Ultrasonic Metering Overview Brochure

Total Page:16

File Type:pdf, Size:1020Kb

Ultrasonic Metering Overview Brochure Connected Industrial Connected Plant HONEYWELL: ULTRASONIC METERINGConnected SOLUTIONS Worker Industrial Cyber Security Connected Industrial Connected Plant Connected Worker Industrial Cyber Security Made to Measure Superior Technology for Unrivaled Accuracy A portfolio of natural gas metering systems and services Designed in the lab to perform in the realities of the field, our meters use tailored to the demanding needs of the midstream. patented six- or eight-path configurations for detailed flow profile recognition, superb noise immunity, and unrivaled pressure and gas velocity abilities. Saving Your Operation Honeywell ultrasonic metering solutions minimize Q.Sonicplus: The multipath custody Manifolds, elbows, reducers, short inlets and Connect you meters to our Meascon software, • Up to $1 million a year uncertainty, maximize reliability and boost efficiency transfer standard other elements all have a significant effect on the meanwhile, and you can benefit from continuous by eliminating a 0.5% A patented path configuration undetected error in gas to meet the challenges of a tough business profile of the gas flow. Our unique path layouts 24/7 monitoring, extending periods between measurement 1 environment. We provide the accuracy and insight enables measurement of both accurately detect swirl and asymmetry and calibrations and eliminating unnecessary • $112,320 a year with you need to deal with low prices, volatility, a broad swirl and asymmetry to ensure you get the certainty you need with the maintenance. reduced uncertainty of hydrocarbon mix, and increasing numbers of deliver excellent profile pipework you have. 0.08 with Honeywell’s 2 recognition and Built to Last market-leading USMs pipelines, some with contaminated natural gas. Fiscal measurements are fully compliant with diagnostic possibilities. Honeywell meters offer enhanced corrosion • $50,000 by extending With better solutions for custody transfer and ISO17089-1, AGA9 and OIML R137-, with recalibration intervals from Users can choose to resistance using high-grade, fully encapsulated, verification, we help gas transmission companies, accuracy class 0.5 for the flagship Q.Sonic,max one to two years include internal pressure and temperature intrinsically safe titanium transducers. When it’s • underground gas storage businesses and the even in conditions of severe disturbance. 75% lower Opex per measurement, too. needed, though, you can quickly clean or replace meter from fewer failures, LNG industry run more profitable operations: them without shutting down or depressurizing unplanned shutdowns TwinSonicplus: Two independent Reliability to Count On and field servicing • Eliminating the costs of undetected measurements in a single device Reflective paths and advanced diagnostics help the system. • 45% Capex savings from measurement errors One meter body houses a meter for custody detect liquid formation or build-up on the pipe No moving parts to wear out or require lubrication installation costs, smaller • Reducing downtime footprints and single-body transfer with an additional, walls quicker. and no pressure drop to add to compressors’ verification • Lowering maintenance costs totally independent Only possible with reflective paths, pipe wall loads, Honeywell ultrasonic meters offer years With the world’s best ultrasonic meters (USMs) measurement to condition monitoring prevents inaccurate readings. of trouble-free, cost-effective operation. and software you can reduce product that’s lost check the primary Reducing uncertainty by as much as 0.05% against and unaccounted for, reduce recalibrations, reading. It’s a smaller, other ultrasonic meters, our meters could save implement condition-based maintenance, and more efficient answer for you more than $70,000 a year.2 diagnose problems sooner to avoid costly repairs. applications where a second measurement is vital for on-going monitoring and verification. A Connected Portfolio A Versatile Portfolio Meascon™ Software for measurement control Connecting the midstream, our meters offer a Honeywell ultrasonic meters offer market- Providing 24/7 condition-based monitoring network connection to cut costs, improve leading solutions for every measurement need. of the measurement systems, Meascon delivers reliability and boost safety. With the ability to Helping you achieve the perfect balance of a diagnostic dashboard for real-time visibility and configure, diagnose and generate meter health performance and efficiency, our range of options control of all your gas metering stations. reports remotely, plants can centralize and supporting technology give you the certainty monitoring and control to cut your operation requires. maintenance costs by 75%. Q.Sonicmax: The new benchmark in accuracy for custody transfer The world’s first eight-path meter combining both reflective and direct measurements delivers the lowest possible uncertainty in the most demanding