside) Battens are 75 x 50 mm RHS Batten length 10600 mm Suspension wires 4x 6mm wire rope, 1600mm & 4800mm from center Cradle Slaves 2x units 2-5 line span Max distributed load per batten is 400 Kg !Max point load is 200 Kg Orchestra Pit A section of the auditorium floor can be removed in two configurations exposing an MD or the full pit !without disturbing the seating plan. Contact the house technician to discuss options. Pit Depth 1500mm below auditorium floor, 2400 below stage Orchestra Pit room 3500mm x 8000mm - Concave front wall Band Room 6800mm x 8000mm Pit opening Full 8000mm wide !Pit opening Partial 1100mm wide x 1500mm deep (to stage front) ! Any electrical equipment brought in must display a current safety test tag Masking 1x House curtain Red velvet, overlapped split 5x Pairs of black legs 6m with returns 4x Black borders : 3m drop 1x Black tabs 6m drop 2x Tab Tracks 1x Black ground-row 400mm High 1x Cyc Screen Black front or rear projection PVC !2x Cinema Screens 1x White, 1x Silver (extra labour required to install, please discuss options) Sound System 4x QSC K12 Speakers 2x EAW VR-62 front fill speakers run off a QSC USA450 amplifier 2x Peavey Q118 subs run of a Samson SX3200 amplifier. 1x DBX Driverack 260 1x Allen & Heath ZED16 - 8Mic Pre mixer 3x 12/4 XLR Snakes 10x XLR Returns to Amp rack 2x Stage fill JBL M825 speakers run off a Phonic amp 1x TASCAM CD-1U CD player 2x SM58 microphones and stands Front fill speakers are mounted above the proscenium arch providing high frequency fill to the first few rows in the stalls. K12s are flown in two pairs; one from each FOH truss. FOH 1 pair is tilted to cover most of the stalls. FOH 2 pair is flown flat and covers the back of the stalls and the balcony. Subs are positioned on the auditorium floor, either side of the proscenium arch. The system is tuned via a Driverack 260. K12s are run in stereo pairs, channels 1 through 4, Subs and Front Fill are mono, on channels 5 and 6 respectively. Drive-rack settings are locked with access at the discretion of the Theatre Royal Technical Manager and BB Sound. This system provides excellent coverage throughout the auditorium to 100dBa and is suitable for theatre, music theatre, dance playback and concert applications. Power Standard 10A and technical earth 10A (for Audio) outlets are located throughout the facility On Stage 5x 40A Outlets 1x 40A Outlet (Technical Earth) 2x 63A Outlets 1x 300A Lighting Powerlock 1x 200A Sound Powerlock Operating Position 1x 40A Outlets 1x 40A Outlet (Technical Earth) Loading dock 1x 63A Outlet Gallery Level 3x 40A Outlets Fly Level 1x 40A Outlets Rehearsal Room 2x 40A Outlets Auditorium ceiling 2x 40A Outlets Band Room 1x 40A Outlets 1x 40A Outlet (Technical Earth) Any electrical equipment brought in must display a current safety test tag !Rigging & Hanging Positions FOH 1: 9m alloy box truss, fixed, 60° to setting line 5.4m high, 3.1m from setting line (60°) FOH 2: 9m alloy box truss on 2x 500kg motors 5.4m high, 4.7m from setting line (45°) Arch Bar: 8m Ladder bar on 2x chain hoists ! 120mm Downstage of curtain - Front fill speakers installed Overhead: 4x Internally wired bars, 20 circuits each, counterweight flown 2x Auxiliary scaffold pipe bars, counterweight flown ! 3x Ladders on both PS & OP Pan Bars, counterweight flown !Floor: 8 Baseplates and a range of scaffold pipe and clips Access: Genie-lift and a variety of ladders for focussing etc. ! Lighting System Lamp-stock: 24x Selecon Fresnel 1200 with B/Doors 6x Selecon PC 1200 with B/Doors 12x Pacific 14/35 13x Pacific 23/50 30x Par 64 Can (CP62 lamp) 4x 4 Way Selecon 1000W Cyc Units 2x Mini Fresnel 650W 12x A sized Gobo Holder 10x B sized gobo holder ! 11x Iris for Pacific !Extra lamps can sourced for hire locally, please advise if you require. Control Equipment 1x 120 Channel Theatrelight Cuemaster Control Desk 64x 2.4KW Dimmers DMX (Theatrelight PID II) 1x 12channel Theatrelight DMX Dimmer pack 260x Waylines to stage, gallery, fly floor and auditorium 1x IEC Based patch bay ! 