Instructions for Intellivue Patient Monitors

Total Page:16

File Type:pdf, Size:1020Kb

Instructions for Intellivue Patient Monitors ,QVWUXFWLRQVIRU8VH ,QWHOOL9XH3DWLHQW0RQLWRU 0; 5HOHDVH1ZLWK6RIWZDUH5HYLVLRQ1[[[ 3DWLHQW0RQLWRULQJ 2 &RQWHQWV ,QWURGXFWLRQ 15 Safety Information 15 Security Information 18 Introducing the Monitor 20 Devices for Acquiring Measurements 21 Operating and Navigating 37 Operating Modes 45 Understanding Screens 46 Viewing Notifications 47 Using the XDS Remote Display 48 Using the Visitors Screen 48 Understanding Profiles 49 Understanding Settings 50 Changing Wave Speeds 52 Freezing Waves 52 Using Labels 53 Entering Measurements Manually 56 Setting Up the Synchronization Output (with MMX or X3 only) 56 Changing Monitor Settings 57 Checking Your Monitor Revision 58 Getting Started 58 Disconnecting from Power 59 Networked Monitoring 59 Using Remote Applications 60 Using the Integrated PC 61 Using Your Monitor with an X2 or X3 in Companion Mode 63 $ODUPV 65 Visual Alarm Indicators 66 Audible Alarm Indicators 67 Acknowledging Alarms 69 Pausing or Switching Off Alarms 70 Alarm Limits 72 Reviewing Alarms 75 Alarm Advisor 76 Latching Alarms 79 Testing Alarms 80 Alarm Behavior at Power On 80 Alarm Recordings 81 3 3DWLHQW$ODUPVDQG,123V 83 Patient Alarm Messages 83 Technical Alarm Messages (INOPs) 90 0DQDJLQJ3DWLHQWVDQG(TXLSPHQW 119 Patient Concepts 119 Equipment Concepts 119 Bed Management with a Hospital Information System 120 Managing Patients 120 Managing Equipment 134 Care Groups 140 Information Center Compatibility 146 (&*$UUK\WKPLD67DQG470RQLWRULQJ 147 Skin Preparation for Electrode Placement 147 Connecting ECG Cables 147 Selecting the Primary and Secondary ECG Leads 147 Checking Paced Mode 148 Understanding the ECG Display 148 Monitoring Paced Patients 149 Changing the Size of the ECG Wave 150 Changing the Minimum QRS Detection Threshold 151 Changing the Volume of the QRS Tone 151 Changing the ECG Filter Settings 151 Choosing EASI or Standard Lead Placement 152 Selecting Positions of Va and Vb Chest Leads (for 6-electrode placement) 152 About ECG Leads 153 ECG Lead Fallback 154 ECG Lead Placements 154 EASI Lead Placement for a 5-Electrode Cable Set 159 Capture 12-Lead 160 ECG and Arrhythmia Alarm Overview 164 Using ECG Alarms 166 ECG Safety Information 167 About Arrhythmia Monitoring 169 Switching Arrhythmia Analysis On and Off 169 Choosing an ECG Lead for Arrhythmia Monitoring 170 Atrial Fibrillation Alarm 170 Aberrantly-Conducted Beats 170 Intermittent Bundle Branch Block 171 Understanding the Arrhythmia Display 171 Arrhythmia Relearning 173 Arrhythmia Alarms 174 About ST Monitoring 179 4 Switching ST or STE On and Off 180 Understanding the ST Display 181 Updating ST Baseline Snippets 182 Recording ST Segments 183 About the ST Measurement Points 183 ST Alarms 185 STE Alarms 185 Viewing ST Maps 186 Viewing STE Maps 189 About QT/QTc Interval Monitoring 190 QT Alarms 193 Switching QT Monitoring On and Off 194 0RQLWRULQJ3XOVH5DWH 195 Entering the Setup Pulse Menu 195 System Pulse Source 195 Switching Pulse On and Off 195 Using Pulse Alarms 196 QRS Tone 197 0RQLWRULQJ5HVSLUDWLRQ5DWH 5HVS 199 Lead Placement for Monitoring Resp 199 Understanding the Resp Display 200 Changing Resp Detection Modes 200 Changing the Size of the Respiration Wave 201 Changing the Speed of the Respiration Wave 201 