F FILTRATION Vacuum Filtration System

Total Page:16

File Type:pdf, Size:1020Kb

F FILTRATION Vacuum Filtration System F FILTRATION Vacuum Filtration System VP-17-LF 30/VP-17-LF 30-SS/VP-17-LF 32/CVP-14-300A, Vacuum Filtration System Pes Funnel Features: No air pollution, maintenance free VP-17-LF 30 All pumps are driven by Piston, no need for 167305-11(22) lubricant, regular oil changes and maintenance; with no oil pollution. The patented spin-lock design The filter holder and waste bottle use a patented spin-lock connection giving a fast and stable installation without clamp. Overflow protection Waste bottle built in spill-proof buoy to keep the filtrate from overflowing when waste bottle is full. Applications: Pes Funnel VP-17-LF 30 is ideal for general filtration in laboratory VP-17-LF 30-SS is ideal for Suspended solid test. VP-17-LF 30-SS VP-17-LF 32 is ideal for filtration requiring the sterilization 167307-11(22) such as microbiology test. CVP-17-300A is ideal for the sample pretreatment of HPLC, GC, AA etc. In microanalysis or the purification of solvents etc. Model VP-17-LF 30 VP-17-LF 30-SS Voltage 110V/60Hz 220V/50Hz 110V/60Hz 220V/50Hz Max. flow rate 21 l/min 18 l/min 21 l/min 18 l/min Max. vacuum 670 mmHg (89.3 kPa) (120 mbar) Capacity (Funnel/Waste bottle) 300ml/1200ml Filter diameter 47mm/50mm Effective filtration area 12.5 cm2 SUS316 Funnel Port thread 8mm Fitting part Material VP-17-LF 32 Filter funnel PES 167306-11(22) Waste bottle PES Funnel support base PP Funnel lid PP Spill-proof buoy PP Filter - Glass Fiber Model VP-17-LF 32 CVP-14-300A Voltage 110V/60Hz 220V/50Hz 110V/60Hz 220V/50Hz Max. flow rate 21 l/min 18 l/min 20 l/min 20 l/min Max. vacuum 670 mmHg (89.3 kPa) (120 mbar) Capacity Glass Funnel (Funnel/Receiver flask) 300ml/1200ml 300ml/1000ml Filter diameter 47mm/50mm 47mm Effective filtration area 12.5 cm2 9.6 cm2 Port thread 8mm CVP-14-300A Fitting part Material 169301-11(22) Filter funnel SUS316 Borosilicate glass Receiver flask PES Borosilicate glass Funnel support base SUS316 Borosilicate glass Clamp - Anodized aluminum Spill-proof buoy PP - Filter MCE - 248 Vacuum Filtration System FILTRATION F BSU-34-LF 30 / BSU-34-LF 32, Vacuum Filtration System Features: PES Funnel compact and safe operation BSU-34 is a unique suction system by combining vacuum BSU-34-LF 30 197401-11(22) source with filtration ware. Its compact design can save more bench space than other traditional models. With a fence-like platform design, it can prevent user’s negligence from tipping over the suction bottle. The patented spin-lock design The filter holder and waste bottle use a patented spin-lock connection giving a fast and stable installation without clamp. Overflow protection Waste bottle built in spill-proof buoy to keep the filtrate from overflowing when waste bottle is full. SUS316 Funnel PES plastic injection (Polyethersulfone) Waste bottle is made of PES which are autoclavable, BSU-34-LF 32 ° 197402-11(22) shatterproof and high temperature (180 C) resistance and steam autoclavable. Applications: Filtration for microbiology test Suspended solid test Vacuum filtration. Model BSU-34-LF 30 BSU-34-LF 32 Voltage 110V/60Hz 220V/50Hz 110V/60Hz 220V/50Hz Max. power (W) 100 80 100 80 Max. current (A) 1.0 0.4 1.0 0.4 Max. vacuum 720 mmHg (95.9 kPa) (53.3 mbar) Max. flow rate 37 l/min 34 l/min 37 l/min 34 l/min Motor rotation 1750 RPM 1450 RPM 1750 RPM 1450 RPM Port thread 8mm Fitting part Material Filter funnel PES (300ml, 47mm/50mm) SUS316 (100mI,47mm/50mm) Waste bottle PES (1200ml) Funnel support base PP (Containing PTFE syringe filter, 25mm, 0.2µm) SUS316 Funnel lid PP - Spill-proof buoy Yes 249 F FILTRATION S.S Manifold MANF-330/630/600/300, Multi-Branch S.S Manifold Features: The whole set is made