Section 02660

Total Page:16

File Type:pdf, Size:1020Kb

Section 02660 SECTION 00901 ADDENDUM NO. 1 Date Issued December 10, 2019 Town of Mead JVA, Incorporated WWTF Fire Alarm and Sludge Flow Meter 213 Linden Street Improvements Suite 200 441 3rd Street Fort Collins, CO 80524 Mead, CO 80542 (970) 225-9099 PART 1 GENERAL 1.1 DESCRIPTION A. This addendum forms a part of the Bidding and Contract Documents and modifies the Drawings as described below B. This addendum consists of this page and five drawings 1.2 ACKNOWLEDGMENT A. Acknowledge receipt of this addendum in the space provided on the Bidder’s Certification form. PART 2 DRAWINGS 2.1 REPLACE ALL THE DRAWINGS WITH THE ATTACHED DRAWINGS DATED DECEMBER 2019 A. Details for Drawing P1.0 were added to show installation for the effluent flow meter and pipe support for sludge loadout station B. Detail for Drawing E1.0 was added to show removal of a section of sidewalk to trench conduit for the digested sludge flow meter C. All other Drawings are the same 12/10/19 00901-1 JVA 1970.1c TOWN OF MEAD Set No._______ WASTEWATER TREATMENT FACILITY FIRE ALARM AND SLUDGE FLOW METER IMPROVEMENTS JVA, Inc. 1319 Spruce Street Boulder, CO 80302 303.444.1951 www.jvajva.com Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver DECEMBER 2019 JVA, Inc. 1319 Spruce Street Boulder, CO 80302 303.444.1951 www.jvajva.com Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver REVISION DESCRIPTION AND SLUDGE LOADING STATION SUPPORT – ADDITION OF EFFLUENT FLOW METER REPLACEMENT – – – – – JCD D'WN JPM DES'D DATE 12/06/19 1 NO. DESIGNED BY: JPM DRAWN BY: JCD CHECKED BY: KAT JOB #: 1970.1c DATE: DEC 2019 © JVA, INC. TOWN OF MEAD WWTP FIRE ALARM AND DIGESTER PLAN AND SECTIONS SLUDGE FLOW METER IMPROVEMENTS SHEET NO. P1.0 JVA, Inc. 1319 Spruce Street Boulder, CO 80302 303.444.1951 www.jvajva.com ONE LINE DIAGRAM LEGEND SCHEMATIC SYMBOLS ABBREVIATIONS AREA DESIGNATIONS Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver VACUUM SWITCH (CLOSING ON THE SPECIAL AREA DESIGNATION BOXES, AS DEFINED BELOW, ARE LOCATED ON THE PLAN WIRE CONNECTION POINT INCREASING VACUUM) A AMBER, AMPERE, ALARM RECP RECEPTACLE TRANSFORMER WITH PRIMARY AND SECONDARY AC ALTERNATING CURRENT RGS RIGID GALVANIZED STEEL DRAWINGS TO DEFINE ELECTRICAL INSTALLATION REQUIREMENTS. DESIGNATION BOXES ARE LOCATED WITHIN ROOM OR BELOW ROOM NUMBER. ALL INDOOR AREAS NOT INDICATED VOLTAGE, AND KVA RATING AS NOTED. NORMALLY OPEN CONTACT VACUUM SWITCH (OPENING ON AFD ADJUSTABLE FREQUENCY RTD RESISTANCE TYPE TEMP OTHERWISE ARE AREA TYPE 1 AND MINIMUM NEMA TYPE 1 ENCLOSURES. 