Microbiology Quality Control Introduction

Total Page:16

File Type:pdf, Size:1020Kb

Microbiology Quality Control Introduction Microbiology Quality Control introduction When left undetected, micro- Content organisms can halt the production 208 Pharmaceutical Quality Control of pharmaceuticals, spoil food, ruin the Application Selector taste of beverages, negatively impact the performance of 209 Beverage Quality Control Application Selector computer chips, and cause serious illness. That’s why Pall is MICROBIOLOGY QUALITY CONTROL 210 Microbiology Quality dedicated to finding new and better ways to help you accurately Control Overview and reliably identify these microorganisms to protect both public 212 Microbiology Quality Control – Online Reference Library safety and the integrity of industrial assets. 213 Microbiology Quality Control Pall has been setting performance standards in Microbiology 213 Products – Membranes Quality Control laboratories for more than 50 years, and our 216 Products – Media products are referenced and recommended by regulatory 218 Products – Filter Funnels agencies worldwide. We invite you to explore the many ways 228 Products – Hardware Pall’s sample prep solutions can enhance your pharmaceutical 230 Products – Accessories and beverage quality control applications. 1. 8 0 0 .5 2 1 . 1 5 2 0 ( U S A and Canada) (+)800.PALL.LIFE (Outside USA and Canada) www.pall.com/lab 207 Pharmaceutical Quality Control Application Selector Membranes Page Number PseudomonasDetection sp. Total BacteriaDetection Total ColiformsDetection Fecal ColiformsDetection Yeast Detectionand Mold GN-6 Metricel® MCE membrane disc filters, S-pack 213 • • • • • Metricel Black PES membrane disc filters, S-pack 214 • • Sentino™ Filter Dispenser 213a • • • • • Supor® 200 PES membrane disc filters, S-pack 215 • • Ampoule Media* HPC with TTC indicator broth 216 • M-FC broth 216 • MF-Endo broth 216 • M-Green YM broth 216 • M-TGE broth 216 • Pseudomonas broth 216 • Trypticase Soy broth - USP 216 • Filter Funnels 47 mm magnetic filter funnels 226 • • • • • MicroFunnel™ filter funnels, 100 and 300 mL 218 • • • • • MicroFunnel Plus filter funnels, 100 and 300 mL 220 • • • • • MicroFunnel ST filter funnels, 100 and 300 mL 222 • • • • • Sentino Magnetic filter funnels 225a • • • • • Vents Vacushield™ vent device 165 • • • • • application selector Hardware and Accessories Absorbent pad kits 231 • • • • • Filter funnel manifolds 229 • • • • • Filter funnel manifolds for MicroFunnel filter funnels 228 • • • • • Petri dishes 230, 280 • • • • • Sentino Microbiology Pump 224 • • • • • Stainless steel forceps 230, 280 • • • • • Vacuum/pressure pumps 279 • • • • • * Culture media listed may or may not meet the requirements of a regulated test method. It is the responsibility of the user to determine applicability in each situation. MICROBIOLOGY QUALITY CONTROL 208 Beverage Quality Control Application Selector Membranes Page Number LactobacillusDetection sp. Total BacteriaDetection Total ColiformsDetection Fecal ColiformsDetection Yeast Detectionand Mold GN-6 Metricel® MCE membrane disc filters, S-pack 213 • • • • • Metricel Black PES membrane disc filters, S-pack 214 • • • • Sentino™ Filter Dispenser 213a • • • • • Supor® 200 PES membrane disc filters, S-pack 215 • • Ampoule Media* HPC with TTC indicator broth 216 • M-FC broth 216 • MF-Endo broth 216 • M-Green YM broth 216 • M-TGE broth 216 • Orange Serum broth 216 • Trypticase Soy broth - USP 216 • application selector Filter Funnels 47 mm magnetic filter funnels 226 • • • • • Microcheck® II beverage monitors 227 • • • • • Sentino Magnetic filter funnels 225a • • • • • Vents Vacushield™ vent device 165 • • • • • Hardware and Accessories Filter funnel manifolds 229 • • • • • Filter funnel manifolds for MicroFunnel™ filter funnels 228 • • • • • Petri dishes 230, 280 • • • • • Sentino Microbiology Pump 224 • • • • • MICROBIOLOGY QUALITY CONTROL Stainless steel forceps 230, 280 • • • • • Vacuum/pressure pumps 279 • • • • • * Culture media listed may or may not meet the requirements of a regulated test method. It is the responsibility of the user to determine applicability in each situation. 