Superior Recreational Products

Total Page:16

File Type:pdf, Size:1020Kb

Superior Recreational Products SUPERIOR RECREATIONAL PRODUCTS SHADE• VOLUME ELEVEN PRODUCT GUIDE • Standard Cantilever Shades GREENARCH APARTMENTS Staying protected just got a whole lot cooler. At Superior Recreational Products (SRP), we provide our customers with standard and custom shade structures for nearly every outdoor location. Our line delivers creative solutions and unique designs while providing protection from the sun’s harmful UV rays. Our 20 years of experience allows us to provide the superior shade products you’ve been searching for. CONTENTS OUR TOP FEATURES AND BENEFITS 14 Umbrellas 24 Hip End COASTAL COMMUNITIES BLOCK UV RAYS 28 Sail Our framework can withstand Our shade fabrics block up 34 Cantilever wind gusts of up to 150 mph to 99% of harmful UV rays, with fabric removed. depending on your color. 42 Playgrounds & Cabanas 49 Superior Products 50 Features & Colors LONG LASTING FABRIC STAY COOL 52 Warranty Our UV stabilized fabric is rachel- Depending on the fabric color, knitted and resists fading, abrading, you can reduce the temperature rotting, shrinkage, and unraveling. of your space up to 25 degrees. IT'S EASY TO BUY AND BID BUILDING CODE SUPERDURABLE Ask us about all of our buying Our team of engineers ensure Our Superdurable powder coat is and leasing affiliations. all shade structures meet local paired with zinc-rich primer — a building codes. standard at Superior. Need another reason to buy? Most shades have the option of including our Glide Elbow™, which allows for quick release of the shade's fabric. Learn more on page 50. Bartram Springs Clubhouse JACKSONVILLE, FLORIDA The Bartram Springs community in Jacksonville, Florida boasts many attractive amenities. The community set aside 20 acres of its total 1,025 acres for parks and recreation spaces. Among the amenities included in this are a Junior Olympic-sized pool, a Superior playground, fitness center, and a shaded wading pool. The wading pool is completely shaded with a Superior Hip End shade, providing relief to the young children swimming and their parents. 2 | UMBRELLAS UMBRELLAS | 3 Twin Brooks Golf Course ST. PETERSBURG, FLORIDA The Twin Brooks Golf Course in St. Petersburg, Florida is a 9-hole par three golf course that recently received numerous upgrades. Among the upgrades included a custom 19-bay Dugout Cantilever for their driving range. This cantilever shade, which measures 190 ft. wide, provides sun relief to 19 golfers practicing their swing. 4 | UMBRELLAS UMBRELLAS | 5 Baylor University WACO, TEXAS Baylor University's Hurd Tennis Center features 12 outdoor tennis courts, six of which are championship courts. Overlooking the championship courts is the shaded Bradley R. Hulse Grandstand. Superior provided 15 custom cantilever shades that matched the Baylor University green. Seabrook Island Lake House JOHNS ISLAND, SOUTH CAROLINA Beautiful Seabrook Island is home to many amenities including the Seabrook Beach Club and the Seabrook Island Lake House. Overlooking the Atlantic Ocean, The Sands at the Beach Club features eight of Superior’s Hyperbolic Sail shades in varying dimensions to accommodate for the curved design of the existing pathway. Seabrook loved the Hyperbolic Sails so much, they sought out Superior again for their Lake House, pictured here. The Lake House features sail shades and our Arched Cantilevers. 8 | UMBRELLAS UMBRELLAS | 9 Seminole County Sports Complex SANFORD, FLORIDA The 100-acre Seminole County Sports Complex is home to 15 state- of-the-art athletic fields, batting cages, and walking paths among many other amenities. Superior supplied T-Cantilever shades in various color schemes for spectator seating across all 15 athletic fields. Additionally, we supplied Cantilever Umbrella shades for each field's score keeper and a large sail shade for a picnic area. 10 | UMBRELLAS UMBRELLAS | 1 1 Pet Paradise Resort WESLEY CHAPEL, FLORIDA Pet Paradise Resort is a state-of-the-art facility offering pet boarding and pet daycare for both cats and dogs. Among the numerous amenities that attracts pet parents to Pet Paradise Resort is the play yard, which features a bone-shaped swimming pool and plenty of shade. The resort utilized our hip shades and created a dual-dome that offers over 1,000 ft. of shaded space. 