Using Resp Alarms 201 Changing the Apnea Alarm Delay 202 Resp Safety Information 202 0RQLWRULQJ6S2 203 Nellcor Patents 203 Masimo Patents 203 SpO2 Sensors 204 Applying the Sensor 204 Connecting SpO2 Cables 205 Measuring SpO2 205 SpO2 Signal Quality Indicator (FAST SpO2 only) 206 Assessing a Suspicious SpO2 Reading 206 Changing the Averaging Time 207 Understanding SpO2 Alarms 207 Pleth Wave 211 Perfusion Numeric 211 5 Perfusion Change Indicator (Philips FAST SpO2 and Nellcor OxiMax only) 211 Setting SpO2/Pleth as Pulse Source 212 Setting Up Tone Modulation 212 Setting the QRS Volume 212 Calculating SpO2 Difference 212 0RQLWRULQJZLWK0DVLPRUDLQERZ6(7 213 Masimo Patents 213 Safety Information 213 Alarm Capabilities 218 SpO2 Measurement with Masimo rainbow SET 220 0RQLWRULQJ1%3 229 Introducing the Oscillometric NBP Measurement 229 Preparing to Measure NBP 231 Starting and Stopping Measurements 233 Enabling Automatic Mode and Setting Repetition Time 234 Enabling Sequence Mode and Setting Up The Sequence 235 Choosing the NBP Alarm Source 235 Switching Pulse from NBP On/Off 235 Assisting Venous Puncture 236 Calibrating NBP 236 0RQLWRULQJ7HPSHUDWXUH 237 Making a Temp Measurement 237 Calculating Temp Difference 238 0HDVXULQJ7\PSDQLF7HPSHUDWXUH 239 Thermometer Display and Controls 240 Making a Temperature Measurement 242 Body Reference Sites and Monitor Labels 243 0RQLWRULQJ,QYDVLYH3UHVVXUH 245 Setting up the Pressure Measurement 246 Overview of Calibration Procedures 247 Zeroing the Pressure Transducer 248 Calibrating Reusable Transducers 250 Adjusting the Calibration Factor 252 Displaying a Mean Pressure Value Only 252 Changing the Pressure Wave Scale 252 Optimizing the Waveform 252 Using the Wave Cursor 252 6 Non-Physiological Artifact Suppression 253 Choosing the Pressure Alarm Source 253 Calculating Cerebral Perfusion Pressure 254 Calculating Pulse Pressure Variation 254 Measuring IAP 255 Measuring Pulmonary Artery Wedge Pressure 256 Editing the Wedge 257 Identifying the Pressure Analog Output Connector 258 0RQLWRULQJ&DUGLDF2XWSXW 259 Hemodynamic Parameters 259 Using the C.O. Procedure Window 260 Accessing the Setup C.O. and Setup CCO Menus 262 Entering the HemoCalc Window 262 Measuring C. O. Using the PiCCO Method 262 Measuring C.O. Using the Right Heart Thermodilution Method 266 Documenting C.O. Measurements 269 C.O. Injectate Guidelines 269 C.O./CCO Curve Alert Messages 270 C.O./CCO Prompt Messages 271 C.O./CCO Warning Messages 272 C.O./CCO Safety Information 273 0RQLWRULQJ&DUERQ'LR[LGH 275 Measurement Principles 276 Measuring CO2 using 867040, M3014A, MMX or X2/X3 277 Measuring Microstream CO2 using 867041 or M3015A/B 282 Setting up all CO2 Measurements 283 Understanding the IPI Numeric 285 0HDVXULQJ$QHVWKHWLFDQG5HVSLUDWRU\*DVHV 287 Identifying Gas Analyzer Module Components 288 Water Trap 288 Understanding the Gas Measurement 289 Making Measurements 290 Understanding the Gas Analyzer Display 292 Installing the Water Trap 292 Removing the Water Trap 293 Emptying the Water Trap 294 Water Trap Replacement 295 Changing Settings for the Gas Analyzer 295 Agent Identification 296 MAC Calculation 297 7 Entering Gas Analyzer Standby Mode 300 Zero Calibration 301 Using the Gas Analyzer During a Cardiopulmonary Bypass 301 Gas Analyzer Safety Information 302 0RQLWRULQJ,QWUDYDVFXODU2[\JHQ6DWXUDWLRQ 305 Selecting a