operations. Where accuracy is vital, Q.Sonicmax delivers industry-leading performance. The Best of Both Worlds: The Q.Sonicmax A Custody Transfer plus With a unique configuration combining reflective and Standard: The Q.Sonic direct paths, Honeywell’s flagship meter delivers unbeatable A robust, reliable multi-path favorite in ultrasonic metering. performance in ultrasonic measurement. The Q.Sonicmax is uncompromising on uncertainty. Features With many of the features of our flagship, the Features Eight paths provide OIML accuracy class 0.5 even The Q.Sonicmax offers unmatched performance: Q.Sonicplus features six reflective paths in a patented • 6-path reflective technology in cases of severe disturbance for the highest configuration to deliver practical performance in • 8-path, reflective • No moving parts • Flow profile detection with swirl and asymmetry possible certainty in every situation. the field. Measuring swirl and asymmetry, it and direct technology • No pressure drop measurement delivers excellent profile recognition and diagnostic The meter uses two swirls paths (double refection) • Flow profile • Internal temperature sensor • Bi-directional possibilities, as well as an option to include internal for linearity and stability, together with six direct detection with swirl • All-metal-encapsulated intrinsically safe measurement pressure and temperature measurements. paths for enhanced robustness. With the best flow and asymmetry transducers • OIML R137-1 2012 profile recognition available, it has superb noise measurement Providing cost-effective fiscal metering, the accuracy class 0.5 • No moving parts immunity and insensitivity to installation effects. Q.Sonicplus eliminates the need for extensive • Internal temperature • No pressure drop A 5D inlet also means a reduced footprint. It’s the • ISO 17089-1:2010 commissioning, installation and health checks, sensor • Bi-directional measurement best answer for custody transfer in high CO2 • MID approved with intelligent health diagnostics. Using Path Configuration • All-metal-encapsulated • SonicExplorer PC software for configuration, Two pairs of double and applications, where there is high valve noise or other • AGA 9 compliant reflective paths, it also facilitates fast detection Path Configuration intrinsically safe two single refection paths challenging applications where accuracy is vital. of liquids and dirt in the pipeline. diagnostics and health monitoring Three pairs of direct provide a symmetrically cross X paths in the same transducers As well as providing excellent swirl and asymmetry Like the Q.Sonicmax all electronics are located in a • OIML R137-1 weighted measurement. plane and two swirl (double The subtraction of the measurement, the meter’s reflective paths enable flame-proof housing with a separate connection • AGA 9 compliant reflection) paths result in SonicExplorer paired paths provides an sophisticated acoustic pipe wall condition monitoring for improved With the SonicExplorer PC-based software, users compartment for field wiring. A modular hardware • MID approved. indication of asymmetric imaging and interrogation reliability. It also offers internal pressure and design with a free slot means the device is also flow along the mirror plane of the gas stream. can configure, diagnose and monitor meters locally of the paths as an additional temperature sensors for more accurate Reynolds or remotely. With health monitoring from office, ready to tackle your future requirements. diagnostic feature. number calculations and dynamic body correction, you can reduce field service trips and visits to giving you additional measurement confidence. hazardous areas, boosting efficiency and safety. Repeatable, accurate and reliable even when The intuitive software enables users to analyze The First Choice for a Second Opinion: process conditions vary from calibrated conditions, real-time and historical meter health and max plus the Q.Sonic is field-proven and globally certified. performance data, as well as conduct off-line The TwinSonic data analysis. With SonicExplorer you can also Simple, Powerful, Connected quickly capture and share a complete log of all Two independent measurements; a single solution. Easy to maintain and offering intuitive operation, diagnostic, configuration and spectral noise max the Q.Sonic features extended diagnostics and plus analysis data. The TwinSonic is a two-in-one redundant multi- Features a simulator for training. Easy connectivity with a path ultrasonic gas meter for custody transfer • Two totally independent flow meters in one meter range of traditional and modern
Recommended publications
  • Biomass-Derived Hydrogen from a Thermally Ballasted Gasifier