12 | UMBRELLAS UMBRELLAS | 1 3 HIP ENDS UMBRELLAS FLEXIBILITY meets STYLE ALUMINUM FRAME WATERPROOF umbrella options STEEL FRAME WATERPROOF umbrella options Our aluminum frame waterproof umbrellas feature an Our steel frame waterproof umbrellas feature between a approximate 7' eave height, 316 stainless steel 7'–10' eave height and are designed for strong winds. hardware, a marine grade finish, and are wind tested Choose between your choice of marine grade powder to 75 mph. Fabric color options include fabrics in the coat colors and fabric options in the Ferrari 502, Stam Ferrari 502 or Stam 6002 Textured collections. 6002 Textured, or Sunbrella Marine collections. Horizon Umbrella Ideal for any commercial application, the fixed 360° Optional Vista Umbrella position Horizon umbrella is the simplest sun Pivot shade solution. Ideal for shading swimming pools and outdoor dining spaces, our Vista Cantilever provides SHAPES AND SIZES protection without the obstruction of a center post. Easily opened and retracted, it also has a unique optional pivoting feature. Sunset Umbrella Square Rectangle Hexagon Ideal for cafés, pools, and restaurants, the Sunset SHAPES AND SIZES 10’, 12’, 13’ 10’ x 13’ 14’, 16’, 18’ umbrella can be effortlessly opened and retracted. OPTIONS, FEATURES, AND FABRIC SHAPES AND SIZES Frame Support Upgrade* Square Rectangle Hexagon Fixed Position 10’, 12’, 13’, 16' 10’ x 13’ 14’, 16’, 18’ Ferrari 502 Satin or Stam 6002 Textured Square Rectangle Hexagon *Frame support upgrades are needed when standard frames OPTIONS, FEATURES, AND FABRIC are modified causing additional load requirements. 10’, 12’, 13’ 10’ x 13’ 14’, 16’, 18’ Retractable 360° Pivot Upgrade Double Cantilever Upgrade Electrical Access FEATURES AND FABRIC Height Extensions Retractable Retractable and Pivots Ferrari 502 Satin or Stam 6002 Textured Aluminum Supports 7' Eave Height Ferrari 502 Satin or Stam 6002 Textured *SRP does not recommend or warrant the deployment or use of any collapsible umbrella in wind conditions which exceed 45 mph unless where specifically designated and approved in writing by qualified SRP engineers. 16 | UMBRELLAS UMBRELLAS | 1 7 STEEL FRAME WATERPROOF umbrella options STEEL FRAME WATERPROOF umbrella options Fixed Waterproof Umbrella Ideal for any commercial application, the Fixed Waterproof umbrella combines our Glide Elbow™ convenience with waterproof fabric — an umbrella unlike any other. Fixed Waterproof Cantilever Umbrella Waterproof Hypar Umbrella Much like our new Fixed Waterproof umbrella, the Ideal for shading pools and guest areas, our Hypar SHAPES AND SIZES Fixed Waterproof Cantilever umbrella combines our umbrella provides shade with a unique look. Hypar Glide Elbow™ convenience with waterproof fabric — umbrellas feature a low-profile canopy that will not a cantilever unlike any other. obstruct your view. Square Hexagon SHAPES AND SIZES SHAPE AND SIZES 10', 13’, 16' 16’, 18’ OPTIONS, FEATURES, AND FABRIC Square Hexagon Surface or In-Ground Mount Square 8' or 10' Eave Height 10', 13’, 16' 16’, 18’ Fixed Position Glide Elbow™ 10'–16' Wind Rated to 90 MPH OPTIONS, FEATURES, AND FABRIC Ferrari 502 Satin or Stam 6002 Textured Surface or In-Ground Mount FEATURES AND FABRIC 8' or 10' Eave Height Fixed Position Fixed Position Glide Elbow™ 7' Eave Height Wind Rated to 90 MPH Ferrari 502 Satin or Stam 6002 Textured Ferrari 502 Satin or Stam 6002 Textured 18 | UMBRELLAS UMBRELLAS | 1 9 STEEL FRAME WATERPROOF umbrella options TRADITIONAL STEEL FRAME umbrella options TRADITIONAL STEEL FRAME umbrella options Our traditional steel frame umbrellas are available as surface or in-ground mount in 8', 10', or 12' height, with or without Superior's Glide Elbow™. Choose between your choice of marine grade powder coat colors and our Traditional Shade fabrics. Portable Retractable Umbrella Cantilever Umbrella The easy set-up and portability of the Portable The Cantilever's off-centered post allows for Retractable umbrella makes this a great shade the placement of site furnishings without the Retractable Single Post Umbrella solution for any space. interference of a column. Umbrellas represent one of the most economical SHAPES AND SIZES ways of shading spaces and can cover up to nearly SHAPE AND SIZES 600 square feet of space with a single unit. Single Post Umbrellas are available in square, hexagon, or octagon shapes. Square Square Hexagon SHAPES AND SIZES 10’ 8'–20' 8'–27' FEATURES AND FABRIC OPTIONS, FEATURES, AND FABRIC Portable and