Laboratory Ventilation ACH Rates Standards and Guidelines

Total Page:16

File Type:pdf, Size:1020Kb

Laboratory Ventilation ACH Rates Standards and Guidelines Laboratory Ventilation ACH Rates Standards and Guidelines White Paper Series January 3, 2012 Lab Ventilation ACH Rates Standards and Guidelines January 3, 2012 Table of Contents 1.0 Introduction ............................................................................................................................ 2 2.0 Executive Summary ............................................................................................................... 2 3.0 Survey of Applicable Existing Standards and Guidelines ......................................................2 1. US NFPA (National Fire Protection Association) Standard 45 ...............................................2 2. US OSHA (Occupational Safety and Health Administration) Regulations ............................. 3 3. ANSI/AIHA Z9.5 Laboratory Ventilation Standard .................................................................. 3 4. ACGIH Industrial Ventilation Manual ......................................................................................5 5. ASHRAE 62.1 Standard on Ventilation for Acceptable Indoor Air Quality ............................. 5 6. International Mechanical Code (IMC 2009) ............................................................................7 7. ASHRAE HVAC Applications Handbook, Chapter 14/16: Laboratories ................................. 8 8. European Ventilation Code Information ...............................................................................12 4.0 Laboratory Spill Test Performance and Conclusions ...........................................................13 1. Yale Article Published in the Journal of Chemical Health and Safety ..................................13 2. Demand Based Control Study Article Published in the ASHRAE Journal ............................ 14 White Paper Series Page 1 Lab Ventilation ACH Rates Standards and Guidelines January 3, 2012 1.0 Introduction This document provides an overview of current US and European design practices, standards, and regulations regarding laboratory air change rate minimums for dilution ventilation. 2.0 Executive Summary In the US and Europe there are no prescriptive requirements for air change rates in labs other than the ASHRAE 62.1-2010 fresh air requirements for university/college laboratories that corresponds to about 1.2 ACH (.18 cfm/sq. ft or 0.9l/s/m2). In terms of recommended levels, standards are also significantly moving away from the prescribed values of the past to a more performance based approach based on the specific requirements of a given lab space. 3.0 Survey of Applicable Existing Standards and Guidelines The following codes and standards have existing or past sections relating to laboratory air change rates. 1. US NFPA (National Fire Protection Association) Standard 45 The NFPA 45 standard is the US Standard on Fire Protection for Laboratories Using Chemicals. The previous version of this standard, NFPA 45-2004, had no actual requirements on Lab ACHs, although in the non-binding appendix of the standard there were some recommendations relating to lab ACHs that in the past had been sometimes used as a design practice. The text of these recommendations was as follows: A.8.2.2: A minimum ventilation rate for unoccupied laboratories (e.g., nights and weekends) is four room air changes per hour. Occupied laboratories typically operate at rates of greater than eight room air changes per hour, consistent with the conditions of use for the laboratory. It is not the intent of the standard to require emergency or standby power for laboratory ventilation systems. However, this text and any mention of specifying lab ACHs was eliminated in the current NFPA 45 – 2011 standard that just recently issued: A.8.2.2: It is not the intent of this standard to require emergency or standby power for laboratory ventilation systems. The only remaining reference to lab ventilation is as follows which did not change between the 2004 and 2011 versions and does not provide any prescriptive rates: 8.2.2* Laboratory units and laboratory hoods in which chemicals are present shall be continuously ventilated under normal operating conditions. As such with the 2011 version, NFPA is now silent on prescribing any lab air change