    Proceedings of the 2002 U.S. DOE Hydrogen Program Review NREL/CP-610-32405 Biomass-Derived Hydrogen from a Thermally Ballasted Gasifier Robert C. Brown, Glenn Norton, Andy Suby, Jerod Smeenk, Keith Cummer, and Josh Nunez Center for Sustainable Environmental Technologies Iowa State University Ames, IA 50011-3020 INTRODUCTION The goal of this project is to optimize performance of an indirectly heated gasification system that converts switchgrass into hydrogen-rich gas suitable for powering fuel cells. We have developed a thermally ballasted gasifier that uses a single reactor for both combustion and pyrolysis. Instead of spatially separating these processes, they are temporally isolated. The producer gas is neither diluted with nitrogen or the products of combustion. The heat released during combustion at 850°C is stored as latent heat in the form of molten salt sealed in tubes immersed in the fluidized bed. During the pyrolysis phase, which occurs at temperatures between 600 and 850°C, the reactor is fluidized with steam or recycled producer gas rather than air. Heat stored in the phase change material is released during this phase of the cycle to support the endothermic reactions of the pyrolysis stage. Because air is not used during the gas-producing phase of the cycle, nitrogen does not dilute the product gas, resulting in relatively high concentrations of hydrogen and carbon monoxide in the producer gas compared to conventional gasifiers. The carbon monoxide, along with steam used to fluidize the reactor, can be shifted to additional hydrogen by the water-gas shift reaction. Objectives in the first year include: • Determine whether switchgrass is a suitable fuel for the ballasted gasifier.
    [Show full text]
  • Lng Flow Calibration Facilities
    LNG FLOW CALIBRATION FACILITIES Oswin Kerkhof, VSL Mijndert van der Beek, VSL Peter Lucas, VSL Maria Mirzaei, VSL Gerard Blom, VSL Gertjan Kok, VSL Keywords: calibration, flow, flowmeter, custody transfer, measurement, uncertainty, accuracy, transport fuel, quality measurement, 1. Introduction Reliable, accurate and commonly agreed measurement methods are a first requirement for the trade of goods. For the large scale LNG distribution chain there is a commonly agreed measurement practice as described in various ISO standards and in the GIIGNL “Custody transfer handbook”. In comparison with other commodities like natural gas or gasoline the total uncertainty on measured energy is very high for LNG. The LNG industry is therefore committed to improve their measurement accuracies to reduce their financial risks and to optimize their mass and energy balances. As an extension of the traditional distribution chain for LNG a new market of professional consumers is developing with LNG as transport fuel. In this case there is no commonly agreed measurement practice and the metrological framework is not yet in place. This will be a showstopper for the roll-out of the LNG as transport fuel because laws will be enforcing protection of (professional) consumers. For small scale LNG the legal metrology framework will lay down requirements on traceability to national standards and will define maximum permissible measurement errors. This is not the case for large scale LNG where the industrial players are assumed to take care of their own business interests. For this reason the development of an LNG calibration facility is a crucial step and urgently required for the development of the small scale LNG distribution chain.
    [Show full text]
  • Field Reference Manual, 2015
    CALIFORNIA DEPARTMENT OF FOOD AND AGRICULTURE DIVISION OF MEASUREMENT STANDARDS FIELD REFERENCE MANUAL 2015 California Code of Regulation Title 4, Division 9 Chapter 1 Tolerances and Specifications for Commercial Weighing and Measuring Devices NIST Handbook 44 Sections 3.30. Liquid-Measuring Devices through 3.39 Hydrogen Gas-Measuring Devices DISCLAIMER This document represents the Division of Measurement Standards’ field manual for enforcing regulations pertaining to weights and measures in California. This field manual is not to be considered as the official Code of Regulations, as published by Barclays Law Publishers. NOTE: Language in Handbook 44 that is not adopted is annotated “[NOT ADOPTED]” in this document. NOTE: Requirements are different than, or in addition to, the requirements of Handbook 44 are included in the appropriate section this document. They are shaded, bordered, and numbered in the 4002 series to differentiate them from the Handbook 44 requirements. To find the latest online version of the California Code of Regulations (CCR) Title 4, Division 9, visit the California Office of Administration Law (OAL) at: http://ccr.oal.ca.gov/linkedslice/default.asp?SP=CCR-1000&Action=Welcome The CCR may also be accessed at http://oal.ca.gov/ by selecting the link Titled “California Code of Regulations” under the list of “Sponsored Links” in the left column on the OAL Home page. For information concerning the contents of this document, please contact the Division of Measurement Standards by e-mail at [email protected]. NIST Handbook 44 (2015 Edition) - Specifications, Tolerances, and Other Technical Requirements for Weighing and Measuring Devices as adopted by the 98th National Conference on Weights and Measures July 2014 is available at: www.nist.gov/pml/wmd/pubs/hb44.cfm 3.30.