1500KVA INCREASING VACUUM) DRIVE DETECTOR 2.4KV-480Y/277 NORMALLY CLOSED CONTACT AFF ABOVE FINISHED FLOOR RTU REMOTE TERMINAL UNIT TEMPERATURE SWITCH (CLOSING ON 3Ø, 60 HZ AM AMMETER RVSS REDUCED VOLTAGE SOLID AREA TYPE 1A CORROSIVE CHEMICAL FEED AND STORAGE ROOMS. CONDUIT SYSTEM SHALL BE RISING TEMPERATURE) EXPOSED PVC RIGID NON-METALLIC CONDUIT WITH PVC FITTINGS, BOXES, AND STARTER, CONTACTOR OR RELAY ATO AUTOMATIC THROWOVER STATE STARTER 22: 3#8,#10G,2" CIRCUIT NO. 22 WITH #8 INSULATED CONDUCTORS, 1#10 ACCESSORIES. COIL AWG AMERICAN WIRE GAUGE S2 SIZE 2 STARTER BARE GROUND WIRE ALL IN 2" CONDUIT TO 20 HP MOTOR. TEMPERATURE SWITCH (OPENING ON RISING TEMPERATURE) C CLOSE, COUNTER, SCADA SUPERVISORY CONTROL AND LITTLETON, CO 80127 INDOOR WET LOCATIONS SUCH AS VAULTS, HOSEDOWN AREAS, BASEMENTS, ETC. (720) 344-7771 NORMALLY OPEN PUSH BUTTON CONTACTOR DATA ACQUISITION AREA TYPE 4 ONE-LINE SHOWING POWER AND CONTROL TO A PACKAGE FLOW ACTUATED SWITCH (CLOSING ON CAP CAPACITOR SP SINGLE POLE MINIMUM NEMA TYPE 4 ENCLOSURE FOR EQUIPMENT AND GASKETED FITTINGS IN A AUXILIARY ITEMS UNIT, AS FOR EXAMPLE A STEAM GENERATOR OR AN AIR INCREASE IN FLOW) CB CIRCUIT BREAKER SPDT SINGLE POLE DOUBLE THROW CONDUIT SYSTEM. NORMALLY CLOSED PUSH BUTTON MAY NOT BE HANDLING UNIT, SHALL IMPLY THAT ANY AND ALL CD CONTROL DAMPER SPST SINGLE POLE SINGLE THROW SHOWN FLOW ACTUATED SWITCH (OPENING ON ASSOCIATED EQUIPMENT SHALL ALSO BE INSTALLED AND CKT CIRCUIT SS SELECTOR SWITCH COMPLETELY INCREASE IN FLOW) CLASS 1, DIVISION 1 AREA AS DEFINED BY NEC. ALL EQUIPMENT AND CONDUIT MAINTAINED PUSH BUTTON CL2 SV AREA TYPE 7A WIRED AS REQUIRED BY THE EQUIPMENT FURNISHED. CHLORINE SOLENOID VALVE SYSTEMS SHALL BE RATED FOR USE IN THIS AREA. ON TIME DELAY SWITCH (NORMALLY OPEN CP CONTROL PANEL SWB SWITCHBOARD INDICATES THAT ALL OR PART OF CIRCUIT MAY BE ROUTED NORMALLY CLOSED GEARED LIMIT WITH TIME DELAY CLOSING AFTER COIL IS CPT CONTROL POWER SWGR SWITCHGEAR IN DUCT BANK OR UNDERGROUND. CONDUIT SIZE SHOWN CLASS 1, DIVISION 2, GROUP C AND D (METHANE, GASOLINE) AS DEFINED BY NEC. SWITCH ENERGIZED) TRANSFORMER T THERMOSTAT, TIMER, AREA TYPE 7B ON ONE-LINE IS ABOVE GROUND AND/OR INSIDE OF EQUIPMENT AND CONDUIT SYSTEMS SHALL BE RATED FOR USE IN THIS AREA. ON TIME DELAY SWITCH (NORMALLY CS CONTROL STATION TOTALIZER STRUCTURE. SEE DUCT BANK SCHEDULE AND SECTIONS NORMALLY OPEN GEARED LIMIT CT CYCLE TIMER, CURRENT TACH TACHOMETER FOR CONDUIT SIZE OF UNDERGROUND PORTION OF CLOSED WITH TIME DELAY OPENING SWITCH TRANSFORMER TB TERMINAL BLOCK INDOOR, DRY, DIRTY AREA. REQUIRES MINIMUM NEMA TYPE 12 GASKETED CIRCUIT. AFTER COIL IS ENERGIZED) AREA TYPE 12 CTM CYCLE TIMER MOTOR TD TIME DELAY RELAY ENCLOSURES FOR ALL EQUIPMENT AND GASKETED FITTINGS IN CONDUIT SYSTEMS. OFF TIME DELAY SWITCH (NORMALLY 2/C TEMP HIGH VOLTAGE DRAWOUT AIR OR VACUUM CIRCUIT INDICATING LIGHT 2 CONDUCTOR TEMPERATURE OPEN WITH TIME DELAY OPENING AFTER 4"C 4" CONDUIT TQ TORQUE BREAKER. OUTDOOR AND INDOOR WET LOCATIONS SUBJECT TO CORROSION. CONDUIT SYSTEM COIL IS DE-ENERGIZED) DC DIRECT CURRENT TS TEMPERATURE SWITCH AREA TYPE 4X SHOULD BE PVC COATED RIGID GALVANIZED STEEL WITH PVC COATED FITTINGS, OFF TIME DELAY SWITCH (NORMALLY DM DAMPER MOTOR, DEMAND UG UNDERGROUND BOXES, AND STAINLESS STEEL HARDWARE. LOW VOLTAGE AIR CIRCUIT BREAKER, 3 POLE, 20 AMPERE. CLOSED WITH TIME DELAY CLOSING METER UPS