of SUS316 All parts of MANF-300/600/330/630 manifold are made MANF-330 of SUS316, which offer excellent chemical resistance and can be sterilized by flame, steam and oven etc. The patented spin-lock design The manifold uses a patented spin-lock connection MANF-630 which facilitates fast and stable installation without clamp. Ordering Information Individual control valve 167103-23 Each branch permits individual control. MANF-330, 3 Places Stainless Steel Manifold (without SS funnel). Compatible to different size of funnels 167103-26 MANF-330/630 manifolds are available to fit 100, MANF-630, 6 Places Stainless Steel Manifold 300, 500ml funnel optionally. (without SS funnel). MANF-300/600 manifolds are available to fit 500, 750, 167103-24 1000ml funnel optionally. MANF-331, 3 Places Stainless Steel Manifold Set (Indues 3 pcs of 100ml SS funnel). Applications: 167103-27 Filtration for microbiology test MANF-631, 6 Places Stainless Steel Manifold Set Chemical experiment (Indues 6 pcs of 100ml SS funnel). General liquid filtration . 1000ml 750ml 500ml Optional Funnels: Optional Funnels: 167102-50 167103-61 500ml 300ml 100ml 500ml S.S Funnel 100ml S.S Funnel 167102-75 167103-63 750ml S.S Funnel 167102-99 300ml S.S Funnel 1000ml S.S Funnel MANF-300 167103-65 167110-20 With S.S Funnel+Cover S.S Cover (Available to fit 500ml S.S Funnel MANF-330 With S.S Funnel above-mentioned funnels). Model MANF-330 MANF-630 MANF-300 MANF-600 Number of branch 3 6 3 6 Filter diameter 47mm/50mm 47mm/50mm 47mm/50mm 47mm/50mm Funnel capacity 100ml/300ml/500ml 100ml/300ml/500ml 500ml/750ml/1000ml 500ml/750ml/1000ml Effective filtration area 9.6cm2 9.6cm2 9.6cm2 9.6cm2 Port thread 8mm 8mm 8mm 8mm Dimension (LxWxH) mm 44.5x12.9x12.5 68.5x12.9x12.5 43.5x15x14.5 67.5x15x14.5 Fitting part Material Material Material Material Body SUS316 SUS316 SUS316 SUS316 Control valve SUS316 SUS316 SUS316 SUS316 Filter funnel SUS316 SUS316 SUS316 SUS316 Funnel support base SUS316 SUS316 SUS316 SUS316 Handle SUS316 SUS316 SUS316 SUS316 Connector SUS316 SUS316 SUS316 SUS316 250 S.S Manifold FILTRATION F MANF-320/620/321, Multi-Branch S.S Manifold Features: The whole set is made of SUS316 All parts of MANF-320/620 manifold are made of SUS316, MANF-320 Stainless Steel which offer excellent chemical resistance and can be fastly sterilized by flame, steam and oven etc. Light and practical aluminum design MANF-321 is made of anodized aluminum and plated copper that make it light, cost effective and autoclavable. MANF-620 Stainless Steel Individual control valve Each branch permits individual control. Compatible to different size of funnels MANF-320/620/321 manifolds use no.8 stopper which is available to fit various filter holder optionally. Applications: MANF-321 Aluminium Filtration for microbiology test Chemical experiment General liquid filtration. Ordering Information: Options: 167110-23 197000-01 MANF-320, 3 places Stainless Steel Manifold LF3, 300ml PES Filter Holder 167110-26 167110-16 MANF-620, 6 places Stainless Steel Manifold No.8 Silicon Stopper. 167200-43 MANF-321, 3 places Aluminum Manifold MANF-320 With 197100-1 & 167110-16 Model MANF-320 MANF-620 MANF-321 Number of branch 3 6 3 Filter diameter According to filter holder According to filter holder According to filter holder Funnel capacity According to filter holder According to filter holder According to filter holder Effective filtration area According to filter holder According to filter holder According to filter holder Port thread 8mm 8mm 8mm Dimension (LxWxH) mm 44.5x12.9x15 68.5x12.9x15 39.5x15x13.7 Fitting part Material Material Material Body SUS316 SUS316 Anodized aluminum Control valve SUS316 SUS316 Plated copper Handle SUS316 SUS316 Anodized aluminum Connector SUS316 SUS316 Plated copper 