Facebook Server Intel Motherboard V3.0

Total Page:16

File Type:pdf, Size:1020Kb

Facebook Server Intel Motherboard V3.0 Facebook Server Intel Motherboard v3.0 Author: Jia Ning, Engineer, Facebook Contents Contents .......................................................................................................................................... 2 1 Scope ......................................................................................................................................... 5 2 Overview ................................................................................................................................... 5 2.1 License ............................................................................................................................. 5 3 Efficient Performance Motherboard v3 Features ..................................................................... 6 3.1 Block Diagram .................................................................................................................. 6 3.2 Placement and Form Factor ............................................................................................ 6 3.3 CPU and Memory ............................................................................................................. 7 3.4 Platform Controller Hub .................................................................................................. 8 3.5 Printed Circuit Board Stackup (PCB) ................................................................................ 8 4 Basic Input Output System (BIOS) ........................................................................................... 10 4.1 BIOS Chip ....................................................................................................................... 10 4.2 BIOS Source Code .......................................................................................................... 10 4.3 BIOS Feature Requirements .......................................................................................... 10 5 Baseboard Management Controller (BMC) ............................................................................. 14 5.1 Management Network Interface ................................................................................... 14 5.2 Local Serial Console and Serial-Over-LAN (SOL) ............................................................ 14 5.3 Graphic and GUI ............................................................................................................. 15 5.4 Remote Power Control and Power Policy ...................................................................... 15 5.5 Port 80 POST .................................................................................................................. 15 5.6 Power and System Identification LED ............................................................................ 15 5.7 Platform Environment Control Interface (PECI) ............................................................. 16 5.8 Power and Thermal Monitoring and Power Limiting ..................................................... 16 5.9 Sensors .......................................................................................................................... 16 5.10 System Event Log (SEL) ................................................................................................ 21 5.11 Fan Speed Control in BMC ........................................................................................... 23 5.12 BMC Firmware Update ................................................................................................ 24 5.13 BMC Update: Dual PCH flash ....................................................................................... 24 5.14 BMC Update Complex Programmable Logic Device (CPLD) ........................................ 26 6 Thermal Design Requirements ................................................................................................ 26 2 November 5, 2013 Open Compute Project Intel Motherboard Hardware v3.0 6.1 Data Center Environmental Conditions ......................................................................... 26 6.2 Server Operational Conditions ...................................................................................... 27 6.3 Thermal Kit Requirements ............................................................................................. 28 7 Midplane Interface and Midplane ........................................................................................... 29 7.1 Connector Modules ....................................................................................................... 29 7.2 Pin Definition ................................................................................................................. 29 7.3 Population options ........................................................................................................ 33 7.4 Midplane for Open Rack V1 ........................................................................................... 34 8 Motherboard Power system ................................................................................................... 35 8.1 DC Cable Assembly ........................................................................................................ 35 8.2 Input Voltage ................................................................................................................. 35 8.3 Hot Swap Controller (HSC) Circuit ................................................................................. 35 8.4 CPU Voltage Regulator (VR) ........................................................................................... 36 8.5 DIMM Voltage Regulator ............................................................................................... 37 8.6 Voltage Regulator Module Design Guideline ................................................................. 37 8.7 Hard Drive Power .......................................................................................................... 38 8.8 System VRM Efficiency .................................................................................................. 39 8.9 Power On ....................................................................................................................... 39 9 I/O System ............................................................................................................................... 40 9.1 PCIe* x24 Slot Connector/Riser Card ............................................................................. 40 9.2 DIMM Connector ........................................................................................................... 41 9.3 PCI-E Mezzanine Card .................................................................................................... 41 9.4 Network ......................................................................................................................... 43 9.5 USB ................................................................................................................................ 