I-010 Panel Layout & Wiring Diagram
Total Page:16
File Type:pdf, Size:1020Kb
CITY OF ROCKLEDGE 201 EAST PINE STREET, SUITE 1000 ORLANDO, FL 32801-2763 SCADA, WIFI AND VIDEO SURVEILLANCE TEL: (407) 839-3955 FAX: (407) 839-3790 PHASE II IMPLEMENTATION www.tetratech.com PROJECT LOCATION: CLIENT INFORMATION: 1700 JACK OATES BLVD. CITY OF ROCKLEDGE ROCKLEDGE, FL 32955 3100 JACK OATES BLVD. ROCKLEDGE, FL 32955 Sheet List Table Sheet Number Sheet Title Tt PROJECT No.: CLIENT PROJECT No.: G-000 COVER 200-53784-18005 E-001 LEGEND E-002 OVERALL ELECTRICAL SITE PLAN E-003 OPS & RAS ELECTRICAL PLANS PROJECT DESCRIPTION / NOTES: E-004 HW & DW ELECTRICAL PLANS IMPLEMENT PHASE II OF THE ROCKLEDGE SCADA MASTER PLAN E-005 CHEM & GEN ELECTRICAL PLANS CONSISTING OF SCADA, WIFI & VIDEO SURVEILLANCE FOR THE WASTEWATER RECLAMATION FACILITY E-006 ELECTRICAL DETAILS E-007 ELECTRICAL DETAILS I-001 INSTRUMENTATION LEGEND I-002 PROPOSED PLANT NETWORK ARCHITECTURE ISSUED: I-003 PROPOSED WIFI NETWORK ARCHITECTURE BID SET I-004 WiFi COVERAGE PLAN I-005 PROPOSED VIDEO SURVEILLANCE ARCHITECTURE I-006 PROPOSED VIDEO SURVEILLANCE COVERAGE PLAN I-007 INSTRUMENTATION DETAILS I-008 INSTRUMENTATION DETAILS I-009 PANEL LAYOUT & WIRING DIAGRAM VICINITY MAP: N PROJECT LOCATION OCTOBER 2019 1 2 3 4 5 6 7 BACKGROUND PLAN AND ONE LINE SYMBOLS CONTROL CIRCUIT & PILOT DEVICE LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION CONTROL SWITCH (SEL. OR P.B.) LOW VOLTAGE DISCONNECT SWITCH O SEE CIRCUITS FOR SPECIFIC TYPE PRESS. ACTUATED SWITCH H A www.tetratech.com SELECTOR SWITCH OPERATOR F F FL SEE CIRCUITS FOR SPECIFIC TYPE WITH FUNCTION SHOWN ORLANDO, FL 32801 FLOAT SWITCH - FLOW SWITCH LOW VOLTAGE FUSE (BELOW 600V) FLOAT ACTUATED SWITCH TEMPERATURE - HUMIDISTAT SWITCH T M 1 ALL STARTERS SHALL BE FULL (SUBSCRIPT = NO. OF STAGES) ENGINEERING BUSINESS NO. 2429 RV VOLTAGE NON-REVERSING UNLESS 2 OTHERWISE INDICATED FLOW ACTUATED SWITCH MOMENTARY PUSHBUTTON L P V LIMIT - PRESSURE - VACUUM SWITCH FVR (FVR) FULL VOLTAGE REVERSING OPERATOR-NORMALLY OPEN 3 (RV) REDUCED VOLTAGE ALT ELECTRICAL OR MECHANICAL ALTERNATOR 2S,2W (2S,2W) TWO SPEED, TWO WINDING 201 EAST PINE STREET, SUITE 1000 (SEE WIRING) TEMP. ACTUATED SWITCH MOMENTARY PUSHBUTTON OPERATOR-NORMALLY CLOSED OVERLOAD SWITCH OR DEVICE 600V, 3 POLE MOLDED CASE CIRCUIT