1. 8 0 0 .5 2 1 . 1 5 2 0 ( U S A and Canada) (+)800.PALL.LIFE (Outside USA and Canada) www.pall.com/lab 209 Microbiology Quality Control Rapid, Reliable Results The accurate, reliable detection and identification of micro- organisms is critical to public safety and industrial economics. As we become more aware of the presence and variety of the organisms that share the world we live in, we realize the importance of knowing how to detect and control them. Pall is a leader in the development and manufacture of products to detect and control these microorganisms. Our products comply with international testing methods, are supported by technical literature, and carry certifications of quality. You can be confident that our affordable, easy-to-use products will meet the high quality standards you require. Membranes Culturing sensitive organisms can be difficult, and identification is critical for process control and public safety. Analysis membranes must be manufactured to the highest standards for accurate microbial growth and recovery. Pall’s mixed cellulose ester GN Metricel® membrane has set the standard worldwide for meeting stringent microbial regulations. Supor® Rely on Pall Life Sciences to simplify your microbiological analysis with our popular line of disposable MicroFunnel and Metricel Black membranes provide additional benefits filter funnels, quality hardware, and convenient accessories. that range from low drug and protein binding characteristics to background contrast for ease in counting colonies. Thoughtfully Designed Hardware These membranes provide uniform and consistent growth and Accessories of organisms. Pall offers a full line of microbiological ampoule media, MicroFunnel™ Disposable Filter Funnels laboratory hardware, and accessories like our Sentino™ Pall offers the widest selection of disposable filter funnels for Microbiology Pump, Sentino Filter Dispenser, Petri dishes, microbiological analysis, offering unique design features that and stainless steel forceps to simplify your microbial analysis give these products a reputation for quality and ease of use. procedures. application overview Industrial Microbiology Products MicroFunnel filter funnels make analysis easy. Design permits a simple squeeze separation of funnel from base to Ensuring the effectiveness of cleaning procedures, quality of access membrane. raw materials, and reliable processing capabilities are essential Funnels attach directly to standard laboratory manifolds, to preparing a safe, high quality end product. Pall’s 37 mm and volume graduations are clearly marked to make it easy Quality Monitor is used to monitor microelectronics water to measure your sample volume. quality to detect microorganism contamination that can block a sub-micron circuit path on a computer chip. The food and Each unit is individually bagged, gamma-irradiated, and beverage industry chooses the easy-to-use Microcheck™ II labeled for added assurance of lot traceability. beverage monitors to improve speed, productivity, and accuracy in the lab. MICROBIOLOGY QUALITY CONTROL 210 Responding to Contamination Control With Disposable Funnels The pharmaceutical microbiology market requires reliable and MicroFunnel Filter Funnels Demonstrate High accurate results as a basis for quality control of raw materials, Recovery of Test Organisms processes, and finished product. Critical decisions are made Test organism: daily and confidence in results, as well as methods