Retractable Square Hexagon Octagon Surface or In-Ground Mount 330 lb. Steel Frame 8', 10', or 12' Height 8' Eave Height Available in With or Without Glide Elbow™ Available in Wind Rated to 35 MPH 2' Increments Traditional Shade Fabric 2' Increments from 10’–27' Sunbrella Marine from 10’–24' OPTIONS, FEATURES, AND FABRIC Surface or In-Ground Mount 8', 10', or 12' Height With or Without Glide Elbow™ Traditional Shade Fabric 20 | UMBRELLAS Glide Elbow™ availability depends on dimensions and model. UMBRELLAS | 2 1 TRADITIONAL STEEL FRAME umbrella options TRADITIONAL STEEL FRAME umbrella options Dual Column Umbrella Hypar Umbrella Our dual column umbrella is a great solution for Ideal for shading pools and guest areas, our Hypar shading picnic tables, benches, or small gathering umbrella provides shade with a unique look. Hypar
Recommended publications
  • Adobe Corporate Campus Utah, Usa – Structure Becomes the Architecture
    ADOBE CORPORATE CAMPUS UTAH, USA – STRUCTURE BECOMES THE ARCHITECTURE GEOFF S SHARP Senior Project Engineer, Holmes Consulting Group LP SUMMARY Phase one of Adobe Corporation’s new corporate campus is an example of where the thoughtful selection of structural system and construction materials allowed for seamless integration of engineering and architecture. Constructed of post tensioned and conventionally reinforced concrete the office structure showcases what can be achieved when the structure becomes the architecture. At over 200 metres in length and boasting cantilevered frames and a 25 metre “bridge” the use of concrete was essential to the success of this new office building. INTRODUCTION In late 2012, United States based software giant Adobe Corporation moved into their new 28,000 square metre campus in Lehi, Utah. The decision to expand away from their long standing Silicon Valley home required their new facility to make a statement. It needed to attract a new class of outdoors-loving young professionals. Located approximately 50km south of Salt Lake City, the resulting buildings form stage one of their impressive new home on the “Silicon Slopes” of Utah. Challenges included a highly sloped site with significant variation in subsoil conditions and a dual carriage roadway dividing the property. Figure 1 below shows a rendering of the phase one buildings Figure 1 - Phase 1 Adobe Campus Rendering, courtesy of WRNS Studio The lead architects for the project were WRNS Studio of San Francisco with structural engineering delivered through a collaboration between Holmes Culley in San Francisco and Dunn Associates in Salt Lake City. The design process between architect and engineer was very successful due to an open and collaborative approach.
    [Show full text]
  • Cantilever Bridges: the Governor Harry W
    CANTILEVER BRIDGES: THE GOVERNOR HARRY W. NICE MEMORIAL BRIDGE From a technical perspective, cantilever construction of a bridge defines a specific form of support of the bridge rather than a particular bridge type such as the truss or girder. Simply supported bridges are directly supported on piers and abutments, while continuous structures, as developed in both metal and reinforced concrete during the late nineteenth and early twentieth centuries, include spans that are continuous across one or more intermediate supports. By contrast, the cantilever form of support occurs when the support is at one end and the other end of the span is free. Cantilever bridges consist of a series of cantilevered spans including a main span and two anchor spans which flank it (Pennsylvania Historical and Museum Commission, and Pennsylvania Department of Transportation 1986:124). Based on historical research alone, cantilever bridges in Maryland appear to be represented by only one bridge, which may be briefly described in order to provide historic technological context for the evaluation of that bridge, the 1940 Governor Harry W. Nice Memorial Bridge carrying U.S. 301 over the Potomac River. Bridge historian J.A.L. Waddell noted that "the development of the cantilever. did not proceed very far until modern times, when the truss form of structure had become established and when iron and steel constituted the materials of construction" (Waddell 1916:7). Waddell and subsequent technological historians dated the major advent of modern cantilever bridges to the design and construction of the high bridge over the Kentucky River at Dixville in 1876-1877.