251 F FILTRATION Vacuum Filtration System MANF-330B/630B, Vacuum Filtration Systems 167403-11(22) Features: Special design for microbiology filtration MANF-330B/630B is designed for rapid batch filtration of microbiology test. Each system includes vacuum pump, burner, waste bottle and filter. The manifold is made of SUS316 All parts of manifold are made of SUS316 which offer MANF-330B excellent chemical resistance and can be fastly sterilized 167601-11(22) by flame, steam and oven etc. The patented spin-lock design The manifold uses a patented spin-lock connection which facilitates fast and stable installation without clamp. Applications: Filtration for microbiology test MANF-630B Chemical experiment General liguid filtration. Ordering Information 167403-11 (22) 167601-11(22) MANF-330B vacuum filtration system, complete set MANF-630B vacuum filtration system, complete set includes: includes: VP-58 Oil Free Vacuum Pump VP-34 Oil Free Vacuum Pump MANF-631, 6 Places Stainless Steel Manifold Set MANF-331, 3 Places Stainless Steel Manifold Set 3000ml PC waste bottle 3000ml PC waste bottle STER-100 Torch Burner STER-100 Torch Burner MCE Membrane, 47mm, 0.45µm, 200/PK µ MCE Membrane, 47mm, 0.45 m, 200/PK Silicon Tube (2m). Silicon Tube (2m). Model MANF-330B MANF-630B Max. flow rate 37 l/min 60 l/min Max. vacuum 670 mmHg (89.3 kPa) (120 mbar) Receiver flask 3000ml (made of PC) Number of branch 3 6 Filter diameter 47mm/50mm Funnel Capacity 100ml Effective filtration area 9.6 cm2 Port thread 8mm Fitting part Material Filter funnel SUS316 Control valve SUS316 Funnel support base SUS316 Handle SUS316 Connector SUS316 252 Microplate Vacuum Manifold FILTRATION F MVM-210, Microplate Vacuum 195210-11(22) Manifold with Vacuum Pump Features: MVM-210 One system meeting full needs Coupling with a vacuum pump, MVM-210 can be a complete set of vacuum purification system including VP-17 oil-free vacuum pump, silicone tube, waste tray, disc filter (prevent waste liquid from overflowing into pump).
Recommended publications
  • Standard Operating Procedure SEA05 Laboratory Analysis-Version
    Gulf Coast Network National Park Service Inventory and Monitoring Division Standard Operating Procedure SEA05 Laboratory Analysis—Version 1.0 Please cite this as: Meiman, J. 2019. Laboratory Analysis—Version 1.0. Gulf Coast Network Standard Operating Procedure NPS/GULN/SOP—SEA05. Gulf Coast Network, Lafayette, Louisiana. Summary This standard operating procedure (SOP) for laboratory analysis of total suspended solids (TSS) is adopted verbatim from USEPA Method 160.2. Revision Log Revision Date Author Changes Made Reason for Change New Version # METHOD #: 160.2 Approved for NPDES (Issued 1971) TITLE: Residue, Non-Filterable (Gravimetric, Dried at 103–105°C) ANALYTE: Residue, Non-Filterable INSTRUMENTATION: Drying Oven STORET No. 00530 1. Scope and Application a. This method is applicable to drinking, surface, and saline waters, domestic and industrial wastes. b. The practical range of the determination is 4 mg / L to 20,000 mg / L. 2. Summary of Method a. A well-mixed sample is filtered through a glass fiber filter, and the residue retained on the filter is dried to constant weight at 103-105°C. b. The filtrate from this method may be used for Residue, Filterable. 3. Definitions a. Residue, non-filterable, is defined as those solids which are retained by a glass fiber filter and dried to constant weight at 103-105°C. 4. Sample Handling and Preservation a. Non-representative particulates such as leaves, sticks, fish, and lumps of fecal matter should be excluded from the sample if it is determined that their inclusion is not desired in the final result. b. Preservation of the sample is not practical; analysis should begin as soon as possible.