OS BREAKER, FRAME & RATING AS SHOWN LIMIT SWITCH- PUSHBUTTON OPERATOR PHONE: (407) 839-3955 FAX: (407) 839-3790 NORMALLY OPEN A-3 SINGLE PHASE, FRACTIONAL HP MOTOR WITH MUSHROOM HEAD TB TERMINAL BOX 1/2 TO LOCATION INDICATED (SEE GEN. NOTE 4) LIMIT SWITCH- A FIELD LOCATED STOP BUTTON SOLENOID VALVE 1 THREE PHASE LOAD WITH IDENTIFICATION NORMALLY CLOSED (F) PC HIGH VOLTAGE FUSE (ABOVE 600 V) MAINTAINED PUSH-PULL BID SET PHOTOCELL LINE VOLTAGE LIMIT SWITCH-NORMALLY CLOSED-HELD OPEN OPERATOR Banks R. Wason, P.E. 304 FT TAG NO. (BALLOON) FOR DEVICE INDICATED ITEM NO. INTERCOM EQUIPMENT 10 LIMIT SWITCH-NORMALLY P.E. No. 73973, FL INTERCOMMUNICATION SYSTEM OPEN-HELD CLOSED MAINTAINED STOP-START A WS LB FOR POWER (SEE GEN. NOTE 4) AMPLIFIER - WALL STATION - LINE BALANCE A-3 3/4"C(2/C#18 SHLD.)CONDUIT AND WIRE PUSHBUTTON OPERATOR 201 East Pine Street, Suite 1000 FT MCP OR RUN FROM DEVICE INDICATED TO Orlando, Florida 32801 E DS INTERCOMMUNICATION DESK SET 10 CP-1 LOCATION INDICATED LATCHING CABLE SWITCH Engineering Business No. 2429 INTERCOM. SPEAKER (SURFACE MTD.) CAPACITOR, 3 PHASE, SIZE AS INDICATED ________________________ TIME-DELAY FUSE SOLENOID OR CLUTCH DISCONNECT SWITCH DATE ______________ INTERCOM. SPEAKER (CEILING LAY-IN) F C (F) = FUSED (C) = CIRCUIT BREAKER R PUSH-TO-TEST CR CONTROL RELAY COIL TELEPHONE OUTLET - 1"C.(2)CAT 6 CABLES MAGNETIC STARTER 1 INDICATING LIGHT TO NETWORK RACK (BACKGROUND DRAWINGS ONLY) WELDING RECEPTACLE - NEMA L9-50R COMBINATION MAGNETIC STARTER CONTROL RELAY 600V, 2P, 3W, SIMPLEX SIZE 2 FUSED UNLESS NOTED (CIRCUIT BREAKER) CONTACT-NORMALLY OPEN MAINTAINED STOP- MOMENTARY START COMBINATION LIGHTING CONTACTOR PUSHBUTTON (JOG) HS INTERCOM HANDSET - SURFACE MOUNTED LC WITH HAND-OFF-AUTO SWITCH CONTROL RELAY WITH REMOTE SPEAKER AMPLIFIER CONTACT-NORMALLY CLOSED VC INTERCOM VOLUME CONTROL R MANUAL STARTER (R) = REVERSING ZERO SPEED OR ANTI- CR PLUGGING SWITCH CP L INTERCOM SPEAKER - SURFACE MOUNTED CONTROL PANEL TWO COIL LATCHING RELAY INTERCOM HANDSET - FLUSH MOUNTED CR LOCAL TERMINALS WITH HS WITH REMOTE SPEAKER AMPLIFIER TCP TEMPERATURE CONTROL PANEL U EXTERNAL WIRING AS NOTED (LIGHTING PANEL, CONTROL PANEL, DISTRIBUTION PANEL ETC.) WALL MOUNTED 1/8 UNIT HEATER, 1/8 HORSEPOWER T UH-19 TIMING RELAY COIL ETI ELAPSED TIME INDICATOR JUNCTION BOX BUS