Measurement Label 305 Preparing to Monitor with the M1011A SO2 Module 306 Checking Suspicious Values 308 Calculating Oxygen Extraction 308 0RQLWRULQJ((*D((* 309 EEG/aEEG Monitoring Setup 310 Using the EEG Impedance/Montage Window 310 About Compressed Spectral Arrays (CSA) 312 Changing EEG Settings 313 About aEEG 314 EEG Reports 315 EEG Safety Information 315 EEG and Electrical Interference 316 0RQLWRULQJ%,6 317 BIS Monitoring Setup 318 BIS Signal Quality Indicator and EMG Indicator 318 BIS Continuous Impedance Check 319 BIS Sensor Check 319 BIS Window 319 Bilateral BIS Measurements 320 Changing the BIS Smoothing Rate 321 Switching BIS and Individual Numerics On and Off 321 Changing the Scale of the EEG Wave 321 Switching BIS Filters On or Off 321 BIS Safety Information 321 0RQLWRULQJ107 323 Stimulation Modes 324 Preparing to Measure NMT 324 Taking NMT Measurements 326 Changing the NMT Measurement Settings 328 Alarms 329 Understanding NMT Numerics 329 8 *XDUGLDQ(DUO\:DUQLQJ6FRULQJ 331 Understanding Guardian Early Warning Scoring 331 Performing the Scoring Procedure 332 Triggering Scoring Automatically 334 Viewing EWS Trend Data 334 8VLQJD7HOHPHWU\'HYLFHDQGD0RQLWRU 3,,&RQO\ 337 How Can You Combine Devices? 337 Use Models With Telemetry 339 7UHQGV 341 Viewing Trends 341 Setting Up Trends 345 Documenting Trends 348 Trends Databases 349 Screen Trends 349 &DOFXODWLRQV 353 Performing Calculations 354 Viewing Calculations 355 Reviewing Calculations 356 Documenting Calculations 356 +LJK5HVROXWLRQ7UHQG:DYHV 359 Changing the Hi-Res Trend Waves Displayed 359 Hi-Res Trend Wave Scales 359 Hi-Res Trend Waves and OxyCRG 359 Printing Hi-Res Trend Wave Reports 360 Hi-Res Trend Wave Recordings 360 (YHQW6XUYHLOODQFH 361 Levels of Event Surveillance 361 Event Groups 362 Event Episodes 363 Events Pop-Up Keys 363 Event Triggers 364 The Events Database 368 Viewing Events 368 Annotating Events 371 Documenting Events 371 9 3URWRFRO:DWFK 381 SSC Sepsis Protocol 381 5HFRUGLQJ 387 Paper-Strip Recording 387 Electronic Strip Recording 394 *HQHUDWLQJ3DWLHQW5HSRUWV 397 Starting Reports 397 Canceling Reports 399 Checking Report Status and Printing Manually 399 Viewing Reports on the Screen 403 Setting Up Printing and Storage for the Print Database 404 Checking Printer Settings 404 Printing a Test Report 405 Switching Printers On or Off for Reports 405 Dashed Lines on Reports 405 Unavailable Printer: Re-routing Reports 405 Printer Status Messages 406 Sample Report Printouts 407 8VLQJWKH'UXJ&DOFXODWRU 413 Accessing the Drug Calculator 413 Performing Drug Calculations 414 Charting Infusion Progress 416 Using the Titration Table 416 Documenting Drug Calculations 417 ,QWHOOL%ULGJH(& 419 Connecting an External Device 419 Changing Waves and Numerics Displayed 420 Viewing the IntelliBridge Device Data Window 420 Using Screens with External Device Data 420 Alarms/INOPs from External Devices 420 8VLQJ7LPHUV 423 Viewing Timers 423 Timer Setup Pop-up Keys 423 Setting
Recommended publications
  • Data Driven Investigation of Bispectral Index Algorithm