    [Show full text]
  • Using a Cmos-Biomems Cantilever Sensor For
    USING A CMOS-BIOMEMS CANTILEVER SENSOR FOR ORCHID VIRUS DETECTION Lu-Hsun Cheng1, Ya-Chun Chang2, Wen-Chi Hu2, Hsin-Hao Liao3, Hann-Huei Tsai3,Ying-Zong Juang3 and Yen-Wen Lu1 1Dept. of Bio-Industrial Mechatronics Engineering, 2Dept. of Plant Pathology & Microbiology, National Taiwan University, Taipei Taiwan, ROC, 3National Chip Implementation Center (CIC), Hsinchu, Taiwan, R.O.C ABSTRACT We present a preliminary study on utilizing cantilever biosensors to detect Odontoglossum ringspot tobamovirus (ORSV) - one of the most prevalent viruses affecting the health of orchids. The cantilever surfaces of the biosensor are immobilized by ORSV-antibody (Ab) as the recognition probe for ORSV detection. Implemented by using commercially available CMOS technology and post-processed for bio-MEMS capability, the biosensors are embedded with piezoresistors, which can realize surface stress changes due to cantilever deflection coming from the specific bioaffinity between the antigen (Ag) and the antibody. The result shows -0.7% and +0.6% resistivity change when ORSV-Ab and ORSV are respectively presented. KEYWORDS: Cantilever, Odontoglossum ringspot tobamovirus, Piezoresistor, CMOS BioMEMS INTRODUCTION Cantilever biosensors have been used as a sensitive and label-free diagnostic platform for malignant disease diagnosis by detecting DNA mismatch or protein biomarkers [1-3]. Figure 1 depicted the schematics of our device that contained an array of cantilevers with imbedded piezoresistors. The detection is normally achieved by modifying the surface of the cantilever with recognition molecules. The specific interaction between the recognition molecules and the target biomarkers generates surface stress and makes the deflection of the cantilever. The deflection, which is normally several nanometers, can be measured using either optical or piezoresistive readouts.
    [Show full text]
  • Basic Structures
    Basic Structures What is a structure? The structure of a building is the part which is responsible for maintaining the original shape of the building under the influence of the forces, loads and other environmental factors to which is subjected. Examples of structural components include: _Steel beams, columnsm roof trusses ans space frames _Reinforced concrete beams, columns, retaining walls and foundations Below picture shows the Lower Manhattan skyline in New York, one of the greatest concentrations of high-rise buildings in the world. Space limitations on the island meant building construction had to proceed upwards rather than outwards, and the presence of solid rock made foundations for these soaring structures feasible. [Image below: Lower Manhattan skyline in New York, USA] Structural understanding The basic function of a structure is to transmit loads from the position of application of the load to the point of support and thus to the foundations in the ground. Any structure must satisfy the following criteria: 01// Aesthetics (it must look nice). 02// Ease of maintenance. 03// Durability. This means that the materials used must be resistant to corrosion, spalling (pieces falling off), chemical attack, rot. 04// Fire resistance. While few materials can completely resist the effects of fire, it is important for a building to resist fire long enough for its occupants to be safely evacuated. [Image below: Roof structure of Quartier 206 shopping mall, Berlin, Germany] Safety and serviceability There are two main requirements of any structure: it must be safe and it must be serviceable. Safe means that the structure should not collapse Serviceability means that the structure should not deform unduly under the effects of defl ection, cracking or vibration.