UNINTERRUPTIBLE POWER CONTROL POWER TRANSFORMER AFTER COIL IS DE-ENERGIZED) DPDT DOUBLE POLE DOUBLE THROW SUPPLY DPST DOUBLE POLE SINGLE THROW V VOLTS TORQUE SWITCH (NORMALLY OPEN) DPS DIFFERENTIAL PRESSURE VA VOLT AMPERE SIZE 4 COMBINATION MAGNETIC MOTOR STARTER. SWITCH VLS VALVE LIMIT SWITCH TORQUE SWITCH (NORMALLY CLOSED) DS DISCONNECT SWITCH VM VOLTMETER MANUAL STARTER E ELECTRIC OPERATOR FOR W WHITE, WATTS LIMIT SWITCH (NORMALLY OPEN) CONTROL DAMPER OR VALVE WH WATTHOUR METER GENERAL REQUIREMENTS LOW VOLTAGE DRAWOUT AIR CIRCUIT BREAKER. WM WATT METER LIMIT SWITCH (NORMALLY OPEN, HELD EMH ELECTRICAL MANHOLE THE CONTRACTOR SHALL BE RESPONSIBLE FOR ROUTING ALL CONDUITS NOT SHOWN ETM ELAPSED TIME METER WP WEATHERPROOF FLOAT SWITCH (CLOSING ON RISING CLOSED) ON THE PLANS. THIS SHALL INCLUDE ALL CONDUITS SHOWN ON THE ONE-LINES AND EX EXISTING XFMR TRANSFORMER LEVEL) HOME-RUNS SHOWN ON THE PLAN DRAWINGS. CONDUITS SHALL BE ROUTED AS F XP EXPLOSION PROOF HIGH VOLTAGE DRAWOUT CONTACTOR. LIMIT SWITCH (NORMALLY CLOSED) FORWARD DEFINED IN THE SPECIFICATIONS. FS FLOW SWITCH Y YELLOW FLOAT SWITCH (OPENING ON RISING LIMIT SWITCH (NORMALLY CLOSED, HELD G GREEN, GROUND Z AUXILIARY RELAY LEVEL) OPEN) SPARE WIRES SHALL BE TAPED AND COILED. GFI GROUND FAULT INTERRUPTER ZS POSITION SWITCH FUSE AND DISCONNECT SWITCH. DIFFERENTIAL PRESSURE SWITCH GLS PRESSURE SWITCH (CLOSING ON GEARED LIMIT SWITCH IF EQUIPMENT SUPPLIED BY MANUFACTURER HAS A LARGER LOAD THAN VALUE SHOWN, (NORMALLY OPEN, CLOSING ON #8G RISING PRESSURE) #8 GROUND WIRE THE CABLE CONDUIT AND ELECTRICAL EQUIPMENT SHALL BE ENLARGED, AS REQUIRED, INCREASING DIFF.) H HIGH, HUMIDISTAT TO ACCOMODATE THE HIGHER VALUE. PRESSURE SWITCH (OPENING ON HH HANDHOLE SIZE 2 COMBINATION MAGNETIC MOTOR STARTER, DIFFERENTIAL PRESSURE SWITCH RISING PRESSURE) HMT HIGH MOTOR TEMPERATURE REVERSING OR 2 SPEED. (NORMALLY CLOSED, OPENING ON THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING PROPERLY SIZED HOA INCREASING DIFF.) HAND-OFF-AUTO STARTER OVERLOADS FOR EQUIPMENT FURNISHED. HOR HAND-OFF-REMOTE 24 VDC SURGE PROTECTION HP POTENTIAL TRANSFORMER. HORSEPOWER LIGHTING AND RECEPTACLE CIRCUITS DESIGNATED ON THE FLOOR PLANS ARE NOT HWCO HIGH WATER CUTOFF SHOWN ON THE ONE-LINES. CONDUCTORS FOR LIGHTING, RECEPTACLES, AND HZ HERTZ (CYCLE) MISCELLANEOUS 120VAC CIRCUITS SHALL BE MINIMUM NO. 12 AWG. CONDUIT FOR CURRENT TRANSFORMER. I/O INPUT/OUTPUT LIGHTING, RECEPTACLES, AND MISCELLANEOUS 120VAC CIRCUITS SHALL BE MINIMUM J JUNCTION BOX 3 4". KV KILOVOLT KVA KILOVOLT AMPERE IN AREAS WHERE THERE ARE OVERHEAD BRIDGE CRANES, HOISTS, ETC., NO CONDUITS KVAR KILOVAR SHALL BE RUN OVERHEAD THAT WILL INTERFERE WITH THE OPERATION OF THE SWITCH & OUTLET KW KILOWATT EQUIPMENT. SYMBOLS KWH KILOWATT HOUR L LOW, LEVEL A LA LIGHTNING ARRESTOR S SINGLE POLE SWITCH, A=SWITCH DESIGNATION LAN LOCAL AREA NETWORK A LP LIGHTING PANEL S2 TWO POLE SWITCH, A=SWITCH DESIGNATION LS LIMIT SWITCH, LEVEL A SWITCH S3 THREE-WAY SWITCH, A=SWITCH