to control Escherichia coli ATCC 11229 contamination during sampling and analysis, is a driving force % recovery % recovery in this market. A false positive on a test result can trigger a incubated in incubated by PN 4800 (GN-6 Metricel® base using removing to series of events that lead to unnecessary retesting, product membrane, 0.45 µm, TSB broth, MF-Endo broth, release delays, and extensive paperwork to document a white, gridded) 5 test units 5 test units course of action. This all leads to increased operating costs. Lot 1048L 98% 96% One way Pall Life Sciences has responded to contamination Lot 1382L 98% 94% control is by broadening our range of disposable filter funnels Lot 1878L 94% 98% with designs to help improve the sampling process. Whether the need is bioburden analysis, sterility testing, or water Test organism: Pseudomonas system monitoring, we have a MicroFunnel™ filter funnel aeruginosa ATCC 14207 to suit the application. Certified MicroFunnel disposable % recovery % recovery filter funnels are individually bagged, labeled, and ready incubated in incubated by to use. Each lot is evaluated for recovery performance. PN 4803 (Supor® base using removing to The standard selection of MicroFunnel filter funnels is ideal membrane, 0.2 µm, TSB broth, Pseudomonas white, gridded) 5 test units broth, 5 test units for any bioburden analysis. Lot 1305L 97% 91% application overview Lot 1443L 97% 97% Lot 1179M 96% 101% Test organism: Saccharomyces cerevisiae ATCC 4117 % recovery % recovery incubated in incubated by base using removing to PN 4805 (Metricel Black M-Green M-Green membrane, 0.45 µm, YM broth, YM broth, gridded) 5 test units 5 test units Lot 1197M 96% 101% Lot 1626M 100% 97% Lot 1933M 100% 103% MICROBIOLOGY QUALITY CONTROL MicroFunnel Plus filter funnels streamline QC testing. Simple, Versatile Contamination Control MicroFunnel Plus filter funnels are the only disposable filter funnels on the market that can serve as a sample cup and filter funnel in one product. This unique design further stream- lines sample collection
Recommended publications
  • Standard Operating Procedure SEA05 Laboratory Analysis-Version
    Gulf Coast Network National Park Service Inventory and Monitoring Division Standard Operating Procedure SEA05 Laboratory Analysis—Version 1.0 Please cite this as: Meiman, J. 2019. Laboratory Analysis—Version 1.0. Gulf Coast Network Standard Operating Procedure NPS/GULN/SOP—SEA05. Gulf Coast Network, Lafayette, Louisiana. Summary This standard operating procedure (SOP) for laboratory analysis of total suspended solids (TSS) is adopted verbatim from USEPA Method 160.2. Revision Log Revision Date Author Changes Made Reason for Change New Version # METHOD #: 160.2 Approved for NPDES (Issued 1971) TITLE: Residue, Non-Filterable (Gravimetric, Dried at 103–105°C) ANALYTE: Residue, Non-Filterable INSTRUMENTATION: Drying Oven STORET No. 00530 1. Scope and Application a. This method is applicable to drinking, surface, and saline waters, domestic and industrial wastes. b. The practical range of the determination is 4 mg / L to 20,000 mg / L. 2. Summary of Method a. A well-mixed sample is filtered through a glass fiber filter, and the residue retained on the filter is dried to constant weight at 103-105°C. b. The filtrate from this method may be used for Residue, Filterable. 3. Definitions a. Residue, non-filterable, is defined as those solids which are retained by a glass fiber filter and dried to constant weight at 103-105°C. 4. Sample Handling and Preservation a. Non-representative particulates such as leaves, sticks, fish, and lumps of fecal matter should be excluded from the sample if it is determined that their inclusion is not desired in the final result. b. Preservation of the sample is not practical; analysis should begin as soon as possible.