    [Show full text]
  • Guidelines for Gas Meters & Manifolds
    Guidelines for Gas Meters & Manifolds * By carefully following attached suggestions, you will help us get your meters set on the first trip and avoid costly delays related to return trips (for which you are being charged $65 per trip). CoServ Gas Engineering (940) 270-7585 For Gas Emergencies or Leaks call: (844) 330-0763 CoServ Gas Meters and Manifolds Builder & Customer Requirements 1) Gas Meter Planning Guidelines a. The size of gas metering and regulating facilities varies widely depending upon the gas-load needs of each residence, business or commercial building. Due to the parameters associated with meter and regulator selection, it is imperative that the Customer, or the Customer’s agent, contact the assigned CoServ Gas representative prior to construction to determine the exact requirements for specific installations, including location and space requirements. Consulting with us early in the process may eliminate the need for changes to the gas metering facilities or gas Main Extensions or relocation of gas risers at a later date with additional delays and expense to Builder or Customer. 2) Meter Selection Criteria a. To assure proper operation, each gas meter must be the proper size and type for the maximum gas demand and required pressure. The maximum gas demand is determined by adding the Btu input ratings of all gas burning devices that may possibly be operating simultaneously. Furnaces, space heaters, water heaters, boilers, pool heaters, fireplace logs, gas clothes dryers, gas lights, and gas generators should be included at their maximum input ratings. b. The type of meter installed can also vary depending upon the Customer’s usage factors, e.g., what type of business, hours of operation, critical operations, etc.
    [Show full text]
  • Sub-Metering of Natural Gas Flexible Flow Measurement Delivers Improved Accuracy and Substantial Savings
    WHITEPAPER Sub-Metering of Natural Gas Flexible Flow Measurement Delivers Improved Accuracy and Substantial Savings by: Scott Rouse, VP Product Management, Sierra Instruments, Inc fter a decade of remarkable growth, This natural gas boom highlights the importance A the United States has become the for utility companies to provide homes, world’s number one producer of natural gas, businesses, and mid-to-large size facilities and its largest consumer, with consumption in with accurate natural gas billing. Traditionally, 2019 at 31 trillion cubic feet. This high growth utility companies have used diaphragm meters rate is expected to continue. For example, to measure natural gas usage, which is then electricity generation using natural gas has charged to customers on their monthly energy increased from 17% to 35% of total electrical bill. Although diaphragm meters are a trusted consumption, and is likely to increase to 50% billing mechanism by utility companies, they by mid-century. may not provide customers with the most accurate natural gas bill. Diaphragm meters have SUB-METERING OF NATURAL GAS WHITEPAPER limitations in natural gas measurement. If the WHAT IS NATURAL GAS? diaphragm meter does not ac curately measure Natural gas is the cleanest burning fossil the natural gas, this can result in utility companies fuel, producing by-products of mostly carbon overcharging customers. dioxide and water vapor. It is used extensively To avoid this problem, many mid-to-large-size in power generation, industrial and commercial facilities use flow meters to sub-meter their applications, and for home utility and heating. natural gas usage to validate the diaphragm Natural gas is primarily a mixture of methane, meters’ readings and more efficiently allocate ethane and propane, but those components energy.