    www.nature.com/scientificreports OPEN Data Driven Investigation of Bispectral Index Algorithm Hyung-Chul Lee, Ho-Geol Ryu, Yoonsang Park , Soo Bin Yoon, Seong Mi Yang, Hye-Won Oh & Chul-Woo Jung Received: 7 January 2019 Bispectral index (BIS), a useful marker of anaesthetic depth, is calculated by a statistical multivariate Accepted: 9 September 2019 model using nonlinear functions of electroencephalography-based subparameters. However, only Published: xx xx xxxx a portion of the proprietary algorithm has been identifed. We investigated the BIS algorithm using clinical big data and machine learning techniques. Retrospective data from 5,427 patients who underwent BIS monitoring during general anaesthesia were used, of which 80% and 20% were used as training datasets and test datasets, respectively. A histogram of data points was plotted to defne fve BIS ranges representing the depth of anaesthesia. Decision tree analysis was performed to determine the electroencephalography subparameters and their thresholds for classifying fve BIS ranges. Random sample consensus regression analyses were performed using the subparameters to derive multiple linear regression models of BIS calculation in fve BIS ranges. The performance of the decision tree and regression models was externally validated with positive predictive value and median absolute error, respectively. A four-level depth decision tree was built with four subparameters such as burst suppression ratio, power of electromyogram, 95% spectral edge frequency, and relative beta ratio. Positive predictive values were 100%, 80%, 80%, 85% and 89% in the order of increasing BIS in the fve BIS ranges. The average of median absolute errors of regression models was 4.1 as BIS value.
    [Show full text]
  • The Bispectral Index Response to Tracheal Intubation Is Similar In
    458 GENERAL ANESTHESIA The bispectral index response to tracheal intuba- tion is similar in normotensive and hypertensive patients [La réponse de l’index bispectral à l’intubation endotrachéale est similaire chez les patients normotendus et hypertendus] Masayasu Nakayama MD,* Hiromichi Ichinose MD,† Shuji Yamamoto MD,† Noriaki Kanaya MD,* Akiyoshi Namiki MD PhD* Purpose: To compare the hemodynamic and bispectral index (BIS) Conclusion : Les patients hypertendus ou non réagissent par la même responses to tracheal intubation in normotensive and hypertensive réaction d’éveil (mesurée par le BIS) à l’intubation endotrachéale mal- patients. gré l’augmentation de la réponse vasopressive chez les hypertendus. Method: Three minutes after induction of anesthesia with thiamy- lal and fentanyl, tracheal intubation was performed in 24 nor- motensive and 22 hypertensive patients. Heart rate (HR), mean arterial pressure (MAP), and BIS were measured every minute. HE bispectral index (BIS), obtained from Results: Tracheal intubation increased HR, MAP, and BIS in both bispectral analysis of the electroencephalo- normotensive and hypertensive patients. The increase in MAP was gram (EEG), reflects the hypnotic compo- significantly greater in hypertensive patients than in normotensive nent of anesthesia.1–3 Previous studies have patients, but there were no differences in HR or BIS in the two T shown that tracheal intubation is associated with groups of patients. increases in BIS as well as heart rate (HR) and blood Conclusion: Patients with and without hypertension exhibit the pressure.4–6 Therefore, intubation is likely to affect same arousal response (as measured by BIS) to tracheal intubation both the hypnotic and antinociceptive components of despite the enhanced vasopressor response in hypertensive anesthesia.