    [Show full text]
  • SILICA, CRYSTALLINE in Coal Mine Dust, by IR 7603
    SILICA, CRYSTALLINE in coal mine dust, by IR 7603 SiO2 MW: 60.08 CAS: 14808-60-7 RTECS: VV7330000 METHOD: 7603, Issue 2 EVALUATION: UNRATED Issue 1: 15 May 1989 Issue 2: 15 August 1994 quartz (respirable): 3 OSHA : 10 mg/m /(%SiO2 + 2) PROPERTIES: solid; crystalline transformations: quartz NIOSH: 0.05 mg/m3 (suspect carcinogen) to tridymite @ 867 °C: tridymite to ACGIH: 0.1 mg/m3 crystobalite @ 1470 °C; a-quartz to b-quartz @ 573 °C SYNONYMS: free crystalline silica; silicon dioxide SAMPLING MEASUREMENT SAMPLER: CYCLONE + PREWEIGHED FILTER TECHNIQUE: INFRARED SPECTROPHOTOMETRY (IR) (10-mm cyclone, nylon, or Higgins-Dewell (HD), and PVC filter, 37-mm, 5-µm) ANALYTE: quartz FLOW RATE: HD cyclone: 2.2 L/min WEIGH: dust cassette nylon cyclone: 1.7 L/min ASH: muffle furnace or RF plasma asher VOL-MIN: 300 L @ 0.1 mg/m 3 -MAX: 1000 L REDEPOSIT: 0.45-µm acrylic copolymer membrane filter SHIPMENT: routine IR: scan, 1000 to 650 cm -1, absorbance mode SAMPLE STABILITY: stable with blank filter in reference beam BLANKS: 2 to 10 field blanks per set CALIBRATION: standard suspension of quartz in 2-propanol BULK SAMPLE: required for OSHA standard calculations; area respirable or settled dust RANGE: 30 to 250 µg quartz per sample [1] ESTIMATED LOD: 10 µg quartz per sample [1] ACCURACY PRECISION (S r): 0.098 @ 100 to 500 µg per sample RANGE STUDIED: 25 to 160 µg/sample [1] (varies with sample matrix) [1] (2 mg quartz/m 3 atmosphere) BIAS: unknown ˆ OVERALL PRECISION (S rT): 0.13 to 0.22 (varies with sample loading and matrix) ACCURACY: ±25.6 to 43.4% APPLICABILITY: The working range is 0.03 to 2 mg/m 3 for a 1000-L sample.