1x 10 Channel DMX splitter + way-lines to stage, gallery and auditorium House Lights All auditorium lights are on an independent dimming system with controllers at the SM panel, Foyer !and the standard operating position. Standard Configuration Our standard lighting configuration provides the following (plan attached) - Full stage warm and cool front light - Full stage back-light - Full Stage Break-up Gobo - Red and Blue Front Colour - Four colour of side-light - 8x Spotlight specials - 4 Colour Cyc wash Any electrical equipment brought in must display a current safety test tag Backstage Dressing Rooms 4x 2 per stage & 2per 2nd level. Avg. dimension 5.5m x 2.7m Each with wide, lit makeup mirrors. Bench and swivel seating. Rehearsal Room 8m x 11.2m Carpeted room with attached kitchenette on the 3rd level Toilets 5x 2per Stage level, 3per 2nd level Shower 2x 1per Stage and 2nd level Kitchenette 2x 1per Stage & 3rd level w/ bench, sink, kettle microwave & fridge Other Facilities Dressing rooms 4x (2 stage level, 2 2nd level) Laundry 1x Washing Machine & Dryer 2x Iron & Board Staging 7x Wooden risers 2400mm x 900mm x 290mm (h) Piano Ehrbar 8 foot Grand Piano - Stage level only. Tuning available on request Internet Direct fibre connection and wifi password available to occupants Data Cabling CAT6e throughout building terminating in patch bay in dimmer room Comms 1x Clear-Com Base-station 3x Clear-Com Belt Units 4x Clear-Com Head-units Patch points throughout building Spotting light Yes Stage monitoring Camera fixed - 1 monitor per: dressing room, PS wing + 2x FOH Wheelchair lift Links Wheelchair accessible Foyer to Stage and Pit levels Wheelchair facilities 1x Bathroom, 1x Shower on stage level Blue Lights Throughout back of house Security Magnetic locking to FOH- engaged during performance hours or as required. Keys issued to core crew. Pin-coded backstage door. Air-conditioning Discrete programmable temperature control of the auditorium and stage. Fresh air supply to all back of house areas. First Aid First Aid is located in the Dimmer Room Fire Safety Heat Sensor based fire alarm, sprinkler system, smoke doors and Fire Extinguishers located throughout the building Smoke/Particle Alarm No !Fire Curtain No Any electrical equipment brought in must display a current safety test tag Third Party Providers We may not have everything you need in-house, but we do have amazing relationships with our preferred local hire companies. Please talk to us if you would like help sourcing any of the following: Lighting Lamp fixtures : Generics, UV, LED or Intelligent Follow-spot Dimmers Control Desks Rigging Truss or Scaffold Floor-based or Flown Staging Rostra, Risers, Platforms and stairs Dressing Drapery Gauze Cloth Tables / Chairs Decor & Design Flying Specialised crew and equipment for the flying of scenery or persons Sound Microphones and DI’s Mixing Desks: Analogue or Digital Outboard : Effects or Processing Monitoring / Extra Speakers Recording Solutions Back-line Projection Presentation or Cinema Style Projection and Screen Solutions Atmospheric Effects Smoke or Haze Machines Pyrotechnic Effects Certified theatrical pyro-technicians Firearms Licensed providers of blank stage firearms Special Effects Laser Effects Dry Ice Any electrical equipment brought in must display a current safety test tag Theatre Royal Nelson : Standard House Hanging Plot Setting line = Upstage edge of proscenium Line set U/S of Set Line (mm) Item Height Notes 1 100 House Curtain 5.5m Red Velvet, overlapped split 2 280 Black Legs #1 6m 3 460 4 640 LX 1 20 Pre-Wired Circuits 5 820 6 1000 7 1180 8 1360 9 1540 Black Border # 1 3 m 10 1720 Black Legs # 2 6 m 11 1900 12 2080 13 2260 LX 2 20 Pre-Wired Circuits 14 2440 15 2620 16 2800 17 2980 18 3160 19 3340 20 3520 Black Border # 2 3 m 21 3700 Black Legs # 3 6 m 22 3880 23 4290 LX 3 20 Pre-Wired Circuits 24 4470 25 4650 26 4830 Tab Rail # 1 Black Tabs 6m Drop 27 5010 28 5190 29 5370 Black Border # 3 3 m 30 5550 Black Legs # 4 6 m 31 5730 32 5910 LX 4 20 Pre-Wired Circuits 33 6090 34 6270 35 6450 36 6630 37 6810 LX 4B Auxiliary LX - Scaff pipe off chain 38 6990 Tab Rail # 2 39 7170 Black Border # 4 3m 40 7350 Black Legs # 5 6 m OP pan