rates other than to require continuous ventilation. White Paper Series Page 2 Lab Ventilation ACH Rates Standards and Guidelines January 3, 2012 2. US OSHA (Occupational Safety and Health Administration) Regulations OSHA in the US provides little guidance on air change rates for labs. The only reference OSHA has to laboratory air change rates is quite old and is from a document published on January 31, 1990 titled “Occupational Exposures to Hazardous Chemicals in Laboratories; Final Rule” and was published in the Federal Register as 29 CFR Part 1910. This document does not provide any prescriptive rates for minimum air change rates and mainly required the creation of a Chemical Hygiene Plan by employers to document procedures, policies, and work practices to ensure workers would be protected from hazardous substances. The definition of what specifically should be in the plan was left to the employers. A representative example of a Chemical Hygiene Plan that could be used as guidance for an employer to create their own Plan was provided in this document but was specifically marked as being non- mandatory. This non-mandatory plan was extracted from a 1981 book entitled “Prudent Practices for Handling Hazardous Chemicals in Laboratories”. Under “Section C. The Laboratory Facility” the following sections 4(a) and 4(f) are the only sections potentially relevant to lab air change rates: 4. Ventilation (a) General laboratory ventilation. This system should: Provide a source of air for breathing and for input to local ventilation devices (199); it should not be relied on for protection from toxic substances released into the laboratory (198); ensure that laboratory air is continually replaced, preventing increase of air concentrations of toxic substances during the working day (194); direct air flow into the laboratory from non-laboratory areas and out to the exterior of the building (194). (f) Performance. Rate: 4-12 room air changes/hour is normally adequate general ventilation if local exhaust systems such as hoods are used as the primary method of control [194].” The only reference to air change rates as noted above are not mandatory nor are they even recommendations but rather indications of what is normally adequate general ventilation if hoods are used. Additionally, the range is quite broad being 4 to 12 ACH and as written does not really preclude the use of lower rates. 3. ANSI/AIHA Z9.5 Laboratory Ventilation Standard The 2003 version of this standard is the latest published version of this standard. With respect to laboratory air change rates and ventilation the standard does not take a prescriptive approach. The format of this standard is that it has both a requirements section as expressed by the use of “shall”, and a recommended section that provides description and explanation of the requirements plus suggested good practices as expressed by the use of “should.” The text of the relevant sections is as follows: Section 2.1.2 - Volume Flow Rates/Room Ventilation Rate (2003): Requirements: The specific room ventilation rate shall be established or agreed upon by the owner or his/her designee. White Paper Series Page 3 Lab Ventilation ACH Rates Standards and Guidelines January 3, 2012 Recommendations: Since a ventilation system designer cannot know all possible laboratory operations, chemicals to be utilized, and their potential for release of fumes and other toxic agents, one air exchange rate (air changes per hour) cannot be specified that will meet all conditions. Furthermore, air changes per hour is not the appropriate concept for designing contaminant control systems. Contaminants should be controlled at the source. Section 2.1.4 - Dilution Ventilation (2003) Requirements: Dilution ventilation shall be provided to control the buildup of fugitive emissions and odors in the laboratory. Recommendations: Control of hazardous chemicals by dilution alone, in the absence of adequate laboratory chemical hoods, seldom is effective in protecting laboratory users. Because the exhaust from that type of system must be discharged to the outside or treated intensively before being used as return air, these systems usually are not economical for controlling exposure to hazardous materials compared with use of local exhaust hoods. The latest version and content of the ANSI/AIHA Z9.5 standard has been completed, voted on and was