DESIGNATION CONDUIT & WIRING INSTALLATION LEGEND LWCO LOW WATER CUTOFF GENERAL NOTES A M S4 FOUR-WAY SWITCH, A=SWITCH DESIGNATION MAGNETIC MOTOR STARTER SOLID LINES INDICATE NEW WORK OR EQUIPMENT. A CONDUIT EXPOSED. SWP WEATHERPROOF SWITCH, A=SWITCH DESIGNATION MA MILLIAMPERE MCB DOTTED LINES INDICATE EXISTING WORK OR EQUIPMENT. A MAIN CIRCUIT BREAKER SKO KEY OPERATED SWITCH, A=SWITCH DESIGNATION MCC MOTOR CONTROL CENTER CONDUIT CONCEALED. DASHED LINES INDICATE FUTURE WORK OR EQUIPMENT. A MCM THOUSAND CIRCULAR MIL SXP EXPLOSION PROOF SWITCH, A=SWITCH DESIGNATION MD MOISTURE DETECTOR CONDUIT TURNING UP, CONDUIT TURNING DOWN. THIS IS A GENERAL LEGEND SHEET. SOME SYMBOLS AND ABBREVIATIONS MAY NOT BE MH MANHOLE, MOUNTING UTILIZED ON THIS SPECIFIC PROJECT. DUPLEX RECEPTACLE 120 VOLT HEIGHT CONDUIT PLUGGED FLUSH, CONDUIT CAPPED. MOV MOTOR OPERATED VALVE INFORMATION RELATED TO CIRCUIT IDENTIFICATION, WIRE & CONDUIT SIZES, AND ROUTING, IS 240V, 1 PHASE RECEPTACLE, TYPICAL MS MANUAL MOTOR STARTER ON THE FOLLOWING DRAWING TYPES. TYPICAL FOR HOME RUN TO BE ROUTED TO AMPERE RATING NOTED MSH MOTOR SPACE HEATER © LIGHTING PANEL L2 AND CONNECTED TO CIRCUIT N NEUTRAL ONE-LINE DIAGRAMS SHOW CIRCUIT IDENTIFICATION, WIRE QUANTITY AND SIZES, AND 3 480V, 3 PHASE WELDING RECEPTACLE, #5 (MINIMUM NO.
Recommended publications
  • Transportation Applications Transport Your Business to a Better Place: Leading the Race
    Product Range Guide Transportation Applications Transport your business to a better place: leading the race. Honeywell is committed to providing the right product for your application. Whether you need a standard product or a highly customized solution, our sales and engineering teams have decades of experience in the Transportation industry. We understand your applications and work diligently to ensure we provide a solution that optimally meets your technical and financial needs. Our unique combination of a broad product portfolio, deep technical capabilities and extensive application experience culminates into a powerful ability to meet your design needs. Table of Contents Introduction ................................... 2-3 Transportation product applications .......... 4-5 Speed and Direction Sensors ....................6 SMART Position Sensors .........................7 Non-contact Hall-effect Sensors & Pots .........8 Hall-Effect & Magnetoresistive Sensors. 9 Pressure and Vacuum Switches .............10-11 Board-Mount & Heavy-Duty Transducers ...12-13 Packaged Temperature Probes ..............14-15 Key and Rotary Switches ....................... 16 Shifters ........................................ 16 Push-Pull/eStop Switches ..................... 17 Hour Meters ................................... 17 MICRO SWITCH Toggle Switches .............. 18 MICRO SWITCH Basic Switches ................ 19 MICRO SWITCH Limit Switches .............20-21 Magnetoresistive Sensor ICs ................... 22 Hall-effect Digital/Linear Sensor ICs ..........