    [Show full text]
  • Performance of a Pilot Scale Biomass Gasification and Producer
    Iowa State University Capstones, Theses and Graduate Theses and Dissertations Dissertations 2010 Performance of a pilot scale biomass gasification and producer gas combustion system using feedstock with controlled nitrogen content Sharan Sethuraman Iowa State University Follow this and additional works at: https://lib.dr.iastate.edu/etd Part of the Mechanical Engineering Commons Recommended Citation Sethuraman, Sharan, "Performance of a pilot scale biomass gasification and producer gas combustion system using feedstock with controlled nitrogen content" (2010). Graduate Theses and Dissertations. 11725. https://lib.dr.iastate.edu/etd/11725 This Thesis is brought to you for free and open access by the Iowa State University Capstones, Theses and Dissertations at Iowa State University Digital Repository. It has been accepted for inclusion in Graduate Theses and Dissertations by an authorized administrator of Iowa State University Digital Repository. For more information, please contact [email protected]. Performance of a pilot scale biomass gasification and producer gas combustion system using feedstock with controlled nitrogen content by Sharan Sethuraman A thesis submitted to the graduate faculty in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE Major: Mechanical Engineering Program of Study Committee: Song-Charng Kong, Major Professor Terrence Meyer Gap Yong Kim Iowa State University Ames, Iowa 2010 ii TABLE OF CONTENTS LIST OF FIGURES ..................................................................................................................................
    [Show full text]
  • Anaerobic Digester / Biogas Operator Guidebook
    EPA 430-B-20-003 Anaerobic Digester/Biogas System Operator Guidebook A Guidebook for Operating Anaerobic Digestion/Biogas Systems on Farms in the United States November 2020 AgSTAR Operator Guidebook PREFACE U.S. EPA AgSTAR Program AgSTAR is a voluntary outreach program that encourages the implementation of anaerobic digestion (AD) projects in the agricultural and livestock sector to reduce methane (CH4) emissions from agricultural residuals including livestock waste. AD projects can be cost-effective mitigation techniques and provide numerous co-benefits to the local communities where they are installed, including environmental, energy, financial, and social sector benefits. AgSTAR is a collaborative program sponsored by the U.S. Environmental Protection Agency (EPA) and the U.S. Department of Agriculture (USDA) that promotes the use of biogas recovery systems to reduce CH4 emissions from livestock waste. As an education and outreach program, AgSTAR disseminates information relevant to livestock AD projects and synthesizes it for stakeholders who implement, enable, or purchase AD projects. The program’s goals are to provide information that helps stakeholders evaluate the appropriateness of an AD project in a specific location, to provide objective information on the benefits and risks of AD projects, and to communicate the status of AD projects in the livestock sector. Through the AgSTAR website (www.epa.gov/agstar) and at public events and other forums, AgSTAR communicates unbiased technical information and helps create a supportive environment for the implementation of livestock AD projects. AgSTAR provides technical input to the USDA Rural Energy for America Program, which provides grant funding for AD systems at farms.
    [Show full text]
  • Industrial Gas Meter with M-Bus for Compressed Air, Natural Gas, Biogas
    Flow Industrial gas meter with M-Bus for compressed air, natural gas, biogas... Compressed air and natural gas meters with M-Bus now also directly from the manufacturer. CS Instruments GmbH & Co. KG was the OEM-manufacturer of the ENDYS AIR compressed air meter with M-Bus from 2010 to the end of 2017. The ENDYS AIR products have been marketed exclusively through Hochhut GmbH, wich now works with another manufacturer. The CS Instruments GmbH & Co. KG now offers the products themselves. The successor product of ENDYS AIR now offers all the possibilities of digitization and is the ideal consumption meter for Industry 4.0. The successor products of the well-known ENDYS AIR company Hochhuth have been metrologically improved and completely revised and in addition to the M-Bus interface also have the following additional outputs or bus systems: • Modbus RTU • Modbus TCP or TCP PoE • Profibus, Profinet • 4..20 mA and pulse • Hard (in preparation) The VA 520, VA 500, VA 550 and VA 570 industrial gas meters with M-Bus are the ideal compressed air meters or consumption meters for natural gas, biogas, methane, nitrogen, argon, carbon dioxide for consumption measurement and flow measurement. VA 520, VA 500, VA 550, VA 570 with M-Bus are ideal for conversion or retrofitting and for new installations of gas meters, com- pressed air meters, flow meters, etc. to existing or new energy management software according to DIN ISO 50001 and DIN ISO 16247 and building management systems. Advantages: • Direct display in Nm3/h, or NI/min and temperature in C° • Calorimetric measuring principle - no additional pressure and temperature measurement necessary • High measurement accuracy ¼ to 3 inches • VA 500 and VA 550 insert version from ½ inch to DN 400 / DN 500 www.cs-instruments.com 1 Flow VA 520 Compressed air meter with M-Bus Display twist able by 180°C e.g.