    [Show full text]
  • The Introduction of Bispectral Index (BIS) in Anesthesia Practice
    EDITORIAL VIEW The introduction of bispectral index (BIS) in anesthesia practice Dario Galante, MD, Matteo Melchionda, MD University Department of Anesthesia and Intensive Care University Hospital Ospedali Riuniti, Foggia, Italy Correspondance: Dario Galante, MD, University Department of Anesthesia and Intensive Care, University Hospital Ospedali Riuniti, Foggia (Italy); E-mail: [email protected] SUMMARY During every surgical procedure we must keep the anesthetic level at an appropriate level so that the patient will neither feel pain nor remember the operation. Yet this anesthetic depth must be balanced against the negative effects and consequences of excess anesthetic and the associated potential for delayed wake up. A wide range of monitoring devices allows us to to avoid the risks of pain, unwanted movements, hemodynamic changes as well as awareness. During the past few years processed EEG signals have become available that help gauge the depth of anesthesia by generating a score linked to EEG activity, which becomes depressed as anesthesia deepens. The bispectral index (BIS) represents one of these innovative methods of monitoring in anesthesia, even if more studies are still needed to make it more precise, especially in pediatric patients and neonates where reliability has yet to be well established. Key words: Bispectral index; Neurological monitoring; Awareness; Depth of anesthesia Citation: Galante D, Melchionda M. The introduction of bispectral index (BIS) in anesthesia practice. Anaesth Pain & Intensive Care 2012;16(3):235-236 The Bispectral IndexTM (Aspect Medical Systems Inc., b) It calculates the index of the state of sedation due to Newton, Mass) is a complex EEG parameter that changes induced by anesthetics by an algorithm combines power spectrum analysis, time domain analysis c) It obtains the value that is recorded by means of a and it values their changes over time.
    [Show full text]
  • Bispectral Index Monitoring During General Anesthesia
    Name of Blue Advantage Policy: Bispectral Index Monitoring During General Anesthesia Policy #: 262 Latest Review Date: October 2019 Category: Other Policy Grade: Effective March 14, 2012: Active Policy but no longer scheduled for regular literature reviews and updates. BACKGROUND: Blue Advantage medical policy does not conflict with Local Coverage Determinations (LCDs), Local Medical Review Policies (LMRPs) or National Coverage Determinations (NCDs) or with coverage provisions in Medicare manuals, instructions or operational policy letters. In order to be covered by Blue Advantage the service shall be reasonable and necessary under Title XVIII of the Social Security Act, Section 1862(a)(1)(A). The service is considered reasonable and necessary if it is determined that the service is: 1. Safe and effective; 2. Not experimental or investigational*; 3. Appropriate, including duration and frequency that is considered appropriate for the service, in terms of whether it is: • Furnished in accordance with accepted standards of medical practice for the diagnosis or treatment of the patient’s condition or to improve the function of a malformed body member; • Furnished in a setting appropriate to the patient’s medical needs and condition; • Ordered and furnished by qualified personnel; • One that meets, but does not exceed, the patient’s medical need; and • At least as beneficial as an existing and available medically appropriate alternative. *Routine costs of qualifying clinical trial services with dates of service on or after September 19, 2000 which meet the requirements of the Clinical Trials NCD are considered reasonable and necessary by Medicare. Providers should bill Original Medicare for covered services that are related to clinical trials that meet Medicare requirements (Refer to Medicare National Coverage Determinations Manual, Chapter 1, Section 310 and Medicare Claims Processing Manual Chapter 32, Sections 69.0-69.11).
    [Show full text]
  • Capnography and the Bispectral Index—Their Role in Pediatric Sedation: a Brief Review
    Hindawi Publishing Corporation International Journal of Pediatrics Volume 2010, Article ID 828347, 5 pages doi:10.1155/2010/828347 Review Article Capnography and the Bispectral Index—Their Role in Pediatric Sedation: A Brief Review Maria Sammartino,1 Barbara Volpe,2 Fabio Sbaraglia,1 Rossella Garra,1 and Alessandro D’Addessi3 1 Department of Anesthesia and Intensive Care, Catholic University of Sacred Heart, 00168 Rome, Italy 2 Department of Anesthesia and Intensive Care, General Hospital San Giovanni Calibita, IsolaTiberina, 00186 Rome, Italy 3 Urology Department, Catholic University of Sacred Heart, Policlinico A. Gemelli, Largo F. Vito 1, 00168 Rome, Italy Correspondence should be addressed to Alessandro D’Addessi, [email protected] Received 3 December 2009; Revised 5 June 2010; Accepted 20 July 2010 Academic Editor: Savithiri Ratnapalan Copyright © 2010 Maria Sammartino et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Sedation in children is increasingly emerging as a minimally invasive technique that may be associated with local anaesthesia or diagnostic and therapeutic procedures which do not necessarily require general anaesthesia. Standard monitoring requirements are not sufficient to ensure an effective control of pulmonary ventilation and deep sedation. Capnography in pediatric sedation assesses the effect of different drugs on the occurrence of respiratory failure and records early indicators of respiratory impairment. The Bispectral index (BIS) allows the reduction of dose requirements of anaesthetic drugs, the reduction in the time to extubation and eye opening, and the reduction in the time to discharge.