approved. It is now in the process of being properly formatted to ANSI requirements and should be published in the first quarter of 2012.The new language of what should be named the Z9.5-2012 standard is similar to the 2003 standard but provides some additional clarification language beyond what the 2003 standard stated as noted below: Section 2.1.2 - Laboratory (Room) Ventilation Rate (2012) Requirements: The specific room ventilation rate shall be established or agreed upon by the owner or his or her designee. Recommendations: Ventilation is a tool for controlling exposure. Contaminants should be controlled at the source. Potential sources should be identified and exposure control devices should be specified as appropriate to control emissions at the source. (See sections 3 and 4) All sources and assumptions should be clearly defined and documented. An air exchange rate (air changes per hour) cannot be specified that will meet all
Recommended publications
  • Ventilation Heat Recovery Ventilation Glazing; Equipment Insulation
    Town of Warner Building Energy Performance Reports Social Services Government Roads Police Fire Waste Material Waste Water Garage 1 2008 Town Building Energy Use 2 4 5 Oil: 4567 gallons Oil: 4057 gallons LP: 5,122 gallons Elec: 20,160KWH Elec: 19,428KWH Elec: 21,120KWH 72KBtu/ft2 57.4KBtu/ft2 48.4KBtu/ft2 3 8 6* LP: 2,033 gallons Oil: 817 gallons Kerosene: 934 gallons Elec: 19,750KWH Elec: 7,290KWH Elec: 18,731KWH 59.6KBtu/ft2 29.4KBtu ft2 45KBtu/ft2 1 Gallons Btu’s Dollars 7 Oil 10,706 1,483MM $32,118 LP: 2200 gallons LP 9,455 861MM $11,555 Oil: 152 gallons Elec: 130,968KWH Elec 237,906 812MM $37,332 Elec: 459KWH *289KBtu/ft2 TOTALS 2,946MM $81,000 33.8KBtu/ft2 2 Town Building 2008 Utility Costs 3 4 2 $17,615 $15,413 $19,081 5 7 6 $7,005 $9,217 $3,869 8 1 $24,500 $658 3 Town Building 2008 Greenhouse Emissions 2 3 4 120,054lbs 104,184lbs 78,508lbs 5 7 6 34,109lbs 39,232lbs 23,379lbs 8 1 121,507lbs 3,712lbs 4 Town Building Air Leakage Rates 6ACH50 8ACH50 .79cfm/ft2shell 1.21cfm/ft2shell Not tested 2 16ACH50 9ACH50 Not tested 1.3cfm/ft2shell .99cfm/ft2shell ACH50 – Air changes per hour at - 50Pa; relative to building volume 1 6ACH50 33 ACH50 .45cfm/ft2shell Cfm/ft2 shell – cubic feet of air per minute relative to surface area of shell 2.22cfm/ft2shell 5 Summary of Prominent De-ficiencies Insulation Heat Recovery Insulation Ventilation Heat Recovery Ventilation Glazing; Equipment insulation Air Sealing Air Sealing Air Sealing Insulation insulation Equipment Insulation Air Sealing Electric Loads glazing AS / HRV insulation 6 Prioritize by
    [Show full text]
  • Colorcoat Renew SC Design Guide
    Uniclass L5141:P41 CI/SfB (41) Nh2 January 2016 Colorcoat Renew SC® Design guide 2 +44 (0) 1244 892199 | www.tatasteelconstruction.com Contents 1. Colorcoat Renew SC® system overview 4 3.4 Other physical solar collector design considerations 15 1.1 Introduction 4 3.4.1 Perforation diameter and pitch 15 1.2 Working principles of Colorcoat Renew SC® 4 3.4.2 Profile options 16 1.3 Benefits of a Colorcoat Renew SC® system 5 3.4.3 Cavity (plenum) 16 1.4 Colorcoat Renew SC® integration 6 3.4.4 Solar collector integration 17 1.4.1 Suitable building types 6 4. Construction 17 2. System performance factors 7 4.1 Requirements and regulations 17 2.1 General design factors 7 4.2 Collector components 17 2.1.1 Solar collector orientation 7 4.3 Typical construction details 18 2.1.2 Collector angle (Tilt) 8 4.4 Fasteners 21 2.1.3 Shading 8 4.5 Maintenance recommendations 21 2.2 Colour selection and influence on performance 9 5. Mechanical and electrical design considerations 22 2.2.1 Guarantee Colorcoat Renew SC® 10 5.1 Building heating and ventilation 3. Collector design and sizing 11 requirements 22 3.1 Building geometry, occupancy and function 11 5.1.1 Intake air quality 22 3.2 Solar collector sizing - description 12 5.2 Relationship between airflow, temperature increase and efficiency 23 3.2.1 Choosing the wall 5.2.1 Temperature rise 23 3.2.2 Determining the volume of the building space to be heated 5.2.2 Wind considerations 24 3.2.3 Determining the volume of air 5.2.3 Transition duct sizing 24 required by the building ventilation system 5.2.4 Pressure drop 24 3.2.4 Determining the optimum balance 5.3 Operating modes 25 of heating and ventilation requirement 5.4 System control and metering 25 3.2.5 Collector sizing guidelines 6.