    [Show full text]
  • SILICA, CRYSTALLINE in Coal Mine Dust, by IR 7603
    SILICA, CRYSTALLINE in coal mine dust, by IR 7603 SiO2 MW: 60.08 CAS: 14808-60-7 RTECS: VV7330000 METHOD: 7603, Issue 2 EVALUATION: UNRATED Issue 1: 15 May 1989 Issue 2: 15 August 1994 quartz (respirable): 3 OSHA : 10 mg/m /(%SiO2 + 2) PROPERTIES: solid; crystalline transformations: quartz NIOSH: 0.05 mg/m3 (suspect carcinogen) to tridymite @ 867 °C: tridymite to ACGIH: 0.1 mg/m3 crystobalite @ 1470 °C; a-quartz to b-quartz @ 573 °C SYNONYMS: free crystalline silica; silicon dioxide SAMPLING MEASUREMENT SAMPLER: CYCLONE + PREWEIGHED FILTER TECHNIQUE: INFRARED SPECTROPHOTOMETRY (IR) (10-mm cyclone, nylon, or Higgins-Dewell (HD), and PVC filter, 37-mm, 5-µm) ANALYTE: quartz FLOW RATE: HD cyclone: 2.2 L/min WEIGH: dust cassette nylon cyclone: 1.7 L/min ASH: muffle furnace or RF plasma asher VOL-MIN: 300 L @ 0.1 mg/m 3 -MAX: 1000 L REDEPOSIT: 0.45-µm acrylic copolymer membrane filter SHIPMENT: routine IR: scan, 1000 to 650 cm -1, absorbance mode SAMPLE STABILITY: stable with blank filter in reference beam BLANKS: 2 to 10 field blanks per set CALIBRATION: standard suspension of quartz in 2-propanol BULK SAMPLE: required for OSHA standard calculations; area respirable or settled dust RANGE: 30 to 250 µg quartz per sample [1] ESTIMATED LOD: 10 µg quartz per sample [1] ACCURACY PRECISION (S r): 0.098 @ 100 to 500 µg per sample RANGE STUDIED: 25 to 160 µg/sample [1] (varies with sample matrix) [1] (2 mg quartz/m 3 atmosphere) BIAS: unknown ˆ OVERALL PRECISION (S rT): 0.13 to 0.22 (varies with sample loading and matrix) ACCURACY: ±25.6 to 43.4% APPLICABILITY: The working range is 0.03 to 2 mg/m 3 for a 1000-L sample.
    [Show full text]
  • SILICA, CRYSTALLINE, by XRD (Filter Redeposition) 7500
    SILICA, CRYSTALLINE, by XRD (filter redeposition) 7500 SiO2 MW: 60.08 CAS: 14808-60-7 (quartz) RTECS: VV7330000 (quartz) 14464-46-1 (cristobalite) VV7325000 (cristobalite) 15468-32-3 (tridymite) VV7335000 (tridymite) METHOD: 7500, Issue 4 EVALUATION: FULL Issue 1: 15 August 1990 Issue 4: 15 March 2003 3 3 OSHA : quartz (respirable) 10 mg/m /(%SiO2+2); PROPERTIES: solid; d 2.65 g/cm @ 0 °C; crystalline cristobalite and tridymite (respirable) ½ the above transformations: quartz to tridymite NIOSH: 0.05 mg/m3; carcinogen @ 867 °C; tridymite to cristobalite ACGIH: quartz (respirable) 0.1 mg/m3 @ 1470 °C; "-quartz to ß-quartz cristobalite (respirable) 0.05 mg/m3 @ 573 °C tridymite (respirable) 0.05 mg/m3 SYNONYMS: free crystalline silica; silicon dioxide SAMPLING MEASUREMENT SAMPLER: CYCLONE + FILTER TECHNIQUE: X-RAY POWDER DIFFRACTION (10-mm nylon cyclone, Higgins- Dewell (HD) cyclone, or aluminum ANALYTE: Crystalline SiO2 cyclone + 5-:m PVC membrane) *see sampling section ASH: Muffle furnace or RF plasma asher or dissolve in tetrahydrofuran FLOW RATE: Nylon cyclone: 1.7 L/min; HD cyclone: 2.2 L/min; REDEPOSIT: On 0.45-:m Ag membrane filter aluminum cyclone: 2.5 L/min XRD: Cu target X-ray tube, graphite VOL-MIN: 400 L monochromator -MAX: 1000 L Optimize for intensity; 1° slit Slow step scan, 0.02°/10 sec SHIPMENT: Routine Integrated intensity with background subtraction SAMPLE STABILITY: Stable CALIBRATION: :NIST SRM 1878a quartz, NIST SRM 1879a cristobalite, USGS 210-75-0043 BLANKS: 2 to 10 per set (see step 13.g.) tridymite suspensions in 2-propanol. BULK SAMPLE: High-volume or settled dust; to RANGE: 0.02 to 2 mg SiO2 per sample [2] identify interferences ESTIMATED LOD: 0.005 mg SiO2 per sample [2] ACCURACY þ PRECISION ( r): 0.08 @ 0.05 to 0.2 mg per sample [1] RANGE STUDIED: 25 to 2500 :g/m3 [1] (800-L sample) BIAS: None known Ö : OVERALL PRECISION ( rT): 0.09 (50 to 200 g) [1] ACCURACY: ± 18% APPLICABILITY: The working range is 0.025 to 2.5 mg/m3 for an 800-L air sample.