    [Show full text]
  • Builder's Guide to Trusses
    Table of Contents Roof Construction Techniques: Pro’s and Con’s . 2 Trusses: Special Benefits for Architects and Engineers . 4 Special Benefits for Contractors and Builders . 5 Special Benefits for the Owner. 5 How Does A Truss Work? . 6 Typical Framing Systems. 8 Gable Framing Variations . 11 Hip Set Framing Variations . 13 Additional Truss Framing Options Valley Sets . 15 Piggyback Trusses . 17 Typical Truss Configurations . 18 Typical Truss Shapes. 20 Typical Bearing / Heel Conditions Exterior Bearing Conditions. 21 Crushing at the Heel . 22 Trusses Sitting on Concrete Walls . 22 Top Chord Bearing. 23 Mid-Height Bearing . 23 Leg-Thru to the Bearing. 23 Tail Bearing Tray. 24 Interior Bearing Conditions . 24 Typical Heel Conditions. 25 Optional End Cosmetics Level Return. 25 Nailer . 25 Parapet. 26 Mansard . 26 Cantilever. 26 Stub . 26 Bracing Examples . 27 Erection of Trusses . 29 Temporary Bracing . 30 Checklist for Truss Bracing Design Estimates . 32 Floor Systems . 33 Typical Bearing / Heel Conditions for Floor Trusses Top Chord, Bottom Chord, and Mid-Height Bearing. 34 Interior Bearing Conditions . 35 Ribbon Boards, Strongbacks and Fire Cut Ends . 36 Steel Trusses . 37 Ask Charlie V. 38 Charlie’s Advice on Situations to Watch Out for in the Field. 41 Glossary of Terms. 42 Appendix - References. 48 1 Builders, Architects and Home Owners today have many choices about what to use in roof and floor systems Traditional Stick Framing – Carpenters take 2x6, Truss Systems – in two primary forms: 2x8, 2x10 and 2x12 sticks of lumber to the job • Metal Plate Connected Wood Trusses – site. They hand cut and fit this lumber together Engineered trusses are designed and into a roof or floor system.
    [Show full text]
  • 1 Classical Architectural Vocabulary
    Classical Architectural Vocabulary The five classical orders The five orders pictured to the left follow a specific architectural hierarchy. The ascending orders, pictured left to right, are: Tuscan, Doric, Ionic, Corinthian, and Composite. The Greeks only used the Doric, Ionic, and Corinthian; the Romans added the ‘bookend’ orders of the Tuscan and Composite. In classical architecture the selected architectural order for a building defined not only the columns but also the overall proportions of a building in regards to height. Although most temples used only one order, it was not uncommon in Roman architecture to mix orders on a building. For example, the Colosseum has three stacked orders: Doric on the ground, Ionic on the second level and Corinthian on the upper level. column In classical architecture, a cylindrical support consisting of a base (except in Greek Doric), shaft, and capital. It is a post, pillar or strut that supports a load along its longitudinal axis. The Architecture of A. Palladio in Four Books, Leoni (London) 1742, Book 1, plate 8. Doric order Ionic order Corinthian order The oldest and simplest of the five The classical order originated by the The slenderest and most ornate of the classical orders, developed in Greece in Ionian Greeks, characterized by its capital three Greek orders, characterized by a bell- the 7th century B.C. and later imitated with large volutes (scrolls), a fascinated shaped capital with volutes and two rows by the Romans. The Roman Doric is entablature, continuous frieze, usually of acanthus leaves, and with an elaborate characterized by sturdy proportions, a dentils in the cornice, and by its elegant cornice.
    [Show full text]
  • Design of Reinforced Concrete Bridges
    Design of Reinforced Concrete Bridges CIV498H1 S Group Design Project Instructor: Dr. Homayoun Abrishami Team 2: Fei Wei 1000673489 Jonny Yang 1000446715 Yibo Zhang 1000344433 Chiyun Zhong 999439022 Executive Summary The entire project report consists of two parts. The first section, Part A, presents a complete qualitative description of typical prestressed concrete bridge design process. The second part, Part B, provides an actual quantitative detailed design a prestressed concrete bridge with respect to three different design standards. In particular, the first part of the report reviews the failure of four different bridges in the past with additional emphasis on the De La Concorde Overpass in Laval, Quebec. Various types of bridges in terms of materials used, cross-section shape and structural type were investigated with their application as well as the advantages and disadvantages. In addition, the predominant differences of the Canadian Highway and Bridge Design Code CSA S6-14 and CSA S6-66, as well as AASHTO LRFD 2014 were discussed. After that, the actual design process of a prestressed concrete bridge was demonstrated, which started with identifying the required design input. Then, several feasible conceptual design options may be proposed by design teams. Moreover, the purpose and significance of structural analysis is discussed in depth, and five different typical analysis software were introduced in this section. Upon the completion of structural analysis, the procedure of detailed structure design and durability design were identified, which included the choice of materials and dimensions of individual specimens as well as the detailed design of any reinforcement profile. Last but not least, the potential construction issues as well as the plant life management and aging management program were discussed and presented at the end of the Part A.