    [Show full text]
  • Program and Abstracts CONFERENCE COMMITTEE
    ICC 19 San Diego, CA · June 20-23, 2016 P Program and Abstracts CONFERENCE COMMITTEE Conference Chairman Program Committee Dean Johnson Carl Kirkconnell, West Coast Solutions, Jet Propulsion Laboratory, USA USA - Chair Email: [email protected] Mark Zagarola, Creare, USA, - Deputy Chair Conference Co-Chairmen Tonny Benchop, Thales Cryogenics BV, Netherlands Jose Rodriguez Peter Bradley, NIST, USA Jet Propulsion Laboratory, USA Ted Conrad, Raytheon, USA Email: [email protected] Gershon Grossman, Technion, Israel Elaine Lim, Aerospace Corporation, USA Sidney Yuan Jennifer Marquardt, Ball Aerospace, Aerospace Corporation, USA USA Jeff Olson, Lockheed Martin, USA Email : [email protected] John Pfotenhauer, University of Wisconsin – Madison, USA Treasurer Alex Veprik, SCD, Israel Ray Radebaugh Sonny Yi, Aerospace Corporation, USA National Institute of Standards and Technology (NIST), USA ICC Board Email: [email protected] Dean Johnson, JPL, USA-Chairman Ray Radebaugh, NIST, USA – Treasurer Proceedings Co-editors Ron Ross, JPL, USA – Co-Editor Saul Miller Jeff Raab, Retired, USA – Past Chairman Retired Rich Dausman, Cryomech, Inc., USA - Email: icc [email protected] Past Chairman Paul Bailey, University of Oxford, UK Peter Bradley, NIST, USA Ron Ross Martin Crook, RAL, UK Jet Propulsion Laboratory, USA Lionel Duband, CEA, France Email: [email protected] Zhihua Gan, Zhejiang University, China Ali Kashani, Atlas Scientific, USA Takenori Numezawa, National Institute for Program Chair Material Science, Japan Carl Kirkconnell Jeff Olson, Lockheed Martin Space System West Coast Solutions, USA Co., USA Email: [email protected] Limin Qiu, Zhejiang University, China Thierry Trollier, Absolut System SAS, Deputy Program Chair France Mark Zagarola, Creare, USA Mark V.
    [Show full text]
  • Covid-19 Ventilation Faqs
    COVID-19 VENTILATION FAQS Updated July 9, 2021 Limiting COVID-19 transmission in the workplace involves critical elements outlined in the University’s COVID-19 Prevention Plan for the Workplace. Maintaining building systems, including central heating, ventilation, and air conditioning (HVAC) systems, to support safe occupancy is a supplemental effort to the University’s COVID-19 prevention measures. This document contains responses to frequently asked questions from occupants in University facilities. Building coordinators and facility managers may share the responses with occupants as appropriate. Which standards and guidelines does the University follow for maintaining HVAC systems? • American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) o Coronavirus (COVID-19) Response Resources from ASHRAE and Others • Centers for Disease Control and Prevention (CDC) – Ventilation in Buildings • Seattle Mechanical Code / International Mechanical Code • Washington State Department of Labor & Industries o General Coronavirus Prevention Under Stay Home-Stay Healthy Order o COVID-19 Guidance on Ventilation in the Workplace What do I need to know about ventilation in University buildings? UW buildings are typically supplied with a percentage of outside air either via mechanical fans (a mechanical HVAC system), or natural ventilation (e.g., operable windows), dependent on each building and system. Those systems are maintained to provide ventilation and thermal comfort as designed through the following activities: • In most cases, air filters in buildings equipped with central heating, ventilation, and air conditioning (HVAC) systems are rated at MERV-13 or higher as recommended by the CDC and have been inspected and changed per maintenance procedures and schedules. • Building HVAC systems have continued to operate normally during all phases of the pandemic, even while buildings were unoccupied or at reduced occupancy.
    [Show full text]
  • Ventilation for Acceptable Indoor Air Quality
    ANSI/ASHRAE Addendum n to ANSI/ASHRAE Standard 62-2001 Ventilation for Acceptable Indoor Air Quality Approved by the ASHRAE Standards Committee on June 28, 2003; by the ASHRAE Board of Directors on July 3, 2003; and by the American National Standards Institute on January 8, 2004. This standard is under continuous maintenance by a Standing Standard Project Committee (SSPC) for which the Standards Committee has established a documented program for regular publication of addenda or revisions, including procedures for timely, documented, consensus action on requests for change to any part of the standard. The change submittal form, instruc- tions, and deadlines may be obtained in electronic form from the ASHRAE web site, http://www.ashrae.org, or in paper form from the Manager of Standards. The latest edition of an ASHRAE Stan- dard and printed copies of a public review draft may be pur- chased from ASHRAE Customer Service, 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. E-mail: [email protected]. Fax: 404-321- 5478. Telephone: 404-636-8400 (worldwide), or toll free 1-800-527- 4723 (for orders in U.S. and Canada). ©Copyright 2003 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. ISSN 1041-2336 ASHRAE Standard Project Committee 62.1 Cognizant TC: TC 4.3, Ventilation Requirements and Infiltration SPLS Liaison: Fredrick H. Kohloss Andrew K. Persily, Chair* Roger L. Hedrick Walter L. Raynaud* David S. Bulter, Sr., Vice-Chair* Thomas P. Houston* Lisa J. Rogers Leon E. Alevantis* Eli P. Howard, III* Robert S. Rushing* Michael Beaton Ralph T. Joeckel Lawrence J.