    [Show full text]
  • Edna PROTOCOL SAMPLE COLLECTION
    eDNA PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University September 2014 Adapted from Protocol Version 04/12/2012 (D.S. Pilliod, R.S. Arkle, and M.B. Laramie) USGS Snake River Field Station MATERIALS 1. Cellulose nitrate disposable filter funnels or other field-tested, disposable filter funnels 2. Vacuum flask (1L) 3. Silicone tubing 4. Vacuum hand pump (from auto parts store) 5. Rubber stopper with hole for funnel stem 6. Latex or nitrile gloves (non-powdered) 7. Forceps (filter forceps if possible) 8. High quality, o-ring screw cap 2mL tubes (e.g., Sarstedt brand) with 1mL 100% molecular-grade ethanol (not denatured) 9. Ethanol-proof laboratory pen (do not use a regular Sharpie marker) 10. 50 mL tubes of 30 mL 1) 50% household bleach solution 2) distilled water in a holder (a foam drink holder [koozie] works well) 11. Polypropylene grab bottles and cooler (for off-site filtering) or Whirl-Pak® bags (for on- site filtering) 12. Water, bleach, scrub brush, and tubs (for decontaminating between sites) 2 3 5 1 4 2 Figure 1. Filter funnel (1), vacuum flask (2), silicone tubing (3), vacuum pump (4), and rubber stopper (5). 9 7 10 8 6 1 Figure 2. Latex or nitrile gloves (6), forceps (7), 2 mL tubes with 1 mL ethanol (8), ethanol-proof lab marker (9), and 2 50 mL tubes with 50% household bleach solution distilled water (10). 3 11a 11b Figure 3. Polypropylene grab bottles (11a) and Whirl-Pak® bag (11b). 12a 12d 12b 12c Figure 4. Water (12a), bleach (12b), scrub brushes (12c), and tubs (12d) for decontaminating boots and equipment between sites.
    [Show full text]
  • Laboratory Filtration Principles and Chemical Compatibility Chart Filtration Simplified
    Laboratory filtration Principles and chemical compatibility chart Filtration simplified Basic filtration concepts and terms Selecting a filter with the appropriate properties can help you achieve accurate results and reach discovery faster. But with so many types of filters to choose from, how can you be sure you’re making the right choice? GE Healthcare Life Sciences, maker of Whatman™ brand filtration products, has assembled this compilation of basic filtration concepts and terms to clarify the various options available to you and speed up your selection process. Ash content Hydrophilic Determined by ignition of the cellulose filter at 900°C Because hydrophilic filters possess an affinity for water in air. Minimizing ash content is essential in gravimetric and can be wetted with virtually any liquid, they are applications and also a useful measure of the level of typically used for aqueous solutions and compatible general purity. organic solvents. Chemical compatibility Hydrophobic It is very important to ensure that the structure of the These types of filters repel water, and are thus best suited filter media will not be impaired by exposure to certain for filtering organic solvents as well as for venting and chemicals. In addition, exposure to these chemicals gas filtration applications. should not cause the filter to shed fibers or particles, or add extractables. Length of exposure time, temperature, Liquid flow rate (including Herzberg method) concentration and applied pressure can all affect Under practical filtration conditions, the liquid flow rate compatibility. GE Healthcare has provided chemical will depend on a number of factors, many of which will compatibility charts to aid your filter selection.