DUCT 600 VOLT FEEDER BUS DUCT D JB (AMPERAGE AS INDICATED) TIMED CLOSED CONTACT INST. ON ENERGIZATION HEATER LIGHTNING ARRESTOR TIMING RELAY INSTANTANEOUS CONTACTS TIMED OPEN CONTACT TRANSFORMER A-3 LOW VOLTAGE HOME RUNS INST. 120/208 V 120/240 V (SEE GEN. NOTE 4) ON ENERGIZATION CONDUIT WITH CONDUIT SEAL FITTING NEMA 4 WATERTIGHT TIMED OPEN CONTACT ON DE-ENERGIZATION CONDUIT EXPOSED NEMA 4X WATERTIGHT AND CORROSION PROOF TIMED CLOSED CONTACT ON DE-ENERGIZATION CONDUIT CONCEALED EXPLOSION PROOF - NEMA 7 CLASS I, DIVISION I, GROUP D BY EXPLOSION PROOF - X1 X2 120 VAC TRANSFORMER DB DIRECT BURIED CONDUIT NEMA 9 CLASS II, DIVISION 1 UG DIRECT BURIED CABLE K KEYLOCK OE OVERHEAD LINE SD SMOKE DETECTOR EXIT EXIT LIGHT LIGHT FIXTURE 1 2 3 CONCRETE ENCASED DUCT BANK, WITH C CABLE LOCATIONS AND SPARE DUCTS AS 4 5 6 INDICATED ON DRAWINGS WALL MOUNTED LIGHT FIXTURE CCTV SECURITY CAMERA HIGH INTENSITY DISCHARGE LIGHT DC MAGNETIC DOOR CONTACT EM EMERGENCY BATTERY PACK GROUND POLE MOUNTED LIGHT FIXTURE DESCRIPTION DATE ESCAMILLAACERO, ANGELA - MARK B GENERAL NOTES: LEGEND 1. ELECTRICAL MATERIALS AND EQUIPMENT ITEMS SHOWN IN LIGHT LINE WEIGHTS ON THE DRAWINGS ARE EXISTING ITEMS TO REMAIN. ELECTRICAL ELECTRICAL MATERIALS AND EQUIPMENT ITEMS SHOWN IN HEAVY LINE WEIGHTS ARE NEW CITY OF ROCKLEDGE THIS CONTRACT. 2. FOR ITEMS INDICATED AS "FIELD LOCATE" CHECK DRAWINGS OF OTHER TRADES (IN PARTICULAR PIPING AND STRUCTURAL) FOR INTERFERENCE AND FOR LOCATIONS OF MOUNTING FLANGES, CONNECTION POINTS, ETC. Project No.: 200-53784-18005 A P:\IER\53784\200-53784-18005\CAD\SHEETFILES\E-001 LEGEND.DWG Designed By: DK - Drawn By: DK Checked By: BRW E-001 Copyright: Tetra Tech 10/24/2019 4:52:15 PM Bar Measures 1 inch 1 2 3 4 5 6 7 www.tetratech.com F ORLANDO, FL 32801 ENGINEERING BUSINESS NO. 2429 201 EAST PINE STREET, SUITE 1000 CCTV CCTV PHONE: (407) 839-3955 FAX: (407) 839-3790 BID SET Banks R. Wason, P.E. P.E. No. 73973, FL 201 East Pine Street, Suite 1000 Orlando, Florida 32801 E Engineering Business No. 2429 ________________________ DATE ______________ D CCTV BY C ESCAMILLAACERO, ANGELA - DESCRIPTION DATE MARK B N SITE PLAN ELECTRICAL CITY OF ROCKLEDGE Project No.: 200-53784-18005 A P:\IER\53784\200-53784-18005\CAD\SHEETFILES\E-002 OVERALL ELECTRICAL SITE PLAN.DWG Designed By: DK - Drawn By: DK Checked By: BRW CCTV E-002 Copyright: Tetra Tech 10/24/2019 4:52:22 PM Bar Measures 1 inch 1 2 3 4 5 6 7 FOR CONTINUATION 1"C(CAT 6) TO EXISTING SEE DWG.