    [Show full text]
  • Typical 120V 3 Pole Contactor Example Pump Wiring Device
    CONTROL CIRCUIT & PILOT DEVICE LEGEND X1 X2 BACKGROUND PLAN AND ONE LINE SYMBOLS STARTER STARTER CONTROL 120 V SEAL-IN CONTACT FROM LIGHT TRANSFORMER STARTER CONTACTOR A1 "RUNNING" SYMBOL SYMBOL DESCRIPTION SYMBOL DESCRIPTION A-1 DESCRIPTION SYMBOL DESCRIPTION TAG THIS WIRE A1-1A (TYP) OFF R CONTROL SWITCH (SEL. OR P.B.) O SEE NOTE 2 LOW VOLTAGE DISCONNECT SWITCH PRESS. ACTUATED SWITCH SEE CIRCUITS FOR SPECIFIC TYPE HA START PUSHBUTTON 1 SELECTOR SWITCH OPERATOR STOP HAND AUTO FIELD MOUNTED 3-OL'S SEE CIRCUITS FOR SPECIFIC TYPE WITH FUNCTION SHOWN 1 A FLOAT SWITCH - FLOW SWITCH LOW VOLTAGE FUSE (BELOW 600V) FLOAT ACTUATED SWITCH (F) 1 TEMPERATURE - HUMIDISTAT SWITCH (F) ALL STARTERS SHALL BE FULL STARTER CONTACTOR (SUBSCRIPT = NO. OF STAGES) 1 CR-3 RV VOLTAGE NON-REVERSING UNLESS PUSHBUTTON COIL FOR MOTOR A1 MOMENTARY PUSHBUTTON FIELD 2 OTHERWISE INDICATED FLOW ACTUATED SWITCH A-1 LIMIT - PRESSURE - VACUUM SWITCH FVR (FVR) FULL VOLTAGE REVERSING OPERATOR-NORMALLY OPEN MOUNTED 3 (RV) REDUCED VOLTAGE SWITCH LOCATED AT (MCP) STARTER CUBICLE ELECTRICAL OR MECHANICAL ALTERNATOR 2S,2W (2S,2W) TWO SPEED, TWO WINDING MOMENTARY PUSHBUTTON STARTER CUBICLE (SEE WIRING) TEMP. ACTUATED SWITCH RELAY INTERLOCK TERMINAL STRIP OPERATOR-NORMALLY CLOSED FROM MAIN CONTROL TO MCP PANEL OVERLOAD SWITCH OR DEVICE 600V, 3 POLE MOLDED CASE CIRCUIT AUX. STARTER BREAKER, FRAME & RATING AS SHOWN LIMIT SWITCH- CONTACT TO PUSHBUTTON OPERATOR NORMALLY OPEN MAIN CONTROL A-3 SINGLE PHASE, FRACTIONAL HP MOTOR WITH MUSHROOM HEAD PANEL TERMINAL BOX 1/2 TO LOCATION INDICATED (SEE GEN. NOTE 4) LIMIT SWITCH- FIELD LOCATED STOP BUTTON A NORMALLY CLOSED STARTER NAMEPLATE SOLENOID VALVE 1 THREE PHASE LOAD WITH IDENTIFICATION (F) HIGH VOLTAGE FUSE (ABOVE 600 V) MAINTAINED PUSH-PULL EXAMPLE PUMP PHOTOCELL LINE VOLTAGE LIMIT SWITCH-NORMALLY CLOSED-HELD OPEN OPERATOR (TAG A1) 304 FT 10 TAG NO.
    [Show full text]
  • Kalamazoo, Michigan Water Reclamation Plant Electrical
    KALAMAZOO, MICHIGAN 710 AVIS DRIVE ANN ARBOR, MICHIGAN 48108 WATER RECLAMATION PLANT PHONE: (734) 665-6000 FAX: (734) 213-3003 ELECTRICAL UPGRADES SWITCHGEAR www.tetratech.com ELECTRICAL PROJECT LOCATION: CLIENT INFORMATION: E-001 ELECTRICAL LEGEND KALAMAZOO, MICHIGAN E-002 ELECTRICAL LEGEND, NOTES KALAMAZOO, MICHIGAN E-003 ELECTRICAL KALAMAZOO WATER RECLAMATION PLANT SITE E-004 ELECTRICAL SITE PLAN DEMOLITION E-005 ELECTRICAL ONE-LINE PROPOSED DEMOLITION Tt PROJECT No.: CLIENT PROJECT No.: E-006 ELECTRICAL ONE-LINE PROPOSED WORK 200-19743-19002 E-007 ELECTRICAL SWITCHGEAR FRONT ELEVATION E-008 ELECTRICAL ONE-LINE PROPOSED WORK E-009 ELECTRICAL ONE-LINE PROPOSED WORK PROJECT DESCRIPTION / NOTES: E-010 ELECTRICAL SYSTEM CONFIGURATION E-011 BACKGROUND PLAN PROPOSED WORK E-012 ELECTRICAL DEMOLITION, PROPOSED WORK E-013 PROPOSED ROOF PLAN E-014 PROPOSED ROOF PLAN MVUS NO.1 E-015 ELECTRICAL DETAILS E-016 ELECTRICAL DETAILS ISSUED: OWNER REVIEW 7-12-19 OWNER REVIEW 50% 7-25-19 OWNER REVIEW 100% 8-22-19 OWNER REVIEW FINAL 9-12-19 OWNER REVIEW FINAL 10-17-19 FOR BIDDING AND CONSTRUCTION 11-30-20 VICINITY MAP: PROJECT LOCATION 1 2 3 4 5 6 7 710 AVIS DRIVE www.tetratech.com F ANN ARBOR, MI 48108 BACKGROUND PLAN AND ONE LINE SYMBOLS I.S.A. STANDARD LETTER FUNCTIONS SYMBOL DESCRIPTION SYMBOL DESCRIPTION CONTROL SWITCH (SEL. OR P.B.) SYMBOL FIRST LETTER SUCCEEDING LETTERS PHONE: (734) 665-6000 FAX: 213-3003 SEE CIRCUITS FOR SPECIFIC TYPE FT TAG NO. (BALLOON) FOR DEVICE 10 INDICATED A ANALYSIS, ANALOG ALARM SEE CIRCUITS FOR SPECIFIC TYPE F FL B BURNER, FLAME BATCH FLOAT SWITCH - FLOW SWITCH CONTROL CIRCUIT & PILOT DEVICE LEGEND C CONDUCTIVITY, COMMAND CONTROL (FEEDBACK TYPE) TEMPERATURE - HUMIDISTAT SWITCH FT FOR POWER (SEE NOTE 2 ON D DENSITY, SPECIFIC GRAVITY T M (SUBSCRIPT=NO.