    [Show full text]
  • Optimizing Bispectral Index (BIS) Use in the Intensive Care Unit: Development of a Procedure and Skill Competency Validation for Critical Care Nurses
    University of North Dakota UND Scholarly Commons Theses and Dissertations Theses, Dissertations, and Senior Projects 8-1-2005 Optimizing Bispectral Index (BIS) Use in the Intensive Care Unit: Development of a Procedure and Skill Competency Validation for Critical Care Nurses Twyla G. Kouba Follow this and additional works at: https://commons.und.edu/theses Recommended Citation Kouba, Twyla G., "Optimizing Bispectral Index (BIS) Use in the Intensive Care Unit: Development of a Procedure and Skill Competency Validation for Critical Care Nurses" (2005). Theses and Dissertations. 3147. https://commons.und.edu/theses/3147 This Independent Study is brought to you for free and open access by the Theses, Dissertations, and Senior Projects at UND Scholarly Commons. It has been accepted for inclusion in Theses and Dissertations by an authorized administrator of UND Scholarly Commons. For more information, please contact [email protected]. OPTIMIZING BISPECTRAL INDEX (BIS) USE IN THE INTENSIVE CARE UNIT: DEVELOPMENT OF A PROCEDURE AND SKILL COMPETENCY VALIDATION FOR CRITICAL CARE NURSES by Twyla G. Kouba Bachelor of Science, University of North Dakota, 2000 An Independent Study Submitted to the Graduate Faculty of the University of North Dakota in partial fulfillment of the requirements for the degree of Master of Science Grand Forks, North Dakota August 2005 FEB 17 2005 TABLE OF CONTENTS CHAPTER I INTRODUCTION.......................................................................................1 Clinical Problem............................................................................
    [Show full text]
  • Bispectral Index Monitoring During General Anesthesia
    Name of Blue Advantage Policy: Bispectral Index Monitoring During General Anesthesia Policy #: 262 Latest Review Date: January 2010 Category: Other Policy Grade: Effective March 14, 2012: Active Policy but no longer scheduled for regular literature reviews and updates. Background: Blue Advantage medical policy does not conflict with Local Coverage Determinations (LCDs), Local Medical Review Policies (LMRPs) or National Coverage Determinations (NCDs) or with coverage provisions in Medicare manuals, instructions or operational policy letters. In order to be covered by Blue Advantage the service shall be reasonable and necessary under Title XVIII of the Social Security Act, Section 1862(a)(1)(A). The service is considered reasonable and necessary if it is determined that the service is: 1. Safe and effective; 2. Not experimental or investigational*; 3. Appropriate, including duration and frequency that is considered appropriate for the service, in terms of whether it is: • Furnished in accordance with accepted standards of medical practice for the diagnosis or treatment of the patient’s condition or to improve the function of a malformed body member; • Furnished in a setting appropriate to the patient’s medical needs and condition; • Ordered and furnished by qualified personnel; • One that meets, but does not exceed, the patient’s medical need; and • At least as beneficial as an existing and available medically appropriate alternative. *Routine costs of qualifying clinical trial services with dates of service on or after September 19, 2000 which meet the requirements of the Clinical Trials NCD are considered reasonable and necessary by Medicare. Providers should bill Original Medicare for covered services that are related to clinical trials that meet Medicare requirements (Refer to Medicare National Coverage Determinations Manual, Chapter 1, Section 310 and Medicare Claims Processing Manual Chapter 32, Sections 69.0-69.11).