    [Show full text]
  • Trac 2. CO Meter 3. 4 Mulm-‐Gas Detector
    HyaHsville Volunteer Fire 2epartment Training Gas Meters 7as Meter9s Carried on the Squad 1. Gas-­‐Trac 2. CO Meter 3. 4 Mul5-­‐Gas$Detector$8MiniMax$X4$Mul5$Gas$ Detector) 11/22/09 Gas$Meters$ Ga%*5rac General*@nformaon ,he$Gas$,rac$is$an$instrument that is$capable$of$ detec5ng$combus5ble$gases.$,he$Gas$,rac is factory$calibrated$for$methane$in$the$air.$,he$ alarm$Iill$be$set oJ$Ihen$the$methane$ concentra5on$in$the$air$approaches$20$percent of$ the$loIer$explosive$limit 11/22/09 Gas$Meters$ Most Common 2etectable 7ases • Acetone • Smoke$ • Alcohol$ • Steam$ • Ammonia • Industrial$Solvents$ • BenNene • Uet Fuel$ • Ethane$ • Lacquer$,hinner$ • Ethylene$ • Methane$ • Gasoline$ • Naphtha • Propane$ • Hydrogen$Sul[de$ • Refrigerants$ 11/22/09 Gas$Meters$ 11/22/09 Gas$Meters$ Direcons*/o*Dse 1. ,urn$the$Gas-­‐,rac$on$in$a non-­‐contaminated$ atmosphere$$$ 2. ,he$ready$light should$come$on$to$determine$ that the$meter$is$ready$for$use$ 3. ,he$L.E.D.$labeled$“Slight]$Iill$light Ihen$.1%$of$ the$gas$is$detected.$,he$“Medium]$light Iill$ light Ihen$1%$of$the$gas$is$detected.$,he$ “Alarm]$light Iill$come$on$Ihen$.%$of$the$gas$ is detected. 11/22/09 Gas$Meters$ Direcons*/o*Ds)*EConB.uedF 2.$,o$pinpoint a leak$source_$adjust the$“,icS$Rate]$ control$for$the$sloIest uniform$5cSing$sound.$ ,he$5cS$rate$Iill$then$vary_$corresponding$to$the$ change$in$gas$concentra5on$detected.$,he$5cS$ rate$is$independent of$the$lights$and$alarm_$ Ihich$are$calibrated$to$appropriate$gas$ concentra5ons.$ 11/22/09 Gas$Meters$ CO Meter ,he$C0$Meter$should$be$turned$on$in$an$ uncontaminated$atmosphere.$ ase$common$sense$Ihen$using$the$meter_$if$ people$are$complaining$of$head$aches_$SCMA$ must be$Iorn.$ Donbt rely$on$home$detectors_$as$they$are$not alIays$accurate.$ 11/22/09 Gas$Meters$ CO EIposure Chart EAll 2ata Based on 1 Hour EIposuresF • MNO*334*E3#0ts per*4illion) $no$health$risSc$normal$C0$levels$ COP in$air.
    [Show full text]
  • An Indirect Measurement Method for Gas Consumption of a Diaphragm Gas Meter Based on Gas Pressure Signal Detection
    applied sciences Article An Indirect Measurement Method for Gas Consumption of a Diaphragm Gas Meter Based on Gas Pressure Signal Detection Zhao Han , Xiaoli Wang *, Baochen Jiang and Xiaopeng Chen School of Mechanical, Electrical and Information Engineering, Shandong University, Weihai 264209, China; [email protected] (Z.H.); [email protected] (B.J.); [email protected] (X.C.) * Correspondence: [email protected]; Tel.: +86-138-6302-6640 Received: 19 March 2019; Accepted: 31 May 2019; Published: 18 June 2019 Featured Application: This indirect measurement method can be utilized to improve the remote meter reading technology for gas meter. Abstract: At present, the remote meter reading problem for a large number of existing domestic diaphragm gas meters has not been reliably solved. The diaphragm gas meter uses a physical structure to measure gas consumption, so the main problem of remote meter reading is the digitization of gas consumption. Although it is possible to digitize the consumption data by modifying the internal structure of the gas meter or adding sensors, thereby realizing the function of remote meter reading, the modification process is complicated, the modification cost is high, and manual meter reading can only be used for the existing diaphragm gas meters. For this reason, this paper proposes an indirect measurement method of gas consumption based on gas pressure signal detection. The method can digitalize the metering results of the mechanical diaphragm gas meter and develop a state detection function by analyzing the pressure signal of the outlet of the meter without modifying the internal structure of a meter, thus addressing the key difficulties in the construction of a gas meter remote meter reading system.