43 9.6 SATA ............................................................................................................................... 44 9.7 Next Generation Form Factor (NGFF) Connectors ......................................................... 44 9.8 Debug Header ................................................................................................................ 44 9.9 Switches and LEDs ......................................................................................................... 47 9.10 Fan Connector ............................................................................................................. 49 9.11 TPM Connector and Module ....................................................................................... 49 10 Mechanical .............................................................................................................................. 51 10.1 Shelf ............................................................................................................................. 51 10.2 Tray and Sled ............................................................................................................... 51 10.3 PCIe and HDD bracket ................................................................................................. 52 10.4 Fixed Locations ............................................................................................................ 52 http://opencompute.org 3 10.5 PCB Thickness .............................................................................................................. 52 10.6 Heat Sinks and Independent Loading Mechanism (ILM) ............................................. 52 10.7 Silk Screen ................................................................................................................... 52 10.8 DIMM Connector Color ............................................................................................... 52 10.9 PCB Color ..................................................................................................................... 52 11 Environmental Requirements ................................................................................................. 53 11.1 Vibration and Shock .................................................................................................... 53 12 Prescribed Materials ............................................................................................................... 54 12.1 Disallowed
Recommended publications
  • Ultrascale Architecture PCB Design User Guide (UG583)
    UltraScale Architecture PCB Design User Guide UG583 (v1.21) June 3, 2021 Revision History The following table shows the revision history for this document. Date Version Revision 06/03/2021 1.21 Chapter 1: Added Recommended Decoupling Capacitor Quantities for Zynq UltraScale+ Devices in UBVA530 Package. In Table 1-13, added row for 1.0 µF. Chapter 2: Added PCB Routing Guidelines for LPDDR4 Memories in High-Density Interconnect Boards. 02/12/2021 1.20 Chapter 1: Added XCKU19P to Table 1-4. Added XCVU23P-FFVJ1760 to Table 1-5. Added XCVU57P-FSVK2892 to Table 1-7. Added VU57P to Table 1-8. Updated first sentence in VCCINT_VCU Plane Design and Power Delivery. Chapter 2: Updated item 13 in General Memory Routing Guidelines. Updated first paragraph in PCB Guidelines for DDR4 SDRAM (PL and PS). Added Routing Rule Changes for Thicker Printed Circuit Boards. Chapter 3: Added XCZU42DR to Table 3-1. Added paragraph about clock forwarding capability in Gen 3 RFSoC devices to Recommended Clocking Options. Added Table 3-11. Updated Powering RFSoCs with Switch Regulators. Added Power Delivery Network Design for Time Division Duplex. Chapter 4: Added bullet about device without DQS pin to DDR Mode (100 MHz). In SD/SDIO, added note about external pull-up resistor after fifth bullet, and added two bullets about level shifters. Chapter 11: Replaced I/O with I/O/PSIO in Unconnected VCCO Pins. 09/02/2020 1.19 Chapter 1: In Table 1-4, updated packages for XQKU5P and XCVU7P, added row for XCVU23P-VSVA1365, and updated note 3. In Table 1-9, updated packages for XCZU3CG, XCZU6CG, XCZU9CG, XCZU3EG, XCZU6EG, XCZU9EG, and XCZU15EG.
    [Show full text]
  • Parasitic Component Analysis and Acoustic Noise Evaluation in Voltage Regulator Modules (Vrms)
    Parasitic Component Analysis and Acoustic noise evaluation in Voltage Regulator Modules (VRMs) A THESIS SUBMITTED TO THE FACULTY OF UNIVERSITY OF MINNESOTA BY PRANIT JANNAWAR IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF MASTER OF SCIENCE Ned Mohan, Adviser June, 2015 © Pranit Jannawar 2015 Acknowledgements I would like to thank my adviser Prof. Ned Mohan for his support and advice. I appreciate his patience in guiding me throughout the period. I have learnt what kind of effort is put into the research and what kind of attitude is required to address a technical issue. I would like to mention the efforts of my fellow mates in the lab who helped me obtaining components and hardware in timely manner. Finally, I express my gratitude to my parents for their emotional support and encouragement. i Abstract Stable and regulated supply voltage has been an important topic of discussion in a consumer electronic products. Every chip and device requires specified voltages with small margins. Voltage regulated modulators (VRMs) have always been proven to provide a solution to this problem. Building a power stage using point of load method helps overcome variability issue in the signal but introduces a converter with lot of supporting components. Multiple combination of capacitors and resistors of different material composition are required to obtain an optimal design for the product. PCB parasitic comes into play and due to high current slew rate physical stress builds up in the caps which tend to come out in form of acoustic noise. This thesis deals with such issues which can improve the product quality but keeping the cost low by utilizing and analyzing components the proper way.
    [Show full text]
  • Xeon™ Processor Voltage Regulator Down (VRD) Design Guidelines
    ® Dual Intel® Xeon Processor Voltage Regulator Down (VRD) Design Guidelines July 2003 Order Number 298644-003 Dual Intel® Xeon Processor Voltage Regulator Down (VRD) Guidelines THIS DOCUMENT AND RELATED MATERIALS AND INFORMATION ARE PROVIDED "AS IS" WITH NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NON- INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS, OR ANY WARRANTY OTHERWISE ARISING OUT OF ANY PROPOSAL, SPECIFICATION, OR SAMPLE. INTEL ASSUMES NO RESPONSIBILITY FOR ANY ERRORS CONTAINED IN THIS DOCUMENT AND HAS NO LIABILITIES OR OBLIGATIONS FOR ANY DAMAGES ARISING FROM OR IN CONNECTION WITH THE USE OF THIS DOCUMENT. Intel products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications. Intel Corporation may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked reserved or undefined. Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. This document contains information on products in the design phase of development. Do not finalize a design with this information. Revised information will be published when the product is available.