    [Show full text]
  • SILICA, CRYSTALLINE, by XRD (Filter Redeposition) 7500
    SILICA, CRYSTALLINE, by XRD (filter redeposition) 7500 SiO2 MW: 60.08 CAS: 14808-60-7 (quartz) RTECS: VV7330000 (quartz) 14464-46-1 (cristobalite) VV7325000 (cristobalite) 15468-32-3 (tridymite) VV7335000 (tridymite) METHOD: 7500, Issue 4 EVALUATION: FULL Issue 1: 15 August 1990 Issue 4: 15 March 2003 3 3 OSHA : quartz (respirable) 10 mg/m /(%SiO2+2); PROPERTIES: solid; d 2.65 g/cm @ 0 °C; crystalline cristobalite and tridymite (respirable) ½ the above transformations: quartz to tridymite NIOSH: 0.05 mg/m3; carcinogen @ 867 °C; tridymite to cristobalite ACGIH: quartz (respirable) 0.1 mg/m3 @ 1470 °C; "-quartz to ß-quartz cristobalite (respirable) 0.05 mg/m3 @ 573 °C tridymite (respirable) 0.05 mg/m3 SYNONYMS: free crystalline silica; silicon dioxide SAMPLING MEASUREMENT SAMPLER: CYCLONE + FILTER TECHNIQUE: X-RAY POWDER DIFFRACTION (10-mm nylon cyclone, Higgins- Dewell (HD) cyclone, or aluminum ANALYTE: Crystalline SiO2 cyclone + 5-:m PVC membrane) *see sampling section ASH: Muffle furnace or RF plasma asher or dissolve in tetrahydrofuran FLOW RATE: Nylon cyclone: 1.7 L/min; HD cyclone: 2.2 L/min; REDEPOSIT: On 0.45-:m Ag membrane filter aluminum cyclone: 2.5 L/min XRD: Cu target X-ray tube, graphite VOL-MIN: 400 L monochromator -MAX: 1000 L Optimize for intensity; 1° slit Slow step scan, 0.02°/10 sec SHIPMENT: Routine Integrated intensity with background subtraction SAMPLE STABILITY: Stable CALIBRATION: :NIST SRM 1878a quartz, NIST SRM 1879a cristobalite, USGS 210-75-0043 BLANKS: 2 to 10 per set (see step 13.g.) tridymite suspensions in 2-propanol. BULK SAMPLE: High-volume or settled dust; to RANGE: 0.02 to 2 mg SiO2 per sample [2] identify interferences ESTIMATED LOD: 0.005 mg SiO2 per sample [2] ACCURACY þ PRECISION ( r): 0.08 @ 0.05 to 0.2 mg per sample [1] RANGE STUDIED: 25 to 2500 :g/m3 [1] (800-L sample) BIAS: None known Ö : OVERALL PRECISION ( rT): 0.09 (50 to 200 g) [1] ACCURACY: ± 18% APPLICABILITY: The working range is 0.025 to 2.5 mg/m3 for an 800-L air sample.
    [Show full text]
  • Edna PROTOCOL SAMPLE COLLECTION
    eDNA PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University September 2014 Adapted from Protocol Version 04/12/2012 (D.S. Pilliod, R.S. Arkle, and M.B. Laramie) USGS Snake River Field Station MATERIALS 1. Cellulose nitrate disposable filter funnels or other field-tested, disposable filter funnels 2. Vacuum flask (1L) 3. Silicone tubing 4. Vacuum hand pump (from auto parts store) 5. Rubber stopper with hole for funnel stem 6. Latex or nitrile gloves (non-powdered) 7. Forceps (filter forceps if possible) 8. High quality, o-ring screw cap 2mL tubes (e.g., Sarstedt brand) with 1mL 100% molecular-grade ethanol (not denatured) 9. Ethanol-proof laboratory pen (do not use a regular Sharpie marker) 10. 50 mL tubes of 30 mL 1) 50% household bleach solution 2) distilled water in a holder (a foam drink holder [koozie] works well) 11. Polypropylene grab bottles and cooler (for off-site filtering) or Whirl-Pak® bags (for on- site filtering) 12. Water, bleach, scrub brush, and tubs (for decontaminating between sites) 2 3 5 1 4 2 Figure 1. Filter funnel (1), vacuum flask (2), silicone tubing (3), vacuum pump (4), and rubber stopper (5). 9 7 10 8 6 1 Figure 2. Latex or nitrile gloves (6), forceps (7), 2 mL tubes with 1 mL ethanol (8), ethanol-proof lab marker (9), and 2 50 mL tubes with 50% household bleach solution distilled water (10). 3 11a 11b Figure 3. Polypropylene grab bottles (11a) and Whirl-Pak® bag (11b). 12a 12d 12b 12c Figure 4. Water (12a), bleach (12b), scrub brushes (12c), and tubs (12d) for decontaminating boots and equipment between sites.