    [Show full text]
  • Comparative Design of a Balanced Cantilever Bridge in Java and Eurocode
    The International Journal of Engineering and Science (IJES) || Volume || 10 || Issue || 3 || Series I || Pages || PP 15-33 || 2021 || ISSN (e): 2319-1813 ISSN (p): 20-24-1805 Comparative Design of a Balanced Cantilever Bridge In Java And Eurocode Umeonyiagu I.E. 1, Onwuka F.E.2, Ogbonna N.P3. 1. Department of Civil Engineering, Chukwuemeka Odumegwu Ojukwu University, Uli, Nigeria. 2. Department of Civil Engineering, Chukwuemeka Odumegwu Ojukwu University, Uli, Nigeria. 3. Federal polytechnic Nekede Owerri, Nigeria. --------------------------------------------------------ABSTRACT---------------------------------------------------------------- This research analyzed, designed and detailed balanced cantilever bridges to Euro codes using manual and computer methods. The design was done considering only the superstructure which forms the dynamic element as a load carrying member. A Java based computer program to analyze, design and detail the balanced cantilever bridge was also written. The Java program focused on the design of prestressing cables for box- girder bridges using balanced cantilever method. The program made use of algorithms and visualization techniques. The segments of the bridge ranged from 15 to 48. The maximum number of cables was 819. Also the maximum number of strands was 9822. The maximum bending moment and shear force were 5790000kNm and 44362.5kN respectively. The manual design were done for 100m, 150m 200m 250m and 300m main spans. These results were then compared to the results gotten from the Java computer program. It could be seen that the results of both analyses and designs obtained using manual procedures and computer program were approximately the same. Furthermore, the percentage difference results showed very little or no differences between the various results obtain from both manual and computer program analyses.
    [Show full text]
  • The Typology of the Historical Timber Bridges of Turkey
    Süheyla Yilmaz, Halide Sert. & Nurdan Apaydin, Int. J. of Herit. Archit., Vol. 2, No. 2 (2018) 230–247 THE TYPOLOGY OF THE HISTORICAL TIMBER BRIDGES OF TURKEY SÜHEYLA YILMAZ HALİDE SERT & NURDAN APAYDIN Historical Bridges Division, Department of Structures, General Directorate of Highways, Ankara, Turkey. ABSTRACT Timber was probably the first material used by humans to construct a bridge structure since Neolithic era. The oldest man-made bridges were probably done by laying tree trunks across streams in girder fashion. Later, many timber bridges were built all over the world, using many variants of beams, can- tilevers, trusses and arches. In Turkey, the Hittite Bridge in Ambarlıkaya near Hattuşa, the capital city of the Hittite Empire, today in Çorum Province, is known as the oldest bridge constructed with wooden beams laid across Ambarlıkaya gorge. In Turkey, historical timber bridges belonging to ancient times could not survive till now while only a few belonging to the 19th century are still standing and reflect the materials and construction technologies of the past. Those bridges, therefore, are very valuable and deserve to be discovered in terms of their technical specifications. The present study is an effort to classify the historical timber bridges in Turkey that have survived up until today. To do that, the study has started with literature survey about the historical development and classification of timber bridges throughout the history in the world. By using that knowledge, the historical timber bridges in Turkey were classified in groups depending on their construction technologies. Discovery of the visible and invisible technical features of historical timber bridges has vital importance for transferring that knowl- edge to conservation practitioners for repairs and maintenance of these bridges.