    [Show full text]
  • Bispectral Index (Bis) and Correlated Adverse Events in Patients Undergoing Colonoscopies
    AN EVALUATION OF SEDATION LEVEL USING BISPECTRAL INDEX (BIS) AND CORRELATED ADVERSE EVENTS IN PATIENTS UNDERGOING COLONOSCOPIES A thesis presented to the faculty of the Graduate School of Western Carolina University in partial fulfillment of the requirements for the degree of Master of Science in Nursing. By Paula Michelle Grey & Jenna Lee Poziombke Director: Dr. Mark A. Kossick Professor Graduate Anesthesia Simulation Education Coordinator School of Nursing Committee Members: Dr. Mason McDowell, Nursing Dr. Josh Paschke, Anesthesiologist March 2014 ACKNOWLEDGEMENTS We would like to thank our thesis Director, Dr. Mark A. Kossick, and Advisory Committee, Dr. Mason McDowell, and Dr. Josh Paschke, for their assistance, guidance, and support in the development of our thesis. We would also like to thank Dr. Paul Bartels and Lee Crayton for their contributions in analyzing our quantitative data. Additionally, we offer our warmest regards and thanks to our families, especially our husbands, for their support and encouragement throughout this process. TABLE OF CONTENTS List of Tables .................................................................................................................. v List of Figures ................................................................................................................ vi List of Abbreviations/Symbols ...................................................................................... vii Abstract .........................................................................................................................
    [Show full text]
  • Bispectral Index (BIS) Monitoring Level of Consciousness with the Compact Bisx Power Link™
    Bispectral Index (BIS) Monitoring level of consciousness with the compact BISx Power Link™ Philips Bispectral Index (BIS®) The Philips BIS module provides numerics, measurement uses Aspect Medical graphic trends, and high-resolution trends for the following values: Systems’ XP platform technology. • Bispectral Index® It provides depth of consciousness • Electromyographic strength (EMG) and sedation monitoring for use in the • Signal quality indicator • Suppression ratio OR, ICU, and other clinical settings. • EEG waveform A sensor on the patients forehead • Total power translates brain electrical activity into • Spectral Edge Frequency (SEF) • Burst (available only via Extend sensors) a single BIS value, ranging from 0 to 100, with 100 signifying full awareness and BIS measurements are resistant to artifact 0 indicating no brain activity. from electrocautery devices. The algorithm detects and filters interference from EMG. BIS measurements can be arranged on the screen to suit patient Benefits for anesthesia and critical care requirements and user preferences. BIS measurements can help clinicians formulate the precise type and optimal dosages of anesthetic or sedative medication for each patient. BIS monitoring is most widely used in the OR to help: • Regulate anesthetic drug use • Decrease the incidence of post-operative side effects such as nausea and vomiting • Reduce length of stay in the PACU (recovery room) • Prevent intraoperative awareness BIS monitoring can also be useful during outpatient surgery and conscious sedation. Compatibility In the ICU, BIS monitoring has been shown to BIS information reduce recall of unpleasant experiences and provide is displayed objective sedation assessment during: alongside other key parameters on • Mechanical ventilation these Philips patient • Neuromuscular blockade monitors: • Barbiturate coma • IntelliVue MP20 • Bedside procedures and higher with IntelliVue release C and higher Well managed sedation levels in the ICU can also aid • CMS 2002 in ventilator weaning.
    [Show full text]
  • Evaluation of Bispectral Index Time Delay in Response to Anesthesia
    Rev Bras Anestesiol. 2019;69(4):377---382 REVISTA BRASILEIRA DE Publicação Oficial da Sociedade Brasileira de Anestesiologia ANESTESIOLOGIA www.sba.com.br SCIENTIFIC ARTICLE Evaluation of Bispectral Index time delay in response to anesthesia induction: an observational study a,b,∗ a b,c Ana Leitão Ferreira , Joaquim Gabriel Mendes , Catarina Sofia Nunes , b Pedro Amorim a Universidade do Porto, Faculdade de Engenharia, Porto, Portugal b Centro Hospitalar do Porto, Servic¸o de Anestesiologia, Centro de Investigac¸ão Clínica em Anestesiologia, Porto, Portugal c Universidade Aberta, Departamento de Ciências e Tecnologia, Delegac¸ão do Porto, Porto, Portugal Received 27 September 2018; accepted 3 March 2019 Available online 17 May 2019 KEYWORDS Abstract Bispectral index Background and objectives: According to the manufacturer, the Bispectral Index (BIS) has a pro- monitor; cessing time delay of 5---10 s. Studies addressing this have suggested longer delays. We evaluated Depth of anesthesia; the time delay in the Bispectral Index response. Awareness; Methods: Based on clinical data from 45 patients, using the difference between the predicted Time delay and the real BIS, calculated during a fixed 3 minutes period after the moment the Bispec- tral Index dropped below 80 during the induction of general anesthesia with propofol and remifentanil. Results: The difference between the predicted and the real BIS was in average 30.09 ± 18.73 s. Conclusion: Our results may be another indication that the delay in BIS processing may be much longer than stated by the manufacture, a fact with clinical implications. © 2019 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by- nc-nd/4.0/).