    [Show full text]
  • Laboratory Filtration Principles and Chemical Compatibility Chart Filtration Simplified
    Laboratory filtration Principles and chemical compatibility chart Filtration simplified Basic filtration concepts and terms Selecting a filter with the appropriate properties can help you achieve accurate results and reach discovery faster. But with so many types of filters to choose from, how can you be sure you’re making the right choice? GE Healthcare Life Sciences, maker of Whatman™ brand filtration products, has assembled this compilation of basic filtration concepts and terms to clarify the various options available to you and speed up your selection process. Ash content Hydrophilic Determined by ignition of the cellulose filter at 900°C Because hydrophilic filters possess an affinity for water in air. Minimizing ash content is essential in gravimetric and can be wetted with virtually any liquid, they are applications and also a useful measure of the level of typically used for aqueous solutions and compatible general purity. organic solvents. Chemical compatibility Hydrophobic It is very important to ensure that the structure of the These types of filters repel water, and are thus best suited filter media will not be impaired by exposure to certain for filtering organic solvents as well as for venting and chemicals. In addition, exposure to these chemicals gas filtration applications. should not cause the filter to shed fibers or particles, or add extractables. Length of exposure time, temperature, Liquid flow rate (including Herzberg method) concentration and applied pressure can all affect Under practical filtration conditions, the liquid flow rate compatibility. GE Healthcare has provided chemical will depend on a number of factors, many of which will compatibility charts to aid your filter selection.
    [Show full text]
  • Environmental DNA Sampling Protocol—Filtering Water to Capture DNA from Aquatic Organisms
    Prepared in cooperation with Washington State University Environmental DNA Sampling Protocol—Filtering Water to Capture DNA from Aquatic Organisms Chapter 13 of Section A, Biological Science Book 2, Collection of Environmental Data Techniques and Methods 2–A13 U.S. Department of the Interior U.S. Geological Survey Cover: Okanogan River, British Columbia, Canada, 2012. Insets from top to bottom: Juvenile rainbow trout from Ratz Creek, Alaska, 2009. (C)2009 ADF&G, Division of Sport Fish. Used with permission. Collecting eDNA sample from Boise River, Boise, Idaho, 2011. USGS Technician Kevin Glueckert collects eDNA sample from Boise River, Boise, Idaho, 2014. Preserving folded eDNA sample in ethanol vial-filled vial, 2012. Photographs by Matthew B. Laramie, U.S. Geological Survey, unless otherwise noted. Environmental DNA Sampling Protocol— Filtering Water to Capture DNA from Aquatic Organisms By Matthew B. Laramie, David S. Pilliod, Caren S. Goldberg, and Katherine M. Strickler Chapter 13 of Section A, Biological Science Book 2, Collection of Environmental Data Prepared in cooperation with Washington State University Techniques and Methods 2–A13 U.S. Department of the Interior U.S. Geological Survey U.S. Department of the Interior SALLY JEWELL, Secretary U.S. Geological Survey Suzette M. Kimball, Acting Director U.S. Geological Survey, Reston, Virginia: 2015 For more information on the USGS—the Federal source for science about the Earth, its natural and living resources, natural hazards, and the environment—visit http://www.usgs.gov or call 1–888–ASK–USGS. For an overview of USGS information products, including maps, imagery, and publications, visit http://www.usgs.gov/pubprod/.
    [Show full text]
  • Chemistry Lab Kit Instructions
    CHEMISTRY LAB KIT INSTRUCTIONS Not suitable for children under 10 years. For use under WARNING! adult supervision. Contains some chemicals which present a hazard to health. Read the instructions before use, follow them and keep them for reference. Do not allow chemicals to come into contact with any part of the body, particularly mouth and eyes. Keep small children and animals away from experiments. Keep the experimental set out of reach of children under 10 years old. Eye protection for supervising adults is not included. MADE IN CHINA P38-CM001-81001003 CONTENTS : 2 Test Tubes with Stoppers 1 Cleaning Brush 1 Test Tube Holder 2 Glass Tubing 1 Rubber Tubing 1 Spirit Lamp 1 Beaker(0-100ml) 1 Stirring Rod 1 Measuring Spoon 6 Filter Papers 8 Universal Indicator Paper 1 Goggles 2 Cork Stoppers with hole 1 Funnel 2 Cork Stoppers 1 Instruction Book 1 Scoop 1 Dropping Pipette 1 Test Tube Rack The Safety Rules Read these instructions before use, follow them and keep them for reference. Keep young children, animals and those not wearing eye protection away from the experimental area. Always wear eye protection. Store this experimental set out of reach of children under 10 years of age. Clean all equipment after use. Make sure that all containers are fully closed and properly stored after use. Ensure that all empty containers are disposed of properly; Wash hands after carrying out experiments. DO NOT use any equipment which has not been supplied with the set or recommended in the instructions for use. DO NOT eat or drink in the experimental area.