    [Show full text]
  • Download-Manager-files/ Manual Italian.Pdf (Accessed on 29 May 2020)
    energies Article Dynamic Analysis of the Natural and Mechanical Ventilation of a Solar Greenhouse by Coupling Controlled Mechanical Ventilation (CMV) with an Earth-to-Air Heat Exchanger (EAHX) Sara Bonuso 1, Simone Panico 2, Cristina Baglivo 1,* , Domenico Mazzeo 3 , Nicoletta Matera 3, Paolo Maria Congedo 1 and Giuseppe Oliveti 3 1 Department of Engineering for Innovation, University of Salento, Via per Arnesano, It-73100 Lecce, Italy; [email protected] (S.B.); [email protected] (P.M.C.) 2 Eurac Research, Institute for Renewable Energies, Viale Druso 1, 39100 Bolzano, Italy; [email protected] 3 Department of Mechanical, Energy and Management Engineering (DIMEG), University of Calabria, P. Bucci Cube 46/C, It-87036 Arcavacata of Rende (CS), Italy; [email protected] (D.M.); [email protected] (N.M.); [email protected] (G.O.) * Correspondence: [email protected]; Tel.: +39-0832-297750 Received: 2 July 2020; Accepted: 16 July 2020; Published: 16 July 2020 Abstract: Greenhouse crops represent a significant productive sector of the agricultural system; one of the main problems to be addressed is indoor air conditioning to ensure thermal well-being of crops. This study focuses on the ventilation analysis of solar greenhouse with symmetrical flat pitched roof and single span located in a warm temperate climate. This work proposes the dynamic analysis of the greenhouse modeled in TRNsys, simultaneously considering different thermal phenomena three-dimensional (3D) shortwave and longwave radiative exchange, airflow exchanges, presence of lamps with their exact 3D position, ground and plant evapotranspiration, and convective heat transfer coefficients. Several air conditioning systems were analyzed, automatic window opening, controlled mechanical ventilation systems (CMV) and horizontal Earth-to-Air Heat Exchanger (EAHX) coupled with CMV, for different air volume changes per hour.
    [Show full text]
  • Boston University COVID-19 Response Mechanical Ventilation (HVAC) Systems July 28, 2020
    Boston University COVID-19 Response Mechanical Ventilation (HVAC) Systems July 28, 2020 There is limited scientific data concerning the spread of SARS-CoV-2 (COVID-19) through building heating, ventilating and air conditioning (HVAC) systems. The Centers for Disease Control (CDC) describes SARS-CoV-2 infection as occurring primarily from exposure to respiratory droplets from an infected person. Larger droplets from coughing and sneezing are believed to contain more virus than smaller aerosol particles that may be generated by talking, and large droplets settle rapidly before they might enter HVAC systems. The CDC recommends increasing HVAC system ventilation and filtration to reduce the airborne concentration of SARS-CoV-2 if present in smaller droplets in the air as part of a comprehensive program to control the spread of COVID-19 including frequent hands washing, good respiratory etiquette, appropriate social distancing, face coverings, cleaning and disinfecting surfaces, and staying home if sick. CDC guidance for HVAC system operations and maintenance is based on American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) recommendations. BU Heating Ventilating and Air Conditioning (HVAC) COVID-19 Precautions Based on CDC and ASHRAE guidance, Boston University Facilities Management and Operations (FMO) has implemented enhanced maintenance protocols for mechanical and plumbing systems in campus buildings. There are 318 buildings on the Charles River, Fenway and Medical Campuses of which 120 have mechanical ventilation systems and 198 are naturally ventilated using operable windows. Each of the 120 buildings with mechanical ventilation systems is unique in terms of HVAC system design and operation. HVAC systems are designed to meet the state building code and follow American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE) standards.