    [Show full text]
  • Analysis of Low Voltage Regulator Efficiency Based
    ANALYSIS OF LOW VOLTAGE REGULATOR EFFICIENCY BASED ON FERRITE INDUCTOR by MRIDULA KOTHAKONDA A THESIS Submitted in partial fulfillment of the requirements for the degree of Master of Science in the Department of Electrical and Computer Engineering in the Graduate School of The University of Alabama TUSCALOOSA, ALABAMA 2010 Copyright Mridula Kothakonda 2010 ALL RIGHTS RESERVED ABSTRACT Low voltage regulator based on ferrite inductor, using single- and two-phase topologies, were designed and simulated in MATLAB. Simulated values of output voltage and current were used to evaluate the buck converter (i.e., low voltage regulator) for power efficiency and percentage ripple reduction at frequencies between 1 and 10 MHz with variable loads from 0.024 to 4 Ω. The parameters, such as inductance of 20 nH, quality factor of 15 of fabricated ferrite inductor and DC resistance (DCR) of 8.3 mΩ, were used for efficiency analysis of the converter. High current around 40 A was achieved by the converter at low load values. Low output voltage in the range of 0.8-1.2 V was achieved. The simulated results for the single- and two- phase converter were compared for maximum efficiency and lowest ripple in output voltage and current. The maximum efficiency of 97 % with load of 0.33 Ω and the lowest ripple current of about 2.3 mA were estimated for the two-phase converter at 10 MHz. In summary, the two- phase converter showed higher efficiency and lower ripple voltage and current than those of the single-phase converter. In addition, the efficiency of single- and two-phase converters based on ferrite inductor was compared to single- and two-phase converters based on air-core inductor.
    [Show full text]
  • Pentium® II Xeon™ Processor Power Distribution Guidelines
    E AP-828 APPLICATION NOTE Pentium® II Xeon™ Processor Power Distribution Guidelines June 1998 Order Number: 243772-001 5/28/98 3:57 PM 24377201.DOC INTEL CONFIDENTIAL (until publication date) Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The Pentium® II Xeon™ processor may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an ordering number and are referenced in this document, or other Intel literature, may be obtained by calling 1-800-548-4725 or by visiting Intel’s website at http://www.intel.com Copyright © Intel Corporation 1998.
    [Show full text]
  • Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 10.2
    Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 10.2 Design Guidelines March 2005 Document Number: 306760-001 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. Intel® Xeon™ processor and 64-bit Intel® Xeon™ processor MP may contain design defects or errors known as errata that may cause the product to deviate from published specifications. Current characterized errata are available on request. Intel, Intel Xeon, Pentium and the Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. ∆ Intel processor numbers are not a measure of performance. Processor numbers differentiate features within each processor family, not across different processor families.
    [Show full text]
  • Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 11.1
    Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 11.1 Design Guidelines September 2009 Reference Number: 321736 Revision: 002 Notice: This document contains information on products in the design phase of development. The information here is subject to change without notice. Do not finalize a design with this information. INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The Intel Xeon Processor 5500 Series, processors in the Intel Xeon 5500 Platform platforms may contain design defects or errors known as errata, which may cause the product to deviate from published specifications. Current characterized errata are available upon request. No computer system can provide absolute security under all conditions. Intel® Trusted Execution Technology (Intel® TXT) requires a computer system with Intel® Virtualization Technology, an Intel TXT-enabled processor, chipset, BIOS, Authenticated Code Modules and an Intel TXT-compatible measured launched environment (MLE).
    [Show full text]
  • Investigation of Alternative Power Architectures for CPU Voltage Regulators
    Investigation of Alternative Power Architectures for CPU Voltage Regulators Julu Sun Dissertation submitted to the Faculty of the Virginia Polytechnic Institute and State University in partial fulfillment of the requirements for the degree of Doctor of Philosophy in Electrical Engineering Fred C. Lee, Chairman Dusan Boroyevich Ming Xu William T. Baumann Carlos T.A. Suchicital Elaine P. Scott November 22nd, 2008 Blacksburg, Virginia Keywords: two-stage, voltage regulator, high power density, high efficiency Investigation of Alternative Power Architectures for CPU Voltage Regulators Abstract Since future microprocessors will have higher current in accordance with Moore’s law, there are still challenges for voltage regulators (VRs). Firstly, high efficiency is required not only for easy thermal management, but also for saving on electricity costs for data centers, or battery life extension for laptop computers. At the same time, high power density is required due to the increased power of the microprocessors. This is especially true for data centers, since more microprocessors are required within a given space (per rack). High power density is also required for laptop computers to reduce the size and the weight. To improve power density, a high frequency is required to shrink the size of the output inductors and output capacitors of the multi-phase buck VR. It has been demonstrated that the output bulk capacitors can be eliminated by raising the VR control bandwidth to around 350kHz. Assuming the bandwidth is one-third of the switching frequency, a VR should run at 1MHz to ensure a small size. However, the efficiency of a 12V VR is very poor at 1MHz due to high switching losses.