    [Show full text]
  • The BIS Pocket Guide
    2636.cvr:2636.cvr 8/22/2007 7:56 PM Page 1 2636.txt:2636.txt.qxd 9/11/2007 8:03 AM Page i Monitoring Consciousness Using the Bispectral IndexTM During Anesthesia A Pocket Guide for Clinicians SECOND EDITION Scott D. Kelley, M. D. Medical Director Aspect Medical Systems 2636.txt:2636.txt.qxd 9/11/2007 8:03 AM Page ii Learning Objectives After reading this guide, the anesthesia clinician will be able to: • Describe the link between anesthetic effect, EEG signals and the BIS Index • Integrate BIS information during induction, maintenance and emergence • Identify special situations which can influence BIS monitoring • Formulate responses to sudden BIS changes occurring during anesthesia • Summarize the evidence-based impact of utilizing BIS monitoring during anesthesia care • Recommend a role for BIS monitoring in a strategy to reduce the risk of awareness • List resources and pathways to access additional clinical support for BIS monitoring This resource is intended for educational purposes only. It is not intended to provide comprehensive or patient-specific clinical practice recommendations for BIS monitoring technology. The clinical choices discussed in this text may or may not be consistent with your own patient requirements, your clinical practice approaches, or guidelines for practice that are endorsed by your institution or practice group. It is the responsibility of each clinician to make his/her own determination regarding clinical practice decisions that are in the best interest of patients. Readers are advised to review the current product information including the Indications for Use currently provided by the manufacturer. Neither the publisher, author, nor Aspect Medical Systems, Inc.
    [Show full text]
  • Guidelines for Monitoring and Management of Pediatric Patients Before, During, and After Sedation for Diagnostic and Therapeutic Procedures Charles J
    Guidelines for Monitoring and Management of Pediatric Patients Before, During, and After Sedation for Diagnostic and Therapeutic Procedures Charles J. Coté, MD, FAAP, Stephen Wilson, DMD, MA, PhD, AMERICAN ACADEMY OF PEDIATRICS, AMERICAN ACADEMY OF PEDIATRIC DENTISTRY The safe sedation of children for procedures requires a systematic approach abstract that includes the following: no administration of sedating medication without the safety net of medical/dental supervision, careful presedation evaluation This document is copyrighted and is property of the American Academy of Pediatrics and its Board of Directors. All authors have filed for underlying medical or surgical conditions that would place the child at conflict of interest statements with the American Academy of increased risk from sedating medications, appropriate fasting for elective Pediatrics. Any conflicts have been resolved through a process approved by the Board of Directors. The American Academy of procedures and a balance between the depth of sedation and risk for those Pediatrics has neither solicited nor accepted any commercial who are unable to fast because of the urgent nature of the procedure, involvement in the development of the content of this publication. a focused airway examination for large (kissing) tonsils or anatomic airway Clinical reports from the American Academy of Pediatrics benefit from expertise and resources of liaisons and internal (AAP) and external abnormalities that might increase the potential for airway obstruction, a clear reviewers. However, clinical reports from the American Academy of understanding of the medication’s pharmacokinetic and pharmacodynamic Pediatrics may not reflect the views of the liaisons or the organizations or government agencies that they represent.
    [Show full text]