~ E-002 NETWORK RACK N www.tetratech.com F ORLANDO, FL 32801 CCTV DC DC 0 4'-0" 8'-0" 16'-0" ENGINEERING BUSINESS NO. 2429 1"C(2#14,1#14G) TO SCALE: 1/8" = 1'-0'' EXISTING NETWORK RACK 201 EAST PINE STREET, SUITE 1000 PHONE: (407) 839-3955 FAX: (407) 839-3790 EXISTING NETWORK RACK BID SET WIFI ANTENA Banks R. Wason, P.E. P.E. No. 73973, FL CCTV 201 East Pine Street, Suite 1000 Orlando, Florida 32801 E Engineering Business No. 2429 1"C(CAT 6) TO 40-CP-01 ________________________ 1"C(COAX) TO 40-CP-01 DATE ______________ DC D DC 1"C(2#14,1#14G) TO DC 40-CP-01 1"C(4#14,1#14G) TO DC EXISTING NETWORK RACK EXISTING PANEL 'L5' (G.E. SERIES 'A') EXISTING 1P.-20A SPARE BREAKER, CIRCUIT 17 EXISTING 40-CP-01 BY EXISTING PANEL T 'L5A' (G.E. SERIES 'A') PROVIDE 2P.-20A BREAKERS IN SPACES 5,7 & 9,11 EXISTING MCC-M1 C ESCAMILLAACERO, ANGELA - FOR CONTINUATION ~ SEE DWG. E-002 1"C(2#14,1#14G) TO 40-CP-01 DESCRIPTION 1-1/2"C(4#6,1#6G) L5A-5,7,9,11 EXISTING PANEL 'L1' 1"C(2#10,1#10G) L5-17 DATE DC DC CCTV MARK B 1"C(CAT 6) TO 40-CP-01 RAS/WAS PUMP STATION ELECTRICAL PLAN SCALE: 1/4"=1'-0" CITY OF ROCKLEDGE 1"C(2#14,1#14G) TO ELECTRICAL PLANS EXISTING NETWORK RACK RAS/WAS PUMP STATION OPERATIONS BUILDING & DC Project No.: 200-53784-18005 A P:\IER\53784\200-53784-18005\CAD\SHEETFILES\E-003 OPS & RAS ELECTRICAL PLANS.DWG Designed By: DK - Drawn By: DK Checked By: BRW OPERATIONS BUILDING ELECTRICAL PLAN E-003 SCALE: 1/4"=1'-0" Copyright: Tetra Tech 10/24/2019 4:52:31 PM Bar Measures 1 inch 1 2 3 4 5 6 7 TO CAMERA FOR CONTINUATION TO BLOWER SEE DWG.~ E-002 BUILDING FOR CONTINUATION N SEE DWG.~ E-002 EXISTING PANEL 'L4' WIFI ANTENA WIFI ANTENA www.tetratech.com (WESTINGHOUSE 'PRL1') ORLANDO, FL 32801 F EXISTING POLYMER CCTV CONTROL PANEL 0 4'-0" 8'-0" 16'-0" JB ENGINEERING BUSINESS NO. 2429 1"C(2#14,1#14G) TO DC SCALE: 1/8" = 1'-0'' 1"C(CAT 6) TO 10-CP-01 130-CP-01 1"C(CAT 6) TO 130-CP-01 1"C(COAX) 1"C(COAX) 201 EAST PINE STREET, SUITE 1000 TO 10-CP-01 DC TO 130-CP-01 EXISTING PANEL 'L3' 1"C(2#14,1#14G) TO 10-CP-01 EXISTING PHONE: (407) 839-3955 FAX: (407) 839-3790 DC 1"C(2-2/C#16TSP) 130-CP-01 TO 130-CP-01 1"C(2#14,1#14G) TO 10-CP-01 DC BID SET Banks R.