    [Show full text]
  • Natural Gas Meter Installations
    Hibbing Public Utilities Policy Number: CUST094gasmeterinstall Date: May 1, 2004 Subject: NATURAL GAS METER INSTALLATIONS General Requirements Gas meters used to measure the quantity of natural gas used by a customer are owned by the HPUC. The HPUC and the customer will jointly determine the location of all natural gas meters. The HPUC will install, set, and maintain the natural gas meter. Only authorized HPUC personnel can set a meter, turn a meter on or off (except in emergencies), connect a meter to the main gas system, o remove a natural gas meter. Residential Natural Gas Installations The location of residential meters will be jointly determined by the HPUC and then customer in accordance with the following guidelines: 1. Meter installations must comply with all local, state, or federal regulations as stipulated in CFR Part 192. 2. Meters will be located in a safe location that is readily accessible for meter reading and repair. 3. Outside meter locations are mandatory. Outside meters will be installed by a meter set bracket. 4. Inside gas meters are prohibited. 5. Meters and associated relief valves will not be closer than 3 feet to any source of ignition such as electric meters, switches, and transformers. 6. Meter locations will avoid water taps, electric facilities, air intake vents, edges of sidewalks, and driveways. 7. Meters must be installed at least 6 inches above finished grade level. Adopted by Commission Action Pg. 2 – Custo94gasmeterinstall Commercial and Industrial Natural Gas Meter Installations 1) Factors that determine the design of a commercial or industrial natural gas meter installation include: a.
    [Show full text]
  • Section 3.33. Hydrocarbon Gas Vapor-Measuring Devices1
    Handbook 44 - 2007 3.33. Hydrocarbon Gas Vapor-Measuring Devices Section 3.33. Hydrocarbon Gas Vapor-Measuring Devices1 A. Application A.1. - This code applies to devices used for the measurement of hydrocarbon gas in the vapor state, such as propane, propylene, butanes, butylenes, ethane, methane, natural gas and any other hydrocarbon gas/air mix. (Amended 1984, 1986, 1988, and 1991) A.2. - This code does not apply to: (a) Liquid-measuring devices used for dispensing liquefied petroleum gases in liquid form (see Sec. 3.32; Code for Liquefied Petroleum Gas and Anhydrous Ammonia Liquid-Measuring Devices). (b) Natural, liquefied petroleum, and manufactured-gas-vapor meters when these are operated in a public utility system. (c) Mass flow meters (see Sec. 3.37. Code for Mass Flow Meters) (Added 1994) A.3. - See also Sec. 1.10; General Code requirements. S. Specifications S.1. Design of Indicating and Recording Elements and of Recorded Representations. S.1.1. Primary Elements. S.1.1.1. General. - A device shall be equipped with a primary indicating element and may also be equipped with a primary recording element. S.1.1.2. Units. - A volume-measuring device shall indicate, and record if equipped to record, its deliveries in terms of cubic meters or cubic feet, or multiple or decimal subdivisions of cubic meters or cubic feet. (Amended 1972 and 1991) S.1.1.3. Value of Smallest Unit. - Volume-Measuring Devices: The value of the smallest unit of indicated delivery, and recorded delivery if the device is equipped to record, shall not exceed: (a) 1 m3 (1000 dm3) (100 ft3) when the maximum rated gas capacity is less than 100 m3/h (10 000 ft3/h); (b) 10 m3 (1000 ft3) when the maximum rated gas capacity is 280 m3/h (10 000 ft3/h) up to, but not including, 1700 m3/h (60 000 ft 3/h); (c) 100 m3 (10 000 ft3) when the maximum rated gas capacity is 1700 m3/h (60 000 ft3/h) or more.
    [Show full text]