    [Show full text]
  • Environmental DNA Sampling Protocol—Filtering Water to Capture DNA from Aquatic Organisms
    Prepared in cooperation with Washington State University Environmental DNA Sampling Protocol—Filtering Water to Capture DNA from Aquatic Organisms Chapter 13 of Section A, Biological Science Book 2, Collection of Environmental Data Techniques and Methods 2–A13 U.S. Department of the Interior U.S. Geological Survey Cover: Okanogan River, British Columbia, Canada, 2012. Insets from top to bottom: Juvenile rainbow trout from Ratz Creek, Alaska, 2009. (C)2009 ADF&G, Division of Sport Fish. Used with permission. Collecting eDNA sample from Boise River, Boise, Idaho, 2011. USGS Technician Kevin Glueckert collects eDNA sample from Boise River, Boise, Idaho, 2014. Preserving folded eDNA sample in ethanol vial-filled vial, 2012. Photographs by Matthew B. Laramie, U.S. Geological Survey, unless otherwise noted. Environmental DNA Sampling Protocol— Filtering Water to Capture DNA from Aquatic Organisms By Matthew B. Laramie, David S. Pilliod, Caren S. Goldberg, and Katherine M. Strickler Chapter 13 of Section A, Biological Science Book 2, Collection of Environmental Data Prepared in cooperation with Washington State University Techniques and Methods 2–A13 U.S. Department of the Interior U.S. Geological Survey U.S. Department of the Interior SALLY JEWELL, Secretary U.S. Geological Survey Suzette M. Kimball, Acting Director U.S. Geological Survey, Reston, Virginia: 2015 For more information on the USGS—the Federal source for science about the Earth, its natural and living resources, natural hazards, and the environment—visit http://www.usgs.gov or call 1–888–ASK–USGS. For an overview of USGS information products, including maps, imagery, and publications, visit http://www.usgs.gov/pubprod/.
    [Show full text]
  • Chemistry Lab Kit Instructions
    CHEMISTRY LAB KIT INSTRUCTIONS Not suitable for children under 10 years. For use under WARNING! adult supervision. Contains some chemicals which present a hazard to health. Read the instructions before use, follow them and keep them for reference. Do not allow chemicals to come into contact with any part of the body, particularly mouth and eyes. Keep small children and animals away from experiments. Keep the experimental set out of reach of children under 10 years old. Eye protection for supervising adults is not included. MADE IN CHINA P38-CM001-81001003 CONTENTS : 2 Test Tubes with Stoppers 1 Cleaning Brush 1 Test Tube Holder 2 Glass Tubing 1 Rubber Tubing 1 Spirit Lamp 1 Beaker(0-100ml) 1 Stirring Rod 1 Measuring Spoon 6 Filter Papers 8 Universal Indicator Paper 1 Goggles 2 Cork Stoppers with hole 1 Funnel 2 Cork Stoppers 1 Instruction Book 1 Scoop 1 Dropping Pipette 1 Test Tube Rack The Safety Rules Read these instructions before use, follow them and keep them for reference. Keep young children, animals and those not wearing eye protection away from the experimental area. Always wear eye protection. Store this experimental set out of reach of children under 10 years of age. Clean all equipment after use. Make sure that all containers are fully closed and properly stored after use. Ensure that all empty containers are disposed of properly; Wash hands after carrying out experiments. DO NOT use any equipment which has not been supplied with the set or recommended in the instructions for use. DO NOT eat or drink in the experimental area.