    [Show full text]
  • Pocket Program Kilowatt Exhibitors
    Megawatt Exhibitors 2016 IEEE International Power Modulator and High Voltage Conference San Francisco, CA – July 5–9, 2016 http://www.ipmhvc.org/2016 Pocket Program Kilowatt Exhibitors Sponsored By: Technically Co-Sponsored By: Watt Exhibitors Palace Hotel Conference Layout to second floor No access Registration Exhibits, Oral Breaks, Sessions Receptions Oral Sessions First Floor 1: Stangenes Industries, Inc. 18: Dean Technology, Inc. 1: Stangenes Industries, Inc. 18: Dean Technology, Inc. 2: 5S Components Inc. 19: Pearson Electronics 2: 5S Components Inc. 19: Pear son Electronics 3: JEMA Energy 20: Advanced Energy Inc 4: Pulse Power Solutions LLC 3: JEMA Energy 21: General Atomics 20: Advanced Energy Inc. 5: open 4: Pulse Power Solutions LLC 22: ITHPP21: General Atomics to first floor 6: Silicon Power Corporation 5: IEEE NPSS 23: GMW Associates22: ITHPP-Alcen 7: Pulse Power & Measurement Ltd. 6: Silicon Power Corporation 24: R&K Company Limited23: GMW Associates 8: CalRamic 7: Pulse Technologies LLC Power & Measurement 25: Barth Electronics, Inc.24: R&K Company Limited 9: Voltage Multipliers Inc. Ltd. 26: Diversified Technologies Inc.25: Barth Electronics, Inc. Poster Session C Short Courses, 10: open 8: CalRamic Technologies LLC 27: Behlke26: Diver sified Power Electronics LLC Technologies Inc. Satellite Meetings 11: Spellman High Voltage 9: Voltage Multipliers Inc. 28: Eagle Harbor Technologies, Inc. 27: Behlke Power Electronics LLC 12: L‐3 Applied Technologies, Inc. 10: open 29: TDK‐Lambda Americas28: Eagle Harbor Technologies, 13: Scandinova11: Spellman Systems AB High Voltage 30: HVR Advanced Power Components, Inc. Poster Session B 14: open12: L-3 Applied Technologies, Inc. Inc.29: TDK-Lambda Americas 15: Lockheed Martin13: Scandino va Systems AB T1:30: HVR Open Advanced Power Poster Session A 16: Kanthal‐Globar, Sandvik T2: TREK, INC.