    [Show full text]
  • Basic Aircraft Construction
    CHAPTER 4 AIRCRAFT BASIC CONSTRUCTION INTRODUCTION useless. All materials used to construct an aircraft must be reliable. Reliability minimizes the possibility of Naval aircraft are built to meet certain specified dangerous and unexpected failures. requirements. These requirements must be selected so they can be built into one aircraft. It is not possible for Many forces and structural stresses act on an one aircraft to possess all characteristics; just as it isn't aircraft when it is flying and when it is static. When it is possible for an aircraft to have the comfort of a static, the force of gravity produces weight, which is passenger transport and the maneuverability of a supported by the landing gear. The landing gear absorbs fighter. The type and class of the aircraft determine how the forces imposed on the aircraft by takeoffs and strong it must be built. A Navy fighter must be fast, landings. maneuverable, and equipped for attack and defense. To During flight, any maneuver that causes meet these requirements, the aircraft is highly powered acceleration or deceleration increases the forces and and has a very strong structure. stresses on the wings and fuselage. The airframe of a fixed-wing aircraft consists of the Stresses on the wings, fuselage, and landing gear of following five major units: aircraft are tension, compression, shear, bending, and 1. Fuselage torsion. These stresses are absorbed by each component of the wing structure and transmitted to the fuselage 2. Wings structure. The empennage (tail section) absorbs the 3. Stabilizers same stresses and transmits them to the fuselage.
    [Show full text]
  • Cantilever Type Switch Design
    IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 CANTILEVER TYPE SWITCH DESIGN Gajanan D.Patil1, N. R. Kolhare2, Pradip Bhosale3, A.I.Rokade4 1Assistant Professor, Dept. of Electronics and Tele-Communication, PRMIT&R, Amravati (M.S.), India 2Assistant Professor, Dept. of Electronics and Tele-Communication, GECA, Aurangabad (M.S.), India 3Assistant Professor, Dept. of Electronics and Tele-Communication, SGOI COE, BELHE, A.nagar (M.S.), India 4Assistant Professor, Dept. of Electronics and Tele-Communication, PRMIT&R, Amravati (M.S.), India Abstract This paper deals with the RF (Radio Frequency)-MEMS (Micro-Electro-Mechanical-System) switch design using the coventorware software and its superiority over the existing technologies like PIN Diodes and Field-Effect-Transistors regarding size, power, Isolation and Insertion loss, and graphically how Pull-in voltage affects on the deflection of the switch. Also this paper deals with the fabrication process of the cantilever switch. Keywords: Etching, Sacrificial Layer, Actuation Voltage, Electrostatic Force, RF Switch, PIN Diodes, Stiction, Isolation and Insertion loss. --------------------------------------------------------------------***---------------------------------------------------------------------- 1. INTRODUCTION Table -1: Comparison between various RF Switches Switch Isolatio Insertion Power Switchi Linea RF MEMS Switches are used for make and break contact Type n Loss Consu- ng Time rity between the transmission lines, and
    [Show full text]
  • Signature Redacted
    Structural Systems and Conceptual Design of Cantilevers by Lingxiao Han B.A. Architecture University of California, Berkeley, 2013 Submitted to the Department of Civil and Environmental Engineering in Partial Fulfillment of the Requirements for the Degree of Master of Engineering in Civil and Environmental Engineering at the MA3SACHU-TS,NSTETE OF TEC'HNOLOGY Massachusetts Institute of Technology IN 2014 June 2014 ©2014 Lingxiao Han. All rights reserved RA R IES The author hereby grants MIT permission to reproduce and to distribute publicly paper and electronic copies of this thesis document in whole or in part in any medium now created. known or herpafter Signature redacted Signature of Author: Department of Civil and Environmental Engineering May 9, 2014 Signature redacted Certified by: Pierre Ghisbain Lecturer of Civil and Environmental Engineering Thesis Supervisor Signature redacted Certified by: Jerome. J. Connor Professor of Civil and Environmental Engineering ThesisfA-SupervisqV Signature redacted Accepted by: If *V Heidi M. Neiff Chair, Departmental Committee for Graduate Students Structural Systems and Conceptual Design of Cantilevers by Lingxiao Han Submitted to the Department of Civil and Environmental Engineering on May 9, 2014 in Partial Fulfillment of the Requirements for the Degree of Master of Engineering in Civil and Environmental Engineering ABSTRACT Cantilevers are a popular way to express form and create unique feature spaces. From a design perspective, cantilevers are amazing feats for the built environment, and structurally, present many opportunities. However, conceptual cantilever design can be a difficult task for Architects and Structural Engineers because there are many structural systems or strategies designers could choose to carry loads to supports.
    [Show full text]