    [Show full text]
  • Recrystallization and Identification of an Unknown Solid
    Experiment 1: Recrystallization and Identification of an Unknown Solid I. Recrystallization Procedure: You will be given an unknown solid compound to purify by recrystallization using water as the recrystallizing solvent. The unknown will either be benzamide or 2- ethoxybenzamide and will contain a water-soluble organic impurity and a black carbon insoluble impurity. Note that the melting point ranges of benzamide and 2- ethoxybenzamide are quite close, so good technique will be required to distinguish between them. O O NH NH2 2 OCH2CH3 benzamide 2-ethoxybenzamide Pertinent information about the chemicals you are using: Reagents MW (g/mol) MP (ºC) BP (ºC) Density Benzamide 128-130 2-ethoxybenzamide 132-134 Water 18 0 100 1 Throughout this experiment, clean all glassware and equipment before using it. To clean it, wash with soap and water, rinse with water, and shake as much water as possible from it. If soap and water does not completely clean it (i.e. there is still some visible residue in it), wash with a little acetone then with water. The residue is likely organic material that the acetone will remove. This cleaning technique can be used in this experiment because water is being used as the solvent; a trace of water in the glassware will do no harm. Recrystallization of a Solid Compound: Dissolving the Solid: 1. Place a clean 250-mL Erlenmeyer flask containing approximately 100-mL water and 3- 4 boiling stones on a hot plate set to about 6; this will be used as your source of hot water when dissolving your compound for the experiment.
    [Show full text]
  • Practical Guide EDEXCEL
    Practical Guide EDEXCEL This guide includes details about the core practicals for A-level chemistry. It also contains information about other experiments that often occur in A-level examinations. You may be asked to describe these experiments in details or be asked about reasons for doing individual steps. You may be asked about other unfamiliar experiments but these will be using the skills and techniques that are described in the following experiments. Safety and hazards Irritant - dilute acid and alkalis- wear googles Hazardous substances in low Corrosive- stronger acids and alkalis wear goggles concentrations or amounts will Flammable – keep away from naked flames not pose the same risks as the Toxic – wear gloves- avoid skin contact- wash hands after use pure substance. Oxidising- Keep away from flammable / easily oxidised materials Measuring gas volumes Make sure you don’t leave gaps in Using a gas syringe your diagram where gas could Gas syringes can be used for a variety of escape experiments where the volume of a gas is measured, possibly to work out moles of gas or to follow reaction rates. Potential errors in using a gas syringe •gas escapes before bung inserted If drawing a gas syringe make sure •syringe sticks you draw it with some • some gases like carbon dioxide or sulphur dioxide are measurement markings on the soluble in water so the true amount of gas is not barrel to show measurements can measured. be made. The volume of a gas depends on pressure Alternatively gas volumes can be and temperature so when recording volume measured ‘over water’ with an up-turned it is important to note down the measuring cylinder in a trough of water temperature and pressure of the room.