    [Show full text]
  • Background Plan and One Line Symbols Wiring Device
    1 2 3 4 5 6 7 BACKGROUND PLAN AND ONE LINE SYMBOLS I.S.A. STANDARD LETTER FUNCTIONS GENERAL NOTES: SYMBOL DESCRIPTION SYMBOL FIRST LETTER SUCCEEDING LETTERS 1. ELECTRICAL MATERIALS AND EQUIPMENT ITEMS SHOWN IN LIGHT LINE WEIGHT ON THE DRAWINGS ARE CONTROL SWITCH (SEL. OR P.B.) SEE CIRCUITS FOR SPECIFIC TYPE A ANALYSIS, ANALOG ALARM B BURNER, FLAME BATCH EXISTING ITEMS TO REMAIN. ELECTRICAL MATERIALS AND EQUIPMENT ITEMS SHOWN IN HEAVY LINE F FL SEE CIRCUITS FOR SPECIFIC TYPE FLOAT SWITCH - FLOW SWITCH C CONDUCTIVITY, COMMAND CONTROL (FEEDBACK TYPE) WEIGHTS ARE NEW THIS CONTRACT. D DENSITY, SPECIFIC GRAVITY 2. ITEMS SHOWN CROSSHATCHED ON THE DRAWINGS ARE EXISTING ITEMS TO BE REMOVED. T M TEMPERATURE - HUMIDISTAT SWITCH (SUBSCRIPT=NO. OF STAGES) www.tetratech.com E VOLTAGE PRIMARY ELEMENT 3. INSTALL A SINGLE CONDUCTOR INSULATED (RHW, THHN, OR XHHW) COPPER GROUND WIRE IN EACH TEL: 734.665.6000 F FLOW RATE RATIO Ann Arbor, MI 48108 F L P V LIMIT (PROXIMITY TYPE) PRESSURE - VACUUM SWITCH CONDUIT, SIZE AS SHOWN ON DRAWINGS OR AS A MINIMUM PER THE NATIONAL ELECTRICAL CODE. THIS G GAGING GLASS GROUND WIRE SHALL BE CONNECTED AT EACH END TO THE EQUIPMENT GROUND. CONDUIT SHALL BE ELECTRICAL OR MECHANICAL ALTERNATOR (SEE WIRING) 710 Avis Drive, Suite 100 ALT H HAND, MANUAL HIGH 3/4" MIN. I CURRENT INDICATE 4. THE FOLLOWING COMPONENT IDENTIFICATION SHALL BE USED AS OS OVERLOAD SWITCH OR DEVICE J POWER SCAN APPROPRIATE: TB TERMINAL BOX K TIME, TIME SCHEDULE CONTROL (NO FEEDBACK) L LEVEL, LIGHT LOW 4.1. (F) FIELD MOUNTED NOT AT STARTER OR OTHER CONTROL PANELS.
    [Show full text]
  • Electric Switches; Relays; Selectors
    H01H CPC COOPERATIVE PATENT CLASSIFICATION H ELECTRICITY (NOTE omitted) H01 BASIC ELECTRIC ELEMENTS (NOTES omitted) H01H ELECTRIC SWITCHES; RELAYS; SELECTORS; EMERGENCY PROTECTIVE DEVICES (contact cables H01B 7/10; electrolytic self-interrupters H01G 9/18; emergency protective circuit arrangements H02H; switching by electronic means without contact-making H03K 17/00) NOTES 1. This subclass covers (in groups H01H 69/00 - H01H 87/00) devices for the protection of electric lines or electric machines or apparatus in the event of undesired change from normal electric working conditions, the electrical condition serving directly as the input to the device. 2. This subclass does not cover bases, casings, or covers accommodating two or more switching devices or for accommodating a switching device as well as another electric component, e.g. bus-bar, line connector. Those bases, casings or covers are covered by group H02B 1/26. 3. In this subclass, the following terms or expressions are used with the meanings indicated : • "relay" means a switching device having contacts which are operated from electric inputs which supply, directly or indirectly, all the mechanical energy necessary to cause both the closure and the opening of the contacts; • "driving mechanism" refers to the means by which an operating force applied to the switch is transmitted to the moving contact or contacts; • "operating" is used in a broader sense than "actuating" which is reserved for those parts not touched by hand to effect switching; • "acting" or "action" means a self-induced movement of parts at one stage of the switching. These connotations apply to all parts of the verbs "to operate", "to actuate" and "to act" and to words derived therefrom, e.g.
    [Show full text]
  • Table of Contents Pressure Switch Selection Guide
    Table of Contents Pressure Switch Selection Guide ....................................................................................................... 5 Electronic Pressure Switch ....................................................................................... 5 Mechanical Pressure ................................................................................................ 8 Pressure Switch Application Example ...................................................................... 9 Series ZSE30/ISE30 High Precision, 2-color Display Digital Pressure Switch.................................. 12 Features.................................................................................................................... 13 Series ZSE30/ISE30 High Precision, 2-color Display Digital Pressure Switch........ 15 How to Order ............................................................................................................ 15 Specifications............................................................................................................ 16 Setting....................................................................................................................... 17 Dimensions ............................................................................................................... 21 Precautions............................................................................................................... 24 Series ZSE40/ISE40 High Precision, Digital Pressure Switch..........................................................