    [Show full text]
  • ASHRAE EPIDEMIC TASK FORCE SCHOOLS & UNIVERSITIES | Updated 7-15-2020
    ASHRAE EPIDEMIC TASK FORCE SCHOOLS & UNIVERSITIES | Updated 7-15-2020 Introduction New/Modified Facility Design Recommendations Determining Building Readiness • Introduction • Summer Checklist for Fall Classes • Designer Guidelines – General School • Startup Checklist for HVAC Systems Prior to Occupancy • Nurses Office – General Requirements Equipment & System Specific Checks & Verifications During Academic Year Filtration Upgrades • Cleaning & Air Flush • Introduction • Boilers • Filtration Basics • Chilled, Hot & Condenser Water Systems • Filtration Target Level • Air Cooled Chillers • Information Gathering Stage • Water Cooled Chillers • Data Analysis & Review • Cooling Towers & Evaporative-Cooled Devices • Implementation & Considerations • Steam Distribution Systems • HVAC Water Distribution Systems Operation of Occupied Facilities • Pumps Controlling Infection Outbreak in School Facilities • Air Handling Units • Roof Top Units Higher Education Facilities • Unitary & Single Zone Equipment • Student Health Facilities • Laboratories • Athletic Facilities • Residence Facilities • Large Assembly QUESTIONS? [email protected] www.ashrae.org/covid19 Introduction Protecting the health, safety and welfare of the world’s students from the spread of SARS-Cov-2 (the virus that causes COVID-19 disease) is essential to protecting the health, safety and welfare of the entire population. ASHRAE’s position is that “Transmission of SARS-CoV-2 through the air is sufficiently likely that airborne exposure to the virus should be controlled. Changes to building operations, including the operation of heating, ventilating, and air-conditioning [HVAC] systems, can reduce airborne exposures.” There is broad variation of complexity, flexibility, and age in HVAC equipment, systems, controls and Building Automation Systems (BAS) in educational facilities. This guidance has been formulated to help designers retrofit and plan for the improvement of indoor air quality and to slow the transmission of viruses via the HVAC systems.
    [Show full text]
  • OHA 3725 R COVID 19 Public Health Recommendations: Indoor Air
    OFFICE OF THE DIRECTOR Kate Brown, Governor 500 Summer St NE E20 Salem OR 97301 Voice: 503-947-2340 Fax: 503-947-2341 June 30, 2021 COVID-19 Public Health Recommendations: Indoor air considerations for smaller spaces Improved indoor air quality is associated with improved productivity and better health outcomes, regardless of COVID-19. Improvements on those conditions, where needed, will be an investment that can provide benefits extending beyond mitigating infectious disease transmission. Indoor air spaces need special consideration because of COVID-19 transmission potential from the buildup in air of aerosols that we generate from breathing, talking, laughing, shouting, singing, coughing, and sneezing. Maintaining a distance of at least 6 feet between people will help prevent exposure to droplets that we emit, but smaller particles or aerosols can be airborne for minutes to hours depending on ventilation, humidity, and other indoor space factors. Poor ventilation of indoor settings, with larger numbers of people, significantly increases the risk of viral transmission. Below are steps that building managers and property owners can take to improve the indoor air quality in the settings they manage. In general, these steps aim to 1) increase the amount of fresh outside air that is introduced into the system, 2) exhaust air from indoors to the outdoors, and 3) clean the air that is recirculated indoors by using various filtration methods (e.g., HEPA filters) to remove virus-containing particles from the air. Ventilation public health recommendations for indoor spaces • Increase outdoor ventilation of clean air into indoor spaces. • Aim for fewer people in larger rooms.