    [Show full text]
  • Volumetric Flask
    Chemical Analysis Solution (Consumables) Nobel Laboratory Sdn. Bhd. Contents Beaker ............................................ pg. 01 Flask ............................................ pg. 02 Disk ............................................ pg. 05 Tube ............................................ pg. 07 Bottle ............................................ pg. 09 Funnel ............................................ pg. 11 Measure ............................................ pg. 13 Plastic Product ............................................ pg. 17 Rubber Product ............................................ pg. 27 Metalwares ............................................ pg. 31 Laboratory Accessories ............................................ pg. 34 Glassware Our glassware are made of high quality borosilicate glass, with competitive price and good quality. Beaker Low Type Beaker Description Specication Low Type Beaker 5-10000ml High Type Beaker Description Specication High Type Beaker 50-2000ml Conical Beaker Description Specication Conical Beaker 125-800ml Beaker with Handle Description Specication Beaker with Handle 100-1000ml 01 Flask Flat Bottom Flask Description Specication Flat Bottom Flask 5-20000ml Flat Bottom Flask (Ground Neck) 100-1000ml, Joint 14, 19, 24, 29, 40, 50 Round Bottom Flask Description Specication Round Bottom Flask 5-20000ml Round Bottom Flask (Ground Neck) 10-10000ml, Joint 14, 19, 24, 29, 40, 50 Kjeldahl Flask Description Specication Kjeldahl Flask 250-1000ml 02 Conical / Erlenmeyer Flask Description Specication
    [Show full text]
  • Membrane Filtration (Simultaneous Detection) for Detection Of: Total Coliforms, E
    EPA Approved* Method 10029 Coliforms: Membrane Filtration (simultaneous detection) For detection of: total coliforms, E. coli Media: m-ColiBlue24® Broth Sample Type: potable water, nonpotable water, wastewater Simultaneous Total Coliform and E. coli Screening Hach’s new m-ColiBlue24®** Broth allows for the simultaneous detection of total coliform bacteria and Escherichia coli (E. coli) within 24 hours. An enzymatic indicator in the medium causes non-fecal total coliform colonies grown on the m-ColiBlue24 medium to be red, while the E. coli (fecal coliform) colonies are blue. The selectivity of the enzymatic indicator eliminates the need for confirmation. The low false positive and false negative rates allow for the detection of at least 95% of all E. coli. m-ColiBlue24 Broth enhances the growth rate of coliform bacteria and optimizes the recovery of stressed or injured organisms. Special inhibitors in the medium efficiently minimize the growth of non-coliform bacteria. Convenient Packaging Hach’s m-ColiBlue24 Broth comes in ready-to-use PourRite™ Ampules; no need to measure, mix, or autoclave. The ampules have a large, unrestrictive opening that allows the medium to pour easily. Simply break the top off the ampule, using the Hach ampule breaker, and pour the medium onto an absorbent pad in a petri dish. Each ampule contains enough selective medium for one test. Medium in PourRite ampules has a shelf life of one year. Ampules are shipped with a Certificate of Analysis and have an expiration date printed on the label. m-ColiBlue24 Broth is also available in plastic ampules and 100 mL bottles. Specifications Incubation: 24 hours at 35 ± 0.5 °C Sensitivity: 1 CFU/100 mL Selectivity: Detects total coliforms and E.
    [Show full text]
  • Experiment 5
    Experiment Aspirin Synthesis 5 Aspirin is the common name for the compound acetylsalicylic acid, widely used as a fever reducer and as a pain killer. Salicylic acid, whose name comes from Salix, the willow family of plants, was derived from willow bark extracts. In folk medicine, willow bark teas were used as headache remedies and other tonics. Nowadays, salicylic acid is administered in the form of aspirin which is less irritating to the stomach than salicylic acid. To prepare aspirin, salicylic acid is reacted with an excess of acetic anhydride. A small amount of a strong acid is used as a catalyst which speeds up the reaction. In this experiment, phosphoric acid will be used as the catalyst. The excess acetic acid will be quenched with the addition of water. The aspirin product is not very soluble in water so the aspirin product will precipitate when water is added. The synthesis reaction of aspirin is shown below: H3PO4 102 g/ mol 138 g/mol d = 1.08 g/mL 180 g/mol Since acetic acid is very soluble in water, it is easily separated from the aspirin product. The aspirin isolated in this step is the “crude product”. A “purified product” can be obtained through recrystallization of the crude product in hot ethanol. In this experiment, the crude product will be the desired product. The percent yield of the crude product will be determined for this reaction. The purity of the product will also be analyzed. The product will be analyzed by three different methods: melting point, titration, and spectroscopic assay.
    [Show full text]