    [Show full text]
  • I-010 Panel Layout & Wiring Diagram
    CITY OF ROCKLEDGE 201 EAST PINE STREET, SUITE 1000 ORLANDO, FL 32801-2763 SCADA, WIFI AND VIDEO SURVEILLANCE TEL: (407) 839-3955 FAX: (407) 839-3790 PHASE II IMPLEMENTATION www.tetratech.com PROJECT LOCATION: CLIENT INFORMATION: 1700 JACK OATES BLVD. CITY OF ROCKLEDGE ROCKLEDGE, FL 32955 3100 JACK OATES BLVD. ROCKLEDGE, FL 32955 Sheet List Table Sheet Number Sheet Title Tt PROJECT No.: CLIENT PROJECT No.: G-000 COVER 200-53784-18005 E-001 LEGEND E-002 OVERALL ELECTRICAL SITE PLAN E-003 OPS & RAS ELECTRICAL PLANS PROJECT DESCRIPTION / NOTES: E-004 HW & DW ELECTRICAL PLANS IMPLEMENT PHASE II OF THE ROCKLEDGE SCADA MASTER PLAN E-005 CHEM & GEN ELECTRICAL PLANS CONSISTING OF SCADA, WIFI & VIDEO SURVEILLANCE FOR THE WASTEWATER RECLAMATION FACILITY E-006 ELECTRICAL DETAILS E-007 ELECTRICAL DETAILS I-001 INSTRUMENTATION LEGEND I-002 PROPOSED PLANT NETWORK ARCHITECTURE ISSUED: I-003 PROPOSED WIFI NETWORK ARCHITECTURE BID SET I-004 WiFi COVERAGE PLAN I-005 PROPOSED VIDEO SURVEILLANCE ARCHITECTURE I-006 PROPOSED VIDEO SURVEILLANCE COVERAGE PLAN I-007 INSTRUMENTATION DETAILS I-008 INSTRUMENTATION DETAILS I-009 PANEL LAYOUT & WIRING DIAGRAM VICINITY MAP: N PROJECT LOCATION OCTOBER 2019 1 2 3 4 5 6 7 BACKGROUND PLAN AND ONE LINE SYMBOLS CONTROL CIRCUIT & PILOT DEVICE LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION CONTROL SWITCH (SEL. OR P.B.) LOW VOLTAGE DISCONNECT SWITCH O SEE CIRCUITS FOR SPECIFIC TYPE PRESS. ACTUATED SWITCH H A www.tetratech.com SELECTOR SWITCH OPERATOR F F FL SEE CIRCUITS FOR SPECIFIC TYPE WITH FUNCTION SHOWN ORLANDO, FL 32801 FLOAT SWITCH - FLOW SWITCH LOW VOLTAGE FUSE (BELOW 600V) FLOAT ACTUATED SWITCH TEMPERATURE - HUMIDISTAT SWITCH T M 1 ALL STARTERS SHALL BE FULL (SUBSCRIPT = NO.
    [Show full text]
  • PRELIMINARY Book of Abstracts
    2016 IEEE Power Modulator and High Voltage Conference Tuesday, July 5, 2016 - Saturday, July 9, 2016 <a href=http://www.sfpalace.com/>Palace Hotel San Francisco</a> Book of Abstracts ii Contents Daily Operation of Z: An 80 Terawatt, 36 Module Pulsed Power Driver 3 .......... 1 Core and copper loss effects on the stepped impedance transmission line pulse generator 99 ............................................... 1 Charge trapping/detrapping characteristics and lifetime of solid dielectrics 88 . 1 Design of Bipolar Pulse Generator Topology Base on Marx Generator Supplied by Double Power 124 .......................................... 2 Two-dimensional numerical modeling of electric field and correlation to breakdown –Area scaling 10 ........................................... 2 Design and testing of a compact low impedance Marx generator with quasi rectangular pulse 64 ............................................ 3 Energy Consumption Characteristics of Pulsed Arc Discharge in High Pressure Carbon Dioxide up to Supercritical Phase 162 ........................... 3 Initial Evaluation of the Load Current Multiplier Concept on the Sandia Z Accelerator 74 4 An AC Arc Discharge Model for Ice-Covered FRP Live-Line Tools 185 ........... 4 Characterization of Double-Positive Metamaterials for Advanced Applications 184 . 5 Repetitive pulse X-rays generator based on all solid state pulsed power source 258 . 6 Seismic Wave Characteristic of Ground Surface Layer Produced by Pulsed Discharges in Closed Water Domain 42 .................................. 6 The Anaysis of Time to Breakdown in Various Gas Insulation Systems 163 . 7 Study of the deterioration of conductive coatings used in form-wound motor coils by fret- ting wear tests 299 ...................................... 7 Influence of Impulse Waveform Parameters on the Breakdown Voltage in SF6 Highly Inho- mogeneous Electric Field 246 ................................ 8 HIGH-FIELD EXCITED FLASHOVER ACROSS SOLID DIELECTRICS IN VACUUM: MECH- ANISM AND SUPPRESSION 139 .............................
    [Show full text]