    [Show full text]
  • Architecture and Energy
    SET 2004 - 3rd International Conference on Sustainable Energy Technologies. Nottingham, UK, 28-30 June 2004 Page 1 of 3 Architecture and energy F. Leal and J. L. Wolpert Faculty of Architecture, Universidad Nacional Autónoma de México ABSTRACT: Architecture, before casting its sublime plastic and aesthetic shed adding to cultural fabric, provides shelter as a response to an aggressive surrounding, as interpreted by human beings. There is then a practical utility in its origin. It follows that a building should operate efficiently to fulfill this primary goal. Architecture is a public art that has its origin in the need for shelter; then it is only caustic for it to consider the environment and energy ratios in its interpretation and to promote a friendly dialogue there too. Keywords: Architecture, energy, comfort INTRODUCTION meteorological characteristics of any site on Earth are What is in Architecture a cultural and artistic the result of an entropic spenditure of some kind of manifestation is born of the duality: man’s need for energy i.e. solar, eolic, chemical or hydrological. protection and the sign of human congregation. Le Corbusier defined at some point Architecture as the ENERGY IN ARCHITECTURE wise game of volumes under light. Later and as a So energy is at the core of Architecture’s primordial result of his social views he dictated: A house is a raison d’etre. This explains why any project needs to machine for human operation. Both visions, although based upon a thorough analysis of the site. An contrasting, hide certain nostalgia of men for their architect must understand what energy and its work and immortality.
    [Show full text]
  • HVAC Design – Industrial Ventilation a Suncam Online Continuing Education Course
    100.pdf HVAC Design Industrial Ventilation by R. Michael Ballew, PE The Free Excel spreadsheets that accompany this course will be included with the final document that you receive when you purchase the course. The links in this course preview document are to nonfunctioning illustrations of those spreadsheets only. 100.pdf HVAC Design – Industrial Ventilation A SunCam online continuing education course Introduction This course is intended for mechanical engineers who want to learn more about Industrial Ventilation. This course qualifies for one (1) hour Professional Engineering CEU credit. Industrial ventilation design issues covered include refrigeration machine room ventilation, battery room ventilation, and warehouse ventilation & heating. Included free with this course are industrial ventilation Excel spreadsheets which are yours to keep and use. Upon completion of this course, you will have a thorough understanding of the design aspects related to industrial ventilation. Machine Rooms Machine rooms, as they are referred to in the building code, are rooms which contain refrigeration equipment such as water chillers, ammonia compressors, or other mechanical refrigeration equipment. The ventilation requirements for machine rooms are governed by building codes such as the International Mechanical Code, the California Mechanical Code, and the Florida Mechanical Code. Insurance provider FM (Factory Mutual) and standards organizations such as ASHRAE (American Society of Heating, Refrigerating, and Air Conditioning Engineers) and IIAR (International Institute of Ammonia Refrigeration) also have a bearing on machine room ventilation. Machine room ventilation serves two purposes; the primary purpose of machine room ventilation is to ensure that the concentration of any leaked refrigerant does not rise above dangerous levels.
    [Show full text]
  • Air Changes Per Hour (ACH) - an Expression of Ventilation Rates - the Number of Times in an Hour That a Home's Entire Air Volume Is Exchanged with Outside Air
    Glossary Air Changes per Hour (ACH) - An expression of ventilation rates - the number of times in an hour that a home's entire air volume is exchanged with outside air. Air Barrier - Meets ASTM E283 A layer of material resistant to air flow usually in the form of polyolefin (i.e. Typar, Tyvek, and other housewraps). A material which is applied in conjunction with a building component (such as a wall, ceiling or sill plate) to prevent the movement of air through that component. Air Barrier System - The assembly of components used in building construction to create a plane of air tightness throughout the building envelope and to control air leakage. Blower Door - Diagnostic equipment consisting of a calibrated fan, removable panel and gauges, used to measure and locate air leaks. Blowing Agent - A gas or a substance capable of producing a refrigerant gas used in making foamed materials. Btu British Thermal Unit - The amount of energy that is required to raise 1 lb. of water up 1° F. Btuh - A rate of energy transfer - can be expressed as Btu's/hour. Building Envelope - The external elements walls which includes, floor, ceiling, roof, windows and doors of a building that encloses conditioned space; the building shell. Capillary Action - The movement of liquid within a material against gravity as a result of surface tension. CFC (Chlorofluorocarbon) - Any of various halocarbon compounds consisting of carbon, hydrogen, chlorine, and fluorine, once used widely as aerosol propellants and refrigerants. Chlorofluorocarbons are believed to cause depletion of the atmospheric ozone layer. Combustion Efficiency - A measure of useful heat extracted from a fuel source by an operating heating appliance.
    [Show full text]