    [Show full text]
  • Power Systems
    Power Systems Voltage regulators for the 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D Power Systems Voltage regulators for the 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 65, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. This edition applies to IBM Power Systems servers that contain the POWER7 processor and to all associated models. © Copyright IBM Corporation 2010, 2013. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Safety notices .................................v Voltage regulator modules for the 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D ..................................1 Installing the 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D voltage regulator module ....2 Removing the 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D voltage regulator module ....5 Replacing the 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D voltage regulator module ....7 Common procedures for installable features .........................8 Before you begin .................................8 Identifying a part ................................11 Control panel LEDs...............................11 Identifying a failing part in an AIX system or logical partition ................13
    [Show full text]
  • The Memrowave
    The Memrowave A UCF Senior Design Project Fall 2014 Group 31 Winston Todd Jack Gulick Joseph Serritella Darren Armstrong Table of Contents Table of Contents ii List of Figures iv List of Tables vi 1 Executive Summary 1 2 Project Description 2 2.1 Project Motivation 2 2.2 Objectives 4 2.2.1 Automatic Timer 4 2.2.2 Food Product Database 6 2.3 Project Requirements and Specifications 9 2.3.1 Automatic Timer and Power Level 9 2.3.2 Local Product Database with Web Update 9 2.3.3 Touch Screen Interface 11 2.3.4 Barcode and QR Code Reader 12 2.3.5 SMS Notifications 12 2.3.6 User Profiles 12 2.3.7 Manual Operation 13 3 Research 13 3.1 Similar Projects and Products 13 3.1.1 Retail and Other Smart Appliances 13 3.1.2 Previous Senior Design Projects 14 3.1.3 Current Microwave Interfaces and Functionality 15 3.2 Relevant Technologies 28 3.2.1 Magnetron Control 29 3.2.2 ARM Microprocessors 34 3.2.3 Computer Vision for Barcodes and QR Codes 35 3.2.4 Output Display Technologies 35 3.2.5 Input Touch Screen Technologies 36 3.2.6 Operating Systems 37 3.2.7 Wi-Fi Interface 38 4 Project Design Details 40 4.1 Initial Design Approaches 40 4.2 Hardware 41 4.2.1 Power Supply 41 4.2.2 Magnetron Controller 47 4.2.3 Miscellaneous Microwave Controller 52 4.2.4 ARM Microprocessor 57 4.2.5 LCD with Capacitive Touch Screen Display 61 4.2.6 Wi-Fi Interface 62 4.2.7 Camera 63 4.3 Software 63 4.3.1 The Android Operating System 64 4.3.2 Drivers, Libraries, Dependencies 64 ii 4.3.3 Microwave Control 64 4.3.4 Barcode and QR Code Software 68 4.3.5 Local Product Database 68
    [Show full text]
  • (VRM) and Enterprise Voltage Regulator-Down (EVRD) 10.0
    R Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 10.0 Design Guidelines July 2005 Document Number: 302731-002 VRM and EVRD 10.0 Design Guidelines R INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL’S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. Intel processors may contain design defects or errors known as errata that may cause the product to deviate from published specifications. Current characterized errata are available on request. Intel, Intel Xeon, Pentium and the Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. ∆ Intel processor numbers are not a measure of performance. Processor numbers differentiate features within each processor family, not across different processor families.
    [Show full text]
  • Intel Storage System SSR212CC
    Intel ® Storage System SSR212CC Technical Product Specification Revision 1.2 Storage Group Technical Marketing Revision History Intel® Storage System SSR212CC TPS Revision History Date Revision Modifications Number May 16, 2006 1.0 Release copy. July 11, 2006 1.1 Added RoHS statement, section 6.2. December 06, 1.2 DDR2 pin number correction 2007 ii Revision 1.2 Intel® Storage System SSR212CC TPS Disclaimers Disclaimers Information in this document is provided in connection with Intel ® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The Intel® Storage System SSR212CC may contain design defects or errors known as errata that may cause the product to deviate from published specifications. Current characterized errata are available on request. Intel system boards contain a number of high-density VLSI and power delivery components that need adequate airflow to cool.
    [Show full text]