    [Show full text]
  • Recrystallization and Identification of an Unknown Solid
    Experiment 1: Recrystallization and Identification of an Unknown Solid I. Recrystallization Procedure: You will be given an unknown solid compound to purify by recrystallization using water as the recrystallizing solvent. The unknown will either be benzamide or 2- ethoxybenzamide and will contain a water-soluble organic impurity and a black carbon insoluble impurity. Note that the melting point ranges of benzamide and 2- ethoxybenzamide are quite close, so good technique will be required to distinguish between them. O O NH NH2 2 OCH2CH3 benzamide 2-ethoxybenzamide Pertinent information about the chemicals you are using: Reagents MW (g/mol) MP (ºC) BP (ºC) Density Benzamide 128-130 2-ethoxybenzamide 132-134 Water 18 0 100 1 Throughout this experiment, clean all glassware and equipment before using it. To clean it, wash with soap and water, rinse with water, and shake as much water as possible from it. If soap and water does not completely clean it (i.e. there is still some visible residue in it), wash with a little acetone then with water. The residue is likely organic material that the acetone will remove. This cleaning technique can be used in this experiment because water is being used as the solvent; a trace of water in the glassware will do no harm. Recrystallization of a Solid Compound: Dissolving the Solid: 1. Place a clean 250-mL Erlenmeyer flask containing approximately 100-mL water and 3- 4 boiling stones on a hot plate set to about 6; this will be used as your source of hot water when dissolving your compound for the experiment.
    [Show full text]
  • Practical Guide EDEXCEL
    Practical Guide EDEXCEL This guide includes details about the core practicals for A-level chemistry. It also contains information about other experiments that often occur in A-level examinations. You may be asked to describe these experiments in details or be asked about reasons for doing individual steps. You may be asked about other unfamiliar experiments but these will be using the skills and techniques that are described in the following experiments. Safety and hazards Irritant - dilute acid and alkalis- wear googles Hazardous substances in low Corrosive- stronger acids and alkalis wear goggles concentrations or amounts will Flammable – keep away from naked flames not pose the same risks as the Toxic – wear gloves- avoid skin contact- wash hands after use pure substance. Oxidising- Keep away from flammable / easily oxidised materials Measuring gas volumes Make sure you don’t leave gaps in Using a gas syringe your diagram where gas could Gas syringes can be used for a variety of escape experiments where the volume of a gas is measured, possibly to work out moles of gas or to follow reaction rates. Potential errors in using a gas syringe •gas escapes before bung inserted If drawing a gas syringe make sure •syringe sticks you draw it with some • some gases like carbon dioxide or sulphur dioxide are measurement markings on the soluble in water so the true amount of gas is not barrel to show measurements can measured. be made. The volume of a gas depends on pressure Alternatively gas volumes can be and temperature so when recording volume measured ‘over water’ with an up-turned it is important to note down the measuring cylinder in a trough of water temperature and pressure of the room.
    [Show full text]
  • Volumetric Flask
    Chemical Analysis Solution (Consumables) Nobel Laboratory Sdn. Bhd. Contents Beaker ............................................ pg. 01 Flask ............................................ pg. 02 Disk ............................................ pg. 05 Tube ............................................ pg. 07 Bottle ............................................ pg. 09 Funnel ............................................ pg. 11 Measure ............................................ pg. 13 Plastic Product ............................................ pg. 17 Rubber Product ............................................ pg. 27 Metalwares ............................................ pg. 31 Laboratory Accessories ............................................ pg. 34 Glassware Our glassware are made of high quality borosilicate glass, with competitive price and good quality. Beaker Low Type Beaker Description Specication Low Type Beaker 5-10000ml High Type Beaker Description Specication High Type Beaker 50-2000ml Conical Beaker Description Specication Conical Beaker 125-800ml Beaker with Handle Description Specication Beaker with Handle 100-1000ml 01 Flask Flat Bottom Flask Description Specication Flat Bottom Flask 5-20000ml Flat Bottom Flask (Ground Neck) 100-1000ml, Joint 14, 19, 24, 29, 40, 50 Round Bottom Flask Description Specication Round Bottom Flask 5-20000ml Round Bottom Flask (Ground Neck) 10-10000ml, Joint 14, 19, 24, 29, 40, 50 Kjeldahl Flask Description Specication Kjeldahl Flask 250-1000ml 02 Conical / Erlenmeyer Flask Description Specication
    [Show full text]
  • Membrane Filtration (Simultaneous Detection) for Detection Of: Total Coliforms, E
    EPA Approved* Method 10029 Coliforms: Membrane Filtration (simultaneous detection) For detection of: total coliforms, E. coli Media: m-ColiBlue24® Broth Sample Type: potable water, nonpotable water, wastewater Simultaneous Total Coliform and E. coli Screening Hach’s new m-ColiBlue24®** Broth allows for the simultaneous detection of total coliform bacteria and Escherichia coli (E. coli) within 24 hours. An enzymatic indicator in the medium causes non-fecal total coliform colonies grown on the m-ColiBlue24 medium to be red, while the E. coli (fecal coliform) colonies are blue. The selectivity of the enzymatic indicator eliminates the need for confirmation. The low false positive and false negative rates allow for the detection of at least 95% of all E. coli. m-ColiBlue24 Broth enhances the growth rate of coliform bacteria and optimizes the recovery of stressed or injured organisms. Special inhibitors in the medium efficiently minimize the growth of non-coliform bacteria. Convenient Packaging Hach’s m-ColiBlue24 Broth comes in ready-to-use PourRite™ Ampules; no need to measure, mix, or autoclave. The ampules have a large, unrestrictive opening that allows the medium to pour easily. Simply break the top off the ampule, using the Hach ampule breaker, and pour the medium onto an absorbent pad in a petri dish. Each ampule contains enough selective medium for one test. Medium in PourRite ampules has a shelf life of one year. Ampules are shipped with a Certificate of Analysis and have an expiration date printed on the label. m-ColiBlue24 Broth is also available in plastic ampules and 100 mL bottles. Specifications Incubation: 24 hours at 35 ± 0.5 °C Sensitivity: 1 CFU/100 mL Selectivity: Detects total coliforms and E.
    [Show full text]
  • Experiment 5
    Experiment Aspirin Synthesis 5 Aspirin is the common name for the compound acetylsalicylic acid, widely used as a fever reducer and as a pain killer. Salicylic acid, whose name comes from Salix, the willow family of plants, was derived from willow bark extracts. In folk medicine, willow bark teas were used as headache remedies and other tonics. Nowadays, salicylic acid is administered in the form of aspirin which is less irritating to the stomach than salicylic acid. To prepare aspirin, salicylic acid is reacted with an excess of acetic anhydride. A small amount of a strong acid is used as a catalyst which speeds up the reaction. In this experiment, phosphoric acid will be used as the catalyst. The excess acetic acid will be quenched with the addition of water. The aspirin product is not very soluble in water so the aspirin product will precipitate when water is added. The synthesis reaction of aspirin is shown below: H3PO4 102 g/ mol 138 g/mol d = 1.08 g/mL 180 g/mol Since acetic acid is very soluble in water, it is easily separated from the aspirin product. The aspirin isolated in this step is the “crude product”. A “purified product” can be obtained through recrystallization of the crude product in hot ethanol. In this experiment, the crude product will be the desired product. The percent yield of the crude product will be determined for this reaction. The purity of the product will also be analyzed. The product will be analyzed by three different methods: melting point, titration, and spectroscopic assay.
    [Show full text]